Skip to main content

PLATAFORMAS DE PAPEL Y PLASTICO NANOBIOCONJUGADAS PARA APLICACIONES DE DIAGNOSTICO MEJORADAS

MAT2014-52485-P

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D (Excelencia / Generación de Conocimiento)
Call year 2014
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre FUNDACIÓ INSTITUT CATALÀ DE NANOCIÈNCIA I NANOTECNOLOGIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 30
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Nanopaper as an optical sensing platform

  • Morales-Narváez, Eden
  • Merkoçi, Arben
Bacterial cellulose nanopaper (BC) is a multifunctional material known for numerous desirable properties: sustainability, biocompatibility, biodegradability, optical transparency, thermal properties, flexibility, high mechanical strength, hydrophilicity, high porosity, broad chemical-modification capabilities and high surface area. Herein, we report various nanopaper-based optical sensing platforms and describe how they can be tuned, using nanomaterials, to exhibit plasmonic or photoluminescent properties that can be exploited for sensing applications. We also describe several nanopaper configurations, including cuvettes, plates and spots that we printed or punched on BC. The platforms include a colorimetric-based sensor based on nanopaper containing embedded silver and gold nanoparticles; a photoluminescent-based sensor, comprising CdSe@ZnS quantum dots conjugated to nanopaper; and a potential up-conversion sensing platform constructed from nanopaper functionalized with NaYF4:Yb3+@Er3+&SiO2 nanoparticles. We have explored modulation of the plasmonic or photoluminescent properties of these platforms using various model biologically relevant analytes. Moreover, we prove that BC is and advantageous preconcentration platform that facilitates the analysis of small volumes of optically active materials (∼4 μL). We are confident that these platforms will pave the way to optical (bio)sensors or theranostic devices that are simple, transparent, flexible, disposable, lightweight, miniaturized and perhaps wearable., This work was supported by MINECO (Spain, MAT2014-52485-P, BIO2013-49464-EXP). ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Detection of parathyroid hormone-like hormone in cancer cell cultures by gold nanoparticle-based lateral flow immunoassays

  • Chamorro-García, Alejandro
  • Escosura-Muñiz, Alfredo de la
  • Espinoza-Castañeda, Marisol
  • Rodríguez-Hernández, Carlos J.
  • Torres, Carmen de
  • Merkoçi, Arben
Parathyroid hormone-like hormone (PTHLH) exerts relevant roles in progression and dissemination of several tumors. However, factors influencing its production and secretion have not been fully characterized. The main limitation is the lack of specific, sensitive and widely available techniques to detect and quantify PTHLH. We have developed a lateral flow immunoassay using gold nanoparticles label for the fast and easy detection of PTHLH in lysates and culture media of three human cell lines (HaCaT, LA-N-1, SK-N-AS). Levels in culture media and lysates ranged from 11 to 20 ng/mL and 0.66 to 0.87 μg/mL respectively. Results for HaCaT are in agreement to the previously reported, whereas LA-N-1 and SK-N-AS have been evaluated for the first time. The system also exhibits good performance in human serum samples. This methodology represents a helpful tool for future in vitro and in vivo studies of mechanisms involved in PTHLH production as well as for diagnostics., [From the Clinical Editor]: Parathyroid Hormone-like Hormone (PTHLH) is known to be secreted by some tumors. However, the detection of this peptide remains difficult. The authors here described their technique of using gold nanoparticles as label for the detection of PTHLH by Lateral-flow immunoassays (LFIAs). The positive results may also point a way to using the same technique for the rapid determination of other relevant cancer proteins., Grant/Funding Support: ICN2 acknowledges support of the Spanish MINECO under Project MAT2014-52485-P and through the Severo Ochoa Centers of Excellence Program under Grant SEV-2013-0295 and from the Secretaria d’Universitats i Recerca del Departament d’Economia i Coneixement de la Generalitat de Catalunya (Grant 2014 SGR 260). The authors also wish to acknowledge funding from the Spanish Ministry of Health (FIS PI14/00040 to CdT), and Fundació Privada Cellex., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Enhanced detection of quantum dots labeled protein by simultaneous bismuth electrodeposition into microfluidic channel

  • Medina-Sánchez, Mariana
  • Miserere, Sandrine
  • Cadevall, Miquel
  • Merkoçi, Arben
In this study, we propose an electrochemical immunoassay into a disposable microfluidic platform, using quantum dots (QDs) as labels and their enhanced detection using bismuth as an alternative to mercury electrodes. CdSe@ZnS QDs were used to tag human IgG as a model protein and detected through highly sensitive stripping voltammetry of the dissolved metallic component (cadmium in our case). The modification of the screen printed carbon electrodes (SPCEs) was done by a simple electrodeposition of bismuth that was previously mixed with the sample containing QDs. A magneto-immunosandwich assay was performed using a micromixer. A magnet placed at its outlet in order to capture the magnetic beads used as solid support for the immunoassay. SPCEs were integrated at the end of the channel as detector. Different parameters such as bismuth concentration, flow rate, and incubation times, were optimized. The LOD for HIgG in presence of bismuth was 3.5 ng/mL with a RSD of 13.2%. This LOD was about 3.3-fold lower than the one obtained without bismuth. Furthermore, the sensitivity of the system was increased 100-fold respect to experiments carried out with classical screen-printed electrodes, both in presence of bismuth., This work was supported by MINECO (Spain, MAT2014–52485–P). ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV–2013–0295) and the supportfrom AGAUR, Generalitat de Catalunya (Grant 2014 SGR260)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Modulation of population density and size of silver nanoparticles embedded in bacterial cellulose via ammonia exposure: visual detection of volatile compounds in a piece of plasmonic nanopaper

