Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 12
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

The impact of graphene oxide nanosheet lateral dimensions on the electrochemical performance of nanoporous graphene-based electrodes

  • Bernicola, María del Pilar|||0000-0002-8124-2567
  • Madrid-Gimeno, Miquel
  • Murillo Cremaes, Nerea
  • Battisti, Tommaso
  • Lozano, Neus|||0000-0002-9026-1743
  • Kostarelos, Kostas|||0000-0002-2224-6672
  • Garrido, Jose|||0000-0001-5621-1067
  • Del Corro, Elena|||0000-0001-6452-9139
Electrodes based on nanoporous reduced graphene oxide (rGO) have been developed as the interfacing component in different designs of neural implants in a variety of therapeutic and monitoring applications. The starting graphene oxide (GO) nanosheets lateral dimensions influenced the staking order, roughness and thickness of the derived rGO films, including the formation of nanochannels. Apart from the morphological differences observed, the GO lateral dimension also impacted on the film conductivity, and on the overall electrochemical performance of the rGO electrodes. While electrodes fabricated from nano-scale GO sheets (us-GO) only showed diffusion-limited impedance in the high frequency regime, the electrical response of electrodes from micron-scale GO sheets (L-GO) was limited by diffusion in the whole frequency range due to a less disordered nanoporous film. At 1 kHz, us-GO electrodes, due to their larger capacitance, presented a higher charge injection limit (Qinj.l.) than L-GO electrodes. Due to the higher conductivity of L-GO, electrodes exhibited half the ohmic drop (IR) of electrodes made of us-GO,. This work highlights the importance of GO nanosheet engineering to optimize the performance of rGO electrodes in terms of Qinj.l. and IR, two key figures of merit in neuroelectronic applications.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damià
  • Rodríguez Lucas, Elisa
  • Gener, Thomas
  • Puig, Maria Victoria
  • Garrido, Jose A.
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm-2). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing., This work has been funded by the European Union Horizon 2020 Research and Innovation programme under grant agreement number 881603 (Graphene Core3); FLAG-ERA JTC 2021 project RESCUEGRAPH, from the Agencia Estatal de Investigación of Spain PCI2021-122075-2A y PCI2021-122095-2A financiados por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR; TERCEL (RD12/0019/0011), CIBERNED (CB06/05/1105) and CIBER-BBN (CB06/01/0049) funds from the Instituto de Salud Carlos III of Spain, Proyecto PID2020-113663RB-I00 financiado por MCIN/AEI/10.13039/501100011033, from the Generalitat de Catalunya (2021SGR00495) and from the European Union’s Horizon Europe research and innovation programme under grant agreement number 101070865 (MINIGRAPH). The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033, and by the CERCA Programme/Generalitat de Catalunya. D.V. and S.M.-S. have been supported by the International PhD Programme La Caixa–Severo Ochoa (Programa Internacional de Becas ‘la Caixa’–Severo Ochoa). D.V. acknowledges that this work has been done in the framework of a PhD in electrical and telecommunication engineering at the Universitat Autònoma de Barcelona. J.d.V. acknowledges the Ministerio de Economía, Industria y Competitividad of Spain for Juan de la Cierva incorporation fellowship. M.C.S. received funding from the European Union Horizon 2020 under the Marie Sklodowska-Curie grant agreement number 754510 (PROBIST). E.d.C. acknowledges Ayuda RYC2019-027879-I financiada por MCIN/AEI/10.13039/501100011033 y por El FSE invierte en tu futuro. N.R. acknowledges Ayuda PRE2020-093708 financiada por MCIN/AEI/10.13039/501100011033 y por FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. Authors acknowledge M. Ezcurdia for assistance in the bending experiments. S.M.-S and J.A. acknowledge funding from Generalitat de Catalunya 2021SGR00457. This study is part of the Advanced Materials programme and was supported by MCIN with funding from European Union NextGenerationEU (PRTR-C17.I1) and by Generalitat de Catalunya. This work has made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER-BBN at the IMB-CNM. Part of the present work has been performed in the framework of Universitat Autònoma de Barcelona Materials Science PhD programme and Neuroscience PhD programme. The focused ion beam sample preparation was conducted in the Laboratorio de Microscopias Avanzadas at Instituto de Nanociencia de Aragon-Universidad de Zaragoza. Authors acknowledge the LMA-INA for offering access to their instruments and expertise. This study was also financed by grant PID2019-104683RB-I00 funded by MCIN/AEI/10.13039/501100011033 to M.V.P. The authors would like to acknowledge P. Nebot for technical assistance. The authors would also like to thank C. Bullock and C. Bussy for their contributions during the early stages of the project. The University of Manchester Bioimaging and Single Cell Genomics Facility microscopes used in this study were purchased with grants from the UKRI Biotechnology and Biological Sciences Research Council (BBSRC), the Wellcome Trust and the University of Manchester Strategic Fund. The RT97 antibody was obtained from the Developmental Studies Hybridoma Bank developed under the auspices of the NICHD and maintained by the University of Iowa, Department of Biology.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damià
  • Walston, Steven T.
