Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 12
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Interfacial Phenomena Governing Performance of Graphene Electrodes in Aqueous Electrolyte

  • Delgà-Fernández, Marta|||0000-0001-7434-8593
  • Toral-Lopez, Alejandro|||0000-0001-5612-0536
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Pérez-Marín, Antonio Pablo|||0000-0003-1843-8273
  • Marin, Enrique G|||0000-0002-0302-3764
  • Godoy Medina, Andres|||0000-0002-3014-8765
  • Garrido, Jose|||0000-0001-5621-1067
  • Del Corro, Elena|||0000-0001-6452-9139
There is evidence of the presence of intercalated water between graphene and the substrate in electronic devices. However, a proper understanding of the impact of this phenomenon, which causes important limitations for the optimization of graphene-based devices operating in aqueous electrolytes, is missing. We used graphene-based electrodes on insulating and conducting substrates to evaluate the impact of intercalated water by combining experimental techniques with numerical simulations. Results show that the capacitance of the conductive substrate/graphene electrodes is significantly higher than that of the insulating substrate/graphene ones. Meanwhile, Raman spectroscopy demonstrates that graphene charge modulation with the applied potential is independent of the substrate conductivity. We found that this intriguing behavior is influenced by the water intercalation phenomena and governed by the substrate conductive nature. This work contributes to the understanding of the electric response of graphene-based devices in an aqueous environment and of the methods to measure and model it.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Contribution of physiological dynamics in predicting major depressive disorder severity

  • García Pagès, Esther|||0000-0002-9225-845X
  • Kontaxis, Spyridon|||0000-0002-1297-0691
  • Siddi, Sara|||0000-0002-1494-9028
  • Posadas de Miguel, Mar de
  • Cámara, Concepción de la|||0000-0003-2284-7862
  • Bernal, Maria Luisa
  • Castro Ribeiro, Thaís|||0000-0003-2536-7194
  • Laguna, Pablo|||0000-0003-3434-9254
  • Badiella, Llorenç|||0000-0002-9653-7421
  • Bailón, Raquel|||0000-0003-1272-0550
  • Haro Abad, Josep Maria|||0000-0002-3984-277X
  • Aguiló Llobet, Jordi|||0000-0002-4691-5754
This study aimed to explore the physiological dynamics of cognitive stress in patients with Major Depressive Disorder (MDD) and design a multiparametric model for objectively measuring severity of depression. Physiological signal recordings from 40 MDD patients and 40 healthy controls were collected in a baseline stage, in a stress-inducing stage using two cognitive tests, and in the recovery period. Several features were extracted from electrocardiography, photoplethysmography, electrodermal activity, respiration, and temperature. Differences between values of these features under different conditions were used as indexes of autonomic reactivity and recovery. Finally, a linear model was designed to assess MDD severity, using the Beck Depression Inventory scores as the outcome variable. The performance of this model was assessed using the MDD condition as the response variable. General physiological hyporeactivity and poor recovery from stress predict depression severity across all physiological signals except for respiration. The model to predict depression severity included gender, body mass index, cognitive scores, and mean heart rate recovery, and achieved an accuracy of 78%, a sensitivity of 97% and a specificity of 59%. There is an observed correlation between the behavior of the autonomic nervous system, assessed through physiological signals analysis, and depression severity. Our findings demonstrated that decreased autonomic reactivity and recovery are linked with an increased level of depression. Quantifying the stress response together with a cognitive evaluation and personalization variables may facilitate a more precise diagnosis and monitoring of depression, enabling the tailoring of therapeutic interventions to individual patient needs.
RUC. Repositorio da Universidade da Coruña
Publicación Artículo científico (JournalArticle)

Covalent functionalisation controlled by molecular design for the aptameric recognition of serotonin in graphene-based field-effect transistors

