Pasar al contenido principal

NOVEL NANOMATERIALS AND DEVICE CONCEPTS FOR INFORMATION, COMMUNICATION AND QUANTUM TECHNOLOGIES

PRE2020-093708

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprograma Subprograma Estatal de Formación
Convocatoria Contratos Predoctorales
Año convocatoria 2020
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario FUNDACIÓ INSTITUT CATALÀ DE NANOCIÈNCIA I NANOTECNOLOGIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damià
  • Walston, Steven T.
  • Masvidal Codina, Eduard
  • Illa, Xavi
  • Rodríguez-Meana, Bruno
  • Valle, Jaume del
  • Hayward, Andrew
  • Dodd, Abbie
  • Loret, Thomas
  • Prats Alfonso, Elisabet
  • Oliva, Natàlia de la
  • Palma, Marie
  • Del Corro, Elena
  • Bernicola, María del Pilar
  • Rodríguez-Lucas, Elisa
  • Gener, Thomas
  • Cruz, Jose Manuel de la
  • Torres-Miranda, Miguel
  • Duvan, F. Taygun
  • Ria, Nicola
  • Sperling, Justin R.
  • Martí-Sànchez, Sara
  • Spadaro, Maria Chiara
  • Hébert, Clement
  • Savage, Sinead
  • Arbiol, Jordi
  • Guimerà-Brunet, Anton
  • Puig, M. Victoria
  • Yvert, Blaise
  • Navarro, Xavier
  • Kostarelos, Kostas
  • Garrido, Jose A.
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3–5 mC cm−2). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing., This work has been funded by the European Union Horizon 2020 Research and Innovation programme under grant agreement number 881603 (Graphene Core3); FLAG-ERA JTC 2021 project RESCUEGRAPH, from the Agencia Estatal de Investigación of Spain PCI2021-122075-2A y PCI2021-122095-2A financiados por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR; TERCEL (RD12/0019/0011), CIBERNED (CB06/05/1105) and CIBER-BBN (CB06/01/0049) funds from the Instituto de Salud Carlos III of Spain, Proyecto PID2020-113663RB-I00 financiado por MCIN/AEI/10.13039/501100011033, from the Generalitat de Catalunya (2021SGR00495) and from the European Union’s Horizon Europe research and innovation programme under grant agreement number 101070865 (MINIGRAPH). The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033, and by the CERCA Programme/Generalitat de Catalunya. D.V. and S.M.-S. have been supported by the International PhD Programme La Caixa–Severo Ochoa (Programa Internacional de Becas ‘la Caixa’–Severo Ochoa). D.V. acknowledges that this work has been done in the framework of a PhD in electrical and telecommunication engineering at the Universitat Autònoma de Barcelona. J.d.V. acknowledges the Ministerio de Economía, Industria y Competitividad of Spain for Juan de la Cierva incorporation fellowship. M.C.S. received funding from the European Union Horizon 2020 under the Marie Sklodowska-Curie grant agreement number 754510 (PROBIST). E.d.C. acknowledges Ayuda RYC2019-027879-I financiada por MCIN/AEI/10.13039/501100011033 y por El FSE invierte en tu futuro. N.R. acknowledges Ayuda PRE2020-093708 financiada por MCIN/AEI/10.13039/501100011033 y por FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. Authors acknowledge M. Ezcurdia for assistance in the bending experiments. S.M.-S and J.A. acknowledge funding from Generalitat de Catalunya 2021SGR00457. This study is part of the Advanced Materials programme and was supported by MCIN with funding from European Union NextGenerationEU (PRTR-C17.I1) and by Generalitat de Catalunya. This work has made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER-BBN at the IMB-CNM. Part of the present work has been performed in the framework of Universitat Autònoma de Barcelona Materials Science PhD programme and Neuroscience PhD programme. The focused ion beam sample preparation was conducted in the Laboratorio de Microscopias Avanzadas at Instituto de Nanociencia de Aragon-Universidad de Zaragoza. Authors acknowledge the LMA-INA for offering access to their instruments and expertise. This study was also financed by grant PID2019-104683RB-I00 funded by MCIN/AEI/10.13039/501100011033 to M.V.P. The authors would like to acknowledge P. Nebot for technical assistance. The authors would also like to thank C. Bullock and C. Bussy for their contributions during the early stages of the project. The University of Manchester Bioimaging and Single Cell Genomics Facility microscopes used in this study were purchased with grants from the UKRI Biotechnology and Biological Sciences Research Council (BBSRC), the Wellcome Trust and the University of Manchester Strategic Fund. The RT97 antibody was obtained from the Developmental Studies Hybridoma Bank developed under the auspices of the NICHD and maintained by the University of Iowa, Department of Biology., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Engineered graphene material improves the performance of intraneural peripheral nerve electrodes