  • Masvidal Codina, Eduard
  • Illa, Xavi
  • Rodríguez-Meana, Bruno
  • Valle, Jaume del
  • Hayward, Andrew
  • Dodd, Abbie
  • Loret, Thomas
  • Prats Alfonso, Elisabet
  • Oliva, Natàlia de la
  • Palma, Marie
  • Del Corro, Elena
  • Bernicola, María del Pilar
  • Rodríguez-Lucas, Elisa
  • Gener, Thomas
  • Cruz, Jose Manuel de la
  • Torres-Miranda, Miguel
  • Duvan, F. Taygun
  • Ria, Nicola
  • Sperling, Justin R.
  • Martí-Sànchez, Sara
  • Spadaro, Maria Chiara
  • Hébert, Clement
  • Savage, Sinead
  • Arbiol, Jordi
  • Guimerà-Brunet, Anton
  • Puig, M. Victoria
  • Yvert, Blaise
  • Navarro, Xavier
  • Kostarelos, Kostas
  • Garrido, Jose A.
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3–5 mC cm−2). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing., This work has been funded by the European Union Horizon 2020 Research and Innovation programme under grant agreement number 881603 (Graphene Core3); FLAG-ERA JTC 2021 project RESCUEGRAPH, from the Agencia Estatal de Investigación of Spain PCI2021-122075-2A y PCI2021-122095-2A financiados por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR; TERCEL (RD12/0019/0011), CIBERNED (CB06/05/1105) and CIBER-BBN (CB06/01/0049) funds from the Instituto de Salud Carlos III of Spain, Proyecto PID2020-113663RB-I00 financiado por MCIN/AEI/10.13039/501100011033, from the Generalitat de Catalunya (2021SGR00495) and from the European Union’s Horizon Europe research and innovation programme under grant agreement number 101070865 (MINIGRAPH). The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033, and by the CERCA Programme/Generalitat de Catalunya. D.V. and S.M.-S. have been supported by the International PhD Programme La Caixa–Severo Ochoa (Programa Internacional de Becas ‘la Caixa’–Severo Ochoa). D.V. acknowledges that this work has been done in the framework of a PhD in electrical and telecommunication engineering at the Universitat Autònoma de Barcelona. J.d.V. acknowledges the Ministerio de Economía, Industria y Competitividad of Spain for Juan de la Cierva incorporation fellowship. M.C.S. received funding from the European Union Horizon 2020 under the Marie Sklodowska-Curie grant agreement number 754510 (PROBIST). E.d.C. acknowledges Ayuda RYC2019-027879-I financiada por MCIN/AEI/10.13039/501100011033 y por El FSE invierte en tu futuro. N.R. acknowledges Ayuda PRE2020-093708 financiada por MCIN/AEI/10.13039/501100011033 y por FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. Authors acknowledge M. Ezcurdia for assistance in the bending experiments. S.M.-S and J.A. acknowledge funding from Generalitat de Catalunya 2021SGR00457. This study is part of the Advanced Materials programme and was supported by MCIN with funding from European Union NextGenerationEU (PRTR-C17.I1) and by Generalitat de Catalunya. This work has made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER-BBN at the IMB-CNM. Part of the present work has been performed in the framework of Universitat Autònoma de Barcelona Materials Science PhD programme and Neuroscience PhD programme. The focused ion beam sample preparation was conducted in the Laboratorio de Microscopias Avanzadas at Instituto de Nanociencia de Aragon-Universidad de Zaragoza. Authors acknowledge the LMA-INA for offering access to their instruments and expertise. This study was also financed by grant PID2019-104683RB-I00 funded by MCIN/AEI/10.13039/501100011033 to M.V.P. The authors would like to acknowledge