Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 21
Encontrada(s) 1 página(s)

e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

100 GHz multiple colliding pulse generation from cleaved facet-free multi-section semiconductor laser diode

  • Guzmán Martínez, Robinson Cruzoe
  • César Cuello, Jessica
  • Zarzuelo García, Alberto
  • Lo, Mu Chieh
  • Ali, Muhsin
  • Carpintero del Barrio, Guillermo
We present a monolithically integrated mode-locked laser (MLL) with 25 GHz fundamental repetition rate frequency, which has been designed to operate in a fourth-order colliding regime, to generate 100 GHz. This device has been fabricated within a multi-project wafer (MPW) run in an InP-based active-passive generic foundry. The Fabry-Perot laser resonator, of around 1.66 mm length, is defined by two on-chip reflectors, eliminating the need of cleaved facet. Three saturable absorber sections are symmetrically located by spacing them a quarter of this total length, dividing the cavity into four gain segments. We show that this structure can generate an electrical beat note at 25 GHz as well as 100 GHz, with a linewidth of 350 kHz and 150 kHz, respectively, operating in passive operation regime., This work was supported in part by the European Union’s Horizon 2020 (Marie Skłodowska-Curie grant agreement 713694 FiWiN5G) and the Spanish Ministerio de Economia y Competitividad thourgh Programa Estatal de Investigación, Desarrollo e Inovación Orientada a los Retos de la Sociedad thougth grant iTWIT, TEC2016-76997-C3-3-R.
Addi. Archivo Digital para la Docencia y la Investigación
Publication Artículo científico (JournalArticle)

Graphene Nanocomposite Membranes: Fabrication and Water Treatment Applications

  • Memisoglu, Gorkem
  • Murugesan, Raghavan Chinnambedu
  • Zubia Zaballa, Joseba Andoni
  • Rozhin, Aleksey G.
Graphene, a two-dimensional hexagonal honeycomb carbon structure, is widely used in membrane technologies thanks to its unique optical, electrical, mechanical, thermal, chemical and photoelectric properties. The light weight, mechanical strength, anti-bacterial effect, and pollution-adsorption properties of graphene membranes are valuable in water treatment studies. Incorporation of nanoparticles like carbon nanotubes (CNTs) and metal oxide into the graphene filtering nanocomposite membrane structure can provide an improved photocatalysis process in a water treatment system. With the rapid development of graphene nanocomposites and graphene nanocomposite membrane-based acoustically supported filtering systems, including CNTs and visible-light active metal oxide photocatalyst, it is necessary to develop the researches of sustainable and environmentally friendly applications that can lead to new and groundbreaking water treatment systems. In this review, characteristic properties of graphene and graphene nanocomposites are examined, various methods for the synthesis and dispersion processes of graphene, CNTs, metal oxide and polymer nanocomposites and membrane fabrication and characterization techniques are discussed in details with using literature reports and our laboratory experimental results. Recent membrane developments in water treatment applications and graphene-based membranes are reviewed, and the current challenges and future prospects of membrane technology are discussed., This project was supported by the European Union’s Horizon 2020 research and innovation program under the Marie Skłodowska-Curie grant number 713694. The authors (Raghavan Chinnambedu Murugesan and Aleksey G. Rozhin) acknowledge the support of the Marie Skłodowska-Curie Individual Fellowship (MOFUS, # 795356) for this collaboration. These results are funded in part by the Ministerio de Ciencia e Innovación under projects RTC2019-007194-4, PID2021-122505OB-C31 and TED2021-129959B-C21, and in part by Gobierno Vasco/Eusko Jaurlaritza under projects IT1452-22 and ELKARTEK (KK-2021/00082, KK-2021/00092).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Off-axis optical coherence tomography imaging of the crystalline lens to reconstruct the gradient refractive index using optical methods