  • Heli, B.
  • Morales-Narváez, Eden
  • Golmohammadi, H.
  • Ajji, A.
  • Merkoçi, Arben
The localized surface plasmon resonance exhibited by noble metal nanoparticles can be sensitively tuned by varying their size and interparticle distances. We report that corrosive vapour (ammonia) exposure dramatically reduces the population density of silver nanoparticles (AgNPs) embedded within bacterial cellulose, leading to a larger distance between the remaining nanoparticles and a decrease in the UV-Vis absorbance associated with the AgNP plasmonic properties. We also found that the size distribution of AgNPs embedded in bacterial cellulose undergoes a reduction in the presence of volatile compounds released during food spoilage, modulating the studied nanoplasmonic properties. In fact, such a plasmonic nanopaper exhibits a change in colour from amber to light amber upon the explored corrosive vapour exposure and from amber to a grey or taupe colour upon fish or meat spoilage exposure. These phenomena are proposed as a simple visual detection of volatile compounds in a flexible, transparent, permeable and stable single-use nanoplasmonic membrane, which opens the way to innovative approaches and capabilities in gas sensing and smart packaging., This work was supported by MINECO (Spain, MAT2014-52485-P). ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295). Nanobiosensors and Bioelectronics Group acknowledges the support from Secretaria d’Universitats i Recerca del Departament d’Economia i Coneixement de la Generalitat de Catalunya (2014 SGR 260). B. H. thanks the FRQNT (Quebec, Canada), NSERC (Canada) and the industrial partners of 3SPack Chair Saputo and Prolamina for funding her research stay in Spain and the A. A. 3SPack research theme on smart packaging., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Nanochannels for electrical biosensing

  • Escosura-Muñiz, Alfredo de la
  • Merkoçi, Arben
This review shows the recent trends on the use of both single and array nanochannels for electrical biosensing applications. Some general considerations on the principles of the stochastic sensing, together with an overview about the common routes for nanochannels preparation before focusing on the applications for DNA, protein, virus, toxin and other analytes detection are given. Emerging materials used to obtain nanochannels, such as graphene and its analogues as well as novel systems based on the use of nanoparticles in combination with nanochannels are discussed. Aspects related to the analytical performance of the developed devices are also discussed. Finally prospects for future improvements and applications of this technology are included., We acknowledge the support of the Spanish MINECO under Project MAT2014-52485-P and through the Severo Ochoa Centers of Excellence Program under Grant SEV-2013-0295. The support from Secretaria d'Universitats i Recerca del Departament d'Economia i Coneixement de la Generalitat de Catalunya (Grant 2014 SGR 260) and from the E.C. under FP7-OCEAN 2013.1 contract number 613844 “SMS” are also acknowledged., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Paper-based sensors and assays: a success of the engineering design and the convergence of knowledge areas

  • López-Marzo, Adaris M.
  • Merkoçi, Arben
This review shows the recent advances and state of the art in paper-based analytical devices (PADs) through the analysis of their integration with microfluidics and LOC micro- and nanotechnologies, electrochemical/optical detection and electronic devices as the convergence of various knowledge areas. The important role of the paper design/architecture in the improvement of the performance of sensor devices is discussed. The discussion is fundamentally based on μPADs as the new generation of paper-based (bio)sensors. Data about the scientific publication ranking of PADs, illustrating their increase as an experimental research topic in the past years, are supplied. In addition, an analysis of the simultaneous evolution of PADs in academic lab research and industrial commercialization highlighting the parallelism of the technological transfer from academia to industry is displayed. A general overview of the market behaviour, the leading industries in the sector and their commercialized devices is given. Finally, personal opinions of the authors about future perspectives and tendencies in the design and fabrication technology of PADs are disclosed., A. M. López_Marzo thanks Generalitat of Catalonia for the FI_2010 scholarship awarded for the PhD thesis at UAB (Barcelona). The Nanobiosensors and Bioelectronics Group acknowledges the support from MINECO (project MAT2014- 52485-P and Severo Ochoa Program, Grant SEV-2013-0295) and Secretaria d'Universitats i Recerca del Departament d'Economia i Coneixement de la Generalitat de Catalunya (2014 SGR 260)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Water activated graphene oxide transfer using wax printed membranes for fast patterning of a touch sensitive device

  • Baptista-Pires, Luis
  • Mayorga-Martínez, Carmen C.
  • Medina-Sánchez, Mariana
  • Montón, Helena
  • Merkoçi, Arben
We demonstrate a graphene oxide printing technology using wax printed membranes for the fast patterning and water activation transfer using pressure based mechanisms. The wax printed membranes have 50 μm resolution, longtime stability and infinite shaping capability. The use of these membranes complemented with the vacuum filtration of graphene oxide provides the control over the thickness. Our demonstration provides a solvent free methodology for printing graphene oxide devices in all shapes and all substrates using the roll-toroll automatized mechanism present in the wax printing machine. Graphene oxide was transferred over a wide variety of substrates as textile or PET in between others. Finally, we developed a touch switch sensing device integrated in a LED electronic circuit., This work was supported by The European Commission Program, FP7-OCEAN, SMS Project (613844). ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295). Nanobiosensors and Bioelectronics Group acknowledges Generalitat de Cataluña for SGR support and the authors would like to acknowledge MICINN for funding this project (grant MAT2014-52485-P; grant MAT2011-25870 for BES-2012-056022)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Electrochemically reduced graphene and iridium oxide nanoparticles for inhibition-based angiotensin-converting enzyme inhibitor detection

