Skip to main content

NUEVAS TECNOLOGIAS OPTICAS PARA ENTENDER Y TRATAR LA MIOPIA

FIS2017-84753-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 59
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Experimental validations of a tunable-lens-based visual demonstrator of multifocal corrections

  • Akondi, Vyas
  • Sawides, L.
  • Marrakchi, Y.
  • Gambra, Enrique
  • Marcos, Susana
  • Dorronsoro, Carlos
16 pags., 8 figs. 2 tabs., The Simultaneous Vision simulator (SimVis) is a visual demonstrator of multifocal lens designs for prospective intraocular lens replacement surgery patients and contact lens wearers. This programmable device employs a fast tunable lens and works on the principle of temporal multiplexing. The SimVis input signal is tailored to mimic the optical quality of the multifocal lens using the theoretical SimVis temporal profile, which is evaluated from the through-focus Visual Strehl ratio metric of the multifocal lens. In this paper, for the first time, focimeter-verified on-bench validations of multifocal simulations using SimVis are presented. Two steps are identified as being critical to accurate SimVis simulations. Firstly, a new iterative approach is presented that improves the accuracy of the theoretical SimVis temporal profile for three different multifocal intraocular lens designs – diffractive trifocal, refractive segmented bifocal, and refractive extended depth of focus, while retaining a low sampling. Secondly, a fast focimeter is used to measure the step response of the tunable lens, and the input signal is corrected to include the effects of the transient behavior of the tunable lens. It was found that the root-mean-square of the difference between the estimated through-focus Visual Strehl ratio of the multifocal lens and SimVis is not greater than 0.02 for all the tested multifocal designs., Consejería de Educación, Juventud y Deporte of Comunidad de Madrid and the People Programme (Marie Curie Actions) of the European Union’s Seventh Framework Programme (FP7/2007-2013) (n 291820 to VA); EU H2020 SME Innovation Associate (GA-739882); Spanish Government Torres-Quevedo Program (PTQ-15-07432); EIT Health (2017 HS PoC Spain 05); Ministerio de Economía y Competitividad (DTS16-00127); ERC (ERC-2011-AdC 294099); Spanish Government (FIS2014-56643-R, FIS2017-84753-R)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Visual simulators replicate vision with multifocal lenses

  • Viñas, María
  • Benedi, Clara
  • Aissati, Sara
  • Pascual, Daniel
  • Akondi, Vyas
  • Dorronsoro, Carlos
  • Marcos, Susana
11 pags., 7 figs. -- Open Access funded by Creative Commons Atribution Licence 4.0, Adaptive optics (AO) visual simulators based on deformable mirrors, spatial light modulators or optotunable lenses are increasingly used to simulate vision through different multifocal lens designs. However, the correspondence of this simulation with that obtained through real intraocular lenses (IOLs) tested on the same eyes has not been, to our knowledge, demonstrated. We compare through-focus (TF) optical and visual quality produced by real multifocal IOLs (M-IOLs) -bifocal refractive and trifocal diffractive- projected on the subiect’s eye with those same designs simulated with a spatial light modulator (SLM) or an optotunable lens working in temporal multiplexing mode (SimVis technology). Measurements were performed on 7 cyclopleged subjects using a custom-made multichannel 3-active-optical-elements polychromatic AO Visual Simulator in monochromatic light. The same system was used to demonstrate performance of the real IOLs, SLM and SimVis technology simulations on bench using double-pass imaging on an artificial eye. Results show a general good correspondence between the TF performance with the real and simulated M-IOLs, both optically (on bench) and visually (measured visual acuity in patients). We demonstrate that visual simulations in an AO environment capture to a large extent the individual optical and visual performance obtained with real M-IOLs, both in absolute values and in the shape of through-focus curves., Tis research has received funding from the European Research Council under the European Union’s Seventh Framework Program (FP/2007–2013)/ERC Grant Agreement. [ERC-2011-AdC 294099]; the H2020 COFUND Marie Curie 291820 program; ERCPoC SimVis project. Tis study was also supported by Spanish Government grant FIS2014-56643-R to S.M., FIS2017-84753-R to S.M. and C.D., and DTS16-00127 to C.D., and Spanish Government FPU Predoctoral Fellowship (FPU16/01944) to S.A. Authors thank Laura Barrios from the Scientifc Calculus Center of the Spanish National Research Council (CSIC) for help with the statistical analysis.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Vision with different presbyopia corrections simulated with a portable binocular visual simulator

  • Radhakrishnan, Aiswaryah
  • Pascual, Daniel
  • Marcos, Susana
  • Dorronsoro, Carlos
13 pags., 5 figs.-- Open Access funded by Creative Commons Atribution Licence 4.0, Presbyopes can choose today among different corrections to provide them with functional vision at far and near, and the outcomes and patient satisfaction depend on the selection. In this study, we present a binocular and portable vision simulator, based on temporal multiplexing of two synchronized tunable lenses allowing see-through and programmable visual simulations of presbyopic corrections. Seventeen binocular corrections were tested: 3 Monofocal (Far, Intermediate, Near), 4 Simultaneous Vision (bifocal, trifocal), 2 Monovision (far and near in either eye) and 8 Modified Monovision corrections (Simultaneous vision in one eye, Monofocal in the other eye). Perceived visual quality was assessed through the simulated corrections in 8 cyclopleged subjects who viewed a composite realistic visual scene with high contrast letters and a landscape at far (4 m) and a high contrast text at intermediate (66 cm) and near (33 cm) distances. Perceptual scores were obtained on a scale of 0 to 5 (low to high perceived quality). Perceptual preference was assessed by judging 36 random image pairs (6 repetitions) viewed through 9 binocular presbyopic corrections using two-interval forced choice procedures. The average score, across far and near distances, was the highest for Monovision (4.4±0.3), followed by Modified Monovision (3.4±0.1), Simultaneous Vision (3.0±0.1) and Monofocal corrections (2.9±0.2). However, the mean difference between far and near was lower for Simultaneous Vision and Monovision (0.4±0.1 PS) than Modified Monovision (1.8±0.7) or monofocal corrections (3.3±1.5). A strong significant correlation was found between the perceptual scores and the percentages of energy in focus, for each correction and distance (R = 0.64, p<0.0001). Multivariate ANOVA revealed significant influence of observation distances (p<10–9) and patients (p = 0.01) on Perceptual Score. In conclusion, we have developed a binocular portable vision simulator that can simulate rapidly and non-invasively different combinations of presbyopic corrections. This tool has applications in systematic clinical evaluation of presbyopia corrections., This work was supported by: European Research Council under the European Union’s Seventh Framework Programme FP7/2007-2013, ERC Grant Agreement nº ERC-AdG-294099, Spanish Government grant FIS2014-56643-R to SM; ISCIII DTS16/00127 to CD; Spanish Government grant FIS2017-84753-R to CD and SM; and by 7th Framework Programme of the European Community through the Marie Curie
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Tunable lenses: Dynamic characterization and fine-tuned control for high-speed applications

  • Dorronsoro, Carlos
  • Barcala, Xoana
  • Gambra, Enrique
  • Akondi, Vyas
  • Sawides, L.
  • Marrakchi, Y.
  • Rodríguez-López, Víctor
  • Benedi, Clara
  • Viñas, María
  • Lage, Eduardo
  • Marcos, Susana
16 pags., 9 figs., 1 tab., Tunable lenses are becoming ubiquitous, in applications including microscopy, optical coherence tomography, computer vision, quality control, and presbyopic corrections. Many applications require an accurate control of the optical power of the lens in response to a time-dependent input waveform. We present a fast focimeter (3.8 KHz) to characterize the dynamic response of tunable lenses, which was demonstrated on different lens models. We found that the temporal response is repetitive and linear, which allowed the development of a robust compensation strategy based on the optimization of the input wave, using a linear time-invariant model. To our knowledge, this work presents the first procedure for a direct characterization of the transient response of tunable lenses and for compensation of their temporal distortions, and broadens the potential of tunable lenses also in high-speed applications., VA and EL acknowledge financial support from Comunidad de Madrid and Marie Curie Action of the European Union FP7/2007-2013 COFUND 291820; XB from Comunidad de Madrid Doctorado Industrial IND2017/BMD-7670; EL from Spanish Government Ramon y Cajal Program RyC-2016-21125; EG from Spanish Government Torres-Quevedo Program PTQ-15-07432; LS from EU H2020 SME Innovation Associate GA-739882; EG from EIT Health; SM from ERC Grant Agreement ERC-2011-AdC 294099 and Spanish Government Grants FIS2014-56643-R; SM and CD from Spanish Government Grant FIS2017-84753-R; and CD from DTS16-00127.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Pre-operative simulation of post-operative multifocal vision

  • Viñas, María
  • Aissati, Sara
  • Romero, Mercedes
  • Benedi, Clara
  • Garzón, N.
  • Poyales, F.
  • Dorronsoro, Carlos
  • Marcos, Susana
17 pags., 6 figs., 1 tab., While multifocal intraocular lenses (MIOLs) are increasingly implanted to correct for presbyopia, how one sees with a multifocal correction is hard to explain and imagine. The current study evaluates the quality of various visual simulating technologies by comparing vision with simulated MIOLs pre-operatively and the implanted MIOLs post-operatively in the same patients. Two simulation platforms were used: (1) a custom-developed adaptiveoptics (AO) system, with two visual simulator devices: a spatial light modulator (SLM) and an optotunable lens operating under temporal multiplexing (SimVis); and (2) a wearable, binocular, large field of view SimVis2Eyes clinical simulator (SimVis Gekko, 2Eyes Vision, Madrid, Spain). All devices were programmed to simulate a trifocal diffractive MIOL (POD F, FineVision, PhysIOL). Eight patients were measured pre-operatively simulating the trifocal lens and post-operatively with implantation of the same MIOL. Through-focus decimal visual acuity (TF VA) was measured (1) monocularly in monochromatic light using a four-alternative-forced-choice procedure in the AO system; and (2) binocularly using a clinical optotype in white light. Visual simulations pre-operatively predict well the TF VA performance found post-operatively in patients implanted with the real IOL. The average RMS difference between TF curves with the different visual simulators was 0.05 ± 0.01. The average RMS difference between the TF VA curves with the SimVis pre-operatively and the real MIOL post-operatively was 0.06 ± 0.01 in both platforms, and it was higher in cataract eyes (0.08 ± 0.01, on average across simulators) than in eyes with clear lens. In either group the shape of the TF curves is similar across simulators and pre- and post-operatively. TF curves cross-correlated significantly between simulators (lag k = 0, rho = 0.889), as well as with results with the real MIOL implanted (lag k = 0, rho = 0.853). Visual simulations are useful programmable tools to predict visual performance with MIOLs, both in an AO environment and in a clinical simulator. Pre-operative visual simulations and post-operative data are in good agreement., European Research Council (ERC-2011-AdC 294099); H2020 Marie Skłodowska-Curie Actions (H2020 COFUND Marie Curie European Research Council (ERC-2011-AdC 294099); H2020 Marie Skłodowska-Curie Actions (H2020 COFUND Marie Curie 291820 program); Spanish Goverment (FIS2014- 56643R, FIS2017-84753R, FPU16/01944, ISCIII DTS16/00127); Private company PhysIOL (Collaborative agreement). program); Spanish Goverment (FIS2014- 56643R, FIS2017-84753R, FPU16/01944, ISCIII DTS16/00127); Private company PhysIOL (Collaborative agreement).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Off-axis optical coherence tomography imaging of the crystalline lens to reconstruct the gradient refractive index using optical methods

  • Castro, Alberto de
  • Birkenfeld, Judith S.
  • Heilman, B.M.
  • Ruggeri, M.
  • Arrieta, E.
  • Parel, Jean Marie
  • Manns, Fabrice
  • Marcos, Susana
13 pags., 7 figs., Earlier studies have shown that the gradient index of refraction (GRIN) of the crystalline lens can be reconstructed in vitro using Optical Coherence Tomography (OCT) images. However, the methodology cannot be extended in vivo because it requires accurate measurements of the external geometry of the lens. Specifically, the posterior surface is measured by flipping the lens so that the posterior lens surface faces the OCT beam, a method that cannot be implemented in vivo. When the posterior surface is imaged through the lens in its natural position, it appears distorted by the unknown GRIN. In this study, we demonstrate a method to reconstruct both the GRIN and the posterior surface shape without the need to flip the lens by applying optimization routines using both on-axis and off-axis OCT images of cynomolgous monkey crystalline lenses, obtained by rotating the OCT delivery probe from -45 to +45 degrees in 5 degree steps. We found that the GRIN profile parameters can be reconstructed with precisions up to 0.009, 0.004, 1.7 and 1.1 (nucleus and surface refractive indices, and axial and meridional power law, respectively), the radius of curvature within 0.089 mm and the conic constant within 0.3. While the method was applied on isolated crystalline lenses, it paves the way to in vivo lens GRIN and posterior lens surface reconstruction., European Research Council (ERC) under European Union’s Horizon 2020 research and innovation programme (H2020-MSCA COFUND-2015 FP-713694, MULTIPLY); Spanish government (FIS2014-56643-R, FIS2017-84753-R); European Research Council under the European Union’s Seventh Framework programme (ERC-2011-AdG-2940); National Eye Institute (R01EY021834; F31EY021444); Ruth L. Kirschstein National Research Service Award Individual Pre-doctoral Fellowship (P30EY14801 Center Core Grant); the Florida Lions Eye Bank and Beauty of Sight Foundation; the Henri and Flore Lesieur Foundation.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Morphological changes of human crystalline lens in myopia

  • Muralidharan, Geethika
  • Martínez-Enríquez, Eduardo
  • Birkenfeld, Judith S.
  • Velasco Ocaña, Miriam
  • Pérez Merino, Pablo
  • Marcos, Susana
12 pags., 3 figs., 2 tabs., Ocular biometric parameters, including full shape crystalline lens, were assessed in myopes and emmetropes using 3-D optical coherence tomography. The anterior chamber depth, the radius of the curvature of the anterior cornea, anterior lens, and posterior lens, lens thickness, lens equatorial diameter, surface area, equatorial position, volume, and power, were evaluated as functions of refractive errors and axial lengths while controlling for age effects. The crystalline lens appears to change with myopia consistent with lens thinning, equatorial, and capsular stretching while keeping constant volume. Axial elongation appears counteracted by a crystalline lens power reduction, while corneal power remains unaffected., European Research Council (ERC-2011-AdG- 294099, H-2020-MSCA-COFUND-2015 Ref. 713694, H-2020-MSCA-ITN-2015-ETN-MyFUN No: 675137); Ministerio de Ciencia, Innovación y Universidades (FIS 2017-84753 R MYOPT).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Monovision and the Misperception of Motion

  • Burge, Johannes
  • Rodríguez-López, Víctor
  • Dorronsoro, Carlos
11 pags., 4 figs., 1 tab. -- Open Access funded by Creative Commons Atribution Licence 4.0, Monovision is a common prescription lens correction for presbyopia [1]. Each eye is corrected for a different distance, causing one image to be blurrier than the other. Millions of people have monovision corrections, but little is known about how interocular blur differences affect motion perception. Here, we report that blur differences cause a previously unknown motion illusion that makes people dramatically misperceive the distance and three-dimensional direction of moving objects. The effect occurs because the blurry and sharp images are processed at different speeds. For moving objects, the mismatch in processing speed causes a neural disparity, which results in the misperceptions. A variant of a 100-year-old stereo-motion phenomenon called the Pulfrich effect [2], the illusion poses an apparent paradox: blur reduces contrast, and contrast reductions are known to cause neural processing delays [3–6], but our results indicate that blurry images are processed milliseconds more quickly. We resolve the paradox with known properties of the early visual system, show that the misperceptions can be severe enough to impact public safety, and demonstrate that the misperceptions can be eliminated with novel combinations of non-invasive ophthalmic interventions. The fact that substantial perceptual errors are caused by millisecond differences in processing speed highlights the exquisite temporal calibration required for accurate perceptual estimation. The motion illusion—the reverse Pulfrich effect—and the paradigm we use to measure it should help reveal how optical and image properties impact temporal processing, an important but understudied issue in vision and visual neuroscience. Burge et al. show that the interocular blur differences caused by a common prescription lens correction can cause dramatic misperceptions of motion. The illusions may impact public safety. The authors explain the illusion and demonstrate that appropriate combination of non-invasive ophthalmic interventions can eliminate the illusion., This work was supported by NIH grant R01-EY028571 from the National Eye Institute and the Office of Social and Behavioral Science to J.B., startup funds from the University of Pennsylvania to J.B., Spanish Ministry of Education grant FPU17/02760 to V.R.L., and Spanish Ministry of Science, Innovation, and Universities grants ISCIII DTS2016/00127 and FIS2017-84753-R to C.D.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Age-related changes to the three-dimensional full shape of the isolated human crystalline lens

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Mohamed, Ashik
  • Sravani, N. Geetha
  • Ruggeri, Marco
  • Manns, Fabrice
  • Marcos, Susana
11 pags., 4 figs., 4 tabs., PURPOSE. Studying the full shape crystalline lens geometry is important to understand the changes undergone by the crystalline lens leading to presbyopia, cataract, or failure of emmetropization, and to aid in the design and selection of intraocular lenses and new strategies for correction. We used custom-developed three-dimensional (3-D) quantitative optical coherence tomography (OCT) to study age-related changes in the full shape of the isolated human crystalline lens. METHODS. A total of 103 ex vivo human isolated lenses from 87 subjects (age range, 0-56 years) were imaged using a 3-D spectral-domain OCT system. Lens models, constructed after segmentation of the surfaces and distortion correction, were used to automatically quantify central geometric parameters (lens thickness, radii of curvatures, and asphericities of anterior and posterior surfaces) and full shape parameters (lens volume, surface area, diameter, and equatorial plane position). Age-dependencies of these parameters were studied. RESULTS. Most of the measured parameters showed a biphasic behavior, statistically significantly increasing (radii of curvature, lens volume, surface area, diameter) or decreasing (asphericities, lens thickness) very fast in the first two decades of life, followed by a slow but significant increase after age 20 years (for all the parameters except for the posterior surface asphericity and the equatorial plane position, that remained constant). CONCLUSIONS. Three-dimensional quantitative OCT allowed us to study the age-dependency of geometric parameters of the full isolated human crystalline lens. We found that most of the lens geometric parameters showed a biphasic behavior, changing rapidly before age 20 years and with a slower linear growth thereafter., Supported by the Ministerio de Educación y Ciencia, Spain (FIS2017- 84753-R), European Research Council (ERC-2011- AdG-294099), and IMCUSTOMEYE Ref. 779960 (H2020-ICT2017-1) (SM), and European Research Council under Euro pean Union’s Horizon 2020 research and innovation programme H2020-MSCA COFUND-2015 FP-713694, MULTIPLY (AdC), Consejo Superior de Investigaciones Científicas ICoop Program, National Eye Institute (Grants 2R01EY021834, P30EY14801) (Center Grant), the Hyderabad Eye Research Foundation, Florida Lions Eye Bank and the Beauty of Sight Foundation, and an unrestricted grant from Research to Prevent Blindness
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Corneal collagen ordering after in vivo Rose Bengal and riboflavin cross-linking

  • Germann, James
  • Martínez-Enríquez, Eduardo
  • Martínez-García, Carmen
  • Kochevar, Irene E.
  • Marcos, Susana
8 pags., 6 figs., PURPOSE. Photoactivated cornea collagen cross-linking (CXL) increases corneal stiffness by initiating formation of covalent bonds between stromal proteins. Because CXL depends on diffusion to distribute the photoinitiator, a gradient of CXL efficiency with depth is expected that may affect the degree of stromal collagen organization. We used second harmonic generation (SHG) microscopy to investigate the differences in stromal collagen organization in rabbit eyes after corneal CXL in vivo as a function of depth and time after surgery. METHODS. Rabbit corneas were treated in vivo with either riboflavin/UV radiation (UVX) or Rose Bengal/green light (RGX) and evaluated 1 and 2 months after CXL. Collagen fibers were imaged with a custom-built SHG scanning microscope through the central cornea (350 μm depth, 225 × 225 μm en face images). The order coefficient (OC), a metric for collagen organization, and total SHG signal were computed for each depth and compared between treatments. RESULTS. OC values of CXL-treated corneas were larger than untreated corneas by 27% and 20% after 1 month and 38% and 33% after 2 months for the RGX and UVX, respectively. RGX OC values were larger than UVX OC values by 3% and 5% at 1 and 2 months. The SHG signal was higher in CXL corneas than untreated corneas, both at 1 and 2 months after surgery, by 18% and 26% and 1% and 10% for RGX and UVX, respectively. CONCLUSIONS. Increased OC corresponded with increased collagen fiber organization in CXL corneas. Changes in collagen organization parallel reported temporal changes in cornea stiffness after CXL and also, surprisingly, are detected deeper in the stroma than the regions stiffened by collagen cross-links., Supported by the European Research Council Advanced Grant ERC-2011-AdG Ref. 294099, Spanish Government Grants FIS2014-56643 and FIS2017-84753-R, H2020 Research and Innovation Action H2020-ICT-2017 Ref. 779960.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Crystalline lens gradient refractive index distribution in the guinea pig

