Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 29
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Synthesis and characterization of Pd(II), Pt(II), Cu(I), Ag(I) and Cu(II) complexes with N,O-hybrid pyrazole ligand

  • Guerrero, Miguel|||0000-0001-8350-8261
  • Calvet, Teresa|||0000-0002-4058-7171
  • Font-Bardia, Mercè|||0000-0002-7892-8744
  • Pons Picart, Josefina|||0000-0003-1834-9326
The coordination behavior of N,O-hybrid pyrazole-based metal-organic frameworks are described. 2-(3,5-Pyridyl-1H-pyrazol-1-yl)ethanol (L) and its Pd(II), Pt(II), Cu(I), Ag(I) and Cu(II) complexes with different anions have been synthesized and characterized by elemental analysis, conductivity, mass spectrometry, IR, ¹H, ¹³C{¹H} and ¹⁹⁵Pt{1H} NMR spectroscopies. Complex 1 was also characterized by single crystal X-ray diffraction. For complex 7 has also been possible to perform the UV-Vis and magnetic susceptibility measurements. All complexes are monomers, except the complexes obtained by reaction of the ligand (L) with M(MeCO₂)₂ (M = Pd(II), Pt(II)) or CuBr₂, which are dimers.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Straightforward Immunosensing Platform Based on Graphene Oxide-Decorated Nanopaper, A Highly Sensitive and Fast Biosensing Approach

  • Cheeveewattanagul, Nopchulee
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Hassan, Abdel-Raim H. A.|||0000-0001-7905-6821
  • Bergua Canudo, José Francisco|||0000-0002-5969-193X
  • Surareungchai, Werasak
  • Somasundrum, Mithran
  • Merkoçi, Arben|||0000-0003-2486-8085
Immunoassays are nowadays a crucial tool for diagnostics and drug development. However, they often involve time-consuming procedures and need at least two antibodies in charge of the capture and detection processes, respectively. This study reports a nanocomposite based on graphene oxide-coated nanopaper (GONAP) facilitating an advantageous immunosensing platform using a single antibody and without the need for washing steps. The hydrophilic, porous, and photoluminescence-quenching character of GONAP allows for the adsorption and quenching of photoluminescent quantum dots nanocrystals complexed with antibodies (Ab-QDs), enabling a ready-to-use immunosensing platform. The photoluminescence is recovered upon immunocomplex (antibody-antigen) formation which embraces a series of interactions (hydrogen bonding, electrostatic, hydrophobic, and Van der Waals interactions) that trigger desorption of the antigen-Ab-QD complex from GONAP surface. However, the antigen is then attached onto the GONAP surface by electrostatic interactions leading to a spacer (greater than ≈20 nm) between Ab-QDs and GONAP and thus hindering nonradiative energy transfer. It is demonstrated that this simple-yet highly sensitive-platform represents a virtually universal immunosensing approach by using small-sized and big-sized targets as model analytes, those are, human-IgG protein and Escherichia coli bacteria. In addition, the assay is proved effective in real matrices analysis, including human serum, poultry meat, and river water. GONAP opens the way to conceptually new paper-based devices for immunosensing, which are amenable to point of care applications and automated diagnostics.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Paper strip-embedded graphene quantum dots, a screening device with a smartphone readout

  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Orozco, Jahir|||0000-0001-6249-8092
  • Merkoçi, Arben|||0000-0003-2486-8085
Simple, inexpensive and rapid sensing systems are very demanded for a myriad of uses. Intrinsic properties of emerging paper-based analytical devices have demonstrated considerable potential to fulfill such demand. This work reports an easy-to-use, low cost, and disposable paper-based sensing device for rapid chemical screening with a smartphone readout. The device comprises luminescent graphene quantum dots (GQDs) sensing probes embedded into a nitrocellulose matrix where the resonance energy transfer phenomenon seems to be the sensing mechanism. The GQDs probes were synthesized from citric acid by a pyrolysis procedure, further physisorbed and confined into small wax-traced spots on the nitrocellulose substrate. The GQDs were excited by an UV LED, this, is powered by a smartphone used as both; energy source and imaging capture. The LED was contained within a 3D-printed dark chamber that isolates the paper platform from external light fluctuations leading to highly reproducible data. The cellulose-based device was proven as a promising screening tool for phenols and polyphenols in environmental and food samples, respectively. It opens up new opportunities for simple and fast screening of organic compounds and offers numerous possibilities for versatile applications. It can be especially useful in remote settings where sophisticated instrumentation is not always available.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Bioluminescent nanopaper for rapid screening of toxic substances