  • Kurbanoglu, Sevinc
  • Rivas, Lourdes
  • Ozkan, Sibel A.
  • Merkoçi, Arben
In this work, a novel biosensor based on electrochemically reduced graphene oxide and iridium oxide nanoparticles for the detection of angiotensin-converting enzyme inhibitor drug, captopril, is presented. For the preparation of the biosensor, tyrosinase is immobilized onto screen printed electrode by using 1-Ethyl-3-(3-dimethylaminopropyl)-carbodiimide and N-Hydroxysuccinimide coupling reagents, in electrochemically reduced graphene oxide and iridium oxide nanoparticles matrix. Biosensor response is characterized towards catechol, in terms of graphene oxide concentration, number of cycles to reduce graphene oxide, volume of iridium oxide nanoparticles and tyrosinase solution. The designed biosensor is used to inhibit tyrosinase activity by Captopril, which is generally used to treat congestive heart failure. It is an angiotensin-converting enzyme inhibitor that operates via chelating copper at the active site of tyrosinase and thioquinone formation. The captopril detections using both inhibition ways are very sensitive with low limits of detection: 0.019 µM and 0.008 µM for chelating copper at the active site of tyrosinase and thioquinone formation, respectively. The proposed methods have been successfully applied in captopril determination in spiked human serum and pharmaceutical dosage forms with acceptable recovery values., S. Kurbanoglu acknowledges the support given by Ankara University BAP14L0237002 for her PhD thesis project. Nanobiosensors and Bioelectronics Group acknowledges the support from MINECO (project MAT2014-52485-P and Severo Ochoa Program, Grant SEV-2013–0295) and Secretaria d′Universitats i Recerca del Departament d′Economia i Coneixement de la Generalitat de Catalunya (2014 SGR 260)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Biosensors for plant pathogen detection

  • Khater, Mohga
  • Escosura-Muñiz, Alfredo de la
  • Merkoçi, Arben
Infectious plant diseases are caused by pathogenic microorganisms such as fungi, bacteria, viruses, viroids, phytoplasma and nematodes. Worldwide, plant pathogen infections are among main factors limiting crop productivity and increasing economic losses. Plant pathogen detection is important as first step to manage a plant disease in greenhouses, field conditions and at the country boarders. Current immunological techniques used to detect pathogens in plant include enzyme-linked immunosorbent assays (ELISA) and direct tissue blot immunoassays (DTBIA). DNA-based techniques such as polymerase chain reaction (PCR), real time PCR (RT-PCR) and dot blot hybridization have also been proposed for pathogen identification and detection. However these methodologies are time-consuming and require complex instruments, being not suitable for in-situ analysis. Consequently, there is strong interest for developing new biosensing systems for early detection of plant diseases with high sensitivity and specificity at the point-of-care. In this context, we revise here the recent advancement in the development of advantageous biosensing systems for plant pathogen detection based on both antibody and DNA receptors. The use of different nanomaterials such as nanochannels and metallic nanoparticles for the development of innovative and sensitive biosensing systems for the detection of pathogens (i.e. bacteria and viruses) at the point-of-care is also shown. Plastic and paper-based platforms have been used for this purpose, offering cheap and easy-to-use really integrated sensing systems for rapid on-site detection. Beside devices developed at research and development level a brief revision of commercially available kits is also included in this review., We acknowledge support from the Spanish MINECO under Project MAT2014-52485-P and through the Severo Ochoa Centers of Excellence Program under Grant SEV-2013-0295. The support from Secretaria d’Universitats i Recerca del Departament d’Economia i Coneixement de la Generalitat de Catalunya (Grant 2014 SGR 260) is also acknowledged., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Graphene-based biosensors: going simple

  • Morales-Narváez, Eden
  • Baptista-Pires, Luis
  • Zamora-Gálvez, Alejandro
  • Merkoçi, Arben
The main properties of graphene derivatives facilitating optical and electrical biosensing platforms are discussed, along with how the integration of graphene derivatives, plastic, and paper can lead to innovative devices in order to simplify biosensing technology and manufacture easy-to-use, yet powerful electrical or optical biosensors. Some crucial issues to be overcome in order to bring graphene-based biosensors to the market are also underscored., The authors acknowledge the support from H2020-EU (INTCATCH Project, Ref. 689341), MINECO (Spain, MAT2014-52485-P, RTC-2014-2619-7 and Severo Ochoa Program, Grant SEV-2013-0295) and Secretaria d'Universitats i Recerca del Departament d'Economia i Coneixement de la Generalitat de Catalunya (2014 SGR 260)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Graphene-based hybrid for enantioselective sensing applications

