Skip to main content

CARACTERIZACION METROLOGICA DE SUPERFICIES MICROESTRUCTURADAS

DPI2015-69403-C3-1-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2015
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Dirección General de Investigación Científica y Técnica
Beneficiary centre UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Experimental approach for the uncertainty assessment of 3D complex geometry dimensional measurements using computed tomography at the mm and sub-mm scales

  • Jiménez, Roberto
  • Torralba, Marta
  • Yagüe Fabra, José Antonio
  • Ontiveros, Sinué
  • Tosello, Guido
The dimensional verification of miniaturized components with 3D complex geometries is particularly challenging. Computed Tomography (CT) can represent a suitable alternative solution to micro metrology tools based on optical and tactile techniques. However, the establishment of CT systems’ traceability when measuring 3D complex geometries is still an open issue. In this work, an alternative method for the measurement uncertainty assessment of 3D complex geometries by using CT is presented. The method is based on the micro-CT system Maximum Permissible Error (MPE) estimation, determined experimentally by using several calibrated reference artefacts. The main advantage of the presented method is that a previous calibration of the component by a more accurate Coordinate Measuring System (CMS) is not needed. In fact, such CMS would still hold all the typical limitations of optical and tactile techniques, particularly when measuring miniaturized components with complex 3D geometries and their inability to measure inner parts. To validate the presented method, the most accepted standard currently available for CT sensors, the Verein Deutscher Ingenieure/Verband Deutscher Elektrotechniker (VDI/VDE) guideline 2630-2.1 is applied. Considering the high number of influence factors in CT and their impact on the measuring result, two different techniques for surface extraction are also considered to obtain a realistic determination of the influence of data processing on uncertainty. The uncertainty assessment of a workpiece used for micro mechanical material testing is firstly used to confirm the method, due to its feasible calibration by an optical CMS. Secondly, the measurement of a miniaturized dental file with 3D complex geometry is carried out. The estimated uncertainties are eventually compared with the component’s calibration and the micro manufacturing tolerances to demonstrate the suitability of the presented CT calibration procedure. The 2U/T ratios resulting from the validation workpiece are, respectively, 0.27 (VDI) and 0.35 (MPE), by assuring tolerances in the range of +- 20–30 micro-m. For the dental file, the EN < 1 value analysis is favorable in the majority of the cases (70.4%) and 2U/T is equal to 0.31 for sub-mm measurands (L < 1 mm and tolerance intervals of +- 40–80 micro-m).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Geometrical characterisation of a 2D laser system and calibration of a cross-grid encoder by means of a self-calibration methodology

  • Torralba, M.
  • Díaz-Pérez, L.C.
  • Valenzuela, M.
  • Albajez, J.A.
  • Yagüe-Fabra, J.A.
This article presents a self-calibration procedure and the experimental results for the geometrical characterisation of a 2D laser system operating along a large working range (50 mm × 50 mm) with submicrometre uncertainty. Its purpose is to correct the geometric errors of the 2D laser system setup generated when positioning the two laser heads and the plane mirrors used as reflectors. The non-calibrated artefact used in this procedure is a commercial grid encoder that is also a measuring instrument. Therefore, the self-calibration procedure also allows the determination of the geometrical errors of the grid encoder, including its squareness error. The precision of the proposed algorithm is tested using virtual data. Actual measurements are subsequently registered, and the algorithm is applied. Once the laser system is characterised, the error of the grid encoder is calculated along the working range, resulting in an expanded submicrometre calibration uncertainty (k = 2) for the X and Y axes. The results of the grid encoder calibration are comparable to the errors provided by the calibration certificate for its main central axes. It is, therefore, possible to confirm the suitability of the self-calibration methodology proposed in this article.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Implementation of the control strategy for a 2D nanopositioning long range stage

  • Díaz-Pérez, L.C.
  • Torralba, M.
  • Albajez, J.A.
  • Yagüe-Fabra, J.A.
A 2D-platform stage able to obtain an effective metrological positioning with nanometer resolution and long working range (50 x 50 mm2) is on development at the University of Zaragoza. The 2D stage has already been designed, manufactured and assembled. The movement of the platform is performed by four custom-made linear motors, and mirror laser interferometers work as positioning sensors in XYRz degrees of freedom. The work here presented focuses on the hardware implementation of the motor control, for one actuator on a 1D linear stage. The developed control strategy acts on three-phase PWM (Pulse-Width Modulation) signals and a feedback is provided by measuring the phase currents. As a preliminary solution, a sensorless algorithm substitutes the positioning sensor before implementing the laser interferometers.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A surface extraction analysis in a multi-material test part for computed tomography in metrology applications