  • Rodríguez-Meana, Bruno
  • Valle, Jaume del
  • Viana, Damià
  • Walston, Steven T.
  • Ria, Nicola
  • Masvidal Codina, Eduard
  • Garrido, Jose A.
  • Navarro, Xavier
Limb neuroprostheses aim to restore motor and sensory functions in amputated or severely nerve-injured patients. These devices use neural interfaces to record and stimulate nerve action potentials, creating a bidirectional connection with the nervous system. Most neural interfaces are based on standard metal microelectrodes. In this work, a new generation of neural interfaces which replaces metals with engineered graphene, called EGNITE, is tested. In vitro and in vivo experiments are conducted to assess EGNITE biocompatibility. In vitro tests show that EGNITE does not impact cell viability. In vivo, no significant functional decrease or harmful effects are observed. Furthermore, the foreign body reaction to the intraneural implant is similar compared to other materials previously used in neural interfaces. Regarding functionality, EGNITE devices are able to stimulate nerve fascicles, during two months of implant, producing selective muscle activation with about three times less current compared to larger microelectrodes of standard materials. CNAP elicited by electrical stimuli and ENG evoked by mechanical stimuli are recorded with high resolution but are more affected by decreased functionality over time. This work constitutes further proof that graphene-derived materials, and specifically EGNITE, is a promising conductive material of neural electrodes for advanced neuroprostheses., This research was funded by FLAG-ERA JTC 2017 project GRAFIN and FLAG-ERA JTC 2021 project RESCUEGRAPH, by the Agencia Estatal de Investigación of Spain projects PCI2018-093029 and PCI2021-122075; and by CIBERNED (grant CB06/05/1105) and TERAV (RD21/0017/0008) funds from the Instituto de Salud Carlos III of Spain, co-funded by European Union (NextGenerationEU, Recovery, Transformation and Resilience Plan). ICN2 is supported by the Severo Ochoa Centres of Excellence programme (Grant CEX2021-001214-S), funded by MCIN/AEI/10.13039.501100011033, and by the CERCA Programme of Generalitat de Catalunya; and Project PCI2021-122095-2A financed by MCIN/AEI/10.13039/501 100 011 033 and by the European Union NextGenerationEU/PRTR. The RT97 antibody was obtained from the Developmental Studies Hybridoma Bank, created by the NICHD of the NIH and maintained at the University of Iowa, Department of Biology. E.M.C. acknowledges grant FJC2021-046601-I funded by Agencia Estatal de Investigación of Spain and the European Union NextGenerationEU/PRTR. N.R. acknowledges AyudaPRE2020-093708 provided by MCIN/AEI/10.13039/501 100 011 033 and FSE invierte en tu futuro., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damia|||0000-0001-8558-986X
  • Walston, Steven T.|||0000-0003-4567-8926
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Illa, Xavi|||0000-0002-3212-1128
  • Rodríguez-Meana, Bruno|||0000-0003-0052-7446
  • Del Valle, Jaume|||0000-0002-6703-8244
  • Hayward, Andrew
  • Dodd, Abbie
  • Loret, Thomas|||0000-0001-9171-9819
  • Prats-Alfonso, Elisabet
  • de la Oliva, Natalia|||0000-0002-1263-2705
  • Palma, Marie
  • Del Corro, Elena|||0000-0001-6452-9139
  • del Pilar Bernicola, María
  • Rodríguez-Lucas, Elisa
  • Gener, Thomas|||0000-0001-9209-9228
  • de la Cruz, Jose Manuel
  • Torres-Miranda, Miguel
  • Duvan, Fikret Taygun|||0000-0002-3377-9351
  • Ria, Nicola|||0000-0002-0082-0952
  • Sperling, Justin R.|||0000-0002-1708-2474
  • Martí-Sánchez, Sara|||0000-0003-4283-1489
  • Spadaro, Maria Chiara|||0000-0002-6540-0377
  • Hébert, Clément|||0000-0001-9667-033X
  • Savage, Sinead|||0000-0002-1761-9390
  • Arbiol i Cobos, Jordi|||0000-0002-0695-1726
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Puig, Maria Victoria|||0000-0002-1490-4153
  • Yvert, Blaise|||0000-0002-8850-7935
  • Navarro, X. (Xavier)|||0000-0001-9849-902X
  • Kostarelos, Kostas|||0000-0002-2224-6672
  • Garrido, Jose|||0000-0001-5621-1067
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm ). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing.