Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Unipolar Electrogram Eigenvalue Distribution Analysis for the Identification of Atrial Fibrosis

  • Riccio, Jennifer
  • Rocher-Ventura, Sara
  • Martínez-Mateu, Laura
  • Alcaine, Alejandro
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Atrial fibrosis plays an important role in the pathogenesis of atrial fibrillation (AF). Low bipolar electrograms (b-EGMs) peak-to-peak voltage areas indicate scar tissue and are considered targets for AF substrate ablation. However, this approach ignores the spatiotemporal information embedded in the signal and the dependence of b-EGMs on catheter orientation. This work proposes an approach to detect fibrosis based on the eigenvalue dominance ratio (EIGDR) in an ensemble (clique) of unipolar electrograms (u-EGMs). A 2-D tissue with a central circular patch of fibrosis has been simulated using the Courtemanche cellular model. Maps of EIGDR have been computed using two sizes of electrode cliques, from the original u-EGMs within the ensemble or after a time alignment of these signals. Performance of each map in detecting fibrosis has been evaluated using receiver operating characteristic curves and detection accuracy. Best results achieve an area under the curve (AUC) of 0.98 and an accuracy (ACC) of 1 when we use as marker the gain in eigenvalue dominance produced by the ensemble alignment, Funding comes from EU Programme H2020 under the Marie Sklodowska-Curie Grant No 766082 (MY-ATRIA), Gobierno de Aragon (BSICoS Group T39-20R) cofunded by FEDER 2014-2020 "Building Europe from Aragon", fellowship ACIF/2018/174 from Generalitat Valenciana, and PID2019-104881RB-I00 from MICINN, Spain
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Omnipolar EGM Voltage Mapping for Atrial Fibrosis Identification Evaluated with an Electrophysiological Model

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher-Ventura, Sara
  • Laguna, Pablo
  • Martínez, Juan Pablo
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Atrial fibrillation (AF) is the most spread heart arrhythmia, whose mechanisms are not completely clear yet. Catheter ablation is a standard treatment, which isolates the area involved in the arrhythmia. Intracardiac electrograms (EGMs) are used to better understand the AF mechanisms and to find appropriate ablation sites. Bipolar EGMs (b-EGMs) are often employed, but their amplitude and shape depend on catheter orientation, limiting reliability. To avoid this uncertainty, an approach insensitive to catheter orientation, referred as Omnipolar EGM (OP-EGM) method, has been introduced, which uses an estimation of the electric field within a group of electrodes, referred as clique. In this work, we compare different mapping approaches based on b-EGMs and OPEGM signals in simulation including fibrosis, so to evaluate their ability to detect fibrosis and reproduce the spatial distribution of the voltage. Maps have been computed using two clique configurations (square and triangular), introducing or not a previous time alignment of the bEGMs. OP-EGM signals have been obtained by projecting the electric field along directions of its maximal excursion and its principal components. Results show that both cliques configurations present good performance, in terms of fibrosis detection and correlation with the reference voltage maps. In addition, the proposed alignment of b-EGMS improves maps based on OP-EGM signals, especially when square cliques are used., This work is part of a project that has received funding from the European Union¿s Horizon 2020 research and innovation program under the Marie Sk¿odowska-Curie grant agreement No 766082 (MY-ATRIA).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Changes in QRS and T-wave Loops Subsequent to an Increase in Left Ventricle Globularity as in Intrauterine Growth Restriction: a Simulation Study