  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Revuelta, Luis
  • McFadden, Sally A.
  • Marcos, Susana
8 pags., 6 figs., Purpose: The crystalline lens undergoes morphological and functional changes with age and may also play a role in eye emmetropisation. Both the geometry and the gradient index of refraction (GRIN) distribution contribute to the lens optical properties. We studied the lens GRIN in the guinea pig, a common animal model to study myopia. Methods: Lenses were extracted from guinea pigs (Cavia porcellus) at 18 days of age (n = 4, three monolaterally treated with negative lenses and one untreated) and 39 days of age (n = 4, all untreated). Treated eyes were myopic (−2.07 D on average) and untreated eyes hyperopic (+3.3 D), as revealed using streak retinoscopy in the live and cyclopeged animals. A custom 3D spectral domain optical coherence tomography (OCT) system (λ = 840 nm, Δλ = 50 nm) was used to image the enucleated crystalline lens at two orientations. Custom algorithms were used to estimate the lens shape and GRIN was modelled with four variables that were reconstructed using the OCT data and a minimisation algorithm. Ray tracing was used to calculate the optical power and spherical aberration assuming a homogeneous refractive index or the estimated GRIN. Results: Guinea pig lenses exhibited nearly parabolic GRIN profiles. When comparing the two age groups (18- and 39 day-old) there was a significant increase in the central thickness (from 3.61 to 3.74 mm), and in the refractive index of the surface (from 1.362 to 1.366) and the nucleus (from 1.443 to 1.454). The presence of GRIN shifted the spherical aberration (−4.1 µm on average) of the lens towards negative values. Conclusions: The guinea pig lens exhibits a GRIN profile with surface and nucleus refractive indices that increase slightly during the first days of life. GRIN plays a major role in the lens optical properties and should be incorporated into computational guinea pig eye models to study emmetropisation, myopia development and ageing., This work was supported by European Research Council (ERC) Grant Agreement ERC-2011-AdC- 294099; ERC under the European Union’s Horizon 2020 research and innovation programme (H2020-MSCA COFUND-2015 FP-713694, MULTIPLY) and under grant agreement No 779960, IMCUSTOMEYE and No 675137 (MyFUun MSCA ITN); Spanish Government Grant FIS2017-84753-R; Hunter Medical Research Institute G1400967 and the University of Newcastle (FVG 1031537 and SSP).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Contact lenses, the reverse Pulfrich effect, and anti-Pulfrich monovision corrections

  • Rodríguez-López, Víctor
  • Dorronsoro, Carlos
  • Burge, Johannes
16 pags., 9 figs., Interocular differences in image blur can cause processing speed differences that lead to dramatic misperceptions of the distance and three-dimensional direction of moving objects. This recently discovered illusion—the reverse Pulfrich effect—is caused by optical conditions induced by monovision, a common correction for presbyopia. Fortunately, anti-Pulfrich monovision corrections, which darken the blurring lens, can eliminate the illusion for many viewing conditions. However, the reverse Pulfrich effect and the efficacy of anti-Pulfrich corrections have been demonstrated only with trial lenses. This situation should be addressed, for clinical and scientific reasons. First, it is important to replicate these effects with contact lenses, the most common method for delivering monovision. Second, trial lenses of different powers, unlike contacts, can cause large magnification differences between the eyes. To confidently attribute the reverse Pulfrich effect to interocular optical blur differences, and to ensure that previously reported effect sizes are reliable, one must control for magnification. Here, in a within-observer study with five separate experiments, we demonstrate that (1) contact lenses and trial lenses induce indistinguishable reverse Pulfrich effects, (2) anti-Pulfrich corrections are equally effective when induced by contact and trial lenses, and (3) magnification differences do not cause or impact the Pulfrich effect., Te project that gave rise to these results received the support of a fellowship from ”la Caixa” Foundation (ID 100010434; LCF/BQ/DR19/11740032) and Spanish Ministry of Education Grant FPU17/02760 to V.R.L., Spanish Ministry of Science, Innovation, and Universities Grants ISCIII DTS2016/00127, FIS2017-84753-R and CSIC LINKA20122 to C.D., and startup funds from the University of Pennsylvania to J.B.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Optical and visual quality with physical and visually simulated presbyopic multifocal contact lenses

  • Viñas, María
  • Aissati, Sara
  • González-Ramos, Ana
  • Romero, Mercedes
  • Sawides, L.
  • Akondi, Vyas
  • Gambra, Enrique
  • Dorronsoro, Carlos
  • Karkkainen, T.
  • Nankivil, D.
  • Marcos, Susana
16 pags. 6 figs., 1 tab., Purpose: As multifocal contact lenses (MCLs) expand as a solution for presbyopia correction, a better understanding of their optical and visual performance becomes essential. Also, providing subjects with the experience of multifocal vision before contact lens fitting becomes critical, both to systematically test different multifocal designs and to optimize selection in the clinic. In this study, we evaluated the ability of a simultaneous vision visual simulator (SimVis) to represent MCLs. Methods: Through focus (TF) optical and visual quality with a center-near aspheric MCL (low, medium and high near adds) were measured using a multichannel polychromatic Adaptive Optics visual simulator equipped with double-pass, SimVis (temporal multi-plexing), and psychophysical channels to allow measurements on-bench and in vivo. On bench TF optical quality of SimVis-simulated MCLs was obtained from double-pass (DP) images and images of an E-stimulus using artificial eyes. Ten presbyopic subjects were fitted with the MCL. Visual acuity (VA) and DP retinal images were measured TF in a 4.00 D range with the MCL on eye, and through SimVis simulations of the same MCLs on the same subjects. Results: TF optical (on bench and in vivo) and visual (in vivo) quality measurements captured the expected broadening of the curves with increasing add. Root mean square difference between real and SimVis-simulated lens was 0.031/0.025 (low add), 0.025/0.015 (medium add), 0.019/0.011 (high add), for TF DP and TF LogMAR VA, respectively. A shape similarity metric shows high statistical values (lag κ = 0), rho = 0.811/0.895 (low add), 0.792/0.944 (medium add), and 0.861/0.915 (high add) for TF DP/LogMAR VA, respectively. Conclusions: MCLs theoretically and effectively expand the depth of focus. A novel simulator, SimVis, captured the through-focus optical and visual performance of the MCL in most of the subjects. Visual simulators allow subjects to experience vision with multifocal lenses prior to testing them on-eye. Translational Relevance: Simultaneous visual simulators allow subjects to experience multifocal vision non-invasively. We demonstrated equivalency between real multifocal contact lenses and SimVis-simulated lenses. The results suggest that SimVis is a suitable technique to aid selection of presbyopic corrections in the contactology practice., Supported by the European Research Council (ERC-2011-AdC 294099) to SM; Spanish Government (FIS2017-84753R) to SM, and pre-doctoral fellowship (FPU16/01944) to SA; Collaborative agreement with Johnson & Johnson Vision, Inc., Research & Development, Jacksonville, FL, USA.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Testing the effect of ocular aberrations in the perceived transverse chromatic aberration

  • Aissati, Sara
  • Viñas, María
  • Benedi, Clara
  • Dorronsoro, Carlos
  • Marcos, Susana
17 pags., 9 figs., We have measured the ocular transverse chromatic aberration (TCA) in 11 subjects using 2D-two-color Vernier alignment, for two pupil diameters, in a polychromatic adaptive optics (AO) system. TCA measurements were performed for two pupil diameters: for a small pupil (2-mm), referred to as 'optical TCA' (oTCA), and for a large pupil (6-mm), referred to 'perceived TCA' (pTCA). Also, the TCA was measured through both natural aberrations (HOAs) and AO-corrected aberrations. Computer simulations of pTCA incorporated longitudinal chromatic aberration (LCA), the patient's HOAs measured with Hartmann-Shack, and the Stiles-Crawford effect (SCE), measured objectively by laser ray tracing. The oTCA and the simulated pTCA (no aberrations) were shifted nasally 1.20 arcmin and 1.40 arcmin respectively. The experimental pTCA (-0.27 arcmin horizontally and -0.62 vertically) was well predicted (81%) by simulations when both the individual HOAs and SCE were considered. Both HOAs and SCE interact with oTCA, reducing it in magnitude and changing its orientation. The results indicate that estimations of polychromatic image quality should incorporate patient's specific data of HOAs, LCA, TCA & SCE., European Research Council (ERC-2011-AdC 294099); H2020 Marie Skłodowska-Curie Actions (H2020 COFUND Marie Curie 291820 program); Spanish Government (FIS2014-56643R, FIS2017-84753R, FPU16/01944, ISCIII DTS16/00127).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Detecting deformation asymmetries on multiple meridians in an ex vivo keratoconic eye model

  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Martínez-Enríquez, Eduardo
  • Germann, James
  • Palací, J.
  • Pascual, Daniel
  • Muralidharan, Geethika
  • Eliasy, A.
  • Abass, A.
  • Solarski, J.
  • Karnowski, Karol
  • Wojtkowski, Maciej
  • Elsheikh, A.
  • Marcos, Susana
1 pag. -- This is a 2020 ARVO Annual Meeting abstract., Support European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694; European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960; European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137; Spanish government grant FIS2017-84753-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Effect of fixational eye movements in corneal topography measurement with OCT

  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Muralidharan, Geethika
  • Curatolo, Andrea
  • Marcos, Susana
1 pag. -- This is a 2020 ARVO Annual Meeting abstract., Support COFUND Multiply: European Research Council (ERC) under European Union’s Horizon 2020 research and innovation programme H2020-MSCA-COFUND-2015-FP-713694; Spanish government grant FIS2017-84753-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

3D OCT-based geometrical changes of human crystalline lenses during simulated accommodation in a lens stretcher

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Mohamed, Ashik
  • Maceo Heilman, B.
  • Williams, S.
  • Nandyala, S.
  • Ruggeri, Marco
  • Parel, J. M. A.
  • Augusteyn, Robert
  • Ho, Arthur
  • Manns, Fabrice
  • Marcos, Susana
This is a 2020 ARVO Annual Meeting abstract., Support European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137, European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960​, European Project SILKEYE H2020-ERC-2018-ADG Ref. 833106, European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694, Spanish government grant FIS2017-84753-R, NEI Grants: R01EY021834, F31EY021444 (Maceo), P30EY14801 (Center Grant); the Florida Lions Eye Bank; Research to Prevent Blindness; Drs. KR Olsen and ME Hildebrandt, Drs. Raksha Urs and Aaron Furtado, the Henri and Flore Lesieur Foundation (JMP); Hyderabad Eye Research Foundation., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Vision with Multifocal contact lenses in Myopes and Presbyopes

  • Vedhakrishnan, Shrilekha
  • Viñas, María
  • Casado-Moreno, Pilar
  • Benedi, Clara
  • Dorronsoro, Carlos
  • Marcos, Susana
ARVO Annual Meeting Abstract , June 2020, Spanish government grant FIS2017-84753-R, European Project PRESBYOPIA ERC-2011-AdG Ref. 294099, European Project MyFUN H2020MSCA-ITN-2015 Ref. 675137, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

The Reverse Pulfrich effect: depth misperceptions with contact-lens-induced monovision corrections

  • Rodríguez-López, Víctor
  • Burge, Johannes
  • Dorronsoro, Carlos
ARVO Annual Meeting Abstract, June 2020, Support Spanish government FPU Fellowship FPU17/02760, La Caixa Foundation Fellowship LCF/BQ/DR19/11740032, Spanish government grant FIS2017-84753-R, Spanish government FIS2014-56643-R, Spanish Government grant DTS16/127, Spanish Government grant LINKA20122, US NIH grant R01-EY028571, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Vision is protected against blue defocus

  • Benedi, Clara
  • Viñas, María
  • Dorronsoro, Carlos
  • Marcos, Susana
9 pags., 4 figs., Due to chromatic aberration, blue images are defocused when the eye is focused to the middle of the visible spectrum, yet we normally are not aware of chromatic blur. The eye sufers from monochromatic aberrations which degrade the optical quality of all images projected on the retina. The combination of monochromatic and chromatic aberrations is not additive and these aberrations may interact to improve image quality. Using Adaptive Optics, we investigated the optical and visual efects of correcting monochromatic aberrations when viewing polychromatic grayscale, green, and blue images. Correcting the eye’s monochromatic aberrations improved optical quality of the focused green images and degraded the optical quality of defocused blue images, particularly in eyes with higher amounts of monochromatic aberrations. Perceptual judgments of image quality tracked the optical fndings, but the perceptual impact of the monochromatic aberrations correction was smaller than the optical predictions. The visual system appears to be adapted to the blur produced by the native monochromatic aberrations, and possibly to defocus in blue., We acknowledge funding by the European Research Council (ERC Grant Agreement ERC-2011-AdG-294099), FIS2017-84753-R (SM), Alcon Research Institute (SM & EP), and NIH Grant R01EY023385 (EP).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Multifocal acceptance score to evaluate vision: MAS‑2EV

