Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 171
Encontrada(s) 2 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Unipolar Electrogram Eigenvalue Distribution Analysis for the Identification of Atrial Fibrosis

  • Riccio, Jennifer
  • Rocher-Ventura, Sara
  • Martínez-Mateu, Laura
  • Alcaine, Alejandro
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Atrial fibrosis plays an important role in the pathogenesis of atrial fibrillation (AF). Low bipolar electrograms (b-EGMs) peak-to-peak voltage areas indicate scar tissue and are considered targets for AF substrate ablation. However, this approach ignores the spatiotemporal information embedded in the signal and the dependence of b-EGMs on catheter orientation. This work proposes an approach to detect fibrosis based on the eigenvalue dominance ratio (EIGDR) in an ensemble (clique) of unipolar electrograms (u-EGMs). A 2-D tissue with a central circular patch of fibrosis has been simulated using the Courtemanche cellular model. Maps of EIGDR have been computed using two sizes of electrode cliques, from the original u-EGMs within the ensemble or after a time alignment of these signals. Performance of each map in detecting fibrosis has been evaluated using receiver operating characteristic curves and detection accuracy. Best results achieve an area under the curve (AUC) of 0.98 and an accuracy (ACC) of 1 when we use as marker the gain in eigenvalue dominance produced by the ensemble alignment, Funding comes from EU Programme H2020 under the Marie Sklodowska-Curie Grant No 766082 (MY-ATRIA), Gobierno de Aragon (BSICoS Group T39-20R) cofunded by FEDER 2014-2020 "Building Europe from Aragon", fellowship ACIF/2018/174 from Generalitat Valenciana, and PID2019-104881RB-I00 from MICINN, Spain
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Atrial fibrosis identification with unipolar electrogram eigenvalue distribution analysis in multi-electrode arrays

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher, Sara
  • Martínez-Mateu, Laura
  • Invers-Rubio, Eric
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Atrial fibrosis plays a key role in the initiation and progression of atrial fibrillation (AF). Atrial fibrosis is typically identified by a peak-to-peak amplitude of bipolar electrograms (b-EGMs) lower than 0.5 mV, which may be considered as ablation targets. Nevertheless, this approach disregards signal spatiotemporal information and b-EGM sensitivity to catheter orientation. To overcome these limitations, we propose the dominant-to-remaining eigenvalue dominance ratio (EIGDR) of unipolar electrograms (u-EGMs) within neighbor electrode cliques as a waveform dispersion measure, hypothesizing that it is correlated with the presence of fibrosis. A simulated 2D tissue with a fibrosis patch was used for validation. We computed EIGDR maps from both original and time-aligned u-EGMs, denoted as R and R-A, respectively, also mapping the gain in eigenvalue concentration obtained by the alignment, Delta R-A. The performance of each map in detecting fibrosis was evaluated in scenarios including noise and variable electrode-tissue distance. Best results were achieved by R-A, reaching 94% detection accuracy, versus the 86% of b-EGMs voltage maps. The proposed strategy was also tested in real u-EGMs from fibrotic and non- fibrotic areas over 3D electroanatomical maps, supporting the ability of the EIGDRs as fibrosis markers, encouraging further studies to confirm their translation to clinical settings., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work was supported by European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 766082 and No. 860974, by projects PID2019-105674RBI00, PID2019-104881RB-I00 (MICINN) and Aragon Government (Reference Group Biomedical Signal Interpretation and Computational Simulation (BSICoS) T39-20R) cofunded by FEDER 20142020 "Building Europe from Aragon", by fellowship ACIF/2018/174 and Grant PROMETEO/2020/043, both from Direccion General de Politica Cientifica de la Generalitat Valenciana, and by DENIS Project (Volunteer Computer platform) supported through CoMBA 2021-2022 internal projects call from Universidad San Jorge.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Omnipolar EGM Voltage Mapping for Atrial Fibrosis Identification Evaluated with an Electrophysiological Model

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher-Ventura, Sara
  • Laguna, Pablo
  • Martínez, Juan Pablo
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Atrial fibrillation (AF) is the most spread heart arrhythmia, whose mechanisms are not completely clear yet. Catheter ablation is a standard treatment, which isolates the area involved in the arrhythmia. Intracardiac electrograms (EGMs) are used to better understand the AF mechanisms and to find appropriate ablation sites. Bipolar EGMs (b-EGMs) are often employed, but their amplitude and shape depend on catheter orientation, limiting reliability. To avoid this uncertainty, an approach insensitive to catheter orientation, referred as Omnipolar EGM (OP-EGM) method, has been introduced, which uses an estimation of the electric field within a group of electrodes, referred as clique. In this work, we compare different mapping approaches based on b-EGMs and OPEGM signals in simulation including fibrosis, so to evaluate their ability to detect fibrosis and reproduce the spatial distribution of the voltage. Maps have been computed using two clique configurations (square and triangular), introducing or not a previous time alignment of the bEGMs. OP-EGM signals have been obtained by projecting the electric field along directions of its maximal excursion and its principal components. Results show that both cliques configurations present good performance, in terms of fibrosis detection and correlation with the reference voltage maps. In addition, the proposed alignment of b-EGMS improves maps based on OP-EGM signals, especially when square cliques are used., This work is part of a project that has received funding from the European Union¿s Horizon 2020 research and innovation program under the Marie Sk¿odowska-Curie grant agreement No 766082 (MY-ATRIA).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Changes in QRS and T-wave Loops Subsequent to an Increase in Left Ventricle Globularity as in Intrauterine Growth Restriction: a Simulation Study

  • Bueno-Palomeque, Freddy L
  • Mountris, Konstantinos A
  • Mincholé, Ana
  • Bailón, Raquel
  • Pueyo, Esther
  • Laguna, Pablo
  • Ortigosa, Nuria|||0000-0002-5272-7661
[EN] Cardiovascular remodeling induced by intrauterine growth restriction manifests in adulthood by more globular ventricles, as evidenced by in vivo measurements. The angle between the dominant vectors of the QRS and T-wave loops has been reported to be significantly altered as a result of the induced remodeling. To investigate whether the more globular ventricular shape was a major factor contributing to such alteration, we performed electrophysiological simulations in a human biventricular model for control and in a model obtained by deforming the control one to represent a more spherical left ventricle (SLV). Transmural ventricular heterogeneities and a Purkinje network were included. 12-lead ECGs were calculated, from which spatial QRS and T-wave angles were computed. The angle between the T-wave and the XZ-plane was found to increase in the SLV model, showing a variation similar to that reported in in vivo studies. However, the angle between the dominant vectors of the QRS and T-wave loops projected onto the XY-plane was lower for control, contrary to clinical observations in IUGR adults. Other clinical results could not be reproduced in our simulations either. Our findings suggest that a more globular left ventricular shape leads to changes in the angles of QRS and T-wave loops, but further research is needed to fully understand these changes and the underlying mechanisms, I would like to acknowledge support by Fundaci ' on Carolina, Universidad de Zaragoza and Universidad Polit ' ecnica Salesiana through its doctoral scholar-ship. This work was supported by projects ERC-StG 638284 (ERC), PID2019-105674RB-I00 and PID2019104881RB-I00 (MICINN) and LMP124-18 and reference group T39-20R (Arag ' on Government cofunded by FEDER 2014-2020 "Building Europe from Aragon"). Computations were performed using ICTS NANBIOSIS (HPC unit at U. Zaragoza). N. Ortigosa acknowledges support from Generalitat Valenciana under grant Prometeo/2017/102 and Spanish MINECO under grant MTM2016-76647-P
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Analysis of split-spectrum algorithms in an automatic detection framework

  • Rodríguez Martínez, Alberto
  • Salazar Afanador, Addisson|||0000-0001-5849-5104
  • Vergara Domínguez, Luís|||0000-0001-6803-4774
In this paper we study the problem of automatic detection of ultrasonic echo pulses in a grain noise background considering split-spectrum (SS) algorithms as sub-optimum solutions. First, SS algorithms are reformulated following an algebraic approach which is more appropriate from the perspective of automatic detection. Then, recombination methods will be modified according to the previous reformulation. We will consider some of the popular methods based in the phase observation (Polarity Thresholding and Scaled Polarity Thresholding) and in the order statistics (Minimization, Normalized Minimization and Frequency Multiplication). Different experiments with simulated and real data will support our theoretical analysis, and will show the advantages of the Frequency Multiplication method. Derivation of the formulas of the probability of detection and the probability of false alarm in every detector are included in the paper. (C) 2012 Elsevier B.V. All rights reserved., This work has been supported by the Ministerio de Fomento (Spain), the Ministerio de Ciencia e Innovacion (Spain) and FEDER funds under the projects T39/2006, TEC2008-06728. Also partially funded by Generalitat Valenciana (Spain) under program PROMETEO 2010/040.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

QRS-T Angles as Markers for Heart Sphericity in Subjects With Intrauterine Growth Restriction: A Simulation Study

  • Bueno-Palomeque, Freddy L.
  • Mountris, Konstantinos A.
  • Bailón, Raquel
  • Bijnens, Bart
  • Crispi, Fátima
  • Pueyo, Esther
  • Mincholé, Ana
  • Laguna, Pablo
  • Ortigosa, Nuria|||0000-0002-5272-7661
[EN] Changes induced by intrauterine growth restriction (IUGR) in cardiovascular anatomy and function that persist throughout life have been associated with a higher predisposition to heart disease in adulthood. Together with cardiac morphological remodelling, evaluated through the ventricular sphericity index, alterations in cardiac electrical function have been reported by characterization of the depolarization and repolarization loops, and their angular relationship, measured from the vectorcardiogram. The underlying relationship between the morphological remodelling and the angular variation of QRS and T-wave dominant vectors, if any, has not been explored. The aim of this study was to evaluate this relationship using computational models based on realistic heart and torso in which IUGR-induced morphological changes were incorporated by reducing the ventricular sphericity index. Specifically, we departed from a control model and we built eight different globular heart models by reducing the base-to-apex length and enlarging the basal ventricular diameter. We computed QRS and T-wave dominant vectors and angles from simulated pseudo-electrocardiograms and we compared them with clinical measurements. Results for the QRS to T angles follow a change trend congruent with that reported in clinical data, supporting the hypothesis that the IUGR-induced morphological remodelling could contribute to explain the observed angle changes in IUGR patients. By additionally varying the position of the ventricles with respect to the torso and the electrodes, we found that electrode displacement can impact the quantified angles and should be considered when interpreting the results., This work was supported in part by Fundacion Carolina and Universidad Politenica Salesiana, in part by the Spanish Ministry of Science and Innovation (MICINN) and FEDER Una manera de hacer Europa under Grants PID2019-105674RB-I00, PID2021-128972OA-I00, TED2021-130459B-I00, and PID2020-119457GB-100, through Ramon y Cajal Program under Grant RYC2019-027420-I, in part by the Gobierno de Aragon, Reference Group BSICoS T39-20R, and in part by Project LMP94_21.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

New analysis and extensions of split-spectrum processing algorithms

  • Rodríguez, A.
  • Miralles Ricós, Ramón|||0000-0003-0039-2553
  • Bosch Roig, Ignacio|||0000-0003-3190-3635
  • Vergara Domínguez, Luís|||0000-0001-6803-4774
[EN] In this paper we compare the performances of different variants of split-spectrum algorithms and propose some new extensions based on the use of variable bandwidth filters equally spaced in frequency and energy gain equalized. Signal-to-Noise Ratio Gain and Flaw-to-Clutter Ratio Gain factors were selected as the figures of merit to make the comparisons among the different methods. We considered simulated ultrasonic signals using both stationary and non-stationary models for the grain noise, and real scans obtained in laboratory from low dispersive (aluminum) and high dispersive (cement) materials. Frequency Multiplication (FM) recombination method is revealed as the best option when combined with the new extensions., This work has been supported by the Ministerio de Fomento (Spain) and the Ministerio de Ciencia e Innovacion (Spain), and FEDER funds under the projects T39/2006, TEC2008-06728 and TEC2008-02975
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Sustainable supply chain management: The influence of disposal scenarios on the environmental impact of a 2400 L waste container

  • Galve, José Eduardo
  • Elduque, Daniel
  • Pina, Carmelo
  • Javierre, Carlos
This paper analyzes the influence of the supply chain management on the environmental impact of a 2400 L waste disposal container used in most cities of Spain. The studied functional unit, a waste disposal container, made up mostly of plastic materials and a metallic structure, and manufactured in Madrid (Spain), is distributed to several cities at an average distance of 392 km. A life cycle assessment of four different scenarios (SC) has been calculated with the software EcoTool v4.0 (version 4.0; i+: Zaragoza, Spain, 2015) and using Ecoinvent v3.0 database (version 3.0; Swiss Centre for Life Cycle Inventories: St. Gallen, Switzerland, 2013). The environmental impact has been characterized with two different methodologies, recipe and carbon footprint. In order to reduce the environmental impact, several end of life scenarios have been performed, analyzing the influence of the supply chain on a closed-looped system that increases recycling. Closed loop management of the waste and reuse of parts allows companies to stop selling products and start selling the service that their products give to the consumers.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Influence of composition on the environmental impact of a cast aluminum alloy

  • Gómez, Patricia
  • Elduque, Daniel
  • Sarasa, Judith
  • Pina, Carmelo
  • Javierre, Carlos
The influence of alloy composition on the environmental impact of the production of six aluminum casting alloys (Al Si12Cu1(Fe), Al Si5Mg, Al Si9Cu3Zn3Fe, Al Si10Mg(Fe), Al Si9Cu3(Fe)(Zn) and Al Si9) has been analyzed. In order to perform a more precise environmental impact calculation, Life Cycle Assessment (LCA) with ReCiPe Endpoint methodology has been used, with the EcoInvent v3 AlMg3 aluminum alloy dataset as a reference. This dataset has been updated with the material composition ranges of the mentioned alloys. The balanced, maximum and minimum environmental impact values have been obtained. In general, the overall impact of the studied aluminum alloys varies from 5.98 ˆ 10 ´1 pts to 1.09 pts per kg, depending on the alloy composition. In the analysis of maximum and minimum environmental impact, the alloy that has the highest uncertainty is AlSi9Cu3(Fe)(Zn), with a range of ¿9%. The elements that contribute the most to increase its impact are Copper and Tin. The environmental impact of a specific case, an LED luminaire housing made out of an Al Si12Cu1(Fe) cast alloy, has been studied, showing the importance of considering the composition. Significant differences with the standard datasets that are currently available in EcoInvent v3 have been found.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Environmental assessment tool to analyse the presence of critical and valuable raw materials

  • Gómez Bachiller, Patricia
  • Pina, Carmelo
  • Elduque, Daniel
  • Clavería, Isabel
  • Javierre, Carlos
  • Sarasa, Judith
The aim of this paper is show the software 'Sustainable Electronics' (SE), developed in the University of Zaragoza as an environmental impact assessment tool, specially developed to design components taking into account the presence of critical and valuable raw materials consumption; simulating environmental impact and measuring the overall raw material consumption, taking into account material composition of the electronic components. It considers raw material acquisition, manufacturing processes, transports and end of life. This software allows us to easily update and use the datasets provided by Life Cycle Inventory databases, such as, for example, EcoInvent, developed by the Swiss Centre for Life Cycle Inventories. The methodology has been tested through the software in an electronic board of a touch control used in an induction hob. As result, it has been obtained that there is a high consumption of materials such as copper, tin or aluminium.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Validation of the apple watch for heart rate variability measurements during relax and mental stress in healthy subjects

  • Hernando, D.
  • Roca, S.
  • Sancho, J.
  • Alesanco, Á.
  • Bailón, R.
Heart rate variability (HRV) analysis is a noninvasive tool widely used to assess autonomic nervous system state. The market for wearable devices that measure the heart rate has grown exponentially, as well as their potential use for healthcare and wellbeing applications. Still, there is a lack of validation of these devices. In particular, this work aims to validate the Apple Watch in terms of HRV derived from the RR interval series provided by the device, both in temporal (HRM (mean heart rate), SDNN, RMSSD and pNN50) and frequency (low and high frequency powers, LF and HF) domain. For this purpose, a database of 20 healthy volunteers subjected to relax and a mild cognitive stress was used. First, RR interval series provided by Apple Watch were validated using as reference the RR interval series provided by a Polar H7 using Bland-Altman plots and reliability and agreement coefficients. Then, HRV parameters derived from both RR interval series were compared and their ability to identify autonomic nervous system (ANS) response to mild cognitive stress was studied. Apple Watch measurements presented very good reliability and agreement (>0.9). RR interval series provided by Apple Watch contain gaps due to missing RR interval values (on average, 5 gaps per recording, lasting 6.5 s per gap). Temporal HRV indices were not significantly affected by the gaps. However, they produced a significant decrease in the LF and HF power. Despite these differences, HRV indices derived from the Apple Watch RR interval series were able to reflect changes induced by a mild mental stress, showing a significant decrease of HF power as well as RMSSD in stress with respect to relax, suggesting the potential use of HRV measurements derived from Apple Watch for stress monitoring.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A response surface optimization approach to adjust ionic current conductances of cardiac electrophysiological models. Application to the study of potassium level changes

  • Carro, J.
  • Pueyo, E.
  • Rodriguez Matas, J.F.
Cardiac electrophysiological computational models are often developed from previously published models. The new models may incorporate additional features to adapt the model to a different species or may upgrade a specific ionic formulation based on newly available experimental data. A relevant challenge in the development of a new model is the estimation of certain ionic current conductances that cannot be reliably identified from experiments. A common strategy to estimate those conductances is by means of constrained non-linear least-squares optimization. In this work, a novel methodology is proposed for estimation of ionic current conductances of cardiac electrophysiological models by using a response surface approximation-based constrained optimization with trust region management. Polynomial response surfaces of a number of electrophysiological markers were built using statistical sampling methods. These markers included action potential duration (APD), triangulation, diastolic and systolic intracellular calcium concentration, and time constants of APD rate adaptation. The proposed methodology was applied to update the Carro et al. human ventricular action potential model after incorporation of intracellular potassium ([K+]i) dynamics. While the Carro et al. model was well suited for investigation of arrhythmogenesis, it did not allow simulation of [K+]i changes. With the methodology proposed in this study, the updated Carro et al. human ventricular model could be used to simulate [K+]i changes in response to varying extracellular potassium ([K+]o) levels. Additionally, it rendered values of evaluated electrophysiological markers within physiologically plausible ranges. The optimal values of ionic current conductances in the updated model were found in a notably shorter time than with previously proposed methodologies. As a conclusion, the response surface optimization-based approach proposed in this study allows estimating ionic current conductances of cardiac electrophysiological computational models while guaranteeing replication of key electrophysiological features and with an important reduction in computational cost with respect to previously published approaches. The updated Carro et al. model developed in this study is thus suitable for the investigation of arrhythmic risk-related conditions, including those involving large changes in potassium concentration.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Otros (Other)

Editorial: Safety Pharmacology - Risk Assessment QT Interval Prolongation and Beyond

  • Grandi, E.
  • Morotti, S.
  • Pueyo, E.
  • Rodriguez, B.
The scope of safety pharmacology is to predict whether a drug is likely to cause potentially lethal adverse effects if administered to humans. While safety pharmacology has broadened its interests in recent years to the whole cardiovascular, respiratory, and central nervous systems (and is now extending to other body functions), a major focus since its inception has been assessing drug-induced prolongation in the QT interval—a surrogate biomarker for torsades de pointes (TdP) liability. Because the vast majority of drugs that can cause QT prolongation inhibit hERG channels, current regulatory guidelines concerning cardiac safety recommend that all compounds are evaluated in vitro for their hERG inhibitory potency (Redfern et al., 2003) and in vivo for their ability to cause QT/QTc interval prolongation (Food and Drug Administration, 2005) in an appropriate animal model and in humans. However, it has now become apparent that QT/QTc prolongation and hERG block are an insufficient proxy for TdP risk. While the current approach based on these markers has been successful in terms of preventing TdP risk, this regulatory paradigm might lead to withdrawal from the drug development pipeline and clinical use of potentially safe drugs. There is therefore a crucial need to develop a more accurate assessment of proarrhythmic potential of drugs...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

KCa3.1 Transgene Induction in Murine Intestinal Epithelium Causes Duodenal Chyme Accumulation and Impairs Duodenal Contractility.