  • Bueno-Palomeque, Freddy L
  • Mountris, Konstantinos A
  • Mincholé, Ana
  • Bailón, Raquel
  • Pueyo, Esther
  • Laguna, Pablo
  • Ortigosa, Nuria|||0000-0002-5272-7661
[EN] Cardiovascular remodeling induced by intrauterine growth restriction manifests in adulthood by more globular ventricles, as evidenced by in vivo measurements. The angle between the dominant vectors of the QRS and T-wave loops has been reported to be significantly altered as a result of the induced remodeling. To investigate whether the more globular ventricular shape was a major factor contributing to such alteration, we performed electrophysiological simulations in a human biventricular model for control and in a model obtained by deforming the control one to represent a more spherical left ventricle (SLV). Transmural ventricular heterogeneities and a Purkinje network were included. 12-lead ECGs were calculated, from which spatial QRS and T-wave angles were computed. The angle between the T-wave and the XZ-plane was found to increase in the SLV model, showing a variation similar to that reported in in vivo studies. However, the angle between the dominant vectors of the QRS and T-wave loops projected onto the XY-plane was lower for control, contrary to clinical observations in IUGR adults. Other clinical results could not be reproduced in our simulations either. Our findings suggest that a more globular left ventricular shape leads to changes in the angles of QRS and T-wave loops, but further research is needed to fully understand these changes and the underlying mechanisms, I would like to acknowledge support by Fundaci ' on Carolina, Universidad de Zaragoza and Universidad Polit ' ecnica Salesiana through its doctoral scholar-ship. This work was supported by projects ERC-StG 638284 (ERC), PID2019-105674RB-I00 and PID2019104881RB-I00 (MICINN) and LMP124-18 and reference group T39-20R (Arag ' on Government cofunded by FEDER 2014-2020 "Building Europe from Aragon"). Computations were performed using ICTS NANBIOSIS (HPC unit at U. Zaragoza). N. Ortigosa acknowledges support from Generalitat Valenciana under grant Prometeo/2017/102 and Spanish MINECO under grant MTM2016-76647-P
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Cardiovascular Changes Induced by Acute Emotional Stress Estimated from the Pulse Transit Time Difference

  • Armañac, P.
  • Kontaxis, P.
  • Lázaro, J.
  • Laguna, P.
  • Bailón, R.
  • Gil, E.
In the present work, the difference between arrival times of photoplethysmographic (PPG) pulses from two different sites of the arterial tree (PTTD) is calculated. As the PTTD is considered to be related with arterial pulse wave velocity, an evaluation of it''s usefulness to identify states of acute mental stress is performed. A subset of fourteen healthy volunteers undergoing a stress protocol was analysed and a statistical test was carried out to evaluate the validity of the proposed method. The results showed that the standard deviation of the PTTD had sufficient statistical capacity to discern between states of stress and relaxation. Furthermore, a generalised descending trend of the mean PTTD can be seen from relaxation to stress.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

SK Channel Block and Adrenergic Stimulation Counteract Acetylcholine-Induced Arrhythmogenic Effects in Human Atria

  • Celotto, Chiara
  • Sánchez, Carlos
  • Mountris, Konstantinos A.
  • Laguna, Pablo
  • Pueyo, Esther
There is increasing evidence on the role of the autonomic nervous system in the pathogenesis of atrial fibrillation. Interventions targeting autonomic modulation of atrial electrical activity have been shown to reduce the incidence of atrial arrhythmias. Additionally, recent investigations have proved that pharmacological therapies inhibiting small-conductance calcium-activated potassium (SK) channels are able to lessen cholinergic effects in the atria.In this study we use computational modeling and simulation to test individual and combined effects of SK channel block and adrenergic stimulation in counteracting detrimental effects induced by the parasympathetic neurotransmitter acetylcholine (ACh) on human atrial electrophysiology. Cell and tissue models are built that incorporate descriptions of SK channels as well as of isoproterenol (Iso)- and ACh-mediated regulation of the atrial action potential (AP). Three different cellular AP models, representing a range of physiological AP shapes, are considered and both homogeneous and heterogeneous ACh distributions in atrial tissue are simulated.At the cellular level, SK channel block is demonstrated to partially revert shortening of AP duration (APD) mediated by ACh at various doses, whereas 1 µM Iso has a variable response depending on the AP shape. The combination of SK block and Iso is in all cases able to take APD back to baseline levels, recovering between 82% and 120% of the APD shortening induced by 0.1 µM ACh. At the tissue level, SK block and Iso alone or in combination do not exert remarkable effects on conduction velocity, but the combination of the two is able to notably prolong the ACh-mediated APD shortening, thus increasing the wavelength for reentry.In conclusion, the results from this study support the combination of SK channel block and adrenergic stimulation as a potential option to counteract parasympathetically-mediated proarrhythmic effects in the human atria.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Improving signal stability in a multi-electrode array (MEA) system for cardiac biopsies

