Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 95
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Brillouin microscopy of collagen crosslinking: Noncontact depth-dependent analysis of corneal elastic modulus

  • Scarcelli, G.
  • Kling, Sabine
  • Quijano, E.
  • Pineda, R.
  • Marcos, Susana
  • Yun, S. H.
Purpose. Corneal collagen crosslinking (CXL) is designed to halt the progression of keratoconus and corneal ectasia by inducing corneal stiffening. However, it currently is difficult to monitor and evaluate CXL outcome objectively due to the lack of suitable methods to characterize corneal mechanical properties. We validated noncontact Brillouin microscopy to quantify corneal mechanical properties before and after CXL. Methods. CXL was performed on fresh porcine eyes using various presoaking times and light doses, with or without epithelial debridement. From Brillouin maps of corneal elastic modulus, stiffness and average modulus of anterior, middle, and posterior stroma were analyzed. Corneal stiffening index (CSI) was introduced as a metric to compare the mechanical efficacy of a given CXL protocol with respect to the standard protocol (30-minute riboflavin presoak, 3 mW/cm2 ultraviolet illumination for 30 minutes). Results. Brillouin corneal stiffness increased significantly (P < 0.001) by epi-off and epi-on CXL. The increase of Brillouin modulus was depth-dependent, indicating that anterior stromal stiffening contributes the most to mechanical outcome. The increase of anterior Brillouin modulus was linearly proportional to the light dose (R2 > 0.98). Compared to the standard epi-off procedure, a typical epi-on procedure resulted in a third of stiffness increase in porcine corneas (CSI = 33). Conclusions. Brillouin microscopy allowed imaging and quantifying CXL-induced mechanical changes without contact in a depth-dependent manner at high spatial resolution. This technique may be useful to evaluate the mechanical outcomes of CXL procedures, to compare different crosslinking agents, and for real-time monitoring of CXL in clinical and experimental settings. © 2013 The Association for Research in Vision and Ophthalmology, Inc., Supported by the Harvard Clinical and Translational Science Center (NIH UL1-RR025758), American Society for Laser Medicine and Surgery, National Institutes of Health (P41-EB015903), National Science of Foundation (CBET-0853773), Spanish Government (FIS2008-02065, FIS2011-25637), and the European Research Council (ERC-AdG-294099)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Experimental simulation of simultaneous vision

  • Gracia, Pablo de
  • Dorronsoro, Carlos
  • Sánchez-González, Alvaro
  • Sawides, L.
  • Marcos, Susana
Purpose. To present and validate a prototype of an optical instrument that allows experimental simulation of pure bifocal vision. To evaluate the influence of different power additions on image contrast and visual acuity. Methods. The instrument provides the eye with two superimposed images, aligned and with the same magnification, but with different defocus states. Subjects looking through the instrument are able to experience pure simultaneous vision, with adjustable refractive correction and addition power. The instrument is used to investigate the impact of the amount of addition of an ideal bifocal simultaneous vision correction, both on image contrast and on visual performance. The instrument is validated through computer simulations of the letter contrast and by equivalent optical experiments with an artificial eye (camera). Visual acuity (VA) was measured in four subjects (age: 34.3 ± 3.4 years; spherical error: -2.1 ± 2.7 diopters [D]) for low and high contrast letters and different amounts of addition. Results. The largest degradation in contrast and visual acuity (~25%) occurred for additions around ±2 D, while additions of ±4 D produced lower degradation (14%). Low additions (1-2 D) result in lower VA than high additions (3-4 D). Conclusions. A simultaneous vision instrument is an excellent tool to simulate bifocal vision and to gain understanding of multifocal solutions for presbyopia. Simultaneous vision induces a pattern of visual performance degradation, which is well predicted by the degradation found in image quality. Neural effects, claimed to be crucial in the patients' tolerance of simultaneous vision, can be therefore compared with pure optical effects. Copyright 2013 The Association for Research in Vision and Ophthalmology, Inc., Supported by Spanish Government Grant FIS2011-25637 and European Advanced Grant ERC-2011-AdG-294099 to SM., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Static and dynamic crystalline lens accommodation evaluated using quantitative 3-D OCT

  • Gambra, Enrique
  • Ortiz, Sergio
  • Pérez Merino, Pablo
  • Gora, Michalina
  • Wojtkowski, Maciej
  • Marcos, Susana
Custom high-resolution high-speed anterior segment spectral domain Optical Coherence Tomography (OCT) provided with automatic quantification and distortion correction algorithms was used to characterize three-dimensionally (3-D) the human crystalline lens in vivo in four subjects, for accommodative demands between 0 to 6 D in 1 D steps. Anterior and posterior lens radii of curvature decreased with accommodative demand at rates of 0.73 and 0.20 mm/D, resulting in an increase of the estimated optical power of the eye of 0.62 D per diopter of accommodative demand. Dynamic fluctuations in crystalline lens radii of curvature, anterior chamber depth and lens thickness were also estimated from dynamic 2-D OCT images (14 Hz), acquired during 5-s of steady fixation, for different accommodative demands. Estimates of the eye power from dynamical geometrical measurements revealed an increase of the fluctuations of the accommodative response from 0.07 D to 0.47 D between 0 and 6 D (0.044 D per D of accommodative demand). A sensitivity analysis showed that the fluctuations of accommodation were driven by dynamic changes in the lens surfaces, particularly in the posterior lens surface. © 2013 Optical Society of America., The authors acknowledge funding from Predoctoral fellowship CSIC-I3P2006 to EG; FNP Ventures Program co-financed by the EU Funds to MG; EURYI-01/2008-PL (EURHORCs) to MW; MICINN FIS2011-02065 to SM. The research leading to these results has received funding from the European Research Council under the European Union's Seventh Framework Program (FP/2007-2013) / ERC Grant Agreement n. [294099] to SM. The authors acknowledge technical hardware and software support of Ireneusz Grulkowski and Maciej Szkulmowski from NCU Toruń., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Aberrometry in patients implanted with accommodative intraocular lenses

  • Pérez Merino, Pablo
  • Birkenfeld, Judith S.
  • Dorronsoro, Carlos
  • Ortiz, Sergio
  • Durán, Sonia
  • Jiménez-Alfaro, Ignacio
  • Marcos, Susana
Purpose To evaluate the objective accommodative response, change of aberrations, and depth of focus in eyes implanted with the Crystalens accommodative intraocular lens (IOL) at different accommodative demands. Design Prospective, observational study. Methods Eleven cataract patients (22 eyes) who underwent implantation of a Crystalens accommodative IOL, and control groups of 9 normal subjects (17 eyes) and 17 pseudophakic patients (17 eyes) implanted with monofocal IOLs were evaluated. A custom-developed laser ray tracing aberrometer was used to measure the optical aberrations. The monochromatic wave aberrations were described using a sixth-order Zernike polynomial expansion. Measurements were obtained under dilated and natural viewing conditions (for accommodative efforts ranging from 0 to 2.5 diopters [D]). The accommodative response was obtained by analyzing changes in paraxial defocus (associated to changes in defocus) and by evaluating the differences in the effective defocus (associated with defocus, spherical aberrations, and pupil diameter) with the accommodative demand. Depth of focus was estimated from through-focus objective optical quality. Results Wave aberration measurements were highly reproducible. Vertical trefoil (Z3 -3) was the predominant higher-order aberration in the Crystalens group and significantly higher (P <.0001) than in the young group, but similar to the monofocal IOL group. The coma root mean square also was higher (P <.005) in the Crystalens group than in the young group. On average, the defocus term (Z2 0), astigmatism, or higher-order aberrations did not change systematically with accommodative demand in Crystalens eyes. As found for paraxial defocus, the effective defocus in Crystalens eyes did not show significant differences between conditions: 0.34 ± 0.48 D (far), 0.32 ± 0.50 D (intermediate), and 0.34 ± 0.44 D (near). Depth of focus was statistically significantly higher in the Crystalens eyes than in the control groups. Conclusions The accommodative response of eyes implanted with the Crystalens accommodative IOLs, measured objectively using laser ray tracing aberrometry, was lower than 0.4 D in all eyes. Several subjects showed changes in astigmatism, spherical aberration, trefoil, and coma with accommodation, which must arise from geometrical and alignment changes in the lens with accommodative demand. Pseudoaccommodation from increased depth of focus may contribute to near vision functionality in Crystalens-implanted patients. © 2014 by elsevier inc. all rights reserved., Supported by Grant FP7/2007-2013 the European Research Council under the European Union’s Seventh Framework Programme; Grant Agreement 294099 from the European Research Council (S.M.); Grant FIS2011-25637 (S.M.) from the Spanish government; and JAE-Pre Program from the CSIC Junta de Ampliacio´n de Estudios (J.B.)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Contribution of shape and gradient refractive index to the spherical aberration of isolated human lenses

  • Birkenfeld, Judith S.
  • Castro, Alberto de
  • Marcos, Susana
Purpose. To estimate the contribution of 3-dimensional (3D) lens geometry and gradient refractive index (GRIN) to the lens spherical aberration (SA) with age. Methods. A total of 35 donor human lenses (19-71 years) were imaged with 3D-spectral optical coherence tomography (sOCT). Paraxial and nonparaxial back focal length were measured with laser ray tracing (LRT). The parameters of a 4-variable 3D GRIN model were reconstructed from the data using a global search algorithm. Spherical aberration was calculated for GRIN lenses and their corresponding homogeneous lenses. Results. Lens thickness and radii of curvature increased significantly with age. Negative anterior conic constant shifted toward more-positive values (slope: 0.228, P < 0.001), whereas posterior values remained almost constant (slope: 0.0275, P = 0.002). We found a minor decrease and a small significant increase of nucleus and surface refractive index, respectively. The GRIN meridional power exponent had a tendency to increase, indicating a flattening of GRIN distribution, whereas the axial exponent remained almost constant. We did not find a significant age-dependence of the equivalent index. The back focal length had a significant increase with age (P < 0.001). The SA shifted toward less-negative values (slope: 0.0249, P < 0.001) at higher rates when considering the reconstructed GRIN (slope: 0.041, P < 0.001). Conclusions. Three-dimensional sOCT and LRT allowed reconstruction of lens geometry and GRIN in isolated lenses. The constancy of the GRIN axial power exponent, and the opposite slopes of surface and nucleus indices with age, explain the minor variations of the average index. Both geometrical changes and increase in the GRIN meridional power exponent contribute to the age-dependent shift of negative SA. © 2014 The Association for Research in Vision and Ophthalmology, Inc., Supported by Spanish Government Grant FIS2011-25637 (SM); European Research Council ERC-AdG-294099 (SM); Consejo Superior de Investigaciones Cient´ıficas Junta de Ampliacion de ´ Estudios (CSIC JAE)-Pre Program (JB); CSIC i-LINKþ 2012, iLINKþ0609 (SM). The research leading to these results has received funding from the European Research Council under the European Union’s Seventh Framework Programme (FP7/2007- 2013)/ERC Grant Agreement 294099., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

OCT 3-D surface topography of isolated human crystalline lenses

  • Sun, M.
  • Birkenfeld, Judith S.
  • Castro, Alberto de
  • Ortiz, Sergio
  • Marcos, Susana
15 pags.; 10 figs.; 1 tab.; OCIS codes: (110.4500) Optical coherence tomography; (100.2960) Image analysis; (200.4560) Visual optics, aging changes., © 2014 Optical Society of America. Quantitative 3-D Optical Coherence Tomography was used to measure surface topography of 36 isolated human lenses, and to evaluate the relationship between anterior and posterior lens surface shape and their changes with age. All lens surfaces were fitted to 6th order Zernike polynomials. Astigmatism was the predominant surface aberration in anterior and posterior lens surfaces (accounting for ~55% and ~63% of the variance respectively), followed by spherical terms, coma, trefoil and tetrafoil. The amount of anterior and posterior surface astigmatism did not vary significantly with age. The relative angle between anterior and posterior surface astigmatism axes was on average 36.5 deg, tended to decrease with age, and was >45 deg in 36.1% lenses. The anterior surface RMS spherical term, RMS coma and 3rd order RMS decreased significantly with age. In general, there was a statistically significant correlation between the 3rd and 4th order terms of the anterior and posterior surfaces. Understanding the coordination of anterior and posterior lens surface geometries and their topographical changes with age sheds light into the role of the lens in the optical properties of the eye and the lens aging mechanism., This study has been funded by Spanish Government Grant FIS2011-25637 (SM), European Research Council ERC-2011 AdG-294099 (SM), Marie Curie ActionsNetworks of Initial Training (ITN) FP7-PEOPLE-2010-ITN 264605 (OpAL-Optical and adaptational limits of vision) (MS), Consejo Superior de Investigaciones Científicas Junta de Ampliación de Estudios (CSIC JAE)-Pre Program (JB). The research leading to these results has received funding from the European Research Council under the European Union’s Seventh Framework Programme (FP7/2007-2013)/ERC Grant Agreement 294099., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Astigmatism of the ex vivo human lens: Surface and gradient refractive index age-dependent contributions

  • Birkenfeld, Judith S.
  • Castro, Alberto de
  • Marcos, Susana
7 págs.; 5 figs., © 2015 The Association for Research in Vision and Ophthalmology, Inc. PURPOSE. We estimated the contribution of the gradient refractive index (GRIN) and lens surfaces to lens astigmatism and lens astigmatic angle as a function of age in human donor lenses. METHODS. Human lenses were imaged, ex vivo, with 3D-spectral optical coherence tomography (OCT) and their back focal length was measured using laser ray tracing. The contribution of lens surfaces and GRIN to lens astigmatism were evaluated by computational ray tracing on the GRIN lens and a homogenous equivalent index lens. Astigmatism magnitude and relative astigmatic angle of and between lens surfaces, GRIN lens, and lens with homogeneous refractive index were evaluated, and all results were correlated with age. RESULTS. The magnitude of astigmatism in the anterior lens surface decreased with age (slope = -0.005 diopters [D]/y; r = 0.397, P =0.018). Posterior surface astigmatism and lens astigmatism were not age-dependent. Presence of GRIN did not alter significantly the magnitude or axis of the lens astigmatism. The astigmatism of GRIN lens and lens with homogeneous refractive index correlated with anterior lens surface astigmatism (GRIN, P = 3.9E - 6, r = 0.693; equivalent refractive index lens, P = 4.1E - 4, r = 0.565). The astigmatic angle of posterior surface, GRIN lens, and homogeneous refractive index lens did not change significantly with age. CONCLUSIONS. The axis of lens astigmatism is close to the astigmatic axis of the anterior lens surface. Age-related changes in lens astigmatism appear to be related to changes in the anterior lens astigmatism. The influence of the GRIN on lens astigmatism and the astigmatic axis is minor., Supported by Spanish Government Grant FIS2011-25637 (SM), Consejo Superior de Investigaciones Científicas Junta de Ampliacion de Estudios (CSIC JAE)-Pre Program (JB), CSIC i-LINKþ 2012, iLINKþ0609 (SM). The research leading to these results has received funding from the European Research Council under the European Union’s Seventh Framework Programme (FP7/2007-2013)/ERC Grant Agreement 294099 (SM)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Longitudinal chromatic aberration of the human eye in the visible and near infrared from wavefront sensing, double-pass and psychophysics

  • Viñas, María
  • Dorronsoro, Carlos
  • Cortés, Daniel
  • Pascual, Daniel
  • Marcos, Susana
15 págs.; 7 figs.; 1 tab.; OCIS codes: (260.0260) Physical optics; (330.0330) Vision, color, and visual optics; (330.4875) Optics of physiological systems; (330.5370) Physiological optics; (220.1010) Aberrations (global); (220.1080) Active or adaptive optics., © 2015 Optical Society of America. Longitudinal Chromatic Aberration (LCA) influences the optical quality of the eye. However, the reported LCA varies across studies, likely associated to differences in the measurement techniques. We present LCA measured in subjects using wavefront sensing, double-pass retinal images, and psychophysical methods with a custom-developed polychromatic Adaptive Optics system in a wide spectral range (450-950 nm), with control of subjects’ natural aberrations. LCA measured psychophysically was significantly higher than that from reflectometric techniques (1.51 D vs 1.00 D in the 488-700 nm range). Ours results indicate that the presence of natural aberrations is not the cause for the discrepancies across techniques., This research has received funding from the European Research Council under the European Union’s Seventh Framework Program (FP/2007-2013) / ERC Grant Agreement. [ERC-2011- AdC 294099]. This study was also supported by Spanish Government grant FIS2011-25637 to SM, CSIC JAE-Pre programs & MICINN FPU Predoctoral Fellowship to MV, and CSIC JAE-Tec program to DC., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Impact of astigmatism and high-order aberrations on subjective best focus