  • Castro, Alberto de
  • Birkenfeld, Judith S.
  • Heilman, B.M.
  • Ruggeri, M.
  • Arrieta, E.
  • Parel, Jean Marie
  • Manns, Fabrice
  • Marcos, Susana
13 pags., 7 figs., Earlier studies have shown that the gradient index of refraction (GRIN) of the crystalline lens can be reconstructed in vitro using Optical Coherence Tomography (OCT) images. However, the methodology cannot be extended in vivo because it requires accurate measurements of the external geometry of the lens. Specifically, the posterior surface is measured by flipping the lens so that the posterior lens surface faces the OCT beam, a method that cannot be implemented in vivo. When the posterior surface is imaged through the lens in its natural position, it appears distorted by the unknown GRIN. In this study, we demonstrate a method to reconstruct both the GRIN and the posterior surface shape without the need to flip the lens by applying optimization routines using both on-axis and off-axis OCT images of cynomolgous monkey crystalline lenses, obtained by rotating the OCT delivery probe from -45 to +45 degrees in 5 degree steps. We found that the GRIN profile parameters can be reconstructed with precisions up to 0.009, 0.004, 1.7 and 1.1 (nucleus and surface refractive indices, and axial and meridional power law, respectively), the radius of curvature within 0.089 mm and the conic constant within 0.3. While the method was applied on isolated crystalline lenses, it paves the way to in vivo lens GRIN and posterior lens surface reconstruction., European Research Council (ERC) under European Union’s Horizon 2020 research and innovation programme (H2020-MSCA COFUND-2015 FP-713694, MULTIPLY); Spanish government (FIS2014-56643-R, FIS2017-84753-R); European Research Council under the European Union’s Seventh Framework programme (ERC-2011-AdG-2940); National Eye Institute (R01EY021834; F31EY021444); Ruth L. Kirschstein National Research Service Award Individual Pre-doctoral Fellowship (P30EY14801 Center Core Grant); the Florida Lions Eye Bank and Beauty of Sight Foundation; the Henri and Flore Lesieur Foundation.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Morphological changes of human crystalline lens in myopia

  • Muralidharan, Geethika
  • Martínez-Enríquez, Eduardo
  • Birkenfeld, Judith S.
  • Velasco Ocaña, Miriam
  • Pérez Merino, Pablo
  • Marcos, Susana
12 pags., 3 figs., 2 tabs., Ocular biometric parameters, including full shape crystalline lens, were assessed in myopes and emmetropes using 3-D optical coherence tomography. The anterior chamber depth, the radius of the curvature of the anterior cornea, anterior lens, and posterior lens, lens thickness, lens equatorial diameter, surface area, equatorial position, volume, and power, were evaluated as functions of refractive errors and axial lengths while controlling for age effects. The crystalline lens appears to change with myopia consistent with lens thinning, equatorial, and capsular stretching while keeping constant volume. Axial elongation appears counteracted by a crystalline lens power reduction, while corneal power remains unaffected., European Research Council (ERC-2011-AdG- 294099, H-2020-MSCA-COFUND-2015 Ref. 713694, H-2020-MSCA-ITN-2015-ETN-MyFUN No: 675137); Ministerio de Ciencia, Innovación y Universidades (FIS 2017-84753 R MYOPT).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Low-dimensional nano-patterned surface fabricated by direct-write UV-chemically induced geometric inscription technique

  • Allsop, Thomas D.P.
  • Neal, R.
  • Kundrat, V.
  • Wang, C.
  • Mou, C.
  • Culverhouse, P.
  • Ania Castañón, Juan Diego
  • Kalli, K.
  • Webb, D.J.
4 pags., 4 figs., We investigate a nano-patterning process which creates reproducible periodic surface topological features that range in size from ∼100 μm to ∼20 μm. Specifically, we have fabricated multi-layered thin films consisting of germanium/silicon strata on a planar substrate, with each layer having nanometers thickness. The material processing exploits focused 244 nm ultra-violet laser light and an opto-mechanical setup typically applied to the inscription of fiber gratings, and is based upon the well-known material compaction interaction of ultra-violet light with germanium oxides. We show this process can be extended to create arrays of metal nano-antennas by adding a metal overlay to the thin film. This results in arrays with dimensions that span nanometer- to centimeter-length scales. Also, each nano-antenna consists of “nano-blocks.” Experimental data are presented that show the UV irradiance dosage used to create these metal nanostructures on D-shaped optical fibers has a direct relationship to their transmission spectral characteristics as plasmonic devices., Engineering and Physical Sciences Research Council (EPSRC) (EP/J010391, EP/J010413); H2020 Marie Skłodowska-Curie Actions (MSCA) COFUND Action MULTIPLY (713694).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Age-related changes to the three-dimensional full shape of the isolated human crystalline lens