  • Liu, Jie
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Orozco, Jahir|||0000-0001-6249-8092
  • Vicent i Huguet, Teresa|||0000-0002-6547-7358
  • Zhong, Guohua
  • Merkoçi, Arben|||0000-0003-2486-8085
Environmental pollution is threatening human health and ecosystems as a result of modern agricultural techniques and industrial progress. A simple nanopaper-based platform coupled with luminescent bacteria Aliivibrio fischeri (A. fischeri) as a bio-indicator is presented here, for rapid and sensitive evaluation of contaminant toxicity. When exposed to toxicants, the luminescence inhibition of A. fischeri-decorated bioluminescent nanopaper (BLN) can be quantified and analyzed to classify the toxicity level of a pollutant. The BLN composite was characterized in terms of morphology and functionality. Given the outstanding biocompatibility of nanocellulose for bacterial proliferation, BLN achieved high sensitivity with a low cost and simplified procedure compared to conventional instruments for laboratory use only. The broad applicability of BLN devices to environmental samples was studied in spiked real matrices (lake and sea water), and their potential for direct and in situ toxicity screening was demonstrated. The BLN architecture not only survives but also maintains its function during freezing and recycling processes, endowing the BLN system with competitive advantages as a deliverable, ready-to-use device for large-scale manufacturing. The novel luminescent bacteria-immobilized, nanocelullose-based device shows outstanding abilities for toxicity bioassays of hazardous compounds, bringing new possibilities for cheap and efficient environmental monitoring of potential contamination.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Graphene-based biosensors, going simple

  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Baptista Pires, Luis Miguel|||0000-0002-2290-6386
  • Zamora Gálvez, Alejandro
  • Merkoçi, Arben|||0000-0003-2486-8085
The main properties of graphene derivatives facilitating optical and electrical biosensing platforms are discussed, along with how the integration of graphene derivatives, plastic, and paper can lead to innovative devices in order to simplify biosensing technology and manufacture easy-to-use, yet powerful electrical or optical biosensors. Some crucial issues to be overcome in order to bring graphene-based biosensors to the market are also underscored.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Biosensors for plant pathogen detection

  • Khater, Mohga
  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Merkoçi, Arben|||0000-0003-2486-8085
Infectious plant diseases are caused by pathogenic microorganisms such as fungi, bacteria, viruses, viroids, phytoplasma and nematodes. Worldwide, plant pathogen infections are among main factors limiting crop productivity and increasing economic losses. Plant pathogen detection is important as first step to manage a plant disease in greenhouses, field conditions and at the country boarders. Current immunological techniques used to detect pathogens in plant include enzyme-linked immunosorbent assays (ELISA) and direct tissue blot immunoassays (DTBIA). DNA-based techniques such as polymerase chain reaction (PCR), real time PCR (RT-PCR) and dot blot hybridization have also been proposed for pathogen identification and detection. However these methodologies are time-consuming and require complex instruments, being not suitable for in-situ analysis. Consequently, there is strong interest for developing new biosensing systems for early detection of plant diseases with high sensitivity and specificity at the point-of-care. In this context, we revise here the recent advancement in the development of advantageous biosensing systems for plant pathogen detection based on both antibody and DNA receptors. The use of different nanomaterials such as nanochannels and metallic nanoparticles for the development of innovative and sensitive biosensing systems for the detection of pathogens (i.e. bacteria and viruses) at the point-of-care is also shown. Plastic and paper-based platforms have been used for this purpose, offering cheap and easy-to-use really integrated sensing systems for rapid on-site detection. Beside devices developed at research and development level a brief revision of commercially available kits is also included in this review.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Production of biofunctionalized MoS2 flakes with rationally modified lysozyme, A biocompatible 2D hybrid material

  • Siepi, Maria Luisa
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Domingo Marimon, Neus|||0000-0002-5229-6638
  • Monti, Daria Maria
  • Notomista, Eugenio
  • Merkoçi, Arben|||0000-0003-2486-8085
Bioapplications of 2D materials embrace demanding features in terms of environmental impact, toxicity and biocompatibility. Here we report on the use of a rationally modified lysozyme to assist the exfoliation of Mos bulk crystals suspended in water through ultrasonic exfoliation. The design of the proposed lysozyme derivative provides this exfoliated 2D-materail with both, hydrophobic groups that interact with the surface of Mos and hydrophilic groups exposed to the aqueous medium, which hinders its re-Aggregation. This approach, clarified also by molecular docking studies, leads to a stable material (ζ-potential, 27 ?} 1 mV) with a yield of up to 430 μg ml-1. The bio-hybrid material was characterized in terms of number of layers and optical properties according to different slots separated by diverse centrifugal forces. Furthermore the obtained material was proved to be biocompatible using human normal keratinocytes and human cancer epithelial cells, whereas the method was demonstrated to be applicable to produce other 2D materials such as graphene. This approach is appealing for the advantageous production of high quality Mos flakes and their application in biomedicine and biosensing. Moreover, this method can be applied to different starting materials, making the denatured lysozyme a promising bio-Tool for surface functionalization of 2D materials.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Rapid on-chip apoptosis assay on human carcinoma cells based on annexin-V/quantum dot probes