  • Marcos, Susana
  • Velasco Ocaña, Miriam
  • Dorronsoro, Carlos
  • Sawides, L.
  • Hernández, M.
  • Marín, Gildas
12 págs.; 9 figs.; 1 tab., © 2015 ARVO. We studied the role of native astigmatism and ocular aberrations on best-focus setting and its shift upon induction of astigmatism in 42 subjects (emmetropes, myopes, hyperopes, with-the-rule [WTR] and against-the-rule [ATR] myopic astigmats). Stimuli were presented in a custom-developed adaptive optics simulator, allowing correction for native aberrations and astigmatism induction (+1 D; 6-mm pupil). Best-focus search consisted on randomized-step interleaved staircase method. Each subject searched best focus for four different images, and four different conditions (with/without aberration correction, with/without astigmatism induction). The presence of aberrations induced a significant shift in subjective best focus (0.4 D; p < 0.01), significantly correlated (p = 0.005) with the best-focus shift predicted from optical simulations. The induction of astigmatism produced a statistically significant shift of the best-focus setting in all groups under natural aberrations (p = 0.001), and in emmetropes and in WTR astigmats under corrected aberrations (p < 0.0001). Best-focus shift upon induced astigmatism was significantly different across groups, both for natural aberrations and AO-correction (p < 0.0001). Best focus shifted in opposite directions in WTR and ATR astigmats upon induction of astigmatism, symmetrically with respect to the best-focus shift in nonastigmatic myopes. The shifts are consistent with a bias towards vertical and horizontal retinal blur in WTR and ATR astigmats, respectively, indicating adaptation to native astigmatism., The research leading to these results has received funding from the European Research Council under the European Union’s Seventh Framework Programme (FP/2007-2013)/ERC Grant Agreement n. [ERC-2011- AdC 294099]. This study was supported by grants FIS2011-24637 to SM and a collaborative research project funded by Essilor International. Optometric examinations were performed in the Faculty of Optometry Clinic of the University Complutense de Madrid (Madrid, Spain). GM and MH work for Essilor International., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

In vivo subjective and objective longitudinal chromatic aberration after bilateral implantation of the same design of hydrophobic and hydrophilic intraocular lenses

  • Viñas, María
  • Dorronsoro, Carlos
  • Garzón, N.
  • Poyales, F.
  • Marcos, Susana
10 págs.; 5 figs.; 3 tabs., Purpose To measure the longitudinal chromatic aberration in vivo using psychophysical and wavefront-sensing methods in patients with bilateral implantation of monofocal intraocular lenses (IOLs) of similar aspheric design but different materials (hydrophobic Podeye and hydrophilic Poday). Setting Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain. Design Prospective observational study. Methods Measurements were performed with the use of psychophysical (480 to 700 nm) and wavefront-sensing (480 to 950 nm) methods using a custom-developed adaptive optics system. Chromatic difference-of-focus curves were obtained from best-focus data at each wavelength, and the longitudinal chromatic aberration was obtained from the slope of linear regressions to those curves. Results The longitudinal chromatic aberration from psychophysical measurements was 1.37 diopters (D) ± 0.08 (SD) (hydrophobic) and 1.21 ± 0.08 D (hydrophilic). From wavefront-sensing, the longitudinal chromatic aberration was 0.88 ± 0.07 D and 0.73 ± 0.09 D, respectively. At 480 to 950 nm, the longitudinal chromatic aberration was 1.27 ± 0.09 D (hydrophobic) and 1.02 ± 0.13 D (hydrophilic). The longitudinal chromatic aberration was consistently higher in eyes with the hydrophobic IOL than in eyes with the hydrophilic IOL (a difference of 0.16 D and 0.15 D, respectively). Similar to findings in young phakic eyes, the longitudinal chromatic aberration from the psychophysical method was consistently higher than from wavefront-sensing, by 0.48 D (35.41%) for the hydrophobic IOL and 0.48 D (39.43%) for the hydrophilic IOL. Conclusion Longitudinal chromatic aberrations were smaller with hydrophilic IOLs than with hydrophobic IOLs of the same design. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned., Supported by PhysIOL, Liege, Belgium, European Research Council-2011-AdC 294099 (Dr. Marcos), Spanish Government grant FIS2011-25637 (Dr. Marcos), Consejo Superior de Investigaciones Cientıficas Junta de Ampliacion de Estudios-Preprograms, and Ministerio de Ciencia e Innovacion Formacion de Profesotado Universitario predoctoral fellowship (Dr. Vinas)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

OCT-based crystalline lens topography in accommodating eyes

  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Martínez-Enríquez, Eduardo
  • Marcos, Susana
16 págs. 12 figs.; 3 tabs.; OCIS codes: (110.4500) Optical coherence tomography; (120.6650) Surface measurements, figure; (110.6880) Three-dimensional image acquisition; (100.2960) Image analysis; (330.7327) Visual optics, ophthalmic instrumentation; (330.7322) Visual optics, accommodation; (200.4560) Visual optics, aging changes., Custom Spectral Domain Optical Coherence Tomography (SD-OCT) provided with automatic quantification and distortion correction algorithms was used to measure anterior and posterior crystalline lens surface elevation in accommodating eyes and to evaluate relationships between anterior segment surfaces. Nine young eyes were measured at different accommodative demands. Anterior and posterior lens radii of curvature decreased at a rate of 0.78 ± 0.18 and 0.13 ± 0.07 mm/D, anterior chamber depth decreased at 0.04 ± 0.01 mm/D and lens thickness increased at 0.04 ± 0.01 mm/D with accommodation. Threedimensional surface elevations were estimated by subtracting best fitting spheres. In the relaxed state, the spherical term accounted for most of the surface irregularity in the anterior lens (47%) and astigmatism (70%) in the posterior lens. However, in accommodated lenses astigmatism was the predominant surface irregularity (90%) in the anterior lens. The RMS of high-order irregularities of the posterior lens surface was statistically significantly higher than that of the anterior lens surface (x2.02, p<0.0001). There was significant negative correlation in vertical coma (Z31) and oblique trefoil (Z33) between lens surfaces. The astigmatic angle showed high degree of alignment between corneal surfaces, moderate between corneal and anterior lens surface (~27 deg), but differed by ~80 deg between the anterior and posterior lens surfaces (including relative anterior/posterior lens astigmatic angle shifts, 10-20 deg). © 2015 Optical Society of America, This research has received funding from the European Research Council under the European Union’s Seventh Framework Program (FP/2007-2013) / ERC Grant Agreement. [ERC-2011- AdC 294099]. This study was also supported by Spanish Government grant FIS2011-25637 and FIS2014-56643-R to SM. The authors indicate the following financial disclosure(s): Spanish patent P201130685:, Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Single neural code for blur in subjects with different interocular optical blur orientation

  • Radhakrishnan, Aiswaryah
  • Sawides, L.
  • Dorronsoro, Carlos
  • Peli, E.
  • Marcos, Susana
13 págs.; 5 figs., © 2015 ARVO. The ability of the visual system to compensate for differences in blur orientation between eyes is not well understood. We measured the orientation of the internal blur code in both eyes of the same subject monocularly by presenting pairs of images blurred with real ocular point spread functions (PSFs) of similar blur magnitude but varying in orientations. Subjects assigned a level of confidence to their selection of the best perceived image in each pair. Using a classification-images–inspired paradigm and applying a reverse correlation technique, a classification map was obtained from the weighted averages of the PSFs, representing the internal blur code. Positive and negative neural PSFs were obtained from the classification map, representing the neural blur for best and worse perceived blur, respectively. The neural PSF was found to be highly correlated in both eyes, even for eyes with different ocular PSF orientations (rPos = 0.95; rNeg = 0.99; p < 0.001). We found that in subjects with similar and with different ocular PSF orientations between eyes, the orientation of the positive neural PSF was closer to the orientation of the ocular PSF of the eye with the better optical quality (average difference was ∼10°), while the orientation of the positive and negative neural PSFs tended to be orthogonal. These results suggest a single internal code for blur with orientation driven by the orientation of the optical blur of the eye with better optical quality., The authors acknowledge the funding received from the European Research Council under the European Union’s Seventh Framework Programme (FP7/2007- 2013) / ERC Grant Agreement n8 294099 (SM), Spanish Government grant FIS2011-264605 (SM), the 7th Framework Programme of the European Community through the Marie Curie Initial Training Network OpAL (OpAL is an Initial Training Network funded by the European Commission under the Seventh Framework Programme (PITN-GA-2010- 264605, AR) and USA NIH grant R01EY05957 (EP)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Toward new engagement paradigms for intraocular lenses: Light-initiated bonding of capsular bag to lens materials

  • Marcos, Susana
  • Alejandre, Nicolás
  • Lamela, Jorge
  • Dorronsoro, Carlos
  • Kochevar, I.E.
8 págs.; 5 figs., © 2015 The Association for Research in Vision and Ophthalmology, Inc. PURPOSE. Successful intraocular lens procedures, that is, implantation of accommodating intraocular lenses (A-IOL), require firm engagement of the IOL haptics to the capsular bag. We evaluated the use of photochemical bonding to engage IOL materials to the capsular bag. METHODS. Freshly enucleated eyes of New Zealand rabbits were used in two types of photobonding experiments using Rose Bengal (RB) photoinitiation and green light (532-nm) irradiation. First, RB-stained capsular bag strips were photobonded ex vivo to IOL polymer [poly(2-hydroxyethyl methacrylate) pHEMA] strips in an atmosphere of air and of nitrogen. Second, IOLs were implanted intracapsularly and photobonded intraocularly. Irradiation times were between 30 and 180 seconds, and laser irradiance was between 0.25 and 0.65 W/cm2. The strength of the bonding was tested using a custom-developed uniaxial extensiometry system and the breakage load (the load that caused breakage per bonded area) was calculated. RESULTS. The breakage load of ex vivo capsule–pHEMA bonds increased exponentially with irradiation time, using 0.45 W/cm2. In air, the average breakage load across all conditions was 1 g/mm2 and 1.6 times lower than that in a nitrogen atmosphere. Intraocularly, RB-stained IOLs were strongly photobonded to the capsule bag with breakage loads > 0.8 g/mm2. CONCLUSIONS. Breakage of the photobonded linkage between IOL material and capsular bag required loads substantially greater than the maximum force of ciliary muscle, suggesting that this technology may introduce a new paradigm for engagement of A-IOLs. The bonding produced in air was stronger than that in nitrogen atmosphere, suggesting that oxygen is involved in the chemical mechanism for photobonding., Supported by European Research Council (ERC) EU Seventh Framework Program (FP/2007-2013)/ERC grant agreement, ERC- 2011-AdC 294099 (SM), Spanish Government Grants FIS2011- 25637 (SM) and FIS2013-49544-EXP (CD), and Juan de la Cierva postdoctoral fellowship (JL)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Corneal biomechanical response following collagen cross-linking with Rose Bengal-green light and riboflavin-UVA

  • Bekesi, Nandor
  • Kochevar, Irene E.
  • Marcos, Susana
10 págs.; 9 figs. ; Open Access funded by Creative Commons Atribution Licence 4.0, To compare the biomechanical corneal response of two different corneal cross-linking (CXL) treatments, rose bengal¿green light (RGX) and riboflavin-UVA (UVX), using noninvasive imaging., Supported by the European Research Council under the European Union’s Seventh Framework Program ERC Advanced Grant agreement no. 294099; Comunidad de Madrid and EU Marie Curie COFUND program (FP7/2007-2013/REA 291820); and the Spanish Government Grant FIS2014-56643-R., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Differences in visual quality with orientation of a rotationally asymmetric bifocal intraocular lens design

  • Radhakrishnan, Aiswaryah
  • Dorronsoro, Carlos
  • Marcos, Susana
12 págs.; 13 figs., Purpose To evaluate visual and perceptual performance for different orientations of a rotationally asymmetric bifocal intraocular lens (IOL) (M-Plus) simulated optically using a simultaneous vision simulator. Setting Instituto de Optica, Madrid, Spain. Design Prospective observational study. Methods Perceptual quality and decimal high-contrast visual acuity (HCVA) was measured under cycloplegia for 8 orientations of the asymmetric bifocal IOL phase pattern at far, intermediate, and near distances simulated with a simultaneous vision simulator using face images and tumbling E targets. The preferred orientation at each distance was calculated as the centroid of the data for 8 orientations. The visual Strehl value was calculated using the subjects' ocular aberrations and multifocal pattern at each orientation. Optical predictions were obtained by implementing a differential visual Strehl values–based ideal observer model. Results The study comprised 20 subjects (aged 21 to 62 years). Horizontal orientation (near segment at 0 or 180 degrees ± 45 [SD]) was preferred by 14 subjects and by 13 subjects at far and near distances, respectively; 8 subjects showed strong orientation preferences. The mean difference in preferred orientation between far and near was 27 ± 22 degrees. No significant differences in HCVA were observed. Optical predictions correlated strongly and significantly with measurements (far r = 0.71, near r = 0.62; P < .0001). The mean difference between measurement and simulation in the preferred orientation was 28 ± 29 degrees at far and 36 ± 28 degrees at near. Conclusions The perception varied for different orientations of an asymmetric bifocal IOL design tested using a simultaneous vision simulator. Optimum orientation was driven by interactions of the design with the eye's optical aberrations. Financial Disclosure None of the authors has a financial or proprietary interest in any material or method mentioned. Q 2016 ASCRS and ESCRS, Funding provided by the European Research Council under the European Union’s Seventh Framework Programme (FP7/2007- 2013)/ERC Grant Agreement number 294099 (Dr. Marcos), Spanish Government grant FIS2011-264605 and FIS2014-56643-R (Dr. Marcos), the 7th Framework Programme of the European Community through the Marie Curie Initial Training Network OpAL (OpAL is an Initial Training Network funded by the European Commission under the Seventh Framework Programme), (PITN-GA-2010- 264605, Dr. Radhakrishnan), and Oculentis GmBH, Germany., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Full 3-D OCT-based pseudophakic custom computer eye model

  • Sun, M.
  • Pérez Merino, Pablo
  • Martínez-Enríquez, Eduardo
  • Velasco Ocaña, Miriam
  • Marcos, Susana
15 págs.; 8 figs.; 4 tabs. ; OCIS codes: (110.4500) Optical coherence tomography; (200.4560) Optical data processing; (220.1010) Aberrations (global); (330.7326) Visual optics, modeling., We compared measured wave aberrations in pseudophakic eyes implanted with aspheric intraocular lenses (IOLs) with simulated aberrations from numerical ray tracing on customized computer eye models, built using quantitative 3-D OCT-based patient-specific ocular geometry. Experimental and simulated aberrations show high correlation (R = 0.93; p<0.0001) and similarity (RMS for high order aberrations discrepancies within 23.58%). This study shows that full OCT-based pseudophakic custom computer eye models allow understanding the relative contribution of optical geometrical and surgically-related factors to image quality, and are an excellent tool for characterizing and improving cataract surgery. ©2016 Optical Society of America, This research has received funding from the European Research Council under the European Union’s Seventh Framework Program (FP/2007-2013) / ERC Grant Agreement. [ERC-2011- AdC 294099], from Marie Curie Actions-Networks of Initial Training (ITN) FP7-PEOPLE-2010-ITN 264605 (OpAL-Optical and adaptational limits of vision), and from Spanish Government grants FIS2011-25637 and FIS2014-56643-R to SM. The authors indicate the following financial disclosure(s): Spanish patent: Procedure to calibrate and correct the scan distortion of an optical coherence tomography system, P201130685 (Sergio Ortiz, Susana Marcos, Damian Siedlecki, and Carlos Dorronosoro)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Material properties from air puff corneal deformation by numerical simulations on model corneas

  • Bekesi, Nandor
  • Dorronsoro, Carlos
  • Hoz, A. de la
  • Marcos, Susana
19 págs.; 11 figs.; 2 tabs., Objective To validate a new method for reconstructing corneal biomechanical properties from air puff corneal deformation images using hydrogel polymer model corneas and porcine corneas. Methods Air puff deformation imaging was performed on model eyes with artificial corneas made out of three different hydrogel materials with three different thicknesses and on porcine eyes, at constant intraocular pressure of 15 mmHg. The cornea air puff deformation was modeled using finite elements, and hyperelastic material parameters were determined through inverse modeling, minimizing the difference between the simulated and the measured central deformation amplitude and central-peripheral deformation ratio parameters. Uniaxial tensile tests were performed on the model cornea materials as well as on corneal strips, and the results were compared to stress-strain simulations assuming the reconstructed material parameters. Results The measured and simulated spatial and temporal profiles of the air puff deformation tests were in good agreement (< 7% average discrepancy). The simulated stress-strain curves of the studied hydrogel corneal materials fitted well the experimental stress-strain curves from uniaxial extensiometry, particularly in the 0-0.4 range. Equivalent Young?s moduli of the reconstructed material properties from air-puff were 0.31, 0.58 and 0.48 MPa for the three polymer materials respectively which differed < 1% from those obtained from extensiometry. The simulations of the same material but different thickness resulted in similar reconstructed material properties. The air-puff reconstructed average equivalent Young?s modulus of the porcine corneas was 1.3 MPa, within 18% of that obtained from extensiometry. Conclusions Air puff corneal deformation imaging with inverse finite element modeling can retrieve material properties of model hydrogel polymer corneas and real corneas, which are in good correspondence with those obtained from uniaxial extensiometry, suggesting that this is a promising technique to retrieve quantitative corneal biomechanical properties., This work was supported by the European Research Council under the European Union’s Seventh Framework Program ERC Advanced Grant agreement no. 294099 (erc.europa.eu) to SM; Comunidad de Madrid and EU Marie Curie COFUND program (FP7) 291820 (mvisionconsortium.org/) to NB; Ministerio de Economia y Competitividad Grant FIS2014-56643-R (www.mineco.gob.es) to SM; Ministerio de Economia y Competitividad Grant FIS2013-49544-EXP (www.mineco.gob.es) to CD; Ministerio de Economia y Competitividad FPI Fellowship BES-2015-072197 (www.idi.mineco.gob.es) to AdlH., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Optical coherence tomography based estimates of crystalline lens volume, equatorial diameter, and plane position

  • Martínez-Enríquez, Eduardo
  • Sun, M.
  • Velasco Ocaña, Miriam
  • Birkenfeld, Judith S.
  • Pérez Merino, Pablo
  • Marcos, Susana
11 págs.; 8 figs. ; Open Access funded by Creative Commons Atribution Licence 4.0, PURPOSE. Measurement of crystalline lens geometry in vivo is critical to optimize performance of state-of-the-art cataract surgery. We used custom-developed quantitative anterior segment optical coherence tomography (OCT) and developed dedicated algorithms to estimate lens volume (VOL), equatorial diameter (DIA), and equatorial plane position (EPP). METHODS. The method was validated ex vivo in 27 human donor (19-71 years of age) lenses, which were imaged in three-dimensions by OCT. In vivo conditions were simulated assuming that only the information within a given pupil size (PS) was available. A parametric model was used to estimate the whole lens shape from PS-limited data. The accuracy of the estimated lens VOL, DIA, and EPP was evaluated by comparing estimates from the whole lens data and PS-limited data ex vivo. The method was demonstrated in vivo using 2 young eyes during accommodation and 2 cataract eyes. RESULTS. Crystalline lens VOL was estimated within 96% accuracy (average estimation error across lenses ± standard deviation: 9.30 ± 7.49 mm). Average estimation errors in EPP were below 40 ± 32 lm, and below 0.26 ± 0.22 mm in DIA. Changes in lens VOL with accommodation were not statistically significant (2-way ANOVA, P = 0.35). In young eyes, DIA decreased and EPP increased statistically significantly with accommodation (P < 0.001) by 0.14 mm and 0.13 mm, respectively, on average across subjects. In cataract eyes, VOL = 205.5 mm3, DIA = 9.57 mm, and EPP = 2.15 mm on average. CONCLUSIONS. Quantitative OCT with dedicated image processing algorithms allows estimation of human crystalline lens volume, diameter, and equatorial lens position, as validated from ex vivo measurements, where entire lens images are available., Supported by Ministerio de Educación y Ciencia, Spain, grants FIS2011-25637 and FIS2014-56643, European Research Council grant ERC-2011-AdG-294099 (SM), and Marie Curie ITN grant FP7- PEOPLE-2010-ITN 264605 (MS)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Perceived image quality with simulated segmented bifocal corrections

  • Dorronsoro, Carlos
  • Radhakrishnan, Aiswaryah
  • Gracia, Pablo de
  • Sawides, L.
  • Marcos, Susana
12 págs.; 8 figs.; OCIS codes: (330.0330) Vision, color, and visual optics; (330.4300) Vision system - noninvasive assessment; (330.4460) Ophthalmic optics and devices; (330.4595) Optical effects on vision; (330.7327); Visual optics, ophthalmic instrumentation., Bifocal contact or intraocular lenses use the principle of simultaneous vision to correct for presbyopia. A modified two-channel simultaneous vision simulator provided with an amplitude transmission spatial light modulator was used to optically simulate 14 segmented bifocal patterns (+ 3 diopters addition) with different far/near pupillary distributions of equal energy. Five subjects with paralyzed accommodation evaluated image quality and subjective preference through the segmented bifocal corrections. There are strong and systematic perceptual differences across the patterns, subjects and observation distances: 48% of the conditions evaluated were significantly preferred or rejected. Optical simulations (in terms of through-focus Strehl ratio from Hartmann-Shack aberrometry) accurately predicted the pattern producing the highest perceived quality in 4 out of 5 patients, both for far and near vision. These perceptual differences found arise primarily from optical grounds, but have an important neural component. © 2016 Optical Society of America, European Research Council (ERC) (ERC-AdG-294099) and Spanish Government. Plan Nacional de I+D+i (FIS2011-264605, FIS2014-56643-R) to SM; EU FP7 Marie Curie Initial Training Network OpAL (PITN-GA-2010-264605) to AR; CSIC JAE-Pre Program to PdG; Spanish Government. MEyC FPI Predoctoral Fellowship to LS., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Portable simultaneous vision device to simulate multifocal corrections

  • Dorronsoro, Carlos
  • Radhakrishnan, Aiswaryah
  • Alonso-Sanz, J. R.
  • Pascual, Daniel
  • Velasco Ocaña, Miriam
  • Pérez Merino, Pablo
  • Marcos, Susana
7 págs.; 6 figs. ; OCIS codes: (330.0330) Vision, color, and visual optics; (330.4300) Vision system - noninvasive assessment; (330.4460) Ophthalmic optics and devices; (330.4595) Optical effects on vision; (330.7327) Visual optics, ophthalmic instrumentation., Multifocal lenses are increasingly used solutions for presbyopia, the age-related loss of crystalline lens focus ability. These lenses work by the principle of simultaneous vision, superimposing focused and defocused images on the retina. Providing the experience of simultaneous vision to a patient before permanent implantation of a multifocal lens is a recognized unmet need to increase the patient’s confidence and optimize the lens selection. We developed a hand-held, see-through multifocal vision simulator based on temporal multiplexing of a tunable lens. The device was calibrated and validated using focimetry and Hartmann–Shack aberrometry revealing high reproducibility of the through-focus multifocal energy distribution and high optical quality. We measured visual acuity and perceptual quality on nine cyclopeged patients with three monofocal, two bifocal, and two trifocal corrections with different far/intermediate/ near energy distributions simulated using the device. Visual performance and perceptual quality with multifocal corrections varied across patients, although they were more uniform across distances than monofocal corrections. Among the bifocal and trifocal designs, a trifocal with more energy at far was the most frequently identified as providing better quality. The simultaneous vision simulator proved a promising compact tool to study visual performance with multifocal corrections and to select the lens design best suited for each patient, alternative to costly and bulky adaptive optics based devices. © 2016 Optical Society of America, European Research Council (ERC) (ERC-2011- AdG-294099); Ministerio de Economía y Competitividad (MINECO) (FIS2011-264605, FIS2014-56643-R); Seventh Framework Programme (FP7) (PITN-GA-2010-264605)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Biomechanical changes after in vivo collagen cross-linking with rose bengal–green light and riboflavin-UVA

  • Bekesi, Nandor
  • Gallego-Muñoz, Patricia
  • Ibares-Frías, L.
  • Pérez Merino, Pablo
  • Martínez-García, M.C.
  • Kochevar, Irene E.
  • Marcos, Susana
9 pags., 6 figs., 2 tabs. -- Open Access funded by Creative Commons Atribution Licence 4.0, PURPOSE. To compare corneal biomechanical properties after in vivo and ex vivo cross-linking (CXL) using rose bengal–green light (RGX) or riboflavin-UVA (UVX). METHODS. Corneas of 30 rabbits were treated in vivo by the two CXL modalities monolaterally (Group 1) or bilaterally (Group 2). Rabbits in Group 1 were euthanized 1 month after treatments and in Group 2 two months after treatment. Ex vivo CXL was also performed. Eyes were measured by Scheimpflug air puff corneal deformation imaging (Corvis ST) under constant IOP. Corneal deformation parameters were assessed. Inherent corneal biomechanical properties were estimated using inverse finite element modeling. RESULTS. Peak to peak distance decreased 16% 2 months after RGX, and 4% and 20% 1 and 2 months after UVX, respectively. The equivalent Young’s modulus (Eeq) increased relative to the control during the post treatment period for both RGX and UVX. The Eeq increased by factors of 3.4 (RGX) and 1.7 (UVX) 1 month and by factors of 10.7 (RGX) and 7.3 (UVX) 2 months after treatment. However, the Eeq values for ex vivo CXL were much greater than produced in vivo. The ex vivo Eeq was greater than the 1-month in vivo values by factors of 8.1 (RGX) and 9.1 (UVX) and compared with 2 month by factors of 2.5 (RGX) and 2.1 (UVX). CONCLUSIONS. These results indicate that corneal stiffness increases after CXL, and further increases as a function of time after both RGX and UVX. Also, while biomechanical properties determined after ex vivo CXL are indicative of corneal stiffening, they may not provide entirely accurate information about the responses to CXL in vivo., Supported by the European Research Council under the European Union's Seventh Framework Program ERC Advanced Grant agreement no. 294099; Comunidad de Madrid and EU Marie Curie COFUND program (FP7/2007-2013/REA 291820); and the Spanish Government Grant FIS2014-56643-R., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Comparison of vision through surface modulated and spatial light modulated multifocal optics

  • Viñas, María
  • Dorronsoro, Carlos
  • Radhakrishnan, Aiswaryah
  • Benedi, Clara
  • LaVilla, Edward Anthony
  • Schwiegerling, Jim
  • Marcos, Susana
14 pags., 8 figs. -- OCIS codes: (260.0260) Physical optics; (330.0330) Vision, color, and visual optics; (330.4875) Optics of physiological systems; (330.5370) Physiological optics; (220.1010) Aberrations (global); (220.1080) Active or adaptive optics, Spatial-light-modulators (SLM) are increasingly used as active elements in adaptive optics (AO) systems to simulate optical corrections, in particular multifocal presbyopic corrections. In this study, we compared vision with lathe-manufactured multi-zone (2-4) multifocal, angularly and radially, segmented surfaces and through the same corrections simulated with a SLM in a custom-developed two-active-element AO visual simulator. We found that perceived visual quality measured through real manufactured surfaces and SLM-simulated phase maps corresponded highly. Optical simulations predicted differences in perceived visual quality across different designs at Far distance, but showed some discrepancies at intermediate and near., This research has received funding from the European Research Council ERC-2011-AdG- 294099. This study was also supported by Spanish Government grants FIS2014-56643-R to SM, and CSIC JAE Predoctoral Programs & MICINN FPU Predoctoral fellowship to MV., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Evaluation of the true wavefront aberrations in eyes implanted with a rotationally asymmetric multifocal intraocular lens

  • Akondi, Vyas
  • Pérez Merino, Pablo
  • Martínez-Enríquez, Eduardo
  • Dorronsoro, Carlos
  • Alejandre, Nicolás
  • Jiménez-Alfaro, Ignacio
  • Marcos, Susana
12 pags., 5+3 figs. -- Open Access funded by Creative Commons Atribution Licence 4.0, PURPOSE: Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye. METHODS: The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL. RESULTS: Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction. CONCLUSIONS: Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality., Supported by Consejería de Educación, Juventud y Deporte of Comunidad de Madrid and the People Programme (Marie Curie Actions) of the European Union’s Seventh Framework Programme (FP7/2007-2013) under REA grant agreement no. 291820 to VA; ERC Grant Agreement [ERC-2011-AdG 294099] and Spanish Government Grants FIS2011-25637 and FIS2014-56643-R to SM., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

In vivo measurement of longitudinal chromatic aberration in patients implanted with trifocal diffractive intraocular lenses

  • Viñas, María
  • González-Ramos, Ana
  • Dorronsoro, Carlos
  • Akondi, Vyas
  • Garzón, N.
  • Poyales, F.
  • Marcos, Susana
11 pags., 1-3 figs., 1 tab., PURPOSE: To measure the longitudinal chromatic aberration (LCA) by both psychophysical methods and in vivo double-pass retinal imaging in patients bilaterally implanted with trifocal diffractive intraocular lenses (IOLs). METHODS: Measurements were performed with a polychromatic adaptive optics system provided with a supercontinuum laser, a Hartmann-Shack wavefront sensor, a deformable mirror, a motorized Badal system, a pupil monitoring system, a double-pass retinal imaging channel, and a psychophysical channel with monochromatically illuminated stimuli. Ten patients (20 eyes) bilaterally implanted with hydrophilic trifocal diffractive IOLs (POD F [FINeVision]; PhysIOL, Liege, Belgium) participated in the study. Measurements were performed in both eyes at three different viewing distances (0.00, +1.75, and +3.50 diopters [D]). Subjective best focus of monochromatic stimuli at five wavelengths (480 to 700 nm) was obtained using the Badal system. Best focused images of through-focus double-pass image series were obtained at three wavelengths (480 to 700 nm). LCA was computed from chromatic difference of focus curves (objective and subjective) as the difference between 480 and 700 nm at near, intermediate, and far. RESULTS: The average subjective LCA was 0.82 ± 0.05 D for far, 0.27 ± 0.15 D for intermediate, and 0.15 ± 0.15 D for near. The average objective LCA was 0.72 ± 0.10 D for far, 0.19 ± 0.15 D for intermediate, and 0.07 ± 0.17 D for near. CONCLUSIONS: Objective LCA was lower than subjective LCA, which was in agreement with previous studies on patients with phakic and monofocal IOLs. In vivo measurements of LCA enable understanding of the relative contribution of refractive and diffractive LCA and will eventually optimize IOL designs to improve polychromatic image quality., Supported by European Research Council ERC-2011-AdG-294099; Spanish Government FIS2014; collaborative agreement with PhysIOL (Liege, Belgium)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

OCT-based full crystalline lens shape change during accommodation in vivo

  • Martínez-Enríquez, Eduardo
  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Marcos, Susana
16 pags., 7 figs. -- OCIS codes: (110.4500) Optical coherence tomography; (110.6880) Three-dimensional image acquisition; (330.7322) Visual optics, accommodation; (100.2960) Image analysis; (330.7327) Visual optics, ophthalmic instrumentation, The full shape of the accommodating crystalline lens was estimated using custom three-dimensional (3-D) spectral OCT and image processing algorithms. Automatic segmentation and distortion correction were used to construct 3-D models of the lens region visible through the pupil. The lens peripheral region was estimated with a trained and validated parametric model. Nineteen young eyes were measured at 0-6 D accommodative demands in 1.5 D steps. Lens volume, surface area, diameter, and equatorial plane position were automatically quantified. Lens diameter & surface area correlated negatively and equatorial plane position positively with accommodation response. Lens volume remained constant and surface area decreased with accommodation, indicating that the lens material is incompressible and the capsular bag elastic., European Research Council under the European Union’s Seventh Framework Program (FP/2007-2013) / ERC Grant Agreement (ERC-2011-AdG- 294099); Spanish Government (FIS2011-25637); Spanish Government (FIS2014-56643-R)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Role of parafovea in blur perception

  • Venkataraman, A. P.
  • Radhakrishnan, Aiswaryah
  • Dorronsoro, Carlos
  • Lundström, L.
  • Marcos, Susana
7 pags., 7 figs. -- Open Access funded by Creative Commons Atribution Licence 4.0, The blur experienced by our visual system is not uniform across the visual field. Additionally, lens designs with variable power profile such as contact lenses used in presbyopia correction and to control myopia progression create variable blur from the fovea to the periphery. The perceptual changes associated with varying blur profile across the visual field are unclear. We therefore measured the perceived neutral focus with images of different angular subtense (from 4° to 20°) and found that the amount of blur, for which focus is perceived as neutral, increases when the stimulus was extended to cover the parafovea. We also studied the changes in central perceived neutral focus after adaptation to images with similar magnitude of optical blur across the image or varying blur from center to the periphery. Altering the blur in the periphery had little or no effect on the shift of perceived neutral focus following adaptation to normal/blurred central images. These perceptual outcomes should be considered while designing bifocal optical solutions for myopia or presbyopia., This work was supported by the European Research Council under the 7th Framework Programme through the Marie Curie Initial Training Network OpAL (PITNGA- 2010-264605), the Swedish Research Council (621-2011-4094), European Union’s Seventh Framework Programme (FP7/2007-2013), ERC Grant Agreement (ERC-2011- AdC 294099), Spanish Government grants FIS2011-25637 and FIS2014-56643., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Temporal multiplexing to simulate multifocal intraocular lenses: theoretical considerations

