Pasar al contenido principal

Nanotechnology-enabled advanced microelectronic neural interfaces for biomedical applications

FJC2021-046601-I

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Desarrollar, Atraer y Retener Talento
Subprograma Subprograma Estatal de Formación
Convocatoria Juan de la Cierva Formación
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario FUNDACIÓ INSTITUT CATALÀ DE NANOCIÈNCIA I NANOTECNOLOGIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Graphene-based microelectrodes with bidirectional functionality for next-generation retinal electronic interfaces

  • Duvan, Fikret Taygun|||0000-0002-3377-9351
  • Cunquero, Marina|||0000-0001-8093-8186
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Walston, Steven T.|||0000-0003-4567-8926
  • Marsal, Maria|||0000-0001-9678-8717
  • de la Cruz, Jose Manuel
  • Viana, Damia|||0000-0001-8558-986X
  • Nguyen, Diep
  • Dégardin, Julie
  • Illa, Xavi|||0000-0002-3212-1128
  • Zhang, Julie Meng|||0000-0001-5985-3815
  • Bernicola, María del Pilar|||0000-0002-8124-2567
  • Macias Montero, Jose Gabriel
  • Puigdengoles, Carles|||0000-0002-1372-5452
  • Castro-Olvera, Gustavo|||0000-0001-9843-3581
  • Del Corro, Elena|||0000-0001-6452-9139
  • Dokos, Socrates
  • Chmeissani, Mokhtar|||0000-0002-2287-4791
  • Loza-Alvarez, Pablo|||0000-0002-3129-1213
  • Picaud, Serge|||0000-0002-0548-5145
  • Garrido, Jose|||0000-0001-5621-1067
Neuroelectronic prostheses are being developed for restoring vision at the retinal level in patients who have lost their sight due to photoreceptor loss. The core component of these devices is the electrode array, which enables interfacing with retinal neurons. Generating the perception of meaningful images requires high-density microelectrode arrays (MEAs) capable of precisely activating targeted retinal neurons. Achieving this precision necessitates the downscaling of electrodes to micrometer dimensions. However, miniaturization increases electrode impedance, which poses challenges by limiting the amount of current that can be delivered, thereby impairing the electrode's capability for effective neural modulation. Additionally, it elevates noise levels, reducing the signal quality of the recorded neural activity. This report focuses on evaluating reduced graphene oxide (rGO) based devices for interfacing with the retina, showcasing their potential in vision restoration. Our findings reveal low impedance and high charge injection limit for microscale rGO electrodes, confirming their suitability for developing next-generation high-density retinal devices. We successfully demonstrated bidirectional interfacing with cell cultures and explanted retinal tissue, enabling the identification and modulation of multiple cells' activity. Additionally, calcium imaging allowed real-time monitoring of retinal cell dynamics, demonstrating a significant reduction in activated areas with small-sized electrodes. Overall, this study lays the groundwork for developing advanced rGO-based MEAs for high-acuity visual prostheses.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Concurrent functional ultrasound imaging with graphene-based DC-coupled electrophysiology as a platform to study slow brain signals and cerebral blood flow under control and pathophysiological brain states