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Mohamed, Ashik
  • Sravani, N. Geetha
  • Ruggeri, Marco
  • Manns, Fabrice
  • Marcos, Susana
11 pags., 4 figs., 4 tabs., PURPOSE. Studying the full shape crystalline lens geometry is important to understand the changes undergone by the crystalline lens leading to presbyopia, cataract, or failure of emmetropization, and to aid in the design and selection of intraocular lenses and new strategies for correction. We used custom-developed three-dimensional (3-D) quantitative optical coherence tomography (OCT) to study age-related changes in the full shape of the isolated human crystalline lens. METHODS. A total of 103 ex vivo human isolated lenses from 87 subjects (age range, 0-56 years) were imaged using a 3-D spectral-domain OCT system. Lens models, constructed after segmentation of the surfaces and distortion correction, were used to automatically quantify central geometric parameters (lens thickness, radii of curvatures, and asphericities of anterior and posterior surfaces) and full shape parameters (lens volume, surface area, diameter, and equatorial plane position). Age-dependencies of these parameters were studied. RESULTS. Most of the measured parameters showed a biphasic behavior, statistically significantly increasing (radii of curvature, lens volume, surface area, diameter) or decreasing (asphericities, lens thickness) very fast in the first two decades of life, followed by a slow but significant increase after age 20 years (for all the parameters except for the posterior surface asphericity and the equatorial plane position, that remained constant). CONCLUSIONS. Three-dimensional quantitative OCT allowed us to study the age-dependency of geometric parameters of the full isolated human crystalline lens. We found that most of the lens geometric parameters showed a biphasic behavior, changing rapidly before age 20 years and with a slower linear growth thereafter., Supported by the Ministerio de Educación y Ciencia, Spain (FIS2017- 84753-R), European Research Council (ERC-2011- AdG-294099), and IMCUSTOMEYE Ref. 779960 (H2020-ICT2017-1) (SM), and European Research Council under Euro pean Union’s Horizon 2020 research and innovation programme H2020-MSCA COFUND-2015 FP-713694, MULTIPLY (AdC), Consejo Superior de Investigaciones Científicas ICoop Program, National Eye Institute (Grants 2R01EY021834, P30EY14801) (Center Grant), the Hyderabad Eye Research Foundation, Florida Lions Eye Bank and the Beauty of Sight Foundation, and an unrestricted grant from Research to Prevent Blindness
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Crystalline lens gradient refractive index distribution in the guinea pig