  • Akondi, Vyas
  • Dorronsoro, Carlos
  • Gambra, Enrique
  • Marcos, Susana
16 pags., 10 figs., 1 tab. -- OCIS codes: (330.0330) Vision, color, and visual optics; (330.7327) Visual optics, ophthalmic instrumentation; (330.5370) Physiological optics; (220.1010) Aberrations (global); (220.1080) Active or adaptive optics., Fast tunable lenses allow an effective design of a portable simultaneous vision simulator (SimVis) of multifocal corrections. A novel method of evaluating the temporal profile of a tunable lens in simulating different multifocal intraocular lenses (M-IOLs) is presented. The proposed method involves the characteristic fitting of the through-focus (TF) optical quality of the multifocal component of a given M-IOL to a linear combination of TF optical quality of monofocal lenses viable with a tunable lens. Three different types of M-IOL designs are tested, namely: segmented refractive, diffractive and refractive extended depth of focus. The metric used for the optical evaluation of the temporal profile is the visual Strehl (VS) ratio. It is shown that the time profiles generated with the VS ratio as a metric in SimVis resulted in TF VS ratio and TF simulated images that closely matched the TF VS ratio and TF simulated images predicted with the M-IOL. The effects of temporal sampling, varying pupil size, monochromatic aberrations, longitudinal chromatic aberrations and temporal dynamics on SimVis are discussed., Consejería de Educación, Juventud y Deporte of Comunidad de Madrid and the People Programme (Marie Curie Actions) of the European Union’s Seventh Framework Programme (FP7/2007-2013) under REA grant agreement (n 291820); Ministerio de Economía y Competitividad (DTS16- 00127); Spanish Government Torres-Quevedo Program (PTQ-15-07432); EIT Health e.V. Grant agreement (HS-2016-SPAIN-03); ERC Grant Agreement (ERC-2011-AdC 294099); Spanish Government Grant (FIS2014-56643-R)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Testing vision with angular and radial multifocal designs using Adaptive Optics

  • Viñas, María
  • Dorronsoro, Carlos
  • González, Verónica
  • Cortés, Daniel
  • Radhakrishnan, Aiswaryah
  • Marcos, Susana
12 pags., 12 figs., Multifocal vision corrections are increasingly used solutions for presbyopia. In the current study we have evaluated, optically and psychophysically, the quality provided by multizone radial and angular segmented phase designs. Optical and relative visual quality were evaluated using 8 subjects, testing 6 phase designs. Optical quality was evaluated by means of Visual Strehl-based-metrics (VS). The relative visual quality across designs was obtained through a psychophysical paradigm in which images viewed through 210 pairs of phase patterns were perceptually judged. A custom-developed Adaptive Optics (AO) system, including a Hartmann-Shack sensor and an electromagnetic deformable mirror, to measure and correct the eye¿s aberrations, and a phase-only reflective Spatial Light Modulator, to simulate the phase designs, was developed for this study. The multizone segmented phase designs had 2¿4 zones of progressive power (0 to +3D) in either radial or angular distributions. The response of an ¿ideal observer¿ purely responding on optical grounds to the same psychophysical test performed on subjects was calculated from the VS curves, and compared with the relative visual quality results. Optical and psychophysical pattern-comparison tests showed that while 2-zone segmented designs (angular & radial) provided better performance for far and near vision, 3- and 4-zone segmented angular designs performed better for intermediate vision. AO-correction of natural aberrations of the subjects modified the response for the different subjects but general trends remained. The differences in perceived quality across the different multifocal patterns are, in a large extent, explained by optical factors. AO is an excellent tool to simulate multifocal refractions before they are manufactured or delivered to the patient, and to assess the effects of the native optics to their performance., This research has been funded by the European Research Council under the European Union’s Seventh Framework Program (FP/2007-2013)/ERC Grant Agreement [ERC-2011-AdC 294099]. This study was also supported by Spanish Government grants FIS2011-25637 & FIS2014-56643-R to SM and CSIC JAE-Pre programs & MICINN FPU Predoctoral Fellowship to MV., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Three-dimensional OCT based Guinea pig eye model: Relating morphology and optics

  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Martínez-Enríquez, Eduardo
  • Revuelta, Luis
  • McFadden, Sally A.
  • Marcos, Susana
12 pags., 6 figs., 3 tabs. -- OCIS codes: (110.4500) Optical coherence tomography, (110.6880) Three-dimensional image acquisition, (100.2960) Image analysis, (330.7327) Visual optics, ophthalmic instrumentation, (330.7324) Visual optics, comparative animal models, (330.5370) Physiological optics, Custom Spectral Optical Coherence Tomography (SOCT) provided with automatic quantification and distortion correction algorithms was used to measure the 3-D morphology in guinea pig eyes (n = 8, 30 days; n = 5, 40 days). Animals were measured awake in vivo under cyclopegia. Measurements showed low intraocular variability (<4% in corneal and anterior lens radii and <8% in the posterior lens radii, <1% interocular distances). The repeatability of the surface elevation was less than 2 µm. Surface astigmatism was the individual dominant term in all surfaces. Higher-order RMS surface elevation was largest in the posterior lens. Individual surface elevation Zernike terms correlated significantly across corneal and anterior lens surfaces. Higher-order-aberrations (except spherical aberration) were comparable with those predicted by OCT-based eye models., European Research Council under the European Union´s Seventh Framework Program (FP/2007-2013;) / ERC Grant Agreement [ERC-2011-AdC-294099], and Spanish Government grant FIS2011-25637; and FIS2014-56643-R to SM., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Vision science and adaptive optics, the state of the field

  • Marcos, Susana
  • Werner, John S.
  • Burns, Stephen A.
  • Merigan, William H.
  • Artal, Pablo
  • Atchison, David A.
  • Sincich, Lawrence C.
Susana Marcos et al. -- 31 pags., 13 figs., Adaptive optics is a relatively new field, yet it is spreading rapidly and allows new questions to be asked about how the visual system is organized. The editors of this feature issue have posed a series of question to scientists involved in using adaptive optics in vision science. The questions are focused on three main areas. In the first we investigate the use of adaptive optics for psychophysical measurements of visual system function and for improving the optics of the eye. In the second, we look at the applications and impact of adaptive optics on retinal imaging and its promise for basic and applied research. In the third, we explore how adaptive optics is being used to improve our understanding of the neurophysiology of the visual system., John S. Werner: NIH Grants R01 EY 024239, AG04058, P-30 EY012576 and Research to Prevent Blindness. Susana Marcos: European Research Council under the European Union’s Seventh Framework Program (FP/2007–2013)/ERC Grant Agreement [ERC- 2011-AdC 294099]. Spanish Government Grants FIS2011-25637 & FIS2014-56643-R, Spanish Government FPU and FPI Predoctoral Fellowships, CSIC JAE-Pre program., Pablo Artal: European Research Council Advanced Grant ERC-2013-AdG-339228 (SEECAT) and the Spanish SEIDI, grant FIS2013-41237-R. David Atchison: Australian Research Council Discovery Grants DP110102018 and DP140101480. Karen Hampson: UK College of Optometrists; EPSRC (Engineering and Physical Sciences Research Council), Grants EP/ D036550/1and EP/G015473/1. Linda Lundstrom: Swedish Agency for Innovation Systems (VINNMER 2008–00992) and Swedish Research Council (621-2011-4094). Geungyoung Yoon: NIH/NEI, NYSTAR. Stephen Burns and Ann Elsner NIH Grants EY007624, EY026105, EY024315 and EY004395. P30EY019008 and Foundation Fighting Blindness., Joseph Carroll: NIH R01EY017607, Foundation Fighting Blindness, and Research to Prevent Blindness. Stacey S. Choi and Nathan Doble: support by NIH EY020901 and Department of Defense (DoD) Telemedicine and Advanced Technology Research Center (TATRC) grant W81XWH-10-1-0738. Alfredo Dubra: the Burroughs Wellcome Fund, Research to Prevent Blindness, Glaucoma Research Foundation and National Eye Institute. Ravi Jonnal NEI K99 EY 026068. Donald Miller NEI R01-EY018339 and P30-EY019008. Michel Paques: Institut National de la Santé et de la Recherche Médicale (Contrat d’Interface 2011) the Agence Nationale de la Recherche (ANR-09-TECS-009, ANR-12-TECS-0015- 03 and LabEx LifeSenses ANR-10-LABX-65). Hannah Smithson and Laura K. Young: the John Fell Fund (University of Oxford), Fight for Sight, and the Wellcome Trust Institutional Strategic Support Fund. Yuhua Zhang: NIH Grants EY021903, EY024378, P30 EY003039) and NSF IIA-1539034., Melanie Campbell: Canadian Institutes of Health Research and Natural Sciences and Engineering Research Council of Canada Collaborative Health Research Program. Jennifer Hunter: NIH R44 AG043645, R01 EY022371, R01 EY004367, P30 EY001319, and BRP-EY014375. Also supported by an unrestricted grant to the University of Rochester Department of Ophthalmology from Research to Prevent Blindness, New York, New York. Andrew Metha: Supported by an Australia Research Council (ARC) Discovery Project Grant (DP0984649), an ARC Discovery Early Career Researcher Award (DE120101931), an A.E. Rowden White Foundation benevolent bequest, and the University of Melbourne Interdis- ciplinary Seed Fund. Grazyna Palczewska: NIH NEI R44 AG043645, European Private Foundation. Jesse Schallek: NIH Grants EY023496-01, EY014375, EY001319, The Schmitt Program on Integrative Brain Research, the Research to Prevent Blindness Stein Innovation award, Research to Prevent Blindness Career Development award (Schallek), an unrestricted grant to the University of Rochester Department of Ophthalmology from Research to Prevent Blindness, New York, New York, and Canon Inc. Lawrence Sincich: National Eye Institute, Eyesight Foundation of Alabama.William H. Merigan: NIH R44 AG043645, R01 EY021166, and P30 EY001319. Also by an unrestricted grant to the University of Rochester Department of Ophthalmology from Research to Prevent Blindness, New York, New York., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Wearable See-thru Binocular Simulator of Multifocal and Monovision Presbyopic Corrections

  • Marcos, Susana
  • Marcos, Susana
  • Viñas, María
  • Radhakrishnan, Aiswaryah
  • Benedi, Clara
  • Aissati, Sara
  • Gambra, Enrique
  • Pascual, Daniel
  • Akondi, Vyas
  • Alonso-Sanz, J. R.
  • Méndez-González, Juan Luis
  • Barcala, Xoana
  • Dorronsoro, Carlos
Presentación con 32 diapositivas. -- San Jose, California, United States of America, Feb 24 - 25, 2017, Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Estimation of intraocular lens position from full crystalline lens geometry: Towards a new generation of intraocular lens power calculation formulas

  • Martínez-Enríquez, Eduardo
  • Pérez Merino, Pablo
  • Durán-Poveda, Sonia
  • Jiménez-Alfaro, Ignacio
  • Marcos, Susana
11 pags., 5 figs., 4 tabs. -- Open Access funded by Creative Commons Atribution Licence 4.0, In a cataract surgery, the opacified crystalline lens is replaced by an artificial intraocular lens (IOL). To optimize the visual quality after surgery, the intraocular lens to be implanted must be selected preoperatively for every individual patient. Different generations of formulas have been proposed for selecting the intraocular lens dioptric power as a function of its estimated postoperative position. However, very few formulas include crystalline lens information, in most cases only one-dimensional. The present study proposes a new formula to preoperatively estimate the postoperative IOL position (ELP) based on information of the 3-dimensional full shape of the crystalline lens, obtained from quantitative eye anterior segment optical coherence tomography imaging. Real patients were measured before and after cataract surgery (IOL implantation). The IOL position and the postoperative refraction estimation errors were calculated by subtracting the preoperative estimations from the actual values measured after surgery. The proposed ELP formula produced lower estimation errors for both parameters-ELP and refraction-than the predictions obtained with standard state-of-the-art methods, and opens new avenues to the development of new generation IOL power calculation formulas that improve refractive and visual outcomes., The research leading to these results has received funding from the European Research Council under the European Union’s Seventh Framework Programme (FP7/2007-2013)/ERC Grant Agreement ERC-2011-AdG- 294099. This study has been also supported by Spanish government grants FIS2011-25637 and FIS2014-56643-R to S. Marcos. The funding organizations had no role in the design or conduct of this research., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Quantization of collagen organization in the stroma with a new order coefficient

  • Germann, James
  • Martínez-Enríquez, Eduardo
  • Marcos, Susana
17 pags., 10 figs., tab. -- OCIS codes: (180.4315) Nonlinear microscopy; (170.6900) Three-dimensional microscopy; (170.6935) Tissue characterization; (170.3880) Medical and biological imaging; (100.2960) Image analysis., Many optical and biomechanical properties of the cornea, specifically the transparency of the stroma and its stiffness, can be traced to the degree of order and direction of the constituent collagen fibers. To measure the degree of order inside the cornea, a new metric, the order coefficient, was introduced to quantify the organization of the collagen fibers from images of the stroma produced with a custom-developed second harmonic generation microscope. The order coefficient method gave a quantitative assessment of the differences in stromal collagen arrangement across the cornea depths and between untreated stroma and cross-linked stroma., European Research Council Advanced Grant (2011-AdG-294099) and Spanish Government (FIS2014-56643)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Experimental validations of a tunable-lens-based visual demonstrator of multifocal corrections

  • Akondi, Vyas
  • Sawides, L.
  • Marrakchi, Y.
  • Gambra, Enrique
  • Marcos, Susana
  • Dorronsoro, Carlos
16 pags., 8 figs. 2 tabs., The Simultaneous Vision simulator (SimVis) is a visual demonstrator of multifocal lens designs for prospective intraocular lens replacement surgery patients and contact lens wearers. This programmable device employs a fast tunable lens and works on the principle of temporal multiplexing. The SimVis input signal is tailored to mimic the optical quality of the multifocal lens using the theoretical SimVis temporal profile, which is evaluated from the through-focus Visual Strehl ratio metric of the multifocal lens. In this paper, for the first time, focimeter-verified on-bench validations of multifocal simulations using SimVis are presented. Two steps are identified as being critical to accurate SimVis simulations. Firstly, a new iterative approach is presented that improves the accuracy of the theoretical SimVis temporal profile for three different multifocal intraocular lens designs – diffractive trifocal, refractive segmented bifocal, and refractive extended depth of focus, while retaining a low sampling. Secondly, a fast focimeter is used to measure the step response of the tunable lens, and the input signal is corrected to include the effects of the transient behavior of the tunable lens. It was found that the root-mean-square of the difference between the estimated through-focus Visual Strehl ratio of the multifocal lens and SimVis is not greater than 0.02 for all the tested multifocal designs., Consejería de Educación, Juventud y Deporte of Comunidad de Madrid and the People Programme (Marie Curie Actions) of the European Union’s Seventh Framework Programme (FP7/2007-2013) (n 291820 to VA); EU H2020 SME Innovation Associate (GA-739882); Spanish Government Torres-Quevedo Program (PTQ-15-07432); EIT Health (2017 HS PoC Spain 05); Ministerio de Economía y Competitividad (DTS16-00127); ERC (ERC-2011-AdC 294099); Spanish Government (FIS2014-56643-R, FIS2017-84753-R)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Design and ex situ performance of a shape-changing accommodating intraocular lens

  • Hoz, A. de la
  • Germann, James
  • Martínez-Enríquez, Eduardo
  • Pascual, Daniel
  • Bekesi, Nandor
  • Alejandre, Nicolás
  • Dorronsoro, Carlos
  • Marcos, Susana
OSA Open Access Publishing Agreement, Presbyopia, the age-related loss of the crystalline lens’s ability to dynamically focus, occurs primarily because of stiffening of lens material, making the ciliary muscle forces insufficient to reshape the lens. Despite its prevalence, there is no satisfactory solution to presbyopia. Here we present a novel accommodating intraocular lens (AIOL) able to reshape upon equatorial forces in compliance with the eye’s accommodating mechanism. The concept and design parameters are demonstrated through finite element model simulations and measurements in a manufactured AIOL prototype, using custom quantitative 3D OCT (geometrical changes) and laser ray tracing (power changes), with forces radially applied using a custom eight-arm mechanical stretcher. There was an excellent agreement between simulations and measurements (1% for the focal length and 11.4% for geometrical parameters, on average) for radial load up to 0.6 N. The developed design is expected to achieve ∼2.5D of effective power change with a polymer material with 0.10–0.25 MPa Young’s modulus and n = 1.43 − 1.46., H2020 European Research Council (ERC) (ERC2011-AdG-294099); Ministerio de Economía y Competitividad (MINECO) (BES-2015-072197, FIS2014-56643-R, FIS2017-84753-R)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Visual simulators replicate vision with multifocal lenses

