Skip to main content

DISEÑO Y DESARROLLO DE UN BIOMATERIAL 3D BIOACTIVO DE OXIDO DE GRAFENO FUNCIONALIZADO PARA EL TRATAMIENTO DE LA LESION MEDULAR

MAT2016-78857-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2016
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre FUNDACION HOSPITAL NACIONAL DE PARAPLEJICOS

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Myelinated axons and functional blood vessels populate mechanically compliant rGO foams in chronic cervical hemisected rats

  • Domínguez-Bajo, Ana
  • González-Mayorga, Ankor
  • Guerrero, Carlos R.
  • Palomares, F. Javier
  • García-González, Ricardo
  • López-Dolado, Elisa
  • Serrano, María C.
Neural diseases at the central nervous system including spinal cord injury (SCI) remain therapeutic challenges. Graphene materials are being delineated as alternative tools for neural repair. Herein, the regenerative ability of reduced graphene oxide (rGO) scaffolds to support pivotal features of neural repair at 4 months after SCI is assessed by an interdisciplinary approach. 3D randomly porous foams have been prepared in mechanical compliance with neural cells and tissues (Young's modulus of 1.3 ± 1.0 kPa) as demonstrated by atomic force microscopy techniques applied ex vivo. After implantation, the significant increase in Young's modulus caused by massive cell/protein infiltration does not alter the mechanical performance of the contralateral spinal cord but provides mechanical stability to the lesion. These aerogels appear fully vascularized and populated with neurites, some of them being myelinated excitatory axons. Clinically-inspired magnetic resonance imaging studies demonstrate that the scaffolds significantly reduce perilesional damage with respect to rats without implants and cause no compressive damage in the contralateral hemicord and rostral/caudal regions. The rGO implants do not either alter the rat spontaneous behaviour or induce toxicity in major organs. Finally, preliminary data suggest hints of rGO sheets dissociation and eventual degradation at the injured spinal cord for the first time. In summary, these 3D porous rGO scaffolds are able to induce, without any further biological functionalization, a compilation of positive effects that have been rarely described before, if ever, for any other material implanted in the injured spinal cord to date., This work was supported by the Ministerio de Economía y Competitividad and the Fondo Europeo de Desarrollo Regional (MAT2016-78857-R, MAT2016-76507-R and MAT2016-80394-R, MINECO/FEDER, UE) and the European Research Council ERC-AdG-340177 (3DNanoMech)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Dataset of the publication "Myelinated axons and functional blood vessels populate mechanically compliant rGO foams in chronic cervical hemisected rats"

  • Domínguez-Bajo, Ana
  • González-Mayorga, Ankor
  • Guerrero, Carlos R.
  • Palomares, F. Javier
  • García García, Ricardo
  • López-Dolado, Elisa
  • Serrano, María C.
The copyright of the content of this dataset belongs to the authors of the article indicated above. Permission must be requested to the authors for the reproduction and/or use of any parts of this dataset. Access to this dataset has been made public through the use of the public repository of CSIC (DIGITAL.CSIC). For any further questions, please contact the corresponding author of the article at mc.terradas@csic.es, Spinal cord injury (SCI) remain a therapeutic challenge. In this work, we have explored the regenerative ability of reduced graphene oxide (rGO) scaffolds to support pivotal features of neural repair at 4 months after SCI. 3D randomly porous foams have been prepared in mechanical compliance with neural cells and tissues. After 4 months, these scaffolds are fully vascularized and populated with neurites, some of them identified as myelinated excitatory axons. Magnetic resonance imaging studies demonstrate reduce perilesional damage in the presence of the scaffolds. In summary, these 3D porous rGO scaffolds are able to induce a compilation of positive effects that have been rarely described before, if ever, for any other material implanted in the injured spinal cord. The techniques used in this study include: immunofluorescence, scanning electron microscopy, atomic force microscopy, transmission electron microscopy, confocal laser scanning microscopy, histology, behavioral tests, magnetic resonance imaging, and X-ray photoelectron spectroscopy., This work was supported by the Ministerio de Economía y Competitividad and the Fondo Europeo de Desarrollo Regional (MAT2016-78857-R, MAT2016-76507-R and MAT2016-80394-R, MINECO/FEDER, UE) and the European Research Council ERC-AdG-340177 (3DNanoMech)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Favorable Biological Responses of Neural Cells and Tissue Interacting with Graphene Oxide Microfibers