  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Revuelta, Luis
  • McFadden, Sally A.
  • Marcos, Susana
8 pags., 6 figs., Purpose: The crystalline lens undergoes morphological and functional changes with age and may also play a role in eye emmetropisation. Both the geometry and the gradient index of refraction (GRIN) distribution contribute to the lens optical properties. We studied the lens GRIN in the guinea pig, a common animal model to study myopia. Methods: Lenses were extracted from guinea pigs (Cavia porcellus) at 18 days of age (n = 4, three monolaterally treated with negative lenses and one untreated) and 39 days of age (n = 4, all untreated). Treated eyes were myopic (−2.07 D on average) and untreated eyes hyperopic (+3.3 D), as revealed using streak retinoscopy in the live and cyclopeged animals. A custom 3D spectral domain optical coherence tomography (OCT) system (λ = 840 nm, Δλ = 50 nm) was used to image the enucleated crystalline lens at two orientations. Custom algorithms were used to estimate the lens shape and GRIN was modelled with four variables that were reconstructed using the OCT data and a minimisation algorithm. Ray tracing was used to calculate the optical power and spherical aberration assuming a homogeneous refractive index or the estimated GRIN. Results: Guinea pig lenses exhibited nearly parabolic GRIN profiles. When comparing the two age groups (18- and 39 day-old) there was a significant increase in the central thickness (from 3.61 to 3.74 mm), and in the refractive index of the surface (from 1.362 to 1.366) and the nucleus (from 1.443 to 1.454). The presence of GRIN shifted the spherical aberration (−4.1 µm on average) of the lens towards negative values. Conclusions: The guinea pig lens exhibits a GRIN profile with surface and nucleus refractive indices that increase slightly during the first days of life. GRIN plays a major role in the lens optical properties and should be incorporated into computational guinea pig eye models to study emmetropisation, myopia development and ageing., This work was supported by European Research Council (ERC) Grant Agreement ERC-2011-AdC- 294099; ERC under the European Union’s Horizon 2020 research and innovation programme (H2020-MSCA COFUND-2015 FP-713694, MULTIPLY) and under grant agreement No 779960, IMCUSTOMEYE and No 675137 (MyFUun MSCA ITN); Spanish Government Grant FIS2017-84753-R; Hunter Medical Research Institute G1400967 and the University of Newcastle (FVG 1031537 and SSP).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Detection of nitrous oxide using infrared optical plasmonics coupled with carbon nanotubes

  • Allsop, Thomas D.P.
  • Al Araimi, M.
  • Neal, R.
  • Wang, C.
  • Culverhouse, P.
  • Ania Castañón, Juan Diego
  • Webb, D.J.
  • Davey, Paul
  • Gilbert, J.M.
  • Rozhin, A.
12 pags., 7 figs., 1 tab., Interest in gas sensing using functionalised carbon nanotubes is a major area of research that utilises changes in their electrical properties induced by the reaction with a specific gas. This paper describes specific gas sensing on an optical platform consisting of a 2-dimensional nano-structured plasmonic array of nano-antennae/nanowires, with topological dimensions of mean radius of 130 nm, typical length of 20 μm and a period of 500 nm. The array is created by the spatial compaction of germanium oxides when the material interacts with ultra-violet irradiance, it can support infra-red localised surface plasmons. Carbon nanotubes are deposited upon the surface of the plasmonic platform followed by the application of the polyethyleneimine polymer. The resulting nanomaterials-photonic platform gives rise to the selective response to nitrous oxide gases, which are a major contributor to atmospheric degradation. We achieve the device sensitivity up to 100% atmosphere of nitrous oxide with a detection limit of 109 ppm, a maxiumum response time of nineteen seconds and yielding a full-scale deflection of +5.7 nm. This work demonstrates that the optical properties of specific carbon nanotubes can be used in a wide range of sensing applications offering a new sensing paradigm., This work was nancially supported by joint grants EP/J010413 and EP/J010391 for Aston University and the University of Plymouth along with the University of Hull prosperity partnership: EP/R004900/1 from the UK Engineering and Physical Sciences Research Council and Marie Skłodowska-Curie COFUND Action MULTIPLY (project 713694), Spanish MICINN Grant ECOSYSTEM (RTI2018-097957-B-C33) and Comunidad de Madrid SINFOTON2-CM (S2018/NMT-4326). M. A. acknowledges the support from the Ministry of Higher Education, Sultanate of Oman. A. R. acknowledges the Royal Academy of Engineering/ Leverhulme Trust Senior Research Fellowships (LTSRF1617/13/ 57) and EU Horizon 2020 Research and Innovation Staff Exchange Programme (RISE) under Marie Sklodowska-Curie Action (project 690945 “Carther”). Furthermore, we like to thank Prof V. Yukhymchuk and Mr O. Hreshchuk for providing the Raman measurements undertaken at the Department of Optics and Spectroscopy, National Academy of Sciences of Ukraine, Kiev at the Department of Optics and Spectroscopy, National Academy of Sciences of Ukraine, Kiev.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Multi-meridian corneal imaging of air-puff induced deformation for improved detection of biomechanical abnormalities