  • Viñas, María
  • Benedi, Clara
  • Aissati, Sara
  • Pascual, Daniel
  • Akondi, Vyas
  • Dorronsoro, Carlos
  • Marcos, Susana
11 pags., 7 figs. -- Open Access funded by Creative Commons Atribution Licence 4.0, Adaptive optics (AO) visual simulators based on deformable mirrors, spatial light modulators or optotunable lenses are increasingly used to simulate vision through different multifocal lens designs. However, the correspondence of this simulation with that obtained through real intraocular lenses (IOLs) tested on the same eyes has not been, to our knowledge, demonstrated. We compare through-focus (TF) optical and visual quality produced by real multifocal IOLs (M-IOLs) -bifocal refractive and trifocal diffractive- projected on the subiect’s eye with those same designs simulated with a spatial light modulator (SLM) or an optotunable lens working in temporal multiplexing mode (SimVis technology). Measurements were performed on 7 cyclopleged subjects using a custom-made multichannel 3-active-optical-elements polychromatic AO Visual Simulator in monochromatic light. The same system was used to demonstrate performance of the real IOLs, SLM and SimVis technology simulations on bench using double-pass imaging on an artificial eye. Results show a general good correspondence between the TF performance with the real and simulated M-IOLs, both optically (on bench) and visually (measured visual acuity in patients). We demonstrate that visual simulations in an AO environment capture to a large extent the individual optical and visual performance obtained with real M-IOLs, both in absolute values and in the shape of through-focus curves., Tis research has received funding from the European Research Council under the European Union’s Seventh Framework Program (FP/2007–2013)/ERC Grant Agreement. [ERC-2011-AdC 294099]; the H2020 COFUND Marie Curie 291820 program; ERCPoC SimVis project. Tis study was also supported by Spanish Government grant FIS2014-56643-R to S.M., FIS2017-84753-R to S.M. and C.D., and DTS16-00127 to C.D., and Spanish Government FPU Predoctoral Fellowship (FPU16/01944) to S.A. Authors thank Laura Barrios from the Scientifc Calculus Center of the Spanish National Research Council (CSIC) for help with the statistical analysis.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Vision with different presbyopia corrections simulated with a portable binocular visual simulator

  • Radhakrishnan, Aiswaryah
  • Pascual, Daniel
  • Marcos, Susana
  • Dorronsoro, Carlos
13 pags., 5 figs.-- Open Access funded by Creative Commons Atribution Licence 4.0, Presbyopes can choose today among different corrections to provide them with functional vision at far and near, and the outcomes and patient satisfaction depend on the selection. In this study, we present a binocular and portable vision simulator, based on temporal multiplexing of two synchronized tunable lenses allowing see-through and programmable visual simulations of presbyopic corrections. Seventeen binocular corrections were tested: 3 Monofocal (Far, Intermediate, Near), 4 Simultaneous Vision (bifocal, trifocal), 2 Monovision (far and near in either eye) and 8 Modified Monovision corrections (Simultaneous vision in one eye, Monofocal in the other eye). Perceived visual quality was assessed through the simulated corrections in 8 cyclopleged subjects who viewed a composite realistic visual scene with high contrast letters and a landscape at far (4 m) and a high contrast text at intermediate (66 cm) and near (33 cm) distances. Perceptual scores were obtained on a scale of 0 to 5 (low to high perceived quality). Perceptual preference was assessed by judging 36 random image pairs (6 repetitions) viewed through 9 binocular presbyopic corrections using two-interval forced choice procedures. The average score, across far and near distances, was the highest for Monovision (4.4±0.3), followed by Modified Monovision (3.4±0.1), Simultaneous Vision (3.0±0.1) and Monofocal corrections (2.9±0.2). However, the mean difference between far and near was lower for Simultaneous Vision and Monovision (0.4±0.1 PS) than Modified Monovision (1.8±0.7) or monofocal corrections (3.3±1.5). A strong significant correlation was found between the perceptual scores and the percentages of energy in focus, for each correction and distance (R = 0.64, p<0.0001). Multivariate ANOVA revealed significant influence of observation distances (p<10–9) and patients (p = 0.01) on Perceptual Score. In conclusion, we have developed a binocular portable vision simulator that can simulate rapidly and non-invasively different combinations of presbyopic corrections. This tool has applications in systematic clinical evaluation of presbyopia corrections., This work was supported by: European Research Council under the European Union’s Seventh Framework Programme FP7/2007-2013, ERC Grant Agreement nº ERC-AdG-294099, Spanish Government grant FIS2014-56643-R to SM; ISCIII DTS16/00127 to CD; Spanish Government grant FIS2017-84753-R to CD and SM; and by 7th Framework Programme of the European Community through the Marie Curie
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Tunable lenses: Dynamic characterization and fine-tuned control for high-speed applications

  • Dorronsoro, Carlos
  • Barcala, Xoana
  • Gambra, Enrique
  • Akondi, Vyas
  • Sawides, L.
  • Marrakchi, Y.
  • Rodríguez-López, Víctor
  • Benedi, Clara
  • Viñas, María
  • Lage, Eduardo
  • Marcos, Susana
16 pags., 9 figs., 1 tab., Tunable lenses are becoming ubiquitous, in applications including microscopy, optical coherence tomography, computer vision, quality control, and presbyopic corrections. Many applications require an accurate control of the optical power of the lens in response to a time-dependent input waveform. We present a fast focimeter (3.8 KHz) to characterize the dynamic response of tunable lenses, which was demonstrated on different lens models. We found that the temporal response is repetitive and linear, which allowed the development of a robust compensation strategy based on the optimization of the input wave, using a linear time-invariant model. To our knowledge, this work presents the first procedure for a direct characterization of the transient response of tunable lenses and for compensation of their temporal distortions, and broadens the potential of tunable lenses also in high-speed applications., VA and EL acknowledge financial support from Comunidad de Madrid and Marie Curie Action of the European Union FP7/2007-2013 COFUND 291820; XB from Comunidad de Madrid Doctorado Industrial IND2017/BMD-7670; EL from Spanish Government Ramon y Cajal Program RyC-2016-21125; EG from Spanish Government Torres-Quevedo Program PTQ-15-07432; LS from EU H2020 SME Innovation Associate GA-739882; EG from EIT Health; SM from ERC Grant Agreement ERC-2011-AdC 294099 and Spanish Government Grants FIS2014-56643-R; SM and CD from Spanish Government Grant FIS2017-84753-R; and CD from DTS16-00127.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Perceptual impact of astigmatism induction in presbyopes

  • Benedi, Clara
  • Velasco Ocaña, Miriam
  • Dorronsoro, Carlos
  • Pascual, Daniel
  • Hernández, M.
  • Marín, Gildas
  • Marcos, Susana
9 pags., 8 figs., 2 tabs., We investigated the effect of induced astigmatism on subjective best focus and on visual acuity in 28 subjects of different ages (pre-presbyopic and presbyopic) and with different refractive profiles (emmetropes and astigmats). Measurements were performed using a custom-developed Adaptive Optics system, which allowed correction of high order aberrations and induction of astigmatism (0.5, 1, 1.5 and 2.0 D; axis: 180°, 45° and 22.5°). Upon induction of astigmatism, best focus shifted towards negative values in pre-presbyopic emmetropic eyes (by −0.14 D for 0.5 D and by −0.33 D for 2.0 D), while it shifted towards positive values in presbyopes, both in emmetropic presbyopes (by +0.04 D for 0.50 D and by +0.16 D for 2.0 D) and in astigmatic presbyopes (by +0.23 D for 0.50 D and by +0.40 D for 2.0 D). Also, visual acuity was most sensitive to astigmatism induction in pre-presbyopic emmetropes and least sensitive in presbyopes, particularly when high order aberrations were corrected: visual acuity ratio with/without astigmatism was: 0.74/0.85/0.98 (for astigmatism induced at 180°) and 0.68/0.73/0.86 at 45°, for pre-presbyopic emmetropes/presbyopic emmetropes/presbyopic astigmats. These findings may be connected to long term exposure to astigmatism in astigmats and corrected presbyopes., The authors acknowledge funding from the European Research Council ERC2011-294099 and Spanish Government Grants FIS201784753-R,and a collaborative research grant with Essilor International.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Morphological changes of human crystalline lens in myopia

  • Muralidharan, Geethika
  • Martínez-Enríquez, Eduardo
  • Birkenfeld, Judith S.
  • Velasco Ocaña, Miriam
  • Pérez Merino, Pablo
  • Marcos, Susana
12 pags., 3 figs., 2 tabs., Ocular biometric parameters, including full shape crystalline lens, were assessed in myopes and emmetropes using 3-D optical coherence tomography. The anterior chamber depth, the radius of the curvature of the anterior cornea, anterior lens, and posterior lens, lens thickness, lens equatorial diameter, surface area, equatorial position, volume, and power, were evaluated as functions of refractive errors and axial lengths while controlling for age effects. The crystalline lens appears to change with myopia consistent with lens thinning, equatorial, and capsular stretching while keeping constant volume. Axial elongation appears counteracted by a crystalline lens power reduction, while corneal power remains unaffected., European Research Council (ERC-2011-AdG- 294099, H-2020-MSCA-COFUND-2015 Ref. 713694, H-2020-MSCA-ITN-2015-ETN-MyFUN No: 675137); Ministerio de Ciencia, Innovación y Universidades (FIS 2017-84753 R MYOPT).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Interaction of monochromatic and chromatic aberrations in pseudophakic patients

  • Marcos, Susana
  • Romero, Mercedes
  • Benedi, Clara
  • González-Ramos, Ana
  • Viñas, María
  • Alejandre, Nicolás
  • Jiménez-Alfaro, Ignacio
10 pags., 7 figs., 1 tab., PURPOSE: To measure monochromatic aberrations at various wavelengths in eyes implanted with the Clareon monofocal aspheric intraocular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX). The authors estimated longitudinal chromatic aberration (LCA), modulation transfer functions (MTFs), and the impact of interactions between chromatic and monochromatic aberrations on retinal image quality. METHODS: Ten patients (age: 68.4 ± 3.21 years) were measured in two experiments: (1) Hartmann-Shack wave aberrations at five visible wavelengths (480 to 700 nm) and (2) best subjective focus at each wavelength. Objective and psychophysical LCAs were obtained from the Zernike defocus and psychophysical best focus, respectively. MTFs were calculated for the closest wavelengths to the peak sensitivity of the three cone classes (S [480 nm], M [555 nm], and L [564 nm]) using the measured aberrations and chromatic difference of focus. The degradation produced by LCA was estimated as the visual Strehl ratio for green divided by the visual Strehl ratio for blue and red. RESULTS: The root mean square for higher order aberrations (HOAs) ranged from 0.0622 to 0.2084 µm (700 nm, 4.3-mm pupil). Monochromatic visual Strehl ratio was above 0.35 in all patients. LCA was 1.23 ± 0.05 diopters (D) (psychophysical) and 0.90 ± 0.11 D (objective). Visual Strehl ratio decreased by a factor ranging from 1.38 to 3.82 on chromatic defocus from green to blue. There was a significant correlation between native visual Strehl ratio and the degradation produced by LCA (ie, visual Strehl/visual Strehl). CONCLUSIONS: The Clareon IOL compensates for spherical aberration, with postoperative wave aberrations dominated by astigmatism and other HOAs, being highly subject-dependent. The impact of LCA in blue is largely dependent on the magnitude of monochromatic aberrations., Supported by ERC Grant Agreement (ERC-2011-AdG-294099) and Spanish Government grant FIS 2017-84753 (SM); Spanish Ministry of Science Aids for recruiting Technical Support Personnel PTA2017-13787-I (MR), and Madrid Regional Government Spanish Ministry of Science Aids for recruiting Technical Support Personnel PTA2017-13787-I (AG-R). The study was partially funded by a Research Collaborative Agreement with Alcon Research Labs.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

VioBio lab adaptive optics: technology and applications by women vision scientists

  • Marcos, Susana
  • Benedi, Clara
  • Aissati, Sara
  • González-Ramos, Ana
  • Lago, Carmen M.
  • Radhakrishnan, Aiswaryah
  • Romero, Mercedes
  • Vedhakrishnan, Shrilekha
  • Sawides, L.
  • Viñas, María
13 pags., 9 figs., Purpose: Adaptive Optics allows measurement and manipulation of the optical aberrations of the eye. We review two Adaptive Optics set-ups implemented at the Visual Optics and Biophotonics Laboratory, and present examples of their use in better understanding of the role of optical aberrations on visual perception, in normal and treated eyes. Recent findings: Two systems (AOI and AOII) are described that measure ocular aberrations with a Hartmann-Shack wavefront sensor, which operates in closed-loop with an electromagnetic deformable mirror, and visual stimuli are projected in a visual display for psychophysical measurements. AOI operates in infrared radiation (IR) light. AOII is provided with a supercontiniuum laser source (IR and visible wavelengths), additional elements for simulation (spatial light modulator, temporal multiplexing with optotunable lenses, phase plates, cuvette for intraocular lenses-IOLs), and a double-pass retinal camera. We review several studies undertaken with these AO systems, including the evaluation of the visual benefits of AO correction, vision with simulated multifocal IOLs (MIOLs), optical aberrations in pseudophakic eyes, chromatic aberrations and their visual impact, and neural adaptation to ocular aberrations. Summary: Monochromatic and chromatic aberrations have been measured in normal and treated eyes. AO systems have allowed understanding the visual benefit of correcting aberrations in normal eyes and the adaptation of the visual system to the eye's native aberrations. Ocular corrections such as intraocular and contact lenses modify the wave aberrations. AO systems allow simulating vision with these corrections before they are implanted/fitted in the eye, or even before they are manufactured, revealing great potential for industry and the clinical practice. This review paper is part of a special issue of Ophthalmic & Physiological Optics on women in visual optics, and is co-authored by all women scientists of the research team., This study has been supported by European Research Council Grant Agreement ERC‐2011‐AdG‐294099 and EUROHORCS EURYI‐05‐102‐ES to SM; Spanish Government grants FIS2005‐04382, FIS2008‐02065, FIS2011‐25637, FIS2014‐240920, FIS2017‐84753 (SM); Spanish Government Human Resource Programs PTA2017‐13787‐I (MR) and FPU Fellowships (MV, SA, LS), Marie Curie Initial Training Networks PITN‐GA‐2010‐264605 Opal (AR) and H‐2020‐MSCA‐ITN‐2015‐ETN‐MyFUN 675137; Comunidad Autónoma de Madrid Fundacion Madri+d Industrial Doctorate Program (CL) and Technical Support Personnel (AMG). Collaborative agreements with PhysIOL (Liège, Belgium), Alcon Research Labs (Fort Worth, Texas, USA) and Essilor International (France) have partially funded some of the results presented here.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Optical and visual quality with physical and visually simulated presbyopic multifocal contact lenses

  • Viñas, María
  • Aissati, Sara
  • González-Ramos, Ana
  • Romero, Mercedes
  • Sawides, L.
  • Akondi, Vyas
  • Gambra, Enrique
  • Dorronsoro, Carlos
  • Karkkainen, T.
  • Nankivil, D.
  • Marcos, Susana
16 pags. 6 figs., 1 tab., Purpose: As multifocal contact lenses (MCLs) expand as a solution for presbyopia correction, a better understanding of their optical and visual performance becomes essential. Also, providing subjects with the experience of multifocal vision before contact lens fitting becomes critical, both to systematically test different multifocal designs and to optimize selection in the clinic. In this study, we evaluated the ability of a simultaneous vision visual simulator (SimVis) to represent MCLs. Methods: Through focus (TF) optical and visual quality with a center-near aspheric MCL (low, medium and high near adds) were measured using a multichannel polychromatic Adaptive Optics visual simulator equipped with double-pass, SimVis (temporal multi-plexing), and psychophysical channels to allow measurements on-bench and in vivo. On bench TF optical quality of SimVis-simulated MCLs was obtained from double-pass (DP) images and images of an E-stimulus using artificial eyes. Ten presbyopic subjects were fitted with the MCL. Visual acuity (VA) and DP retinal images were measured TF in a 4.00 D range with the MCL on eye, and through SimVis simulations of the same MCLs on the same subjects. Results: TF optical (on bench and in vivo) and visual (in vivo) quality measurements captured the expected broadening of the curves with increasing add. Root mean square difference between real and SimVis-simulated lens was 0.031/0.025 (low add), 0.025/0.015 (medium add), 0.019/0.011 (high add), for TF DP and TF LogMAR VA, respectively. A shape similarity metric shows high statistical values (lag κ = 0), rho = 0.811/0.895 (low add), 0.792/0.944 (medium add), and 0.861/0.915 (high add) for TF DP/LogMAR VA, respectively. Conclusions: MCLs theoretically and effectively expand the depth of focus. A novel simulator, SimVis, captured the through-focus optical and visual performance of the MCL in most of the subjects. Visual simulators allow subjects to experience vision with multifocal lenses prior to testing them on-eye. Translational Relevance: Simultaneous visual simulators allow subjects to experience multifocal vision non-invasively. We demonstrated equivalency between real multifocal contact lenses and SimVis-simulated lenses. The results suggest that SimVis is a suitable technique to aid selection of presbyopic corrections in the contactology practice., Supported by the European Research Council (ERC-2011-AdC 294099) to SM; Spanish Government (FIS2017-84753R) to SM, and pre-doctoral fellowship (FPU16/01944) to SA; Collaborative agreement with Johnson & Johnson Vision, Inc., Research & Development, Jacksonville, FL, USA.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Testing the effect of ocular aberrations in the perceived transverse chromatic aberration