  • Montón i Domingo, Helena
  • Medina Sánchez, Mariana|||0000-0001-6149-3732
  • Soler, Joan Antoni
  • Chałupniak, Andrzej
  • Nogués, Carme|||0000-0002-6361-8559
  • Merkoçi, Arben|||0000-0003-2486-8085
Despite all the efforts made over years to study the cancer expression and the metastasis event, there is not a clear understanding of its origins and effective treatment. Therefore, more specialized and rapid techniques are required for studying cell behaviour under different drug-based treatments. Here we present a quantum dot signalling-based cell assay carried out in a segmental microfluidic device that allows studying the effect of anti-cancer drugs in cultured cell lines by monitoring phosphatidylserine translocation that occurs in early apoptosis. The developed platform combines the automatic generation of a drug gradient concentration, allowing exposure of cancer cells to different doses, and the immunolabeling of the apoptotic cells using quantum dot reporters. Thereby a complete cell-based assay for efficient drug screening is performed showing a clear correlation between drug dose and amount of cells undergoing apoptosis.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Mobile phone-based biosensing, An emerging "diagnostic and communication" technology

  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Merkoçi, Arben|||0000-0003-2486-8085
In this review we discuss recent developments on the use of mobile phones and similar devices for biosensing applications in which diagnostics and communications are coupled. Owing to the capabilities of mobile phones (their cameras, connectivity, portability, etc.) and to advances in biosensing, the coupling of these two technologies is enabling portable and user-friendly analytical devices. Any user can now perform quick, robust and easy (bio)assays anywhere and at any time. Among the most widely reported of such devices are paper-based platforms. Herein we provide an overview of a broad range of biosensing possibilities, from optical to electrochemical measurements; explore the various reported designs for adapters; and consider future opportunities for this technology in fields such as health diagnostics, safety & security, and environment monitoring.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Nanochannels for electrical biosensing

  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Merkoçi, Arben|||0000-0003-2486-8085
This review shows the recent trends on the use of both single and array nanochannels for electrical biosensing applications. Some general considerations on the principles of the stochastic sensing, together with an overview about the common routes for nanochannels preparation before focusing on the applications for DNA, protein, virus, toxin and other analytes detection are given. Emerging materials used to obtain nanochannels, such as graphene and its analogues as well as novel systems based on the use of nanoparticles in combination with nanochannels are discussed. Aspects related to the analytical performance of the developed devices are also discussed. Finally prospects for future improvements and applications of this technology are included.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Magnetic bead/gold nanoparticle double-labeled primers for electrochemical detection of isothermal amplified Leishmania DNA

  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Baptista Pires, Luis Miguel|||0000-0002-2290-6386
  • Serrano, Lorena
  • Altet Sanahujes, Laura
  • Francino, Olga|||0000-0002-9022-3835
  • Sánchez Bonastre, Armando|||0000-0001-9160-1124
  • Merkoçi, Arben|||0000-0003-2486-8085
A novel methodology for the isothermal amplification of Leishmania DNA using labeled primers combined with the advantages of magnetic purification/preconcentration and the use of gold nanoparticle (AuNP) tags for the sensitive electrochemical detection of such amplified DNA is developed. Primers labeled with AuNPs and magnetic beads (MBs) are used for the first time for the isothermal amplification reaction, being the amplified product ready for the electrochemical detection. The electrocatalytic activity of the AuNP tags toward the hydrogen evolution reaction allows the rapid quantification of the DNA on screen-printed carbon electrodes. Amplified products from the blood of dogs with Leishmania (positive samples) are discriminated from those of healthy dogs (blank samples). Quantitative studies demonstrate that the optimized method allows us to detect less than one parasite per microliter of blood (8 × 10⁻³ parasites in the isothermal amplification reaction). This pioneering approach is much more sensitive than traditional methods based on real-time polymerase chain reaction (PCR), and is also more rapid, cheap, and user-friendly.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Graphene-based Janus micromotors for the dynamic removal of pollutants

  • Orozco, Jahir|||0000-0001-6249-8092
  • Mercante, Luiza A.
  • Pol, Roberto|||0000-0002-4387-4061
  • Merkoçi, Arben|||0000-0003-2486-8085
Persistent organic pollutants (POPs) are ubiquitous in the environment as a result of modern industrial processes. We present an effective POPs decontamination strategy based on their dynamic adsorption at the surface of reduced graphene oxide (rGO)-coated silica (SiO)-Pt Janus magnetic micromotors for their appropriate final disposition. While the motors rapidly move in a contaminated solution, the adsorption of POPs efficiently takes place in a very short time. Characterization of the micromotors both from the materials and from the motion point of view was performed. Polybrominated diphenyl ethers (PBDEs) and 5-chloro-2-(2,4-dichlorophenoxy) phenol (triclosan) were chosen as model POPs and the removal of the contaminants was efficiently achieved. The rGO-coated micromotors demonstrated superior adsorbent properties with respect to their concomitant GO-coated micromotors, static rGO-coated particles and dynamic silica micromotors counterparts. The extent of decontamination was studied over the number of micromotors, whose magnetic properties were used for their collection from environmental samples. The adsorption properties were maintained for 4 cycles of micromotors reuse. The new rGO-coated SiO functional material-based micromotors showed outstanding capabilities towards the removal of POPs and their further disposition, opening up new possibilities for efficient environmental remediation of these hazardous compounds.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Control of Electron-transfer in Immunonanosensors by Using Polyclonal and Monoclonal Antibodies

