Skip to main content

DESARROLLO DEL INSTRUMENTO RAMAN PARA LA MISIÓN EXOMARS DE LA ESA: FASE D2/E COORDINACION, CIENCIA DURANTE LA OPERACIÓN Y EQUIPOS SOPORTES ASOCIADOS

ESP2017-87690-C3-1-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE VALLADOLID

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

DIGITAL.INTA Repositorio Digital del Instituto Nacional de Técnica Aeroespacial
Publication Artículo científico (JournalArticle)

Evaluation of multivariate analyses and data fusion between Raman and laser‐induced breakdown spectroscopy in binary mixtures and its potential for solar system exploration

  • Manrique, J. A.
  • López Reyes, G.
  • Álvarez Pérez, A.
  • Bozic, T.
  • Veneranda, M.
  • Sanz Arranz, Aurelio
  • Saiz, J.
  • Medina García, J.
  • Rull, F.
Raman and laser‐induced breakdown spectroscopy (LIBS) spectroscopies will play an important role in planetary exploration missions in the following years, not only with Raman instruments like Raman laser spectrometer on board of Rosalid Franklin Rover or scanning habitable environments with Raman and luminescence for organics and chemicals on board Mars2020 Rover but also with combined instruments such as SuperCam. These techniques will be part of the upcoming planetary exploration missions because they can provide complementary information from the analysed sample while potentially sharing hardware components, maximizing the scientific return of the samples while limiting mass. In this framework, this study seeks to test the feasibility of combining several univariate and multivariate analysis techniques with data fusion techniques of different instruments (532 and 785 nm Raman and LIBS) to evaluate the improvements in the quantitative classification of samples in binary mixtures. We prepared two‐component mixtures that are potentially relevant in planetary exploration missions, using two different sulfates and a chloride. A more accurate classification of the samples is possible through a univariate analysis that combines the calculated concentration indicators for Raman and LIBS. On the other hand, multivariate analysis was run on Raman, LIBS, and Raman + LIBS low‐level fused data sets. The results showed a better improvement when fusing LIBS and Raman when compared with the redundant fusion but not a systematic improvement when compared with individual sets. We demonstrate that a quantification of the mineral abundances in binary mixtures can be obtained from Raman and LIBS data using univariate and multivariate analysis techniques, being the latter remarkably better, moving from performances of classification, in the whole range of concentrations, that could be over the 10% to values under 3.5%. Furthermore, the fusion of data coming from these techniques improves the classification limit with respect to the individual techniques. Thus, besides the (evident) hardware convenience of combining LIBS with 532‐nm Raman, there could be analytical advantages as well., Ministerio de Economía y Competitividad. Grant Numbers: ESP2014-56138-C3-2-R, ESP2107-87690-C3-1-R,, Peer review
DIGITAL.INTA Repositorio Digital del Instituto Nacional de Técnica Aeroespacial
Publication Artículo científico (JournalArticle)

Raman characterization of terrestrial analogs from the AMADEE‐18 astronaut simulated mission using the ExoMars RLS simulator: Implications for Mars

