Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Stability of 3D-porous Ni/Cu cathodes under real alkaline electrolyzer operating conditions and its effect on catalytic activity

  • Valero Vidal, Carlos
  • Igual Muñoz, Anna Neus
  • Herraiz Cardona, Isaac|||0000-0001-5829-6594
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
Despite the development and synthesis of new electrode materials for hydrogen generation in alkaline water electrolyzers has been a research topic widely exploited in the last years, stability tests on the obtained cathodes have been restricted to long-term potentiostatic/galvanostatic experiments which do not fulfil the real operating conditions that take place in those devices. In this work, two different Service Life Tests have been designed and implemented, aiming at including particular conditions (i.e. inverse polarity and short-circuit) in the durability and catalytic activity of cathode characterization. For this purpose, Ni/Cu bilayered porous electrodes were prepared using different Ni electrodeposition times (15, 30 and 45 min) following a double template electrochemical method. It has been confirmed that the electrode with the lowest Ni content can be considered as a promising electrocatalyst for hydrogen production under industrial conditions because of its optimal activity and stability after the two sets of testing conditions. In particular, electrochemical studies demonstrated that an inversion in polarity can positively affect the electrode performance, as a consequence of the synergetic interaction between CuO/Cu(OH)(2) and beta-Ni(OH)(2) species formed at potentials below the oxygen evolution domain., The authors gratefully acknowledge financial support given by the Generalitat Valenciana (PROMETEO/2010/023) and Spanish Government (Ministerio de Ciencia e Innovation) for the postgraduate grants AP2007-01243 (Carlos Valero-Vidal) and AP2007-03737 (Isaac Herraiz-Cardona).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Effect of physico-chemical properties of simulated body fluids on the electrochemical behaviour of CoCrMo alloy

  • Valero Vidal, Carlos
  • Igual Muñoz, Anna Neus
The behaviour of the CoCrMo alloy was studied under different experimental conditions of solution pH, chemical composition (phosphate buffer solution with and without addition of bovine serum albumin) and aeration (presence and absence of oxygen in the solution). With this purpose, electrochemical techniques such as open circuit measurements (OCP), potentiodynamic curves, potentiostatic tests and electrochemical impedance spectroscopy (EIS) were employed. The results show that the general corrosion behaviour of CoCrMo alloy depends on the solution pH. Thus, the effect of BSA and the aeration conditions are related to the solution pH. At pH 3 no influence of BSA was observed in deoxygenated solutions which imply that BSA acts over the oxygen reduction reaction in acidic media. On the contrary, a noticeable influence of BSA addition was observed at pH 7.4 (independently on the gas content). Finally, at pH 10, the influence of BSA was only significant in oxygenated solution. It was found that H(2)PO(4-) favours the formation of passivating compounds which improves the resistance of the CoCrMo alloy to passive dissolution. Therefore, when the concentration of the H(2)PO(4-) increases (when pH decreases) the polarization resistance of the alloy also increases. On the other hand, the oxygen (aerated conditions) decreases the polarization resistance of the alloy in all the studied conditions., We wish to express our gratitude to the Spanish Government, "Ministerio de Educacion" for the economic support and the postgraduate grant (Ref. AP2007-01243).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Passivation of a CoCrMo PVD Alloy with Biomedical Composition under Simulated Physiological Conditions Studied by EQCM and XPS

  • Valero Vidal, Carlos
  • Igual Muñoz, Anna Neus
  • Olsson, C.O.A.
  • Mischler, Stefano
Kinetics of passive film growth on a CoCrMo biomedical alloy have been studied using the Electrochemical Quartz Crystal Microbalance technique (EQCM) in phosphate buffer solution at room temperature and 37◦C. CoCrMo layers were deposited on the quartz crystals by physical vapor deposition (PVD) reaching a dense and compact deposition film with fine-grain structure. EQCM measurements were performed under potentiodynamic and potentiostatic conditions (at applied passive and transpassive potentials). Furthermore, ex-situ X-ray Photoelectron Spectroscopy (XPS) analysis of the each tested sample was performed at the end of the electrochemical test. The use ofEQCMallows distinguishing between electrochemical oxidation, passive and transpassive dissolution and passive film growth. In the passive domain the passive film thickness stabilizes within 200 to 400 s after an initial fast growth. The increase in current at the onset of the transpassive domain does not affect the passive dissolution rate. Only at higher potential dissolution rate increases due to the dissolution of Cr(VI), Co(III) and Mo(VI) species. The observed constant mass loss rate at transpassive potentials indicates that the passive film at these potentials is cracked or porous. Increasing temperature accelerates themass loss through the oxide/electrolyte interface enhancing the passive and transpassive dissolution and increasing the thickness of the oxide film, We wish to express our gratitude to the Spanish Government, "Ministerio de Educacion" for the economic support and the post-graduate grant (Ref.AP2007-01243) and "Ministerio de Ciencia e Innovacion" for the financial support (Ref.MAT2011-22481), the assistance of N. Xanthopoulos with the XPS measurements and P. Mettraux with the PVD deposits and assistance with the scanning electron micrographs.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Adsorption of BSA on Passivated CoCrMo PVD Alloy: An EQCM and XPS Investigation

  • Valero Vidal, Carlos
  • Igual Muñoz, Anna Neus
  • Olsson, Claes
  • Mischler, Stefano
[EN] Adsorption of Bovine Serum Albumin (BSA) on an anodically passivated CoCrMo biomedical alloy has been studied using the Electrochemical Quartz Crystal Microbalance (EQCM) in phosphate buffer solution at 37 degrees C. CoCrMo layers were deposited on the quartz crystals by physical vapor deposition. EQCM measurements were performed under potentiostatic conditions and combined with X-ray Photoelectron Spectroscopy (XPS) analysis. Adsorption of BSA onto the CoCrMo alloy surface was found to favor passive dissolution without modification of the chemical composition and thickness of the oxide passive film. In addition, passive film growth and adsorption kinetics of the protein follow a logarithmic trend. Both EQCM and XPS techniques demonstrated that protein coverage depends on the applied potential. (C) 2014 The Electrochemical Society. All rights reserved., We express our gratitude to the Spanish Government, "Ministerio de Economia y Competitividad" for the economic support (project reference MAT2011-22481) and the post-graduate grant (Ref.AP2007-01243), the assistance of N. Xanthopoulos with the XPS measurements and P. Mettraux with the PVD deposits.