  • Valero Gracia, Marta Sofía
  • Ramón Gimenez, Mariano
  • Lozano-Gerona, Javier
  • Delgado-Wicke, Pablo
  • Calmarza, Pilar
  • Olivan-Viguera, Aida
  • López, Víctor
  • García-Otín, Luís-Ángel
  • Valero, Salvador
  • Pueyo, Esther
  • Hamilton, Kir
  • Miura, Hioto
  • Köhler, Ralf
Abstract: The epithelial intermediate-conductance calcium/calmodulin-regulated KCa3.1 channel is considered to be a regulator of intestine function by controlling chloride secretion and water/salt balance. Yet, little is known about the functional importance of KCa3.1 in the intestinal epithelium in vivo. Our objective was to determine the impact of epithelial-specific inducible overexpression of a KCa3.1 transgene (KCa3.1+) and of inducible suppression (KCa3.1-) on intestinal homeostasis and function in mice. KCa3.1 overexpression in the duodenal epithelium of doxycycline (DOX)-treated KCa3.1+ mice was 40-fold above the control levels. Overexpression caused an inflated duodenum and doubling of the chyme content. Histology showed conserved architecture of crypts, villi, and smooth muscle. Unaltered proliferating cell nuclear antigen (PCNA) immune reactivity and reduced amounts of terminal deoxynucleotide transferase mediated X-dUTP nick end labeling (TUNEL)-positive apoptotic cells in villi indicated lower epithelial turnover. Myography showed a reduction in the frequency of spontaneous propulsive muscle contractions with no change in amplitude. The amount of stool in the colon was increased and the frequency of colonic contractions was reduced in KCa3.1+ animals. Senicapoc treatment prevented the phenotype. Suppression of KCa3.1 in DOX-treated KCa3.1- mice caused no overt intestinal phenotype. In conclusion, inducible KCa3.1 overexpression alters intestinal functions by increasing the chyme content and reducing spontaneous contractions and epithelial apoptosis. Induction of epithelial KCa3.1 can play a mechanistic role in the process of adaptation of the intestine.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Automatic diagnosis of strict left bundle branch block using a wavelet-based approach

  • Martín-Yebra, A.
  • Martínez, J.P.
Patients with left bundle branch block (LBBB) are known to have a good clinical response to cardiac resynchronization therapy. However, the high number of false positive diagnosis obtained with the conventional LBBB criteria limits the effectiveness of this therapy, which has yielded to the definition of new stricter criteria. They require prolonged QRS duration, a QS or rS pattern in the QRS complexes at leads V1 and V2 and the presence of mid-QRS notch/slurs in 2 leads within V1, V2, V5, V6, I and aVL. The aim of this work was to develop and assess a fully-automatic algorithm for strict LBBB diagnosis based on the wavelet transform. Twelve-lead, high-resolution, 10-second ECGs from 602 patients enrolled in the MADIT-CRT trial were available. Data were labelled for strict LBBB by 2 independent experts and divided into training (n = 300) and validation sets (n = 302) for assessing algorithm performance. After QRS detection, a wavelet-based delineator was used to detect individual QRS waves (Q, R, S), QRS onsets and ends, and to identify the morphological QRS pattern on each standard lead. Then, multilead QRS boundaries were defined in order to compute the global QRS duration. Finally, an automatic algorithm for notch/slur detection within the QRS complex was applied based on the same wavelet approach used for delineation. In the validation set, LBBB was diagnosed with a sensitivity and specificity of Se = 92.9% and Sp = 65.1% (Acc = 79.5%, PPV = 74% and NPV = 89.6%). The results confirmed that diagnosis of strict LBBB can be done based on a fully automatic extraction of temporal and morphological QRS features. However, it became evident that consensus in the definition of QRS duration as well as notch and slurs definitions is necessary in order to guarantee accurate and repeatable diagnosis of complete LBBB.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Baroreflex sensitivity measured by pulse photoplethysmography

  • Lázaro, Jesús
  • Gil, Eduardo
  • Orini, Michele
  • Laguna, Pablo
  • Bailón, Raquel
Novel methods for assessing baroreflex sensitivity (BRS) using only pulse photoplethysmography (PPG) signals are presented. Proposed methods were evaluated with a data set containing electrocardiogram (ECG), blood pressure (BP), and PPG signals from 17 healthy subjects during a tilt table test. The methods are based on a surrogate of a index, which is defined as the power ratio of RR interval variability (RRV) and that of systolic arterial pressure series variability (SAPV). The proposed a index surrogates use pulse-to-pulse interval series variability (PPV) as a surrogate of RRV, and different morphological features of the PPG pulse which have been hypothesized to be related to BP, as series surrogates of SAPV. A time-frequency technique was used to assess BRS, taking into account the non-stationarity of the protocol. This technique identifies two time-varying frequency bands where RRV and SAPV (or their surrogates) are expected to be coupled: the low frequency (LF, inside 0.04–0.15 Hz range), and the high frequency (HF, inside 0.15–0.4 Hz range) bands. Furthermore, time-frequency coherence is used to identify the time intervals when the RRV and SAPV (or their surrogates) are coupled. Conventional a index based on RRV and SAPV was used as Gold Standard. Spearman correlation coefficients between conventional a index and its PPG-based surrogates were computed and the paired Wilcoxon statistical test was applied in order to assess whether the indices can find significant differences (p < 0.05) between different stages of the protocol. The highest correlations with the conventional a index were obtained by the a-index-surrogate based on PPV and pulse up-slope (PUS), with 0.74 for LF band, and 0.81 for HF band. Furthermore, this index found significant differences between rest stages and tilt stage in both LF and HF bands according to the paired Wilcoxon test, as the conventional a index also did. These results suggest that BRS changes induced by the tilt test can be assessed with high correlation by only a PPG signal using PPV as RRV surrogate, and PPG morphological features as SAPV surrogates, being PUS the most convenient SAPV surrogate among the studied ones.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Quantification of Ventricular Repolarization Variation for Sudden Cardiac Death Risk Stratification in Atrial Fibrillation

  • Martín Yebra, Alba
  • Laguna, Pablo
  • Cygankiewicz, Iwona
  • Bayés-de-Luna, Antoni
  • Caiani, Enrico G.
  • Martínez, Juan Pablo
Objective: Atrial fibrillation (AF) rhythm gives rise to an irregular response in ventricular activity, preventing the use of standard ECG-derived risk markers based on ventricular repolarization heterogeneity under this particular condition. In this study we proposed new indices to quantify repolarization variations in AF patients, assessing their stratification performance in a chronic heart failure (CHF) population with AF. Methods: We developed a method based on a selective bin averaging technique. Consecutive beats preceded by a similar RR interval were selected, from which the average variation within the ST-T complex for each RR range was computed.We proposed two sets of indices: (i) the 2-beat index of ventricular repolarization variation, (I_V2), computed from pairs of stable consecutive beats; and (ii) the 3-beat indices of ventricular repolarization variation, computed in triplets of stable consecutive beats (I_V3). Results: These indices showed a significant association with sudden cardiac death (SCD) outcome in the study population. In addition, risk assessment based on the combination of the proposed indices improved stratification performance compared to their individual potential. Conclusion: Patients with enhanced ventricular repolarization variation computed in terms of the proposed indices were successfully associated to a higher SCD incidence in our study population, evidencing their prognostic value. Significance: using a simple ambulatory ECG recording, it is possible to stratify AF patients at risk of SCD, which may help cardiologists in adopting most effective therapeutic strategies, with a positive impact in both the patient and healthcare systems.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic dysfunction increases cardiovascular risk in the presence of sleep apnea

  • Milagro, Javier
  • Deviaene, Margot
  • Gil, Eduardo
  • Lazaro, Jesús
  • Buyse, Bertien
  • Testelmans, Dries
  • Borzée, Pascal
  • Willems, Rik
  • Van Huffel, Sabine
  • Bailón, Raquel
  • Varon, Carolina
The high prevalence of sleep apnea syndrome (SAS) and its direct relationship with an augmented risk of cardiovascular disease (CVD) have raised SAS as a primary public health problem. For this reason, extensive research aiming to understand the interaction between both conditions has been conducted. The advances in non-invasive autonomic nervous system (ANS) monitoring through heart rate variability (HRV) analysis have revealed an increased sympathetic dominance in subjects suffering from SAS when compared with controls. Similarly, HRV analysis of subjects with CVD suggests altered autonomic activity. In this work, we investigated the altered autonomic control in subjects suffering from SAS and CVD simultaneously when compared with SAS patients, as well as the possibility that ANS assessment may be useful for the early stage identification of cardiovascular risk in subjects with SAS. The analysis was performed over 199 subjects from two independent datasets during night-time, and the effects of the physiological response following an apneic episode, sleep stages, and respiration on HRV were taken into account. Results, as measured by HRV, suggest a decreased sympathetic dominance in those subjects suffering from both conditions, as well as in subjects with SAS that will develop CVDs, which was reflected in a significantly reduced sympathovagal balance (p < 0.05). In this way, ANS monitoring could contribute to improve screening and diagnosis, and eventually aid in the phenotyping of patients, as an altered response might have direct implications on cardiovascular health.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Electrocardiogram-derived tidal volume during treadmill stress test

  • Milagro, Javier
  • Hernando, David
  • Lázaro, Jesús
  • Casajús, Jose Antonio
  • Garatachea, Nuria
  • Gil, Eduardo
  • Bailón, Raquel
Objective: Electrocardiogram (ECG) has been regarded as a source of respiratory information with the main focus in the estimation of the respiratory rate. Although little research concerning the estimation of tidal volume (TV) has been conducted, there are several ECG-derived features that have been related with TV in the literature, such as ECG-derived respiration, heart rate variability or respiratory rate. In this work, we exploited these features for estimating TV using a linear model. Methods: 25 young (33.4 ± 5.2 years) healthy male volunteers were recruited for performing a maximal (MaxT) and a submaximal (SubT) treadmill stress test, which were conducted in different days. Both tests were automatically segmented in stages attending to the heart rate. Afterwards, a subject-specific TV model was calibrated for each stage, employing features from MaxT, and the model was later used for estimating the TV in SubT. Results: During exercise, the different proposed approaches led to relative fitting errors lower than 14% in most of the cases and than 6% in some of them. Conclusion: Low achieved fitting errors suggest that TV can be estimated from ECG during a treadmill stress test. Significance: The results suggest that it is possible to estimate TV during exercise using only ECG-derived features.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmographic Waveform Versus Heart Rate Variability to Identify Low Stress States. Attention Test

  • Peláez Coca, María Dolores
  • Lozano Albalate, María Teresa
  • Hernando Sanz, Alberto
  • Aiger Vallés, Montserrat
  • Gil, Eduardo
Our long-term goal is the development of an automatic identifier of attentional states. In order to accomplish it, we should firstly be able to identify different states based on physiological signals. So, the first aim of this work is to identify the most appropriate features, to detect a subject high performance state. For that, a database of electrocardiographic (ECG) and photopletysmographic (PPG) signals is recorded in two unequivocally defined states (rest and attention task) from up to 50 subjects as a sample of the population. Time and frequency parameters of heart/pulse rate variability have been computed from the ECG/PPG signals respectively. Additionally, the respiratory rate has been estimated from both signals and also six morphological parameters from PPG. In total, twenty six features are obtained for each subject. They provide information about the autonomic nervous system and the physiological response of the subject to an attention demand task. Results show an increase of sympathetic activation when the subjects perform the attention test. The amplitude and width of the PPG pulse were more sensitive that the classical sympathetic markers (normalised power in LF and LF/HF ratio) for identifying this attentional state. State classification accuracy reaches a mean of 89 $\pm$ 2%, a maximum of 93% and a minimum of 85%, in the hundred classifications made by only selecting four parameters extracted from the PPG signal (pulse amplitude, pulse width, pulse downward slope and mean pulse rate). These results suggest that attentional states could be identified by PPG.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG-derived respiratory rate in atrial fibrillation

  • Kontaxis, Spyridon
  • Lázaro Plaza, Jesús
  • Corino, Valentina
  • Sandberg, Frida
  • Bailón Luesma, Raquel
  • Laguna Lasaosa, Pablo
  • Sörnmo, Leif
Objective: The present study addresses the problem of estimating the respiratory rate from the morphological ECG variations in the presence of atrial fibrillatory waves (f-waves). The significance of performing f-wave suppression before respiratory rate estimation is investigated. Methods: The performance of a novel approach to ECG-derived respiration, named “slope range” (SR) and designed particularly for operation in atrial fibrillation (AF), is compared to that of two well-known methods based on either R-wave angle (RA) or QRS loop rotation angle (LA). A novel rule is proposed for spectral peak selection in respiratory rate estimation. The suppression of f-waves is accomplished using signal- and noise-dependent QRS weighted averaging. The performance evaluation embraces real as well as simulated ECG signals acquired from patients with persistent AF; the estimation error of the respiratory rate is determined for both types of signals. Results: Using real ECG signals and reference respiratory signals, rate estimation without f-wave suppression resulted in a median error of 0.015±0.021 Hz and 0.019±0.025 Hz for SR and RA, respectively, whereas LA with f-wave suppression resulted in 0.034±0.039 Hz. Using simulated signals, the results also demonstrate that f-wave suppression is superfluous for SR and RA, whereas it is essential for LA. Conclusion: The results show that SR offers the best performance as well as computational simplicity since f-wave suppression is not needed. Significance: The respiratory rate can be robustly estimated from the ECG in the presence of AF.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Finger and forehead PPG signal comparison for respiratory rate estimation

  • Hernando, Alberto
  • Peláez-Coca, María Dolores
  • Lozano, María Teresa
  • Lázaro, Jesús
  • Gil, Eduardo
Objective: an evaluation of the location of the photoplethysmogram (PPG) sensor for respiratory rate estimation is performed. Approach: finger-PPG, forehead-PPG, and respiratory signal were simultaneously recorded from 35 subjects while breathing spontaneously, and during controlled respiration experiments at a constant rate from 0.1 Hz to 0.6 Hz, in 0.1 Hz steps. Four PPG derived respiratory (PDR) signals were extracted from each one of the recorded PPG signals: pulse rate variability (PRV), pulse width variability (PWV), pulse amplitude variability (PAV) and the respiratory- induced intensity variability (RIIV). Respiratory rate was estimated from each one of the 4 PDR signals for both PPG sensor locations. In addition, different combinations of PDR signals, power distribution of the respiratory frequency range and differences of the morphological parameters extracted from both PPG signals have been analysed. Main results: results show a better performance in terms of successful estimation and relative error when: i) PPG signal is recorded in the finger; ii) the respiratory rate is less than 0.4 Hz; iii) RIIV signal is not considered. Furthermore, lower spectral power around the respiratory rate in the PDR signals recorded from the forehead was observed. Significance: these results suggest that respiratory rate estimation is better at lower rates (0.4 Hz and below) and that finger is better than forehead to estimate respiratory rate.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Optimal fiducial points for pulse rate variability analysis from forehead and finger PPG signals

  • Peralta Calvo, Elena
  • Lázaro Plaza, Jesús
  • Bailón Luesma, Raquel
  • Marozas, Vaidotas
  • Gil Herrando, Eduardo
Objective: The aim of this work is to evaluate and compare five fiducialpoints for the temporal location of each pulse wave from forehead and fingerphotoplethysmographic pulse waves signals (PPG) to perform pulse rate variability(PRV) analysis as a surrogate of heart rate variability (HRV) analysis. Approach: Forehead and finger PPG signals were recorded during tilt-table testsimultaneously to the ECG. Artifacts were detected and removed and, five fiducialpoints were computed: apex, middle-amplitude and foot points of the PPG signal,apex point of the first derivative signal and, the intersection point of the tangent tothe PPG waveform at the apex of the derivative PPG signal and the tangent to thefoot of the PPG pulse defined as intersecting tangents method. Pulse period (PP)time intervals series were obtained from both PPG signals and compared to the RRintervals obtained from the ECG. Heart and pulse rate variability signals (HRV andPRV) were estimated and, classical time and frequency domain indices were computed. Main Results: The middle-amplitude point of the PPG signal (nM), the apexpoint of the first derivative (n*A), and the tangents intersection point (nT) are themost suitable fiducial points for PRV analysis, which result in the lowest relativeerrors estimated between PRV and HRV indices, higher correlation coefficients and reliability indexes. Statistically significant differences according to the Wilcoxon testbetween PRV and HRV signals were found for the apex and foot fiducial points ofthe PPG, as well as the lowest agreement between RR and PP series according toBland-Altman analysis. Hence, they have been considered less accurate for variabilityanalysis. In addition, the relative errors are significantly lower fornMandn*Afeaturesby using Friedman statistics with Bonferroni multiple-comparison test and, we proposenMas the most accurate fiducial point. Based on our results, forehead PPG seems toprovide more reliable information for a PRV assessment than finger PPG. Significance: The accuracy of the pulse wave detections depends on the morphologyof the PPG. There is therefore a need to widely define the most accurate fiducial pointto perform a PRV analysis under non-stationary conditions based on different PPGsensor locations and signal acquisition techniques.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The Effect of Emotional Valence on Ventricular Repolarization Dynamics Is Mediated by Heart Rate Variability: A Study of QT Variability and Music-Induced Emotions

  • Orini, Michele
  • Al-Amodi, Faez
  • Koelsch, Stefan
  • Bailón, Raquel
Background: Emotions can affect cardiac activity, but their impact on ventricular repolarization variability, an important parameter providing information about cardiac risk and autonomic nervous system activity, is unknown. The beat-to-beat variability of the QT interval (QTV) from the body surface ECG is a non-invasive marker of repolarization variability, which can be decomposed into QTV related to RR variability (QTVrRRV) and QTV unrelated to RRV (QTVuRRV), with the latter thought to be a marker of intrinsic repolarization variability. Aim: To determine the effect of emotional valence (pleasant and unpleasant) on repolarization variability in healthy volunteers by means of QTV analysis. Methods: 75 individuals (24.5 ± 3.2 years, 36 females) without a history of cardiovascular disease listened to music-excerpts that were either felt as pleasant (n = 6) or unpleasant (n = 6). Excerpts lasted about 90 s and were presented in a random order along with silent intervals (n = 6). QTV and RRV were derived from the ECG and the time-frequency spectrum of RRV, QTV, QTVuRRV and QTVrRRV as well as time-frequency coherence between QTV and RRV were estimated. Analysis was performed in low-frequency (LF), high frequency (HF) and total spectral bands. Results: The heart rate-corrected QTV showed a small but significant increase from silence (median 347/interquartile range 31 ms) to listening to music felt as unpleasant (351/30 ms) and pleasant (355/32 ms). The dynamic response of QTV to emotional valence showed a transient phase lasting about 20 s after the onset of each musical excerpt. QTV and RRV were highly correlated in both HF and LF (mean coherence ranging 0.76–0.85). QTV and QTVrRRV decreased during listening to music felt as pleasant and unpleasant with respect to silence and further decreased during listening to music felt as pleasant. QTVuRRV was small and not affected by emotional valence. Conclusion: Emotional valence, as evoked by music, has a small but significant effect on QTV and QTVrRRV, but not on QTVuRRV. This suggests that the interaction between emotional valence and ventricular repolarization variability is mediated by cycle length dynamics and not due to intrinsic repolarization variability.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Long-term microgravity exposure increases ECG repolarization instability manifested by low-frequency oscillations of T-Wave vector

  • Palacios, Saúl
  • Caiani, Enrico G.
  • Landreani, Federica
  • Martínez, Juan Pablo
  • Pueyo, Esther
Ventricular arrhythmias and sudden cardiac death during long-term space missions are a major concern for space agencies. Long-duration spaceflight and its ground-based analog head-down bed rest (HDBR) have been reported to markedly alter autonomic and cardiac functioning, particularly affecting ventricular repolarization of the electrocardiogram (ECG). In this study, novel methods are developed, departing from previously published methodologies, to quantify the index of Periodic Repolarization Dynamics (PRD), an arrhythmic risk marker that characterizes sympathetically-mediated low-frequency oscillations in the T-wave vector. PRD is evaluated in ECGs from 42 volunteers at rest and during an orthostatic tilt table test recorded before and after 60-day –6° HDBR. Our results indicate that tilt test, on top of enhancing sympathetic regulation of heart rate, notably increases PRD, both before and after HDBR, thus supporting previous evidence on PRD being an indicator of sympathetic modulation of ventricular repolarization. Importantly, long-term microgravity exposure is shown to lead to significant increases in PRD, both when evaluated at rest and, even more notably, in response to tilt test. The extent of microgravity-induced changes in PRD has been associated with arrhythmic risk in prior studies. An exercise-based, but not a nutrition-based, countermeasure is able to partially reverse microgravity-induced effects on PRD. In conclusion, long-term exposure to microgravity conditions leads to elevated low-frequency oscillations of ventricular repolarization, which are potentiated following sympathetic stimulation and are related to increased risk for repolarization instabilities and arrhythmias. Tested countermeasures are only partially effective in counteracting microgravity effects.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Reperfusion Arrhythmias Increase after Superior Cervical Ganglionectomy Due to Conduction Disorders and Changes in Repolarization