  • Mars, Abdelmoneim
  • Parolo, Claudio|||0000-0001-9481-4408
  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Raouafi, Noureddine
  • Merkoçi, Arben|||0000-0003-2486-8085
The design and operation of biosensors is not trivial. For instance, variation in the output signal during monitoring of analytes can not usually be controlled. Hence, if such control were possible, and could be triggered on demand, it would greatly facilitate system design and operation. Herein, we report the design of two types of voltamperometric immunosensors, in which the magnitude of the current output signal (differential pulse voltammetry [DPV]) can be increased or decreased as needed. The designed systems use monoclonal and polyclonal anti-human IgG antibodies, conjugated to monopodal ferrocene-modified gold nanoparticles that are casted onto screen-printed carbon electrodes (Ab/mFcL/AuNPs/SPCEs). Upon addition of human IgG as antigen, the systems exhibit opposite responses according to the Ab: the current decreases when monoclonal Ab is used, whereas it increases when polyclonal Ab is used. We attributed the former response to inhibition of electron-transfer (due to the formation of a protein layer), and the latter response, to a global increase in electron transfer (induced by the aggregation of gold nanoparticles). These effects were confirmed by studying a custom-made lipoic acid-based bipodal ligand, which confirmed that the increase in current is effectively induced by the aggregation of the modified nanoparticles (pAb/mFcL/AuNPs). Both sensors have large dynamic ranges, although the pAb-based one was found to be 3.3-times more sensitive. Tests of selectivity and specificity for ovalbumin, α-lactalbumin and serum bovine albumin showed that the immunosensors are highly selective and specific, even in the presence of up to 1000-fold levels of potentially competitive proteins. The limit of detection for human IgG using the pAb/mFcL/AuNP bioconjugate was estimated to be 0.85 ng/mL. The pAb/mFcL/AuNPs-based biosensor has used to determine amounts of human IgG in real sample.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

In situ monitoring of PTHLH secretion in neuroblastoma cells cultured onto nanoporous membranes

  • De La Escosura-Muñiz, Alfredo|||0000-0002-9600-0253
  • Espinoza Castañeda, Marisol
  • Chamorro García, Alejandro|||0000-0003-0953-5848
  • Rodríguez-Hernández, Carlos J.
  • De Torres, Carmen
  • Merkoçi, Arben|||0000-0003-2486-8085
In this work, we propose for the first time the use of anodic aluminum oxide (AAO) nanoporous membranes for in situ monitoring of parathyroid hormone-like hormone (PTHLH) secretion in cultured human cells. The biosensing system is based on the nanochannels blockage upon immunocomplex formation, which is electrically monitored through the voltammetric oxidation of Prussian blue nanoparticles (PBNPs). Models evaluated include a neuroblastoma cell line (SK-N-AS) and immortalized keratinocytes (HaCaT) as a control of high PTHLH production. The effect of total number of seeded cells and incubation time on the secreted PTHLH levels is assessed, finding that secreted PTHLH levels range from approximately 60 to 400 ng/mL. Moreover, our methodology is also applied to analyse PTHLH production following PTHLH gene knockdown upon transient cell transfection with a specific silencing RNA (siRNA). Given that inhibition of PTHLH secretion reduces cell proliferation, survival and invasiveness in a number of tumors, our system provides a powerful tool for the preclinical evaluation of therapies that regulate PTHLH production. This nanoporous membrane - based sensing technology might be useful to monitor the active secretion of other proteins as well, thus contributing to characterize their regulation and function.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Nanobiosensors in diagnostics

  • Chamorro García, Alejandro|||0000-0003-0953-5848
  • Merkoçi, Arben|||0000-0003-2486-8085
Medical diagnosis has been greatly improved thanks to the development of new techniques capable of performing very sensitive detection and quantifying certain parameters. These parameters can be correlated with the presence of specific molecules and their quantity. Unfortunately, these techniques are demanding, expensive, and often complicated. On the other side, progress in other fields of science and technology has contributed to the rapid growth of nanotechnology. Although being an emerging discipline, nanotechnology has raised huge interest and expectations. Most of the enthusiasm comes from new possibilities and properties of nanomaterials. Biosensors (simple, robust, sensitive, cost-effective) combined with nanomaterials, also called nanobiosensors, are serving as bridge between advanced detection/diagnostics and daily/routine tests. Here we review some of the latest applications of nanobiosensors in diagnostics field.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Photoluminescent lateral flow based on non-radiative energy transfer for protein detection in human serum

  • Zamora Gálvez, Alejandro
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Romero, Javier
  • Merkoçi, Arben|||0000-0003-2486-8085
A new paper-based lateral flow immunoassay configuration was engineered and investigated. The assay is intended for the detection of a model protein in human serum, that is, human immunoglobulin G, with the aim to demonstrate a virtually universal protein detection platform. Once the sample is added in the strip, the analyte is selectively captured by antibody-decorated silica beads (Ab-SiO) onto the conjugate pad and the sample flows by capillarity throughout the strip until reaching the test line, where a sandwich-like immunocomplex takes place due to the presence of antibody-functionalized QDs (Ab-QDs) onto the test line. Eventually, GO is added as a revealing agent and the photoluminescence of those sites protected by the complex Ab-SiO/Antigen/Ab-QDs will not be quenched, whereas those photoluminescent sites directly exposed are expected to be quenched by GO, including the control line, made of bare QDs, reporting that the assay occurred successfully. Hence, the photoluminescence of the test line is modulated by the formation of sandwich-like immunocomplexes. The proposed device achieves a limit of detection (LOD) of 1.35 ng mL in standard buffer, which is lower when compared with conventional lateral flow technology reported by gold nanoparticles, including other amplification strategies. Moreover, the resulting device was proven useful in human serum analysis, achieving a LOD of 6.30 ng mL in this complex matrix. This low-cost disposable and easy-to-use device will prove valuable for portable and automated diagnostics applications, and can be easily transferred to other analytes such as clinically relevant protein biomarkers.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Architecting graphene oxide rolled-up micromotors, a simple paper-based manufacturing technology

