Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

Biblos-e Archivo. Repositorio Institucional de la UAM
Publication Artículo científico (JournalArticle)

Interfacing neurons with nanostructured electrodes modulates synaptic circuit features

  • Domínguez-Bajo, Ana
  • Rodilla, Beatriz Loreto
  • Calaresu, Ivo
  • Arché-Núñez, Ana
  • González-Mayorga, Ankor
  • Scaini, Denis
  • Pérez, Lucas
  • Camarero de Diego, Julio
  • Miranda Soriano, Rodolfo
  • López-Dolado, Elisa
  • González, María Teresa
  • Ballerini, Laura
  • Serrano, María Concepción
Understanding neural physiopathology requires advances in nanotechnology-based interfaces, engineered to monitor the functional state of mammalian nervous cells. Such interfaces typically contain nanometer-size features for stimulation and recording as in cell-non-invasive extracellular microelectrode arrays. In such devices, it turns crucial to understand specific interactions of neural cells with physicochemical features of electrodes, which could be designed to optimize performance. Herein, versatile flexible nanostructured electrodes covered by arrays of metallic nanowires are fabricated and used to investigate the role of chemical composition and nanotopography on rat brain cells in vitro. By using Au and Ni as exemplary materials, nanostructure and chemical composition are demonstrated to play major roles in the interaction of neural cells with electrodes. Nanostructured devices are interfaced to rat embryonic cortical cells and postnatal hippocampal neurons forming synaptic circuits. It is shown that Au-based electrodes behave similarly to controls. Contrarily, Ni-based nanostructured electrodes increase cell survival, boost neuronal differentiation, and reduce glial cells with respect to flat counterparts. Nonetheless, Au-based electrodes perform superiorly compared to Ni-based ones. Under electrical stimulation, Au-based nanostructured substrates evoke intracellular calcium dynamics compatible with neural networks activation. These studies highlight the opportunity for these electrodes to excite a silent neural network by direct neuronal membranes depolarization
Biblos-e Archivo. Repositorio Institucional de la UAM
Publication Artículo científico (JournalArticle)

Nanostructured gold electrodes promote neural maturation and network connectivity

Biblos-e Archivo. Repositorio Institucional de la UAM
Publication Artículo científico (JournalArticle)

Polystyrene nanopillars with inbuilt carbon nanotubes enable synaptic modulation and stimulation in interfaced neuronal networks

Biblos-e Archivo. Repositorio Institucional de la UAM
Publication Artículo científico (JournalArticle)

Key parameters for detectivity improvement of low noise anisotropic magnetoresistive sensors made of La2/3Sr1/3MnO3 single layers on vicinal substrates

  • Enger, Luiz G.
  • Flament, Stéphane
  • Bhatti, Imtiaz N.
  • Rousseau, Olivier
  • Guillet, Bruno
  • Sing, Marc Lam Chok
  • Pierron, Victor
  • Lebargy, Sylvain
  • Chaluvadi, Sandeep K.
  • Domengés, Bernadette
  • Vera, Arturo
  • Díez, Jose M.
  • Martínez, Isidoro
  • Guerrero, Rubén
  • Pérez, Lucas
  • Gonzalez, Maria T.
  • Miranda Soriano, Rodolfo
  • Camarero de Diego, Julio
  • Perna, Paolo
  • Méchin, Laurence
The current trend in magnetoresistive sensors development is to increase the sensitivity of single sensing elements by using multilayer structures and to design them into arrays. Such arrays are designed to compensate the excess low frequency noise of individual elements, which limits their magnetic resolution. Here, we report the modeling, design, and fabrication of single layer anisotropic magnetoresistive (AMR) sensors using low noise epitaxial La2/3Sr1/3MnO3 (LSMO) oxide thin films deposited on vicinal SrTiO3 substrates. The fabrication process is simple, and the operation of the sensor is based on a step-induced uniaxial magnetic anisotropy, described using the Stoner-Wohlfarth model. A coherent magnetization reversal process is observed by magneto-optical Kerr effect imaging. A good agreement between experimental data and the expected sensor response confirms the correct operation of the device. Three main fabrication parameters, namely the vicinal angle of the substrate, the deposition temperature, the thin film thickness, and their effects on film anisotropy field and device detectivity have been studied. Detectivity levels as low as 1.4 nT Hz-1/2 at 1 Hz and 240 pT Hz-1/2 in the white noise region are achieved with a single Wheatstone bridge element operating at 310 K. Compared to GMR and AMR sensors, these results are promising for further development and for their use as single layer LSMO low field AMR sensors, including applications as implantable biomedical devices, This project has received funding from the European Union Horizon 2020 research and innovation program under grant agreement No 737116. The work in Spain was supported by the Regional Government of Madrid and by the AEI through Projects P2018/NMT-4321 (NANOMAGCOST-CM) and PID2021-122980OB-C52 (ECLIPSE-ECoSOx), respectively. IMDEA Nanoscience Institute is supported by the “Severo Ochoa” Programme for Centres of Excellence in R&D, (MINECO grant SEV-2016-0686)
Biblos-e Archivo. Repositorio Institucional de la UAM
Publication Artículo científico (JournalArticle)