  • Zor, Erhan
  • Morales-Narváez, Eden
  • Alpaydin, Sabri
  • Bingol, Haluk
  • Ersoz, Mustafa
  • Merkoçi, Arben
Chirality is a major field of research of chemical biology and is essential in pharmacology. Accordingly, approaches for distinguishing between different chiral forms of a compound are of great interest. We report on an efficient and generic enantioselective sensor that is achieved by coupling reduced graphene oxide with γ-cyclodextrin (rGO/γ-CD). The enantioselective sensing capability of the resulting structure was operated in both electrical and optical mode for of tryptophan enantiomers (D-/L-Trp). In this sense, voltammetric and photoluminescence measurements were conducted and the experimental results were compared to molecular docking method. We gain insight into the occurring recognition mechanism with selectivity toward D- and L-Trp as shown in voltammetric, photoluminescence and molecular docking responses. As an enantioselective solid phase on an electrochemical transducer, thanks to the different dimensional interaction of enantiomers with hybrid material, a discrepancy occurs in the Gibbs free energy leading to a difference in oxidation peak potential as observed in electrochemical measurements. The optical sensing principle is based on the energy transfer phenomenon that occurs between photoexcited D-/L-Trp enantiomers and rGO/γ-CD giving rise to an enantioselective photoluminescence quenching due to the tendency of chiral enantiomers to form complexes with γ-CD in different molecular orientations as demonstrated by molecular docking studies. The approach, which is the first demonstration of applicability of molecular docking to show both enantioselective electrochemical and photoluminescence quenching capabilities of a graphene-related hybrid material, is truly new and may have broad interest in combination of experimental and computational methods for enantiosensing of chiral molecules., This work was supported by TÜBİTAK (113Z664 and BİDEB-2214-A/1059B141400210) and was produced from a part of E. Zor's Ph.D. thesis. Nanobiosensors and Bioelectronics Group acknowledges the support from MINECO (Spain, MAT2014-52485-P and Severo Ochoa Program, Grant SEV-2013-0295) and Secretaria d′Universitats i Recerca del Departament d′Economia i Coneixement de la Generalitat de Catalunya (2014 SGR 260)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Graphene-encapsulated materials: Synthesis, applications and trends

  • Morales-Narváez, Eden
  • Sgobbi, Lívia Florio
  • Spinola Machado, Sergio Antonio
  • Merkoçi, Arben
Graphene-based materials (GBM) are an exceptional type of materials that offer unprecedented application capabilities to the scientific and technologic community. The encapsulation of different materials such as drugs, nanoparticles, polymers, oxides and cells by GBM is leading to outstanding hybrid materials with unprecedented behaviours promising a myriad of advantageous applications, including micro/nanomotors, biosensing platforms, bio/imaging agents, drug delivery systems, potential tumour treatment alternatives, environmental remediation platforms, advanced batteries and novel supercapacitors. We present an overview on graphene-encapsulated materials and their most important synthesis pathways. In addition, we explore the synergistic functionalities provided by these composites and highlight the state-of-the-art related to energy, environmental and bio-applications, among others. Finally, we discuss their challenges and future outlooks., This work was supported by: The European Commission Program, FP7-OCEAN, SMS Project (613844) and MINECO (Spain, MAT2014-52485-P, BIO2013-49464-EXP, RTC-2014-2619-7). ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295). Nanobiosensors and Bioelectronics Group acknowledges the support from Secretaria d’Universitats i Recerca del Departament d’Economia i Coneixement de la Generalitat de Catalunya (2014 SGR 260). The author SASM thanks FAPESP (Proc. No. 2013/17053-0) and CNPq (Proc. No. 302762/2013-2) for the financial support. The author LFS thanks FAPESP (Proc. No. 2012/08750-6 and 2013/20701-3)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Mobile phone-based biosensing: An emerging "diagnostic and communication" technology

  • Quesada-González, Daniel
  • Merkoçi, Arben
In this review we discuss recent developments on the use of mobile phones and similar devices for biosensing applications in which diagnostics and communications are coupled. Owing to the capabilities of mobile phones (their cameras, connectivity, portability, etc.) and to advances in biosensing, the coupling of these two technologies is enabling portable and user-friendly analytical devices. Any user can now perform quick, robust and easy (bio)assays anywhere and at any time. Among the most widely reported of such devices are paper-based platforms. Herein we provide an overview of a broad range of biosensing possibilities, from optical to electrochemical measurements; explore the various reported designs for adapters; and consider future opportunities for this technology in fields such as health diagnostics, safety & security, and environment monitoring., The authors acknowledge MINECO (Spain) for the Severo Ochoa Program (Grant SEV-2013-0295) and project MAT2014-52485-P and support from the Secretaria d′Universitats i Recerca del Departament d′Economia i Coneixement de la Generalitat de Catalunya (2014 SGR 260)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Rapid on-chip apoptosis assay on human carcinoma cells based on annexin-V/quantum dot probes

  • Montón, Helena
  • Medina-Sánchez, Mariana
  • Soler, Joan
  • Chalupniak, Andrzej
  • Nogués, Carme
  • Merkoçi, Arben
Despite all the efforts made over years to study the cancer expression and the metastasis event, there is not a clear understanding of its origins and effective treatment. Therefore, more specialized and rapid techniques are required for studying cell behaviour under different drug-based treatments. Here we present a quantum dot signalling-based cell assay carried out in a segmental microfluidic device that allows studying the effect of anti-cancer drugs in cultured cell lines by monitoring phosphatidylserine translocation that occurs in early apoptosis. The developed platform combines the automatic generation of a drug gradient concentration, allowing exposure of cancer cells to different doses, and the immunolabeling of the apoptotic cells using quantum dot reporters. Thereby a complete cell-based assay for efficient drug screening is performed showing a clear correlation between drug dose and amount of cells undergoing apoptosis., The authors acknowledge the support given by MINECO (Spain, MAT2014-52485-P, MAT2014-57960-C03-3-R and Severo Ochoa Program, Grant SEV-2013-0295) and Secretaria d′Universitats i Recerca del Departament d′Economia i Coneixement de la Generalitat de Catalunya (2014 SGR 260 and 2014 SGR 524)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Nanoparticle/nanochannel based sensing systems for neuroblastoma biomarkers detection on plastic and paper platforms