  • Baptista Pires, Luis Miguel|||0000-0002-2290-6386
  • Orozco, Jahir|||0000-0001-6249-8092
  • Guardia, Pablo|||0000-0001-9076-4642
  • Merkoçi, Arben|||0000-0003-2486-8085
A graphene oxide rolled-up tube production process is reported using wax-printed membranes for the fabrication of on-demand engineered micromotors at different levels of oxidation, thickness, and lateral dimensions. The resultant graphene oxide rolled-up tubes can show magnetic and catalytic movement within the addition of magnetic nanoparticles or sputtered platinum in the surface of graphene-oxide-modified wax-printed membranes prior to the scrolling process. As a proof of concept, the as-prepared catalytic graphene oxide rolled-up micromotors are successfully exploited for oil removal from water. This micromotor production technology relies on an easy, operator-friendly, fast, and cost-efficient wax-printed paper-based method and may offer a myriad of hybrid devices and applications.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

New binuclear copper(ii) coordination polymer based on mixed pyrazolic and oxalate ligands, Structural characterization and mechanical properties

  • López Marzo, Adaris María|||0000-0001-8552-8637
  • Guerrero, Miguel|||0000-0001-8350-8261
  • Calvet, Teresa|||0000-0002-4058-7171
  • Font-Bardia, Mercè|||0000-0002-7892-8744
  • Pellicer, Eva|||0000-0002-8901-0998
  • Baró, M. D.|||0000-0002-8636-1063
  • Pons Picart, Josefina|||0000-0003-1834-9326
  • Sort, Jordi|||0000-0003-1213-3639
A new inorganic-organic coordination polymer based on a copper(ii) binuclear complex coordinated with pyrazole (L1), 1-(hydroxymethyl)pyrazole) (L2) and oxalate (Ox) ligands has been unexpectedly obtained. The crystal structure of this coordination polymer has been unequivocally determined from single crystal X-ray diffraction. One copper(ii) center (Cu1) is four-coordinated with two nitrogens (N2, L1 and N3, L2), one oxygen (O1, L1) and one chlorine atom, while the other copper(ii) nucleus (Cu2) is five-coordinated with one nitrogen (N1, L1), three oxygens (O1, L2; O2 and O3, Ox) and one chlorine atom, giving slightly distorted square-planar and square-pyramidal geometries, respectively. To the best of our knowledge, such coordination environments have never been previously observed to coexist in the same structure. The terminal chlorine (Cl1) forms the connecting bridge between the planar binuclear [CuCl(Ox)(L1)(L2)] units ending in an attractive structural framework. An extended layered structure staggered along the b-axis is observed in the supramolecular view. Nanoindentation experiments were carried out and relevant mechanical parameters such as hardness, Young's modulus, indentation energies and elastic recovery were determined. Additionally, a comparative analysis between the supramolecular structure and the mechanical properties is reported.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Graphene-based hybrid for enantioselective sensing applications

  • Zor, Erhan
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Alpaydin, Sabri
  • Bingol, Haluk
  • Ersoz, Mustafa
  • Merkoçi, Arben|||0000-0003-2486-8085
Chirality is a major field of research of chemical biology and is essential in pharmacology. Accordingly, approaches for distinguishing between different chiral forms of a compound are of great interest. We report on an efficient and generic enantioselective sensor that is achieved by coupling reduced graphene oxide with γ-cyclodextrin (rGO/γ-CD). The enantioselective sensing capability of the resulting structure was operated in both electrical and optical mode for of tryptophan enantiomers (D-/L-Trp). In this sense, voltammetric and photoluminescence measurements were conducted and the experimental results were compared to molecular docking method. We gain insight into the occurring recognition mechanism with selectivity toward D- and L-Trp as shown in voltammetric, photoluminescence and molecular docking responses. As an enantioselective solid phase on an electrochemical transducer, thanks to the different dimensional interaction of enantiomers with hybrid material, a discrepancy occurs in the Gibbs free energy leading to a difference in oxidation peak potential as observed in electrochemical measurements. The optical sensing principle is based on the energy transfer phenomenon that occurs between photoexcited D-/L-Trp enantiomers and rGO/γ-CD giving rise to an enantioselective photoluminescence quenching due to the tendency of chiral enantiomers to form complexes with γ-CD in different molecular orientations as demonstrated by molecular docking studies. The approach, which is the first demonstration of applicability of molecular docking to show both enantioselective electrochemical and photoluminescence quenching capabilities of a graphene-related hybrid material, is truly new and may have broad interest in combination of experimental and computational methods for enantiosensing of chiral molecules.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Electrochemically reduced graphene and iridium oxide nanoparticles for inhibition-based angiotensin-converting enzyme inhibitor detection