  • Lalla, E.
  • Konstantinidis, M.
  • López Reyes, G.
  • Daly, M. G.
  • Veneranda, M.
  • Manrique, J. A.
  • Groemer, G.
  • Vago, J. L.
  • Rull, F.
Between February 1 and February 28, 2018, the Austrian Space Forum, in cooperation with research teams from 25 nations, conducted the AMADEE‐18 mission—a human‐robotic Mars expedition simulation in the Dhofar region in the Sultanate of Oman. As a part of the AMADEE‐18 simulated Mars human exploration mission, the Remote Science Support team investigated the Dhofar area (Oman) to qualify it as a potential Mars analog site. The motivation of this research was to study and register selected samples collected by the analog astronauts during the AMADEE‐18 mission with the European Space Agency (ESA) ExoMars Raman Laser Spectrometer (RLS) simulator, compare the results with standard laboratory measurements, and establish the implication of the results to the future ESA ExoMars mission. The Raman measurements identified minerals such as carbonates (calcite and dolomite), feldspar and plagioclase (albite, anorthite, orthoclase, and sanidine), Fe‐oxides (goethite, hematite, and magnetite), and Ti‐oxide (anatase), each relevant to planetary exploration. As we have presented here, Raman spectroscopy is a powerful tool for detecting the presence of organic molecules, particularly by analyzing the principal vibration of CC and CH bonds. It has also been shown that portable Raman spectroscopy is a relevant tool for in situ field studies such as those conducted during extra‐vehicular activities (EVA) in simulated missions like the AMADEE‐18 and the future AMADEE‐2020 campaign., Ministerio de Economia y Competitividad (MINECO), Grant/Award Numbers: ESP2014-56138-C3-2-R, ESP2107-87690-C3-1-R, ESP2014-56138-C3-2-R; Canadian Space Agency; Ontario Centre of Excellence (OCE); Natural Sciences and Engineering Research Council of Canada (NSERC); With funding from the Spanish government through the "María de Maeztu Unit of Excellence" accreditation (MDM-2017-0737)., Peer review
DIGITAL.INTA Repositorio Digital del Instituto Nacional de Técnica Aeroespacial
Publication Artículo científico (JournalArticle)

ExoFiT trial at the Atacama Desert (Chile): Raman detection of biomarkers by representative prototypes of the ExoMars/Raman Laser Spectrometer

  • Veneranda, M.
  • López Reyes, G.
  • Saiz, J.
  • Manrique, J. A.
  • Sanz Arranz, Aurelio
  • Medina García, J.
  • Moral, Andoni G.
  • Seoane, Laura
  • Ibarmia, S.
  • Rull, F.
In this work, the analytical research performed by the Raman Laser Spectrometer (RLS) team during the ExoFiT trial is presented. During this test, an emulator of the Rosalind Franklin rover was remotely operated at the Atacama Desert in a Mars-like sequence of scientific operations that ended with the collection and the analysis of two drilled cores. The in-situ Raman characterization of the samples was performed through a portable technology demonstrator of RLS (RAD1 system). The results were later complemented in the laboratory using a bench top RLS operation simulator and a X-Ray diffractometer (XRD). By simulating the operational and analytical constraints of the ExoMars mission, the two RLS representative instruments effectively disclosed the mineralogical composition of the drilled cores (k-feldspar, plagioclase, quartz, muscovite and rutile as main components), reaching the detection of minor phases (e.g., additional phyllosilicate and calcite) whose concentration was below the detection limit of XRD. Furthermore, Raman systems detected many organic functional groups (–C≡N, –NH2 and C–(NO2)), suggesting the presence of nitrogen-fixing microorganisms in the samples. The Raman detection of organic material in the subsurface of a Martian analogue site presenting representative environmental conditions (high UV radiation, extreme aridity), supports the idea that the RLS could play a key role in the fulfilment of the ExoMars main mission objective: to search for signs of life on Mars., This work is financed through the European Research Council in the H2020-COMPET-2015 programme (Grant 687302) and the Ministry of Economy and Competitiveness (MINECO, Grants ESP2017-87690-C3-1-R and PID2019-107442RB-C31). The authors would also like recognize the support of the European Space Agency (ESA) and are grateful to all ExoMars team members participating in the ExoFiT trial., Peerreview
DIGITAL.INTA Repositorio Digital del Instituto Nacional de Técnica Aeroespacial
Publication Artículo científico (JournalArticle)

Raman Laser Spectrometer (RLS) calibration target design to allow onboard combined science between the RLS and MicrOmega instruments on the ExoMars rover

  • López Reyes, G.
  • Pilorget, C.
  • Moral, Andoni G.
  • Manrique, J. A.
  • Sanz Arranz, Aurelio
  • Berrocal, A.
  • Veneranda, M.
  • Rull, F.
  • Medina García, J.
  • Hamm, V.
  • Bibring, J. P.
  • Rodríguez, J. A.
  • Pérez Canora, C.
  • Mateo Marti, Eva
  • Prieto-Ballesteros, Olga
  • Lalla, E.
  • Vago, J. L.
The ExoMars rover, scheduled to be launched in 2020, will be equipped with a novel and diverse payload. It will also include a drill to collect subsurface samples (from 0‐ to 2‐m depth) and deliver them to the rover analytical laboratory, where it will be possible to perform combined science between instruments. For the first time, the exact same sample target areas will be investigated using complementary analytical methods—infrared spectrometry, Raman spectrometry, and laser desorption mass spectrometry—to establish mineralogical and organic chemistry composition. Fundamental for implementing this cooperative science strategy is the Raman Laser Spectrometer (RLS) calibration target (CT). The RLS CT features a polyethylene terephthalate disk used for RLS calibration and verification of the instrument during the mission. In addition, special patterns have been recorded on the RLS CT disk that the other instruments can detect and employ to determine their relative position. In this manner, the RLS CT ensures the spatial correlation between the three analytical laboratory instruments: MicrOmega, RLS, and MOMA. The RLS CT has been subjected to a series of tests to qualify it for space utilization and to characterize its behavior during the mission. The results from the joint work performed by the RLS and MicrOmega instrument teams confirm the feasibility of the “combined science” approach envisioned for ExoMars rover operations, whose science return is optimized when complementing the RLS and MicrOmega joint analysis with the autonomous RLS operation., Spanish Ministerio de Economia y Competitividad, Grant/Award Numbers: ESP2014-56138-C3-2-R, ESP2107-87690-C3-1-R; With funding from the Spanish government through the "María de Maeztu Unit of Excellence" accreditation (MDM-2017-0737)., Peer review
DIGITAL.INTA Repositorio Digital del Instituto Nacional de Técnica Aeroespacial
Publication Artículo científico (JournalArticle)

Raman spectroscopy and planetary exploration: Testing the ExoMars/RLS system at the Tabernas Desert (Spain)

  • Veneranda, M.
  • López Reyes, G.
  • Manrique, J. A.
  • Sanz Arranz, Aurelio
  • Medina García, J.
  • Pérez, Carlos
  • Quintana, C.
  • Moral, Andoni G.
  • Rodríguez, J. A.
  • Zafra, Jesús
  • Nieto Calzada, L. M.
  • Rull, F.
Highlights The ExoMars mission to Mars was simulated at the Tabernas Desert (ExoFiT trials) Raman spectrometers were used the laboratory to analyse the drilled cores. The main mineralogical phases were successfully detected in-situ by the RLS EQM-2. The RLS ExoMars simulator detected additional minerals and organic compounds. The suitability of Raman spectroscopy for space exploration missions was disclosed., ExoFit trials are field campaigns financed by ESA to test the Rosalind Franklin rover and to enhance collaboration practices between ExoMars working groups. During the first trial, a replicate of the ExoMars rover was remotely operated from Oxfordshire (United Kingdom) to perform a complex sequence of scientific operation at the Tabernas Desert (Spain). By following the ExoMars Reference Surface Mission (RSM), the rover investigated the Badlands subsoil and collected drill cores, whose analytical study was entrusted to the RLS (Raman Laser Spectrometer) team. The preliminary characterization of core samples was performed in situ through the RLS Engineering and Qualification Model (EQM-2) and the Raman Demonstrator (RAD1), being this a new, portable emulator of the RLS. In situ results where then complemented by laboratory analysis using the RLS ExoMars simulator and the commercial version of the Curiosity/CheMin XRD system. Raman data, obtained by closely simulating the operational constraints of the mission, successfully disclosed the mineralogical composition of the samples, reaching the detection of minor/trace phases that were not detected by XRD. More importantly, Raman analysis detected many vibrational peaks potentially emitted by organic functional groups, thus suggesting the presence of microorganisms in the arid sub-surface of the Tabernas Desert. In light of the forthcoming ExoMars mission, the results here presented proves that RLS could play a critical role in the characterization of Martian sub-surface environments and in the analytical detection of potential traces of live., This work is financed through the European Research Council in the H2020-COMPET-2015 programme (grant 687302) and the Ministry of Economy and Competitiveness (MINECO, grants ESP2017-87690-C3-1-R and PID2019-107442RB-C31)., Peerreview
DIGITAL.INTA Repositorio Digital del Instituto Nacional de Técnica Aeroespacial
Publication Artículo científico (JournalArticle)

