Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Engineering Interpenetrating Polymer Networks of Poly(2-Hydroxyethyl Acrylate) as Ex Vivo Platforms for Articular Cartilage Regeneration

  • Poveda Reyes, Sara
  • Gamboa Martínez, Tatiana Carolina
  • Manzano, Sara
  • Doweidar, Mohamed Hamdy
  • Ochoa Garrido, Ignacio
  • Gómez Ribelles, José Luís|||0000-0001-9099-0885
  • Gallego-Ferrer, Gloria|||0000-0002-2428-0903
A hydrogel based on interpenetrating polymer networks (IPNs) has been designed to act as a platform in an articular cartilage bioreactor for the ex vivo test of scaffolds, simulating the host tissue. Poly(2-hydroxyethyl acrylate) (PHEA) has been mechanically reinforced by its interpenetration with poly(ethyl acrylate). The resulting IPNs are phase separated systems with a porosity that increases with the amount of PHEA. Compression Young s modulus decreases and permeability increases when increasing the PHEA content in the samples, being the IPN with a 79% of PHEA the best candidate to mimic articular cartilage., The authors gratefully acknowledge the financial support from the Spanish Ministry of Economy and Competitiveness through the MAT2013-46467-C4-1-R and MAT2013-46467-C4-3-R projects (including the FEDER financial support), the FPU AP2010/2557 and the FPI BES-2011-046144 PhD grants, and the CIBER-BBN. CIBER-BBN is an initiative funded by the VI National R&D&I Plan 2008-2011, Iniciativa Ingenio 2010, Consolider Program. CIBER Actions are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund. The translation of this paper was funded by the Universitat Politecnica de Valencia, Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Computational analysis of cartilage implants based on an interpenetrated polymer network for tissue repairing

  • Manzano, Sara
  • Poveda Reyes, Sara
  • Ochoa, Ignacio
  • Doweidar, Mohamed Hamdy
  • Gallego-Ferrer, Gloria|||0000-0002-2428-0903
[EN] Interpenetrating polymer networks (IPNs)—two independent polymer networks that interpenetrate in space—are valuable systems for controlling the permeability and mechanical properties of hydrogels for biomedical applications. In particular, poly(ethyl acrylate) (PEA)–poly(2-hydroxyethyl acrylate) (PHEA) IPNs have been explored as hydrogels to mimic articular cartilage. These networks are proposed as scaffold implants in cartilage defects to maintain continuous fluid transport and prevent tissue deterioration. Permeability is a key parameter that governs oxygen and nutrient transport and the removal of cellular waste, and thus strongly influences implant success. While optimization is often pursued via trial-and-error experiments, computational simulation can provide a more exhaustive way to screen cartilage-mimicking biomaterials and avoid costly, time-consuming testing. Accurate and efficient prediction of permeability and of the internal direction and magnitude of fluid flow is highly useful for biomaterial design. Here, we present a 3D computational model based on the Sussman–Bathe hyperelastic material behavior. A fluid–structure analysis is performed with ADINA, modeling these materials as two-phase composites in which a fluid saturates a deformable solid skeleton. The model simulates three non-biodegradable hydrogel compositions with varying PEA/PHEA ratios. Specifically, the study aims to (i) verify the suitability of the Sussman–Bathe material model to reproduce the response of PEA–PHEA biomaterials; (ii) predict fluid flux and the permeability of the proposed IPN hydrogels; and (iii) identify material domains where reduced transport could lead to inadequate flux distributions relative to healthy cartilage. The results show that the model predicts the permeability of PEA–PHEA hydrogels and captures their internal behavior, including the spatial distribution and quantification of fluid flux., The authors gratefully acknowledge the financial support from the Spanish Ministry of Economy and Competitiveness through the MINECO MAT2013-46467-C4-1-R and MAT2013-46467-C4-3-R projects, the FPU AP2010/2557 and the FPI BES-2011-046144 PhD grants and the CIBER-BBN initiative. CIBER-BBN is financed by the Instituto de Salud Carlos III with the assistance from the European Regional Development Fund. The authors would like to thank Mauro Malve, PhD and Theodore Sussman, PhD for their helpful suggestions with ADINA software.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Parameter-dependent behavior of articular cartilage: 3D mechano-electrochemical computational model

  • Manzano Martínez, Sara
  • Doblaré Castellano, Manuel
  • Hamdy Doweidar, Mohamed
Background and objective Changes in mechano-electrochemical properties of articular cartilage play an essential role in the majority of cartilage diseases. Despite of this importance, the specific effect of each parameter into tissue behavior remains still obscure. Parametric computational modeling of cartilage can provide some insights into this matter, specifically the study of mechano-electrochemical properties variation and their correlation with tissue swelling, water and ion fluxes. Thus, the aim of this study is to evaluate the influence of the main mechanical and electrochemical parameters on the determination of articular cartilage behavior by a parametric analysis through a 3D finite element model. Methods For this purpose, a previous 3D mechano-electrochemical model, developed by the same authors, of articular cartilage behavior has been used. Young's modulus, Poisson coefficient, ion diffusivities and ion activity coefficients variations have been analyzed and quantified through monitoring tissue simulated response. Results Simulation results show how Young's modulus and Poisson coefficient control tissue behavior rather than electrochemical properties. Meanwhile, ion diffusivity and ion activity coefficients appear to be vital in controlling velocity of incoming and outgoing fluxes. Conclusions This parametric study establishes a basic guide when defining the main properties that are essential to be included into computational modeling of articular cartilage providing a helpful tool in tissue simulations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Altered Mechano-Electrochemical Behavior of Articular Cartilage in Populations with Obesity

