Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 12
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Numerical calculation of ferrofluid optical transmission evolution after magnetic field switch-on

  • Sanz-Felipe, Ángel
  • Martín, Juan Carlos
A method to calculate the optical transmission evolution of a ferrofluid after exposure to an external magnetic field is proposed. In the first part of this work, a simulation program is employed to simulate the nanoparticle rearrangement for different particle concentrations and different magnetic field intensities. In the second part, the simulated particle distributions'' optical response is determined by means of a mixture law, which avoids typical huge computational times associated to this stage of the calculation. Experimental and simulated results with both parallel and perpendicular magnetic field orientations with respect to the incident light are compared. A significant correlation is obtained, which proves the usefulness of the proposed method in order to obtain the optical transmission evolution of a ferrofluid.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Large field Digital Image Plane Holography with a double cavity high speed laser

  • Lobera, Julia
  • Arroyo, Mª Pilar
  • Roche, Eva Mª
  • Andrés, Nieves
  • Sancho, Irene
  • Vernet, Antón
  • Pallarés, Jordi
  • Palero, Virginia
The three velocity components in a fluid plane can be measured by applying Digital Image Plane Holography. This technique is limited by the laser coherence length, which reduces its application with high speed lasers that, generally, have a very short coherence length. In addition, the use of a double cavity can also imply a small wavelength difference between the two laser beams. In this work, we present an improved Optical Path Length Enlarging Device that allows the velocity measurement, in a 2D field whose width is four times larger than the laser coherence length. The optical set-up and the procedure for measuring in a larger field (ten times the laser coherence length) were optimized, and the issues derived from the laser spatial and temporal coherence and wavelength changes were analyzed and solved. Digital Image Plane Holography with the Optical Path Length Enlarging Device and Particle Image Velocimetry were applied for measuring the whole velocity field in the central plane of a cylindrical cavity with a rotating lid, for two Reynolds numbers (800 and 2000), showing both of them a very good agreement with the numerical simulations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Far field diffraction of gratings with two roughness levels

  • Torcal-Milla, F.J.
  • Sanchez-Brea, L.M.
We investigate the far field diffraction process produced by diffraction gratings with two roughness levels, such as steel tape gratings, which are used in environments where diffraction gratings made of glass are not possible. We obtain the analytical formulation describing the formation of diffraction orders in terms of the roughness parameters. Since roughness is stochastic, we use the mutual coherence function to propagate the field to the Fraunhofer regime. We conclude that diffraction orders exists when at least one correlation length of both roughness is larger than the period of the grating and the standard deviation on heights is around or larger than the illumination wavelength. Finally, we corroborate the analytical results with numerical simulations based on the fast Fourier transform, showing a high agreement.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Advances in interferometric techniques for the analysis of the three-dimensional flow in a lid-driven cylindrical cavity

  • López, Ana M.
  • Lobera, Julia
  • Andrés, Nieves
  • Arroyo, M.Pilar
  • Palero, Virginia
  • Sancho, Irene
  • Vernet, Antón
  • Pallarés, Jordi
Abstract: In this work, a qualitative and quantitative characterization of the three-dimensional flow in a lid-driven cylindrical cavity with different optical techniques is presented. Mach–Zehnder interferometry and photographic techniques have been used for a qualitative description of some flow features. However, the real challenge is to obtain quantitative measurements, as the cavity dimensions and geometry prevent the application of 3D digital techniques for measuring the flow velocity in the whole cavity with enough spatial resolution. Digital in-line holography was applied to the measure of the vortex-breakdown bubble that appears near the cavity bottom at Re = 2000. A 22 × 22 × 80 mm3 volume was recorded, its longest dimension parallel to the camera optical axis. This large volume in a liquid fluid combined with a high particle density forces us to develop new analysis strategies. Holograms have been analyzed using a new method, called Adaptive Cross Correlation with Tracking From Beginning, which includes the use of the reconstructed complex amplitude for particle localization. Particle tracking is based on the three-dimensional cross correlation of three-dimensional interrogation windows. The particle set defined in the first hologram is always used to find the particle position in subsequent holograms. This method provides an accurate 3D velocity map and the vortex-breakdown bubble spatial structure. Experimental and numerical data show a very good agreement. A new criterion for determining the accuracy in the particle position along the optical axis is introduced, achieving a spatial resolution of 0.1 mm. This tracking method can be applied not only to laminar flows but also to turbulent flows.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Tilted illumination in-line holographic velocimetry: Improvements in the axial spatial resolution

  • Lobera, Julia
  • Palero, Virginia
  • Roche, Eva
  • Gómez Climente, Marina
  • López Torres, Ana M.
  • Andrés, Nieves
  • Arroyo, M. Pilar
Two are the main limitations of in-line holography: the twin image problem and the poor spatial resolution in the optical axis direction. The twin image problem can be solved with the introduction of an imaging lens and a knife-edge aperture located at its focal plane. In this work, a theoretical analysis of the axial resolution with and without aperture is provided from the perspective of the Optical Diffraction Tomography. Theoretical analysis and controlled experiments with the different recording options, demonstrate that a small tilt of the illumination beam, together with a centered rectangular aperture, is a key parameter as it improves the spatial resolution along the optical axis during the location and tracking of a particle field.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Digital holography applied to simultaneously measure the shape and the radial deformation of a blood vessel (ex-vivo)

  • Andrés, Nieves
  • Pinto, Cristina
  • Lobera, Julia
  • López, Ana M.
  • Palero, Virginia
  • Arroyo, M. Pilar
Radial deformation of blood vessels has been measured by combining shape and deformation measurements. The difficulty of measuring both magnitudes simultaneously is related to the different order of magnitude. The veins have diameters up to 20 mm and suffer micrometric deformations due to cardiac movement. Temporal comparison of two-wavelength multiplexed holograms has been used for calculations. The radius value was calculated from the information of the vein shape, obtained by means of double wavelength holography, while the deformation of the vein has been measured with traditional holographic interferometry. In this work, both techniques have been combined using only one recording system. The technique has been tested in a latex tube and in a sheep aorta (ex-vivo). The experiments in both cases have been designed to simulate real patient situations. Differences found between the model and real vessels are presented in the paper.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Analysis of temperature dependence in ferrofluid optical transmission dynamics after magnetic field commutation

  • Sanz-Felipe, Á.
  • Martín, J.C.
The influence of temperature on the ferrofluid magneto-optical response after magnetic field commutation is studied. Its contribution to the diffusion and mobility of the ferrofluid nanoparticles is considered by means of thermal agitation and the temperature-dependent viscosity of the fluid. Experimental responses after magnetic field switch on and off show a significant dependence on temperature. Taking into account both mentioned thermal influences, a qualitative description is provided, in which viscosity turns out to play an important role. In addition, a model based on an adaptation of a paramagnetic gas theory is used to analyze the transmission relaxation evolution after magnetic field switch off. The results are in good agreement with the experimental measurements, demonstrating the validity of this adaptation to consider the temperature dependence of this response.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Full-color multiplexed reflection hologram of diffusing objects recorded by using simultaneous exposure with different times in photopolymer Bayfol® HX

  • Vázquez-Martín I.
  • Marín Sáez J.
  • Gómez Climente M.
  • Chemisana D.
  • Collados Collados, MV.
  • Atencia Carrizo J.
An optimized wavelength multiplexing procedure for color reflection holograms of diffusing objects recorded in Bayfol® HX photopolymer is proposed. It is based on simultaneous initial illumination of all the wavelengths and sequential shuttering down of the laser beams involved. Three lasers of 442 nm, 532 nm and 633 nm were selected, as a tradeoff solution between setup complexity and color reproduction accuracy. The obtained results prove that the presented method improves the simultaneous and sequential exposure methods by increasing the mean efficiency and reducing the standard deviation (increasing uniformity) of the involved wavelengths. For a Spectralon® diffusing object, the assessed method reports a mean efficiency of 25.0% with a standard deviation of 2.9%, while simultaneous and sequential iterative exposures result in mean efficiencies of 12.1% and 20.6% with standard deviations of 3.4% and 5.4%, respectively.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Study of full-color multiplexed transmission holograms of diffusing objects recorded in photopolymer bayfol hx