High-performance implantable sensors based on anisotropic magnetoresistive La0.67Sr0.33MnO3 for biomedical applications

  • Vera, Arturo
  • Diez, José Manuel
  • Miranda Soriano, Rodolfo
  • Camarero de Diego, Julio
Artículo escrito por un elevado número de autores, solo se referencian el que aparece en primer lugar, los autores pertenecientes a la UAM y el nombre del grupo de colaboración, si lo hubiere, We present the design, fabrication, and characterization of an implantable neural interface based on anisotropic magnetoresistive (AMR) magnetic-field sensors that combine reduced size and high performance at body temperature. The sensors are based on La0.67Sr0.33MnO3 (LSMO) as a ferromagnetic material, whose epitaxial growth has been suitably engineered to get uniaxial anisotropy and large AMR output together with low noise even at low frequencies. The performance of LSMO sensors of different film thickness and at different temperatures close to 37 °C has to be explored to find an optimum sensitivity of ∼400%/T (with typical detectivity values of 2 nT·Hz-1/2 at a frequency of 1 Hz and 0.3 nT·Hz-1/2 at 1 kHz), fitted for the detection of low magnetic signals coming from neural activity. Biocompatibility tests of devices consisting of submillimeter-size LSMO sensors coated by a thin poly(dimethyl siloxane) polymeric layer, both in vitro and in vivo, support their high suitability as implantable detectors of low-frequency biological magnetic signals emerging from heterogeneous electrically active tissues
Docta Complutense
Publication Artículo científico (JournalArticle)

Impact of magnetite nanowires on in vitro hippocampal neural networks

  • Cortés Llanos, Belén
  • Rauti, Rossana
  • Ayuso Sacido, Ángel
  • Pérez García, Lucas
  • Ballerini, Laura
Nanomaterials design, synthesis, and characterization are ever-expanding approaches toward developing biodevices or neural interfaces to treat neurological diseases. The ability of nanomaterials features to tune neuronal networks’ morphology or functionality is still under study. In this work, we unveil how interfacing mammalian brain cultured neurons and iron oxide nanowires’ (NWs) orientation affect neuronal and glial densities and network activity. Iron oxide NWs were synthesized by electrodeposition, fixing the diameter to 100 nm and the length to 1 µm. Scanning electron microscopy, Raman, and contact angle measurements were performed to characterize the NWs’ morphology, chemical composition, and hydrophilicity. Hippocampal cultures were seeded on NWs devices, and after 14 days, the cell morphology was studied by immunocytochemistry and confocal microscopy. Live calcium imaging was performed to study neuronal activity. Using random nanowires (R-NWs), higher neuronal and glial cell densities were obtained compared with the control and vertical nanowires (V-NWs), while using V-NWs, more stellate glial cells were found. R-NWs produced a reduction in neuronal activity, while V-NWs increased the neuronal network activity, possibly due to a higher neuronal maturity and a lower number of GABAergic neurons, respectively. These results highlight the potential of NWs manipulations to design ad hoc regenerative interfaces.
Repositorio Institucional del Instituto Madrileño de Estudios Avanzados en Nanociencia
Publication Artículo científico antes de ser publicado, versión del autor (Preprint)

Room temperature biaxial magnetic anisotropy in La0.67Sr0.33MnO3 thin films on SrTiO3 buffered MgO (001) substrates for spintronic applications

  • Kumar Chaluvadi Sandeep
  • Orgiani Pasquale
  • Rousseau Olivier
  • Vinai Giovanni
  • Yu Petrov Aleksandr
  • Torelli Piero
  • Pautrat Alain
  • Camarero, Julio
  • Perna, Paolo
  • Mechin Laurence
  • Ajejas, Fernando
Repositorio Institucional del Instituto Madrileño de Estudios Avanzados en Nanociencia
Publication Artículo científico (JournalArticle)

Room temperature biaxial magnetic anisotropy in La0.67Sr0.33MnO3 thin films on SrTiO3 buffered MgO (001) substrates for spintronic applications

  • Chaluvadi S.K.
  • Orgiani P.
  • Rousseau O.
  • Vinai G.
  • Petrov A.Y.
  • Torelli P.
  • Pautrat A.
  • Camarero, Julio
  • Perna, Paolo
  • Mechin L.
  • Ajejas, Fernando
Repositorio Institucional del Instituto Madrileño de Estudios Avanzados en Nanociencia
Publication Artículo científico (JournalArticle)

Nanostructured gold electrodes promote neural maturation and network connectivity

  • Domínguez-Bajo A.
  • Rosa J.M.
  • González-Mayorga A.
  • Rodilla B.L.
  • Arché-Núñez A.
  • Benayas E.
  • Ocón P.
  • Pérez, Lucas
  • Camarero, Julio
  • Miranda, Rodolfo
  • González, Teresa
  • Aguilar J.
  • López-Dolado E.
  • Serrano M.C.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Favorable Biological Responses of Neural Cells and Tissue Interacting with Graphene Oxide Microfibers

  • González-Mayorga, Ankor
  • López-Dolado, Elisa
  • Gutiérrez, María C.
  • Collazos-Castro, J. E.
  • Ferrer, M. Luisa
  • Monte, Francisco del
  • Serrano, María C.
Neural tissue engineering approaches show increasing promise for the treatment of neural diseases including spinal cord injury, for which an efficient therapy is still missing. Encouraged by both positive findings on the interaction of carbon nanomaterials such as graphene with neural components and the necessity of more efficient guidance structures for neural repair, we herein study the potential of reduced graphene oxide (rGO) microfibers as substrates for neural growth in the injured central neural tissue. Compact, bendable, and conductive fibers are obtained. When coated with neural adhesive molecules (poly-L-lysine and N-cadherin), these microfibers behave as supportive substrates of highly interconnected cultures composed of neurons and glial cells for up to 21 days. Synaptic contacts close to rGO are identified. Interestingly, the colonization by meningeal fibroblasts is dramatically hindered by N-cadherin coating. Finally, in vivo studies reveal the feasible implantation of these rGO microfibers as a guidance platform in the injured rat spinal cord, without evident signs of subacute local toxicity. These positive findings boost further investigation at longer implantation times to prove the utility of these substrates as components of advanced therapies for enhancing repair in the damaged central neural tissue including the injured spinal cord., This work was supported by the Instituto de Salud Carlos III-MINECO-FEDER (CP13/00060), the Ministerio de Economía y Competitividad, and the Fondo Europeo de Desarrollo Regional (MAT2016-78857-R and MAT2015-68639-R, MINECO/FEDER, UE). It was also partially funded by the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 737116.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Tesis doctoral (DoctoralThesis)

Design and development of biomaterials for spinal cord injury repair, Diseño y desarrollo de biomateriales para la reparación de la médula espinal lesionada