  • Wetzl, Cecilia
  • Brosel, Sergi
  • Carini, Marco
  • Di Silvio, Desiré
  • Illa, Xavi
  • Villa, Rosa
  • Guimerà, Anton
  • Prats Alfonso, Elisabet
  • Prato, Maurizio
  • Criado, Alejandro
[Abastract]: In the last decade, solution-gated graphene field effect transistors (GFETs) showed their versatility in the development of a miniaturized multiplexed platform for electrophysiological recordings and sensing. Due to their working mechanism, the surface functionalisation and immobilisation of receptors are pivotal to ensure the proper functioning of devices. Herein, we present a controlled covalent functionalisation strategy based on molecular design and electrochemical triggering, which provide a monolayer-like functionalisation of micro-GFET arrays retaining the electronic properties of graphenes. The functionalisation layer as a receptor was then employed as the linker for serotonin aptamer conjugation. The micro-GFET arrays display sensitivity toward the target analyte in the micromolar range in a physiological buffer (PBS 10 mM). The sensor allows the in-flow real-time monitoring of serotonin transient concentrations with fast and reversible responses., This work has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement no. 881603 (GrapheneCore3) and no. 785219 (GrapheneCore2). M. P. is AXA Professor and is supported by the European Research Council (ERC-AdG-2019, no. 885323), the Agencia Estatal de Investigación-AEI (“Proyectos I+D+i 2019-Modalidad Retos Investigación”, no. PID2019-108523RB-I00), by grant PRE2020-095099 funded by MCIN/AEI/10.13039/501100011033 and by “ESF Investing in your future.” Part of this work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This project was also funded by the Generalitat de Catalunya (2021SGR00495), by the Spanish Ministerio de Ciencia e Innovación (PID2021-126117NA-I00), by “ERDF A way of making Europe”, and by CIBER-BBN (CB06/01/0049). X. I., R. V., A. G. and E. P.-A. thank the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development. A. C. acknowledges financial support by Grant ED431H 2020/17 funded by Xunta de Galicia, and by Grant RYC2020-030183-I funded by MCIN/AEI/10.13039/501100011033 and “ESF Investing in your future”., Generalitat de Catalunya; 2021SGR00495, Xunta de Galicia; ED431H 2020/17
RUC. Repositorio da Universidade da Coruña
Publicación Artículo científico (JournalArticle)

Single-Step Functionalization Strategy of Graphene Microtransistor Array with Chemically Modified Aptamers for Biosensing Applications

  • Brosel, Sergi
  • Rius, Gemma
  • Aviñó, Ana
  • Nako, Nakatsuka
  • Illa, Xavi
  • Corro, Elena del
  • Delgà-Fernández, Marta
  • Criado, Alejandro
  • Guimerà, Anton
  • Prats Alfonso, Elisabet
[Abstract]: Graphene solution-gated field-effect transistors (gSGFETs) offer high potential for chemical and biochemical sensing applications. Among the current trends to improve this technology, the functionalization processes are gaining relevance for its crucial impact on biosensing performance. Previous efforts are focused on simplifying the attachment procedure from standard multi-step to single-step strategies, but they still suffer from overreaction, and impurity issues and are limited to a particular ligand. Herein, a novel strategy for single-step immobilization of chemically modified aptamers with fluorenylmethyl and acridine moieties, based on a straightforward synthetic route to overcome the aforementioned limitations is presented. This approach is benchmarked versus a standard multi-step strategy using thrombin as detection model. In order to assess the reliability of the functionalization strategies 48-gSGFETs arrays are employed to acquire large datasets with multiple replicas. Graphene surface characterization demonstrates robust and higher efficiency in the chemical coupling of the aptamers with the single-step strategy, while the electrical response evaluation validates the sensing capability, allowing to implement different alternatives for data analysis and reduce the sensing variability. In this work, a new tool capable of overcome the functionalization challenges of graphene surfaces is provided, paving the way toward the standardization of gSGFETs for biosensing purposes., This work has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement no. 881603 (GrapheneCore3) and no. 785219 (GrapheneCore2). M. P. is AXA Professor and is supported by the European Research Council (ERC-AdG-2019, no. 885323), the Agencia Estatal de Investigación-AEI (“Proyectos I+D+i 2019-Modalidad Retos Investigación”, no. PID2019-108523RB-I00), by grant PRE2020-095099 funded by MCIN/AEI/10.13039/501100011033 and by “ESF Investing in your future.” Part of this work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This project was also funded by the Generalitat de Catalunya (2021SGR00495), by the Spanish Ministerio de Ciencia e Innovación (PID2021-126117NA-I00), by “ERDF A way of making Europe”, and by CIBER-BBN (CB06/01/0049). X. I., R. V., A. G. and E. P.-A. thank the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development. A. C. acknowledges financial support by Grant ED431H 2020/17 funded by Xunta de Galicia, and by Grant RYC2020-030183-I funded by MCIN/AEI/10.13039/501100011033 and “ESF Investing in your future”., Generalitat de Catalunya; 2021SGR00495
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Chronic full-band recordings with graphene microtransistors as neural interfaces for discrimination of brain states