P. Nebot for technical assistance. The authors would also like to thank C. Bullock and C. Bussy for their contributions during the early stages of the project. The University of Manchester Bioimaging and Single Cell Genomics Facility microscopes used in this study were purchased with grants from the UKRI Biotechnology and Biological Sciences Research Council (BBSRC), the Wellcome Trust and the University of Manchester Strategic Fund. The RT97 antibody was obtained from the Developmental Studies Hybridoma Bank developed under the auspices of the NICHD and maintained by the University of Iowa, Department of Biology., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

On the Electrochemical Activation of Nanoporous Reduced Graphene Oxide Electrodes Studied by In Situ/Operando Electrochemical Techniques

  • Bernicola, María del Pilar
  • Lounasvuori, Mailis
  • Padilla-Pantoja, Jessica
  • Santiso, José
  • Debiemme-Chouvy, Catherine
  • Perrot, Hubert
  • Petit, Tristan
  • Garrido, Jose A.
  • Corro, Elena del
Due to the difficult access of the electrolyte into the nanoconfined space of nanoporous reduced graphene oxide (rGO) electrodes, achieving the optimal electrochemical performance of these devices becomes a challenge. In this work, the dynamics of interfacial-governed phenomena are investigated during a voltage-controlled electrochemical activation of nanoporous rGO electrodes that leads to an enhanced electrochemical performance in terms of areal capacitance and electrochemical impedance. In situ/operando characterization techniques are used to reveal the dynamics of the irreversible material changes introduced during the activation process, including ionic diffusion and water confinement within the nanopores, along with the reduction of oxygenated groups and the decrease of the rGO interlayer distance. Furthermore, operando techniques are used to uncover the origin of the complex polarization-dependent dynamic response of rGO electrodes. The study reveals that the reversible protonation/deprotonation of remaining functional groups and the cation electro-adsorption/desorption process in the graphene basal plane govern the pseudocapacitive performance of nanoporous rGO electrodes. This work brings new understanding of the complex interplay between surface chemistry, ion confinement, and desolvation processes occurring during electrochemical cycling in nanoporous rGO electrodes, offering new insights for designing high-performing electrodes based on nanoporous rGO., Part of the present work has been performed in the framework of Universitat Autònoma de Barcelona Materials Science PhD programme; This work has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement N° 825213 (WASP); the European Union's Horizon 2020 research and innovation programme under grant agreement N° 881603 (GrapheneCore3); the European Union's Horizon 2020 research and innovation programme under grant agreement N° 101070865 (MINIGRAPH); and MCIN/ AEI /10.13039/501100011033 under grant agreement PID2020-113663RB-I00. E.d.C. acknowledges the RYC2019-027879-I Grant funded by MCIN/AEI/10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

The impact of graphene oxide nanosheet lateral dimensions on the electrochemical performance of nanoporous graphene-based electrodes

  • Bernicola, María del Pilar
  • Madrid-Gimeno, Miquel
  • Murillo-Cremaes, Nerea
  • Battisti, Tommaso
  • Lozano, Neus
  • Kostarelos, Kostas
  • Garrido, Jose A.