  • Velarte, A.
  • Otín, A.
  • Pueyo, E.
  • Guimera, A.
  • Villa, R.
This work evaluates the performance of a microelectrode array (MEA) to be used in a specific platform dedicated for measuring field potentials of small human cardiac samples. A test bench has been developed to characterize the electrodes by measuring their impedance as well as to modify their characteristic curve using a replatinization process, where black platinum is deposited on the indicated areas of the MEA flex-pcb. This set-up consists of the array of microelectrodes made of gold, together with its corresponding electronic adapter board, a potentiostat and an electrochemical interface. Phosphate buffered saline (PBS), which is commonly considered for this type of analysis, has been used for impedance characterization. Initially, the impedance presents a highly variable behavior at different frequencies as well as between the different channels of the array. Once the platinization process has been carried out, the impedance in all the recording channels is very similar and has decreased over a large part of the frequency range under study. A complete electrical model of the electrodes has been proposed and analyzed, achieving better results by including the mathematical constant phase element (CPE) associated with capacitive behavior (model fitting error < 2%). Finally, the characterization of the different noise contributions has been carried out. Based on the obtained results, it can be concluded that the evaluated system allows the recording of field potential signals from small human cardiac tissues.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Right ventricular vs left bundle branch pacing-induced changes in ECG depolarization and repolarization

  • Sales Bellés, Clara
  • Palacios, Saúl
  • Melero, Jorge
  • Julián, Inés
  • Ramos, Javier
  • Pablo Martínez, Juan
  • Minchole, Ana
  • Pueyo, Esther
Patients suffering from bradycardia are indicated for pacemaker implantation. Right ventricular pacing (RVP)has been conventionally used for this purpose, but it can increase the risk of atrial fibrillation and heart failure. Left bundle branch area pacing (LBBAP) has been proposed as a new physiological pacing technique. The aim of this study was to compare changes induced by RVP and LBBAP in the ECG. 10-minute 12-lead ECG recordings were acquired at baseline and after pacemaker implantation from 83 patients (31 RVP, 52 LBBAP). Median beats were calculated for each patient at baseline and post-implantation states. ECG markers including QRS duration (dQRS)and area (aQRS) and heart rate-corrected QT (QTc) and Tpeak-to-Tend (Tpec) intervals were measured. dQRS and aQRS decreased significantly at post-implantation with respect to baseline, both being significantly lower for LBBAP than RVP after pacemaker implantation. QTc was significantly reduced at post-implantation for both pacing techniques with no differences between them. Tpec did not change either between states or techniques. In conclusion, LBBAP led to more synchronized ventricular depolarization, supporting potentially improved clinical outcomes with LBBAP as compared to RVP for anti-bradycardia therapy
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Changes in T-peak-to-T-end Morphology Measured by Time-Warping Are Associated with Ischemia-Induced Ventricular Fibrillation in a Porcine Model

  • Gómez Fonseca, Neurys
  • Ramírez, Julia
  • Martin-Yebra, Alba
  • M. Demidova, Marina
  • Platonov, Pyotr
  • Martínez, Juan Pablo
  • Laguna, Pablo
In this work, we use a time-warping-based morphology variation index, dw , computed between the peak and the end of the T-wave, and assess its association with the occurrence of ventricular fibrillation (VF) episodes in ischemic conditions. ECG recordings from 26 pigs under- going a 40-minute coronary occlusion were analyzed. The dw series was obtained by quantifying the morphological differences between the final part of the T wave at different stages of the occlusion and a reference T wave in the control recording. During control recordings, dw remained stationary with a median value along each recording of 1.76 ms, IQR of 1.80, while during artery occlusion followed a well-marked gradual increasing trend as ischemia progressed, with median of 15.47 ms, IQR of 18.53. At the 20-to-25 min period from occlusion onset (and during 5 min prior to VF episode) d w averages in the VF group was significantly higher than in the non-VF group with median values of 40.0 (and 34.4) vs 7.8 (and 7.7) ms, with p-values of 0.002 (and 0.001), respectively. In conclusion, dynamic increases of the dw index during ischaemia progression in pigs are associated with VF occurrence.