  • Prado, Natalia J.
  • Muñoz, Estela M.
  • Farias Altamirano, Luz E.
  • Aguiar, Francisco
  • Ponce Zumino, Amira Z.
  • Sánchez, Francisco J.
  • Miatello, Roberto M.
  • Pueyo, Esther
  • Diez, Emiliano Raúl
Pharmacological concentrations of melatonin reduce reperfusion arrhythmias, but less is known about the antiarrhythmic protection of the physiological circadian rhythm of melatonin. Bilateral surgical removal of the superior cervical ganglia irreversibly suppresses melatonin rhythmicity. This study aimed to analyze the cardiac electrophysiological effects of the loss of melatonin circadian oscillation and the role played by myocardial melatonin membrane receptors, SERCA2A, TNFa, nitrotyrosine, TGFß, KATP channels, and connexin 43. Three weeks after bilateral removal of the superior cervical ganglia or sham surgery, the hearts were isolated and submitted to ten minutes of regional ischemia followed by ten minutes of reperfusion. Arrhythmias, mainly ventricular tachycardia, increased during reperfusion in the ganglionectomy group. These hearts also suffered an epicardial electrical activation delay that increased during ischemia, action potential alternants, triggered activity, and dispersion of action potential duration. Hearts from ganglionectomized rats showed a reduction of the cardioprotective MT2 receptors, the MT1 receptors, and SERCA2A. Markers of nitroxidative stress (nitrotyrosine), inflammation (TNFa), and fibrosis (TGFß and vimentin) did not change between groups. Connexin 43 lateralization and the pore-forming subunit (Kir6.1) of KATP channels increased in the experimental group. We conclude that the loss of the circadian rhythm of melatonin predisposes the heart to suffer cardiac arrhythmias, mainly ventricular tachycardia, due to conduction disorders and changes in repolarization.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Conditional KCa3.1-transgene induction in murine skin produces pruritic eczematous dermatitis with severe epidermal hyperplasia and hyperkeratosis

  • Lozano-Gerona, J.
  • Oliván-Viguera, A.
  • Delgado-Wicke, P.
  • Singh, V.
  • Brown, B.M.
  • Tapia-Casellas, E.
  • Pueyo, E.
  • Valero, M.S.
  • Garcia-Otín, Á.L.
  • Giraldo, P.
  • Abarca-Lachen, E.
  • Surra, J.C.
  • Osada, J.
  • Hamilton, K.L.
  • Raychaudhuri, S.P.
  • Marigil, M.
  • Juarranz, Á.
  • Wulff, H.
  • Miura, H.
  • Gilaberte, Y.
  • Köhler, R.
Ion channels have recently attracted attention as potential mediators of skin disease. Here, we explored the consequences of genetically encoded induction of the cell volume-regulating Ca2+-activated KCa3.1 channel (Kcnn4) for murine epidermal homeostasis. Doxycycline-treated mice harboring the KCa3.1+-transgene under the control of the reverse tetracycline-sensitive transactivator (rtTA) showed 800-fold channel overexpression above basal levels in the skin and solid KCa3.1-currents in keratinocytes. This overexpression resulted in epidermal spongiosis, progressive epidermal hyperplasia and hyperkeratosis, itch and ulcers. The condition was accompanied by production of the pro-proliferative and pro-inflammatory cytokines, IL-ß1 (60-fold), IL-6 (33-fold), and TNFa (26-fold) in the skin. Treatment of mice with the KCa3.1-selective blocker, Senicapoc, significantly suppressed spongiosis and hyperplasia, as well as induction of IL-ß1 (-88%) and IL-6 (-90%). In conclusion, KCa3.1-induction in the epidermis caused expression of pro-proliferative cytokines leading to spongiosis, hyperplasia and hyperkeratosis. This skin condition resembles pathological features of eczematous dermatitis and identifies KCa3.1 as a regulator of epidermal homeostasis and spongiosis, and as a potential therapeutic target.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Data-Driven Identification of Stochastic Model Parameters and State Variables: Application to the Study of Cardiac Beat-to-Beat Variability

  • Sampedro-Puente, David Adolfo
  • Fernández-Bes, Jesús
  • Virág, László
  • Varró, András
  • Pueyo, Esther
Enhanced spatiotemporal ventricular repolarization variability has been associated with ventricular arrhythmias and sudden cardiac death, but the involved mechanisms remain elusive. In this paper, a methodology for estimation of parameters and state variables of stochastic human ventricular cell models from input voltage data is proposed for investigation of repolarization variability. Methods: The proposed methodology formulates state-space representations based on developed stochastic cell models and uses the unscented Kalman filter to perform joint parameter and state estimation. Evaluation over synthetic and experimental data is presented. Results: Results on synthetically generated data show the ability of the methodology to: first, filter out measurement noise from action potential (AP) traces; second, identify model parameters and state variables from each of those individual AP traces, thus allowing robust characterization of cell-to-cell variability; and, third, replicate statistical population''s distributions of input AP-based markers, including dynamic markers quantifying beat-to-beat variability. Application onto experimental data demonstrates the ability of the methodology to match input AP traces while concomitantly inferring the characteristics of underlying stochastic cell models. Conclusion: A novel methodology is presented for estimation of parameters and hidden variables of stochastic cardiac computational models, with the advantage of providing a one-to-one match between each individual AP trace and a corresponding set of model characteristics. Significance: The proposed methodology can greatly help in the characterization of temporal (beat-to-beat) and spatial (cell-to-cell) variability in human ventricular repolarization and in ascertaining the corresponding underlying mechanisms, particularly in scenarios with limited available experimental data.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Bifurcations and Slow-Fast Analysis in a Cardiac Cell Model for Investigation of Early Afterdepolarizations

  • Barrio, R.
  • Martinez, M.A.
  • Perez, L.
  • Pueyo, E.
In this study, we teased out the dynamical mechanisms underlying the generation of arrhythmogenic early afterdepolarizations (EADs) in a three-variable model of a mammalian ventricular cell. Based on recently published studies, we consider a 1-fast, 2-slow variable decomposition of the system describing the cellular action potential. We use sweeping techniques, such as the spike-counting method, and bifurcation and continuation methods to identify parametric regions with EADs. We show the existence of isolas of periodic orbits organizing the different EAD patterns and we provide a preliminary classification of our fast-slow decomposition according to the involved dynamical phenomena. This investigation represents a basis for further studies into the organization of EAD patterns in the parameter space and the involved bifurcations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Automatic detection of slow conducting channels during substrate ablation of scar-related ventricular arrhythmias

  • Alcaine, Alejandro
  • Jáuregui, Beatriz
  • Soto-Iglesias, David
  • Acosta, Juan
  • Penela, Diego
  • Fernández-Armenta, Juan
  • Linhart, Markus
  • Andreu, David
  • Mont, Lluis
  • Laguna, Pablo
  • Cámara, Óscar
  • Martínez, Juan Pablo
  • Berruezo, Antonio
Background. Voltage mapping allows identifying the arrhythmogenic substrate during scar-related ventricular arrhythmia (VA) ablation procedures. Slow conducting channels (SCCs), defined by the presence of electrogram (EGM) signals with delayed components (EGM-DC), are responsible for sustaining VAs and constitute potential ablation targets. However, voltage mapping, as it is currently performed, is time-consuming, requiring a manual analysis of all EGMs to detect SCCs, and its accuracy is limited by electric far-field. We sought to evaluate an algorithm that automatically identifies EGM-DC, classifies mapping points, and creates new voltage maps, named "Slow Conducting Channel Maps" (SCC-Maps). Methods. Retrospective analysis of electroanatomic maps (EAM) from 20 patients (10 ischemic, 10 with arrhythmogenic right ventricular dysplasia/cardiomyopathy) was performed. EAM voltage maps were acquired during sinus rhythm and used for ablation. Preprocedural contrast-enhanced cardiac magnetic resonance (Ce-CMR) imaging was available for the ischemic population. Three mapping modalities were analysed: (i) EAM voltage maps using standard (EAM standard) or manual (EAM screening) thresholds for defining core and border zones; (ii) SCC-Maps derived from the use of the novel SCC-Mapping algorithm that automatically identify EGM-DCs measuring the voltage of the local component; and (iii) Ce-CMR maps (when available). The ability of each mapping modality in identifying SCCs and their agreement was evaluated. Results. SCC-Maps and EAM screening identified a greater number of SCC entrances than EAM standard (3.45 ± 1.61 and 2.95 ± 2.31, resp., vs. 1.05 ± 1.10; p<0.01). SCC-Maps and EAM screening highly correlate with Ce-CMR maps in the ischemic population when compared to EAM standard (Lin''s correlation = 0.628 and 0.679, resp., vs. 0.212, p<0.01). Conclusion. The SCC-Mapping algorithm allows an operator-independent analysis of EGM signals showing better identification of the arrhythmogenic substrate characteristics when compared to standard voltage EAM.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Otros (Other)

Editorial: Perspectives of Antiarrhythmic Drug Therapy: Disappointing Past, Current Efforts, and Faint Hopes

  • Nánási, P.P.
  • Pueyo, E.
  • Virág, L.
Present issue is devoted to those areas of cardiac electrophysiology, pathophysiology, and pharmacology which are critically important to improve the efficacy of antiarrhythmic treatment. Cardiac arrhythmia is a leading cause of morbidity and mortality, and the history of anti-arrhythmic drug therapies has been dismal...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmographic waveform analysis for autonomic reactivity assessment in depression

  • Kontaxis, Spyridon
  • Gil, Eduardo
  • Marozas, Vaidotas
  • Lázaro, Jesús
  • García, Esther
  • Posadas-de Miguel, Mar
  • Siddi, Sara
  • Bernal, María Luisa
  • Aguiló, Jordi
  • Haro, Josep María
  • de la Cámara, Concepción
  • Laguna, Pablo
  • Bailón, Raquel
Objective: In the present study, a photoplethysmographic (PPG) waveform analysis for assessing differences in autonomic reactivity to mental stress between patients with Major Depressive Disorder (MDD) and healthy control (HC) subjects is presented. Methods: PPG recordings of 40 MDD and 40 HC subjects were acquired at basal conditions, during the execution of cognitive tasks, and at the post-task relaxation period. PPG pulses are decomposed into three waves (a main wave and two reflected waves) using a pulse decomposition analysis. Pulse waveform characteristics such as the time delay between the position of the main wave and reflected waves, the percentage of amplitude loss in the reflected waves, and the heart rate (HR) are calculated among others. The intra-subject difference of a feature value between two conditions is used as an index of autonomic reactivity. Results: Statistically significant individual differences from stress to recovery were found for HR and the percentage of amplitude loss in the second reflected wave ( A13 ) in both HC and MDD group. However, autonomic reactivity indices related to A13 reached higher values in HC than in MDD subjects (Cohen's d =0.81, AUC = 0.74), implying that the stress response in depressed patients is reduced. A statistically significant (p < 0.001) negative correlation (r = 0.5) between depression severity scores and A13 was found. Conclusion: A decreased autonomic reactivity is associated with higher degree of depression. Significance: Stress response quantification by dynamic changes in PPG waveform morphology can be an aid for the diagnosis and monitoring of depression.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Automatic quantification of cardiomyocyte dimensions and connexin 43 lateralization in fluorescence images

  • Oliver-Gelabert, A.
  • García-Mendívil, L.
  • Vallejo-Gil, J.M.
  • Fresneda-Roldán, P.C.
  • Andelová, K.
  • Fañanás-Mastral, J.
  • Vázquez-Sancho, M.
  • Matamala-Adell, M.
  • Sorribas-Berjón, F.
  • Ballester-Cuenca, C.
  • Tribulova, N.
  • Ordovás, L.
  • Diez, E.R.
  • Pueyo, E.
Cardiomyocytes’ geometry and connexin 43 (CX43) amount and distribution are structural features that play a pivotal role in electrical conduction. Their quantitative assessment is of high interest in the study of arrhythmias, but it is usually hampered by the lack of automatic tools. In this work, we propose a software algorithm (Myocyte Automatic Retrieval and Tissue Analyzer, MARTA) to automatically detect myocytes from fluorescent microscopy images of cardiac tissue, measure their morphological features and evaluate the expression of CX43 and its degree of lateralization. The proposed software is based on the generation of cell masks, contouring of individual cells, enclosing of cells in minimum area rectangles and splitting of these rectangles into end-to-end and middle compartments to estimate CX43 lateral-to-total ratio. Application to human ventricular tissue images shows that mean differences between automatic and manual methods in terms of cardiomyocyte length and width are below 4 µm. The percentage of lateral CX43 also agrees between automatic and manual evaluation, with the interquartile range approximately covering from 3% to 30% in both cases. MARTA is not limited by fiber orientation and has an optimized speed by using contour filtering, which makes it run hundreds of times faster than a trained expert. Developed for CX43 studies in the left ventricle, MARTA is a flexible tool applicable to morphometric and lateralization studies of other markers in any heart chamber or even skeletal muscle. This open-access software is available online.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Time Course of Low-Frequency Oscillatory Behavior in Human Ventricular Repolarization Following Enhanced Sympathetic Activity and Relation to Arrhythmogenesis

  • Sampedro-Puente, David Adolfo
  • Fernandez-Bes, Jesús
  • Szentandrassy, Norbert
  • Nanasi, Péter
  • Taggart, Peter
  • Pueyo, Esther
Background and Objectives: Recent studies in humans and dogs have shown that ventricular repolarization exhibits a low-frequency (LF) oscillatory pattern following enhanced sympathetic activity, which has been related to arrhythmic risk. The appearance of LF oscillations in ventricular repolarization is, however, not immediate, but it may take up to some minutes. This study seeks to characterize the time course of the action potential (AP) duration (APD) oscillatory behavior in response to sympathetic provocations, unveil its underlying mechanisms and establish a potential link to arrhythmogenesis under disease conditions. Materials and Methods: A representative set of human ventricular computational models coupling cellular electrophysiology, calcium dynamics, β-adrenergic signaling, and mechanics was built. Sympathetic provocation was modeled via phasic changes in β-adrenergic stimulation (β-AS) and mechanical stretch at Mayer wave frequencies within the 0.03–0.15 Hz band. Results: Our results show that there are large inter-individual differences in the time lapse for the development of LF oscillations in APD following sympathetic provocation, with some cells requiring just a few seconds and other cells needing more than 3 min. Whereas, the oscillatory response to phasic mechanical stretch is almost immediate, the response to β-AS is much more prolonged, in line with experimentally reported evidences, thus being this component the one driving the slow development of APD oscillations following enhanced sympathetic activity. If β-adrenoceptors are priorly stimulated, the time for APD oscillations to become apparent is remarkably reduced, with the oscillation time lapse being an exponential function of the pre-stimulation level. The major mechanism underlying the delay in APD oscillations appearance is related to the slow IKs phosphorylation kinetics, with its relevance being modulated by the IKs conductance of each individual cell. Cells presenting short oscillation time lapses are commonly associated with large APD oscillation magnitudes, which facilitate the occurrence of pro-arrhythmic events under disease conditions involving calcium overload and reduced repolarization reserve. Conclusions: The time course of LF oscillatory behavior of APD in response to increased sympathetic activity presents high inter-individual variability, which is associated with different expression and PKA phosphorylation kinetics of the IKs current. Short time lapses in the development of APD oscillations are associated with large oscillatory magnitudes and pro-arrhythmic risk under disease conditions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mechanisms Underlying Interactions Between Low-Frequency Oscillations and Beat-to-Beat Variability of Celullar Ventricular Repolarization in Response to Sympathetic Stimulation: Implications for Arrhythmogenesis

  • Sampedro-Puente, David Adolfo
  • Fernandez-Bes, Jesús
  • Porter, Bradley
  • Duijvenboden, Stef an van
  • Taggart, Peter
  • Pueyo, Esther
Background and Objectives: Enhanced beat-to-beat variability of ventricular repolarization (BVR) has been linked to arrhythmias and sudden cardiac death. Recent experimental studies on human left ventricular epicardial electrograms have shown that BVR closely interacts with low-frequency (LF) oscillations of activation recovery interval during sympathetic provocation. In this work human ventricular computational cell models are developed to reproduce the experimentally observed interactions between BVR and its LF oscillations, to assess underlying mechanisms and to establish a relationship with arrhythmic risk. Materials and Methods: A set of human ventricular action potential (AP) models covering a range of experimental electrophysiological characteristics was constructed. These models incorporated stochasticity in major ionic currents as well as descriptions of ß-adrenergic stimulation and mechanical effects to investigate the AP response to enhanced sympathetic activity. Statistical methods based on Automatic Relevance Determination and Canonical Correlation Analysis were developed to unravel individual and common factors contributing to BVR and LF patterning of APD in response to sympathetic provocation. Results: Simulated results reproduced experimental evidences on the interactions between BVR and LF oscillations of AP duration (APD), with replication of the high inter-individual variability observed in both phenomena. ICaL, IKr and IK1 currents were identified as common ionic modulators of the inter-individual differences in BVR and LF oscillatory behavior and were shown to be crucial in determining susceptibility to arrhythmogenic events. Conclusions: The calibrated family of human ventricular cell models proposed in this study allows reproducing experimentally reported interactions between BVR and LF oscillations of APD. Ionic factors involving ICaL, IKr and IK1 currents are found to underlie correlated increments in both phenomena in response to sympathetic provocation. A link to arrhythmogenesis is established for concomitantly elevated levels of BVR and its LF oscillations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Heart Rate Variability and Exceptional Longevity

  • Hernández-Vicente, A.
  • Hernando, D.
  • Santos-Lozano, A.
  • Rodríguez-Romo, G.
  • Vicente-Rodríguez, G.
  • Pueyo, E.
  • Bailón, R.
  • Garatachea, N.
Centenarians are the paradigm of human extreme longevity and healthy aging, because they have postponed, if not avoided, mayor age-related diseases. The purpose of this study was to investigate potential differences in resting heart rate variability (HRV) between young adults, octogenarians, and centenarians and assess whether HRV variables are predictors of all-cause mortality in centenarians. To this end, three groups of participants: young adults (N = 20; 20.6 ± 2.3 years), octogenarians (N = 18; 84.1 ± 2.6 years), and centenarians (N = 17; 101.9 ± 1.9 years) were monitored for 15 min at rest (seated, without moving or talking) to measure RR intervals, from which HRV was evaluated. Our results showed a clear decrease with age in the main parasympathetic HRV variables, as well as in the standard deviation (SD) of the RR series [SD of normal-to-normal interval (SDNN)] and in low frequency (LF) heart rate (HR) oscillations, although differences between octogenarians and centenarians did not reach statistical significance. In 14 centenarians followed until death, only SDNN showed significant correlation (¿ = 0.536; p = 0.048) with survival prognosis. Additionally, SDNN <19 ms was associated with early mortality (=1 year) in centenarians (Hazard Ratio = 5.72). In conclusion, HRV indices reflecting parasympathetic outflow as well as SDNN and LF all present an age-related reduction, which could be representative of a natural exhaustion of allostatic systems related to age. Moreover, low SDNN values (<19 ms) could be associated with early mortality in centenarians. HRV seems to play a role in exceptional longevity, which could be accounted for by centenarians’ exposome.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Assessment of automatic strategies for combining QRS detections by multiple algorithms in multiple leads