  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Martínez-Enríquez, Eduardo
  • Germann, James
  • Muralidharan, Geethika
  • Palací, J.
  • Pascual, Daniel
  • Eliasy, A.
  • Abass, A.
  • Solarski, J.
  • Karnowski, K.
  • Wojtkowski, M.
  • Elsheikh, A.
  • Marcos, Susana
19 pags., 10 figs., 2 tabs., Corneal biomechanics play a fundamental role in the genesis and progression of corneal pathologies, such as keratoconus; in corneal remodeling after corneal surgery; and in affecting the measurement accuracy of glaucoma biomarkers, such as the intraocular pressure (IOP). Air-puff induced corneal deformation imaging reveals information highlighting normal and pathological corneal response to a non-contact mechanical excitation. However, current commercial systems are limited to monitoring corneal deformation only on one corneal meridian. Here, we present a novel custom-developed swept-source optical coherence tomography (SSOCT) system, coupled with a collinear air-puff excitation, capable of acquiring dynamic corneal deformation on multiple meridians. Backed by numerical simulations of corneal deformations, we propose two different scan patterns, aided by low coil impedance galvanometric scan mirrors that permit an appropriate compromise between temporal and spatial sampling of the corneal deformation profiles. We customized the air-puff module to provide an unobstructed SSOCT field of view and different peak pressures, air-puff durations, and distances to the eye. We acquired multi-meridian corneal deformation profiles (a) in healthy human eyes in vivo, (b) in porcine eyes ex vivo under varying controlled IOP, and (c) in a keratoconus-mimicking porcine eye ex vivo. We detected deformation asymmetries, as predicted by numerical simulations, otherwise missed on a single meridian that will substantially aid in corneal biomechanics diagnostics and pathology screening., Horizon 2020 Framework Programme (666295, 713694, 779960); Ministerio de Economía, Industria y Competitividad, Gobierno de España (FJC2018-038736-I); Fundacja na rzecz Nauki Polskiej (MAB/2019/12).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Detecting deformation asymmetries on multiple meridians in an ex vivo keratoconic eye model

  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Martínez-Enríquez, Eduardo
  • Germann, James
  • Palací, J.
  • Pascual, Daniel
  • Muralidharan, Geethika
  • Eliasy, A.
  • Abass, A.
  • Solarski, J.
  • Karnowski, Karol
  • Wojtkowski, Maciej
  • Elsheikh, A.
  • Marcos, Susana
1 pag. -- This is a 2020 ARVO Annual Meeting abstract., Support European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694; European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960; European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137; Spanish government grant FIS2017-84753-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Effect of fixational eye movements in corneal topography measurement with OCT

  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Muralidharan, Geethika
  • Curatolo, Andrea
  • Marcos, Susana
1 pag. -- This is a 2020 ARVO Annual Meeting abstract., Support COFUND Multiply: European Research Council (ERC) under European Union’s Horizon 2020 research and innovation programme H2020-MSCA-COFUND-2015-FP-713694; Spanish government grant FIS2017-84753-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

3D OCT-based geometrical changes of human crystalline lenses during simulated accommodation in a lens stretcher

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Mohamed, Ashik
  • Maceo Heilman, B.
  • Williams, S.
  • Nandyala, S.
  • Ruggeri, Marco
  • Parel, J. M. A.
  • Augusteyn, Robert
  • Ho, Arthur
  • Manns, Fabrice
  • Marcos, Susana
This is a 2020 ARVO Annual Meeting abstract., Support European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137, European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960​, European Project SILKEYE H2020-ERC-2018-ADG Ref. 833106, European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694, Spanish government grant FIS2017-84753-R, NEI Grants: R01EY021834, F31EY021444 (Maceo), P30EY14801 (Center Grant); the Florida Lions Eye Bank; Research to Prevent Blindness; Drs. KR Olsen and ME Hildebrandt, Drs. Raksha Urs and Aaron Furtado, the Henri and Flore Lesieur Foundation (JMP); Hyderabad Eye Research Foundation., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Isolated human crystalline lens three-dimensional shape: A comparison between Indian and European populations