  • Camassa, A
  • Barbero-Castillo, Almudena
  • Bosch, M
  • Dasilva, M
  • Masvidal Codina, Eduard
  • Villa, Rosa
  • Guimerà-Brunet, Anton
  • Sanchez-Vives, M V
Brain states such as sleep, anesthesia, wakefulness, or coma are characterized by specific patterns of cortical activity dynamics, from local circuits to full-brain emergent properties. We previously demonstrated that full-spectrum signals, including the infraslow component (DC, direct current-coupled), can be recorded acutely in multiple sites using flexible arrays of graphene solution-gated field-effect transistors (gSGFETs). Here, we performed chronic implantation of 16-channel gSGFET arrays over the rat cerebral cortex and recorded full-band neuronal activity with two objectives: (1) to test the long-term stability of implanted devices; and (2) to investigate full-band activity during the transition across different levels of anesthesia. First, we demonstrate it is possible to record full-band signals with stability, fidelity, and spatiotemporal resolution for up to 5.5 months using chronic epicortical gSGFET implants. Second, brain states generated by progressive variation of levels of anesthesia could be identified as traditionally using the high-pass filtered (AC, alternating current-coupled) spectrogram: from synchronous slow oscillations in deep anesthesia through to asynchronous activity in the awake state. However, the DC signal introduced a highly significant improvement for brain-state discrimination: the DC band provided an almost linear information prediction of the depth of anesthesia, with about 85% precision, using a trained algorithm. This prediction rose to about 95% precision when the full-band (AC + DC) spectrogram was taken into account. We conclude that recording infraslow activity using gSGFET interfaces is superior for the identification of brain states, and further supports the preclinical and clinical use of graphene neural interfaces for long-term recordings of cortical activity., This research has been funded by the European Union's Horizon 2020 research and innovation programme under Grant Agreement No. 881603 (GrapheneCore3) and No. 785219 (GrapheneCore2) to all teams. The IDIBAPS team was also funded by CORTICOMOD PID2020-112947RB-I00 funded by MCIN/AEI/10.13039/501100011033 and by Departament de Recerca i Universitats de la Generalitat de Catalunya (AGAUR 2021-SGR-01165). IDIBAPS is funded by the CERCA program (Generalitat de Catalunya). The fabrication of the graphene-based solution-gated field-effect transistors (gSGFETs) arrays has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. C. N. M. also acknowledge funding from the Departament de Recerca i Universitats de la Generalitat de Catalunya (2021SGR00495), by the Spanish MICIN PID2021-126117NA-I00, and by CIBER-BBN (CB06/01/0049). The authors acknowledge the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development. Thanks to Amin Samipour for comments and to Tony Donegan for language editing., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Recording physiological and pathological cortical activity and exogenous electric fields using graphene microtransistor arrays in vitro