  • Domínguez-Bajo, Ana
[EN] Spinal cord injury (SCI) continues to be a therapeutic challenge as there is no cure to date. Thus, the implementation of novel implantable devices that could be placed at the injured tissue has been widely explored by researchers working in different areas of Tissue Engineering and Materials Science and clinicians. In this thesis, we have investigated two different substrates as potentially efficient neural interfaces based on different strategies. On the one hand, we tested the in vitro biocompatibility of 2D metal-based nanowires (NWs) that could work as nanoelectrodes. These NWs will be eventually included in a device able of acting as a bypass once placed at the lesion site after SCI. On the other hand, two kinds of biocompatible 3D scaffolds made of reduced graphene oxide (rGO) were chronically implanted in the right hemisected cervical spinal cord (C6 level) of a rat experimental model of SCI. In vivo biocompatibility, in terms of behavior affectation along with systemic and local tissue responses, was thoroughly studied four months after implantation following an interdisciplinary approach. The results obtained in this thesis demonstrate the promising potential of both NWs and rGO scaffolds as neural interfaces capable of fostering the repair of the injured spinal cord. Further studies including biological functionalization and the application of rehabilitation protocols, such as aerobic motor training, might improve their therapeutic potential by a synergistic effect of topographical, chemical, mechanical and sensory stimuli, thus boosting neural repair after SCI., [ES] Actualmente no existe ningún tratamiento eficaz para la lesión medular, caracterizada principalmente por el daño de los axones neuronales y la creación de un entorno inhibitorio para la regeneración. En esta tesis, hemos investigado dos plataformas diferentes capaces de actuar como interfaces neurales. Por un lado, hemos estudiado la biocompatibilidad in vitro de nanohilos metálicos que funcionarán como nanoelectrodos dentro de un dispositivo capaz de actuar como “bypass” en la lesión. Estos nanohilos metálicos se han fabricado por electrodeposición de níquel (Ni) u oro (Au) sobre una base plana y flexible de Au, dispuestos verticalmente sobre ella. Por otro lado, dos tipos de plataformas 3D fabricadas a partir de óxido de grafeno reducido se han implantado crónicamente en un modelo de hemisección de la médula espinal cervical en rata. Los implantes han consistido en una espuma altamente porosa y microfibras integradas en un hidrogel de gelatina. Con respecto a los electrodos metálicos, la composición química y la nanotopografía modulan el comportamiento de las células neurales in vitro. Con respecto a los biomateriales de grafeno, ambos implantes han promovido la estabilización del tejido espinal lesionado, así como la presencia de estructuras neuronales acompañadas de vasos sanguíneos en la lesión. Además, las espumas de grafeno reducen el daño perilesional y no causan efectos adversos por compresión ni tracción. En conclusión, estos resultados demuestran el potencial de estas plataformas como interfaces neurales para la reparación de la médula espinal lesionada., This thesis project has been made partially possible thanks to the financial support received from the European Union´s Horizon 2020 research and innovation programme under grant agreement No. 737116 corresponding to the ByAxon project (H2020-FET-OPEN-RIA, EC; 2017-2020)., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Interface-induced anomalous Nernst effect in Fe 3 O 4 /Pt-based heterostructures

  • Ramos, R.
  • Kikkawa, T.
  • Anadón, A.
  • Lucas, I.
  • Niizeki, T.
  • Uchida, K.
  • Algarabel, P.A.
  • Morellón, L.
  • Aguirre, M.H.
  • Ibarra, M.R.
  • Saitoh, E.
We have studied the anomalous Nernst effect (ANE) in [Fe 3 O 4 /Pt]-based heterostructures grown at high temperature, by measuring the ANE-induced electric field with a magnetic field applied normal to the sample surface, in the perpendicular magnetized configuration, where only the ANEs from the ferromagnetic layers or magnetic proximity effects can be detected. An ANE voltage is observed for [Fe 3 O 4 /Pt] n multilayers, and we further investigated its origin by performing measurements in [Fe 3 O 4 /Pt/Fe 3 O 4 ] trilayers as a function of the Pt thickness. Our results suggest the presence of an interface-induced ANE in the metallic layer, possibly driven by a heat induced subnanometer interdiffusion which affects the nature of the Fe 3 O 4 /Pt interface. Despite this ANE, the spin Seebeck effect is the dominant mechanism for the transverse thermoelectric voltage in the in-plane magnetized configuration, accounting for about 70% of the voltage in the multilayers.
Docta Complutense
Publication Artículo científico (JournalArticle)

Nanostructured gold electrodes promote neural maturation and network connectivity