  • Corro, Elena del
Electrodes based on nanoporous reduced graphene oxide (rGO) have been developed as the interfacing component in different designs of neural implants in a variety of therapeutic and monitoring applications. The starting graphene oxide (GO) nanosheets lateral dimensions influenced the staking order, roughness and thickness of the derived rGO films, including the formation of nanochannels. Apart from the morphological differences observed, the GO lateral dimension also impacted on the film conductivity, and on the overall electrochemical performance of the rGO electrodes. While electrodes fabricated from nano-scale GO sheets (us-GO) only showed diffusion-limited impedance in the high frequency regime, the electrical response of electrodes from micron-scale GO sheets (L-GO) was limited by diffusion in the whole frequency range due to a less disordered nanoporous film. At 1 kHz, us-GO electrodes, due to their larger capacitance, presented a higher charge injection limit (Qinj.l.) than L-GO electrodes. Due to the higher conductivity of L-GO, electrodes exhibited half the ohmic drop (IR) of electrodes made of us-GO. This work highlights the importance of GO nanosheet engineering to optimize the performance of rGO electrodes in terms of Qinj.l. and IR, two key figures of merit in neuroelectronic applications., Part of the present work has been performed in the framework of Universitat Autònoma de Barcelona Materials Science PhD programme. This work has received funding from the European Union's Horizon 2020 Research and Innovation Programme under grant agreement No 825213 (WASP); the European Union's Horizon 2020 research and innovation programme under grant agreement No 881603 (GrapheneCore3); the European Union's Horizon 2020 research and innovation programme under grant agreement No 101070865 (MINIGRAPH); and MCIN/AEI /10.13039/501100011033 under grant agreement PID2020-113663RB-I00. E.d.C. acknowledges the RYC2019-027879-I Grant funded by MCIN/AEI/10.13039/501100011033. The ICN2 is funded by the CERCA programme/Generalitat de Catalunya and has been supported by the Severo Ochoa Centres of Excellence programme [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (SEV-2017-0706), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Flexible graphene-based neurotechnology for high-precision deep brain mapping and neuromodulation in Parkinsonian rats

  • Ria, Nicola
  • Eladly, Ahmed
  • Masvidal Codina, Eduard
  • Illa, Xavi
  • Guimerà-Brunet, Anton
  • Hills, Kate E.
  • Garcia Cortadella, Ramon
  • Duvan, F. Taygun
  • Flaherty, Samuel M.
  • Prokop, Michał
  • Wykes, Rob C.
  • Kostarelos, Kostas
  • Garrido, Jose A.
Deep brain stimulation (DBS) is a neuroelectronic therapy for the treatment of a broad range of neurological disorders, including Parkinson's disease. Current DBS technologies face important limitations, such as large electrode size, invasiveness, and lack of adaptive therapy based on biomarker monitoring. In this study, we investigate the potential benefits of using nanoporous reduced graphene oxide (rGO) technology in DBS, by implanting a flexible high-density array of rGO microelectrodes (25 µm diameter) in the subthalamic nucleus (STN) of healthy and hemi-parkinsonian rats. We demonstrate that these microelectrodes record action potentials with a high signal-to-noise ratio, allowing the precise localization of the STN and the tracking of multiunit-based Parkinsonian biomarkers. The bidirectional capability to deliver high-density focal stimulation and to record high-fidelity signals unlocks the visualization of local neuromodulation of the multiunit biomarker. These findings demonstrate the potential of bidirectional high-resolution neural interfaces to investigate closed-loop DBS in preclinical models., This research was funded by the European Union’s Horizon 2020 research and innovation program under grant agreement no. 881603 (Graphene Flagship Core 3) and the European Union’s Horizon Europe research and innovation program under grant agreement 101070865 (MINIGRAPH). The ICN2 has been supported by the Severo Ochoa Centres of Excellence program [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence program, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033“and by the CERCA Programme of Generalitat de Catalunya. This research is also funded by the Spanish Ministerio de Ciencia e Innovación (PID2020-113663RB-I00) founded by MCIU/AEI/10.13039/ 501100011033 and by “ERDF A way of making Europe”, PLEC2022-009232 and PCI2021-122095-2A, funded by MCIU/AEI/10.13039/501100011033 and the European Union Next-GenerationEU/PRTR. N. R. acknowledges grant PRE2020-093708 founded by MCIU/AEI /10.13039/501100011033 and by “ESF Investing in your future”. E. M. C. acknowledges grant FJC2021-046601-I funded by MCIU/AEI/10.13039/501100011033 and the European Union Next-GenerationEU/PRTR. This work has made use of the SpanishICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research was supported by CIBER -Consorcio Centro de Investigación Biomédica en Red- (CB06/01/0049), Instituto de Salud Carlos III, Ministerio de Ciencia e Innovación. We would like to thank Prof. Alex Casson from the Department of Biomedical Engineering at the University of Manchester for loaning us the potentiostat used in the experiments. The project that gave rise to these results received the support of a fellowship from the”la Caixa” Foundation (ID 100010434). M. P acknowledges grant with fellowship code LCF/BQ/DI21/11860021., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Long-Term Stable Neural Interfaces with Nanoporous Graphene Electrodes and Hybrid Polyimide-Aluminium Oxide Encapsulation

  • Katirtsidis, Georgios Alexandros
  • Illa, Xavi
  • Ria, Nicola
  • Corro, Elena del
  • Masvidal Codina, Eduard
  • Garrido, Jose A.