  • Barcala, Xoana
  • Viñas, María
  • Romero, Mercedes
  • Gambra, Enrique
  • Méndez‑González, Juan Miguel
  • Marcos, Susana
  • Dorronsoro, Carlos
15 pags., 10 figs. 3 tabs., We present a new metric (Multifocal Acceptance Score, MAS-2EV) to evaluate vision with presbyopic corrections. The MAS-2EV is based on a set of images representing natural visual scenes at day and night conditions projected in far and near displays, and a near stereo target. Subjects view and score the images through diferent binocular corrections (monofocal corrections at far; bifocal corrections; monovision and modifed monovision) administered with soft contact lenses (in cyclopleged young subjects) or with a binocular simultaneous vision simulator (in presbyopic and cyclopleged young subjects). MAS-2EV scores are visually represented in the form of polygons, and quantifed using diferent metrics: overall visual quality, visual degradation at far, visual beneft at near, near stereo beneft, visual imbalance near-far, overall visual imbalance and a combined overall performance metric. We have found that the MAS-2EV has sufcient repeatability and sensitivity to allow diferentiation across corrections with only two repetitions, and the duration of the psychophysical task (3 min for subject/condition/correction) makes it useable in the clinic. We found that in most subjects binocular bifocal corrections produce the lowest visual imbalance, and the highest near stereo beneft. 46.67% of the subjects ranked binocular bifocal corrections frst, and 46.67% of the subjects ranked monovision frst. MAS-2EV, particularly in combination with visual simulators, can be applied to select prospective presbyopic corrections in patients prior to contact lens ftting or intraocular lens implantation., European Research Council (ERC-2011-AdC 294099 to SM); Spanish Government (FIS2017-84753R to SM, ISCIII DTS16/00127 to CD, DI-15-07753 to JLM, PTQ-15-07432 to EG, PTA2017-13787-I to MR), and Madrid Regional Government (IND2017/BMD-7670 to XB)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Data for the paper “Optical and visual quality of real intraocular lenses physically projected on the patient’s eye”

  • Benedi, Clara
  • Viñas, María
  • Lago, Carmen M.
  • Aissati, Sara
  • Castro, Alberto de
  • Dorronsoro, Carlos
  • Marcos, Susana
The provided Data Set contains an Excel file with the results obtained in the study entitled “Optical and visual quality of the real intraocular lenses physically projected on the patient’s eye”, by C. Benedi-Garcia, M. Vinas, C. M. Lago, S. Aissati, A. de Castro, C. Dorronsoro, S. Marcos, to be published in Biomedical Optics Express (2021)., Visual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient’s eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. IOL-in-cuvette is projected to the pupil’s plane of the subject by using a Rassow system. A second lens, the Rassow lens, compensates for an IOL of 20 D while other powers can be corrected with a Badal system in a 5 D range. The new channel was evaluated by through-focus (TF) optical quality on an artificial eye on bench, and by TF visual acuity in patients, with various IOL designs (monofocal, diffractive trifocal, and refractive extended depth of focus)., Spanish Government FIS2017-84753R. Spanish Government Predoctoral Grant FPU16/01944 to SA. ERC AdG-2018-833106 SILKEYE to SM., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Isolated human crystalline lens three-dimensional shape: A comparison between Indian and European populations

  • Mohamed, Ashik
  • Nandyala, S.
  • Martínez-Enríquez, Eduardo
  • Maceo Heilman, B.
  • Augusteyn, Robert
  • Castro, Alberto de
  • Ruggeri, Marco
  • Parel, J. M. A.
  • Marcos, Susana
  • Manns, Fabrice
6 pags., 2 figs., 2 tabs., There have been many studies on lens properties in specific populations (e.g. in China, Europe, Singapore, etc.) some of which suggest there may be differences between populations. Differences could be caused by ethnic or environmental influences or experimental procedures. The purpose of this study is to evaluate if any differences exist between Indian and European populations in the central geometric and full shape properties of human lenses. Two custom-developed spectral domain optical coherence tomography systems were used to acquire the crystalline lens geometry: one in India (69 lenses from 59 donors) and the other in Spain (24 lenses from 19 donors). The steps for obtaining accurate 3-D models from optical coherence tomography raw images comprised of image segmentation, fan and optical distortion correction, tilt removal and registration. The outcome variables were lens equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, central radius of curvature of the anterior and posterior lens surfaces, lens volume and lens surface area. A mixed effects model by maximum likelihood estimation was used to evaluate the effect of age, population and their interaction (age*population) on lens parameters. After adjusting for age, there were no population differences observed in anterior and posterior radii of curvature, equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, volume and surface area (all p ≥ 0.08). There was also no effect of the interaction term on anterior and posterior radii of curvature, equatorial diameter, lens thickness, anterior and posterior lens thicknesses and their ratio, volume and surface area (all p ≥ 0.06). All central geometric and full shape parameters appeared to be comparable between the European and Indian populations. This is the first study to compare geometric and full shape lens parameters between different populations in vitro., This work was supported by the National Institutes of Health/National Eye Institute [Grants 2R01EY021834 and P30EY14801 (Center Grant)]; the Hyderabad Eye Research Foundation; Ministerio de Educacion y Ciencia, Spain (FIS2017- 84753-R), European Research Council (ERC-2018-AdG-833106) and IMCUSTOMEYE Ref. 779960 (H2020- ICT- 2017-1) to S. Marcos, and European Research Council (ERC) under European Union’s Horizon 2020 research and innovation programme H2020-MSCA COFUND-2015 FP-713694, MULTIPLY(AdC), CSIC ICoop Program, Florida Lions Eye Bank and the Beauty of Sight Foundation, an unrestricted grant from Research to Prevent Blindness to the Department of Ophthalmology, University of Miami and the Henri and Flore Lesieur Foundation (J-M. Parel).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Intraocular photobonding to enable accommodating intraocular lens function

  • Alejandre, Nicolás
  • Gutierrez-Contreras, R.
  • Dorronsoro, Carlos
  • Marcos, Susana
9 pags., 4 figs., Purpose: Accommodating intraocular lenses (A-IOLs) require capturing the ciliary muscle forces. Prior work demonstrated strong photo-initiated bonding between strips of capsular bag and poly(2-hydroxyethyl methacrylate); (pHEMA) polymer in an extraocular setting. We demonstrate that photobonding can be achieved intraocularly. Methods: Phacoemulsification was performed in porcine eyes (<24 hours postmortem). A commercial intraocular lens (IOL; pHEMA-MMA material) was inserted in the capsular bag. Surface contact between the lens and capsular bag was ensured by continuous air infusion into the anterior chamber of the eye, which provided sufficient pressure at the interface, as well as oxygen. The capsular bag and IOL then were stained with 0.1% photosensitizer Rose Bengal (RB) solution. A fiberoptic probe connected to a diode-laser (532 nm) was used to locally irradiate the capsular bag–IOL interface intraocularly. The bonding breaking load was evaluated in a uniaxial stretcher. Results: Photobonding occurred in the 0.8 to 1.6 W/cm irradiance range and 2.5 to 7 minutes irradiation time. Average forces of 0.12 N stretched but did not break the bond. These forces, applied uniaxially, are higher than the summed net accommodating force of the ciliary muscle along the entire equator (0.08 N). In two cases, the zonulae broke before the bonded region. Conclusions: Photobonding between the capsular bag and IOL polymer can be achieved intraocularly, in a procedure compatible with standard cataract surgery. This technique will enable the mechanisms of A-IOLs not to rely on capsular bag integrity or natural haptic fibrosis. Translational Relevance: Intraocular photobonding holds promise to enable operation of A-IOLs to restore accommodation in presbyopia, affecting 100% of the population <45 years old. Intraocular bonding of polymer material to ocular tissue also may find other applications in ophthalmology., This study was funded by the European Research Council under the European Union’s Seventh Framework Programme (FP7/2007-2013)/ERC Grant Agreement ERC-2011-AdG-294099 to SM. The current study was also supported by the Spanish government grants FIS2014-56643-R and FIS2017-84753-R to SM; and the FIS2013-49544-EXP to CD. The authors want to thank the Surface Spectroscopies & Surface Plasmon Photonics Group (Instituto de Estructura de la Materia, CSIC) for technical assistance.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Optical and visual quality of real intraocular lenses physically projected on the patient’s eye

  • Benedi, Clara
  • Viñas, María
  • Lago, Carmen M.
  • Aissati, Sara
  • Castro, Alberto de
  • Dorronsoro, Carlos
  • Marcos, Susana
15 pags., 9 figs., 1 tab., Visual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient’s eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. The IOL is projected on the pupil’s plane of the subject by using a Rassow system. A second lens, the Rassow lens, compensates for an IOL of 20 D while other powers can be corrected with a Badal system within a 5 D range. The new channel was evaluated by through-focus (TF) optical quality in an artificial eye on bench, and by TF visual acuity in patients, with various IOL designs (monofocal, diffractive trifocal, and refractive extended depth of focus)., Funding. Spanish Government (FIS2017-84753R), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Vision with spatial light modulator simulating multifocal contact lenses in an adaptive optics system

  • Vedhakrishnan, Shrilekha
  • Viñas, María
  • Aissati, Sara
  • Marcos, Susana
14 pags., 7 figs., 1 tab., Visual simulators are useful tools to provide patients experience of multifocal vision prior to treatment. In this study, commercially available center-near aspheric multifocal contact lenses (MCLs) of low, medium, and high additions were mapped on a spatial light modulator (SLM) and validated on a bench. Through focus visual acuity (TFVA) was measured in subjects through the SLM and real MCLs on the eye. A correlation metric revealed statistically significant shape similarity between TFVA curves with real and simulated MCLs. A Bland-Altman analysis showed differences within confidence intervals of ±0.01 logMAR for LowAdd/MediumAdd and ±0.06 logMAR for HighAdd. Visual performance with simulated MCLs outperformed real MCLs by ∼20%. In conclusion, SLM captures the profile of center-near MCLs and reproduces vision with real MCLs, revealing that the MCL profile and its interactions with the eye’s optics (and not fitting aspects) account for the majority of the contributions to visual performance with MCLs, This research has received funding from the European Union’s Horizon 2020 Research and Innovation Program, MyFun under the Marie Sklodowska-Curie grant agreement to SV, and H2020-MSCA-IF-GF2019-MYOMICRO-893557 to MV, under the Marie Sklodowska-Curie grant agreement; European Research Council ERC-2019-AdG-833106 H2020 Innovative Action 779960 & Spanish Government FIS2017-84753-R to SM., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Detecting deformation asymmetries on multiple meridians in an ex vivo keratoconic eye model