  • Cancino-Fuentes, Nathalia
  • Manasanch, Arnau
  • Covelo, Joana
  • Suarez-Perez, Alex
  • Fernández, Enrique
  • Matsoukis, Stratis
  • Guger, Christoph
  • Illa, Xavi
  • Guimerà-Brunet, Anton
  • Sanchez-Vives, Maria V.
Graphene-based solution-gated field-effect transistors (gSGFETs) allow the quantification of the brain's full-band signal. Extracellular alternating current (AC) signals include local field potentials (LFP, population activity within a reach of hundreds of micrometers), multiunit activity (MUA), and ultimately single units. Direct current (DC) potentials are slow brain signals with a frequency under 0.1 Hz, and commonly filtered out by conventional AC amplifiers. This component conveys information about what has been referred to as "infraslow" activity. We used gSGFET arrays to record full-band patterns from both physiological and pathological activity generated by the cerebral cortex. To this end, we used an in vitro preparation of cerebral cortex that generates spontaneous rhythmic activity, such as that occurring in slow wave sleep. This examination extended to experimentally induced pathological activities, including epileptiform discharges and cortical spreading depression. Validation of recordings obtained via gSGFETs, including both AC and DC components, was accomplished by cross-referencing with well-established technologies, thereby quantifying these components across different activity patterns. We then explored an additional gSGFET potential application, which is the measure of externally induced electric fields such as those used in therapeutic neuromodulation in humans. Finally, we tested the gSGFETs in human cortical slices obtained intrasurgically. In conclusion, this study offers a comprehensive characterization of gSGFETs for brain recordings, with a focus on potential clinical applications of this emerging technology., This research has been funded by the European Union's Horizon 2020 research and innovation programme under Grant Agreement No. 881603 (GrapheneCore3) and No. 785219 (GrapheneCore2) to all teams. The IDIBAPS team was also funded by CORTICOMOD PID2020-112947RB-I00 funded by MCIN/AEI/10.13039/501100011033 and by Departament de Recerca i Universitats de la Generalitat de Catalunya (AGAUR 2021-SGR-01165). IDIBAPS is funded by the CERCA program (Generalitat de Catalunya). The IDIBAPS team thanks the Hospital Clinic of Barcelona for the active collaboration to obtain human tissue (Drs. Roldán, Conde, Rumiá and Carreño). J. C. is funded by EU Horizon 2020 Marie Skłodowska-Curie No 860563 (euSNN MSCA-ITN). The fabrication of the gSGFET arrays made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. C. N. M. also acknowledge funding from the Generalitat de Catalunya (2021SGR00495), by the Spanish MICIN PID2021-126117NA-I00, and by CIBER-BBN (CB06/01/0049). The authors acknowledge the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Concurrent functional ultrasound imaging with graphene-based DC-coupled electrophysiology as a platform to study slow brain signals and cerebral blood flow under control and pathophysiological brain states