SuperCam Calibration Targets: Design and Development

  • Manrique, J. A.
  • López Reyes, G.
  • Cousin, Agnes
  • Rull, F.
  • Maurice, Sylvestre
  • Wiens, Roger
  • Madariaga, M. B.
  • Gasnault, O.
  • Aramendia, J.
  • Arana, G.
  • Beck, P.
  • Bernard, S.
  • Bernardi, P.
  • Bernt, M. H.
  • Berrocal, A.
  • Beyssac, O.
  • Caïs, P.
  • Castro, K.
  • Clegg, S. M.
  • Cloutis, E.
  • Dromart, G.
  • Drouet, C.
  • Dubois, B.
  • Escribano, D.
  • Fabre, C.
  • Fernández, A.
  • Forni, Olivier
  • García Baonza, V.
  • Gontijo, I.
  • Johnson, J. R.
  • Laserna, Javier
  • Lasue, J.
  • Madsen, Soren N.
  • Mateo Marti, Eva
  • Medina García, J.
  • Meslin, P.
  • Montagnac, G.
  • Moros, J.
  • Ollila, A. M.
  • Ortega, Cristina
  • Prieto-Ballesteros, Olga
  • Reess, J. M.
  • Robinson, S.
  • Rodríguez, Joseph
  • Saiz, J.
  • Sanz Arranz, Aurelio
  • Sard, I.
  • Sautter, V.
  • Sobron, P.
  • Toplis, M.
  • Veneranda, M.
Part of a collection: The Mars 2020 Mission, SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system., The authors would like to thank the Spanish MINECO, projects ESP2014-56138-C3-1-R, ESP2055-71965-REDT, ESP2017-87690-C3-1-R, and RED2018-102600-T for funding. Additional funding in Spain was provided by the University of Valladolid and the local and regional institutions as Valladolid City Council, Valladolid Provincial Council, Junta de Castilla y Leon and we are grateful for their support. Support in the US was provided by NASA’s Mars Exploration Program. Support in France was provided by CNES, CNRS, and local Universities. The Valladolid team thanks in particular the RLS team from INTA and the University of Valladolid for their strong support in many phases of this exciting project. The Danish contribution was funded through support by the Carlsberg Foundation, grants CF16-0981 and CF17-0979 and in addition, we are grateful to DuPont Electronic Materials for providing the Kapton® foils used for reducing the transfer of shock energy to the permanent magnets used for color references. In Canada, funding was provided by the Canadian Space Agency, NSERC, CFI, MRIF, and U. Winnipeg., Peer review
DIGITAL.INTA Repositorio Digital del Instituto Nacional de Técnica Aeroespacial
Publication Artículo científico (JournalArticle)

ExoMars Raman Laser Spectrometer: A Tool for the Potential Recognition of Wet-Target Craters on Mars

  • Veneranda, M.
  • López Reyes, G.
  • Manrique, J. A.
  • Medina García, J.
  • Ruiz Galende, P.
  • Torre Fdez, I.
  • Castro, K.
  • Lantz, C.
  • Poulet, F.
  • Dypvik, H.
  • Werner, S. C.
  • Rull, F.
In the present work, near-infrared, laser-induced breakdown spectroscopy, Raman, and X-ray diffractometer techniques have been complementarily used to carry out a comprehensive characterization of a terrestrial analogue selected from the Chesapeake Bay impact structure (CBIS). The obtained data clearly highlight the key role of Raman spectroscopy in the detection of minor and trace compounds, through which inferences about geological processes occurred in the CBIS can be extrapolated. Beside the use of commercial systems, further Raman analyses were performed by the Raman laser spectrometer (RLS) ExoMars Simulator. This instrument represents the most reliable tool to effectively predict the scientific capabilities of the ExoMars/Raman system that will be deployed on Mars in 2021. By emulating the analytical procedures and operational restrictions established by the ExoMars mission rover design, it was proved that the RLS ExoMars Simulator can detect the amorphization of quartz, which constitutes an analytical clue of the impact origin of craters. Beside amorphized minerals, the detection of barite and siderite, compounds crystallizing under hydrothermal conditions, helps indirectly to confirm the presence of water in impact targets. Furthermore, the RLS ExoMars Simulator capability of performing smart molecular mappings was successfully evaluated., This project is financed through the European Research Council in the H2020-COMPET-2015 programme (grant 687302) and the Ministry of Economy and Competitiveness (grants ESP2014-56138-C3-2-R and ESP2017-87690-C3-1-R); With funding from the Spanish government through the "María de Maeztu Unit of Excellence" accreditation (MDM-2017-0737), Peer review
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