  • Sevilla, M.
  • Marín-Sáez, J.
  • Chemisana, D.
  • Collados, M.V.
  • Atencia, J.
A wavelength multiplexing procedure for color transmission volume holograms of diffusing objects recorded in Bayfol® HX200 photopolymer is proposed. For the recording, three lasers of 442 nm, 532 nm and 633 nm, and a Spectralon® diffusing object were used for monochromatic and polychromatic calibration. Monochromatic calibration shows that the maximum index modulation obtained for each wavelength was not enough to give 100% efficiency, although the efficiency values achieved in the case of monochromatic recordings with diffusing objects were high, at around 90% for 633 nm and 532 nm recordings, and 60% for 442 nm. The efficiency values obtained for multiplexed holograms were 19.1% for the 442 nm hologram, 25.9% for the 532 nm hologram and 15.2% for the 633 nm.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Stacked volume holographic gratings for extending the operational wavelength range in LED and solar applications

  • Keshri, S.
  • Marín-Sáez, J.
  • Naydenova, I.
  • Murphy, K.
  • Atencia, J.
  • Chemisana, D.
  • Garner, S.
  • Collados, M.V.
  • Martin, S.
A novel stacking procedure is presented for volume phase holographic gratings (VPHGs) recorded in photopolymer material using Corning Willow Glass as a flexible substrate in order to achieve broader angular and spectral selectivity in a diffractive device with high efficiency for solar and LED applications. For the first time to our knowledge, we have shown a device designed for use with a white LED that has the same input and output angles and high efficiency when illuminated by different wavelengths. In this paper, two VPHGs were designed, experimentally recorded, and tested when illuminated at normal incidence. The experimental approach is based on stacking two individual gratings in which the spatial frequency and slant have been tailored to the target wavelength and using real-time on-Bragg monitoring of the gratings in order to control the recorded refractive index modulation, thereby optimizing each grating efficiency for its design wavelength. Lamination of the two gratings together was enabled by using a flexible glass substrate (Corning Willow Glass). Recording conditions were studied in order to minimize the change in diffraction efficiency and peak diffraction angle during lamination and bleaching. The final fabricated stacked device was illuminated by a white light source, and its output was spectrally analyzed. Compared to a single grating, the stacked device demonstrated a twofold increase in angular and wavelength range. The angular and wavelength selectivity curves are in good agreement with the theoretical prediction for this design. This approach could be used to fabricate stacked lenses for white light LED or solar applications.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Optical transmission of ferrofluids exposed to a magnetic field: Analysis by electromagnetic wave propagation numerical methods

  • Sanz-Felipe, Ángel
  • Barba, Ismael
  • Martín Alonso, Juan Carlos
Optical transmission changes in ferrofluids when exposed to magnetic fields are difficult to predict: under similar conditions, exposure to a magnetic field may cause increasing, decreasing or even non monotonous optical transmission evolution in different samples. Absence or presence of coalescence has been conjectured as the key phenomenon that causes the different behaviors, but to our knowledge without any theoretical support. In the first part of this work, experimental data are provided in order to illustrate the different possible trends that may be observed. In the second part, a set of some thousands of particles is considered in different arrangements: distributed at random, grouped in single chains or with aggregates of several chains. The optical transmission of each arrangement is obtained by means of the CST software. The numerical results obtained provide a theoretical connection between the optical transmission experimental trends observed and the processes of chain formation and aggregation by coalescence, which facilitates a much deeper understanding of the phenomena observed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Application of a paramagnetic gas theory to describe the magneto-optical response in ferrofluids

  • Sanz Felipe, Ángel
  • Martín Alonso, Juan Carlos
The magneto-optical response in ferrofluids depends significantly on the orientation and intensity of an applied magnetic field. However, such essential dependence is far from being properly described by a model based on fundamental laws. In this work, the model proposed by Elmore as an extension of the Langevin theory of a paramagnetic gas is checked. Considering the ferrofluid as an ideal paramagnetic gas is not realistic, so some modifications to the model are proposed. The modified Elmore's model adequately fits the experimental results obtained at different magnetic field intensities and orientations for the two different wavelengths used. Transmission relaxation evolution after magnetic field switch-off is also provided by the model. In addition, the results for magnetic fields parallel to the light beam are in good agreement.