  • Manzano, Sara
  • Doblare, Manuel
  • Hamdy Doweidar, Mohamed
Obesity, one of the major problems in modern society, adversely affects people’s health and increases the risk of suffering degeneration in supportive tissues such as cartilage, which loses its ability to support and distribute loads. However, no specific research regarding obesity-associated alterations in the mechano-electrochemical cartilage environment has been developed. Such studies could help us to understand the first signs of cartilage degeneration when body weight increases and to establish preventive treatments to avoid cartilage deterioration. In this work, a previous mechano-electrochemical computational model has been further developed and employed to analyze and quantify the effects of obesity on the articular cartilage of the femoral hip. A comparison between the obtained results of the healthy and osteoarthritic cartilage has been made. It shows that behavioral patterns of cartilage, such as ion fluxes and cation distribution, have considerable similarities with those obtained for the early stages of osteoarthritis. Thus, an increment in the outgoing ion fluxes is produced, resulting in lower cation concentrations in all the cartilage layers. These results suggest that people with obesity, i.e. a body mass index greater than 30 kg/m2, should undergo preventive treatments for osteoarthritis to avoid homeostatic alterations and, subsequent, tissue deterioration.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Inhomogeneous response of articular cartilage: A three-dimensional multiphasic heterogeneous study

  • Manzano, Sara
  • Armengol, Monica
  • J.Price, Andrew
  • A.Hulley, Philippa
  • S.Gill, Harinderjit
  • Doblaré, Manuel
  • Hamdy Doweidar, Mohamed
Articular cartilage exhibits complex mechano-electrochemical behaviour due to its anisotropy, inhomogeneity and material non-linearity. In this work, the thickness and radial dependence of cartilage properties are incorporated into a 3D mechano-electrochemical model to explore the relevance of heterogeneity in the behaviour of the tissue. The model considers four essential phenomena: (i) osmotic pressure, (ii) convective and diffusive processes, (iii) chemical expansion and (iv) three-dimensional through-the-thickness heterogeneity of the tissue. The need to consider heterogeneity in computational simulations of cartilage behaviour and in manufacturing biomaterials mimicking this tissue is discussed. To this end, healthy tibial plateaus from pigs were mechanically and biochemically tested in-vitro. Heterogeneous properties were included in the mechano-electrochemical computational model to simulate tissue swelling. The simulation results demonstrated that swelling of the heterogeneous samples was significantly lower than swelling under homogeneous and isotropic conditions. Furthermore, there was a significant reduction in the flux of water and ions in the former samples. In conclusion, the computational model presented here can be con- sidered as a valuable tool for predicting how the variation of cartilage properties affects its behaviour, opening up possibilities for exploring the requirements of cartilage-mimicking biomaterials for tissue engineering. Besides, the model also allows the establishment of behavioural patterns of swelling and of water and ion fluxes in articular cartilage.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Cartilage Dysfunction in ALS Patients as Side Effect of Motion Loss: 3D Mechano-Electrochemical Computational Model

  • Manzano, Sara
  • Gaffney, Eamonn A.
  • Doblaré, Manuel
  • Hamdy Doweidar, Mohamed
Amyotrophic lateral sclerosis (ALS) is a debilitating motor neuron disease characterized by progressive weakness, muscle atrophy, and fasciculation. This fact results in a continuous degeneration and dysfunction of articular soft tissues. Specifically, cartilage is an avascular and nonneural connective tissue that allows smooth motion in diarthrodial joints. Due to the avascular nature of cartilage tissue, cells nutrition and by-product exchange are intermittently occurring during joint motions. Reduced mobility results in a change of proteoglycan density, osmotic pressure, and permeability of the tissue. This work aims to demonstrate the abnormal cartilage deformation in progressive immobilized articular cartilage for ALS patients. For this aim a novel 3D mechano-electrochemical model based on the triphasic theory for charged hydrated soft tissues is developed. ALS patient parameters such as tissue porosity, osmotic coefficient, and fixed anions were incorporated. Considering different mobility reduction of each phase of the disease, results predicted the degree of tissue degeneration and the reduction of its capacity for deformation. The present model can be a useful tool to predict the evolution of joints in ALS patients and the necessity of including specific cartilage protectors, drugs, or maintenance physical activities as part of the symptomatic treatment in amyotrophic lateral sclerosis.