Graphene-based thin film technology holds great promise for next-generation neural interfaces due to graphene´s electrical, electrochemical, and mechanical properties. However, the long-term reliability of this technology remains a challenge, primarily due to the instability of thin-film encapsulation in physiological environments. While standard ceramic encapsulation is robust, it is not compatible with the miniaturization required for minimally invasive implants. This study demonstrates the successful integration of a hybrid encapsulation strategy, combining polyimide with atomic layer deposited (ALD) Al2O3, with nanoporous reduced graphene oxide (rGO) microelectrodes, resulting in chronically stable graphene-based neural interfaces. The encapsulation robustness is validated using flexible interdigitated electrodes (IDEs) subjected to accelerated aging and continuous electrical stress. IDEs demonstrated stable performance after soaking for over 1.5 years in phosphate buffer saline (PBS) at 57 °C. Nanoporous graphene microelectrodes combined with the proposed encapsulation retained their structural integrity and electrochemical performance after soaking for 377 days in PBS at 57 °C, withstanding 1 billion biphasic pulses at very high charge density (1 mC cm- 2) and hundreds of bending cycles without noticeable performance deterioration. This work establishes a long-term stable graphene-based neural interface combining nanoporous rGO electrodes and a hybrid polyimide/Al2O3 encapsulation, demonstrating a key technology advancement for the use of graphene neural interfaces in chronic brain monitoring and neuromodulation applications., Part of this work has been performed in the framework of Universitat Autonoma de Barcelona Materials Science PhD programme and the MINIGRAPH project. MINIGRAPH project has received funding from the European Union's Horizon Europe research and innovation programme under grant agreement No. 101070865. This work was supported by the Swiss State Secretariat for Education, Research and Innovation (SERI) under contract number 22.00163. ICN2 and IMB-CNM are currently supported by the Severo Ochoa Centres of Excellence and Maria de Maeztu Units of Excellence programme, grant CEX2021-001214-S and grant CEX2023-001397-M, respectively, both funded by MCIN and MCIU/AEI/10.13039.501100011033.″ ICN2 is also supported by the CERCA Programme of Generalitat de Catalunya. This research is also funded by the Spanish Ministerio de Ciencia e Innovación (CNS2023-144492), funded by MCIU/AEI /10.13039/501100011033 and the European Union Next-GenerationEU/PRTR. This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research was supported by CIBER -Consorcio Centro de Investigación Biomédica en Red- (CB06/01/0049), Instituto de Salud Carlos III, Ministerio de Ciencia e Innovación., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), With funding from the Spanish government through the "María de Maeztu Unit of Excellence" accreditation (CEX2023-001397-M), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

An artefact-resilient wide bandwidth bidirectional graphene neural interface

  • Prokop, Michał
  • Esparza-Iaizzo, Martín
  • Masvidal Codina, Eduard
  • Illa, Xavi
  • Codadu, Neela K.
  • Rathore, Daman
  • Ria, Nicola
  • Kostarelos, Kostas
  • Del Corro, Elena
  • Garcia Cortadella, Ramon
  • Wykes, Rob C.
  • Guimerà-Brunet, Anton
  • Garrido, Jose A.
The ability to simultaneously record and modulate neural activity is critical for next-generation bidirectional neural interfaces aiming to enable adaptive neuromodulation therapies for neurological disorders. Active graphene transistor technologies are particularly promising for neural recordings, as they extend the ability to monitor brain activity at very low frequencies and support multiplexed operation for high-density neural interfaces. However, their limited charge injection capacity makes them unsuitable for stimulation. In this work, we present a bidirectional neural interface that combines nanoporous reduced graphene oxide (rGO) microelectrodes for high charge-injection focal stimulation and graphene solution-gated field-effect transistors (gSGFETs) for brain activity monitoring. Using scalable cleanroom microfabrication techniques, we monolithically integrate these two graphene-based technologies into fully flexible neural probes, leveraging their complementary functionalities within a single-device platform. We evaluate the performance of the hybrid devices both in saline and in vivo, with a particular focus on transistor performance during stimulation. Our results demonstrate that the recording capability of this bidirectional neural interface, including the monitoring of infraslow and local field potential activity, is not compromised during stimulation, opening avenues for future development of adaptive infraslow-based neuromodulation therapies., This research was funded by the European Union’s Horizon 2020 research and innovation program under grant agreement no. 881603 (Graphene Flagship Core 3) and the European Union’s Horizon Europe research and innovation program under grant agreement 101070865 (MINIGRAPH) and 101130650 (META-BRAIN). The ICN2 has been supported by the Severo Ochoa Centers of Excellence program [SEV-2017-0706]. ICN2 and IMB-CNM are currently supported by the Severo Ochoa Centers of Excellence and Maria de Maeztu Units of Excellence program, grant CEX2021-001214-S and grant CEX2023- 001397-M, respectively, both funded by MCIN and MCIU/AEI/10.13039.501100011033. ICN2 is also supported by the CERCA Program of Generalitat de Catalunya. This research is also funded by the Spanish Ministerio de Ciencia e Innovación (PID2020−113663RB-I00 and PID2021-126117NA-I00) founded by MCIU/AEI/10.13039/ 501100011033) and by “ERDF A way of making Europe”, PLEC2022-009232, PCI2021-122095-2A and CNS2023-144492, funded by MCIU/AEI /10.13039/501100011033 and the European Union Next-GenerationEU/PRTR. N. R. acknowledges grant PRE2020-093708 founded by MCIN/AEI /10.13039/501100011033 and by FSE. E. M. C. acknowledges grant FJC2021-046601-I funded by Agencia Estatal de Investigacion of Spain and the European Union Next-GenerationEU/PRTR. This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research was supported by CIBER -Consorcio Centro de Investigación Biomédica en Red- (CB06/01/0049), Instituto de Salud Carlos III, Ministerio de Ciencia e Innovación. The project that gave rise to these results received the support of a fellowship from the “la Caixa” Foundation (ID 100010434). M. P. acknowledges grant with fellowship code LCF/BQ/DI21/11860021., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (SEV-2017-0706), With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), With funding from the Spanish government through the "María de Maeztu Unit of Excellence" accreditation (CEX2023-001397-M), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication Data for: "An artefact-resilient wide bandwidth bidirectional graphene neural interface" (V1)

  • Prokop, Michał
  • Masvidal Codina, Eduard
  • Baumann, Fanny
  • Rodríguez Dueñas, Jan