  • Escosura-Muñiz, Alfredo de la
  • Espinoza-Castañeda, Marisol
  • Chamorro-García, Alejandro
  • Rodríguez-Hernández, Carlos J.
  • Torres, Carmen de
  • Merkoçi, Arben
Resumen del trabajo presentado al VIII International Congress on Analytical Nanoscience and Nanotechnology, celebrado en Barcelona (España) del 3 al 5 de julio de 2017., Neuroblastoma (NB) is a childhood cancer of the peripheral nervous system. It affects 10.2 per million children under 15 years of age, and it is the most frequent type of cancer in the first year of life. Despite all the efforts in new therapies, overall survival rates remaining below 40%. Besides, long term survivors suffer from secondary effects inflicted by current multimodal therapies on their normal, developing organs. In this context, there is an important medical need to develop devices for rapid quantification of circulating markers that allow for the precise evaluation of tumor evolution either spontaneous and/or in response to treatments. Parathyroid Hormone-like Hormone (PTHLH) is a cytokine that exerts relevant roles in normal tissues as well as in the initiation, progression and dissemination of several tumors. PTHLH is identified as a factor responsible for neuroblastomainduced hypercalcemia and it is known that circulating PTHLH is a useful marker to monitor the state of malignant-associated hypercalcemia and the effectiveness of treatment in cancer patients. However, there is a lack of specific, sensitive and widely available techniques to detect and quantify this protein. Methods used in hospitals are based on radioimmunoassays (RIAs), involving time consuming hazardous procedures which require sophisticated and expensive equipment and facilities. So point-of-care biosensors for PTHLH detection are strongly demanded by oncologists. In this context, we present here two different nanobiosensing approaches for the rapid and sensitive determination of PTHLH in physiological samples. The first approach is based on the use of solid-state nanoporous platforms in combination with electrochemical detection on screen-printed electrodes. Immunocomplex formation inside the nanoporous platforms leads to nanochannel blockage, which is electrochemically monitored and related to PTHLH concentration. The second methodology relies in a lateral-flow immunoassay (LFIA) using gold nanoparticle (AuNP) tags. Cell culture medium and cell lysates are evaluated with these systems, giving relevant information for understanding the factors that regulate the production and secretion of this protein by tumor cells, with potential interest for new therapies. PTHLH is also determined in human serum, being this data of great interest for diagnostics and for monitoring the effectiveness of therapies., ICN2 acknowledges support of the Spanish MINECO under projects MAT2014-52485-P and PCIN-2016-066 (“NACANCELL”) and through the Severo Ochoa Centers of Excellence Program under Grant SEV-2013-0295. The Secretaria d’Universitats i Recerca del Departament d’Economia i Coneixement de la Generalitat de Catalunya (Grant 2014 SGR 260) is also acknowledged. The authors also wish to acknowledge funding from the Spanish Ministry of Health (FIS PI14/ 00040 to CdT) and Fundació Privada Cellex., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

In situ monitoring of PTHLH secretion in neuroblastoma cells cultured onto nanoporous membranes

  • Escosura-Muñiz, Alfredo de la
  • Espinoza-Castañeda, Marisol
  • Chamorro-García, Alejandro
  • Rodríguez-Hernández, Carlos J.
  • Torres, Carmen de
  • Merkoçi, Arben
In this work, we propose for the first time the use of anodic aluminum oxide (AAO) nanoporous membranes for in situ monitoring of parathyroid hormone-like hormone (PTHLH) secretion in cultured human cells. The biosensing system is based on the nanochannels blockage upon immunocomplex formation, which is electrically monitored through the voltammetric oxidation of Prussian blue nanoparticles (PBNPs). Models evaluated include a neuroblastoma cell line (SK-N-AS) and immortalized keratinocytes (HaCaT) as a control of high PTHLH production. The effect of total number of seeded cells and incubation time on the secreted PTHLH levels is assessed, finding that secreted PTHLH levels range from approximately 60 to 400 ng/mL. Moreover, our methodology is also applied to analyse PTHLH production following PTHLH gene knockdown upon transient cell transfection with a specific silencing RNA (siRNA). Given that inhibition of PTHLH secretion reduces cell proliferation, survival and invasiveness in a number of tumors, our system provides a powerful tool for the preclinical evaluation of therapies that regulate PTHLH production. This nanoporous membrane – based sensing technology might be useful to monitor the active secretion of other proteins as well, thus contributing to characterize their regulation and function., We acknowledge support from the Spanish MINECO under projects MAT2014-52485-P and PCIN-2016-066 (program Euronanomed 2) and from Secretaria d’Universitats i Recerca del Departament d’Economia i Coneixement de la Generalitat de Catalunya (Grant 2014 SGR 260). This work is also funded by the CERCA Programme/Generalitat de Catalunya. ICN2 is supported by the Severo Ochoa program from Spanish MINECO (Grant no. SEV-2013-0295). CdT's group is supported by the Spanish Ministry of Health (PI14/00040), Euronanomed 2 (AC16/00026), H2020-MSCA-ITN-2015 Marie Curie International Training Network (675228) and Fundació Antonio Cabré., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Graphene-based biosensors, going simple

  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Baptista Pires, Luis Miguel|||0000-0002-2290-6386
  • Zamora Gálvez, Alejandro
  • Merkoçi, Arben|||0000-0003-2486-8085
The main properties of graphene derivatives facilitating optical and electrical biosensing platforms are discussed, along with how the integration of graphene derivatives, plastic, and paper can lead to innovative devices in order to simplify biosensing technology and manufacture easy-to-use, yet powerful electrical or optical biosensors. Some crucial issues to be overcome in order to bring graphene-based biosensors to the market are also underscored.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Biosensors for plant pathogen detection