  • Kurbanoglu, Sevinc|||0000-0002-7079-7604
  • Rivas, Lourdes|||0000-0002-1510-5927
  • Ozkan, Sibel A.
  • Merkoçi, Arben|||0000-0003-2486-8085
In this work, a novel biosensor based on electrochemically reduced graphene oxide and iridium oxide nanoparticles for the detection of angiotensin-converting enzyme inhibitor drug, captopril, is presented. For the preparation of the biosensor, tyrosinase is immobilized onto screen printed electrode by using 1-Ethyl-3-(3-dimethylaminopropyl)-carbodiimide and N-Hydroxysuccinimide coupling reagents, in electrochemically reduced graphene oxide and iridium oxide nanoparticles matrix. Biosensor response is characterized towards catechol, in terms of graphene oxide concentration, number of cycles to reduce graphene oxide, volume of iridium oxide nanoparticles and tyrosinase solution. The designed biosensor is used to inhibit tyrosinase activity by Captopril, which is generally used to treat congestive heart failure. It is an angiotensin-converting enzyme inhibitor that operates via chelating copper at the active site of tyrosinase and thioquinone formation. The captopril detections using both inhibition ways are very sensitive with low limits of detection: 0.019 µM and 0.008 µM for chelating copper at the active site of tyrosinase and thioquinone formation, respectively. The proposed methods have been successfully applied in captopril determination in spiked human serum and pharmaceutical dosage forms with acceptable recovery values.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Nanomaterials-based enzyme electrochemical biosensors operating through inhibition for biosensing applications

  • Kurbanoglu, Sevinc|||0000-0002-7079-7604
  • Ozkan, Sibel A.
  • Merkoçi, Arben|||0000-0003-2486-8085
In recent years great progress has been made in applying nanomaterials to design novel biosensors. Use of nanomaterials offers to biosensing platforms exceptional optical, electronic and magnetic properties. Nanomaterials can increase the surface of the transducing area of the sensors that in turn bring an increase in catalytic behaviors. They have large surface-to-volume ratio, controlled morphology and structure that also favor miniaturization, an interesting advantage when the sample volume is a critical issue. Biosensors have great potential for achieving detect-to-protect devices: devices that can be used in detections of pollutants and other treating compounds/analytes (drugs) protecting citizens' life. After a long term focused scientific and financial efforts/supports biosensors are expected now to fulfill their promise such as being able to perform sampling and analysis of complex samples with interest for clinical or environment fields. Among all types of biosensors, enzymatic biosensors, the most explored biosensing devices, have an interesting property, the inherent inhibition phenomena given the enzyme-substrate complex formation. The exploration of such phenomena is making remarkably important their application as research and applied tools in diagnostics. Different inhibition biosensor systems based on nanomaterials modification has been proposed and applied. The role of nanomaterials in inhibition-based biosensors for the analyses of different groups of drugs as well as contaminants such as pesticides, phenolic compounds and others, are discussed in this review. This deep analysis of inhibition-based biosensors that employ nanomaterials will serve researchers as a guideline for further improvements and approaching of these devices to real sample applications so as to reach society needs and such biosensor market demands.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Toward integrated detection and graphene-based removal of contaminants in a lab-on-a-chip platform

  • Chałupniak, Andrzej
  • Merkoçi, Arben|||0000-0003-2486-8085
A novel, miniaturized microfluidic platform was developed for the simultaneous detection and removal of polybrominated diphenyl ethers (PBDEs). The platform consists of a polydimethylsiloxane (PDMS) microfluidic chip for an immunoreaction step, a PDMS chip with an integrated screen-printed electrode (SPCE) for detection, and a PDMS-reduced graphene oxide (rGO) chip for physical adsorption and subsequent removal of PBDE residues. The detection was based on competitive immunoassay-linked binding between PBDE and PBDE modified with horseradish peroxidase (HRP-PBDE) followed by the monitoring of enzymatic oxidation of o-aminophenol (o-AP) using square wave anodic stripping voltammetry (SW-ASV). PBDE was detected with good sensitivity and a limit of detection similar to that obtained with a commercial colorimetric test (0.018 ppb), but with the advantage of using lower reagent volumes and a reduced analysis time. The use of microfluidic chips also provides improved linearity and a better reproducibility in comparison to those obtained with batch-based measurements using screen-printed electrodes. In order to design a detection system suitable for toxic compounds such as PBDEs, a reduced graphene oxide-PDMS composite was developed and optimized to obtain increased adsorption (based on both the hydrophobicity and π-π stacking between rGO and PBDE molecules) compared to those of non-modified PDMS. To the best of our knowledge, this is the first demonstration of electrochemical detection of flame retardants and a novel application of the rGO-PDMS composite in a biosensing system. This system can be easily applied to detect any analyte using the appropriate immunoassay and it supports operation in complex matrices such as seawater.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Magnetic nanoparticle-molecular imprinted polymer, a new impedimetric sensor for tributyltin detection