  • Mohamed, Ashik
  • Nandyala, S.
  • Martínez-Enríquez, Eduardo
  • Maceo Heilman, B.
  • Augusteyn, Robert
  • Castro, Alberto de
  • Ruggeri, Marco
  • Parel, J. M. A.
  • Marcos, Susana
  • Manns, Fabrice
6 pags., 2 figs., 2 tabs., There have been many studies on lens properties in specific populations (e.g. in China, Europe, Singapore, etc.) some of which suggest there may be differences between populations. Differences could be caused by ethnic or environmental influences or experimental procedures. The purpose of this study is to evaluate if any differences exist between Indian and European populations in the central geometric and full shape properties of human lenses. Two custom-developed spectral domain optical coherence tomography systems were used to acquire the crystalline lens geometry: one in India (69 lenses from 59 donors) and the other in Spain (24 lenses from 19 donors). The steps for obtaining accurate 3-D models from optical coherence tomography raw images comprised of image segmentation, fan and optical distortion correction, tilt removal and registration. The outcome variables were lens equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, central radius of curvature of the anterior and posterior lens surfaces, lens volume and lens surface area. A mixed effects model by maximum likelihood estimation was used to evaluate the effect of age, population and their interaction (age*population) on lens parameters. After adjusting for age, there were no population differences observed in anterior and posterior radii of curvature, equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, volume and surface area (all p ≥ 0.08). There was also no effect of the interaction term on anterior and posterior radii of curvature, equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, volume and surface area (all p ≥ 0.06). All central geometric and full shape parameters appeared to be comparable between the European and Indian populations. This is the first study to compare geometric and full shape lens parameters between different populations in vitro., This work was supported by the National Institutes of Health/National Eye Institute [Grants 2R01EY021834 and P30EY14801 (Center Grant)]; the Hyderabad Eye Research Foundation; Ministerio de Educacion y Ciencia, Spain (FIS2017- 84753-R), European Research Council (ERC-2018-AdG-833106) and IMCUSTOMEYE Ref. 779960 (H2020- ICT- 2017-1) to S. Marcos, and European Research Council (ERC) under European Union’s Horizon 2020 research and innovation programme H2020-MSCA COFUND-2015 FP-713694, MULTIPLY(AdC), CSIC ICoop Program, Florida Lions Eye Bank and the Beauty of Sight Foundation, an unrestricted grant from Research to Prevent Blindness to the Department of Ophthalmology, University of Miami and the Henri and Flore Lesieur Foundation (J-M. Parel).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Detecting deformation asymmetries on multiple meridians in an ex vivo keratoconic eye model

  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Martínez-Enríquez, Eduardo
  • Germann, James
  • Palací, J.
  • Pascual, Daniel
  • Muralidharan, Geethika
  • Eliasy, A.
  • Abass, A.
  • Solarski, J.
  • Karnowski, Karol
  • Wojtkowski, Maciej
  • Elsheikh, A.
  • Marcos, Susana
ARVO Annual Meeting Abstract, Support European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694; European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960; European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137; Spanish government grant FIS2017-84753-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Crystalline lens Gradient Index Profile in the guinea pig myopia model

  • Marcos, Susana
  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Revuelta, Luis
  • McFadden, Sally A.
ARVO Annual Meeting Abstract (2019), Support European Research Council ERC-2011-AdG 294099; Spanish Government FIS2014-56643-R, FIS2017-84753-R; H-2020-MSCA-COFUND-2015 713694, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Intra-Ocular Lens Power Calculation using 3D OCT-based Personalized Computer Eye Models