  • Jiménez-Pacheco, R.
  • Ontiveros, S.
  • Yagüe-Fabra, J.A.
The main advantage of Computed Tomography is the capability of making measurements of non-accessible internal features in a test piece. One of the cases that can usually be found in this sense is the contact zone between two elements that are forming a common surface boundary, where the main complexity is to determine which surface belongs to which piece. Nowadays, this kind of surfaces are measurable only by utilizing Computed Tomography, taking into account that the characteristics of the Tomography can significantly vary depending on the material of the elements that are in contact. In this article a piece that has two different interfaces is analyzed: a Piece in contact with Air, and Material A in contact with Material B. Three different surface extraction algorithms are analyzed for multi-material parts, Threshold, Canny and Deriche, and the results and conclusions obtained are presented.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Analysis of surface extraction methods based on gradient operators for computed tomography in metrology applications

  • Ontiveros, S.
  • Jiménez, R.
  • Yagüe-Fabra, J.A.
  • Torralba, M.
Among the multiple factors influencing the accuracy of Computed Tomography measurements, the surface extraction process is a significant contributor. The location of the surface for metrological applications is generally based on the definition of a gray value as a characteristic of similarity to define the regions of interest. A different approach is to perform the detection or location of the surface based on the discontinuity or gradient. In this paper, an adapted 3D Deriche algorithm based on gradient information is presented and compared with a previously developed adapted Canny algorithm for different surface types. Both algorithms have been applied to nine calibrated workpieces with different geometries and materials. Both the systematic error and measurement uncertainty have been determined. The results show a significant reduction of the deviations obtained with the Deriche-based algorithm in the dimensions defined by flat surfaces.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Vector control strategy for halbach linear motor implemented in a commercial control hardware

  • Díaz-Pérez, L.C.
  • Albajez, J.A.
  • Torralba, M.
  • Yagüe-Fabra, J.A.
Halbach linear motors are selected as actuators in positioning stages because they present numerous advantages in precision engineering. These motors generate a horizontal and a vertical force. Whereas the horizontal force is used to perform the movement, the vertical force can be leveraged for the levitation of the moving part of the stage. This paper proposes a vector control strategy that enables the positioning of the motor while regulating the generated vertical force. In contrast to other research projects, this work implements the control strategy in a commercial control hardware. The use of commercial hardware facilitates the applicability and replication of the developed control strategy. The selected hardware is a generic Digital Motor Control Kit of Texas Instruments. The hardware implementation of the control strategy is analysed in detail in order to understand and optimize the control system. The developed control is first validated by simulation, where the error contributors are included. Then, an experimental validation is carried out. The results demonstrate that the control strategy enables the positioning of the motor along its complete operating range and the regulation of the vertical force when the motor is static, as well as while it is moving to a target position.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

One-Dimensional Control System for a Linear Motor of a Two-Dimensional Nanopositioning Stage Using Commercial Control Hardware

  • Diaz Perez, L.C.
  • Torralba Gracia, M.
  • Albajez Garcia, J.A.
  • Yague Fabra, J.A.
A two-dimensional (2D) nanopositioning platform stage (NanoPla) is in development at the University of Zaragoza. To provide a long travel range, the actuators of the NanoPla are four Halbach linear motors. These motors present many advantages in precision engineering, and they are custom made for this application. In this work, a one-dimensional (1D) control strategy for positioning a Halbach linear motor has been developed, implemented, and experimentally validated. The chosen control hardware is a commercial Digital Motor Control (DMC) Kit from Texas Instruments that has been designed to control the torque or the rotational speed of rotative motors. Using a commercial control hardware facilitates the applicability of the developed control system. Nevertheless, it constrains the design, which needs to be adapted to the hardware and optimized. Firstly, a dynamic characterization of the linear motor has been performed. By leveraging the dynamic properties of the motor, a sensorless controller is proposed. Then, a closed-loop control strategy is developed. Finally, this control strategy is implemented in the control hardware. It was verified that the control system achieves the working requirements of the NanoPla. It is able to work in a range of 50 mm and perform a minimum incremental motion of 1 mu m.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Comparison of surface extraction techniques performance in computed tomography for 3D complex micro-geometry dimensional measurements