  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Martínez-Enríquez, Eduardo
  • Germann, James
  • Palací, J.
  • Pascual, Daniel
  • Muralidharan, Geethika
  • Eliasy, A.
  • Abass, A.
  • Solarski, J.
  • Karnowski, Karol
  • Wojtkowski, Maciej
  • Elsheikh, A.
  • Marcos, Susana
ARVO Annual Meeting Abstract, Support European Project COFUND Multiply H-2020-MSCA-COFUND-2015 Ref. 713694; European Project IMCUSTOMEYE H2020-ICT-2017 Ref. 779960; European Project MyFUN H2020-MSCA-ITN-2015 Ref. 675137; Spanish government grant FIS2017-84753-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Perceptual and physical limits to temporal multiplexing simulation of multifocal corrections

  • Dorronsoro, Carlos
  • Rodríguez-López, Víctor
  • Barcala, Xoana
  • Gambra, Enrique
  • Akondi, Vyas
  • Sawides, L.
  • Marrakchi, Y.
  • Lage, Eduardo
  • Geisler, Wilson S.
  • Marcos, Susana
Vancouver Convention Centre, Vancouver, B.C., April 28 – May 2 (2019) . -- ARVO Annual Meeting Abstract 2019, Support Spanish Government RyC-2016-21125, PTQ-15-07432, FPU17/02760, FIS2014-56643-R, FIS2017-84753-R and ISCIII-DTS16-00127, S Madariaga MECD PRX16/00154 + Fulbright CIES FMECD-ST-2016; EU H2020 SME IA GA-739882; EIT Health; ERC-2011-AdC 294099; CAM IND2017/BMD-7670; CAM and Marie Curie Action EU FP7/2007-2013 COFUND 291820, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Testing the effect of ocular aberrations on perceived Transverse Chromatic Aberration

  • Aissati, Sara
  • Viñas, María
  • Benedi, Clara
  • Dorronsoro, Carlos
  • Marcos, Susana
ARVO Annual Meeting Abstract (2019), Support Spanish Government Grant FIS2014-56643-R Spanish Government Grant FIS2017-84753-R European Project Presbyopia ERC-2011-AdG Ref. 294099 Spanish Government Predoctoral Grant FPU16/01944, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Crystalline lens Gradient Index Profile in the guinea pig myopia model

  • Marcos, Susana
  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Revuelta, Luis
  • McFadden, Sally A.
ARVO Annual Meeting Abstract (2019), Support European Research Council ERC-2011-AdG 294099; Spanish Government FIS2014-56643-R, FIS2017-84753-R; H-2020-MSCA-COFUND-2015 713694, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Perceived best focus and visual performance upon induction of astigmatism in presbyopes

  • Benedi, Clara
  • Velasco Ocaña, Miriam
  • Dorronsoro, Carlos
  • Hernández, Martha
  • Marín, Gildas
  • Marcos, Susana
ARVO Annual Meeting Abstract (2019), Support a collaborative agreement with Essilor International, France. Spanish government grant FIS2014-56643-R, Spanish government grant FIS2017-84753-R, European Research Council under the European Union’s Seventh Framework Programme (FP7/2007-2013) ERC-2011-AdG-294099, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Eigenlenses: an eigenvectors-based model for full crystalline lens shape description

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Mohamed, Ashik
  • Ruggeri, Marco
  • Williams, Siobhan
  • Parel, Jean Marie
  • Manns, Fabrice
  • Marcos, Susana
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019., Support Spanish Government Grant FIS2014-56643-R; Spanish Government Grant FIS2017-84753-R; European Project Presbyopia ERC-2011-AdG Ref. 294099; National Eye Institute Grants 2R01EY021834, P30EY14801 (Center Grant); the Hyderabad Eye Research Foundation; Florida Lions Eye Bank and the Beauty of Sight Foundation; Drs KR Olsen and ME Hildebrandt; Drs R Urs and A Furtado; the Henri and Flore Lesieur Foundation (JMP); an unrestricted grant from Research to Prevent Blindness., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Optical and visual quality with physical and visually simulated presbyopic multifocal contact lenses

  • Viñas, María
  • Aissati, Sara
  • González-Ramos, Ana M.
  • Romero, Mercedes
  • Sawides, L.
  • Akondi, Vyas
  • Gambra, Enrique
  • Dorronsoro, Carlos
  • Martínez-Enríquez, Eduardo
  • Karkkainen, T.
  • Nankivil, D.
  • Marcos, Susana
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019, Support European Research Council ERC-2011-AdG-294099; Spanish Government: FIS2017-84753-R, PTQ-15-07432, and ISCIII DTS16/00127; Spanish Goverment predoctoral program FPU16/01944; Collaborative agreement with Johnson & Johnson Vision, Inc., Jacksonville, FL, USA, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Perceptual differences across binocular corrections for presbyopia

  • Barcala, Xoana
  • Viñas, María
  • Gambra, Enrique
  • Marcos, Susana
  • Dorronsoro, Carlos
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019., Support Spanish Government Grant FIS2014-56643-R; FIS2017-84753-R; ISCIII​ DTS16/00127; PTQ-15-07432; CAM IND2017/BMD7670; European Project Presbyopia ERC-2011-AdG 294099, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Assessment of asymmetries in biomechanical properties from corneal deformation imaging

  • Birkenfeld, Judith S.
  • Germann, James
  • Castro, Alberto de
  • Hoz, A. de la
  • Curatolo, Andrea
  • Marcos, Susana
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019, Support European Project Multiply H-2020-MSCA-COFUND-2015 Ref. 713694, Spanish Government Grant FIS2017-84753-R, European Project Presbyopia ERC-2011-AdG Ref. 294099, European Project Imcustomeye H2020-ICT-2017 Ref. 779960, BES-2015-072197, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology

  • Marcos, Susana
  • Martínez-Enríquez, Eduardo
  • Viñas, María
  • Castro, Alberto de
  • Dorronsoro, Carlos
  • Bang, Seung Pil
  • Yoon, Geunyoung
  • Artal, Pablo
32 pags., 10 figs., As the human eye ages, the crystalline lens stiffens (presbyopia) and opacifies (cataract), requiring its replacement with an artificial lens [intraocular lens (IOL)]. Cataract surgery is the most frequently performed surgical procedure in the world. The increase in IOL designs has not been paralleled in practice by a sophistication in IOL selection methods, which rely on limited anatomical measurements of the eye and the surgeon's interpretation of the patient's needs and expectations. We propose that the future of IOL selection will be guided by 3D quantitative imaging of the crystalline lens to map lens opacities, anticipate IOL position, and develop fully customized eye models for ray-tracing-based IOL selection. Conversely, visual simulators (in which IOL designs are programmed in active elements) allow patients to experience prospective vision before surgery and to make more informed decisions about which IOL to choose. Quantitative imaging and optical and visual simulations of postsurgery outcomes will allow optimal treatments to be selected for a patient undergoing modern cataract surgery., The authors have received funding from the following sources: H2020-MSCA-ITN-2015- 675137 IMCUSTOMEYE (S.M.); ERC-2011-AdG-294099 PRESBYOPIA (S.M.); ERC-PoCOCT4IOL (S.M.); ERC-PoC-SimVisSim (S.M.); ERC-2018-AdG-833106-SilkEye (S.M.) and ERC-2013-AdG-339228 SEECAT (P.A.); Spanish Agencia Estatal de Investigación FIS2017- 84753-R (S.M.) and PID2019-105684RB-I00 (P.A.); Fundación Séneca-Agencia de Ciencia y Tecnología de la Región de Murcia 19897/GERM/15 (P.A.); National Institutes of Health/National Eye Institute (G.Y.); Research to Prevent Blindness (G.Y.); and NYSTAR/CEIS/CoE (G.Y.).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Functional integration of eye tissues and refractive eye development: Mechanisms and pathways

  • Summers, Jody A.
  • Schaeffel, Frank
  • Marcos, Susana
  • Wu, Hao
  • Tkatchenko, Andrei V.
15 pags., 3 figs., Refractive eye development is a tightly coordinated developmental process. The general layout of the eye and its various components are established during embryonic development, which involves a complex cross-tissue signaling. The eye then undergoes a refinement process during the postnatal emmetropization process, which relies heavily on the integration of environmental and genetic factors and is controlled by an elaborate genetic network. This genetic network encodes a multilayered signaling cascade, which converts visual stimuli into molecular signals that guide the postnatal growth of the eye. The signaling cascade underlying refractive eye development spans across all ocular tissues and comprises multiple signaling pathways. Notably, tissue-tissue interaction plays a key role in both embryonic eye development and postnatal eye emmetropization. Recent advances in eye biometry, physiological optics and systems genetics of refractive error have significantly advanced our understanding of the biological processes involved in refractive eye development and provided a framework for the development of new treatment options for myopia. In this review, we summarize the recent data on the mechanisms and signaling pathways underlying refractive eye development and discuss new evidence suggesting a wide-spread signal integration across different tissues and ocular components involved in visually guided eye growth., This work was supported in part by the National Institutes of Health grants R01EY09391 (JAS), R01EY023839 (AVT), P30EY019007 (Core Support for Vision Research received by the Department of Ophthalmology, Columbia University), Research to Prevent Blindness (Unrestricted funds received by the Department of Ophthalmology, Columbia University), European Commission grant H2020-MSCA-ITN-2015-675137 (SM), European Research Council grant ERC-2018-ADG-SILKEYE-833106 (SM) and Spanish Government grant FIS 2017-84753-R (SM).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

SimVis simulations of multifocal IOL designs based on public-literature data

  • Sawides, L.
  • Castro, Alberto de
  • Lago, Carmen M.
  • Barcala, Xoana
  • Zaytouny, Amal
  • Marcos, Susana
  • Dorronsoro, Carlos
12 pags., 10 figs., As a large variety of intraocular lens (IOL) designs is commercially available in a growing market, selecting the best IOL for each patient has become a crucial task for a positive surgical outcome. Information about the measured or estimated performance of commercial lenses, as the through-focus modulation transfer function (TF-MTF) at a given frequency and pupil diameter, is routinely published. SimVis Gekko, a see-through simultaneous vision simulator based on temporal multiplexing, allows patients to experience the real world through different multifocal corrections prior to surgery. Implementing the maximum number of commercially available IOL designs into the portfolio of SimVis Gekko simulations is needed to provide a complete experience for the patients. We developed a new method to visually simulate IOL designs using temporal multiplexing, based only on publicly available information (mainly scientific literature or regulatory information), using the TF-MTF at 15cpd as input data to estimate the temporal coefficients that provide the best approximation to the real lens design. We validated the method with synthetic phase maps of equal area segmented bifocal and trifocal multifocal corrections for three pupil diameters of 3mm, 3.75mm and 4.5mm and applied it to three commercially available IOLs (trifocal or extended-depth-of-focus lenses). Through-focus visual acuity (TF-VA) curves were measured in seven patients using the SimVis simulations in the SimVis Gekko and matched, on average, the throughfocus VA measurements in patients with implanted IOLs, reported in the scientific literature (on average logMAR RMS error=0.05, corresponding to less than 3 letters of visual acuity charts)., We acknowledge financial support from the European Research Council ERC-2011-AdC 294099 (SM) from the Spanish Government FIS2017-84753R (SM), ISCIII DTS16/00127 (CD) and from Madrid Regional Government Doctorado Industrial IND2017/BMD-7670 (XB) and IND2018/BMD-9809 (CL)
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Matching convolved images to optically blurred images on the retina