  • Aissati, Sara
  • Viñas, María
  • Benedi, Clara
  • Dorronsoro, Carlos
  • Marcos, Susana
17 pags., 9 figs., We have measured the ocular transverse chromatic aberration (TCA) in 11 subjects using 2D-two-color Vernier alignment, for two pupil diameters, in a polychromatic adaptive optics (AO) system. TCA measurements were performed for two pupil diameters: for a small pupil (2-mm), referred to as 'optical TCA' (oTCA), and for a large pupil (6-mm), referred to 'perceived TCA' (pTCA). Also, the TCA was measured through both natural aberrations (HOAs) and AO-corrected aberrations. Computer simulations of pTCA incorporated longitudinal chromatic aberration (LCA), the patient's HOAs measured with Hartmann-Shack, and the Stiles-Crawford effect (SCE), measured objectively by laser ray tracing. The oTCA and the simulated pTCA (no aberrations) were shifted nasally 1.20 arcmin and 1.40 arcmin respectively. The experimental pTCA (-0.27 arcmin horizontally and -0.62 vertically) was well predicted (81%) by simulations when both the individual HOAs and SCE were considered. Both HOAs and SCE interact with oTCA, reducing it in magnitude and changing its orientation. The results indicate that estimations of polychromatic image quality should incorporate patient's specific data of HOAs, LCA, TCA & SCE., European Research Council (ERC-2011-AdC 294099); H2020 Marie Skłodowska-Curie Actions (H2020 COFUND Marie Curie 291820 program); Spanish Government (FIS2014-56643R, FIS2017-84753R, FPU16/01944, ISCIII DTS16/00127).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Vision with Multifocal contact lenses in Myopes and Presbyopes

  • Vedhakrishnan, Shrilekha
  • Viñas, María
  • Casado-Moreno, Pilar
  • Benedi, Clara
  • Dorronsoro, Carlos
  • Marcos, Susana
ARVO Annual Meeting Abstract , June 2020, Spanish government grant FIS2017-84753-R, European Project PRESBYOPIA ERC-2011-AdG Ref. 294099, European Project MyFUN H2020MSCA-ITN-2015 Ref. 675137, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Vision is protected against blue defocus

  • Benedi, Clara
  • Viñas, María
  • Dorronsoro, Carlos
  • Marcos, Susana
9 pags., 4 figs., Due to chromatic aberration, blue images are defocused when the eye is focused to the middle of the visible spectrum, yet we normally are not aware of chromatic blur. The eye sufers from monochromatic aberrations which degrade the optical quality of all images projected on the retina. The combination of monochromatic and chromatic aberrations is not additive and these aberrations may interact to improve image quality. Using Adaptive Optics, we investigated the optical and visual efects of correcting monochromatic aberrations when viewing polychromatic grayscale, green, and blue images. Correcting the eye’s monochromatic aberrations improved optical quality of the focused green images and degraded the optical quality of defocused blue images, particularly in eyes with higher amounts of monochromatic aberrations. Perceptual judgments of image quality tracked the optical fndings, but the perceptual impact of the monochromatic aberrations correction was smaller than the optical predictions. The visual system appears to be adapted to the blur produced by the native monochromatic aberrations, and possibly to defocus in blue., We acknowledge funding by the European Research Council (ERC Grant Agreement ERC-2011-AdG-294099), FIS2017-84753-R (SM), Alcon Research Institute (SM & EP), and NIH Grant R01EY023385 (EP).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

In vivo chromatic aberration in eyes implanted with intraocular lenses

  • Pérez Merino, Pablo
  • Dorronsoro, Carlos
  • Llorente, Lourdes
  • Durán, Sonia
  • Jiménez-Alfaro, Ignacio
  • Marcos, Susana
8 pags., 4 figs., 2 tabs. -- Presented at the XXX Congress of the European Society of Cataract & Refractive Surgeons, Milan, Italy, September 2012., PURPOSE. To measure in vivo and objectively the monochromatic aberrations at different wavelengths, and the chromatic difference of focus between green and infrared wavelengths in eyes implanted with two models of intraocular lenses (IOL). METHODS. Eighteen eyes participated in this study: nine implanted with Tecnis ZB99 1-Piece acrylic IOL and nine implanted with AcrySof SN60WF IOL. A custom-developed laser ray tracing (LRT) aberrometer was used to measure the optical aberrations, at 532 nm and 785 nm wavelengths. The monochromatic wave aberrations were described using a fifth-order Zernike polynomial expansion. The chromatic difference of focus was estimated as the difference between the equivalent spherical errors corresponding to each wavelength. RESULTS. Wave aberration measurements were highly reproducible. Except for the defocus term, no significant differences in high order aberrations (HOA) were found between wavelengths. The average chromatic difference of focus was 0.46 6 0.15 diopters (D) in the Tecnis group, and 0.75 6 0.12 D in the AcrySof group, and the difference was statistically significant (P < 0.05). Chromatic difference of focus in the AcrySof group was not statistically significantly different from the Longitudinal chromatic aberration (LCA) previously reported in a phakic population (0.78 6 0.16 D). The impact of LCA on retinal image quality (measured in terms of Strehl ratio) was drastically reduced when considering HOA and astigmatism in comparison with a diffraction-limited eye, yielding the differences in retinal image quality between Tecnis and AcrySof IOLs not significant. CONCLUSIONS. LRT aberrometry at different wavelengths is a reproducible technique to evaluate the chromatic difference of focus objectively in eyes implanted with IOLs. Replacement of the crystalline lens by the IOL did not increase chromatic difference of focus above that of phakic eyes in any of the groups. The AcrySof group showed chromatic difference of focus values very similar to physiological values in young eyes. © 2013 The Association for Research in Vision and Ophthalmology, Inc., Supported by Ministerio de Educacion y Ciencia, Spain (Grants ´ FIS2008-02065, FIS2011-25637); EURHORCs-ESF EURYI-05-102-ES and European Research Council (ERC-2011-AdG-294099; SM); and by a Collaborative Agreement with Alcon Research Labs, Fort Worth, Texas.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Contributing factors to corneal deformation in air puff measurements

  • Kling, Sabine
  • Marcos, Susana
8 pags., 5 figs., 2 tabs., PURPOSE. Air puff systems have been presented recently to measure corneal biomechanical properties in vivo. In our study we tested the influence of several factors on corneal deformation to an air puff: IOP, corneal rigidity, dehydration, presence of sclera, and in vivo versus in vitro conditions. METHODS. We used 14 freshly enucleated porcine eyes and five human donor eyes for in vitro experiments; nine human eyes were used for in vivo experiments. Corneal deformation was studied as a function of: IOP ranging from 15 to 45 mm Hg (in vitro); dehydration after riboflavin-dextran instillation (in vitro); corneal rigidity after standard ultraviolet (UV) corneal crosslinking (CXL, in vitro); boundary conditions, that is effect of the presence of the sclera (comparing corneal buttons and whole globes in vitro in pigs); and effect of ocular muscles (comparing human whole globes in vitro and in vivo). The temporal corneal deformation was characterized by the apex indentation across time, the maximal indentation depth, and the temporal symmetry (comparing inward versus outward deformation). The spatial corneal profile was characterized by the peak distance at maximal deformation. RESULTS. Temporal and spatial deformation profiles were very sensitive to the IOP (P < 0.001). The sclera slightly affected the temporal symmetry, while the ocular muscles drastically changed the amount of corneal recovery. CXL produced a significant (P=0.001) reduction of the cornea indentation (by a factor of 1.41), and a change in the temporal symmetry of the corneal deformation profile (by a factor of 1.65), indicating a change in the viscoelastic properties with treatment. CONCLUSIONS. Corneal deformation following an air puff allows the measurement of dynamic properties, which are essential for the characterization of corneal biomechanics. © 2013 The Association for Research in Vision and Ophthalmology, Inc., Supported by Spanish Government FIS2011-25637 (SM) and FPIBES-2009-024560 Predoctoral Fellowship (SK). The research leading to these results has received funding from the European Research Council under the European Union’s Seventh Framework Programme (FP7/2007–2013)/ERC Grant Agreement number 294099. The authors alone are responsible for the content and writing of the paper.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Multifocal acceptance score to evaluate vision: MAS‑2EV

  • Barcala, Xoana
  • Viñas, María
  • Romero, Mercedes
  • Gambra, Enrique
  • Méndez‑González, Juan Miguel
  • Marcos, Susana
  • Dorronsoro, Carlos
15 pags., 10 figs. 3 tabs., We present a new metric (Multifocal Acceptance Score, MAS-2EV) to evaluate vision with presbyopic corrections. The MAS-2EV is based on a set of images representing natural visual scenes at day and night conditions projected in far and near displays, and a near stereo target. Subjects view and score the images through diferent binocular corrections (monofocal corrections at far; bifocal corrections; monovision and modifed monovision) administered with soft contact lenses (in cyclopleged young subjects) or with a binocular simultaneous vision simulator (in presbyopic and cyclopleged young subjects). MAS-2EV scores are visually represented in the form of polygons, and quantifed using diferent metrics: overall visual quality, visual degradation at far, visual beneft at near, near stereo beneft, visual imbalance near-far, overall visual imbalance and a combined overall performance metric. We have found that the MAS-2EV has sufcient repeatability and sensitivity to allow diferentiation across corrections with only two repetitions, and the duration of the psychophysical task (3 min for subject/condition/correction) makes it useable in the clinic. We found that in most subjects binocular bifocal corrections produce the lowest visual imbalance, and the highest near stereo beneft. 46.67% of the subjects ranked binocular bifocal corrections frst, and 46.67% of the subjects ranked monovision frst. MAS-2EV, particularly in combination with visual simulators, can be applied to select prospective presbyopic corrections in patients prior to contact lens ftting or intraocular lens implantation., European Research Council (ERC-2011-AdC 294099 to SM); Spanish Government (FIS2017-84753R to SM, ISCIII DTS16/00127 to CD, DI-15-07753 to JLM, PTQ-15-07432 to EG, PTA2017-13787-I to MR), and Madrid Regional Government (IND2017/BMD-7670 to XB)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Rose bengal and green light versus riboflavin–UVA cross-linking: Corneal wound repair response

  • Lorenzo-Martín, Elvira
  • Gallego-Muñoz, Patricia
  • Ibares-Frías, L.
  • Marcos, Susana
  • Pérez Merino, Pablo
  • Fernández, Itziar
  • Kochevar, Irene E.
  • Martínez-García, María Carmen
10 pags., 10 figs., PURPOSE. To study corneal wound healing after two cross-linking techniques using either rose bengal and green light (RGX) or the conventional treatment using riboflavin and UVA radiation (UVX). METHODS. Corneas of New Zealand rabbits were monolaterally treated with UVX (21 eyes) or RGX (25 eyes). Treatments involved corneal de-epithelialization (8-mm diameter), soaking with photosensitizer (0.1% riboflavin in 20% dextran for 30 minutes for UVX; 0.1% rose bengal for 2 minutes for RGX), and light irradiation (370 nm, 3 mW/cm, 30 minutes for UVX; 532 nm, 0.25 W/cm, 7 minutes for RGX). Contralateral eyes were used as controls. Clinical follow-up included fluorescein staining, haze measurement, and pachymetry. Healing events analyzed after euthanasia at 2, 30, and 60 days included cell death (TUNEL assay), cell proliferation (BrdU [bromodeoxyuridine] immunofluorescence), and differentiation to myofibroblasts (α-SMA [alpha smooth muscle actin] immunohistochemistry). RESULTS. Re-epithelialization and pachymetries were similar after RGX and UVX. The haze from day 1 to 15 was greater after UVX. Cell death was deeper after UVX, being localized in the anterior and middle stroma, and was superficial (anterior third) after RGX. Cell proliferation appeared after 2 days and was localized in the middle and posterior stroma in the UVX group but was superficial in the RGX group. After 60 days the number of stromal cells had not returned to the control number in either group. CONCLUSIONS. The deeper and longer-lasting cell damage caused by UVX compared to RGX may underlie the slower cell repopulation after UVX and other differences in healing. Shallower damage and a shorter treatment time suggest that RGX may be appropriate for stiffening thin corneas., Supported by European Research Council ERC-2011-AdC-294099 (SM), Spanish Government Grants FIS2011-25637-R (SM), FIS2014- 56643-R, and FIS2017-84753-R (SM)
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Intraocular photobonding to enable accommodating intraocular lens function

  • Alejandre, Nicolás
  • Gutierrez-Contreras, R.
  • Dorronsoro, Carlos
  • Marcos, Susana
9 pags., 4 figs., Purpose: Accommodating intraocular lenses (A-IOLs) require capturing the ciliary muscle forces. Prior work demonstrated strong photo-initiated bonding between strips of capsular bag and poly(2-hydroxyethyl methacrylate); (pHEMA) polymer in an extraocular setting. We demonstrate that photobonding can be achieved intraocularly. Methods: Phacoemulsification was performed in porcine eyes (<24 hours postmortem). A commercial intraocular lens (IOL; pHEMA-MMA material) was inserted in the capsular bag. Surface contact between the lens and capsular bag was ensured by continuous air infusion into the anterior chamber of the eye, which provided sufficient pressure at the interface, as well as oxygen. The capsular bag and IOL then were stained with 0.1% photosensitizer Rose Bengal (RB) solution. A fiberoptic probe connected to a diode-laser (532 nm) was used to locally irradiate the capsular bag–IOL interface intraocularly. The bonding breaking load was evaluated in a uniaxial stretcher. Results: Photobonding occurred in the 0.8 to 1.6 W/cm irradiance range and 2.5 to 7 minutes irradiation time. Average forces of 0.12 N stretched but did not break the bond. These forces, applied uniaxially, are higher than the summed net accommodating force of the ciliary muscle along the entire equator (0.08 N). In two cases, the zonulae broke before the bonded region. Conclusions: Photobonding between the capsular bag and IOL polymer can be achieved intraocularly, in a procedure compatible with standard cataract surgery. This technique will enable the mechanisms of A-IOLs not to rely on capsular bag integrity or natural haptic fibrosis. Translational Relevance: Intraocular photobonding holds promise to enable operation of A-IOLs to restore accommodation in presbyopia, affecting 100% of the population <45 years old. Intraocular bonding of polymer material to ocular tissue also may find other applications in ophthalmology., This study was funded by the European Research Council under the European Union’s Seventh Framework Programme (FP7/2007-2013)/ERC Grant Agreement ERC-2011-AdG-294099 to SM. The current study was also supported by the Spanish government grants FIS2014-56643-R and FIS2017-84753-R to SM; and the FIS2013-49544-EXP to CD. The authors want to thank the Surface Spectroscopies & Surface Plasmon Photonics Group (Instituto de Estructura de la Materia, CSIC) for technical assistance.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Adaptation to interocular differences in blur

  • Kompaniez, E.
  • Sawides, L.
  • Marcos, Susana
  • Webster, M.A.
14 pags., 9 figs., Adaptation to a blurred image causes a physically focused image to appear too sharp, and shifts the point of subjective focus toward the adapting blur, consistent with a renormalization of perceived focus. We examined whether and how this adaptation normalizes to differences in blur between the two eyes, which can routinely arise from differences in refractive errors. Observers adapted to images filtered to simulate optical defocus or different axes of astigmatism, as well as to images that were isotropically blurred or sharpened by varying the slope of the amplitude spectrum. Adaptation to the different types of blur produced strong aftereffects that showed strong transfer across the eyes, as assessed both in a monocular adaptation task and in a contingent adaptation task in which the two eyes were simultaneously exposed to different blur levels. Selectivity for the adapting eye was thus generally weak. When one eye was exposed to a sharper image than the other, the aftereffects also tended to be dominated by the sharper image. Our results suggest that while shortterm adaptation can rapidly recalibrate the perception of blur, it cannot do so independently for the two eyes, and that the binocular adaptation of blur is biased by the sharper of the two eyes' retinal images., This study was supported by EY-10834 (MW), Spanish Government Formacion de Personal Investigador (FPI) Predoctoral Fellowship (LS), FIS2008- 02065 (SM) and FIS2011-25637 (SM), and European Research Council ERC-2011-AdG-294099 (SM).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Isolated human crystalline lens spherical aberration: Experimental measurements and predictions from OCT-based geometry