  • Khater, Mohga
  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Merkoçi, Arben|||0000-0003-2486-8085
Infectious plant diseases are caused by pathogenic microorganisms such as fungi, bacteria, viruses, viroids, phytoplasma and nematodes. Worldwide, plant pathogen infections are among main factors limiting crop productivity and increasing economic losses. Plant pathogen detection is important as first step to manage a plant disease in greenhouses, field conditions and at the country boarders. Current immunological techniques used to detect pathogens in plant include enzyme-linked immunosorbent assays (ELISA) and direct tissue blot immunoassays (DTBIA). DNA-based techniques such as polymerase chain reaction (PCR), real time PCR (RT-PCR) and dot blot hybridization have also been proposed for pathogen identification and detection. However these methodologies are time-consuming and require complex instruments, being not suitable for in-situ analysis. Consequently, there is strong interest for developing new biosensing systems for early detection of plant diseases with high sensitivity and specificity at the point-of-care. In this context, we revise here the recent advancement in the development of advantageous biosensing systems for plant pathogen detection based on both antibody and DNA receptors. The use of different nanomaterials such as nanochannels and metallic nanoparticles for the development of innovative and sensitive biosensing systems for the detection of pathogens (i.e. bacteria and viruses) at the point-of-care is also shown. Plastic and paper-based platforms have been used for this purpose, offering cheap and easy-to-use really integrated sensing systems for rapid on-site detection. Beside devices developed at research and development level a brief revision of commercially available kits is also included in this review.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Rapid on-chip apoptosis assay on human carcinoma cells based on annexin-V/quantum dot probes

  • Montón i Domingo, Helena
  • Medina Sánchez, Mariana|||0000-0001-6149-3732
  • Soler, Joan Antoni
  • Chałupniak, Andrzej
  • Nogués, Carme|||0000-0002-6361-8559
  • Merkoçi, Arben|||0000-0003-2486-8085
Despite all the efforts made over years to study the cancer expression and the metastasis event, there is not a clear understanding of its origins and effective treatment. Therefore, more specialized and rapid techniques are required for studying cell behaviour under different drug-based treatments. Here we present a quantum dot signalling-based cell assay carried out in a segmental microfluidic device that allows studying the effect of anti-cancer drugs in cultured cell lines by monitoring phosphatidylserine translocation that occurs in early apoptosis. The developed platform combines the automatic generation of a drug gradient concentration, allowing exposure of cancer cells to different doses, and the immunolabeling of the apoptotic cells using quantum dot reporters. Thereby a complete cell-based assay for efficient drug screening is performed showing a clear correlation between drug dose and amount of cells undergoing apoptosis.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Mobile phone-based biosensing, An emerging "diagnostic and communication" technology

  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Merkoçi, Arben|||0000-0003-2486-8085
In this review we discuss recent developments on the use of mobile phones and similar devices for biosensing applications in which diagnostics and communications are coupled. Owing to the capabilities of mobile phones (their cameras, connectivity, portability, etc.) and to advances in biosensing, the coupling of these two technologies is enabling portable and user-friendly analytical devices. Any user can now perform quick, robust and easy (bio)assays anywhere and at any time. Among the most widely reported of such devices are paper-based platforms. Herein we provide an overview of a broad range of biosensing possibilities, from optical to electrochemical measurements; explore the various reported designs for adapters; and consider future opportunities for this technology in fields such as health diagnostics, safety & security, and environment monitoring.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanochannels for electrical biosensing

  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Merkoçi, Arben|||0000-0003-2486-8085
This review shows the recent trends on the use of both single and array nanochannels for electrical biosensing applications. Some general considerations on the principles of the stochastic sensing, together with an overview about the common routes for nanochannels preparation before focusing on the applications for DNA, protein, virus, toxin and other analytes detection are given. Emerging materials used to obtain nanochannels, such as graphene and its analogues as well as novel systems based on the use of nanoparticles in combination with nanochannels are discussed. Aspects related to the analytical performance of the developed devices are also discussed. Finally prospects for future improvements and applications of this technology are included.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

In situ monitoring of PTHLH secretion in neuroblastoma cells cultured onto nanoporous membranes

  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Espinoza Castañeda, Marisol
  • Chamorro García, Alejandro|||0000-0003-0953-5848
  • Rodríguez-Hernández, Carlos J.
  • De Torres, Carmen
  • Merkoçi, Arben|||0000-0003-2486-8085
In this work, we propose for the first time the use of anodic aluminum oxide (AAO) nanoporous membranes for in situ monitoring of parathyroid hormone-like hormone (PTHLH) secretion in cultured human cells. The biosensing system is based on the nanochannels blockage upon immunocomplex formation, which is electrically monitored through the voltammetric oxidation of Prussian blue nanoparticles (PBNPs). Models evaluated include a neuroblastoma cell line (SK-N-AS) and immortalized keratinocytes (HaCaT) as a control of high PTHLH production. The effect of total number of seeded cells and incubation time on the secreted PTHLH levels is assessed, finding that secreted PTHLH levels range from approximately 60 to 400 ng/mL. Moreover, our methodology is also applied to analyse PTHLH production following PTHLH gene knockdown upon transient cell transfection with a specific silencing RNA (siRNA). Given that inhibition of PTHLH secretion reduces cell proliferation, survival and invasiveness in a number of tumors, our system provides a powerful tool for the preclinical evaluation of therapies that regulate PTHLH production. This nanoporous membrane - based sensing technology might be useful to monitor the active secretion of other proteins as well, thus contributing to characterize their regulation and function.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanobiosensors in diagnostics

