Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Structure, morphology, adhesion and in vitro biological evaluation of antibacterial multi-layer HA-Ag/SiO2/TiN/Ti coatings obtained by RF magnetron sputtering for biomedical applications

  • Lenis, J. A.
  • Pacha-Olivenza, M. A.
  • González-Martín, M. L.
  • Bolívar, F. J.
  • Rico Tortosa, Patricia María
  • Gómez Ribelles, José Luís|||0000-0001-9099-0885
[EN] Biocompatible and antibacterial multi-layer coatings of hydroxyapatite (HA)-Ag/SiO2/TiN/Ti were obtained on the Ti-6Al-4V alloy, by means of the magnetron sputtering technique. During characterization of the coatings, the chemical composition was evaluated by energy dispersive X-ray spectroscopy and the phase analysis was carried out by X-ray diffraction. The morphology of the coatings was observed by field emission scanning electron microscopy, while transmission electron microscopy was used to appreciate their structure. The adhesion of the coatings to the substrate was evaluated by micro scratch test. The in vitro biological response was evaluated in terms of cytotoxicity, adhesion and differentiation of mouse mesenchymal stem cells, as well as adhesion and bacterial viability of Staphylococcus aureus strain. Through the compositional study carried out, the deposition of the HA phase was verified, with a Ca/P ratio close to 1.67 and the characteristic diffraction peaks of this compound. The structural study of the coatings evidenced the obtention of multi-layer architectures. The use of an intermediate SiO2/TiN/Ti trilayer was found to improve adhesion between HA-Ag and the substrate by 84%. Finally, the in vitro biological tests carried out indicated a potentially non-toxic character in the coatings. Additionally, an antibacterial effect was registered at low concentrations of Ag (< 0.25 mg/L)., We thank the University of Antioquia, the Centro de Investigacion, Innovacion y Desarrollo de materiales (CIDEMAT) group, the Departamento Administrativo de Ciencia, Tecnologia e Innovacion (COLCIENCIAS) for financing the Project 15-1696, the scholarship program of Enlazamundos, the Agencia de Educacion Superior de Medellin (Sapiencia), JLGR acknowledges financial support from the Spanish Ministry of Economy and Competitiveness (MINECO) through the project MAT2016-76039-C4-1-R and MAT 2015-63974-C4-3-R (AEI/FEDER, UE) (including the FEDER financial support). PR acknowledges support from the Spanish Ministry of Science, Innovation and Universities (RTI2018-096794), and Fondo Europeo de Desarrollo Regional (FEDER). CIBER-BBN is an initiative funded by the VI National R&D&I Plan 2008-2011, Iniciativa Ingenio 2010, Consolider Program. CIBER Actions are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund, M-ERA.NET PCIN-2016-146 and RTI2018-096862-B-I00, Spanish "Junta de Extremadura" for the projects IB16117, TE-0016-18 and GR18153.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Neutron flux and spectrum in the dresden felsenkeller underground facility studied by moderated he 3 counters

  • Grieger, M.
  • Hensel, T.
  • Agramunt, Jorge
  • Bemmerer, D.
  • Degering, D.
  • Dillmann, I.
  • Fraile, Luis M.
  • Jordan, D.
  • Köster, U.
  • Marta, M.
  • Müller, S.E.
  • Szücs, T.
  • Tain, José Luis
  • Zuber, K.
Ambient neutrons may cause significant background for underground experiments. Therefore, it is necessary to investigate their flux and energy spectrum in order to devise a proper shielding. Here, two sets of altogether ten moderated He3 neutron counters are used for a detailed study of the ambient neutron background in tunnel IV of the Felsenkeller facility, underground below 45 m of rock in Dresden/Germany. One of the moderators is lined with lead and thus sensitive to neutrons of energies higher than 10 MeV. For each He3 counter moderator assembly, the energy-dependent neutron sensitivity was calculated with the FLUKA code. The count rates of the ten detectors were then fitted with the MAXED and GRAVEL packages. As a result, both the neutron energy spectrum from 10-9 to 300 MeV and the flux integrated over the same energy range were determined experimentally. The data show that at a given depth, both the flux and the spectrum vary significantly depending on local conditions. Energy-integrated fluxes of (0.61±0.05), (1.96±0.15), and (4.6±0.4)×10-4 cm-2 s-1, respectively, are measured for three sites within Felsenkeller tunnel IV which have similar muon flux but different shielding wall configurations. The integrated neutron flux data and the obtained spectra for the three sites are matched reasonably well by FLUKA Monte Carlo calculations that are based on the known muon flux and composition of the measurement room walls., Financial support by DFG (BE 4100/4-1), the Helmholtz Association (NAVI VH-VI-417 and ERC-RA-0016), the Spanish Ministerio de Economía y Competitividad (Grants No. FPA2014-52823-C2, No. FPA2017-83946-C2, No. RTI2018-098868-B-I00, and No. SEV-2014-0398/ program Severo Ochoa), and the COST Association (ChETEC CA16117) is gratefully acknowledged