  • Aissati, Sara
  • Benedi, Clara
  • Viñas, María
  • Castro, Alberto de
  • Marcos, Susana
14 pags., 5 figs., Convolved images are often used to simulate the effect of ocular aberrations on image quality, where the retinal image is simulated by convolving the stimulus with the point spread function derived from the subject's aberrations. However, some studies have shown that convolved images are perceived far more degraded than the same image blurred with optical defocus. We hypothesized that the positive interactions between the monochromatic and chromatic aberrations in the eye are lost in the convolution process. To test this hypothesis, we evaluated optical and visual quality with natural optics and with convolved images (on-bench, computer simulations, and visual acuity [VA] in subjects) using a polychromatic adaptive optics system with monochromatic (555 nm) and polychromatic light (WL) illumination. The subject's aberrations were measured using a Hartmann Shack system and were used to convolve the visual stimuli, using Fourier optics. The convolved images were seen through corrected optics. VA with convolved stimuli was lower than VA through natural aberrations, particularly in WL (by 26% in WL). Our results suggest that the systematic decrease in visual performance with visual acuity and retinal image quality by simulation with convolved stimuli appears to be primarily associated with a lack of favorable interaction between chromatic and monochromatic aberrations in the eye., Supported by the Spanish Government (FIS2017-84753R, PID2020-115191RB-I00) to SM; Spanish Government Predoctoral (Grant FPU16/01944) to SA; H2020 Marie Sklodowska-Curie Actions (H2020 MSCA IF GF 2019 MYOMICRO 893557) to MV; European Research Council (ERC-2018-ADG SILKEYE 833106), NIH NIE P30EY 001319; and Unrestricted Funds Research to Prevent Blindness to SM., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Visual performance with multifocal lenses in young adults and presbyopes

  • Vedhakrishnan, Shrilekha
  • Viñas, María
  • Benedi, Clara
  • Casado, Pilar
  • Marcos, Susana
21 pags., 9 figs., 1 tab., A better understanding of visual performance with Multifocal Contact Lenses (MCLs) is essential, both in young eyes, where MCLs may be prescribed to control the progression of myopia wherein the MCLs optics interact with accommodation, and in presbyopes, where MCLs are increasingly used to compensate the lack of accommodation. In this study, we evaluated the through focus visual acuity (TFVA) with center-near MCLs of three additions (low, medium and high) and without an addition (NoLens) in 10 young adults and 5 presbyopes. We studied the effect of accommodation, age and pupil diameter (in cyclopleged subjects) on visual performance. The MCLs produced a small but consistent degradation at far (by 0.925 logMAR, averaged across eyes and conditions) and a consistent benefit at near in young subjects with paralyzed accommodation (by 1.025 logMAR), and in presbyopes with both paralyzed and natural accommodation (by 1.071 logMAR, on average). TFVA in young adults with NoLens and all MCLs showed statistically significant differences (Wilcoxan, p<0.01) between natural and paralyzed accommodation, but not in presbyopes with MCLs. In young adults, VA improved with increasing pupil diameter with the HighAdd MCL (0.08 logMAR shift from 3 to 5-mm pupil size). Visual imbalance (standard deviation of VA across distances) was reduced with MCLs, and decreased significantly with increasing near add. The lowest imbalance occurred in young adults under natural accommodation and was further reduced by 13.33% with MCLs with respect to the NoLens condition. Overall, the visual performance with MCLs in young adults exceeds that in presbyopes at all distances, and was better than 0.00 logMAR over the dioptric range tested. In conclusion, the center-near lenses do not degrade the near high contrast visual acuity significantly but maintains the far vision in young adults, and produce some visual benefit at near in presbyopes., This research has received funding from the European Union’s Horizon 2020 Research and Innovation Program, MyFun under the Marie Sklodowska-Curie grant agreement SV, and H2020-MSCA-IF-GF-2019-MYOMICRO-893557 to MV, under the Marie Sklodowska-Curie grant agreement; European Research Council ERC-2019 SILK-EYE & Spanish Government: FIS2019-84753-R to SM; NEI P35 and the Unrestricted Funds Research to Prevent Blindness, NY., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Understanding In Vivo Chromatic Aberrations in Pseudophakic Eyes Using on Bench and Computational Approaches

  • Viñas, María
  • Castro, Alberto de
  • Dorronsoro, Carlos
  • González-Ramos, Ana
  • Redzovic, Suad
  • Willet, Nicolas
  • Garzon, Nuria
  • Marcos, Susana
16 pags., 8 figs., 2 tabs. -- This article belongs to the Special Issue Ocular Imaging for Eye Care, Diffractive multifocal intraocular lenses (IOLs) modulate chromatic aberration and reduce it at certain distances due to interactions between the refractive and diffractive chromatic components. However, the extent to which computer modeling and on bench measurements of IOL chromatic aberration translate to chromatic aberration in patients implanted with these multifocal IOLs (MIOLs) is not yet fully understood. In this study, we compare the chromatic difference of focus and longitudinal chromatic aberrations in pseudophakic patients implanted with different IOL designs (monofocal and trifocal IOLs) and materials (hydrophobic and hydrophilic), and compared them with predictions from computer eye models and on bench measurements with the same IOLs. Patient data consisted of results from 63 pseudophakic eyes reported in four different studies and obtained psychophysically in the visual testing channel of a custom-developed polychromatic adaptive optics system. Computational predictions were obtained using ray tracing on computer eye models, and modulation transfer function (MTF) on bench measurements on physical eye models. We found that LCA (in vivo/simulated) for far vision was 1.37 ± 0.08 D/1.19 D for monofocal hydrophobic, 1.21 ± 0.08 D/0.88 D for monofocal hydrophilic, 0.99 ± 0.06 D/1.19 D for MIOL hydrophobic, and 0.82 ± 0.05 D/0.88 D for MIOL hydrophilic. For intermediate and near vision, LCA (in vivo/simulated) was 0.67 ± 0.10 D/0.75 D and 0.23 ± 0.08 D/0.19 D for MIOL hydrophobic and 0.27 ± 0.15 D/0.38 D and 0.15 ± 0.15 D/−0.13 D for MIOL hydrophilic, respectively. In conclusion, computational ray tracing and on bench measurements allowed for evaluating in vivo chromatic aberration with different materials and designs for multifocal diffractive intraocular lenses., This research received funding from the European Research Council under the ERC2011-AdG-294099 to S.M. and the H2020-MSCA-IF-GF-2019-MYOMICRO-893557 to M.V.-P.; the Spanish Government grant FIS2017-84753 and PID2020-115191RB-I00 to S.M., and collaborative agreements (2014–2020) with PhyIOL (Liege, Belgium), the National Eye Institute P30 Core Grant EY001319-46 (Center for Visual Science), and Unrestricted grant Research to Prevent Blindness (Flaum Eye Institute)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Visual simulations of presbyopic corrections through cataract opacification

  • Barcala, Xoana
  • Zaytouny, Amal
  • Rego-Lorca, Daniela
  • Sanchez-Quiros, Julia
  • Sanchez-Jean, Ruben
  • Martinez de la Casa, Jose Maria
  • Dorronsoro, Carlos
  • Marcos, Susana
29 pags., To study the viability of visual simulation of presbyopic corrections in patients with cataract, the effect and impact of the cataract on the perceived visual quality of the different simulated presbyopic corrections pre- and post-operatively., This research was supported by Madrid Regional Government IND2017/BMD7670 to XB; IMCUSTOMEYE Ref. 779960 H2020 - EU.2.1.1. Industrial Leadership to SM; SILK-EYE Ref. 833106 Excellent Science – ERC to SM; Spanish Government Grant FIS2017-84753-R to SM; and ISCIII DTS16/00127 to CD., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Multifocal contact lens vision simulated with a clinical binocular simulator

  • Barcala, Xoana
  • Viñas, María
  • Ruiz, Sofia
  • Hidalgo, Fernando
  • Nankivil, Derek
  • Karkkainen, Tom
  • Gambra, Enrique
  • Dorronsoro, Carlos
  • Marcos, Susana
11 pags., 10 figs., 2 tabs., The purpose of this study is to compare the binocular visual perception of participants wearing multifocal contact lenses and these same lens designs viewed through a temporal multiplexing visual simulator., This research has received funding from the European Research Council under the IMCUSTOMEYE Ref. 779,960 H2020 - EU.2.1.1. Industrial Leadership to SM; SILK-EYE Ref. 833,106 Excellent Science – ERC to SM; and the H2020-MSCA-IF-GF-2019-MYOMICRO-893557 to MV. National Eye Institute P30 Core Grant EY001319-46 (Center for Visual Science) and Unrestricted grant Research to Prevent Blindness (Flaum Eye Institute) to SM. This research was supported also from the Spanish Government under the Spanish Government Grant FIS2017-84753-R to SM, and ISCIII DTS16/00127 to CD; Madrid Regional Government IND2017/BMD7670 to XB; and Master Clinical Research Agreement between Johnson and Johnson Vision Care (USA), 2EyesVision, Centro Boston de Optometría and IO-CISC., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Accommodation through simulated multifocal optics

  • Vedhakrishnan, Shrilekha
  • Castro, Alberto de
  • Viñas, María
  • Aissati, Sara
  • Marcos, Susana
16 pags., 7 figs., We evaluated the interaction of multifocal patterns with eye's accommodation. Seven patterns were mapped on the spatial light modulator and the deformable mirror of an adaptive optics visual simulator, and projected onto the subjects' eyes, representing different contact lens designs: NoLens, Bifocal Center Distance (+2.50D), Bifocal Center Near (+2.50D) and Multifocal Center Near-MediumAdd (+1.75D) and Center Near HighAdd (+2.50D), positive and negative spherical aberration (±1µm). The change in spherical aberration and the accommodative response to accommodative demands were obtained from Hartmann-Shack measurements. Positive spherical aberration and Center Distance designs are consistent with a higher accommodative response (p=0.001 & p=0.003): steeper shift of SA towards negative values and lower accommodative lag., Marie Sklodowska-Curie (ADC, H2020-MSCA-IF-GF-2019-MYOMICRO-893557, SV, PID2020-115191); European Research Council (ERC-2019-AdG-833106 H2020); Innovative Action (779960); Spanish Government (FIS2017-84753-R, NIH P30, RPB unrestricted funds to SM), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Convolved vs.Optically blurred images-What is the key reason for the observed differences?

  • Aissati, Sara
  • Viñas, María
  • Benedi, Clara
  • Marcos, Susana
This is a 2021 ARVO Annual Meeting abstract, Purpose : Image convolutions are often used to simulate the effects of ocular aberrations on image quality.We studied potential discrepancies in the image degradation/visual performance using convolved images(viewed through corrected optics)or the real aberrations,in both monochromatic & white light(WL), Support Spanish Government FIS2017-84753R; Guggenheim Fellowship ; Spanish Government Predoctoral Grant FPU16/01944, Marie Curie Fellowship, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Applications of Adaptive Optics Visual Simulators

  • Aissati, Sara
  • Viñas, María
  • Benedi, Clara
  • González-Ramos, Ana M.
  • Vedhakrishnan, Shrilekha
  • Marcos, Susana
XIII Reunión Nacional de Óptica. -- Evento online, 22-24 noviembre 2021, Spanish Government (FIS2014-56643R, FIS2017-84753R, FPU16/01944, ISCIII DTS16/00127); European Research Council (ERC-2011-AdC 294099, ERC-2019-AdG-833106); H2020 Marie Skłodowska-Curie Actions H2020-MSCA (IF-GF-2019-MYOMICRO-893557 & COFUND 291820 program)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Co-axial acoustic-based optical coherence vibrometry probe for the quantification of resonance frequency modes in ocular tissue

  • McAuley, Ryan
  • Nolan, Andrew
  • Curatolo, Andrea
  • Alexandrov, Sergey
  • Zvietcovich, Fernando
  • Varea, Alejandra
  • Marcos, Susana
  • Leahy, Martin
  • Birkenfeld, Judith S.
Artículo con 10 figuras, We present a co-axial acoustic-based optical coherence vibrometry probe (CoA-OCV) for vibro-acoustic resonance quantification in biological tissues. Sample vibrations were stimulated via a loudspeaker, and pre-compensation was used to calibrate the acoustic spectrum. Sample vibrations were measured via phase-sensitive swept-source optical coherence tomography (OCT). Resonance frequencies of corneal phantoms were measured at varying intraocular pressures (IOP), and dependencies on Young¿s Modulus (E), phantom thickness and IOP were observed. Cycling IOP revealed hysteresis. For E = 0.3 MPa, resonance frequencies increased with IOP at a rate of 3.9, 3.7 and 3.5 Hz/mmHg for varied thicknesses and 1.7, 2.5 and 2.8 Hz/mmHg for E = 0.16 MPa. Resonance frequencies increased with thickness at a rate of 0.25 Hz/µm for E = 0.3 MPa, and 0.40 Hz/µm for E = 0.16 MPa. E showed the most predominant impact in the shift of the resonance frequencies. Full width at half maximum (FWHM) of the resonance modes increased with increasing thickness and decreased with increasing E. Only thickness and E contributed to the variance of FWHM. In rabbit corneas, resonance frequencies of 360–460 Hz were observed. The results of the current study demonstrate the feasibility of CoA-OCV for use in future OCT-V studies., The research leading to these results has received funding from: Horizon 2020 European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); European Research Council 2018-ADG-SILKEYE-833106; Spanish Government FIS2017-84753-R, PID2020-115191RB-I00; NIH NIE P30EY 001319; Unrestricted Funds Research to Prevent Blindness, NY; Juan de la Cierva (IJC2018-037508-I); L'Oréal-UNESCO “For Women in Science” Spain; Fundacja na rzecz Nauki Polskiej (MAB/2019/12); Polish National Agency for Academic Exchange, (NAWA ULAM/2020/1/00176).The funding organizations had no role in the design or conduct of this research.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Multifocal contact lens vision simulated with a clinical binocular simulator

  • Barcala, Xoana
  • Viñas, María
  • Ruiz, Sofia
  • Hidalgo, Fernando
  • Nankivil, Derek
  • Karkkainen, Tom
  • Gambra, Enrique
  • Dorronsoro, Carlos
  • Marcos, Susana
Artículo con 10 figuras, Purpose: The purpose of this study is to compare the binocular visual perception of participants wearing multifocal contact lenses and these same lens designs viewed through a temporal multiplexing visual simulator. Methods: Visual performance and perceived visual quality at various distances were obtained in 37 participants wearing soft M−CLs and through the SimVis Gekko programmed with the same lenses. In a pilot study (n = 10) visual performance was measured in terms of LogMAR visual acuity (VA) at far (4 m), intermediate (64 cm) and near (40 cm) distances and through-focus VA (TFVA) curves with the simulated M−CLs. In the follow-up study (n = 27), LogMAR VA at far, intermediate and near distances were measured both with the actual and simulated M−CLs. Perceived visual quality was measured in both studies using the Multifocal Acceptance Score (MAS-2EV), and a Participants Reported Outcomes Vision questionnaire. Differences between the metrics obtained with simulated and actual lenses were obtained. Results: Both actual and simulated M−CLs increased depth-of-focus by a similar amount. Mean LogMAR VA differences with actual and simulated M−CLs ranged between 4 and 6 letters (0.08 ± 0.01, 0.12 ± 0.01 and 0.10 ± 0.01, for far, intermediate and near distances, respectively). MAS-2EV average score differences with actual and simulated M−CLs ranged between −1.00 and + 4.25. Average MAS-2EV scores were not correlated significantly with VA. However, MAS-2EV (average and individual scores) were highly correlated to visual quality questionnaire responses (p < 0.005). Conclusions: A simultaneous vision simulator accurately represented vision with M−CLs both VA at various distances and perceived visual quality, as measured in a clinical setting. The MAS-2EV metric accurately captured participant reported outcomes of standard vision questionnaires. The combination of SimVis Gekko and MAS-2EV has the potential to largely reduce chair time in M−CLs fitting., This research has received funding from the European Research Council under the IMCUSTOMEYE Ref. 779,960 H2020 - EU.2.1.1. In- dustrial Leadership to SM; SILK-EYE Ref. 833,106 Excellent Science – ERC to SM; and the H2020-MSCA-IF-GF-2019-MYOMICRO-893557 to MV. National Eye Institute P30 Core Grant EY001319-46 (Center for Visual Science) and Unrestricted grant Research to Prevent Blindness (Flaum Eye Institute) to SM. This research was supported also from the Spanish Government under the Spanish Government Grant FIS2017- 84753-R to SM, and ISCIII DTS16/00127 to CD; Madrid Regional Gov- ernment IND2017/BMD7670 to XB; and Master Clinical Research Agreement between Johnson and Johnson Vision Care (USA), 2Eye- sVision, Centro Boston de Optometría and IO-CISC
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Defocus flicker of chromatic stimuli deactivates accommodation

  • Rodríguez-López, Víctor
  • Hernandez-Poyatos, Alfonso
  • Dorronsoro, Carlos
12 pags., 7 figs., Tunable lenses, optical elements able to change their optical power within milliseconds, constitute an emerging technology increasingly used in ophthalmic applications. In this study, 25 subjects looked through tunable lenses at a chromatic stimulus to evaluate the perceptual response of the human visual system to periodic changes in defocus of 0.25D of amplitude and 15 Hz of temporal frequency. These defocus changes produce flicker and chromatic distortions that change with the overall level of defocus. The task in this study was to minimize the flicker by varying the average optical power, and it was performed for different myopic and hyperopic starting points. Subjects also performed a blur-minimization task in a black-and-white stimulus of the same geometry. The flicker-minimization task is more repeatable than the blur-minimization task (standard deviations ±0.17D and ±0.49D). The time per repetition of the flicker-minimization task is only 38s. Cycloplegia severely affects the blur-minimization, but not the flicker-minimization task, confirming that defocus flicker deactivates the accommodative system. This discovery can be used to develop new methods for measuring the refractive error of the eye that does not require supervision and can potentially improve existing subjective methods in terms of accuracy, precision, and measurement time., “la Caixa” Foundation (ID 100010434; LCF/BQ/DR19/11740032); Ministerio de Educación y Formación Profesional (FPU17/02760); Ministerio de Ciencia, Innovación y Universidades (FIS2017-84753-R, ISCIII DTS2016/00127)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Spatiotemporal defocus sensitivity function of the human visual system

  • Rodríguez-López, Víctor
  • Geisler, Wilson
  • Dorronsoro, Carlos
17 pags., 7 figs., 3 tabs., Tunable lenses make it possible to measure visual sensitivity to rapid changes in optical power, surpassing the limits imposed by mechanical elements. Using a tunable lens system, we measured, for the first time, the spatiotemporal defocus sensitivity function (STDSF), and the limits of human defocus perception. Specifically, we measured defocus sensitivity using a QUEST adaptive psychophysical procedure for different stimuli (Gabor patches of different spatial frequencies, natural images, and edges) and we developed descriptive models of defocus perception. For Gabor patches, we found on average (across seven subjects) that the maximum sensitivity to defocus is 0.22 D at 14 cpd and 10 Hz, and that the upper limits of sensitivity are 40 cpd and 40 Hz. Our results suggest that accommodation remains fixed while performing the defocus flicker-detection task. These results have implications for new technologies whose working principles make use of fast changes to defocus., “la Caixa” Foundation (ID 100010434; LCF/BQ/DR19/11740032); Ministerio de Educación y Formación Profesional (FPU17/02760); National Institutes of Health (EY02466, EY11747); Ministerio de Ciencia, Innovación y Universidades (FIS2017-84753-R, ISCIII DTS2016/00127)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Monovision Correction Preference and Eye Dominance Measurements

  • Rodríguez-López, Víctor
  • Barcala, Xoana
  • Zaytouny, Amal
  • Dorronsoro, Carlos
  • Peli, Eli
  • Marcos, Susana
12 pags., 8 figs., 1 tab., To propose new methods for eye selection in presbyopic monovision corrections., Supported by “la Caixa” Foundation (ID 100010434; LCF/BQ/DR19/11740032) to V.R.L.; Madrid Regional Government IND2017/BMD7670 to X.B. and A.Z.; Health Institute Carlos III PID2020- 115191RB-I00 to C.D.; National Eye Institute R01-EY23385 to E.P.; Grant FIS2017-84753-R and PID2020-115191RB-I00 (Agencia Estatal de Investigación, Spain) and European Research Council Advanced Grant SILK-EYE Ref. 833106 Excellent Science – ERC, National Eye Institute P30 Core Grant EY001319-46 (Center for Visual Science, University of Rochester, NY) and Unrestricted grant Research to Prevent Blindness (Flaum Eye Institute, University of Rochester, NY) to S.M., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Effect of fixational eye movements in corneal topography measurements with optical coherence tomography

  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Marcos, Susana
15 pags., 7 figs., 1 tab., here is an increasing interest in applying optical coherence tomography (OCT) to quantify the topography of ocular structures. However, in its most usual configuration, OCT data is acquired sequentially while a beam is scanned through the region of interest, and the presence of fixational eye movements can affect the accuracy of the technique. Several scan patterns and motion correction algorithms have been proposed to minimize this effect, but there is no consensus on the ideal parameters to obtain a correct topography. We have acquired corneal OCT images with raster and radial patterns, and modeled the data acquisition in the presence of eye movements. The simulations replicate the experimental variability in shape (radius of curvature and Zernike polynomials), corneal power, astigmatism, and calculated wavefront aberrations. The variability of the Zernike modes is highly dependent on the scan pattern, with higher variability in the direction of the slow scan axis. The model can be a useful tool to design motion correction algorithms and to determine the variability with different scan patterns., Agencia Estatal de Investigación (FIS2017-84753-R, PID2020-115191RB-I00); European Research Council (H2020-ICT-2017 Ref.779960); National Institutes of Health (P30EY 001319,Unrestricted Funds to Research to Prevent Blindness).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Revealing regional variations in scleral shear modulus in a rabbit eye model using multi-directional ultrasound optical coherence elastography