  • Chamorro García, Alejandro|||0000-0003-0953-5848
  • Merkoçi, Arben|||0000-0003-2486-8085
Medical diagnosis has been greatly improved thanks to the development of new techniques capable of performing very sensitive detection and quantifying certain parameters. These parameters can be correlated with the presence of specific molecules and their quantity. Unfortunately, these techniques are demanding, expensive, and often complicated. On the other side, progress in other fields of science and technology has contributed to the rapid growth of nanotechnology. Although being an emerging discipline, nanotechnology has raised huge interest and expectations. Most of the enthusiasm comes from new possibilities and properties of nanomaterials. Biosensors (simple, robust, sensitive, cost-effective) combined with nanomaterials, also called nanobiosensors, are serving as bridge between advanced detection/diagnostics and daily/routine tests. Here we review some of the latest applications of nanobiosensors in diagnostics field.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Graphene-based hybrid for enantioselective sensing applications

  • Zor, Erhan
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Alpaydin, Sabri
  • Bingol, Haluk
  • Ersoz, Mustafa
  • Merkoçi, Arben|||0000-0003-2486-8085
Chirality is a major field of research of chemical biology and is essential in pharmacology. Accordingly, approaches for distinguishing between different chiral forms of a compound are of great interest. We report on an efficient and generic enantioselective sensor that is achieved by coupling reduced graphene oxide with γ-cyclodextrin (rGO/γ-CD). The enantioselective sensing capability of the resulting structure was operated in both electrical and optical mode for of tryptophan enantiomers (D-/L-Trp). In this sense, voltammetric and photoluminescence measurements were conducted and the experimental results were compared to molecular docking method. We gain insight into the occurring recognition mechanism with selectivity toward D- and L-Trp as shown in voltammetric, photoluminescence and molecular docking responses. As an enantioselective solid phase on an electrochemical transducer, thanks to the different dimensional interaction of enantiomers with hybrid material, a discrepancy occurs in the Gibbs free energy leading to a difference in oxidation peak potential as observed in electrochemical measurements. The optical sensing principle is based on the energy transfer phenomenon that occurs between photoexcited D-/L-Trp enantiomers and rGO/γ-CD giving rise to an enantioselective photoluminescence quenching due to the tendency of chiral enantiomers to form complexes with γ-CD in different molecular orientations as demonstrated by molecular docking studies. The approach, which is the first demonstration of applicability of molecular docking to show both enantioselective electrochemical and photoluminescence quenching capabilities of a graphene-related hybrid material, is truly new and may have broad interest in combination of experimental and computational methods for enantiosensing of chiral molecules.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Electrochemically reduced graphene and iridium oxide nanoparticles for inhibition-based angiotensin-converting enzyme inhibitor detection

  • Kurbanoglu, Sevinc|||0000-0002-7079-7604
  • Rivas, Lourdes|||0000-0002-1510-5927
  • Ozkan, Sibel A.
  • Merkoçi, Arben|||0000-0003-2486-8085
In this work, a novel biosensor based on electrochemically reduced graphene oxide and iridium oxide nanoparticles for the detection of angiotensin-converting enzyme inhibitor drug, captopril, is presented. For the preparation of the biosensor, tyrosinase is immobilized onto screen printed electrode by using 1-Ethyl-3-(3-dimethylaminopropyl)-carbodiimide and N-Hydroxysuccinimide coupling reagents, in electrochemically reduced graphene oxide and iridium oxide nanoparticles matrix. Biosensor response is characterized towards catechol, in terms of graphene oxide concentration, number of cycles to reduce graphene oxide, volume of iridium oxide nanoparticles and tyrosinase solution. The designed biosensor is used to inhibit tyrosinase activity by Captopril, which is generally used to treat congestive heart failure. It is an angiotensin-converting enzyme inhibitor that operates via chelating copper at the active site of tyrosinase and thioquinone formation. The captopril detections using both inhibition ways are very sensitive with low limits of detection: 0.019 µM and 0.008 µM for chelating copper at the active site of tyrosinase and thioquinone formation, respectively. The proposed methods have been successfully applied in captopril determination in spiked human serum and pharmaceutical dosage forms with acceptable recovery values.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanomaterials-based enzyme electrochemical biosensors operating through inhibition for biosensing applications

  • Kurbanoglu, Sevinc|||0000-0002-7079-7604
  • Ozkan, Sibel A.
  • Merkoçi, Arben|||0000-0003-2486-8085
In recent years great progress has been made in applying nanomaterials to design novel biosensors. Use of nanomaterials offers to biosensing platforms exceptional optical, electronic and magnetic properties. Nanomaterials can increase the surface of the transducing area of the sensors that in turn bring an increase in catalytic behaviors. They have large surface-to-volume ratio, controlled morphology and structure that also favor miniaturization, an interesting advantage when the sample volume is a critical issue. Biosensors have great potential for achieving detect-to-protect devices: devices that can be used in detections of pollutants and other treating compounds/analytes (drugs) protecting citizens' life. After a long term focused scientific and financial efforts/supports biosensors are expected now to fulfill their promise such as being able to perform sampling and analysis of complex samples with interest for clinical or environment fields. Among all types of biosensors, enzymatic biosensors, the most explored biosensing devices, have an interesting property, the inherent inhibition phenomena given the enzyme-substrate complex formation. The exploration of such phenomena is making remarkably important their application as research and applied tools in diagnostics. Different inhibition biosensor systems based on nanomaterials modification has been proposed and applied. The role of nanomaterials in inhibition-based biosensors for the analyses of different groups of drugs as well as contaminants such as pesticides, phenolic compounds and others, are discussed in this review. This deep analysis of inhibition-based biosensors that employ nanomaterials will serve researchers as a guideline for further improvements and approaching of these devices to real sample applications so as to reach society needs and such biosensor market demands.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Magnetic nanoparticle-molecular imprinted polymer, a new impedimetric sensor for tributyltin detection