  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Velasco Ocaña, Miriam
  • Durán, Sonia
  • Jiménez-Alfaro, Ignacio
  • Marcos, Susana
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019, Support European Research Council (ERC) under European Union’s Horizon 2020 research and innovation programme H2020-MSCA-COFUND-2015-FP-713694, Spanish government grant FIS2014-56643-R, European Research Council under the European Union’s Seventh Framework programme ERC-2011-AdG-294099, Patent P201130685, Patent US2016 62/329,392​., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Assessment of asymmetries in biomechanical properties from corneal deformation imaging

  • Birkenfeld, Judith S.
  • Germann, James
  • Castro, Alberto de
  • Hoz, A. de la
  • Curatolo, Andrea
  • Marcos, Susana
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019, Support European Project Multiply H-2020-MSCA-COFUND-2015 Ref. 713694, Spanish Government Grant FIS2017-84753-R, European Project Presbyopia ERC-2011-AdG Ref. 294099, European Project Imcustomeye H2020-ICT-2017 Ref. 779960, BES-2015-072197, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Generation of a conjoint surface plasmon by an infrared nano-antenna array

  • Allsop, Thomas D.P.
  • Mou, Chengbo
  • Neal, Ronald
  • Kundrat, V.
  • Wang, Changle
  • Kalli, K.
  • Webb, David
  • Liu, Xiaoping
  • Davey, Paul
  • Culverhouse, P.
  • Ania Castañón, Juan Diego
13 pags., 7 figs., 1 tab., Localized surface plasmons (LSP) excited by optical fields have many potential applications resulting from their ability in detecting ultra-small, ambient refractive index change. Current methods using surface nano-patterning by means of lithography have given rise to LSP of limited propagation and interaction lengths, meaning that practical applications remain challenging. This article describes a new all-optical method of generating LSP by means of a carefully fabricated low-dimensional nano-structured material using a direct-write photochemical lithography. It is shown that the resulting array of localized SPs combine or “Conjoin” to have an unprecedented large interaction length, via coupled evanescent fields, giving rise to superior spectral sensitivities; several orders of magnitude better than those quoted elsewhere and reaching 6 × 103 nm RIU−1 in the aqueous regime and 104 nm RIU−1 in the gaseous regime. Numerical modeling is performed that shows this design of plasmonic platform is capable of producing sensitivities of 105–106 nm RIU−1. It is believed the results achieved in this investigation show that a unique conjoint SP operational mode will significantly impact areas of interest, such as single molecular dynamics, drug delivery systems, etc., This work was financially supported by joint grants EP/J010413and EP/J010391 for Aston University and the University of Plymouthalong with the University of Hull prosperity partnership: EP/R004900/1from the UK Engineering and Physical Sciences ResearchCouncil. C.M. acknowledges the support from National Natural Science Foundation of China (No. 61605107), as well as the European Commission Marie Skłodowska-Curie COFUND Action MULTIPLY(project 713694) and Spanish MICINN grant ECOSYSTEM(RTI2018-097957-B-C33), Comunidad de Madrid grant SINFOTON2-CM (S2018/NMT-4326), young Eastern Scholar Program from Shanghai Institutions of Higher Learnings (QD2015027), and National Young 1000 Talent Plan Program of China.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Nonlinear Dynamics of a Single-Mode Semiconductor Laser with Long Delayed Optical Feedback: A Modern Experimental Characterization Approach

  • Porte, Xavier
  • Brunner, Daniel
  • Fischer, Ingo
  • Soriano, Miguel C.
Semiconductor lasers can exhibit complex dynamical behavior in the presence of external perturbations. Delayed optical feedback, re-injecting part of the emitted light back into the laser cavity, in particular, can destabilize the laser’s emission. We focus on the emission properties of a semiconductor laser subject to such optical feedback, where the delay of the light re-injection is large compared to the relaxation oscillations period. We present an overview of the main dynamical features that emerge in semiconductor lasers subject to delayed optical feedback, emphasizing how to experimentally characterize these features using intensity and high-resolution optical spectra measurements. The characterization of the system requires the experimentalist to be able to simultaneously measure multiple time scales that can be up to six orders of magnitude apart, from the picosecond to the microsecond range. We highlight some experimental observations that are particularly interesting from the fundamental point of view and, moreover, provide opportunities for future photonic applications., We acknowledge the Spanish State Research Agency, through the Severo Ochoa and María de Maeztu Program for Centers and Units of Excellence in R&D, grant MDM-2017-0711 funded by MCIN/AEI/10.13039/501100011033. X.P. acknowledges funding from the European Union’s Horizon 2020 (713694) and the Volkswagen Foundation (NeuroQNet II).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Estimation of scleral mechanical properties from air-puff optical coherence tomography

