Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Experimental validations of a tunable-lens-based visual demonstrator of multifocal corrections

  • Akondi, Vyas
  • Sawides, L.
  • Marrakchi, Y.
  • Gambra, Enrique
  • Marcos, Susana
  • Dorronsoro, Carlos
16 pags., 8 figs. 2 tabs., The Simultaneous Vision simulator (SimVis) is a visual demonstrator of multifocal lens designs for prospective intraocular lens replacement surgery patients and contact lens wearers. This programmable device employs a fast tunable lens and works on the principle of temporal multiplexing. The SimVis input signal is tailored to mimic the optical quality of the multifocal lens using the theoretical SimVis temporal profile, which is evaluated from the through-focus Visual Strehl ratio metric of the multifocal lens. In this paper, for the first time, focimeter-verified on-bench validations of multifocal simulations using SimVis are presented. Two steps are identified as being critical to accurate SimVis simulations. Firstly, a new iterative approach is presented that improves the accuracy of the theoretical SimVis temporal profile for three different multifocal intraocular lens designs – diffractive trifocal, refractive segmented bifocal, and refractive extended depth of focus, while retaining a low sampling. Secondly, a fast focimeter is used to measure the step response of the tunable lens, and the input signal is corrected to include the effects of the transient behavior of the tunable lens. It was found that the root-mean-square of the difference between the estimated through-focus Visual Strehl ratio of the multifocal lens and SimVis is not greater than 0.02 for all the tested multifocal designs., Consejería de Educación, Juventud y Deporte of Comunidad de Madrid and the People Programme (Marie Curie Actions) of the European Union’s Seventh Framework Programme (FP7/2007-2013) (n 291820 to VA); EU H2020 SME Innovation Associate (GA-739882); Spanish Government Torres-Quevedo Program (PTQ-15-07432); EIT Health (2017 HS PoC Spain 05); Ministerio de Economía y Competitividad (DTS16-00127); ERC (ERC-2011-AdC 294099); Spanish Government (FIS2014-56643-R, FIS2017-84753-R)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Tunable lenses: Dynamic characterization and fine-tuned control for high-speed applications

  • Dorronsoro, Carlos
  • Barcala, Xoana
  • Gambra, Enrique
  • Akondi, Vyas
  • Sawides, L.
  • Marrakchi, Y.
  • Rodríguez-López, Víctor
  • Benedi, Clara
  • Viñas, María
  • Lage, Eduardo
  • Marcos, Susana
16 pags., 9 figs., 1 tab., Tunable lenses are becoming ubiquitous, in applications including microscopy, optical coherence tomography, computer vision, quality control, and presbyopic corrections. Many applications require an accurate control of the optical power of the lens in response to a time-dependent input waveform. We present a fast focimeter (3.8 KHz) to characterize the dynamic response of tunable lenses, which was demonstrated on different lens models. We found that the temporal response is repetitive and linear, which allowed the development of a robust compensation strategy based on the optimization of the input wave, using a linear time-invariant model. To our knowledge, this work presents the first procedure for a direct characterization of the transient response of tunable lenses and for compensation of their temporal distortions, and broadens the potential of tunable lenses also in high-speed applications., VA and EL acknowledge financial support from Comunidad de Madrid and Marie Curie Action of the European Union FP7/2007-2013 COFUND 291820; XB from Comunidad de Madrid Doctorado Industrial IND2017/BMD-7670; EL from Spanish Government Ramon y Cajal Program RyC-2016-21125; EG from Spanish Government Torres-Quevedo Program PTQ-15-07432; LS from EU H2020 SME Innovation Associate GA-739882; EG from EIT Health; SM from ERC Grant Agreement ERC-2011-AdC 294099 and Spanish Government Grants FIS2014-56643-R; SM and CD from Spanish Government Grant FIS2017-84753-R; and CD from DTS16-00127.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Perceptual and physical limits to temporal multiplexing simulation of multifocal corrections

  • Dorronsoro, Carlos
  • Rodríguez-López, Víctor
  • Barcala, Xoana
  • Gambra, Enrique
  • Akondi, Vyas
  • Sawides, L.
  • Marrakchi, Y.
  • Lage, Eduardo
  • Geisler, Wilson S.
  • Marcos, Susana
Vancouver Convention Centre, Vancouver, B.C., April 28 – May 2 (2019) . -- ARVO Annual Meeting Abstract 2019, Support Spanish Government RyC-2016-21125, PTQ-15-07432, FPU17/02760, FIS2014-56643-R, FIS2017-84753-R and ISCIII-DTS16-00127, S Madariaga MECD PRX16/00154 + Fulbright CIES FMECD-ST-2016; EU H2020 SME IA GA-739882; EIT Health; ERC-2011-AdC 294099; CAM IND2017/BMD-7670; CAM and Marie Curie Action EU FP7/2007-2013 COFUND 291820, Peer reviewed