  • Llamedo Mariano
  • Martínez Cortés, Juan Pablo
Objective: To develop and evaluate an algorithm for the selection of the best-performing QRS detections from multiple algorithms and ECG leads. Approach: The detections produced by several publicly available single-lead QRS detectors are segmented in 20 s consecutive windows; then a statistical model is trained to estimate a quality metric that is used to rank each 20 s segment of detections. The model describes each heartbeat in terms of six features calculated from the RR interval series, and one feature proportional to the number of heartbeats detected in other leads in a neighborhood of the current heartbeat. With the highest ranked segments, we defined several lead selection strategies (LSS) that were evaluated in a set of 1754 ECG recordings from 14 ECG databases. The LSS proposed were compared with simple strategies such as selecting lead II or the first lead available in a recording. The performance was calculated in terms of the average sensitivity, positive predictive value, and F score. Main results: The best-performing LSS, based on wavedet algorithm, achieved an F score of 98.7, with sensitivity S¿¿=¿¿99.2 and positive predictive value P¿¿=¿¿98.3. The F score for the simpler strategy using the same algorithm was 92.7. The LSS studied in this work have been made available in an open-source toolbox to ease the reproducibility and result comparison. Significance: The results suggest that the use of LSS is convenient for purposes of selecting the best heartbeat locations among those provided by different detectors in different leads, obtaining better results than any of the algorithms individually.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Minimally invasive system to reliably characterize ventricular electrophysiology from living donors

  • Oliván-Viguera, A.
  • Pérez-Zabalza, M.
  • García-Mendívil, L.
  • Mountris, K.A.
  • Orós-Rodrigo, S.
  • Ramos-Marquès, E.
  • Vallejo-Gil, J.M.
  • Fresneda-Roldán, P.C.
  • Fañanás-Mastral, J.
  • Vázquez-Sancho, M.
  • Matamala-Adell, M.
  • Sorribas-Berjón, F.
  • Bellido-Morales, J.A.
  • Mancebón-Sierra, F.J.
  • Vaca-Núñez, A.S.
  • Ballester-Cuenca, C.
  • Marigil, M.Á.
  • Pastor, C.
  • Ordovás, L.
  • Köhler, R.
  • Diez, E.
  • Pueyo, E.
Cardiac tissue slices preserve the heterogeneous structure and multicellularity of the myocardium and allow its functional characterization. However, access to human ventricular samples is scarce. We aim to demonstrate that slices from small transmural core biopsies collected from living donors during routine cardiac surgery preserve structural and functional properties of larger myocardial specimens, allowing accurate electrophysiological characterization. In pigs, we compared left ventricular transmural core biopsies with transmural tissue blocks from the same ventricular region. In humans, we analyzed transmural biopsies and papillary muscles from living donors. All tissues were vibratome-sliced. By histological analysis of the transmural biopsies, we showed that tissue architecture and cellular organization were preserved. Enzymatic and vital staining methods verified viability. Optically mapped transmembrane potentials confirmed that action potential duration and morphology were similar in pig biopsies and tissue blocks. Action potential morphology and duration in human biopsies and papillary muscles agreed with published ranges. In both pigs and humans, responses to increasing pacing frequencies and ß-adrenergic stimulation were similar in transmural biopsies and larger tissues. We show that it is possible to successfully collect and characterize tissue slices from human myocardial biopsies routinely extracted from living donors, whose behavior mimics that of larger myocardial preparations both structurally and electrophysiologically.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Commentary: Increased Beat-to-Beat Variability of T-Wave Heterogeneity Measured From Standard 12-Lead Electrocardiogram Is Associated With Sudden Cardiac Death: A Case-Control Study

  • Chauhan, V.S.
  • Martínez, J.P.
  • van der Heyden, M.A.G.
The electrocardiogram (ECG) reflects the electrical activity within the heart. Following the discovery of the small electrical signals in the human heart, the Dutch scientist Willem Einthoven developed sensitive methods for detecting them and recognized their clinical implications (Kligfield, 2002). For his contributions Willem Einthoven, whose scientific roots originated from the Utrecht physiology department (Einthoven, 1885), was awarded the Nobel Prize in 1924. Since then, many enigmas of the ECG have been solved and its intricate information carries valuable clues for clinical decision making. In vivo mapping studies have established that spatial heterogeneity in repolarization is a requisite for re-entrant ventricular arrhythmias by effecting unidirectional conduction block. Important modulators of spatial heterogeneity of repolarization include autonomic tone, ischemia, heart rate and premature or ectopic beats, which can produce temporal heterogeneity in the order of seconds, minutes, or hours depending on their time-constants. In the contemporary era of dynamic surface electrocardiography, a formidable challenge is quantifying spatiotemporal repolarization heterogeneity with sufficient fidelity to image the arrhythmogenic myocardial substrate and thereby provide indices for a patient’s risk of arrhythmic death (Laguna et al., 2016). Hekkanen et al. (2020) performed a large case-control study of 200 victims...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of t wave amplitude, duration and morphology changes during hemodialysis: Relationship with serum electrolyte levels and heart rate

  • Bukhari, Syed Hassaan Ahmed
  • Palmieri, Flavio
  • Ramírez, Julia
  • Laguna, Pablo
  • Ruiz, José Esteban
  • Ferreira, Dina
  • Potse, Mark
  • Sánchez, Carlos
  • Pueyo, Esther
Objective: Chronic kidney disease affects more than 10% of the world population. Changes in serum ion concentrations increase the risk for ventricular arrhythmias and sudden cardiac death, particularly in end stage renal disease (ESRD) patients. We characterized how T wave amplitude, duration and morphology descriptors change with variations in serum levels of potassium and calcium and in heart rate, both in ESRD patients and in simulated ventricular fibers. Methods: Electrocardiogram (ECG) recordings from twenty ESRD patients undergoing hemodialysis (HD) and pseudo-ECGs (pECGs) calculated from twenty-two simulated ventricular fibers at varying transmural heterogeneity levels were processed to quantify T wave width (Tw), T wave slope-to-amplitude ratio (TS/A) and four indices of T wave morphological variability based on time warping (dw, dNLw, da and dNLa). Serum potassium and calcium levels and heart rate were measured along HD. Results: dNL with serum potassium, dw with calcium and da with heart rate, after correction for covariates. Median values of partial correlation coefficients were 0.75,−0.74 and −0.90, respectively. For all analyzed T wave descriptors, high inter-patient variability was observed in the pattern of such relationships. This variability, accentuated during the first HD time points, was reproduced in the simulations and shown to be influenced by differences in transmural heterogeneity. Conclusion: Changes in serum potassium and calcium levels and in heart rate strongly affect T wave descriptors, particularly those quantifying morphological variability. Significance: ECG markers have the potential to be used for monitoring serum ion concentrations in ESRD patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A Novel Paradigm for in Silico Simulation of Cardiac Electrophysiology Through the Mixed Collocation Meshless Petrov-Galerkin Method

  • Mountris, K.A.
  • Sanchez, C.
  • Pueyo, E.
Multi-scale cardiac electrophysiological modeling involves high computational load due to the inherent complexity as well as to limitations of the employed numerical methods (e.g., Finite Element Method - FEM). This study investigates the use of the Meshless Local Petrov-Galerkin Mixed Collocation (MLPG-MC) method to simulate cardiac electrophysiology. MLPG-MC is a truly meshless method where both the unknown function and its gradient are interpolated using nodal collocation. A 3 cm × 3 cm human ventricular tissue was simulated based on the monodomain reaction-diffusion model using the operator splitting technique. MLPG-MC or FEM were used to solve the diffusion term and the O''Hara-Virág-Varró-Rudy AP model to represent cellular electrophysiology at baseline and under 30% IKr inhibition (IKr30). Mean differences between MLPG-MC and FEM in AP duration at 90% (APD90), 50% (APD50) and 20% (APD20) repolarization levels were 4.47%, 4.16% and 3.29% for baseline conditions and 3.66%, 2.10% and 1.62% for IKr30 conditions. The computational time associated with each of the two methods was comparable. In conclusion, considering that MLPG-MC does not involve any mesh requirements and is well suited for massive parallelization, this study shows that it represents a promising alternative to FEM for cardiac electrophysiology simulations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Response of Ventricular Repolarization to Simulated Microgravity Measured by Periodic Repolarization Dynamics Using Phase-Rectified Signal Averaging

  • Palacios, S.
  • Caiani, E.G.
  • Pueyo, E.
  • Martínez, J.P.
Head-Down Bed Rest (HDBR) microgravity simulation induces cardiovascular deconditioning, including effects on ventricular repolarization. The index of Periodic Repolarization Dynamics (PRD) was developed to quantify low-frequency oscillations of cardiac repolarization. In this study, PRD was quantified by Phase Rectified Signal Averaging (PRDPRSA) and Continuous Wavelet Transform (PRDCWT) methods. PRD was analyzed in ECGs from 22 volunteers at rest and during orthostatic Tilt-Table Test (TTT) performed before and after -6° 60-days HDBR. Significant correlation was found between PRD measured by PRSA and CWT (Pearson''s ¿ = 0.93, p < 10-54 and Kendall''s t = 0.79 p < 10-38). A highly significant increase was found when PRDPRSA values were measured at POST-HDBR with respect to PRE-HDBR in the tilt phase: 1.40 [1.10] deg and 0.97 [0.90] deg (median [IQR]), p = 0.008, respectively. PRDPRSA also increased significantly in the tilt phase with respect to baseline, both at POST-HDBR (0.90 [0.57] deg, p = 0.003) and at PRE-HDBR (0.75 [0.45] deg, p = 0.011). PRD, either measured with PRSA or with CWT, is able to measure changes in ventricular repolarization induced by microgravity simulation as well as following sympathetic provocation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmogram Signal Morphology-Based Stress Assessment

  • Rinkevicius, M.
  • Kontaxis, S.
  • Gil, E.
  • Bailon, R.
  • Lázaro, J.
  • Laguna, P.
  • Marozas, V.
Stress is a healthy natural response to a perceived or actual threat. However, when stress is persistent, it may decrease work productivity, increase the risk of diseases, and affect the quality of life. Stress is reflected in physiological variables, such as heart rate, blood pressure, and pulse wave velocity among others. A photoplethys-mogram (PPG) contains information related to pulse rate and blood pressure. This study analyses parameters derived from PPG signal morphology for mental stress assessment.A low-complexity algorithm is designed using bandpass filtered higher-order derivatives of the PPG signal for estimation of six morphological parameters: the forward pulse wave amplitude A1, the systole and diastole durations T1 and Td, the time delays of reflected waves T12 and T13 from the renal and iliac sites in the central arteries, and the pulse duration Tp. The parameters were investigated on a set of 18 healthy subjects by using a modified Trier Social Stress Test.The results show that the most sensitive PPG morphology parameters to mental stress are the amplitude of forward wave A1, the duration of diastole Td, the time delay of the reflected wave T13, and the pulse-to-pulse interval Tp.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Influence of the Stimulation Current on the Differences between Cell and Tissue Electrophysiological Simulations

  • Monasterio, V.
  • Pueyo, E.
  • Rodríguez-Matas, J.F.
  • Carro, J.
This study compares stimulation waveforms for single-cell simulations. The alternatives include monophasic and biphasic current pulses, and a new waveform that resembles the transmembrane current responsible for conduction in tissue. Results indicate that the new stimulation produces the lowest mismatch between action potential markers simulated in cell and in tissue. In comparison with the monophasic stimulation, the new stimulation reduced cell-fiber differences by 99% for triangulation, by 95% for maximum transmembrane voltage, and by 76% for the maximum voltage slope. In conclusion, the new stimulation waveform could help to improve the trustworthiness of single-cell simulations in studies involving tissue-derived markers.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effect of the Heart Rate Variability Representations on the Quantification of the Cardiorespiratory Interactions during Autonomic Nervous System Blockade

  • Morales, J.F.
  • Bolea, J.
  • Van Huffel, S.
  • Bailón, R.
  • Varon, C.
The Heart Rate Variability (HRV) is a noninvasive tool to evaluate the activity of the autonomic nervous system. To study the HRV, different mathematical representations can be used. The selection of a representation might have an effect on the evaluation of the mechanisms that modulate the Heart Rate (HR). One of these mechanisms is the Respiratory Sinus Arrhythmia (RSA), i.e. an increased HR during inhalation and a decreased HR during exhalation. Different methods exist to quantify the RSA. A common approach is to calculate the power in the High Frequency (HF, 0.15 - 0.4 Hz) band of the spectrum of the HRV representation. More recently proposed methods use the respiratory signals to estimate the strength of the RSA.This paper studies the effect of the HRV representations on the quantification of the RSA. To this end, an experiment is used in which the sympathetic and parasympathetic branches of the autonomic nervous system are selectively blocked. Three different HRV representations are considered. Afterwards, the strength of the RSA is estimated using three approaches, namely the spectral content in the HF band of the HRV representations, orthogonal subspace projections and a time-frequency representation.The results suggest that the selection of an HRV representation does not have a significant impact on the RSA estimates in a healthy population.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Heart Rate Variability Monitoring Using a Wearable Armband

  • Lázaro, J.
  • Reljin, N.
  • Noh, Y.
  • Laguna, P.
  • Chon, K.H.
A wearable electrocardiogram (ECG) monitor is evaluated as heart rate variability (HRV) monitor. The device consists of an armband designed to be worn on the left upper arm which provides 3 ECG channels based on 3 pairs of dry (no hydrogel) electrodes. Armband-ECG and conventional-Holter-ECG signals were simultaneously recorded from 14 subjects during 5 minutes in supine position. Spacial principal component analysis was used to obtain a unique armband ECG signal in which the electromyogram contribution is attenuated. QRS complexes were automatically detected. Five traditional HRV parameters were derived: SDNN, RMSSD, pNN50, and powers within low frequency (LF, [0.04, 0.15] Hz) and high frequency (HF, [0.15, 0.4] Hz) bands. The Pearson''s correlation coefficient between the measurements from the armband device and the measures from the Holter device was computed. Results show very high correlations (1.0000, 0.9999, 0.9984, 1.0000, and 0.9999 for SDNN, RMSSD, pNN50, and powers at LF and HF, respectively), suggesting that the quality of armband-ECG signals is enough to estimate HRV parameters during stationary movement restricted conditions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Heart Rate Variability Analysis Assessment for Asthma Control Stratification

  • Milagro, J.
  • Soto, L.
  • Giner, J.
  • Varon, C.
  • Laguna, P.
  • Plaza, V.
  • Gil, E.
  • Bailón, R.
Autonomic nervous system (ANS) has been suggested to play a major role in the pathogenesis of asthma. This hypothesis has motivated large research, revealing a reduced modulation of the heart rate in subjects with uncontrolled asthma, when compared to asthmatics with controlled symptomatology. In this work, we assessed ANS activity through heart rate variability analysis in a group of asthmatics classified attending to the control of their symptoms. This information was later used for training a logistic regression classifier aiming at differentiating between the levels of control in asthmatic patients. The accuracy of the classifier improved when including ANS information (71.77%, versus 64.73% when only clinical parameters were considered), suggesting that ANS assessment could contribute to better non-invasive asthma monitoring.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

T-Wave Morphology Changes as Surrogate for Blood Potassium Concentration in Hemodialysis Patients

  • Palmieri, F.
  • Ramírez, J.
  • Laguna, P.
  • Gomis, P.
  • Ferreira, D.
  • Ruiz, J.E.
  • Bergasa, B.
  • Martín-Yebra, A.
  • Bukhari, H.A.
  • Pueyo, E.
  • Martínez, J.P.
End-stage renal disease (ESRD) patients undergoing hemodialysis (HD) are at high risk of arrhythmias and sudden cardiac death as a result of blood potassium concentration ([K+ ]) changes. The aim of this study is to investigate if dw, a time-warping-based electrocardiogram (ECG) biomarker of T-wave morphology changes, reflects [K+] evolution in HD patients, facilitating noninvasive [K+] monitoring and avoiding in-hospital blood tests analysis. 48-hour ECGs and a set of hourly-collected blood samples from 12 ESRD patients were acquired and analyzed. dw was calculated between a reference T-wave, measured at the end of the HD session, and the T-waves corresponding to each hour along the whole HD session, when [K+] was measured from blood samples. The values of dw correlated with the relative variations in [K+] with respect to the reference value (end of HD, ¿[K+ ]), with a median (interquartile) correlation coefficient of 0.90 (0.30), evidencing a strong relation between them. Our findings support the use of dw as a surrogate of ¿[K+], suggesting a potential use of dw for non-invasive hyperkalemia monitoring both in hospital and ambulatory settings.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Transmural Ventricular Heterogeneities Play a Major Role in Determining T-Wave Morphology at Different Extracellular Potassium Levels

  • Bukhari, H.A.
  • Palmieri, F.
  • Ferreira, D.
  • Potse, M.
  • Ramírez, J.
  • Laguna, P.
  • Sánchez, C.
  • Pueyo, E.
End-stage renal disease (ESRD) affects more than 10% of the world population. ESRD patients present impaired potassium homeostasis, which increases the risk for ventricular arrhythmias and sudden cardiac death. Noninvasive estimation of serum potassium, [K+], before the patient experiences serious consequences is of major importance. In this study, we investigated the relationship of [K+] with three T-wave morphological descriptors: the T-wave width (Tw), slope-to-amplitude ratio (TSA) and temporal morphological variability (dw) from ECGs of 12 ESRD patients undergoing hemodialysis and from simulated ECGs. Spearman''s correlation coefficients between the descriptors Tw, TSA and dw and [K+] were -0.5, 0. 8 and 0.65, respectively. These associations were, however, highly patient-dependent. The high inter-individual variability in T-wave morphology, particularly observed at high [K+], was reproduced in the simulations and could be explained by differences in transmural heterogeneities, with 10% variations in the proportion of midmyocardial cells leading to changes larger than 15% in T-wave morphology. In conclusion, T-wave morphological descriptors have the potential to be used as predictors of [K+] in ESRD patients, but their associated inter-individual variability should be taken into account, especially under hyperkalemic conditions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Cardiovascular Changes Induced by Acute Emotional Stress Estimated from the Pulse Transit Time Difference

  • Armañac, P.
  • Kontaxis, P.
  • Lázaro, J.
  • Laguna, P.
  • Bailón, R.
  • Gil, E.
In the present work, the difference between arrival times of photoplethysmographic (PPG) pulses from two different sites of the arterial tree (PTTD) is calculated. As the PTTD is considered to be related with arterial pulse wave velocity, an evaluation of it''s usefulness to identify states of acute mental stress is performed. A subset of fourteen healthy volunteers undergoing a stress protocol was analysed and a statistical test was carried out to evaluate the validity of the proposed method. The results showed that the standard deviation of the PTTD had sufficient statistical capacity to discern between states of stress and relaxation. Furthermore, a generalised descending trend of the mean PTTD can be seen from relaxation to stress.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic Nervous System Response to Heat Stress Exposure by Means of Heart Rate Variability

  • Kontaxis, S.
  • Bailon, R.
  • Rapalis, A.
  • Brazaitis, M.
  • Cernych, M.
  • Lazaro, J.
  • Laguna, P.
  • Gil, E.
  • Marozas, V.
In this study, a heart rate variability (HRV) analysis guided by respiration is conducted to assess changes in autonomic nervous system (ANS) regulation during pronounced heat stress induced by repetitive exposures to dry sauna in 13 young healthy subjects. The spectral power at the low frequency (LF) band [0.04, 0.15] Hz and at the high frequency band centered around the mean respiratory rate, estimated from ECG-derived respiration signals, are studied. The mean heart rate (HR), the total power of HRV, and the normalized LF power are also analyzed.Results show that mean HR and normalized LF power increase significantly after basal stage, not only during the sauna sessions, but also at the intermediate short rest stages and recovery phase after 30 min. A significant reduction in the total power of HRV during all sauna sessions is observed, while an increased power in LF band is shown only during recovery which might be related to improved cardiac function (increased cardiac output and reduced peripheral vascular resistance) after heat exposure. Respiratory rate does not change significantly during the protocol but a negative trend at stress stages may indicate a reverse reaction against an over-activation of the sympathetic branch. In conclusion, exposure to heat stress shifts sympathovagal balance of ANS toward sympathetic dominance that increases HR and diminishes HRV.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cardiorespiratory Coupling in Asthmatic Children