  • Zhang, Julie M.
  • Masvidal Codina, Eduard
  • Nguyen, Diep
  • Illa, Xavi
  • Degardin, Julie
  • Goulet, Ruben
  • Prats Alfonso, Elisabet
  • Matsoukis, Stratis
  • Guger, Christoph
  • Garrido, Jose A.
  • Picaud, Serge
  • Guimerà-Brunet, Anton
  • Wykes, Rob C.
Current methodology used to investigate how shifts in brain states associated with regional cerebral blood volume (CBV) change in deep brain areas, are limited by either the spatiotemporal resolution of the CBV techniques, and/or compatibility with electrophysiological recordings; particularly in relation to spontaneous brain activity and the study of individual events. Additionally, infraslow brain signals (<0.1 Hz), including spreading depolarisations, DC-shifts and infraslow oscillations (ISO), are poorly captured by traditional AC-coupled electrographic recordings; yet these very slow brain signals can profoundly change CBV. To gain an improved understanding of how infraslow brain signals couple to CBV we present a new method for concurrent CBV with wide bandwidth electrophysiological mapping using simultaneous functional ultrasound imaging (fUS) and graphene-based field effect transistor (gFET) DC-coupled electrophysiological acquisitions. To validate the feasibility of this methodology visually-evoked neurovascular coupling (NVC) responses were examined. gFET recordings are not affected by concurrent fUS imaging, and epidural placement of gFET arrays within the imaging window did not deteriorate fUS signal quality. To examine directly the impact of infra-slow potential shifts on CBV, cortical spreading depolarisations (CSDs) were induced. A biphasic pattern of decreased, followed by increased CBV, propagating throughout the ipsilateral cortex, and a delayed decrease in deeper subcortical brain regions was observed. In a model of acute seizures, CBV oscillations were observed prior to seizure initiation. Individual seizures occurred on the rising phase of both infraslow brain signal and CBV oscillations. When seizures co-occurred with CSDs, CBV responses were larger in amplitude, with delayed CBV decreases in subcortical structures. Overall, our data demonstrate that gFETs are highly compatible with fUS and allow concurrent examination of wide bandwidth electrophysiology and CBV. This graphene-enabled technological advance has the potential to improve our understanding of how infraslow brain signals relate to CBV changes in control and pathological brain states., This research was funded by the European Union's Horizon 2020 research and innovation programme under grant agreement no. 881603 (Graphene flagship Core 3). This project has also received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement no. 861423 (enTRAIN Vision). We acknowledge the LabEx LIFESENSES (ANR-10-LABX-65) and IHU FOReSIGHT (ANR-18-IAHU-01). RW holds a Senior Research Fellowship funded by the Worshipful Company of Pewterers. ICN2 is supported by the Severo Ochoa Centres of Excellence programme (Grant CEX2021-001214-S), funded by MCIN/AEI/10.13039.501100011033, and by the CERCA Programme of Generalitat de Catalunya. E. M. C. acknowledges grant FJC2021-046601-I funded by Agencia Estatal de Investigación of Spain and the European Union NextGenerationEU/PRTR. This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research has been also supported by funding from the Generalitat de Catalunya (2021SGR00495), MCIN/AEI/10.13039/501100011033 and “ERDF A way of making Europe” (grant PID2021-126117NA-I00), and the “European Union NextGenerationEU/PRTR”, (grant PLEC2022-009232), and CIBER-Consorcio Centro de Investigación Biomédica en Red-(CB06/01/0049), Instituto de Salud Carlos III, Ministerio de Ciencia e Innovación., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Psychosomatic response to acute emotional stress in healthy students

  • García Pagès, E.
  • Arza, A.
  • Lázaro, J.
  • Puig, C.
  • Castro, T.
  • Ottaviano, M.
  • Arredondo, M. T.
  • Bernal, M. L.
  • López-Antón, R.
  • De La Cámara, C.
  • Gil, E.
  • Laguna, P.
  • Bailón, R.
  • Aguiló, J.
  • Garzón-Rey, J. M.
The multidimensionality of the stress response has shown the complexity of this phenomenon and therefore the impossibility of finding a unique biomarker among the physiological variables related to stress. An experimental study was designed and performed to guarantee the correct synchronous and concurrent measure of psychometric tests, biochemical variables and physiological features related to acute emotional stress. The population studied corresponds to a group of 120 university students between 20 and 30 years of age, with healthy habits and without a diagnosis of chronic or psychiatric illnesses. Following the protocol of the experimental pilot, each participant reached a relaxing state and a stress state in two sessions of measurement for equivalent periods. Both states are correctly achieved evidenced by the psychometric test results and the biochemical variables. A Stress Reference Scale is proposed based on these two sets of variables. Then, aiming for a non-invasive and continuous approach, the Acute Stress Model correlated to the previous scale is also proposed, supported only by physiological signals. Preliminary results support the feasibility of measuring/quantifying the stress level. Although the results are limited to the population and stimulus type, the procedure and methodological analysis used for the assessment of acute stress in young people can be extrapolated to other populations and types of stress.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Contribution of physiological dynamics in predicting major depressive disorder severity