  • Zamora Gálvez, Alejandro
  • Mayorga-Martinez, Carmen C.|||0000-0003-3687-0035
  • Parolo, Claudio|||0000-0001-9481-4408
  • Pons Picart, Josefina|||0000-0003-1834-9326
  • Merkoçi, Arben|||0000-0003-2486-8085
Recently, molecular imprinted polymers (MIPs) were extensively used for separation and identification of specific molecules, replacing expensive and unstable biological receptors. Nonetheless, their application in electrochemical sensors has not been sufficiently explored. Here we report the use of a MIP as a specific receptor in a new highly sensitive tributyltin (TBT) electrochemical sensor. The sensor combines the specificity, pre-concentration capability and robustness of molecular imprinted polymer attached onto magnetic nanoparticles with the quantitative outputs of impedimetric measurements. The proposed device detects TBT in a concentration range of 5 pM to 5 μM with a low limit of detection (5.37 pM), which is lower than the one recommended for TBT in sea water by the US Environmental Protection Agency (EPA). We believe that this new electrochemical sensor can play an important role in the monitoring of the quality of sea and fresh waters worldwide.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Nanocellulose in Sensing and Biosensing, Nanocellulose in (bio)sensing

  • Golmohammadi, Hamed|||0000-0001-5271-2438
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Naghdi, Tina|||0000-0003-2932-2698
  • Merkoçi, Arben|||0000-0003-2486-8085
Because of its multifunctional character, nanocellulose (NC) is one of the most interesting nature-based nanomaterials and is attracting attention in a myriad of fields such as biomaterials, engineering, biomedicine, opto/electronic devices, nanocomposites, textiles, cosmetics and food products. Moreover, NC offers a plethora of outstanding properties, including inherent renewability, biodegradability, commercial availability, flexibility, printability, low density, high porosity, optical transparency as well as extraordinary mechanical, thermal and physicochemical properties. Consequently, NC holds unprecedented capabilities that are appealing to the scientific, technologic and industrial community. In this review, we highlight how NC is being tailored and applied in (bio)sensing technology, whose results aim at displaying analytical information related to various fields such as clinical/medical diagnostics, environmental monitoring, food safety, physical/mechanical sensing, labeling and bioimaging applications. In fact, NC-based platforms could be considered an emerging technology to fabricate efficient, simple, cost-effective and disposable optical/electrical analytical devices for several (bio)sensing applications including health care, diagnostics, environmental monitoring, food quality control, forensic analysis and physical sensing. We foresee that many of the (bio)sensors that are currently based on plastic, glass or conventional paper platforms will be soon transferred to NC and this generation of (bio)sensing platforms could revolutionize the conventional sensing technology.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Graphene Oxide-Poly(dimethylsiloxane)-Based Lab-on-a-Chip Platform for Heavy-Metals Preconcentration and Electrochemical Detection

  • Chałupniak, Andrzej
  • Merkoçi, Arben|||0000-0003-2486-8085
Herein, we present the application of a novel graphene oxide-poly(dimethylsiloxane) (GO-PDMS) composite in reversible adsorption/desorption, including detection of heavy metals. GO-PDMS was fabricated by simple blending of GO with silicon monomer in the presence of tetrahydrofuran, followed by polymerization initiated upon the addition of curing agent. We found GO concentration, curing agent concentration, pH, and contact time among the most important factors affecting the adsorption of Pb(II) used as a model heavy metal. The mechanism of adsorption is based on surface complexation, where oxygen active groups of negative charge can bind with bivalent metal ions Me(II). To demonstrate a practical application of this material, we fabricated microfluidic lab-on-a-chip platform for heavy-metals preconcentration and detection. This device consists of a screen-printed carbon electrode, a PDMS chip, and a GO-PDMS chip. The use of GO-PDMS preconcentration platform significantly improves the sensitivity of electrochemical detection of heavy metals (an increase of current up to 30× was observed), without the need of modifying electrodes or special reagents addition. Therefore, samples being so far below the limit of detection (0.5 ppb) were successfully detected. This approach is compatible also with real samples (seawater) as ionic strength was found as indifferent for the adsorption process. To the best of our knowledge, GO-PDMS was used for the first time in sensing application. Moreover, due to mechanical resistance and outstanding durability, it can be used multiple times unlike other GO-based platforms for heavy-metals adsorption.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Highly loaded mildly edge-oxidized graphene nanosheet dispersions for large-scale inkjet printing of electrochemical sensors