  • Mohamed, Ashik
  • Williams, Siobhan
  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Ruggeri, Marco
  • Maceo Heilman, B.
  • Chang, Yu-Cherng
  • Geetha Sravani, N.
  • Rowaan, Cornelis
  • González, Alex
  • Sri Durgam, Shravya
  • Ho, Arthur
  • Augusteyn, Robert
  • Parel, Jean Marie
  • Marcos, Susana
  • Manns, Fabrice
ARVO Annual Meeting Abstract (2019), Support National Eye Institute Grants 1F30EY027162, 2R01EY021834, P30EY14801 (Center Grant); the Australian Federal Government CRC Scheme through the Vision Cooperative Research Centre; the Hyderabad Eye Research Foundation; Florida Lions Eye Bank and the Beauty of Sight Foundation; the Henri and Flore Lesieur Foundation (JMP); an unrestricted grant from Research to Prevent Blindness, European Research Council ERC-AdG 294099 and CSIC iCoop Program., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Perceptual and physical limits to temporal multiplexing simulation of multifocal corrections

  • Dorronsoro, Carlos
  • Rodríguez-López, Víctor
  • Barcala, Xoana
  • Gambra, Enrique
  • Akondi, Vyas
  • Sawides, L.
  • Marrakchi, Y.
  • Lage, Eduardo
  • Geisler, Wilson S.
  • Marcos, Susana
Vancouver Convention Centre, Vancouver, B.C., April 28 – May 2 (2019) . -- ARVO Annual Meeting Abstract 2019, Support Spanish Government RyC-2016-21125, PTQ-15-07432, FPU17/02760, FIS2014-56643-R, FIS2017-84753-R and ISCIII-DTS16-00127, S Madariaga MECD PRX16/00154 + Fulbright CIES FMECD-ST-2016; EU H2020 SME IA GA-739882; EIT Health; ERC-2011-AdC 294099; CAM IND2017/BMD-7670; CAM and Marie Curie Action EU FP7/2007-2013 COFUND 291820, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Testing the effect of ocular aberrations on perceived Transverse Chromatic Aberration

  • Aissati, Sara
  • Viñas, María
  • Benedi, Clara
  • Dorronsoro, Carlos
  • Marcos, Susana
ARVO Annual Meeting Abstract (2019), Support Spanish Government Grant FIS2014-56643-R Spanish Government Grant FIS2017-84753-R European Project Presbyopia ERC-2011-AdG Ref. 294099 Spanish Government Predoctoral Grant FPU16/01944, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Crystalline lens Gradient Index Profile in the guinea pig myopia model

  • Marcos, Susana
  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Revuelta, Luis
  • McFadden, Sally A.
ARVO Annual Meeting Abstract (2019), Support European Research Council ERC-2011-AdG 294099; Spanish Government FIS2014-56643-R, FIS2017-84753-R; H-2020-MSCA-COFUND-2015 713694, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Perceived best focus and visual performance upon induction of astigmatism in presbyopes

  • Benedi, Clara
  • Velasco Ocaña, Miriam
  • Dorronsoro, Carlos
  • Hernández, Martha
  • Marín, Gildas
  • Marcos, Susana
ARVO Annual Meeting Abstract (2019), Support a collaborative agreement with Essilor International, France. Spanish government grant FIS2014-56643-R, Spanish government grant FIS2017-84753-R, European Research Council under the European Union’s Seventh Framework Programme (FP7/2007-2013) ERC-2011-AdG-294099, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Intra-Ocular Lens Power Calculation using 3D OCT-based Personalized Computer Eye Models

  • Castro, Alberto de
  • Martínez-Enríquez, Eduardo
  • Velasco Ocaña, Miriam
  • Durán, Sonia
  • Jiménez-Alfaro, Ignacio
  • Marcos, Susana
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019, Support European Research Council (ERC) under European Union’s Horizon 2020 research and innovation programme H2020-MSCA-COFUND-2015-FP-713694, Spanish government grant FIS2014-56643-R, European Research Council under the European Union’s Seventh Framework programme ERC-2011-AdG-294099, Patent P201130685, Patent US2016 62/329,392​., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Eigenlenses: an eigenvectors-based model for full crystalline lens shape description

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Mohamed, Ashik
  • Ruggeri, Marco
  • Williams, Siobhan
  • Parel, Jean Marie
  • Manns, Fabrice
  • Marcos, Susana
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019., Support Spanish Government Grant FIS2014-56643-R; Spanish Government Grant FIS2017-84753-R; European Project Presbyopia ERC-2011-AdG Ref. 294099; National Eye Institute Grants 2R01EY021834, P30EY14801 (Center Grant); the Hyderabad Eye Research Foundation; Florida Lions Eye Bank and the Beauty of Sight Foundation; Drs KR Olsen and ME Hildebrandt; Drs R Urs and A Furtado; the Henri and Flore Lesieur Foundation (JMP); an unrestricted grant from Research to Prevent Blindness., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Optical and visual quality with physical and visually simulated presbyopic multifocal contact lenses

  • Viñas, María
  • Aissati, Sara
  • González-Ramos, Ana M.
  • Romero, Mercedes
  • Sawides, L.
  • Akondi, Vyas
  • Gambra, Enrique
  • Dorronsoro, Carlos
  • Martínez-Enríquez, Eduardo
  • Karkkainen, T.
  • Nankivil, D.
  • Marcos, Susana
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019, Support European Research Council ERC-2011-AdG-294099; Spanish Government: FIS2017-84753-R, PTQ-15-07432, and ISCIII DTS16/00127; Spanish Goverment predoctoral program FPU16/01944; Collaborative agreement with Johnson & Johnson Vision, Inc., Jacksonville, FL, USA, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Perceptual differences across binocular corrections for presbyopia

  • Barcala, Xoana
  • Viñas, María
  • Gambra, Enrique
  • Marcos, Susana
  • Dorronsoro, Carlos
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019., Support Spanish Government Grant FIS2014-56643-R; FIS2017-84753-R; ISCIII​ DTS16/00127; PTQ-15-07432; CAM IND2017/BMD7670; European Project Presbyopia ERC-2011-AdG 294099, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Assessment of asymmetries in biomechanical properties from corneal deformation imaging

  • Birkenfeld, Judith S.
  • Germann, James
  • Castro, Alberto de
  • Hoz, A. de la
  • Curatolo, Andrea
  • Marcos, Susana
This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019, Support European Project Multiply H-2020-MSCA-COFUND-2015 Ref. 713694, Spanish Government Grant FIS2017-84753-R, European Project Presbyopia ERC-2011-AdG Ref. 294099, European Project Imcustomeye H2020-ICT-2017 Ref. 779960, BES-2015-072197, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Full shape crystalline lens geometrical changes with age from 3-D OCT images in vivo and ex vivo

  • Martínez-Enríquez, Eduardo
  • Mohamed, Ashik
  • Ruggeri, Marco
  • Velasco Ocaña, Miriam
  • Williams, Siobhan
  • Maceo Heilman, B.
  • Castro, Alberto de
  • Pérez Merino, Pablo
  • Geetha Sravani, N.
  • Sangwan, Virender
  • Parel, Jean Marie
  • Augusteyn, Robert
  • Ho, Arthur
  • Manns, Fabrice
  • Marcos, Susana
This is an abstract that was submitted for the 2018 ARVO Annual Meeting, held in Honolulu, Hawaii, April 29 - May 3, 2018, Support NEI Grants: R01EY021834, F31EY021444 (Maceo), P30EY14801 (Center Grant); the Florida Lions Eye Bank; Research to Prevent Blindness; Australian Federal Government CRC Program (Vision CRC); Drs. KR Olsen and ME Hildebrandt, Drs. Raksha Urs and Aaron Furtado, the Henri and Flore Lesieur Foundation (JMP); Hyderabad Eye Research Foundation, European Research Council ERC-AdG 294099, FIS2014-56643-R and CSIC iCoop Program., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Visual benefit of correcting High Order Aberrations in blue or green light: an optical effect?

  • Marcos, Susana
  • Benedi, Clara
  • Viñas, María
  • Dorronsoro, Carlos
  • Burns, Stephen A.
  • Peli, E.
This is an abstract that was submitted for the 2018 ARVO Annual Meeting, held in Honolulu, Hawaii, April 29 - May 3, 2018, Support European Research Council ERC-2011-AdG-294099; Spanish Government FIS2014, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Comparison of multifocal visual simulations in patients before and after implantation of diffractive trifocal lenses

  • Viñas, María
  • Romero, Mercedes
  • Aissati, Sara
  • Méndez-González, Juan Luis
  • Benedi, Clara
  • Gambra, Enrique
  • Akondi, Vyas
  • Garzón, N.
  • Poyales, F.
  • Dorronsoro, Carlos
  • Marcos, Susana
This is an abstract that was submitted for the 2018 ARVO Annual Meeting, held in Honolulu, Hawaii, April 29 - May 3, 2018., Support European Research Council ERC-2011-AdG-294099; Spanish Government: FIS2014-56643-R, PTQ-15-07432, and ISCIII DTS16/00127; Collaborative agreement with Physiol (Liege, Belgium), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Full shape crystalline lens quantification from 3-D OCT images and its application to predict the post-operative IOL position

  • Martínez-Enríquez, Eduardo
  • Pérez Merino, Pablo
  • Sun, M.
  • Durán-Poveda, Sonia
  • Jiménez-Alfaro, Ignacio
  • Marcos, Susana
This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017., Support ERC Grant Agreement [ERC-2011-AdC- 294099] and FIS2014-56643-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Fluorescence Depth Measurements of Rose Bengal Diffused into Cornea and pHEMA measured by Two-photon Fluorescence Microscopy

  • Germann, James
  • Gutierrez-Contreras, R.
  • Dorronsoro, Carlos
  • Kochevar, Irene E.
  • Marcos, Susana
This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017., Support ERC-2011-AdG-294099, FIS2014-56643, FIS2013-49544-EXP, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

MAS: The Multifocal Acceptance Score

  • Dorronsoro, Carlos
  • Méndez-González, Juan Luis
  • Gambra, Enrique
  • Alejandre, Nicolás
  • Pérez Merino, Pablo
  • Marcos, Susana
This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017, Support European Research Council ERC-2011-AdG-294099; ERC-PoC-713422 (SimVisSim); Spanish Government FIS2014, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Intraocular photobonding for accommodating intraocular lenses

  • Gutierrez-Contreras, R.
  • Alejandre, Nicolás
  • Dorronsoro, Carlos
  • Marcos, Susana
This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017., Support European Research Conuncil ERC-2011-AdG-294099; Spanish Government FIS2014-56643R and FIS2013-49544-EXP, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Quantitative 3-D OCT ocular geometry of lens-treated myopic and hyperopic guinea pig eyes

  • Pérez Merino, Pablo
  • Martínez-Enríquez, Eduardo
  • Velasco Ocaña, Miriam
  • Revuelta, Luis
  • Marcos, Susana
  • McFadden, Sally A.
This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017, Support FIS2014-56643; FIS2011-25637; ERC-2011-AdG-294099; G1400967 HMRI, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

In vivo measurement of longitudinal chromatic aberration with multifocal diffractive intraocular lenses

  • Viñas, María
  • González-Ramos, Ana M.
  • Dorronsoro, Carlos
  • Akondi, Vyas
  • Garzón, N.
  • Poyales, F.
  • Marcos, Susana
This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017, Support European Research Council ERC-2011-AdG-294099; Spanish Government FIS2014; Collaborative agreement with Physiol (Liege, Belgium), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Quantifying crystalline lens geometry and optical properties by combined optical coherence tomography & laser ray tracing

  • Mohamed, Ashik
  • Ruggeri, Marco
  • Martínez-Enríquez, Eduardo
  • Pérez Merino, Pablo
  • Williams, Siobhan
  • Yao, Yue
  • Maceo Heilman, B.
  • Castro, Alberto de
  • Singh Sangwan, Virender
  • Augusteyn, Robert
  • Parel, J. M. A.
  • Ho, Arthur
  • Marcos, Susana
  • Manns, Fabrice
This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017, Support NIH R01EY021834, R01EY014225 and P30EY14801, the Australian Federal Government CRC Scheme through the Vision Cooperative Research Centre, Florida Lions Eye Bank, Research to Prevent Blindness, Drs KR Olsen and ME Hildebrandt, Drs Raksha Urs and Aaron Furtado, Henri and Flore Lesieur Foundation (JMP), Hyderabad Eye Research Foundation, European Research Council ERC-AdG 294099 and CSIC iCoop Program, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Simulating multifocal intraocular lenses with a spatial light modulator and a tunable lens: a computational evaluation

  • Akondi, Vyas
  • Gambra, Enrique
  • Viñas, María
  • Aissati, Sara
  • Dorronsoro, Carlos
  • Pascual, Daniel
  • Marcos, Susana
This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017, Support The research leading to these results has received funding from Consejería de Educación, Juventud y Deporte of Comunidad de Madrid and the People Programme (Marie Curie Actions) of the European Union’s Seventh Framework Programme ( FP7/2007-2013) under REA grant agreement n°291820 to VA, Spanish Government Grant FIS2014-56643-R and European Research Council (ERC) (ERC-2011-AdG 294099) to SM., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Visual simulations of real multifocal lenses in a multi-channel Adaptive Optics system

  • Marcos, Susana
  • Viñas, María
  • Benedi, Clara
  • Aissati, Sara
  • Akondi, Vyas
  • Barcala, Xoana
  • Gambra, Enrique
This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017, Support ERC-2011-AdG 294099; FIS2014-56643-R; H2020 COFUND Marie Curie 291820; ERC-PoC SimVisSim, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Biomechanical properties and IOP reconstruction from air-puff corneal deformation imaging: validations in model and porcine eyes

  • Bekesi, Nandor
  • Dorronsoro, Carlos
  • Marcos, Susana
This is an abstract that was submitted for the 2016 ARVO Annual Meeting, held in Seattle, Wash., May 1-5, 2016, Support Comunidad de Madrid & EU Marie Curie (FP7/2007-2013/REA 291820), ERC Advanced Grant 294099, Spanish Government Grant FIS2014-56643-R, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Testing vision with physical and simulated multifocal corrections in an adaptive optics visual simulator

  • Viñas, María
  • Dorronsoro, Carlos
  • Radhakrishnan, Aiswaryah
  • LaVilla, Edward Anthony
  • Schwiegerling, Jim
  • Marcos, Susana
This is an abstract that was submitted for the 2016 ARVO Annual Meeting, held in Seattle, Wash., May 1-5, 2016, Support Spanish Government FIS2011-25637, FIS2014-56643 and FPU Programs; European Research Council ERC-2011-AdG-294099; CSIC JAE Predoctoral Program, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Subjective preference to orientation of an angular bifocal IOL design

  • Radhakrishnan, Aiswaryah
  • Dorronsoro, Carlos
  • Marcos, Susana
This is an abstract that was submitted for the 2016 ARVO Annual Meeting, held in Seattle, Wash., May 1-5, 2016., Support FIS2011-25637; ERC-2011-AdG-294099; EU Marie Curie FP7-PEOPLE-2010-ITN #26405; FIS2014-56643, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Vision with different presbyopia corrections simulated with a portable binocular visual simulator

  • Dorronsoro, Carlos
  • Radhakrishnan, Aiswaryah
  • Pascual, Daniel
  • Marcos, Susana
This is an abstract that was submitted for the 2016 ARVO Annual Meeting, held in Seattle, Wash., May 1-5, 2016., Support FIS2014-56643; FIS2011-25637; ERC-2011-AdG-294099, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Design and evaluation of a surface-changing accommodating IOL

  • Hoz, A. de la
  • Martínez-Enríquez, Eduardo
  • Subhash, Hrebesh
  • Pascual, Daniel
  • Bekesi, Nandor
  • Dorronsoro, Carlos
  • Alejandre, Nicolás
  • Marcos, Susana
This is an abstract that was submitted for the 2016 ARVO Annual Meeting, held in Seattle, Wash., May 1-5, 2016., Support ERC-AdG-294099; FIS2011; FIS2014., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

3-D OCT-based guinea pig eye model: Relating morphology & optics

  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Martínez-Enríquez, Eduardo
  • Revuelta, Luis
  • McFadden, Sally A.
  • Marcos, Susana
This is an abstract that was submitted for the 2016 ARVO Annual Meeting, held in Seattle, Wash., May 1-5, 2016, Support FIS2014-56643; FIS2011-25637; ERC-2011-AdG-294099, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Crystalline lens volume, diameter and equator estimates from OCT images: impact on future paradigms of cataract surgery