  • Milagro, J.
  • Gracia, J.
  • Seppä, V.P.
  • Karjalainen, J.
  • Paassilta, M.
  • Orini, M.
  • Gil, E.
  • Bailón, R.
  • Viik, J.
The relationship between cardiac and respiratory autonomic control has been suggested to be altered in several respiratory disorders. However, and despite the increasing prevalence of asthma, there are not studies assessing the cardiorespiratory coupling (CRC) with respect to the asthmatic status. Since altered autonomic control has been suggested to play a major role in asthma, in this work overnight CRC was assessed in a group of 67 children who underwent a three-month inhaled corticosteroids treatment. After treatment completion, CRC was reduced (p < 0.005) in the subjects without or with a low risk of asthma, whereas it kept unchanged in those with a worse prognosis, suggesting that an altered interaction between cardiac and respiratory activity might be related with an increased risk of asthma.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Acute stress state classification based on electrodermal activity modeling

  • Greco, A.
  • Valenza, G.
  • Lázaro, J.
  • Garzón-Rey, J. M.
  • Aguiló, J.
  • De la Cámara, C.
  • Bailón, Raquel
  • Scilingo, Enzo Pascuale
Acute stress is a physiological condition that may induce several neural dysfunctions with a significant impact on life quality. Accordingly, it would be important to monitor stress in everyday life unobtrusively and inexpensively. In this paper, we presented a new methodological pipeline to recognize acute stress conditions using electrodermal activity (EDA) exclusively. Particularly, we combined a rigorous and robust model (cvxEDA) for EDA processing and decomposition, with an algorithm based on a support vector machine to classify the stress state at a single- subject level. Indeed, our method, based on a single sensor, is robust to noise, applies a rigorous phasic decomposition, and implements an unbiased multiclass classification. To this end, we analyzed the EDA of 65 volunteers subjected to different acute stress stimuli induced by a modified version of the Trier Social Stress Test. Our results show that stress is successfully detected with an average accuracy of 94.62%. Besides, we proposed a further 4-class pattern recognition system able to distinguish between non-stress condition and three different stressful stimuli achieving an average accuracy as high as 75.00%. These results, obtained under controlled conditions, are the first step towards applications in ecological scenarios.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Atrial Dyssynchrony Measured by Strain Echocardiography as a Marker of Proarrhythmic Remodeling and Oxidative Stress in Cardiac Surgery Patients

  • Sanchez, F.J.
  • Gonzalez, V.A.
  • Farrando, M.
  • Baigorria Jayat, A.O.
  • Segovia-Roldan, M.
  • Garciá-Mendívil, L.
  • Ordovás, L.
  • Prado, N.J.
  • Pueyo, E.
  • Diez, E.R.
Aging leads to structural and electrophysiological changes that increase the risk of postoperative atrial arrhythmias; however, noninvasive preoperative markers of atrial proarrhythmic conditions are still needed. This study is aimed at assessing whether interatrial dyssynchrony determined using two-dimensional speckle tracking echocardiography relates to proarrhythmic structural and functional remodeling. A cohort of 45 patients in sinus rhythm referred for cardiac surgery was evaluated by echocardiography and surface electrocardiogram the day before the intervention. Transmembrane potential, connexin, and potassium channel distribution, inflammatory, and nitrooxidative markers were measured from right atrial tissue obtained from patients. A difference greater than 40 milliseconds between right and left atrial free wall contraction confirmed the presence of interatrial dyssynchrony in 21 patients. No difference in relation with age, previous diseases, and 2-dimensional echocardiographic findings as well as average values of global longitudinal right and left atrial strain were found between synchronic and dyssynchronic patients. Postoperative atrial fibrillation incidence increased from 8.3% in the synchronic group to 33.3% in the dyssynchronic ones. P wave duration showed no difference between groups. Action potentials from dyssynchronous patients decreased in amplitude, maximal rate of depolarization, and hyperpolarized. Duration at 30% of repolarization increased, being markedly shorter at 90% of repolarization. Only the dyssynchronous group showed early and delayed afterdepolarizations. Atrial tissue of dyssynchronous patients displayed lateralization of connexin 40 and increased connexin 43 expression and accumulation of tumor necrosis factor-a in the intercalated disc. Tumor necrosis factor-a did not colocalize, however, with lateralized connexin 40. Nitroxidative marks and KATP channels increased perivascularly and in myocytes. Our results demonstrate that, as compared to a traditional surface electrocardiogram, the novel noninvasive echocardiographic evaluation of interatrial dyssynchrony provides a better identification of nonaged-related proarrhythmic atrial remodeling with increased susceptibility to postoperative atrial fibrillation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Otros (Other)

Excitable dynamics in neural and cardiac systems

  • Barrio, R.
  • Coombes, S.
  • Desroches, M.
  • Fenton, F.
  • Luther, S.
  • Pueyo, E.
The application of mathematics, physics and engineering to medical research is continuously growing; interactions among these disciplines have become increasingly important and have contributed to an improved understanding of clinical and biological phenomena, with implications for disease prevention, diagnosis and treatment. This special issue presents examples of this synergy, with a particular focus on the investigation of cardiac and neural excitability. This issue includes 24 original research papers and covers a broad range of topics related to the physiological and pathophysiological function of the brain and the heart. Studies span scales from isolated neurons and small networks of neurons to whole-organ dynamics for the brain and from cardiac subcellular domains and cardiomyocytes to one-dimensional tissues for the heart. This preface is part of the Special Issue on “Excitable Dynamics in Neural and Cardiac Systems”.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Multivariable relationships between autonomic nervous system related indices in hyperbaric environments

  • Perez-Martinez, C.
  • Pelaez-Coca, M.D.
  • Hernando, A.
  • Gil, E.
  • Sanchez, C.
The main aim of this work is to model the relationships between parameters extracted from the heart rate variability (HRV) signal, which is derived from the electrocardiogram (ECG), at different stages of a simulated immersion in a hyperbaric chamber. The response of the Autonomic Nervous System is known to be affected by changes in atmospheric pressure, reflected in changes in the HRV signal. A dataset consisting of ECG signals from 17 subjects exposed to a controlled hyperbaric environment, simulating depths from 0 m to 40 m, was used. Both linear and nonlinear dependences of HRV parameters were analysed using linear regression and Mutual Information (entropy-based) techniques. Furthermore, relationships between parameters of the HRV signals, biophysical variables of the subjects, and atmospheric pressure changes were characterized by artificial neural networks. In particular, self-organizing maps (SOM) were trained for modelling and clustering all the data. In the mid-term, these models could be the basis to create predictive models of HRV parameters at high depths in order to increase the safety for divers by warning them if some abnormal body response could be expected just by processing the ECG signal at sea level before immersion.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmographic Waveform in Hyperbaric Environment

  • Pelaez Coca, M.D.
  • Hernando, A.
  • Sanchez, C.
  • Lozano Albalate, M.T.
  • Izquierdo, D.
  • Gil, E.
The objective of this work is the identification of significant variations of morphological parameters of the photoplethysmographic (PPG) signal when the subjects are exposed to an increase in atmospheric pressure. To achieve this goal, the PPG signal of 26 subjects, exposed to a hyperbaric environment whose pressure increases up to 5 atm, has been recorded. From this record, segments of 4 minutes have been processed at 1 atm, 3 atm and 5 atm, both in the descending (D) and ascending (A) periods of the immersion. In total, four states (3D, 5, 3A and 1A) normalized to the basal state (1D) have been considered. In these segments, six morphological parameters of the PPG signal were studied. The width, the amplitude, the widths of the anacrotic and catacrotic phases, and the upward and downward slopes of each PPG pulse were extracted. The results showed significant increases in the three parameters related to the pulse width. This increase is significant in the four states analysed for the anacrotic phase width. Furthermore, a significant decrease in the amplitude and in both slopes (in the states 1A) was observed. These results show that the PPG width responds rapidly to the increase in pressure, indicating an activation of the sympathetic system, while amplitude and pulse slopes are decreased when the subjects are exposed to the hyperbaric environment for a considerable period of time.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effect of yoga on pulse rate variability measured from a venous pressure waveform

  • Hernando, D.
  • Nardelli, M.
  • Hocking, K.
  • Lazaro, J.
  • Alvis, B.
  • Gil, E.
  • Scilingo, E.P.
  • Brophy, D.R.
  • Valenza, G.
  • Laguna, P.
  • Brophy, C.
  • Bailon, R.
The benefits of yoga have been studied in different fields, from chronic health conditions to mental disorders, showing that it can help to improve the overall health. In particular, it has been proven that yoga also improves the autonomic function. Heart rate variability (HRV) at rest is commonly used as a non-invasive measure of autonomic regulation of heart rate. Alternatively, pulse rate variability (PRV) has been proposed as a surrogate of HRV. VoluMetrix has developed a novel technology that captures venous waveforms via sensors on the volar aspect of the wrist, called NIVAband. This study aims to assess the effect of yoga in the autonomic nervous system by analyzing the PRV obtained from the NIVA signal. Temporal (statistics of the normal-to-normal intervals), spectral (power in low and high frequency bands) and nonlinear (lagged Poincaré Plot analysis) parameters are analyzed before and after a yoga session in 20 healthy volunteers. The PRV analysis shows an increase in parameters related to parasympathetic activity and overall variability, and a decrease in parameters related to sympathetic activity and mean heart rate. These results support the beneficial effect of yoga in autonomic nervous system, increasing the parasympathetic activity.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of Spatiooral Cardiac Action Potential Variability at Baseline and under ß-Adrenergic Stimulation by Combined Unscented Kalman Filter and Double Greedy Dimension Reduction

  • Sampedro-Puente, D.A.
  • Raphel, F.
  • Fernandez-Bes, J.
  • Laguna, P.
  • Lombardi, D.
  • Pueyo, E.
Objective: Elevated spatiooral variability of human ventricular repolarization has been related to increased risk for ventricular arrhythmias and sudden cardiac death, particularly under ß-adrenergic stimulation (ß-AS). This work presents a methodology for theoretical characterization of temporal and spatial repolarization variability at baseline conditions and in response to ß-AS. For any measured voltage trace, the proposed methodology estimates the parameters and state variables of an underlying human ventricular action potential (AP) model by combining Double Greedy Dimension Reduction (DGDR) with automatic selection of biomarkers and the Unscented Kalman Filter (UKF). Such theoretical characterization can facilitate subsequent characterization of underlying variability mechanisms. Material and Methods: Given an AP trace, initial estimates for the ionic conductances in a stochastic version of the baseline human ventricular O'Hara et al. model were obtained by DGDR. Those estimates served to initialize and update model parameter estimates by the UKF method based on formulation of an associated nonlinear state-space representation and joint estimation of model parameters and state variables. Similarly, ß-AS-induced phosphorylation levels of cellular substrates were estimated by the DGDR-UKF methodology. Performance was tested by building an experimentally-calibrated population of virtual cells, from which synthetic AP traces were generated for baseline and ß-AS conditions. Results: The combined DGDR-UKF methodology led to 25% reduction in the error associated with estimation of ionic current conductances at baseline conditions and phosphorylation levels under ß-AS with respect to individual DGDR and UKF methods. This improvement was not at the expense of higher computational load, which was diminished by 90% with respect to the individual UKF method. Both temporal and spatial AP variability of repolarization were accurately characterized by the DGDR-UKF methodology. Conclusions: A combined DGDR-UKF methodology is proposed for parameter and state variable estimation of human ventricular cell models from available AP traces at baseline and under ß-AS. This methodology improves the estimation performance and reduces the convergence time with respect to individual DGDR and UKF methods and renders a suitable approach for computational characterization of spatiooral repolarization variability to be used for ascertainment of variability mechanisms and its relation to arrhythmogenesis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Omnipolar EGM voltage mapping for atrial fibrosis identification evaluated with an electrophysiological model

  • Riccio, J.
  • Alcaine, A.
  • Rocher, S.
  • Laguna, P.
  • Saiz, J.
  • Martínez, J.P.
Atrial fibrillation (AF) is the most spread heart arrhythmia, whose mechanisms are not completely clear yet. Catheter ablation is a standard treatment, which isolates the area involved in the arrhythmia. Intracardiac electrograms (EGMs) are used to better understand the AF mechanisms and to find appropriate ablation sites. Bipolar EGMs (b-EGMs) are often employed, but their amplitude and shape depend on catheter orientation, limiting reliability. To avoid this uncertainty, an approach insensitive to catheter orientation, referred as Omnipolar EGM (OP-EGM) method, has been introduced, which uses an estimation of the electric field within a group of electrodes, referred as clique. In this work, we compare different mapping approaches based on b-EGMs and OP-EGM signals in simulation including fibrosis, so to evaluate their ability to detect fibrosis and reproduce the spatial distribution of the voltage. Maps have been computed using two clique configurations (square and triangular), introducing or not a previous time alignment of the b-EGMs. OP-EGM signals have been obtained by projecting the electric field along directions of its maximal excursion and its principal components. Results show that the proposed alignment of b-EGMs improves maps based on OP-EGM signals. Both cliques configurations present good performance, in terms of fibrosis detection and correlation with the reference voltage maps.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Unipolar Electrogram Eigenvalue Distribution Analysis for the Identification of Atrial Fibrosis

  • Riccio, Jennifer
  • Rocher Ventura, Sara
  • Martínez Mateu, Laura
  • Alcaine Otín, Alejandro
  • Sáiz Rodríguez, Javier
  • Martínez Cortés, Juan Pablo
  • Laguna Lasaosa, Pablo
Atrial fibrosis plays an important role in the pathogenesis of atrial fibrillation (AF). Low bipolar electrograms (b-EGMs) peak-to-peak voltage areas indicate scar tissue and are considered targets for AF substrate ablation. However, this approach ignores the spatiotemporal information embedded in the signal and the dependence of b-EGMs on catheter orientation. This work proposes an approach to detect fibrosis based on the eigenvalue dominance ratio (EIGDR) in an ensemble (clique) of unipolar electrograms (u-EGMs). A 2-D tissue with a central circular patch of fibrosis has been simulated using the Courtemanche cellular model. Maps of EIGDR have been computed using two sizes of electrode cliques, from the original u-EGMs within the ensemble or after a time alignment of these signals. Performance of each map in detecting fibrosis has been evaluated using receiver operating characteristic curves and detection accuracy. Best results achieve an area under the curve (AUC) of 0.98 and an accuracy (ACC) of 1 when we use as marker the gain in eigenvalue dominance produced by the ensemble alignment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Relationship between Atrial Oscillatory Acetylcholine Release Pattern and f-wave Frequency Modulation: a Computational and Experimental Study

  • Celotto, Chiara
  • Sánchez Tapia, Carlos
  • Mountris, Konstantinos
  • Abdollahpur, Mostafa
  • Sandberg, Frida
  • Laguna Lasaosa, Pablo
  • Pueyo Paúles, Esther
The frequency of fibrillatory waves (f-waves), F f , exhibits significant variation over time, and previous studies suggest that some of this variation is related to respiratory modulation through the autonomic nervous system. In this study, we tested the hypothesis that this variation (ΔF f ) could be related to acetylcholine concentration ([ACh]) release pattern. Electrocardiograms were recorded from seven patients during controlled respiration before and after full vagal blockade, from which f-wave frequency modulation was characterized. Computational simulations in human atrial tissues were performed to assess the effects of [ACh] release pattern on F f and compared to experimental results in humans. A cross-stimulation protocol was applied onto the tissue to initiate a rotor while cyclically varying [ACh] following a sinusoidal waveform of frequency equal to 0.125 Hz. Different mean levels (0.05, 0.075μM/l) and peak-to-peak ranges (0.1, 0.05, 0.025 μM/l) of [ACh] variation were tested. In all patients, an f-wave frequency modulation could be observed. In 57% of the patients, this modulation was significantly reduced after vagal blockade. Simulations confirmed that rotor frequency variations followed the induced [ACh] patterns. Mean F f was dependent on mean [ACh] level, whileΔF f was dependent on [ACh] variation range.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Monitoring blood potassium concentration in hemodialysis patients by quantifying T-wave morphology dynamics

  • Palmieri, F.
  • Gomis, P.
  • Ferreira, D.
  • Ruiz, J.E.
  • Bergasa, B.
  • Martín-Yebra, A.
  • Bukhari, H.A.
  • Pueyo, E.
  • Martínez, J.P.
  • Ramírez, J.
  • Laguna, P.
We investigated the ability of time-warping-based ECG-derived markers of T-wave morphology changes in time (dw) and amplitude (da), as well as their non-linear components (dNLw and dNLa), and the heart rate corrected counterpart (dw,c), to monitor potassium concentration ([K+]) changes (Δ[K+]) in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD). We compared the performance of the proposed time-warping markers, together with other previously proposed [K+] markers, such as T-wave width (Tw) and T-wave slope-to-amplitude ratio (TS/A), when computed from standard ECG leads as well as from principal component analysis (PCA)-based leads. 48-hour ECG recordings and a set of hourly-collected blood samples from 29 ESRD-HD patients were acquired. Values of dw, da, dNLw, dNLa and dw,c were calculated by comparing the morphology of the mean warped T-waves (MWTWs) derived at each hour along the HD with that from a reference MWTW, measured at the end of the HD. From the same MWTWs Tw and TS/A were also extracted. Similarly, Δ[K+] was calculated as the difference between the [K+] values at each hour and the [K+] reference level at the end of the HD session. We found that dw and dw,c showed higher correlation coefficients with Δ[K+] than TS/A—Spearman’s (ρ) and Pearson’s (r)—and Tw—Spearman’s (ρ)—in both SL and PCA approaches being the intra-patient median ρ≥0.82 and r≥0.87 in SL and ρ≥0.82 and r≥0.89 in PCA respectively. Our findings would point at dw and dw,c as the most suitable surrogate of Δ[K+], suggesting that they could be potentially useful for non-invasive monitoring of ESRD-HD patients in hospital, as well as in ambulatory settings. Therefore, the tracking of T-wave morphology variations by means of time-warping analysis could improve continuous and remote [K+] monitoring of ESRD-HD patients and flagging risk of [K+]-related cardiovascular events.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Validity of the polar h7 heart rate sensor for heart rate variability analysis during exercise in different age, body composition and fitness level groups

  • Hernández-Vicente, A.
  • Hernando, D.
  • Marín-Puyalto, J.
  • Vicente-Rodríguez, G.
  • Garatachea, N.
  • Pueyo, E.
  • Bailón, R.
This work aims to validate the Polar H7 heart rate (HR) sensor for heart rate variability (HRV) analysis at rest and during various exercise intensities in a cohort of male volunteers with different age, body composition and fitness level. Cluster analysis was carried out to evaluate how these phenotypic characteristics influenced HR and HRV measurements. For this purpose, sixty-seven volunteers performed a test consisting of the following consecutive segments: sitting rest, three submaximal exercise intensities in cycle-ergometer and sitting recovery. The agreement between HRV indices derived from Polar H7 and a simultaneous electrocardiogram (ECG) was assessed using concordance correlation coefficient (CCC). The percentage of subjects not reaching excellent agreement (CCC > 0.90) was higher for high-frequency power (PHF) than for low-frequency power (PLF) of HRV and increased with exercise intensity. A cluster of unfit and not young volunteers with high trunk fat percentage showed the highest error in HRV indices. This study indicates that Polar H7 and ECG were interchangeable at rest. During exercise, HR and PLF showed excellent agreement between devices. However, during the highest exercise intensity, CCC for PHF was lower than 0.90 in as many as 60% of the volunteers. During recovery, HR but not HRV measurements were accurate. As a conclusion, phenotypic differences between subjects can represent one of the causes for disagreement between HR sensors and ECG devices, which should be considered specifically when using Polar H7 and, generally, in the validation of any HR sensor for HRV analysis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Feasibility of atrial fibrillation detection from a novel wearable armband device