  • Zhang, Julie Meng|||0000-0001-5985-3815
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Nguyen, Diep
  • Illa, Xavi|||0000-0002-3212-1128
  • Dégardin, Julie
  • Goulet, Ruben
  • Prats-Alfonso, Elisabet
  • Matsoukis, Stratis
  • Guger, Christoph
  • Garrido, Jose Antonio
  • Picaud, Serge|||0000-0002-0548-5145
  • Guimerà-Brunet, Anton
  • Wykes, Robert C|||0000-0002-6141-6822
Current methodology used to investigate how shifts in brain states associated with regional cerebral blood volume (CBV) change in deep brain areas, are limited by either the spatiotemporal resolution of the CBV techniques, and/or compatibility with electrophysiological recordings; particularly in relation to spontaneous brain activity and the study of individual events. Additionally, infraslow brain signals (<0.1 Hz), including spreading depolarisations, DC-shifts and infraslow oscillations (ISO), are poorly captured by traditional AC-coupled electrographic recordings; yet these very slow brain signals can profoundly change CBV. To gain an improved understanding of how infraslow brain signals couple to CBV we present a new method for concurrent CBV with wide bandwidth electrophysiological mapping using simultaneous functional ultrasound imaging (fUS) and graphene-based field effect transistor (gFET) DC-coupled electrophysiological acquisitions. To validate the feasibility of this methodology visually-evoked neurovascular coupling (NVC) responses were examined. gFET recordings are not affected by concurrent fUS imaging, and epidural placement of gFET arrays within the imaging window did not deteriorate fUS signal quality. To examine directly the impact of infra-slow potential shifts on CBV, cortical spreading depolarisations (CSDs) were induced. A biphasic pattern of decreased, followed by increased CBV, propagating throughout the ipsilateral cortex, and a delayed decrease in deeper subcortical brain regions was observed. In a model of acute seizures, CBV oscillations were observed prior to seizure initiation. Individual seizures occurred on the rising phase of both infraslow brain signal and CBV oscillations. When seizures co-occurred with CSDs, CBV responses were larger in amplitude, with delayed CBV decreases in subcortical structures. Overall, our data demonstrate that gFETs are highly compatible with fUS and allow concurrent examination of wide bandwidth electrophysiology and CBV. This graphene-enabled technological advance has the potential to improve our understanding of how infraslow brain signals relate to CBV changes in control and pathological brain states.
RUC. Repositorio da Universidade da Coruña
Publicación Artículo científico (JournalArticle)

Ethanol Solvation of Polymer Residues in Graphene Solution-Gated Field Effect Transistors