The relevance of the creation of a raman and nir spectroscopic database for the upcoming Mars missions

  • Baonza, Valentín G.
Trabajo presentado en 49th Lunar and Planetary Science Conference, celebrada en The Woodlands, Texas (Estados Unidos), del 19 al 23 de marzo de 2018, The planetary exploration of the Solar System has increased during the last years, specially the Martian one. The next missions of ESA and NASA (Exomars2020 and Mars2020, respectively) are aimed at the exploration of the surface of Mars with a rover. Spectroscopic equipments are one of the main analytical instruments that the rover of both missions carry, due to the advantages that this kind of techniques offer for the Martian missions [1, 2]. Thus, the creation of a mineral spectroscopic database is mandatory improving and extending the current ones. With this pourpose, in this work different mineral groups were analysed by means of Raman spectroscopy and visible-near infrared (VNIR) spectroscopy, as they are two techniques that rovers of both missions will use., This work has been financially supported through the Exomars-Raman project (ref. ESP2017-87690-C3-1-R), funded by the Spanish MINECO and the European Regional Development Fund. Moreover, we would like to thank to the Geominery Museum of the Spanish Geological and Miner Institute (IGME) and specially to Rafael Lozano and Ruth González Laguna for allowing the access to the minerals and for all the help provided, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Homogeneity assessment of the SuperCam calibration targets onboard rover perseverance

  • Baonza, Valentín G.
  • Martínez-Frías, J.
The SuperCam instrument, onboard the Perseverance rover (Mars 2020 mission) is designed to perform remote analysis on the Martian surface employing several spectroscopic techniques such as Laser Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman (TRR), Time-Resolved Fluorescence (TRF) and Visible and Infrared (VISIR) reflectance. In addition, SuperCam also acquires high-resolution images using a color remote micro-imager (RMI) as well as sounds with its microphone. SuperCam has three main subsystems, the Mast Unit (MU) where the laser for chemical analysis and collection optics are housed, the Body Unit (BU) where the different spectrometers are located inside the rover, and the SuperCam Calibration Target (SCCT) located on the rover's deck to facilitate calibration tests at similar ambient conditions as the analyzed samples. To perform adequate calibrations on Mars, the 22 mineral samples included in the complex SCCT assembly must have a very homogeneous distribution of major and minor elements. The analysis and verification of such homogeneity for the 5¿6 replicates of the samples included in the SCCT has been the aim of this work. To verify the physic-chemical homogeneity of the calibration targets, micro Energy Dispersive X-ray Fluorescence (EDXRF) imaging was first used on the whole surface of the targets, then the relative abundances of the detected elements were computed on 20 randomly distributed areas of 100 × 100 ¿m. For those targets showing a positive Raman response, micro-Raman spectroscopy imaging was performed on the whole surface of the targets at a resolution of 100 × 100 ¿m. The %RSD values (percent of relative standard deviation of mean values) for the major elements measured with EDXRF were compared with similar values obtained by two independent LIBS set-ups at spot sizes of 300 ¿m in diameter. The statistical analysis showed which elements were homogeneously distributed in the 22 mineral targets of the SCCT, providing their uncertainty values for further calibration. Moreover, nine of the 22 targets showed a good Raman response and their mineral distributions were also studied. Those targets can be also used for calibration purposes of the Raman part of SuperCam using the wavenumbers of their main Raman bands proposed in this work.