  • Bashar, Syed Khairul
  • Hossain, Md-Billal
  • Lázaro Plaza, Jesús
  • Ding, Eric Y.
  • Noh, Yeonsik
  • Cho, Chae Ho
  • McManus, David D.
  • Fitzgibbons, Timothy P.
  • Chon, Ki H.
Background Atrial fibrillation (AF) is the world’s most common heart rhythm disorder and even several minutes of AF episodes can contribute to risk for complications, including stroke. However, AF often goes undiagnosed owing to the fact that it can be paroxysmal, brief, and asymptomatic. Objective To facilitate better AF monitoring, we studied the feasibility of AF detection using a continuous electrocardiogram (ECG) signal recorded from a novel wearable armband device. Methods In our 2-step algorithm, we first calculate the R-R interval variability–based features to capture randomness that can indicate a segment of data possibly containing AF, and subsequently discriminate normal sinus rhythm from the possible AF episodes. Next, we use density Poincaré plot-derived image domain features along with a support vector machine to separate premature atrial/ventricular contraction episodes from any AF episodes. We trained and validated our model using the ECG data obtained from a subset of the MIMIC-III (Medical Information Mart for Intensive Care III) database containing 30 subjects. Results When we tested our model using the novel wearable armband ECG dataset containing 12 subjects, the proposed method achieved sensitivity, specificity, accuracy, and F1 score of 99.89%, 99.99%, 99.98%, and 0.9989, respectively. Moreover, when compared with several existing methods with the armband data, our proposed method outperformed the others, which shows its efficacy. Conclusion Our study suggests that the novel wearable armband device and our algorithm can be used as a potential tool for continuous AF monitoring with high accuracy.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Dynamical analysis of early afterdepolarization patterns in a biophysically detailed cardiac model

  • Barrio Gil, Roberto
  • Martinez Carballo, María Ángeles
  • Pueyo Paules, Esther
  • Serrano Pastor, Sergio
Arrhythmogenic early afterdepolarizations (EADs) are investigated in a biophysically detailed mathematical model of a rabbit ventricular myocyte, providing their location in the parameter phase space and describing their dynamical mechanisms. Simulations using the Sato model, defined by 27 state variables and 177 parameters, are conducted to generate electrical action potentials (APs) for different values of the pacing cycle length and other parameters related to sodium and calcium concentrations. A detailed study of the different AP patterns with or without EADs is carried out, showing the presence of a high variety of temporal AP configurations with chaotic and quasiperiodic behaviors. Regions of bistability are identified and, importantly, linked to transitions between different behaviors. Using sweeping techniques, one-, two-, and three-parameter phase spaces are provided, allowing ascertainment of the role of the selected parameters as well as location of the transition regions. A Devil’s staircase, with symbolic sequence analysis, is proposed to describe transitions in the ratio between the number of voltage (EAD and AP) peaks and the number of APs. To conclude, the obtained results are linked to recent studies for low-dimensional models and a conjecture is made for the internal dynamical structure of the transition region from non-EAD to EAD behavior using fold and cusp bifurcations and maximal canards. In a healthy heart, the sinoatrial node sends out an electrical impulse that spreads throughout the heart activating all cardiac myocytes to produce an electrical response called the action potential (AP). The AP follows a sequence of AP phases corresponding to the inflow and outflow of ions through the membrane of cardiac myocytes. Under some circumstances, that sequence of AP phases can be disrupted by the presence of the so-called early afterdepolarizations (EADs), which are secondary voltage depolarizations that can appear during phase 2 or 3 of the AP. Side effects of drugs, ion channel dysfunction, or oxidative stress, among others, can lead to the genesis of EADs.1–3 In heart failure, long QT syndrome, and other pathological conditions, EADs have been reported to be a relevant cause of fatal ventricular arrhythmias,4–6 but more knowledge is required to understand the theoretical mechanisms underlying their generation. During the last few decades, computational models of cardiac electrical activity have been instrumental in shedding light on various cardiac phenomena, including EADs. Biophysically detailed models of high dimension, i.e., with a large number of state variables, allow more faithful reproduction of experimental observations and facilitate biophysical interpretation. Here, we use the high-dimensional electrophysiological model of a rabbit ventricular myocyte developed by Sato et al.6 with 27 state variables and 177 model parameters. By combining different techniques for dynamical system analysis, we investigate the parameter phase space using three parameters reported to highly influence model dynamics.7 We identify regions in the phase space showing transitions from absence to presence of EADs through different temporal sequences of EADs. In these processes, dynamical phenomena are present, including bistability, chaos, fold, and cusp bifurcations. Putting all this information together and taking into account recent findings using low-dimensional models, we provide a conjecture about the internal dynamical structure of the transition region from absence to presence of EADs in the parameter phase space studied for the Sato model.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

SK Channel Block and Adrenergic Stimulation Counteract Acetylcholine-Induced Arrhythmogenic Effects in Human Atria

  • Celotto, Chiara
  • Sánchez, Carlos
  • Mountris, Konstantinos A.
  • Laguna, Pablo
  • Pueyo, Esther
There is increasing evidence on the role of the autonomic nervous system in the pathogenesis of atrial fibrillation. Interventions targeting autonomic modulation of atrial electrical activity have been shown to reduce the incidence of atrial arrhythmias. Additionally, recent investigations have proved that pharmacological therapies inhibiting small-conductance calcium-activated potassium (SK) channels are able to lessen cholinergic effects in the atria.In this study we use computational modeling and simulation to test individual and combined effects of SK channel block and adrenergic stimulation in counteracting detrimental effects induced by the parasympathetic neurotransmitter acetylcholine (ACh) on human atrial electrophysiology. Cell and tissue models are built that incorporate descriptions of SK channels as well as of isoproterenol (Iso)- and ACh-mediated regulation of the atrial action potential (AP). Three different cellular AP models, representing a range of physiological AP shapes, are considered and both homogeneous and heterogeneous ACh distributions in atrial tissue are simulated.At the cellular level, SK channel block is demonstrated to partially revert shortening of AP duration (APD) mediated by ACh at various doses, whereas 1 µM Iso has a variable response depending on the AP shape. The combination of SK block and Iso is in all cases able to take APD back to baseline levels, recovering between 82% and 120% of the APD shortening induced by 0.1 µM ACh. At the tissue level, SK block and Iso alone or in combination do not exert remarkable effects on conduction velocity, but the combination of the two is able to notably prolong the ACh-mediated APD shortening, thus increasing the wavelength for reentry.In conclusion, the results from this study support the combination of SK channel block and adrenergic stimulation as a potential option to counteract parasympathetically-mediated proarrhythmic effects in the human atria.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cardiopulmonary coupling indices to assess weaning readiness from mechanical ventilation

  • Armañac-Julian, Pablo
  • Hernando, David
  • Lázaro, Jesús
  • Haro, Candelaria de
  • Magrans, Rudys
  • Morales, John
  • Moeyersons, Jonathan
  • Sarlabous, Leonardo
  • López-Aguilar, Josefina
  • Subirà, Carles
  • Fernández, Rafael
  • Orini, Michele
  • Laguna, Pablo
  • Varon, Carolina
  • Gil, Eduardo
  • Bailón, Raquel
  • Blanch, Lluís
The ideal moment to withdraw respiratory supply of patients under Mechanical Ventilation at Intensive Care Units (ICU), is not easy to be determined for clinicians. Although the Spontaneous Breathing Trial (SBT) provides a measure of the patients’ readiness, there is still around 15–20% of predictive failure rate. This work is a proof of concept focused on adding new value to the prediction of the weaning outcome. Heart Rate Variability (HRV) and Cardiopulmonary Coupling (CPC) methods are evaluated as new complementary estimates to assess weaning readiness. The CPC is related to how the mechanisms regulating respiration and cardiac pumping are working simultaneously, and it is defined from HRV in combination with respiratory information. Three different techniques are used to estimate the CPC, including Time-Frequency Coherence, Dynamic Mutual Information and Orthogonal Subspace Projections. The cohort study includes 22 patients in pressure support ventilation, ready to undergo the SBT, analysed in the 24 h previous to the SBT. Of these, 13 had a successful weaning and 9 failed the SBT or needed reintubation –being both considered as failed weaning. Results illustrate that traditional variables such as heart rate, respiratory frequency, and the parameters derived from HRV do not differ in patients with successful or failed weaning. Results revealed that HRV parameters can vary considerably depending on the time at which they are measured. This fact could be attributed to circadian rhythms, having a strong influence on HRV values. On the contrary, significant statistical differences are found in the proposed CPC parameters when comparing the values of the two groups, and throughout the whole recordings. In addition, differences are greater at night, probably because patients with failed weaning might be experiencing more respiratory episodes, e.g. apneas during the night, which is directly related to a reduced respiratory sinus arrhythmia. Therefore, results suggest that the traditional measures could be used in combination with the proposed CPC biomarkers to improve weaning readiness.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Estimation of the second ventilatory threshold through ventricular repolarization profile analysis

  • Milagro, J.
  • Hernández-Vicente, A.
  • Hernando, D.
  • Casajús, J.A.
  • Garatachea, N.
  • Bailón, R.
  • Pueyo, E.
Under the hypothesis that sympathetic control of ventricular repolarization may change once the second ventilatory threshold (VT2) has been reached, a novel methodology for non-invasive VT2 estimation based on the analysis of the T wave from the electrocardiogram (ECG) is proposed, and potential underlying physiological mechanisms are suggested. 25 volunteers (33.4 ± 5.2 years) underwent an incremental power cycle ergometer test (25 W/minute). During the test, respiratory gas exchange and multi-lead ECG were acquired. The former was employed to determine VT2, used here as a reference, whereas the latter was used to compute the temporal profiles of an index of ventricular repolarization instability (dT) and its low-frequency (LF) oscillations (LFdT). The sudden increases observed in dT and LFdT profiles above an established heart rate threshold were employed to derive VT2 estimates, referred to as VT2dT and VT2LFdT, respectively. Estimation errors of -4.7 ± 25.2 W were obtained when considering VT2dT. Errors were lower than the one-minute power increment of 25 W in 68% of the subjects and lower than 50 W in 89.5% of them. When using VT2LFdT, estimation error was of 15.3 ± 32.4 W. Most of the subjects shared common characteristic dT and LFdT profiles, which could be reflecting changes in the autonomic control of ventricular repolarization before and after reaching VT2. The analysis of ventricular repolarization dynamics during exercise allows non-invasive ECG-based estimation of VT2, possibly in relation to changes in the autonomic control of ventricular electrical activity when VT2 is reached.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Location of parasympathetic innervation regions from electrograms to guide atrial fibrillation ablation therapy: an in silico modeling study

  • Celotto, Chiara
  • Sánchez, Carlos
  • Mountris, Konstantinos A.
  • Laguna, Pablo
  • Pueyo, Esther
The autonomic nervous system (ANS) plays an essential role in the generation and maintenance of cardiac arrhythmias. The cardiac ANS can be divided into its extrinsic and intrinsic components, with the latter being organized in an epicardial neural network of interconnecting axons and clusters of autonomic ganglia called ganglionated plexi (GPs). GP ablation has been associated with a decreased risk of atrial fibrillation (AF) recurrence, but the accurate location of GPs is required for ablation to be effective. Although GP stimulation triggers both sympathetic and parasympathetic ANS branches, a predominance of parasympathetic activity has been shown. This study aims was to develop a method to locate atrial parasympathetic innervation sites based on measurements from a grid of electrograms (EGMs). Electrophysiological models representative of non-AF, paroxysmal AF (PxAF), and persistent AF (PsAF) tissues were developed. Parasympathetic effects were modeled by increasing the concentration of the neurotransmitter acetylcholine (ACh) in randomly distributed circles across the tissue. Different circle sizes of ACh and fibrosis geometries were considered, accounting for both uniform diffuse and non-uniform diffuse fibrosis. Computational simulations were performed, from which unipolar EGMs were computed in a 16 × 1 6 electrode mesh. Different distances of the electrodes to the tissue (0.5, 1, and 2 mm) and noise levels with signal-to-noise ratio (SNR) values of 0, 5, 10, 15, and 20 dB were tested. The amplitude of the atrial EGM repolarization wave was found to be representative of the presence or absence of ACh release sites, with larger positive amplitudes indicating that the electrode was placed over an ACh region. Statistical analysis was performed to identify the optimal thresholds for the identification of ACh sites. In all non-AF, PxAF, and PsAF tissues, the repolarization amplitude rendered successful identification. The algorithm performed better in the absence of fibrosis or when fibrosis was uniformly diffuse, with a mean accuracy of 0.94 in contrast with a mean accuracy of 0.89 for non-uniform diffuse fibrotic cases. The algorithm was robust against noise and worked for the tested ranges of electrode-to-tissue distance. In conclusion, the results from this study support the feasibility to locate atrial parasympathetic innervation sites from the amplitude of repolarization wave.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Proposal for a home sleep monitoring platform employing a smart glove

  • Lazazzera, Remo
  • Laguna, Pablo
  • Gil, Eduardo
  • Carrault, Guy
The present paper proposes the design of a sleep monitoring platform. It consists of an entire sleep monitoring system based on a smart glove sensor called UpNEA worn during the night for signals acquisition, a mobile application, and a remote server called AeneA for cloud computing. UpNEA acquires a 3-axis accelerometer signal, a photoplethysmography (PPG), and a peripheral oxygen saturation (SpO2) signal from the index finger. Overnight recordings are sent from the hardware to a mobile application and then transferred to AeneA. After cloud computing, the results are shown in a web application, accessible for the user and the clinician. The AeneA sleep monitoring activity performs different tasks: sleep stages classification and oxygen desaturation assessment; heart rate and respiration rate estimation; tachycardia, bradycardia, atrial fibrillation, and premature ventricular contraction detection; and apnea and hypopnea identification and classification. The PPG breathing rate estimation algorithm showed an absolute median error of 0.5 breaths per minute for the 32 s window and 0.2 for the 64 s window. The apnea and hypopnea detection algorithm showed an accuracy (Acc) of 75.1%, by windowing the PPG in one-minute segments. The classification task revealed 92.6% Acc in separating central from obstructive apnea, 83.7% in separating central apnea from central hypopnea and 82.7% in separating obstructive apnea from obstructive hypopnea. The novelty of the integrated algorithms and the top-notch cloud computing products deployed, encourage the production of the proposed solution for home sleep monitoring.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of Atrial Propagation Patterns and Fibrotic Substrate With a Modified Omnipolar Electrogram Strategy in Multi-Electrode Arrays

  • Riccio, J
  • Alcaine, A
  • Rocher, S
  • Martinez-Mateu, L
  • Laranjo, S
  • Saiz, J
  • Laguna, P
  • Martinez, JP
Introduction: The omnipolar electrogram method was recently proposed to try to generate orientation-independent electrograms. It estimates the electric field from the bipolar electrograms of a clique, under the assumption of locally plane and homogeneous propagation. The local electric field evolution over time describes a loop trajectory from which omnipolar signals in the propagation direction, substrate and propagation features, are derived. In this work, we propose substrate and conduction velocity mapping modalities based on a modified version of the omnipolar electrogram method, which aims to reduce orientation-dependent residual components in the standard approach.</p> & nbsp;</p> Methods: A simulated electrical propagation in 2D, with a tissue including a circular patch of diffuse fibrosis, was used for validation. Unipolar electrograms were calculated in a multi-electrode array, also deriving bipolar electrograms along the two main directions of the grid. Simulated bipolar electrograms were also contaminated with real noise, to assess the robustness of the mapping strategies against noise. The performance of the maps in identifying fibrosis and in reproducing unipolar reference voltage maps was evaluated. Bipolar voltage maps were also considered for performance comparison.</p> & nbsp;</p> Results: Results show that the modified omnipolar mapping strategies are more accurate and robust against noise than bipolar and standard omnipolar maps in fibrosis detection (accuracies higher than 85 vs. 80% and 70%, respectively). They present better correlation with unipolar reference voltage maps than bipolar and original omnipolar maps (Pearson''s correlations higher than 0.75 vs. 0.60 and 0.70, respectively).</p> & nbsp;</p> Conclusion: The modified omnipolar method improves fibrosis detection, characterization of substrate and propagation, also reducing the residual sensitivity to directionality over the standard approach and improving robustness against noise. Nevertheless, studies with real electrograms will elucidate its impact in catheter ablation interventions.</p>
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Periodic repolarization dynamics as predictor of risk for sudden cardiac death in chronic heart failure patients

  • Palacios, Saúl
  • Cygankiewicz, Iwona
  • Bayés de Luna, Antoni
  • Pueyo, Esther
  • Martínez, Juan Pablo
The two most common modes of death among chronic heart failure (CHF) patients are sudden cardiac death (SCD) and pump failure death (PFD). Periodic repolarization dynamics (PRD) quantifies low-frequency oscillations in the T wave vector of the electrocardiogram (ECG) and has been postulated to reflect sympathetic modulation of ventricular repolarization. This study aims to evaluate the prognostic value of PRD to predict SCD and PFD in a population of CHF patients. 20-min high-resolution (1000 Hz) ECG recordings from 569 CHF patients were analyzed. Patients were divided into two groups, PRD+ and PRD-, corresponding to PRD values above and below the optimum cutoff point of PRD in the study population. Univariate Cox regression analysis showed that SCD risk in the PRD+ group was double the risk in the PRD- group [ hazard ratio (95% CI) 2.001 (1.127-3.554), p < 0.05]. The combination of PRD with other Holter-based ECG indices, such as turbulence slope (TS) and index of average alternans (IAA), improved SCD prediction by identifying groups of patients at high SCD risk. PFD could be predicted by PRD only when combined with TS [hazard ratio 2.758 (1.572-4.838), p < 0.001]. In conclusion, the combination of PRD with IAA and TS can be used to stratify the risk for SCD and PFD, respectively, in CHF patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Nonlinear T-Wave Time Warping-Based Sensing Model for Non-Invasive Personalised Blood Potassium Monitoring in Hemodialysis Patients: A Pilot Study

  • Palmieri, Flavio
  • Gomis, Pedro
  • Ruiz, José Esteban
  • Ferreira, Dina
  • Martín-Yebra, Alba
  • Pueyo, Esther
  • Martínez, Juan Pablo
  • Ramírez, Julia
  • Laguna, Pablo
Background: End-stage renal disease patients undergoing hemodialysis (ESRD-HD) therapy are highly susceptible to malignant ventricular arrhythmias caused by undetected potassium concentration ([K+]) variations (Δ[K+]) out of normal ranges. Therefore, a reliable method for continuous, noninvasive monitoring of [K+] is crucial. The morphology of the T-wave in the electrocardiogram (ECG) reflects Δ[K+] and two time-warping-based T-wave morphological parameters, dw and its heart-rate corrected version dw,c, have been shown to reliably track Δ[K+] from the ECG. The aim of this study is to derive polynomial models relating dw and dw,c with Δ[K+], and to test their ability to reliably sense and quantify Δ[K+] values. Methods: 48-hour Holter ECGs and [K+] values from six blood samples were collected from 29 ESRD-HD patients. For every patient, dw and dw,c were computed, and linear, quadratic, and cubic fitting models were derived from them. Then, Spearman’s (ρ) and Pearson’s (r) correlation coefficients, and the estimation error (ed) between Δ[K+] and the corresponding model-estimated values (Δ^[K+]) were calculated. Results and Discussions: Nonlinear models were the most suitable for Δ[K+] estimation, rendering higher Pearson’s correlation (median 0.77 ≤r≤ 0.92) and smaller estimation error (median 0.20 ≤ed≤ 0.43) than the linear model (median 0.76 ≤r≤ 0.86 and 0.30 ≤ed≤ 0.40), even if similar Spearman’s ρ were found across models (median 0.77 ≤ρ≤ 0.83). Conclusion: Results support the use of nonlinear T-wave-based models as Δ[K+] sensors in ESRD-HD patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Machine learning enables noninvasive prediction of atrial fibrillation driver location and acute pulmonary vein ablation success using the 12-lead ECG