  • Zamora Gálvez, Alejandro
  • Mayorga-Martinez, Carmen C.|||0000-0003-3687-0035
  • Parolo, Claudio|||0000-0001-9481-4408
  • Pons Picart, Josefina|||0000-0003-1834-9326
  • Merkoçi, Arben|||0000-0003-2486-8085
Recently, molecular imprinted polymers (MIPs) were extensively used for separation and identification of specific molecules, replacing expensive and unstable biological receptors. Nonetheless, their application in electrochemical sensors has not been sufficiently explored. Here we report the use of a MIP as a specific receptor in a new highly sensitive tributyltin (TBT) electrochemical sensor. The sensor combines the specificity, pre-concentration capability and robustness of molecular imprinted polymer attached onto magnetic nanoparticles with the quantitative outputs of impedimetric measurements. The proposed device detects TBT in a concentration range of 5 pM to 5 μM with a low limit of detection (5.37 pM), which is lower than the one recommended for TBT in sea water by the US Environmental Protection Agency (EPA). We believe that this new electrochemical sensor can play an important role in the monitoring of the quality of sea and fresh waters worldwide.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Highly loaded mildly edge-oxidized graphene nanosheet dispersions for large-scale inkjet printing of electrochemical sensors

  • Nagar, Bhawna|||0000-0003-2363-9758
  • Jović, Milica|||0000-0003-3495-2416
  • Bassetto, Víctor Costa
  • Zhu, Yingdi|||0000-0001-5584-3513
  • Pick, Horst|||0000-0003-1347-0223
  • Gómez-Romero, Pedro|||0000-0002-6208-5340
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Girault, Hubert H.|||0000-0001-5573-5774
  • Lesch, Andreas|||0000-0002-4995-2251
Inkjet printing of electrochemical sensors using a highly loaded mildly edge-oxidized graphene nanosheet (EOGN) ink is presented. An ink with 30 mg/mL EOGNs is formulated in a mixture of N-methyl pyrrolidone and propylene glycol with only 30 min of sonication. The absence of additives, such as polymeric stabilizers or surfactants, circumvents reduced electrochemical activity of coated particles and avoids harsh post-printing conditions for additive removal. A single light pulse from a xenon flash lamp dries the printed EGON film within a fraction of a second and creates a compact electrode surface. An accurate coverage with only 30.4 μg of EOGNs per printed layer and cm is achieved. The EOGN films adhere well to flexible polyimide substrates in aqueous solution. Electrochemical measurements were performed using cyclic voltammetry and differential pulse voltammetry. An all inkjet-printed three-electrode living bacterial cell detector is prepared with EOGN working and counter electrodes and silver-based quasi-reference electrode. The presence of E. coli in liquid samples is recorded with four electroactive metabolic activity indicators.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Modulation of population density and size of silver nanoparticles embedded in bacterial cellulose, via ammonia exposure: visual detection of volatile compounds in a piece of plasmonic nanopaper

  • Heli, B.|||0000-0002-1894-5139
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Golmohammadi, Hamed|||0000-0001-5271-2438
  • Ajji, A.
  • Merkoçi, Arben|||0000-0003-2486-8085
The localized surface plasmon resonance exhibited by noble metal nanoparticles can be sensitively tuned by varying their size and interparticle distances. We report that corrosive vapour (ammonia) exposure dramatically reduces the population density of silver nanoparticles (AgNPs) embedded within bacterial cellulose, leading to a larger distance between the remaining nanoparticles and a decrease in the UV-Vis absorbance associated with the AgNP plasmonic properties. We also found that the size distribution of AgNPs embedded in bacterial cellulose undergoes a reduction in the presence of volatile compounds released during food spoilage, modulating the studied nanoplasmonic properties. In fact, such a plasmonic nanopaper exhibits a change in colour from amber to light amber upon the explored corrosive vapour exposure and from amber to a grey or taupe colour upon fish or meat spoilage exposure. These phenomena are proposed as a simple visual detection of volatile compounds in a flexible, transparent, permeable and stable single-use nanoplasmonic membrane, which opens the way to innovative approaches and capabilities in gas sensing and smart packaging.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Enhanced detection of quantum dots labeled protein by simultaneous bismuth electrodeposition into microfluidic channel

  • Medina Sánchez, Mariana|||0000-0001-6149-3732
  • Miserere, Sandrine|||0000-0003-2311-621X
  • Cadevall Riera, Miquel|||0000-0002-2968-5862
  • Merkoçi, Arben|||0000-0003-2486-8085
In this study, we propose an electrochemical immunoassay into a disposable microfluidic platform, using quantum dots (QDs) as labels and their enhanced detection using bismuth as an alternative to mercury electrodes. CdSe@ZnS QDs were used to tag human IgG as a model protein and detected through highly sensitive stripping voltammetry of the dissolved metallic component (cadmium in our case). The modification of the screen printed carbon electrodes (SPCEs) was done by a simple electrodeposition of bismuth that was previously mixed with the sample containing QDs. A magneto-immunosandwich assay was performed using a micromixer. A magnet placed at its outlet in order to capture the magnetic beads used as solid support for the immunoassay. SPCEs were integrated at the end of the channel as detector. Different parameters such as bismuth concentration, flow rate, and incubation times, were optimized. The LOD for HIgG in presence of bismuth was 3.5 ng/mL with a RSD of 13.2%. This LOD was about 3.3-fold lower than the one obtained without bismuth. Furthermore, the sensitivity of the system was increased 100-fold respect to experiments carried out with classical screen-printed electrodes, both in presence of bismuth.