  • Dominguez-Bajo, Ana
  • Rosa, Juliana M.
  • González-Mayorga, Ankor
  • Rodilla González, Beatriz Loreto
  • Arché-Nuñez, Ana
  • Benayas, Esther
  • Ocón, Pilar
  • Pérez García, Lucas
  • Camarero, Julio
  • Miranda, Rodolfo
  • González, M. Teresa
  • Aguilar, Juan
  • Lopez-Dolado, Elisa
  • Serrano, María C.
Progress in the clinical application of recording and stimulation devices for neural diseases is still limited, mainly because of suboptimal material engineering and unfavorable interactions with biological entities. Nanotechnology is providing upgraded designs of materials to better mimic the native extracellular environment and attain more intimate contacts with individual neurons, besides allowing for the miniaturization of the electrodes. However, little progress has been done to date on the understanding of the biological impact that such neural interfaces have on neural network maturation and functionality. In this work, we elucidate the effect of a gold (Au) highly ordered nanostructure on the morphological and functional interactions with neural cells and tissues. Alumina-templated Au nanostructured electrodes composed of parallel nanowires of 160 nm in diameter and 1.2 mu m in length (Au-NWs), with 320 nm of pitch, are designed and characterized. Equivalent non-structured Au electrodes (Au-Flat) are used for comparison. By using diverse techniques in in vitro cell cultures including live calcium imaging, we found that Au-NWs interfaced with primary neural cortical cells for up to 14 days allow neural networks growth and increase spontaneous activity and ability of neuronal synchronization, thus indicating that nanostructured features favor neuronal network. The enhancement in the number of glial cells found is hypothesized to be behind these beneficial functional effects. The in vivo effect of the implantation of these nanostructured electrodes and its potential relevance for future clinical applicability has been explored in an experimental model of rat spinal cord injury. Subacute responses to implanted Au-NWs show no overt reactive or toxic biological reactions besides those triggered by the injury itself. These results highlight the translational potential of Au-NWs electrodes for in vivo applications as neural interfaces in contact with central nervous tissues including the injured spinal cord.
Docta Complutense
Publication Artículo científico (JournalArticle)

Flexible metallic core–shell nanostructured electrodes for neural interfacing

  • Rodilla González, Beatriz Loreto
  • Arché-Nuñez, Ana
  • Ruiz-Gómez, Sandra
  • Domínguez-Bajo, Ana
  • Fernández-González, Claudia
  • Guillén-Colomer, Clara
  • González-Mayorga, Ankor
  • Rodríguez-Díez, Noelia
  • Camarero, Julio
  • Miranda, Rodolfo
  • López-Dolado, Elisa
  • Ocón, Pilar
  • Serrano, María Concepción
  • Pérez García, Lucas
  • González, M. Teresa
Electrodes with nanostructured surface have emerged as promising low-impedance neural interfaces that can avoid the charge‐injection restrictions typically associated to microelectrodes. In this work, we propose a novel approximation, based on a two-step template assisted electrodeposition technique, to obtain flexible nanostructured electrodes coated with core–shell Ni–Au vertical nanowires. These nanowires benefit from biocompatibility of the Au shell exposed to the environment and the mechanical properties of Ni that allow for nanowires longer and more homogeneous in length than their only-Au counterparts. The nanostructured electrodes show impedance values, measured by electrochemical impedance spectroscopy (EIS), at least 9 times lower than those of flat reference electrodes. This ratio is in good accordance with the increased effective surface area determined both from SEM images and cyclic voltammetry measurements, evidencing that only Au is exposed to the medium. The observed EIS profile evolution of Ni–Au electrodes over 7 days were very close to those of Au electrodes and differently from Ni ones. Finally, the morphology, viability and neuronal differentiation of rat embryonic cortical cells cultured on Ni–Au NW electrodes were found to besimilar to those on control (glass) substrates and Au NW electrodes, accompanied by a lower glial cell differentiation. This positive in-vitro neural cell behavior encourages further investigation to explore the tissue responses that the implantation of these nanostructured electrodes might elicit in healthy (damaged) neural tissues in vivo, with special emphasis on eventual tissue encapsulation.
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

In-vitro real-time magnetic recording of neuronal activity on spinal cord slices

  • Vera García, Arturo
  • Calaresu, Ivo
  • Martinez Ramirez, Isidoro|||0000-0002-5821-4840
  • Guerrero, Ruben|||0000-0003-2829-9377
  • Scaini, Denis|||0000-0001-8398-8074
  • Arana Schoebel, Guillermo de
  • Hernández Rueda, Jaime|||0000-0002-4368-2529
  • Rodríguez Fernández, Isabel|||0000-0002-7178-8275
  • Miranda Soriano, Rodolfo|||0000-0002-1064-6724
  • Martin, Eduardo Daniel|||0000-0003-1768-3488
  • Camarero de Diego, Julio|||0000-0003-0078-7280
  • González Pérez, María Teresa|||0000-0002-7253-797X
  • Pérez García, Lucas|||0000-0001-9470-7987
  • Ballerini, Laura|||0000-0001-8420-0787