  • Martínez-Enríquez, Eduardo
  • Sun, M.
  • Birkenfeld, Judith S.
  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Marcos, Susana
This is an abstract that was submitted for the 2016 ARVO Annual Meeting, held in Seattle, Wash., May 1-5, 2016., Support ERC-2011- AdG 294099, FIS2011-25637, FIS2014-56643, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Neural interpretation of optical blur and its impact on image quality perception

  • Marcos, Susana
This is an abstract that was submitted for the 2016 ARVO Annual Meeting, held in Seattle, Wash., May 1-5, 2016., Support Spanish Government FIS2011-25637 (SM), the European Research Council ERC-AdG-294099 (SM), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Collagen arrangement from Second Harmonic Microscopy in corneas following cross-linking

  • Germann, James
  • Martínez-Enríquez, Eduardo
  • Marcos, Susana
This is an abstract that was submitted for the 2016 ARVO Annual Meeting, held in Seattle, Wash., May 1-5, 2016, Support ERC-2011-AdG-294099, FIS2014-56643, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Quantitative OCT-based longitudinal evaluation of intracorneal ring segment implantation in keratoconus

  • Pérez Merino, Pablo
  • Ortiz, Sergio
  • Alejandre, Nicolás
  • Jiménez-Alfaro, Ignacio
  • Marcos, Susana
12 pags., 14 figs., 1 tab., Purpose. To characterize the geometrical properties of keratoconic corneas upon intracorneal ring segments (ICRS) implantation, using custom-developed optical coherence tomography (OCT). Methods. Ten keratoconic corneas were measured pre- and post-ICRS surgery (7, 30, and 90 days). Corneal topographic and pachymetric maps were obtained from three-dimensional (3D) images acquired with OCT, provided with custom algorithms for image analysis, distortion correction, and quantification. The 3D positioning of the ICRS was also estimated longitudinally, relative to the pupil center and iris plane. Results. Preoperatively, the average corneal radii of curvature were 7.02 ± 0.54 mm (anterior) and 5.40 ± 0.77 mm (posterior), and the minimum corneal thickness was 384 ± 60 μm. At 90 days, the average corneal radii of curvature were 7.26 ± 0.53 mm (anterior) and 5.44 ± 0.71 mm (posterior), and the minimum corneal thickness was 396 ± 46 μm. ICRS implantation produced a significant decrease of corneal power (by 1.71 ± 1.83 diopters [D] at 90 days). Corneal irregularities (defined by high order Zernike terms of the corneal elevation maps) and the corneal thickness distribution decreased in some patients and increased in others. The 3D ICRS depth matched the planned ICRS depth well (within 23.93 ± 23.49 μm). On average, ICRS showed an overall tilt of -6.8 ± 2.6° (temporal) and -2.1 ± 0.8° (superior) at 7 days. Conclusions. Spectral OCT (sOCT) provided with distortion correction and analysis tools, is an excellent instrument for evaluating the changes produced by ICRS in keratoconic corneas, and for analyzing the 3D ICRS position during the follow up. ICRS produced flattening on the anterior corneal surface, although the benefit for corneal surface regularization varied across patients. © 2013 The Association for Research in Vision and Ophthalmology, Inc., Supported by funding from the European Research Council under the European Union’s Seventh Framework Programme (FP7/2007- 2013)/European Research Council Grant Agreement Number 294099. This study has been also supported by Ministerio de Educacion y Ciencia, Spain (Grants FIS2011-25637, CEN-2091021), ´ and European Union Grant EURHORCs-ESF (SM). Authors also acknowledge Unidad Asociada IO-CSIC/FJD.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Influence of shape and gradient refractive index in the accommodative changes of spherical aberration in nonhuman primate crystalline lenses

  • Castro, Alberto de
  • Birkenfeld, Judith S.
  • Maceo, B. M.
  • Manns, Fabrice
  • Arrieta, Esdras
  • Parel, Jean Marie
  • Marcos, Susana
11 pags., 8 figs., Purpose. To estimate changes in surface shape and gradient refractive index (GRIN) profile in primate lenses as a function of accommodation. To quantify the contribution of surface shape and GRIN to spherical aberration changes with accommodation. Methods. Crystalline lenses from 15 cynomolgus monkeys were studied in vitro under different levels of accommodation produced by a stretching system. Lens shape was obtained from optical coherence tomography (OCT) cross-sectional images. The GRIN was reconstructed with a search algorithm using the optical path measured from OCT images and the measured back focal length. The spherical aberration of the lens was estimated as a function of accommodation using the reconstructed GRIN and a homogeneous refractive index. Results. The lens anterior and posterior radii of curvature decreased with increasing lens power. Both surfaces exhibited negative asphericities in the unaccommodated state. The anterior surface conic constant shifted toward less negative values with accommodation, while the value of the posterior remained constant. GRIN parameters remained constant with accommodation. The lens spherical aberration with GRIN distribution was negative and higher in magnitude than that with a homogeneous equivalent refractive index (by 29% and 53% in the unaccommodated and fully accommodated states, respectively). Spherical aberration with the equivalent refractive index shifted with accommodation toward negative values (-0.070 lm/diopter [D]), but the reconstructed GRIN shifted it farther (-0.124 lm/ D). Conclusions. When compared with the lens with the homogeneous equivalent refractive index, the reconstructed GRIN lens has more negative spherical aberration and a larger shift toward more negative values with accommodation. © 2013 The Association for Research in Vision and Ophthalmology, Inc., Supported by a Spanish government Grant FIS2011-25637 and the European Research Council ERC-AdG-294099 (SM); CSIC JAE-Pre Program fellowship (JB); CSIC i-LINKþ 2012, iLINKþ0609 (SM, J-MP); National Eye Institute Grants 2R01EY14225, 1R01EY021834, 1F31EY021444 (NSRA Individual Predoctoral Fellowship [BM]), P30EY14801 (Center Grant); the Florida Lions Eye Bank; the Henri and Flore Lesieur Foundation (J-MP); Research to Prevent Blindness; the Vision Cooperative Research Centre, Sydney, New South Wales, Australia; and the Australian Federal Government through the Cooperative Research Centres Programme
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Optical quality and subjective judgments of blur under pure simultaneous vision.

  • Dorronsoro, Carlos
  • Radhakrishnan, Aiswaryah
  • Sawides, L.
  • Marcos, Susana
ARVO 2013 Annual Meeting, May 5-9, 2013, Washington State Convention Center, FIS2011-25637; ERC-2011-AdG-294099; EU Marie Curie FP7-PEOPLE-2010- ITN #26405
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Optical quality and subjective judgments of blur under pure simultaneous vision.

  • Dorronsoro, Carlos
  • Radhakrishnan, Aiswaryah
  • Sawides, L.
  • Marcos, Susana
ARVO 2013 Annual Meeting, May 5-9, 2013, Washington State Convention Center, FIS2011-25637; ERC-2011-AdG-294099; EU Marie Curie FP7-PEOPLE-2010- ITN #26405
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Three dimensional biometry and alignment in eyes implanted with Accommodative IOLs as a function of accommodative demand

  • Marcos, Susana
  • Ortiz, Sergio
  • Pérez Merino, Pablo
  • Velasco Ocaña, Miriam
  • Sun, M.
  • Birkenfeld, Judith S.
  • Durán, Sonia
  • Jiménez-Alfaro, Ignacio
ARVO Annual Meeting 2013, Washington State Convention Center, May 5-9, 2013, Spanish Government Grant FIS2011-25637; European Research Council ERC2011 AdG-294099; EU Marie Curie FP7-PEOPLE-2010-ITN 264605; CSIC JAE-Program; Unidad Asociada IO-CSIC/FJD
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Visual performance under natural, corrected and Adaptive Optics induced astigmatism: meridional and adaptational effects.

  • Viñas, María
  • Gracia, Pablo de
  • Dorronsoro, Carlos
  • Sawides, L.
  • Marín, Gildas
  • Hernández, Martha
  • Marcos, Susana
ARVO Annual Meeting 2013, Washington State Convention Center, May 5-9, 2013, Spanish Goverment FIS2008-02065, FIS2011-25637, and FPU Programs; European Research Council ERC-2011-AdG-294099; CSIC JAE Predoctoral Program ; Essilor International Colaborative agreement
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Dependence of subjective image focus on the magnitude and pattern of high order aberrations.

  • Sawides, L.
  • Dorronsoro, Carlos
  • Gracia, Pablo de
  • Viñas, María
  • Webster, Michael
  • Marcos, Susana
12 pags., 8 figs., The image formed by the eye's optics is inherently blurred by aberrations specific to the individual's eyes. We examined to what extent judgments of perceived focus depend on the total magnitude as opposed to the specific pattern of blur introduced by the eye's high order aberrations (HOA). An Adaptive Optics system was used to simultaneously correct each subject's wave aberrations and display natural images blurred by simulated aberrations. To isolate the effects of blur magnitude, images were blurred by pure symmetric defocus, and subjects judged the level of the defocus that subjectively appeared best focused (i.e., neither too blurred nor too sharp). These settings were strongly correlated with the native blur magnitude. To isolate the effect of the HOA pattern, retinal image blur was instead maintained at a constant blur (Strehl Ratio) equal to each subject's natural blur, and subjects judged the best-focused image from pairs of images blurred by different patterns of HOA, one selected from 100 patterns, the other blurred by a reference pattern which included the subject's natural HOA, rotated HOA, or nine other HOA patterns. The percentage of images judged as best focused was not systematically higher when filtered with the subject's own HOA pattern. However, all subjects preferred their own HOA to the rotated version significantly more often (57% versus 45% on average across subjects). The representation of subjective image focus thus appears to be driven primarily by the overall amount of blur and only weakly by HOA blur orientation., Financial support was provided by a MICINN FPI Predoctoral Fellowship to Lucie Sawides; a CSIC JAE Predoctoral Fellowship to Pablo de Gracia; a MICINN FPU Predoctoral Fellowship to Maria Vinas; EY10834 to Michael Webster; and MICINN FIS2008- 02065, FIS2011-25637, EURYI-05-102-ES (EU RHORCs-ESF), and ERC-2011-AdG-294099 to Susana Marcos.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology

  • Marcos, Susana
  • Martínez-Enríquez, Eduardo
  • Viñas, María
  • Castro, Alberto de
  • Dorronsoro, Carlos
  • Bang, Seung Pil
  • Yoon, Geunyoung
  • Artal, Pablo
32 pags., 10 figs., As the human eye ages, the crystalline lens stiffens (presbyopia) and opacifies (cataract), requiring its replacement with an artificial lens [intraocular lens (IOL)]. Cataract surgery is the most frequently performed surgical procedure in the world. The increase in IOL designs has not been paralleled in practice by a sophistication in IOL selection methods, which rely on limited anatomical measurements of the eye and the surgeon's interpretation of the patient's needs and expectations. We propose that the future of IOL selection will be guided by 3D quantitative imaging of the crystalline lens to map lens opacities, anticipate IOL position, and develop fully customized eye models for ray-tracing-based IOL selection. Conversely, visual simulators (in which IOL designs are programmed in active elements) allow patients to experience prospective vision before surgery and to make more informed decisions about which IOL to choose. Quantitative imaging and optical and visual simulations of postsurgery outcomes will allow optimal treatments to be selected for a patient undergoing modern cataract surgery., The authors have received funding from the following sources: H2020-MSCA-ITN-2015- 675137 IMCUSTOMEYE (S.M.); ERC-2011-AdG-294099 PRESBYOPIA (S.M.); ERC-PoCOCT4IOL (S.M.); ERC-PoC-SimVisSim (S.M.); ERC-2018-AdG-833106-SilkEye (S.M.) and ERC-2013-AdG-339228 SEECAT (P.A.); Spanish Agencia Estatal de Investigación FIS2017- 84753-R (S.M.) and PID2019-105684RB-I00 (P.A.); Fundación Séneca-Agencia de Ciencia y Tecnología de la Región de Murcia 19897/GERM/15 (P.A.); National Institutes of Health/National Eye Institute (G.Y.); Research to Prevent Blindness (G.Y.); and NYSTAR/CEIS/CoE (G.Y.).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

SimVis simulations of multifocal IOL designs based on public-literature data

  • Sawides, L.
  • Castro, Alberto de
  • Lago, Carmen M.
  • Barcala, Xoana
  • Zaytouny, Amal
  • Marcos, Susana
  • Dorronsoro, Carlos
12 pags., 10 figs., As a large variety of intraocular lens (IOL) designs is commercially available in a growing market, selecting the best IOL for each patient has become a crucial task for a positive surgical outcome. Information about the measured or estimated performance of commercial lenses, as the through-focus modulation transfer function (TF-MTF) at a given frequency and pupil diameter, is routinely published. SimVis Gekko, a see-through simultaneous vision simulator based on temporal multiplexing, allows patients to experience the real world through different multifocal corrections prior to surgery. Implementing the maximum number of commercially available IOL designs into the portfolio of SimVis Gekko simulations is needed to provide a complete experience for the patients. We developed a new method to visually simulate IOL designs using temporal multiplexing, based only on publicly available information (mainly scientific literature or regulatory information), using the TF-MTF at 15cpd as input data to estimate the temporal coefficients that provide the best approximation to the real lens design. We validated the method with synthetic phase maps of equal area segmented bifocal and trifocal multifocal corrections for three pupil diameters of 3mm, 3.75mm and 4.5mm and applied it to three commercially available IOLs (trifocal or extended-depth-of-focus lenses). Through-focus visual acuity (TF-VA) curves were measured in seven patients using the SimVis simulations in the SimVis Gekko and matched, on average, the throughfocus VA measurements in patients with implanted IOLs, reported in the scientific literature (on average logMAR RMS error=0.05, corresponding to less than 3 letters of visual acuity charts)., We acknowledge financial support from the European Research Council ERC-2011-AdC 294099 (SM) from the Spanish Government FIS2017-84753R (SM), ISCIII DTS16/00127 (CD) and from Madrid Regional Government Doctorado Industrial IND2017/BMD-7670 (XB) and IND2018/BMD-9809 (CL)
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Applications of Adaptive Optics Visual Simulators

  • Aissati, Sara
  • Viñas, María
  • Benedi, Clara
  • González-Ramos, Ana M.
  • Vedhakrishnan, Shrilekha
  • Marcos, Susana
XIII Reunión Nacional de Óptica. -- Evento online, 22-24 noviembre 2021, Spanish Government (FIS2014-56643R, FIS2017-84753R, FPU16/01944, ISCIII DTS16/00127); European Research Council (ERC-2011-AdC 294099, ERC-2019-AdG-833106); H2020 Marie Skłodowska-Curie Actions H2020-MSCA (IF-GF-2019-MYOMICRO-893557 & COFUND 291820 program)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Eigenlenses: A new model for full crystalline lens shape representation and its applications

  • Martínez-Enríquez, Eduardo
  • Castro, Alberto de
  • Marcos, Susana
17 pages, 8 figures, 1 table, The crystalline lens is an important optical element in the eye, responsible for focusing, and which experiences significant changes throughout life. The shape of the lens is usually studied only in the optical area (central 4 to 6 mm). However, for a great number of applications, a description of the full shape of the crystalline lens is required. We propose a new method for the representation of the full shape of the crystalline lens, constructed from 3-dimensional optical coherence tomography images of 133 isolated crystalline lenses (0-71 y/o), which we have called eigenlenses. The method is shown to be compact and accurate to describe not only the full shape of the crystalline lens, but also the optical zone in comparison with other methods. We also demonstrate its application to the extrapolation of the full shape of the crystalline lens from in-vivo optical images of the anterior segment of the eye, where only the central part of the lens visible through the pupil is available, and in the generation (synthesis) of realistic full lenses of a given age. The method has critical applications, among others, in improving and evaluating myopia and presbyopia treatments., H2020 European Research Council (H2020-MSCA COFUND-2015 FP-713694, MULTIPLY (AdC));Ministerio de Economía y Competitividad (FIS2017-84753-R); Horizon2020 Framework Programme (IMCUSTOMEYE Ref. 779960 (H2020-ICT- 2017-1)); European Research Council (ERC-2011-AdG-294099); National Institutes of Health (R01EY021834).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

From Astronomy to the clinic: Adaptive Optics based visual simulators

  • Viñas, María
3 pages, 2 figures, Adaptive optics based visual simulators with deformable mirrors, spatial light modulators or optotunable lenses are increasingly used to simulate vision through different complex multifocal lens designs. Their final utility in the clinic relies on their capability to predict visual performance after an ocular surgery., European Research Council (ERC-2011-AdC 294099); H2020 Marie Skłodowska-Curie Actions (H2020 COFUND Marie Curie 291820 program); Spanish Goverment (FIS2014-56643R, FIS2017-84753R, FPU16/01944, ISCIII DTS16/00127); Private company PhysIOL (Collaborative agreement).