  • Villegas, Lupe
  • Zvietcovich, Fernando
  • Marcos, Susana
  • Birkenfeld, Judith S.
12 pags., 7 figs., The mechanical properties of the sclera play a critical role in supporting the ocular structure and maintaining its shape. However, non-invasive measurements to quantify scleral biomechanics remain challenging. Recently introduced multi-directional optical coherence elastography (OCE) combined with an air-coupled ultrasound transducer for excitation of elastic surface waves was used to estimate phase speed and shear modulus in ex vivo rabbit globes (n = 7). The scleral phase speed (12.1 ± 3.2 m/s) was directional-dependent and higher than for corneal tissue (5.9 ± 1.4 m/s). In the tested locations, the sclera proved to be more anisotropic than the cornea by a factor of 11 in the maximum of modified planar anisotropy coefficient. The scleral shear moduli, estimated using a modified Rayleigh-Lamb wave model, showed significantly higher values in the circumferential direction (65.4 ± 31.9 kPa) than in meridional (22.5 ± 7.2 kPa); and in the anterior zone (27.3 ± 9.3 kPa) than in the posterior zone (17.8 ± 7.4 kPa). The multi-directional scanning approach allowed both quantification and radial mapping of estimated parameters within a single measurement. The results indicate that multi-directional OCE provides a valuable non-invasive assessment of scleral tissue properties that may be useful in the development of improved ocular models, the evaluation of potential myopia treatment strategies, and disease characterization and monitoring., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work has been funded by Spanish Government Grant (PRE2018-086169, FIS2017-84753-R, PID2020-115191RB-I00); European Project H2020 IMCUSTOMEYE (779960); European Research Council (2018-ADG-SILKEYE-833106); Ayudas Ramón y Cajal (RYC2022-037910-I); L’Oréal-UNESCO “For Women in Science” Spain; NIH NEI P30EY 001319; Unrestricted Funds Research to Prevent Blindness., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Effects of Different Scleral Photo-Crosslinking Modalities on Scleral Stiffness and Hydration

  • Villegas, Lupe
  • Germann, James
  • Marcos, Susana
9 pags., 7 figs., The purpose of this study was to evaluate the biomechanical and hydration differences in scleral tissue after two modalities of collagen cross-linking., Supported by Spanish Government Grant (PRE2018-086169 and FIS2017-84753-R); European Research Council (2018-ADGSILKEYE-833106); NIH NEI P30EY 001319; and Unrestricted Funds Research to Prevent Blindness, NY., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A simple computational model for scleral stiffness assessments via air-puff deformation OCT

  • Hoz, A. de la
  • Villegas, Lupe
  • Marcos, Susana
  • Birkenfeld, Judith S.
13 pags., 11 figs., 2 tabs., Introduction: The mechanical properties of the sclera are related to its structural function, and changes to these properties are believed to contribute to pathologies such as myopia. Air-puff deformation imaging is a tool that uses an imaging system coupled with an air-puff excitation source to induce and measure deformation in a tissue in vivo. Typically used for the study of the cornea's mechanical properties and IOP, this tool has been proposed as a method to evaluate scleral stiffness. Methods: In this work, we present a computational model of the rabbit eye to assess scleral deformation under air-puff. Parametric studies were conducted to evaluate the effects of material properties, intraocular pressure, and other parameters on the deformation response. Output from the model was also compared to experimental measurements of air-puff deformation in rabbit eyes under varying IOP. Results: Central deformation response was found to be most influenced by material properties of the sclera (at site of air-puff and posterior), thickness, and IOP, whereas deformation profile was most influenced by material properties. Experimental and simulated IOP dependence were found to be similar (RMSE = 0.13 mm). Discussion: Scleral APDI could be a useful tool for quick in vivo assessment of scleral stiffness., The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. Spanish Government Grant (PRE2018-086169, FIS2017-84753-R, PID2020115191RB-I00); European Project H2020 IMCUSTOMEYE (779960); European Research Council (2018-ADG-SILKEYE833106); Ayudas Ramón y Cajal (RYC2022-037910-I); L’OréalUNESCO “For Women in Science” Spain; NIH NEI P30EY 001319; Unrestricted Funds Research to Prevent Blindness, NY, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Estimation of scleral mechanical properties from air-puff optical coherence tomography

  • Bronte-Ciriza, David
  • Birkenfeld, Judith S.
  • Hoz, A. de la
  • Curatolo, Andrea
  • Germann, James
  • Villegas, Lupe
  • Varea, Alejandra
  • Martínez-Enríquez, Eduardo
  • Marcos, Susana
19 pages, 7 figures, 2 tables, We introduce a method to estimate the biomechanical properties of the porcine sclera in intact eye globes ex vivo, using optical coherence tomography that is coupled with an air-puff excitation source, and inverse optimization techniques based on finite element modeling. Air-puff induced tissue deformation was determined at seven different locations on the ocular globe, and the maximum apex deformation, the deformation velocity, and the arc-length during deformation were quantified. In the sclera, the experimental maximum deformation amplitude and the corresponding arc length were dependent on the location of air-puff excitation. The normalized temporal deformation profile of the sclera was distinct from that in the cornea, but similar in all tested scleral locations, suggesting that this profile is independent of variations in scleral thickness. Inverse optimization techniques showed that the estimated scleral elastic modulus ranged from 1.84 ± 0.30 MPa (equatorial inferior) to 6.04 ± 2.11 MPa (equatorial temporal). The use of scleral air-puff imaging holds promise for non-invasively investigating the structural changes in the sclera associated with myopia and glaucoma, and for monitoring potential modulation of scleral stiffness in disease or treatment., European Research Council (2018-ADG-SILKEYE-833106); Horizon 2020 Framework Programme European Project Multiply (H-2020-MSCACOFUND-2015 Ref. 713694); Spanish Government (FIS2017-84753-R); Horizon 2020 Framework Programme European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); Spanish Government (CSIC JAE Intro Fellowship); L’Oréal-UNESCO “For Women in Science” Spain; Spanish Government Juan de la Cierva-Incorporation Fellowship (IJC2018-037508-I); Fundacja na rzecz Nauki Polskiej (MAB/2019/12); National Agency for Academic Exchange, Polish Government (NAWA ULAM/2020/1/00176), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Eigenlenses: A new model for full crystalline lens shape representation and its applications

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Marcos, Susana
17 pages, 8 figures, 1 table, The crystalline lens is an important optical element in the eye, responsible for focusing, and which experiences significant changes throughout life. The shape of the lens is usually studied only in the optical area (central 4 to 6 mm). However, for a great number of applications, a description of the full shape of the crystalline lens is required. We propose a new method for the representation of the full shape of the crystalline lens, constructed from 3-dimensional optical coherence tomography images of 133 isolated crystalline lenses (0-71 y/o), which we have called eigenlenses. The method is shown to be compact and accurate to describe not only the full shape of the crystalline lens, but also the optical zone in comparison with other methods. We also demonstrate its application to the extrapolation of the full shape of the crystalline lens from in-vivo optical images of the anterior segment of the eye, where only the central part of the lens visible through the pupil is available, and in the generation (synthesis) of realistic full lenses of a given age. The method has critical applications, among others, in improving and evaluating myopia and presbyopia treatments., H2020 European Research Council (H2020-MSCA COFUND-2015 FP-713694, MULTIPLY (AdC));Ministerio de Economía y Competitividad (FIS2017-84753-R); Horizon2020 Framework Programme (IMCUSTOMEYE Ref. 779960 (H2020-ICT- 2017-1)); European Research Council (ERC-2011-AdG-294099); National Institutes of Health (R01EY021834).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

From Astronomy to the clinic: Adaptive Optics based visual simulators

  • Viñas, María
3 pages, 2 figures, Adaptive optics based visual simulators with deformable mirrors, spatial light modulators or optotunable lenses are increasingly used to simulate vision through different complex multifocal lens designs. Their final utility in the clinic relies on their capability to predict visual performance after an ocular surgery., European Research Council (ERC-2011-AdC 294099); H2020 Marie Skłodowska-Curie Actions (H2020 COFUND Marie Curie 291820 program); Spanish Goverment (FIS2014-56643R, FIS2017-84753R, FPU16/01944, ISCIII DTS16/00127); Private company PhysIOL (Collaborative agreement).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Air-Coupled Ultrasonic Optical Coherence Elastography Reveals Protocol-Dependent Corneal Stiffening in Epi-On and Epi-Off Riboflavin Crosslinking

  • Zvietcovich, Fernando
  • Varea, Alejandra
  • Pleshcheva, Vlada
  • Curatolo, Andrea
  • Birkenfeld, Judith S.
  • Marcos, Susana
Purpose: To evaluate the biomechanical impact of corneal crosslinking (CXL) when combining three different ultraviolet A (UV-A) riboflavin (RB) photosensitizers and protocols (Dresden protocol [DP] and accelerated protocol [AP]) using air-coupled ultrasonic optical coherence elastography in ex vivo rabbit corneas., Methods: An air-coupled ultrasound excitation optical coherence elastography system was used to excite the corneal apex and generate Lamb wave propagation along 16 corneal cross-sectional meridians. Measurements were conducted on ex vivo rabbit eyes (n = 45) during three treatment phases: Virgin, after 30 minutes of RB soaking, and after UV-A irradiation. The protocols used include the DP (3 mW/cm2, 30 minutes) and two accelerated protocols (AP-1: 9 mW/cm2, 10 minutes; and AP-2: 30 mW/cm2, 3 minutes). Each protocol was tested with three photosensitizers: epithelium-on (TE), and epithelium-off with hyperosmolar (M) and hypo-osmolar solutions (D). Lamb wave speed and average corneal thickness were calculated for each meridian to estimate meridian-dependent corneal shear modulus. Differences were statistically analyzed using linear mixed-effects regression., Results: The DP-D produced the strongest significant corneal stiffness increase (480.5 kPa; P < 0.001) during the UV irradiation phase, and the most pronounced corneal thinning (186 µm; P < 0.001). DP-TE achieved the next strongest stiffening (309.5 kPa) during UV irradiation, with no significant thickness change. All other protocol–photosensitizer combinations did not achieve significant corneal stiffening except for AP-1-D and AP-2-D during the RB soaking phase., Conclusions: Accelerated protocols did not produce significant corneal stiffening for any RB photosensitizer except when using dextran-based D. DP-D and DP-TE produced the greatest balance between shear modulus increase and corneal thickness decrease, suggesting DP-TE as a potential compromise between biomechanical impact, corneal integrity, and faster postoperative recovery., Translational Relevance: This work quantified the impact of clinically used crosslinking photosensitizers and protocols on corneal stiffening using an air-coupled ultrasound excitation optical coherence elastography, which holds promise for clinical assessments in patients., Supported by the Spanish Government FIS2017-84753-R, PID2020-115191RB-I00, IND2019/BMD-17262; Horizon 2020 European Project Imcustomeye (H2020-ICT-2017 Ref. 779960); NIH NEI P30EY 001319; Unrestricted Funds Research to Prevent Blindness; Ayudas Ramón y Cajal (RYC2022-037910-I); Ayudas Atracción de Talento RyC (20245AT005); Fundacja na rzecz Nauki Polskiej (MAB/2019/12); National Agency for Academic Exchange, Polish Government (NAWA ULAM/2020/1/00176); and Peruvian CONCYTEC-PROCIENCIA N° PE501082168-2023; PE501093888-2024 and N° PE501098889-2025; Wellcome Trust Early Career Award 300307/Z/23/Z; OPTICA Foundation Challenge Award (2023)., Peer reviewed