  • Luongo, Giorgio
  • Azzolin, Luca
  • Schuler, Steffen
  • Rivolta, Massimo W.
  • Almeida, Tiago P.
  • Martínez, Juan P.
  • Soriano, Diogo C.
  • Luik, Armin
  • Müller-Edenborn, Björn
  • Jadidi, Amir
  • Dössel, Olaf
  • Sassi, Roberto
  • Laguna, Pablo
  • Loewe, Axel
Background: Atrial fibrillation (AF) is the most common supraventricular arrhythmia, characterized by disorganized atrial electrical activity, maintained by localized arrhythmogenic atrial drivers. Pulmonary vein isolation (PVI) allows to exclude PV-related drivers. However, PVI is less effective in patients with additional extra-PV arrhythmogenic drivers. Objectives: To discriminate whether AF drivers are located near the PVs vs extra-PV regions using the noninvasive 12-lead electrocardiogram (ECG) in a computational and clinical framework, and to computationally predict the acute success of PVI in these cohorts of data. Methods: AF drivers were induced in 2 computerized atrial models and combined with 8 torso models, resulting in 1128 12-lead ECGs (80 ECGs with AF drivers located in the PVs and 1048 in extra-PV areas). A total of 103 features were extracted from the signals. Binary decision tree classifier was trained on the simulated data and evaluated using hold-out cross-validation. The PVs were subsequently isolated in the models to assess PVI success. Finally, the classifier was tested on a clinical dataset (46 patients: 23 PV-dependent AF and 23 with additional extra-PV sources). Results: The classifier yielded 82.6% specificity and 73.9% sensitivity for detecting PV drivers on the clinical data. Consistency analysis on the 46 patients resulted in 93.5% results match. Applying PVI on the simulated AF cases terminated AF in 100% of the cases in the PV class. Conclusion: Machine learning–based classification of 12-lead-ECG allows discrimination between patients with PV drivers vs those with extra-PV drivers of AF. The novel algorithm may aid to identify patients with high acute success rates to PVI.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

QT variability unrelated to RR variability during stress testing for identification of coronary artery disease

  • González del Castillo, Marta
  • Hernando, David
  • Orini, Michele
  • Laguna, Pablo
  • Viik, Jari
  • Bailón, Raquel
  • Pueyo, Esther
Stress test electrocardiogram (ECG) analysis is widely used for coronary artery disease (CAD) diagnosis despite its limited accuracy. Alterations in autonomic modulation of cardiac electrical activity have been reported in CAD patients during acute ischemia. We hypothesized that those alterations could be reflected in changes in ventricular repolarization dynamics during stress testing that could be measured through QT interval variability (QTV). However, QTV is largely dependent on RR interval variability (RRV), which might hinder intrinsic ventricular repolarization dynamics. In this study, we investigated whether different markers accounting for low-frequency (LF) oscillations of QTV unrelated to RRV during stress testing could be used to separate patients with and without CAD. Power spectral density of QTV unrelated to RRV was obtained based on time-frequency coherence estimation. Instantaneous LF power of QTV and QTV unrelated to RRV were obtained. LF power of QTV unrelated to RRV normalized by LF power of QTV was also studied. Stress test ECG of 100 patients were analysed. Patients referred to coronary angiography were classified into non-CAD or CAD group. LF oscillations in QTV did not show significant differences between CAD and non-CAD groups. However, LF oscillations in QTV unrelated to RRV were significantly higher in the CAD group as compared with the non-CAD group when measured during the first phases of exercise and last phases of recovery. ROC analysis of these indices revealed area under the curve values ranging from 61 to 73%. Binomial logistic regression analysis revealed LF power of QTV unrelated to RRV, both during the first phase of exercise and last phase of recovery, as independent predictors of CAD. In conclusion, this study highlights the importance of removing the influence of RRV when measuring QTV during stress testing for CAD identification and supports the added value of LF oscillations of QTV unrelated to RRV to diagnose CAD from the first minutes of exercise. This article is part of the theme issue 'Advanced computation in cardiovascular physiology: new challenges and opportunities'.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG-based monitoring of blood potassium concentration: Periodic versus principal component as lead transformation for biomarker robustness

  • Palmieri, Flavio
  • Gomis, Pedro
  • Ruiz, José Esteban
  • Ferreira, Dina
  • Martín-Yebra, Alba
  • Pueyo, Esther
  • Martínez, Juan Pablo
  • Ramírez, Julia
  • Laguna, Pablo
Objective: The aim of this study is to compare the performance of two electrocardiogram (ECG) lead-space reduction (LSR) techniques in generating a transformed ECG lead from which T-wave morphology markers can be reliably derived to non-invasively monitor blood potassium concentration ([K+]) in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD). These LSR techniques are: (1) principal component analysis (PCA), learned on the T wave, and (2) periodic component analysis (πCA), either learned on the whole QRST complex (πCB) or on the T wave (πCT). We hypothesized πCA is less sensitive to non-periodic disturbances, like noise and body position changes (BPC), than PCA, thus leading to more reliable T wave morphology markers. Methods: We compared the ability of T wave morphology markers obtained from PCA, πCB and πCT in tracking [K+] in an ESRD-HD dataset, including 29 patients, during and after HD (evaluated by correlation and residual fitting error analysis). We also studied their robustness to BPC using an annotated database, including 20 healthy individuals, as well as to different levels of noise using a simulation set-up (assessed by means of Mann–Whitney U test and relative error, respectively). Results: The performance of both πCB and πCT-based markers in following [K+]-variations during HD was comparable, and superior to that from PCA-based markers. Moreover, πCT-based markers showed superior robustness against BPC and noise. Conclusion: Both πCB and πCT outperform PCA in terms of monitoring [K+] in ESRD-HD patients, as well as of robustness against BPC and low SNR, with πCT showing the highest stability for continuous post-HD monitoring. Significance: The usage of πCA (i) increases the accuracy in monitoring dynamic [K+] variations in ESRD-HD patients and (ii) reduces the sensitivity to BPC and noise in deriving T wave morphology markers. © 2021 The Author(s)
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Reseña (Review)

Emerging evidence for a mechanistic link between low-frequency oscillation of ventricular repolarization measured from the electrocardiogram T-wave vector and arrhythmia

  • Taggart, P.
  • Pueyo, E.
  • Van Duijvenboden, S.
  • Porter, B.
  • Bishop, M.
  • Sampedro-Puente, D. A.
  • Orini, M.
  • Hanson, B.
  • Rinaldi, C. A.
  • Gill, J. S.
  • Lambiase, P.
Strong recent clinical evidence links the presence of prominent oscillations of ventricular repolarization in the low-frequency range (0.04-0.15 Hz) to the incidence of ventricular arrhythmia and sudden death in post-MI patients and patients with ischaemic and non-ischaemic cardiomyopathy. It has been proposed that these oscillations reflect oscillations of ventricular action potential duration at the sympathetic nerve frequency. Here we review emerging evidence to support that contention and provide insight into possible underlying mechanisms for this association.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A real-time ppg peak detection method for accurate determination of heart rate during sinus rhythm and cardiac arrhythmia

  • Han, Dong
  • Bashar, Syed Khairul
  • Lázaro, Jesús
  • Mohagheghian, Fahimeh
  • Peitzsch, Andrew
  • Nishita, Nishat
  • Ding, Eric
  • Dickson, Emily L.
  • DiMezza, Danielle
  • Scott, Jessica
  • Whitcomb, Cody
  • Fitzgibbons, Timothy P.
  • McManus, David D.
  • Chon, Ki H.
Objective: We have developed a peak detection algorithm for accurate determination of heart rate, using photoplethysmographic (PPG) signals from a smartwatch, even in the presence of various cardiac rhythms, including normal sinus rhythm (NSR), premature atrial contraction (PAC), premature ventricle contraction (PVC), and atrial fibrillation (AF). Given the clinical need for accurate heart rate estimation in patients with AF, we developed a novel approach that reduces heart rate estimation errors when compared to peak detection algorithms designed for NSR. Methods: Our peak detection method is composed of a sequential series of algorithms that are combined to discriminate the various arrhythmias described above. Moreover, a novel Poincaré plot scheme is used to discriminate between basal heart rate AF and rapid ventricular response (RVR) AF, and to differentiate PAC/PVC from NSR and AF. Training of the algorithm was performed only with Samsung Simband smartwatch data, whereas independent testing data which had more samples than did the training data were obtained from Samsung’s Gear S3 and Galaxy Watch 3. Results: The new PPG peak detection algorithm provides significantly lower average heart rate and interbeat interval beat-to-beat estimation errors—30% and 66% lower—and mean heart rate and mean interbeat interval estimation errors—60% and 77% lower—when compared to the best of the seven other traditional peak detection algorithms that are known to be accurate for NSR. Our new PPG peak detection algorithm was the overall best performers for other arrhythmias. Conclusion: The proposed method for PPG peak detection automatically detects and discriminates between various arrhythmias among different waveforms of PPG data, delivers significantly lower heart rate estimation errors for participants with AF, and reduces the number of false negative peaks. Significance: By enabling accurate determination of heart rate despite the presence of AF with rapid ventricular response or PAC/PVCs, we enable clinicians to make more accurate recommendations for heart rate control from PPG data.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Monitoring of serum potassium and calcium levels in end-stage renal disease patients by ecg depolarization morphology analysis

  • Bukhari, Syed Hassaan Ahmed
  • Sánchez, Carlos
  • Ruiz, José Esteban
  • Potse, Mark
  • Laguna, Pablo
  • Pueyo, Esther
Objective: Non-invasive estimation of serum potassium, [K+], and calcium, [Ca2+], can help to prevent life-threatening ventricular arrhythmias in patients with advanced renal disease, but current methods for estimation of electrolyte levels have limitations. We aimed to develop new markers based on the morphology of the QRS complex of the electrocardiogram (ECG). Methods: ECG recordings from 29 patients undergoing hemodialysis (HD) were processed. Mean warped QRS complexes were computed in two-minute windows at the start of an HD session, at the end of each HD hour and 48 h after it. We quantified QRS width, amplitude and the proposed QRS morphology-based markers that were computed by warping techniques. Reference [K+] and [Ca2+] were determined from blood samples acquired at the time points where the markers were estimated. Linear regression models were used to estimate electrolyte levels from the QRS markers individually and in combination with T wave morphology markers. Leave-one-out cross-validation was used to assess the performance of the estimators. Results: All markers, except for QRS width, strongly correlated with [K+] (median Pearson correlation coefficients, r, ranging from 0.81 to 0.87) and with [Ca2+] (r ranging from 0.61 to 0.76). QRS morphology markers showed very low sensitivity to heart rate (HR). Actual and estimated serum electrolyte levels differed, on average, by less than 0.035 mM (relative error of 0.018) for [K+] and 0.010 mM (relative error of 0.004) for [Ca2+] when patient-specific multivariable estimators combining QRS and T wave markers were used. Conclusion: QRS morphological markers allow non-invasive estimation of [K+] and [Ca2+] with low sensitivity to HR. The estimation performance is improved when multivariable models, including T wave markers, are considered. Significance: Markers based on the QRS complex of the ECG could contribute to non-invasive monitoring of serum electrolyte levels and arrhythmia risk prediction in patients with renal disease
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Strain Echocardiography to Predict Postoperative Atrial Fibrillation

  • Sanchez, Francisco Javier
  • Pueyo, Esther
  • Diez, Emiliano Raúl
Postoperative atrial fibrillation (POAF) complicates 15% to 40% of cardiovascular surgeries. Its incidence progressively increases with aging, reaching 50% in octogenarians. This arrhythmia is usually transient but it increases the risk of embolic stroke, prolonged hospital stay, and cardiovascular mortality. Though many pathophysiological mechanisms are known, POAF prediction is still a hot topic of discussion. Doppler echocardiogram and, lately, strain echocardiography have shown significant capacity to predict POAF. Alterations in oxidative stress, calcium handling, mitochondrial dysfunction, inflammation, fibrosis, and tissue aging are among the mechanisms that predispose patients to the perfect "atrial storm". Manifestations of these mechanisms have been related to enlarged atria and impaired function, which can be detected prior to surgery. Specific alterations in the atrial reservoir and pump function, as well as atrial dyssynchrony determined by echocardiographic atrial strain, can predict POAF and help to shed light on which patients could benefit from preventive therapy.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Editorial: Atrial Fibrillation: Technology for Diagnosis, Monitoring, and Treatment

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Analysis of age-related left ventricular collagen remodeling in living donors: Implications in arrhythmogenesis

  • García-Mendívil, Laura
  • Pérez-Zabalza, María
  • Mountris, Konstantinos
  • Duwé, Sam
  • Smisdom, Nick
  • Pérez, Marta
  • Luján, Lluis
  • Wolfs, Esther
  • Driesen, Ronald B.
  • Vallejo-Gil, José María
  • Fresneda-Roldán, Pedro Carlos
  • Fañanás-Mastral, Javier
  • Vázquez-Sancho, Manuel
  • Matamala-Adell, Marta
  • Sorribas-Berjón, Juan Fernando
  • Bellido-Morales, Javier André
  • Mancebón-Sierra, Francisco Javier
  • Vaca-Núñez, Alexander Sebastián
  • Ballester-Cuenca, Carlos
  • Oliván-Viguera, Aida
  • Diez, Emiliano
  • Ordovás, Laura
  • Pueyo, Esther
Age-related fibrosis in the left ventricle (LV) has been mainly studied in animals by assessing collagen content. Using second-harmonic generation microscopy and image processing, we evaluated amount, aggregation and spatial distribution of LV collagen in young to old pigs, and middle-age and elder living donors. All collagen features increased when comparing adult and old pigs with young ones, but not when comparing adult with old pigs or middle-age with elder individuals. Remarkably, all collagen parameters strongly correlated with lipofuscin, a biological age marker, in humans. By building patient-specific models of human ventricular tissue electrophysiology, we confirmed that amount and organization of fibrosis modulated arrhythmia vulnerability, and that distribution should be accounted for arrhythmia risk assessment. In conclusion, we characterize the age-associated changes in LV collagen and its potential implications for ventricular arrhythmia development. Consistency between pig and human results substantiate the pig as a relevant model of age-related LV collagen dynamics. © 2022 The Author(s)
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modelización matemática y simulación computacional de la variabilidad espacio-temporal en la actividad eléctrica cardíaca

  • Pueyo Paules, Esther
The electrical activity of the heart is the result of complex biophysical and biochemical processes occurring at different scales ranging from submicroscopic to macroscopic. The variability arising from these processes has important effects on cardiac function under both physiological and pathological conditions. In this review, mathematical modeling and simulation of cardiac electrical variability at the level of the cell, tissue and whole organ will be reviewed. A set of studies will be presented, which investigate the role that the stochastic gating of ion channels of cardiac cell membranes plays in the generation of electrical voltage variations along time. Also, methodologies for the development, calibration and evaluation of populations of mathematical models able to represent variations in cardiac electrophysiology across space, i.e. among cells, tissues or individuals, will be described. In particular, methods based on state-space representations, dimension reduction techniques and nonlinear adaptive filtering will be presented and their capacity to replicate experimentally measured spatio-temporal variability will be illustrated. The importance of these methodologies will be shown as a means to ascertain the mechanisms underlying variability, to establish the link between variability and cardiac arrhythmias (irregularities in heart beating) and to propose clinical markers for diagnosis, monitoring and treatment of cardiac diseases.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

QT interval Adaptation to Heart Rate Changes in Atrial Fibrillation as a Predictor of Sudden Cardiac Death

  • Martin-Yebra, A.
  • Sornmo, L.
  • Laguna, P.
Objective: The clinical significance of QT interval adaptation to heart rate changes has been poorly investigated in atrial fibrillation (AF), since QT delineation in the presence of f-waves is challenging. Therefore, the objective of the present study is to investigate new techniques for QT adaptation estimation in permanent AF. Methods: A multilead strategy based on generalized periodic component analysis is proposed for QT delineation, involving a spatial, linear transformation which emphasizes Twave periodicity and attenuates f-waves. QT adaptation is modeled by a linear, time-invariant filter, whose impulse response describes the dependence between the current QT interval and the preceding RR intervals, followed by a memoryless, possibly nonlinear, function. The QT adaptation time lag is determined from the estimated impulse response. Results: Using simulated ECGs in permanent AF, the transformed lead was found to offer more accurate QT delineation and time lag estimation than did the original ECG leads for a wide range of f-wave amplitudes (the time lag estimation error was found to be -0.2+/-0.6 s for SNR = 12 dB). In a population with chronic heart failure and permanent AF, the time lag estimated from the transformed lead was found to have the strongest, statistically significant association with sudden cardiac death (SCD) (hazard ratio = 3.49), whereas none of the original, orthogonal leads had any such association. Conclusions: Periodic component analysis provides more accurate QT delineation and improves time lag estimation in AF. A prolonged adaptation time of the QT interval to heart rate changes is associated with a high risk for SCD. Significance: This study demonstrates that SCD risk markers, originally developed for sinus rhythm, can also be used in AF, provided that Twave periodicity is emphasized. The time lag is a potentially useful marker for identifying patients at high risk for SCD, guiding clinicians in adopting effective therapeutic decisions. IEEE
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Dynamical mechanism for generation of arrhythmogenic early afterdepolarizations in cardiac myocytes: insights from in silico electrophysiological models

  • Barrio, R.
  • Martínez, M. A.
  • Serrano, S.
  • Pueyo, E.
We analyze the dynamical mechanisms underlying the formation of arrhythmogenic early afterdepolarizations (EADs) in two mathematical models of cardiac cellular electrophysiology: the Sato et al. biophysically detailed model of a rabbit ventricular myocyte of dimension 27 and a reduced version of the Luo-Rudy mammalian myocyte model of dimension 3. Based on a comparison of the two models, with detailed bifurcation analysis using spike-counting techniques and continuation methods in the simple model and numerical explorations in the complex model, we locate the point where the first EAD originates in an unstable branch of periodic orbits. These results serve as a basis to propose a conjectured scheme involving a hysteresis mechanism with the creation of alternans and EADs in the unstable branch. This theoretical scheme fits well with electrophysiological experimental data on EAD generation and hysteresis phenomena. Our findings open the door to the development of novel methods for pro-arrhythmia risk prediction related to EAD generation without actual induction of EADs.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A dual adaptive explicit time integration algorithm for efficiently solving the cardiac monodomain equation

  • Mountris K.A.
  • Pueyo E.
The monodomain model is widely used in in-silico cardiology to describe excitation propagation in the myocardium. Frequently, operator splitting is used to decouple the stiff reaction term and the diffusion term in the monodomain model so that they can be solved separately. Commonly, the diffusion term is solved implicitly with a large time step while the reaction term is solved by using an explicit method with adaptive time stepping. In this work, we propose a fully explicit method for the solution of the decoupled monodomain model. In contrast to semi-implicit methods, fully explicit methods present lower memory footprint and higher scalability. However, such methods are only conditionally stable. We overcome the conditional stability limitation by proposing a dual adaptive explicit method in which adaptive time integration is applied for the solution of both the reaction and diffusion terms. We perform a set of numerical examples where cardiac propagation is simulated under physiological and pathophysiological conditions. Results show that the proposed method presents preserved accuracy and improved computational efficiency as compared to standard operator splitting-based methods. © 2021 John Wiley & Sons Ltd.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Fabrication of human myocardium using multidimensional modelling of engineered tissues

  • Montero-Calle, Pilar
  • Flandes-Iparraguirre, María
  • Mountris, Konstantinos
  • S de la Nava, Ana
  • Laita, Nicolás
  • Rosales, Ricardo M
  • Iglesias-García, Olalla
  • de-Juan-Pardo, Elena M
  • Atienza, Felipe
  • Fernández-Santos, María Eugenia
  • Peña, Estefanía
  • Doblaré, Manuel
  • Gavira, Juan J
  • Fernández-Avilés, Francisco
  • Prósper, Felipe
  • Pueyo, Esther
  • Mazo, Manuel M
Biofabrication of human tissues has seen a meteoric growth triggered by recent technical advancements such as human induced pluripotent stem cells (hiPSCs) and additive manufacturing. However, generation of cardiac tissue is still hampered by lack of adequate mechanical properties and crucially by the often unpredictable post-fabrication evolution of biological components. In this study we employ melt electrowriting (MEW) and hiPSC-derived cardiac cells to generate fibre-reinforced human cardiac minitissues. These are thoroughly characterized in order to build computational models and simulations able to predict their post-fabrication evolution. Our results show that MEW-based human minitissues display advanced maturation 28 post-generation, with a significant increase in the expression of cardiac genes such as MYL2, GJA5, SCN5A and the MYH7/MYH6 and MYL2/MYL7 ratios. Human iPSC-cardiomyocytes are significantly more aligned within the MEW-based 3D tissues, as compared to conventional 2D controls, and also display greater expression of C ×43. These are also correlated with a more mature functionality in the form of faster conduction velocity. We used these data to develop simulations capable of accurately reproducing the experimental performance. In-depth gauging of the structural disposition (cellular alignment) and intercellular connectivity (C ×43) allowed us to develop an improved computational model able to predict the relationship between cardiac cell alignment and functional performance. This study lays down the path for advancing in the development of in silico tools to predict cardiac biofabricated tissue evolution after generation, and maps the route towards more accurate and biomimetic tissue manufacture.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cardiac cells stimulated with an axial current-like waveform reproduce electrophysiological properties of tissue fibers