  • González-Mayorga, Ankor
  • López-Dolado, Elisa
  • Gutiérrez, María C.
  • Collazos-Castro, J. E.
  • Ferrer, M. Luisa
  • Monte, Francisco del
  • Serrano, María C.
Neural tissue engineering approaches show increasing promise for the treatment of neural diseases including spinal cord injury, for which an efficient therapy is still missing. Encouraged by both positive findings on the interaction of carbon nanomaterials such as graphene with neural components and the necessity of more efficient guidance structures for neural repair, we herein study the potential of reduced graphene oxide (rGO) microfibers as substrates for neural growth in the injured central neural tissue. Compact, bendable, and conductive fibers are obtained. When coated with neural adhesive molecules (poly-L-lysine and N-cadherin), these microfibers behave as supportive substrates of highly interconnected cultures composed of neurons and glial cells for up to 21 days. Synaptic contacts close to rGO are identified. Interestingly, the colonization by meningeal fibroblasts is dramatically hindered by N-cadherin coating. Finally, in vivo studies reveal the feasible implantation of these rGO microfibers as a guidance platform in the injured rat spinal cord, without evident signs of subacute local toxicity. These positive findings boost further investigation at longer implantation times to prove the utility of these substrates as components of advanced therapies for enhancing repair in the damaged central neural tissue including the injured spinal cord., This work was supported by the Instituto de Salud Carlos III-MINECO-FEDER (CP13/00060), the Ministerio de Economía y Competitividad, and the Fondo Europeo de Desarrollo Regional (MAT2016-78857-R and MAT2015-68639-R, MINECO/FEDER, UE). It was also partially funded by the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 737116.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Graphene-derived materials interfacing the spinal cord: outstanding in vitro and in vivo findings

  • Domínguez-Bajo, Ana
  • González-Mayorga, Ankor
  • López-Dolado, Elisa
  • Serrano, María C.
The attractiveness of graphene-derived materials (GDMs) for neural applications has fueled their exploration as components of biomaterial interfaces contacting the brain and the spinal cord. In the last years, an increasing body of work has been published on the ability of these materials to create biocompatible and biofunctional substrates able to promote the growth and activity of neural cells in vitro and positively interact with neural tissues when implanted in vivo. Encouraging results in the central nervous tissue might impulse the study of GDMs towards preclinical arena. In this mini-review article, we revise the most relevant literature on the interaction of GDMs with the spinal cord. Studies involving the implantation of these materials in vivo in the injured spinal cord are first discussed, followed by models with spinal cord slides ex vivo and a final description of selected results with neural cells in vitro. A closing debate of the major conclusions of these results is presented to boost the investigation of GDMs in the field., This project has received funding from the Agencia Estatal de Investigación of Spain and the Fondo Europeo de Desarrollo Regional (MAT2016-78857-R, AEI/FEDER, UE).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

3D Reduced Graphene Oxide Scaffolds with a Combinatorial Fibrous-Porous Architecture for Neural Tissue Engineering

  • Girão, André F.
  • Sousa, Joana
  • Domínguez-Bajo, Ana
  • González Mayorga, Ankor
  • Bdikin, Igor
  • Pujades Otero, Eulalia
  • Casañ Pastor, Nieves
  • Hortigüela, María J.
  • Otero Irurueta, Gonzalo
  • Completo, António
  • Serrano, María C.
  • Marques, Paula A.A.P.
Graphene oxide (GO) assists a diverse set of promising routes to build bioactive neural microenvironments by easily interacting with other biomaterials to enhance their bulk features or, alternatively, self-assembling toward the construction of biocompatible systems with specific three-dimensional (3D) geometries. Herein, we first modulate both size and available oxygen groups in GO nanosheets to adjust the physicochemical and biological properties of polycaprolactone–gelatin electrospun nanofibrous systems. The results show that the incorporation of customized GO nanosheets modulates the properties of the nanofibers and, subsequently, markedly influences the viability of neural progenitor cell cultures. Interestingly, the partially reduced GO (rGO) nanosheets with larger dimensions trigger the best cell response, while the rGO nanosheets with smaller size provoke an accentuated decrease in the cytocompatibility of the resulting electrospun meshes. Then, the most auspicious nanofibers are synergistically accommodated onto the surface of 3D-rGO heterogeneous porous networks, giving rise to fibrous-porous combinatorial architectures suitable for enhancing adhesion and differentiation of neural cells. By varying the chemical composition of the nanofibers, it is possible to adapt their performance as physical crosslinkers for the rGO sheets, leading to the modulation of both pore size and structural/mechanical integrity of the scaffold. Importantly, the biocompatibility of the resultant fibrous-porous systems is not compromised after 14 days of cell culture, including standard differentiation patterns of neural progenitor cells. Overall, in light of these in vitro results, the reported scaffolding approach presents not only an indisputable capacity to support highly viable and interconnected neural circuits but also the potential to unlock novel strategies for neural tissue engineering applications., This work was supported by the projects UIDB/00481/2020 and UIDP/00481/2020 - FCT - Fundação para a Ciência e a Tecnologia; and CENTRO-01-0145-FEDER-022083 - Centro Portugal Regional Operational Program (Centro2020), under the PORTUGAL 2020 Partnership Agreement, through the European Regional Development Fund; Agencia Estatal de Investigación of Spain and the Fondo Europeo de Desarrollo Regional (MAT2016-78857-R, AEI/FEDER, UE); RTI2018-097753-B-I00, and Severo Ochoa Program (SEV-2015-0496). A.F.G. thanks FCT for the Ph.D. grant SFRH/BD/130287/2017, which is carried out in collaboration between TEMA-UA and ICMM-CSIC. J.S. thanks FCT for the Ph.D. grant SFRH/BD/144579/2019. I.B. thanks FCT for financial support (IF/00582/2015)., Peer reviewed