  • Nagar, Bhawna|||0000-0003-2363-9758
  • Jović, Milica|||0000-0003-3495-2416
  • Bassetto, Víctor Costa
  • Zhu, Yingdi|||0000-0001-5584-3513
  • Pick, Horst|||0000-0003-1347-0223
  • Gómez-Romero, Pedro|||0000-0002-6208-5340
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Girault, Hubert H.|||0000-0001-5573-5774
  • Lesch, Andreas|||0000-0002-4995-2251
Inkjet printing of electrochemical sensors using a highly loaded mildly edge-oxidized graphene nanosheet (EOGN) ink is presented. An ink with 30 mg/mL EOGNs is formulated in a mixture of N-methyl pyrrolidone and propylene glycol with only 30 min of sonication. The absence of additives, such as polymeric stabilizers or surfactants, circumvents reduced electrochemical activity of coated particles and avoids harsh post-printing conditions for additive removal. A single light pulse from a xenon flash lamp dries the printed EGON film within a fraction of a second and creates a compact electrode surface. An accurate coverage with only 30.4 μg of EOGNs per printed layer and cm is achieved. The EOGN films adhere well to flexible polyimide substrates in aqueous solution. Electrochemical measurements were performed using cyclic voltammetry and differential pulse voltammetry. An all inkjet-printed three-electrode living bacterial cell detector is prepared with EOGN working and counter electrodes and silver-based quasi-reference electrode. The presence of E. coli in liquid samples is recorded with four electroactive metabolic activity indicators.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Modulation of population density and size of silver nanoparticles embedded in bacterial cellulose, via ammonia exposure: visual detection of volatile compounds in a piece of plasmonic nanopaper

  • Heli, B.|||0000-0002-1894-5139
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Golmohammadi, Hamed|||0000-0001-5271-2438
  • Ajji, A.
  • Merkoçi, Arben|||0000-0003-2486-8085
The localized surface plasmon resonance exhibited by noble metal nanoparticles can be sensitively tuned by varying their size and interparticle distances. We report that corrosive vapour (ammonia) exposure dramatically reduces the population density of silver nanoparticles (AgNPs) embedded within bacterial cellulose, leading to a larger distance between the remaining nanoparticles and a decrease in the UV-Vis absorbance associated with the AgNP plasmonic properties. We also found that the size distribution of AgNPs embedded in bacterial cellulose undergoes a reduction in the presence of volatile compounds released during food spoilage, modulating the studied nanoplasmonic properties. In fact, such a plasmonic nanopaper exhibits a change in colour from amber to light amber upon the explored corrosive vapour exposure and from amber to a grey or taupe colour upon fish or meat spoilage exposure. These phenomena are proposed as a simple visual detection of volatile compounds in a flexible, transparent, permeable and stable single-use nanoplasmonic membrane, which opens the way to innovative approaches and capabilities in gas sensing and smart packaging.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Molecularly imprinted polymer-decorated magnetite nanoparticles for selective sulfonamide detection

  • Zamora Gálvez, Alejandro
  • Ait-Lahcen, Abdellatif
  • Mercante, Luiza A.
  • Morales-Narváez, Eden|||0000-0002-1536-825X
  • Amine, Aziz
  • Merkoçi, Arben|||0000-0003-2486-8085
Sulfonamides are known not only to be antimicrobial drugs that lead to antimicrobial resistance but also to be chemotherapeutic agents that may be allergenic and potentially carcinogenic, which represents a potentially hazardous compound once present in soil or water. Herein, a hybrid material based on molecularly imprinted polymer (MIP)-decorated magnetite nanoparticles for specific and label-free sulfonamide detection is reported. The composite has been characterized using different spectroscopic and imaging techniques. The magnetic properties of the composite are used to separate, preconcentrate, and manipulate the analyte which is selectively captured by the MIP onto the surface of the composite. Screen printed electrodes have been employed to monitor the impedance levels of the whole material, which is related to the amount of the captured analyte, via electrochemical impedance spectroscopy. This composite-based sensing system exhibits an extraordinary limit of detection of 1 × 10 mol L (2.8 × 10 ppb) (S/N = 3), which is close to those obtained with liquid chromatography and mass spectrometry, and it was demonstrated to screen sulfamethoxazole in a complex matrix such as seawater, where according to the literature sulfonamides content is minimum compared with other environmental samples.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Enhanced detection of quantum dots labeled protein by simultaneous bismuth electrodeposition into microfluidic channel

  • Medina Sánchez, Mariana|||0000-0001-6149-3732
  • Miserere, Sandrine|||0000-0003-2311-621X
  • Cadevall Riera, Miquel|||0000-0002-2968-5862
  • Merkoçi, Arben|||0000-0003-2486-8085
In this study, we propose an electrochemical immunoassay into a disposable microfluidic platform, using quantum dots (QDs) as labels and their enhanced detection using bismuth as an alternative to mercury electrodes. CdSe@ZnS QDs were used to tag human IgG as a model protein and detected through highly sensitive stripping voltammetry of the dissolved metallic component (cadmium in our case). The modification of the screen printed carbon electrodes (SPCEs) was done by a simple electrodeposition of bismuth that was previously mixed with the sample containing QDs. A magneto-immunosandwich assay was performed using a micromixer. A magnet placed at its outlet in order to capture the magnetic beads used as solid support for the immunoassay. SPCEs were integrated at the end of the channel as detector. Different parameters such as bismuth concentration, flow rate, and incubation times, were optimized. The LOD for HIgG in presence of bismuth was 3.5 ng/mL with a RSD of 13.2%. This LOD was about 3.3-fold lower than the one obtained without bismuth. Furthermore, the sensitivity of the system was increased 100-fold respect to experiments carried out with classical screen-printed electrodes, both in presence of bismuth.