  • Pagès, Esther García
  • Kontaxis, Spyridon
  • Siddi, Sara
  • Posadas de Miguel, Mar
  • Cámara, Concepción de la
  • Bernal, Maria Luisa
  • Ribeiro, Thais Castro
  • Laguna, Pablo
  • Badiella, Llorenç
  • Bailón, Raquel
  • Haro, Josep Maria
  • Aguiló, Jordi
This study aimed to explore the physiological dynamics of cognitive stress in patients with Major Depressive Disorder (MDD) and design a multiparametric model for objectively measuring severity of depression. Physiological signal recordings from 40 MDD patients and 40 healthy controls were collected in a baseline stage, in a stress‐inducing stage using two cognitive tests, and in the recovery period. Several features were extracted from electrocardiography, photoplethysmography, electrodermal activity, respiration, and temperature. Differences between values of these features under different conditions were used as indexes of autonomic reactivity and recovery. Finally, a linear model was designed to assess MDD severity, using the Beck Depression Inventory scores as the outcome variable. The performance of this model was assessed using the MDD condition as the response variable. General physiological hyporeactivity and poor recovery from stress predict depression severity across all physiological signals except for respiration. The model to predict depression severity included gender, body mass index, cognitive scores, and mean heart rate recovery, and achieved an accuracy of 78%, a sensitivity of 97% and a specificity of 59%. There is an observed correlation between the behavior of the autonomic nervous system, assessed through physiological signals analysis, and depression severity. Our findings demonstrated that decreased autonomic reactivity and recovery are linked with an increased level of depression. Quantifying the stress response together with a cognitive evaluation and personalization variables may facilitate a more precise diagnosis and monitoring of depression, enabling the tailoring of therapeutic interventions to individual patient needs.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damia|||0000-0001-8558-986X
  • Walston, Steven T.|||0000-0003-4567-8926
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Illa, Xavi|||0000-0002-3212-1128
  • Rodríguez-Meana, Bruno|||0000-0003-0052-7446
  • Del Valle, Jaume|||0000-0002-6703-8244
  • Hayward, Andrew
  • Dodd, Abbie
  • Loret, Thomas|||0000-0001-9171-9819
  • Prats-Alfonso, Elisabet
  • de la Oliva, Natalia|||0000-0002-1263-2705
  • Palma, Marie
  • Del Corro, Elena|||0000-0001-6452-9139
  • del Pilar Bernicola, María
  • Rodríguez-Lucas, Elisa
  • Gener, Thomas|||0000-0001-9209-9228
  • de la Cruz, Jose Manuel
  • Torres-Miranda, Miguel
  • Duvan, Fikret Taygun|||0000-0002-3377-9351
  • Ria, Nicola|||0000-0002-0082-0952
  • Sperling, Justin R.|||0000-0002-1708-2474
  • Martí-Sánchez, Sara|||0000-0003-4283-1489
  • Spadaro, Maria Chiara|||0000-0002-6540-0377
  • Hébert, Clément|||0000-0001-9667-033X
  • Savage, Sinead|||0000-0002-1761-9390
  • Arbiol i Cobos, Jordi|||0000-0002-0695-1726
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Puig, Maria Victoria|||0000-0002-1490-4153
  • Yvert, Blaise|||0000-0002-8850-7935
  • Navarro, X. (Xavier)|||0000-0001-9849-902X
  • Kostarelos, Kostas|||0000-0002-2224-6672
  • Garrido, Jose|||0000-0001-5621-1067
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm ). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Single-Step Functionalization Strategy of Graphene Microtransistor Array with Chemically Modified Aptamers for Biosensing Applications