  • Bronte-Ciriza, David
  • Birkenfeld, Judith S.
  • Hoz, A. de la
  • Curatolo, Andrea
  • Germann, James
  • Villegas, Lupe
  • Varea, Alejandra
  • Martínez-Enríquez, Eduardo
  • Marcos, Susana
19 pages, 7 figures, 2 tables, We introduce a method to estimate the biomechanical properties of the porcine sclera in intact eye globes ex vivo, using optical coherence tomography that is coupled with an air-puff excitation source, and inverse optimization techniques based on finite element modeling. Air-puff induced tissue deformation was determined at seven different locations on the ocular globe, and the maximum apex deformation, the deformation velocity, and the arc-length during deformation were quantified. In the sclera, the experimental maximum deformation amplitude and the corresponding arc length were dependent on the location of air-puff excitation. The normalized temporal deformation profile of the sclera was distinct from that in the cornea, but similar in all tested scleral locations, suggesting that this profile is independent of variations in scleral thickness. Inverse optimization techniques showed that the estimated scleral elastic modulus ranged from 1.84 ± 0.30 MPa (equatorial inferior) to 6.04 ± 2.11 MPa (equatorial temporal). The use of scleral air-puff imaging holds promise for non-invasively investigating the structural changes in the sclera associated with myopia and glaucoma, and for monitoring potential modulation of scleral stiffness in disease or treatment., European Research Council (2018-ADG-SILKEYE-833106); Horizon 2020 Framework Programme European Project Multiply (H-2020-MSCACOFUND-2015 Ref. 713694); Spanish Government (FIS2017-84753-R); Horizon 2020 Framework Programme European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); Spanish Government (CSIC JAE Intro Fellowship); L’Oréal-UNESCO “For Women in Science” Spain; Spanish Government Juan de la Cierva-Incorporation Fellowship (IJC2018-037508-I); Fundacja na rzecz Nauki Polskiej (MAB/2019/12); National Agency for Academic Exchange, Polish Government (NAWA ULAM/2020/1/00176), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Eigenlenses: A new model for full crystalline lens shape representation and its applications

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Marcos, Susana
17 pages, 8 figures, 1 table, The crystalline lens is an important optical element in the eye, responsible for focusing, and which experiences significant changes throughout life. The shape of the lens is usually studied only in the optical area (central 4 to 6 mm). However, for a great number of applications, a description of the full shape of the crystalline lens is required. We propose a new method for the representation of the full shape of the crystalline lens, constructed from 3-dimensional optical coherence tomography images of 133 isolated crystalline lenses (0-71 y/o), which we have called eigenlenses. The method is shown to be compact and accurate to describe not only the full shape of the crystalline lens, but also the optical zone in comparison with other methods. We also demonstrate its application to the extrapolation of the full shape of the crystalline lens from in-vivo optical images of the anterior segment of the eye, where only the central part of the lens visible through the pupil is available, and in the generation (synthesis) of realistic full lenses of a given age. The method has critical applications, among others, in improving and evaluating myopia and presbyopia treatments., H2020 European Research Council (H2020-MSCA COFUND-2015 FP-713694, MULTIPLY (AdC));Ministerio de Economía y Competitividad (FIS2017-84753-R); Horizon2020 Framework Programme (IMCUSTOMEYE Ref. 779960 (H2020-ICT- 2017-1)); European Research Council (ERC-2011-AdG-294099); National Institutes of Health (R01EY021834).