The ability to simultaneously record and modulate neural activity is critical for next-generation bidirectional neural interfaces aiming to enable adaptive neuromodulation therapies for neurological disorders. Active graphene transistor technologies are particularly promising for neural recordings, as they extend the ability to monitor brain activity at very low frequencies and support multiplexed operation for high-density neural interfaces. However, their limited charge injection capacity makes them unsuitable for stimulation. In this work, we present a bidirectional neural interface that combines nanoporous reduced graphene oxide (rGO) microelectrodes for high charge-injection focal stimulation and graphene solution-gated field-effect transistors (gSGFETs) for brain activity monitoring. Using scalable cleanroom microfabrication techniques, we monolithically integrate these two graphene-based technologies into fully flexible neural probes, leveraging their complementary functionalities within a single-device platform. We evaluate the performance of the hybrid devices both in saline and in vivo, with a particular focus on transistor performance during stimulation. Our results demonstrate that the recording capability of this bidirectional neural interface, including the monitoring of infraslow and local field potential activity, is not compromised during stimulation. This work highlights the potential of this hybrid neural interface for both basic neurophysiological and clinical translation use., European Union's Horizon Europe research and innovation programme. "MINIGRAPH" project. Grant number: 101070865. -- Swiss State Secretariat for Education, Research and Innovation. Grant number: 2200163. -- Severo Ochoa Centres of Excellence and Maria de Maeztu Units of Excellence programme. Grant number: CEX2021-001214-S, CEX2023-001397-M, 10.13039.501100011033, With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), With funding from the Spanish government through the "María de Maeztu Unit of Excellence" accreditation (CEX2023-001397-M), Peer reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damià
  • Rodríguez Lucas, Elisa
  • Gener, Thomas
  • Puig, Maria Victoria
  • Garrido, Jose A.
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm-2). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing., This work has been funded by the European Union Horizon 2020 Research and Innovation programme under grant agreement number 881603 (Graphene Core3); FLAG-ERA JTC 2021 project RESCUEGRAPH, from the Agencia Estatal de Investigación of Spain PCI2021-122075-2A y PCI2021-122095-2A financiados por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR; TERCEL (RD12/0019/0011), CIBERNED (CB06/05/1105) and CIBER-BBN (CB06/01/0049) funds from the Instituto de Salud Carlos III of Spain, Proyecto PID2020-113663RB-I00 financiado por MCIN/AEI/10.13039/501100011033, from the Generalitat de Catalunya (2021SGR00495) and from the European Union’s Horizon Europe research and innovation programme under grant agreement number 101070865 (MINIGRAPH). The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033, and by the CERCA Programme/Generalitat de Catalunya. D.V. and S.M.-S. have been supported by the International PhD Programme La Caixa–Severo Ochoa (Programa Internacional de Becas ‘la Caixa’–Severo Ochoa). D.V. acknowledges that this work has been done in the framework of a PhD in electrical and telecommunication engineering at the Universitat Autònoma de Barcelona. J.d.V. acknowledges the Ministerio de Economía, Industria y Competitividad of Spain for Juan de la Cierva incorporation fellowship. M.C.S. received funding from the European Union Horizon 2020 under the Marie Sklodowska-Curie grant agreement number 754510 (PROBIST). E.d.C. acknowledges Ayuda RYC2019-027879-I financiada por MCIN/AEI/10.13039/501100011033 y por El FSE invierte en tu futuro. N.R. acknowledges Ayuda PRE2020-093708 financiada por MCIN/AEI/10.13039/501100011033 y por FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. Authors acknowledge M. Ezcurdia for assistance in the bending experiments. S.M.-S and J.A. acknowledge funding from Generalitat de Catalunya 2021SGR00457. This study is part of the Advanced Materials programme and was supported by MCIN with funding from European Union NextGenerationEU (PRTR-C17.I1) and by Generalitat de Catalunya. This work has made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER-BBN at the IMB-CNM. Part of the present work has been performed in the framework of Universitat Autònoma de Barcelona Materials Science PhD programme and Neuroscience PhD programme. The focused ion beam sample preparation was conducted in the Laboratorio de Microscopias Avanzadas at Instituto de Nanociencia de Aragon-Universidad de Zaragoza. Authors acknowledge the LMA-INA for offering access to their instruments and expertise. This study was also financed by grant PID2019-104683RB-I00 funded by MCIN/AEI/10.13039/501100011033 to M.V.P. The authors would like to acknowledge P. Nebot for technical assistance. The authors would also like to thank C. Bullock and C. Bussy for their contributions during the early stages of the project. The University of Manchester Bioimaging and Single Cell Genomics Facility microscopes used in this study were purchased with grants from the UKRI Biotechnology and Biological Sciences Research Council (BBSRC), the Wellcome Trust and the University of Manchester Strategic Fund. The RT97 antibody was obtained from the Developmental Studies Hybridoma Bank developed under the auspices of the NICHD and maintained by the University of Iowa, Department of Biology.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damia|||0000-0001-8558-986X
  • Walston, Steven T.|||0000-0003-4567-8926
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Illa, Xavi|||0000-0002-3212-1128
  • Rodríguez-Meana, Bruno|||0000-0003-0052-7446
  • Del Valle, Jaume|||0000-0002-6703-8244
  • Hayward, Andrew
  • Dodd, Abbie
  • Loret, Thomas|||0000-0001-9171-9819
  • Prats-Alfonso, Elisabet
  • de la Oliva, Natalia|||0000-0002-1263-2705
  • Palma, Marie
  • Del Corro, Elena|||0000-0001-6452-9139
  • del Pilar Bernicola, María
  • Rodríguez-Lucas, Elisa
  • Gener, Thomas|||0000-0001-9209-9228
  • de la Cruz, Jose Manuel
  • Torres-Miranda, Miguel
  • Duvan, Fikret Taygun|||0000-0002-3377-9351
  • Ria, Nicola|||0000-0002-0082-0952
  • Sperling, Justin R.|||0000-0002-1708-2474
  • Martí-Sánchez, Sara|||0000-0003-4283-1489
  • Spadaro, Maria Chiara|||0000-0002-6540-0377
  • Hébert, Clément|||0000-0001-9667-033X
  • Savage, Sinead|||0000-0002-1761-9390
  • Arbiol i Cobos, Jordi|||0000-0002-0695-1726
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Puig, Maria Victoria|||0000-0002-1490-4153
  • Yvert, Blaise|||0000-0002-8850-7935
  • Navarro, X. (Xavier)|||0000-0001-9849-902X
  • Kostarelos, Kostas|||0000-0002-2224-6672
  • Garrido, Jose|||0000-0001-5621-1067
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm ). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

On the Electrochemical Activation of Nanoporous Reduced Graphene Oxide Electrodes Studied by In Situ/Operando Electrochemical Techniques

  • Bernicola, María del Pilar|||0000-0002-8124-2567
  • Lounasvuori, Mailis|||0000-0001-9738-4642
  • Padilla-Pantoja, Jessica|||0000-0002-7769-7753
  • Santiso, José|||0000-0003-4274-2101
  • Debiemme-Chouvy, Catherine
  • Perrot, Hubert|||0000-0002-3930-2968
  • Petit, Tristan|||0000-0002-6504-072X
  • Garrido, Jose|||0000-0001-5621-1067
  • Del Corro, Elena|||0000-0001-6452-9139
Due to the difficult access of the electrolyte into the nanoconfined space of nanoporous reduced graphene oxide (rGO) electrodes, achieving the optimal electrochemical performance of these devices becomes a challenge. In this work, the dynamics of interfacial-governed phenomena are investigated during a voltage-controlled electrochemical activation of nanoporous rGO electrodes that leads to an enhanced electrochemical performance in terms of areal capacitance and electrochemical impedance. In situ/operando characterization techniques are used to reveal the dynamics of the irreversible material changes introduced during the activation process, including ionic diffusion and water confinement within the nanopores, along with the reduction of oxygenated groups and the decrease of the rGO interlayer distance. Furthermore, operando techniques are used to uncover the origin of the complex polarization-dependent dynamic response of rGO electrodes. The study reveals that the reversible protonation/deprotonation of remaining functional groups and the cation electro-adsorption/desorption process in the graphene basal plane govern the pseudocapacitive performance of nanoporous rGO electrodes. This work brings new understanding of the complex interplay between surface chemistry, ion confinement, and desolvation processes occurring during electrochemical cycling in nanoporous rGO electrodes, offering new insights for designing high-performing electrodes based on nanoporous rGO.