  • Brosel-Oliu, Sergi
  • Rius, Gemma|||0000-0003-0552-1043
  • Aviñó, Ana|||0000-0003-3047-738X
  • Nakatsuka, Nako
  • Illa, Xavi|||0000-0002-3212-1128
  • Del Corro, Elena|||0000-0001-6452-9139
  • Delgà-Fernández, Marta|||0000-0001-7434-8593
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Rodríguez, Natalia
  • Merino, Juan Pedro
  • Criado, Alejandro|||0000-0002-9732-513X
  • Prato, Maurizio|||0000-0002-8869-8612
  • Tkatchenko, Raphaela
  • Eritja, Ramon|||0000-0001-5383-9334
  • Godignon, Philippe
  • Garrido, Jose|||0000-0001-5621-1067
  • Villa, Rosa|||0000-0003-2735-3204
  • Guimerà, Anton
  • Prats-Alfonso, Elisabet
Graphene solution-gated field-effect transistors (gSGFETs) offer high potential for chemical and biochemical sensing applications. Among the current trends to improve this technology, the functionalization processes are gaining relevance for its crucial impact on biosensing performance. Previous efforts are focused on simplifying the attachment procedure from standard multi-step to single-step strategies, but they still suffer from overreaction, and impurity issues and are limited to a particular ligand. Herein, a novel strategy for single-step immobilization of chemically modified aptamers with fluorenylmethyl and acridine moieties, based on a straightforward synthetic route to overcome the aforementioned limitations is presented. This approach is benchmarked versus a standard multi-step strategy using thrombin as detection model. In order to assess the reliability of the functionalization strategies 48-gSGFETs arrays are employed to acquire large datasets with multiple replicas. Graphene surface characterization demonstrates robust and higher efficiency in the chemical coupling of the aptamers with the single-step strategy, while the electrical response evaluation validates the sensing capability, allowing to implement different alternatives for data analysis and reduce the sensing variability. In this work, a new tool capable of overcome the functionalization challenges of graphene surfaces is provided, paving the way toward the standardization of gSGFETs for biosensing purposes.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Ethanol Solvation of Polymer Residues in Graphene Solution-Gated Field Effect Transistors

  • Merino, Juan Pedro
  • Brosel-Oliu, Sergi
  • Rius, Gemma|||0000-0003-0552-1043
  • Illa, Xavi|||0000-0002-3212-1128
  • Vázque Sulleiro, Manuel|||0000-0002-9688-7771
  • Del Corro, Elena|||0000-0001-6452-9139
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Bonaccini Calia, Andrea|||0000-0002-7873-4296
  • Garrido, Jose|||0000-0001-5621-1067
  • Villa, Rosa|||0000-0003-2735-3204
  • Guimerà-Brunet, Anton
  • Prato, Maurizio|||0000-0002-8869-8612
  • Criado, Alejandro|||0000-0002-9732-513X
  • Prats Alfonso, Elisabet|||0000-0002-7320-1896
The persistence of photoresist residues from microfabrication procedures causes significant obstacles in the technological advancement of graphene-based electronic devices. These residues induce undesired chemical doping effects, diminish carrier mobility, and deteriorate the signal-to-noise ratio, making them critical in certain contexts, including sensing and electrical recording applications. In graphene solution-gated field-effect transistors (gSGFETs), the presence of polymer contaminants makes it difficult to perform precise electrical measurements, introducing response variability and calibration challenges. Given the absence of viable short to midterm alternatives to polymer-intensive microfabrication techniques, a postpatterning treatment involving THF and ethanol solvents was evaluated, with ethanol being the most effective, environmentally sustainable, and safe method for residue removal. Employing a comprehensive analysis with XPS, AFM, and Raman spectroscopy, together with electrical characterization, we investigated the influence of residual polymers on graphene surface properties and transistor functionality. Ethanol treatment exhibited a pronounced enhancement in gSGFET performance, as evidenced by a shift in the charge neutrality point and reduced dispersion. This systematic cleaning methodology holds the potential to improve the reproducibility and precision in the manufacturing of graphene devices. Particularly, by using ethanol for residue removal, we align our methodology with the principles of green chemistry, minimizing environmental impact while advancing diverse graphene technology applications.