Pasar al contenido principal

FABRICACION ADITIVA DE HIDROGELES DINAMICOS SIMPLES Y DOBLES A PARTIR DE POLIMEROS NATURALES Y NANOCOMPUESTOS

PID2023-149734NB-C21

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2023
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Raw data employed in the study: 'Hexadecylamine addition promotes crystallization-driven functionalities in freezing-thawing PVA hydrogels'

  • Alvear-Jiménez, Alexis
  • Fernández, Mercedes
  • Müller, Alejandro J.
  • Hernández, Rebeca
[Description of methods used for collection/generation of data] All measurements were performed under standard conditions, except for those experiments involving temperature ramps., [Methods for processing the data] The data have been organized to improve visualization. Each .dat file in the WAXS dataset corresponds to one degree in the temperature ramp, e.g., 0000 = 10°C, 0001 = 11°C, ..., 0070 = 80°C, This dataset contains raw data from hydrogels obtained through freeze-thawing cycles of aqueous solutions of polyvinyl alcohol (PVA) and its blends with hexadecylamine. The data were collected using a range of experimental techniques including Wide Angle X-ray Scattering (WAXS), Raman spectroscopy, Differential Scanning Calorimetry (DSC), and rheological measurements., This research was financially supported by the projects PID2020-113045GB-C21 and C22 and PID2023-149734NB-C21 and C22 funded by MCIU/ AEI/10.13039/501100011033. FPI contract (PRE2021-100838) and ALBA synchrotron granted proposal AV-2023097792, -WAXS_PVA_ASPREPARED -WAXS_PVA_PARTIALLYDRIED -WAXS_PVAC16_3_ASPREPARED - WAXS_PVAC16_3_PARTIALLYDRIED - ADHESION - DSC - RAMAN_SPECTRA - RHEOLOGY_STRAINFREQUENCY_ANNEALED - RHEOLOGY_STRAINFREQUENCY_ASPREPARED - RHEOLOGY_TEMPERATURE_ANNEALED - RHEOLOGY_TEMPERATURE_ASPREPARED, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Raw data regarding rheological characterization, pore size determination and printability of the materials employed in the study: “Genipin-Crosslinked Pectin Hydrogels: A Dual Strategy for Enhanced 3D Printability and Stability”

  • Mercado-Rico, Jorge
  • Pérez-Pérez, Luis
  • Hernández, Rebeca
[Description of methods used for collection/generation of data] Rheological data. The rheological properties of all the materials were determined using a rotational rheometer (AR-G2, TA Instruments, USA) equipped with a 20 mm cross-hatched stainless steel Peltier plate geometry. Oscillatory frequency sweep tests were conducted on pectin-genipin hydrogels swollen at equilibrium over a frequency range of 0.01–10 Hz, at a temperature of 25 ºC and at a constant strain of 1%, located within the linear viscoelastic region (LVR). An oscillatory amplitude sweep (1 Hz; γ = 0.01%–500%) was performed to determine the critical strain, defined as the point at which a 5% decrease in the storage modulus (G′) is observed. Subsequently, frequency sweep tests (1% strain, 0.01–100 Hz) were carried out to measure the storage modulus (G′) and loss modulus (G″). Finally, hydrogel recovery test varying the strain from 1% to 200% at a constant frequency of 1 Hz, applying 2 cycles at high strain. Printability tests. Scaffolds were fabricated via 3D printing using a Creality Ender 3 Pro filament printer, which was adapted to enable the extrusion of polymeric hydrogels. The uniformity factor (U) was used to evaluate how uniform the filament was compared to a perfectly straight filament. Digimizer software was used to manually measure the outer edge on both sides of the filament. This length was then divided by the length of the reference line to calculate the uniformity factor (equation 2), which indicates whether the filament is uniform (U = 1) or non-uniform (U > 1). U"\=" (length"\ "of"\ "printed"\ "filament"\ ")/(length"\ "of"\ "theorical"\ "straight"\ "filament) (Equation 1) For the determination of the printability index, Pr, a single layer cylindrical scaffold was printed with an internal design configured to form 12 squares with a side length of 3 mm each. The area of each internal square was quantified using Digimizer software, and these values were used to calculate the average printability index (Pr) according to equation 3. Based on this index, three gelation states are identified: insufficient gelation (Pr < 1), adequate gelation (Pr = 1), and excessive gelation (Pr > 1). Pr"\=" π/4 x 1/C "\=" L^2/16A "\ "(Equation"\ " 2) Pore size. Pore size was quantified using ImageJ. Micrographs were calibrated with the scale bar, and image preprocessing (contrast enhancement and threshold adjustment) was applied to delineate pore boundaries. Approximately 45 pores were analyzed per sample, and the equivalent circular diameter was calculated from the pore area. Results were reported as mean ± standard deviation (SD) to describe pore size distribution., [Methods for processing the data] The files contain raw data obtained through rheological measurements, pore size determination and printability tests are organized in EXCEL files to improve visualization., This dataset contains raw data from obtained through oscillatory rheological measurements, pore size determination and printability tests organized in EXCEL files and employed in the study “Genipin-Crosslinked Pectin Hydrogels: A Dual Strategy for Enhanced 3D Printability and Stability”, This research has been funded by the projects PID2020-113045GB-C22 and PID2023-149734NB-C21 by MCIN/AEI/10.13039/501100011033, the “Industrial Doctorate” call (DIN2019-010868), and the DIGIMATER-CM project (TEC-2024/TEC-102) funded by the Community of Madrid, Peer reviewed