  • Monasterio, Violeta
  • Pueyo, Esther
  • Rodríguez-Matas, José Félix
  • Carro, Jesús
Background and objective: In silico electrophysiological models are generally validated by comparing simulated results with experimental data. When dealing with single-cell and tissue scales simultaneously, as occurs frequently during model development and calibration, the effects of inter-cellular coupling should be considered to ensure the trustworthiness of model predictions. The hypothesis of this paper is that the cell-tissue mismatch can be reduced by incorporating the effects of conduction into the single-cell stimulation current. Methods: Five different stimulation waveforms were applied to the human ventricular O'Hara-Rudy cell model. The waveforms included the commonly used monophasic and biphasic (symmetric and asymmetric) pulses, a triangular waveform and a newly proposed asymmetric waveform (stimulation A) that resembles the transmembrane current associated with AP conduction in tissue. A comparison between single-cell and fiber simulated results was established by computing the relative difference between the values of AP-derived properties at different scales, and by evaluating the differences in the contributions of ionic conductances to each evaluated property. As a proof of the benefit, we investigated multi-scale differences in the simulation of the effects induced by dofetilide, a selective IKr blocker with high torsadogenic risk, on ventricular repolarization at different pacing rates. Results: Out of the five tested stimulation waveforms, stimulation A produced the closest correspondence between cell and tissue simulations in terms of AP properties at steady-state and under dynamic pacing and of ionic contributors to those AP properties. Also, stimulation A reproduced the effects of dofetilide better than the other alternative waveforms, mirroring the ’beat-skipping’ behavior observed at fast pacing rates in experiments with human tissue. Conclusions: The proposed stimulation current waveform accounts for inter-cellular coupling effects by mimicking cell excitation during AP conduction. The proposed waveform improves the correspondence between simulation scales, which could improve the trustworthiness of single-cell simulations without adding computational cost. © 2022
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effects of missing data on heart rate variability metrics

  • Cajal, Diego
  • Hernando, David
  • Lázaro, Jesús
  • Laguna, Pablo
  • Gil, Eduardo
  • Bailón, Raquel
Heart rate variability (HRV) has been studied for decades in clinical environments. Currently, the exponential growth of wearable devices in health monitoring is leading to new challenges that need to be solved. These devices have relatively poor signal quality and are affected by numerous motion artifacts, with data loss being the main stumbling block for their use in HRV analysis. In the present paper, it is shown how data loss affects HRV metrics in the time domain and frequency domain and Poincaré plots. A gap-filling method is proposed and compared to other existing approaches to alleviate these effects, both with simulated (16 subjects) and real (20 subjects) missing data. Two different data loss scenarios have been simulated: (i) scattered missing beats, related to a low signal to noise ratio; and (ii) bursts of missing beats, with the most common due to motion artifacts. In addition, a real database of photoplethysmography-derived pulse detection series provided by Apple Watch during a protocol including relax and stress stages is analyzed. The best correction method and maximum acceptable missing beats are given. Results suggest that correction without gap filling is the best option for the standard deviation of the normal-to-normal intervals (SDNN), root mean square of successive differences (RMSSD) and Poincaré plot metrics in datasets with bursts of missing beats predominance (p<0.05), whereas they benefit from gap-filling approaches in the case of scattered missing beats (p<0.05). Gap-filling approaches are also the best for frequency-domain metrics (p<0.05). The findings of this work are useful for the design of robust HRV applications depending on missing data tolerance and the desired HRV metrics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Obstructive sleep apnoea-related respiratory events and desaturation severity are associated with the cardiac response

  • Hietakoste, S.
  • Karhu, T.
  • Sillanmäki, S.
  • Bailón, R.
  • Penzel, T.
  • Töyräs, J.
  • Leppänen, T.
  • Myllymaa, S.
  • Kainulainen, S.
Obstructive sleep apnoea (OSA) causes, among other things, intermittent blood oxygen desaturations, increasing the sympathetic tone. Yet the effect of desaturations on heart rate variability (HRV), a simple and noninvasive method for assessing sympathovagal balance, has not been comprehensively studied. We aimed to study whether desaturation severity affects the immediate HRV.MethodsWe retrospectively analysed the electrocardiography signals in 5-min segments (n=39 132) recorded during clinical polysomnographies of 642 patients with suspected OSA. HRV parameters were calculated for each segment. The segments were pooled into severity groups based on the desaturation severity (i.e.the integrated area under the blood oxygen saturation curve) and the respiratory event rate within the segment. Covariate-adjusted regression analyses were performed to investigate possible confounding effects.ResultsWith increasing respiratory event rate, the normalised high-frequency band power (HFNU) decreased from 0.517 to 0.364 (p<0.01), the normalised low-frequency band power (LFNU) increased from 0.483 to 0.636 (p<0.01) and the mean RR interval decreased from 915 to 869 ms (p<0.01). Similarly, with increasing desaturation severity, the HFNUdecreased from 0.499 to 0.364 (p<0.01), the LFNUincreased from 0.501 to 0.636 (p<0.01) and the mean RR interval decreased from 952 to 854 ms (p<0.01). Desaturation severity-related findings were confirmed by considering the confounding factors in the regression analyses.ConclusionThe short-term HRV response differs based on the desaturation severity and the respiratory event rate in patients with suspected OSA. Therefore, a more detailed analysis of HRV and desaturation characteristics could enhance OSA severity estimation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Spectral Analysis of Heart Rate Variability in Time-Varying Conditions and in the Presence of Confounding Factors

  • Sornmo, Leif
  • Bailon, Raquel
  • Laguna, Pablo
The tools for spectrally analyzing heart rate variability (HRV) has in recent years grown considerably, with emphasis on the handling of time-varying conditions and confounding factors. Time–frequency analysis holds since long an important position in HRV analysis, however, this technique cannot alone handle a mean heart rate or a respiratory frequency which vary over time. Overlapping frequency bands represents another critical condition which needs to be dealt with to produce accurate spectral measurements. The present survey offers a comprehensive account of techniques designed to handle such conditions and factors by providing a brief description of the main principles of the different methods. Several methods derive from a mathematical/statistical model, suggesting that the model can be used to simulate data used for performance evaluation. The inclusion of a respiratory signal, whether measured or derived, is another feature of many recent methods, e.g., used to guide the decomposition of the HRV signal so that signals related as well as unrelated to respiration can be analyzed. It is concluded that the development of new approaches to handling time-varying scenarios are warranted, as is benchmarking of performance evaluated in technical as well as in physiological/clinical terms.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Physical activity in centenarians beyond cut-point-based accelerometer metrics

  • Hernández-Vicente, A.
  • Marín Puyalto, J.
  • Pueyo, E.
  • Vicente Rodríguez, G.
  • Garatachea, N.
This study described and compared physical activity (PA) characteristics at the end of the human lifespan using conventional cut-point-based versus cut-point-free accelerometer metrics. Eighteen institutionalized centenarians (101.5 ± 2.1 years, 72.2% female, 89% frail) wore the wrist GENEActiv accelerometer for 7 days. Conventional metrics, such as time spent in light-intensity PA (LiPA) and moderate-to-vigorous intensity PA (MVPA) were calculated according to published cut-points for adults and older adults. The following cut-point-free metrics were evaluated: average acceleration, intensity gradient and Mx metrics. Depending on the cut-point, centenarians accumulated a median of 15–132 min/day of LiPA and 3–15 min/day of MVPA. The average acceleration was 9.2 mg [Q1: 6.7 mg–Q3: 12.6 mg] and the intensity gradient was −3.19 [−3.34–−3.12]. The distribution of Z-values revealed positive skew for MVPA, indicating a potential floor effect, whereas the skew magnitude was attenuated for cut-point-free metrics such as intensity gradient or M5. However, both cut-point-based and cut-point-free metrics were similarly positively associated with functional independence, cognitive and physical capacities. This is the first time that PA has been described in centenarians using cut-point-free metrics. Our results suggest that new analytical approaches could overcome cut-point limitations when studying the oldest-old. Future studies using these new cut-point-free PA metrics are warranted to provide more complete and comparable information across groups and populations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Reliability of pulse photoplethysmography sensors: Coverage using different setups and body locations

  • Armañac-Julián, Pablo
  • Kontaxis, Spyridon
  • Rapalis, Andrius
  • Marozas, Vaidotas
  • Laguna, Pablo
  • Bailón, Raquel
  • Gil, Eduardo
  • Lázaro, Jesús
Pulse photoplethysmography (PPG) is a simple and economical technique for obtaining cardiovascular information. In fact, PPG has become a very popular technology among wearable devices. However, the PPG signal is well-known to be very vulnerable to artifacts, and a good quality signal cannot be expected for most of the time in daily life. The percentage of time that a given measurement can be estimated (e.g., pulse rate) is denoted coverage (C), and it is highly dependent on the subject activity and on the configuration of the sensor, location, and stability of contact. This work aims to quantify the coverage of PPG sensors, using the simultaneously recorded electrocardiogram as a reference, with the PPG recorded at different places in the body and under different stress conditions. While many previous works analyzed the feasibility of PPG as a surrogate for heart rate variability analysis, there exists no previous work studying coverage to derive other cardiovascular indices. We report the coverage not only for estimating pulse rate (PR) but also for estimating pulse arrival time (PAT) and pulse amplitude variability (PAV). Three different datasets are analyzed for this purpose, consisting of a tilt-table test, an acute emotional stress test, and a heat stress test. The datasets include 19, 120, and 51 subjects, respectively, with PPG at the finger and at the forehead for the first two datasets and at the earlobe, in addition, for the latter. C ranges from 70% to 90% for estimating PR. Regarding the estimation of PAT, C ranges from 50% to 90%, and this is very dependent on the PPG sensor location, PPG quality, and the fiducial point (FP) chosen for the delineation of PPG. In fact, the delineation of the FP is critical in time for estimating derived series such as PAT due to the small dynamic range of these series. For the estimation of PAV, the C rates are between 70% and 90%. In general, lower C rates have been obtained for the PPG at the forehead. No difference in C has been observed between using PPG at the finger or at the earlobe. Then, the benefits of using either will depend on the application. However, different C rates are obtained using the same PPG signal, depending on the FP chosen for delineation. Lower C is reported when using the apex point of the PPG instead of the maximum flow velocity or the basal point, with a difference from 1% to even 10%. For further studies, each setup should first be analyzed and validated, taking the results and guidelines presented in this work into account, to study the feasibility of its recording devices with respect to each specific application.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Atrial fibrosis identification with unipolar electrogram eigenvalue distribution analysis in multi-electrode arrays

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher, Sara
  • Martinez-Mateu, Laura
  • Saiz, Javier
  • Invers-Rubio, Eric
  • Guillem, Maria S.
  • Martínez, Juan Pablo
  • Laguna, Pablo
Atrial fbrosis plays a key role in the initiation and progression of atrial fbrillation (AF). Atrial fbrosis is typically identifed by a peak-to-peak amplitude of bipolar electrograms (b-EGMs) lower than 0.5 mV, which may be considered as ablation targets. Nevertheless, this approach disregards signal spatiotemporal information and b-EGM sensitivity to catheter orientation. To overcome these limitations, we propose the dominant-to-remaining eigenvalue dominance ratio (EIGDR) of unipolar electrograms (u-EGMs) within neighbor electrode cliques as a waveform dispersion measure, hypothesizing that it is correlated with the presence of fbrosis. A simulated 2D tissue with a fbrosis patch was used for validation. We computed EIGDR maps from both original and time-aligned u-EGMs, denoted as R and RA, respectively, also mapping the gain in eigenvalue concentration obtained by the alignment, ΔRA. The performance of each map in detecting fbrosis was evaluated in scenarios including noise and variable electrode-tissue distance. Best results were achieved by RA, reaching 94% detection accuracy, versus the 86% of b-EGMs voltage maps. The proposed strategy was also tested in real u-EGMs from fbrotic and non-fbrotic areas over 3D electroanatomical maps, supporting the ability of the EIGDRs as fbrosis markers, encouraging further studies to confrm their translation to clinical settings.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Ventilatory Thresholds Estimation Based on ECG-derived Respiratory Rate

  • Garcia, Diego
  • Kontaxis, Spyridon
  • Hernandez-Vicente, Adrian
  • Hernando, David
  • Milagro, Javier
  • Pueyo, Esther
  • Garatachea, Nuria
  • Bailon, Raquel
  • Lazaro, Jesus
The purpose of this work is to study the feasibility of estimating the first and second ventilatory thresholds (VT1 and VT2, respectively) by using electrocardiogram (ECG)-derived respiratory rate during exercise testing. The ECGs of 25 healthy volunteers during cycle ergometer exercise test with increasing workload were analyzed. Time-varying respiratory rate was estimated from an ECG-derived respiration signal obtained from QRS slopes' range method. VT1 and VT2 were estimated as the points of maximum change in respiratory rate slope using polynomial spline smoothing. Reference VT1 and VT2 were determined from the ventilatory equivalents of O2 and CO2. Estimation errors (in watts) of -13.96 (54.84) W for VT1 and -8.06 (39.63) Wfor VT2 (median (interquartile range)) were obtained, suggesting that ventilatory thresholds can be estimated from solely the ECG signal.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A meshless fragile points method for rule-based definition of myocardial fiber orientation

  • Mountris, Konstantinos A.
  • Pueyo, Esther
Background and objective: Rule-based methods are commonly used to estimate the arrangement of myocardial fibers by solving the Laplace problem with appropriate Dirichlet boundary conditions. Existing algorithms are using the Finite Element Method (FEM) to solve the Laplace–Dirichlet problem. However, meshless methods are under development for cardiac electrophysiology simulation. The objective of this work is to propose a meshless rule based method for the determination of myocardial fiber arrangement without requiring a mesh discretization as it is required by FEM. Methods: The proposed method employs the Fragile Points Method (FPM) for the solution of the Laplace–Dirichlet problem. FPM uses simple discontinuous trial functions and single-point exact integration for linear trial functions that set it as a promising alternative to the Finite Element Method. We derive the FPM formulation of the Laplace–Dirichlet and we estimate ventricular and atrial fiber arrangements according to rules based on histology findings for four different geometries. The obtained fiber arrangements from FPM are compared with the ones obtained from FEM by calculating the angle between the fiber vector fields of the two methods for three different directions (i.e., longitudinal, sheet, transverse). Results:The fiber arrangements that were generated with FPM were in close agreement with the generated arrangements from FEM for all three directions. The mean angle difference between the FPM and FEM vector fields were lower than for the ventricular fiber arrangements and lower than for the atrial fiber arrangements. Discussion:The proposed meshless rule-based method was proven to generate myocardial fiber arrangements with very close agreement with FEM while alleviates the requirement for a mesh of the latter. This is of great value for cardiac electrophysiology solvers that are based on meshless methods since they require a well defined myocardial fiber arrangement to simulate accurately the propagation of electrical signals in the heart. Combining a meshless solution for both the determination of the fibers and the electrical signal propagation can allow for solution that do not require the definition of a mesh. To our knowledge, this work is the first one to propose a meshless rule-based method for myocardial fiber arrangement determination.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic Nervous System characterization in hyperbaric environments considering respiratory component and non-linear analysis of Heart Rate Variability

  • Hernando, A.
  • Posada Quintero, H.
  • Peláez Coca, M. D.
  • Gil, E.
  • Chon, K. H.
Objectives: an evaluation of Principal Dynamic Mode (PDM) and Orthogonal Subspace Projection (OSP) methods to characterize the Autonomic Nervous System (ANS) response in three different hyperbaric environments was performed. Methods: ECG signals were recorded in two different stages (baseline and immersion) in three different hyperbaric environments: (a) inside a hyperbaric chamber, (b) in a controlled sea immersion, (c) in a real reservoir immersion. Time-domain parameters were extracted from the RR series of the ECG. From the Heart Rate Variability signal (HRV), classic Power Spectral Density (PSD), PDM (a non-linear analysis of HRV which is able to separate sympathetic and parasympathetic activities) and OSP (an analysis of HRV which is able to extract the respiratory component) methods were used to assess the ANS response. Results: PDM and OSP parameters follows the same trend when compared to the PSD ones for the hyperbaric chamber dataset. Comparing the three hyperbaric scenarios, significant differences were found: i) heart rate decreased and RMSSD increased in the hyperbaric chamber and the controlled dive, but they had the opposite behavior during the uncontrolled dive; ii) power in the OSP respiratory component was lower than power in the OSP residual component in cases a and c; iii) PDM and OSP methods showed a significant increase in sympathetic activity during both dives, but parasympathetic activity increased only during the uncontrolled dive. Conclusions: PDM and OSP methods could be used as an alternative measurement of ANS response instead of the PSD method. OSP results indicate that most of the variation in the heart rate variability cannot be described by changes in the respiration, so changes in ANS response can be assigned to other factors. Time-domain parameters reflect vagal activation in the hyperbaric chamber and in the controlled dive because of the effect of pressure. In the uncontrolled dive, sympathetic activity seems to be dominant, due to the effects of other factors such as physical activity, the challenging environment, and the influence of breathing through the scuba mask during immersion. In sum, a careful description of the changes in all the possible factors that could affect the ANS response between baseline and immersion stages in hyperbaric environments is needed for better interpretation of the results.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Blunted autonomic reactivity to mental stress in depression quantified by nonlinear cardiorespiratory coupling indices

  • Kontaxis, Spyridon
  • Laguna, Pablo
  • García Pages, Esther
  • Posadas-de Miguel, Mar
  • Siddi, Sara
  • Luisa Bernal, Maria
  • Maria Haro, Josep
  • Aguiló, Jordi
  • de la Camara, Concepción
  • Bailón, Raquel
  • Gil, Eduardo
In this study, differences in autonomic reactivity to mental stress between Major Depressive Disorder (MDD) patients and healthy control (HC) subjects are assessed by nonlinear cardiorespiratory coupling indices derived from the Real Wavelet Biphase. The degree and strength of Quadratic Phase Coupling (QPC) between interacting oscillations of Heart Rate Variability (HRV) and respiration are quantified before, during and after the execution of acognitive task. Results show that the QPC strength and QPC degree between the respiration and the respiratory sinus arrhythmia component of HRV were lower in HC compared to MDD during stress, suggesting that the parasympathetic branch was less inhibited in MDD patients. During recovery, only in HC group, this degree of QPC increased, while the respiratory rate was reduced, compared to the basal stage. The degree of QPC between the respiration and components of HRV in the low frequency band ([0.04, 0.15] Hz) increased in HC during stress, compared to the basal stage, while remained unchanged in MDD patients. These results imply that depression is associated with blunted autonomic reactivity to mental stress
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Deep-Learning-Based Estimation of the Spatial QRS-T Angle from Reduced-Lead ECGs

  • Santos Rodrigues, Ana
  • Augustauskas, Rytis
  • Lukosevicius, Mantas
  • Laguna, Pablo
  • Marozas, Vaidotas
The spatial QRS-T angle is a promising health indicator for risk stratification of sudden cardiac death (SCD). Thus far, the angle is estimated solely from 12-lead electrocardiogram (ECG) systems uncomfortable for ambulatory monitoring. Methods to estimate QRS-T angles from reduced-lead ECGs registered with consumer healthcare devices would, therefore, facilitate ambulatory monitoring. (1) Objective: Develop a method to estimate spatial QRS-T angles from reduced-lead ECGs. (2) Approach: We designed a deep learning model to locate the QRS and T wave vectors necessary for computing the QRS-T angle. We implemented an original loss function to guide the model in the 3D space to search for each vector''s coordinates. A gradual reduction of ECG leads from the largest publicly available dataset of clinical 12-lead ECG recordings (PTB-XL) is used for training and validation. (3) Results: The spatial QRS-T angle can be estimated from leads {I, II, aVF, V2} with sufficient accuracy (absolute mean and median errors of 11.4 degrees and 7.3 degrees) for detecting abnormal angles without sacrificing patient comfortability. (4) Significance: Our model could enable ambulatory monitoring of spatial QRS-T angles using patch- or textile-based ECG devices. Populations at risk of SCD, like chronic cardiac and kidney disease patients, might benefit from this technology.