  • Torralba, M.
  • Jiménez, R.
  • Yagüe-Fabra, J.A.
  • Ontiveros, S.
  • Tosello, G.
The number of industrial applications of computed tomography (CT) for dimensional metrology in 100–103 mm range has been continuously increasing, especially in the last years. Due to its specific characteristics, CT has the potential to be employed as a viable solution for measuring 3D complex micro-geometries as well (i.e., in the sub-mm dimensional range). However, there are different factors that may influence the CT process performance, being one of them the surface extraction technique used. In this paper, two different extraction techniques are applied to measure a complex miniaturized dental file by CT in order to analyze its contribution to the final measurement uncertainty in complex geometries at the mm to sub-mm scales. The first method is based on a similarity analysis: the threshold determination; while the second one is based on a gradient or discontinuity analysis: the 3D Canny algorithm. This algorithm has proven to provide accurate results in parts with simple geometries, but its suitability for 3D complex geometries has not been proven so far. To verify the measurement results and compare both techniques, reference measurements are performed on an optical coordinate measuring machine (OCMM). The systematic errors and uncertainty results obtained show that the 3D Canny adapted method slightly lower systematic deviations and a more robust edge definition than the local threshold method for 3D complex micro-geometry dimensional measurements.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Trajectory definition with high relative accuracy (HRA) by parametric representation of curves in nano-positioning systems

  • Díaz Pérez, Lucía
  • Rubio Serrano, Beatriz
  • Albajez García, José A.
  • Yagüe Fabra, José A.Y
  • Mainar Maza, Esmeralda
  • Torralba Gracia, Marta
Nanotechnology applications demand high accuracy positioning systems. Therefore, in order to achieve sub-micrometer accuracy, positioning uncertainty contributions must be minimized by implementing precision positioning control strategies. The positioning control system accuracy must be analyzed and optimized, especially when the system is required to follow a predefined trajectory. In this line of research, this work studies the contribution of the trajectory definition errors to the final positioning uncertainty of a large-range 2D nanopositioning stage. The curve trajectory is defined by curve fitting using two methods: traditional CAD/CAM systems and novel algorithms for accurate curve fitting. This novel method has an interest in computer-aided geometric design and approximation theory, and allows high relative accuracy (HRA) in the computation of the representations of parametric curves while minimizing the numerical errors. It is verified that the HRA method offers better positioning accuracy than commonly used CAD/CAM methods when defining a trajectory by curve fitting: When fitting a curve by interpolation with the HRA method, fewer data points are required to achieve the precision requirements. Similarly, when fitting a curve by a least-squares approximation, for the same set of given data points, the HRA method is capable of obtaining an accurate approximation curve with fewer control points.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Positioning uncertainty of the control system for the planar motion of a nanopositioning platform

  • Díaz-Pérez, Lucía
  • Torralba, Marta
  • Albajez, José Antonio
  • Yagüe Fabra, José Antonio
The novel nanopositioning platform (NanoPla) that is in development at the University of Zaragoza has been designed to achieve nanometre resolution in a large working range of 50 mm × 50 mm. The 2D movement is performed by four custom-made Halbach linear motors and a 2D laser system provides positioning feedback, while the moving part of the platform is levitating and unguided. As control hardware, this work proposes the use of a commercial solution, in contrast to other systems, where the control hardware and software were specifically designed for the purpose. In a previous work of this research, the control system of one linear motor implemented in the selected commercial hardware was presented. In this study, the developed control system is extended to the four motors of the nanopositioning platform to generate a 2D planar movement in the whole working range of the nanopositioning platform. In addition, the positioning uncertainty of the control system is assessed. The obtained results satisfy the working requirements of the NanoPla, achieving a positioning uncertainty of ±0.5 µm along the whole working range.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Additive manufacturing with vat polymerization method for precision polymer micro components production

  • Davoudinejad, Ali
  • Díaz-Pérez, Lucía C.
  • Quagliotti, Danilo
  • Pedersen, David Bue
  • Albajez, José A.
  • Yagüe, José A.
  • Tosello, Guido
The direct fabrication of miniaturized polymer components by Additive Manufacturing (AM) processes is a remarkable method at the micro dimensional scale. However, the measurement of complex micro products and the evaluation of the related uncertainty are still particularly challenging and necessary in the micro AM field. In the DTU, a proprietary Vat Photopolymerization machine able to produce micro features has been designed, built and validated. This study evaluates the capability of the machine in terms of printed dimensions and the corresponding uncertainty assessment. For this purpose, two test parts with micro features of different geometries and dimensions have been designed and five samples of each test part have been printed. The dimensions of the micro features have been evaluated for quality control capability assessment and to stablish procedures for verification of AM machines.