  • Merino, Juan P.
  • Vázquez Sulleiro, Manuel
  • Criado, Alejandro
  • Prato, Maurizio
  • Prats Alfonso, Elisabet
[Abstract] The persistence of photoresist residues from microfabrication procedures causes significant obstacles in the technological advancement of graphene-based electronic devices. These residues induce undesired chemical doping effects, diminish carrier mobility, and deteriorate the signal-to-noise ratio, making them critical in certain contexts, including sensing and electrical recording applications. In graphene solution-gated field-effect transistors (gSGFETs), the presence of polymer contaminants makes it difficult to perform precise electrical measurements, introducing response variability and calibration challenges. Given the absence of viable short to midterm alternatives to polymer-intensive microfabrication techniques, a postpatterning treatment involving THF and ethanol solvents was evaluated, with ethanol being the most effective, environmentally sustainable, and safe method for residue removal. Employing a comprehensive analysis with XPS, AFM, and Raman spectroscopy, together with electrical characterization, we investigated the influence of residual polymers on graphene surface properties and transistor functionality. Ethanol treatment exhibited a pronounced enhancement in gSGFET performance, as evidenced by a shift in the charge neutrality point and reduced dispersion. This systematic cleaning methodology holds the potential to improve the reproducibility and precision in the manufacturing of graphene devices. Particularly, by using ethanol for residue removal, we align our methodology with the principles of green chemistry, minimizing environmental impact while advancing diverse graphene technology applications., This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research was funded by the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 881603 (GrapheneCore3) and No. 785219 (GrapheneCore2). We also acknowledge funding from the Generalitat de Catalunya (2021SGR00495 and 2021SGR001534). G.R. thanks the Ayuda RYC-2016-21412, and E.dC thanks the Ayuda RYC2019-027879-I founded by MCIU/AEI/10.13039/501100011033 and by El FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIU/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. This research was funded by the Spanish Ministerio de Ciencia e Innovación (PID2021-126117NA-I00, PID2020-113663RB-I00, PLEC2022-009232) founded by MCIU/AEI/10.13039/501100011033) and by “ERDF A way of making Europe”, also this work was funded by CIBER-BBN (CB06/01/0049). In addition, this work has been funded by PLEC2022-009232 funded by MCIU/AEI/ 10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. The authors acknowledge the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development. M.V.S. thanks Xunta de Galicia (ED481B-2023-126). A.C. acknowledges financial support by Grant ED431H 2020/17 funded by Xunta de Galicia, and by Grant RYC2020-030183-I funded by MCIN/AEI/10.13039/501100011033 and “ESF Investing in your future”. Part of this work was performed under the Maria de Maeztu Units of Excellence Program grant MDM-2017-0720 funded by MCIN/AEI/10.13039/501100011033 and supported by the Severo Ochoa Centres of Excellence programme [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033. M.P. as recipient of the AXA Chair is grateful to AXA Chair in Nanobiotechnology supported by the AXA Research Fund., Generalitat de Catalunya; 2021SGR00495, Generalitat de Catalunya; 2021SGR001534, Xunta de Galicia; ED481B-2023-126, Xunta de Galicia; ED431H 2020/17
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damià
  • Walston, Steven T.
  • Masvidal Codina, Eduard
  • Illa, Xavi
  • Rodríguez-Meana, Bruno
  • Valle, Jaume del
  • Hayward, Andrew
  • Dodd, Abbie
  • Loret, Thomas
  • Prats Alfonso, Elisabet
  • Oliva, Natàlia de la
  • Palma, Marie
  • Del Corro, Elena
  • Bernicola, María del Pilar
  • Rodríguez-Lucas, Elisa
  • Gener, Thomas
  • Cruz, Jose Manuel de la
  • Torres-Miranda, Miguel
  • Duvan, F. Taygun
  • Ria, Nicola
  • Sperling, Justin R.
  • Martí-Sànchez, Sara
  • Spadaro, Maria Chiara
  • Hébert, Clement
  • Savage, Sinead
  • Arbiol, Jordi
  • Guimerà-Brunet, Anton
  • Puig, M. Victoria
  • Yvert, Blaise
  • Navarro, Xavier
  • Kostarelos, Kostas
  • Garrido, Jose A.
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3–5 mC cm−2). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing., This work has been funded by the European Union Horizon 2020 Research and Innovation programme under grant agreement number 881603 (Graphene Core3); FLAG-ERA JTC 2021 project RESCUEGRAPH, from the Agencia Estatal de Investigación of Spain PCI2021-122075-2A y PCI2021-122095-2A financiados por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR; TERCEL (RD12/0019/0011), CIBERNED (CB06/05/1105) and CIBER-BBN (CB06/01/0049) funds from the Instituto de Salud Carlos III of Spain, Proyecto PID2020-113663RB-I00 financiado por MCIN/AEI/10.13039/501100011033, from the Generalitat de Catalunya (2021SGR00495) and from the European Union’s Horizon Europe research and innovation programme under grant agreement number 101070865 (MINIGRAPH). The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033, and by the CERCA Programme/Generalitat de Catalunya. D.V. and S.M.-S. have been supported by the International PhD Programme La Caixa–Severo Ochoa (Programa Internacional de Becas ‘la Caixa’–Severo Ochoa). D.V. acknowledges that this work has been done in the framework of a PhD in electrical and telecommunication engineering at the Universitat Autònoma de Barcelona. J.d.V. acknowledges the Ministerio de Economía, Industria y Competitividad of Spain for Juan de la Cierva incorporation fellowship. M.C.S. received funding from the European Union Horizon 2020 under the Marie Sklodowska-Curie grant agreement number 754510 (PROBIST). E.d.C. acknowledges Ayuda RYC2019-027879-I financiada por MCIN/AEI/10.13039/501100011033 y por El FSE invierte en tu futuro. N.R. acknowledges Ayuda PRE2020-093708 financiada por MCIN/AEI/10.13039/501100011033 y por FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. Authors acknowledge M. Ezcurdia for assistance in the bending experiments. S.M.-S and J.A. acknowledge funding from Generalitat de Catalunya 2021SGR00457. This study is part of the Advanced Materials programme and was supported by MCIN with funding from European Union NextGenerationEU (PRTR-C17.I1) and by Generalitat de Catalunya. This work has made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER-BBN at the IMB-CNM. Part of the present work has been performed in the framework of Universitat Autònoma de Barcelona Materials Science PhD programme and Neuroscience PhD programme. The focused ion beam sample preparation was conducted in the Laboratorio de Microscopias Avanzadas at Instituto de Nanociencia de Aragon-Universidad de Zaragoza. Authors acknowledge the LMA-INA for offering access to their instruments and expertise. This study was also financed by grant PID2019-104683RB-I00 funded by MCIN/AEI/10.13039/501100011033 to M.V.P. The authors would like to acknowledge P. Nebot for technical assistance. The authors would also like to thank C. Bullock and C. Bussy for their contributions during the early stages of the project. The University of Manchester Bioimaging and Single Cell Genomics Facility microscopes used in this study were purchased with grants from the UKRI Biotechnology and Biological Sciences Research Council (BBSRC), the Wellcome Trust and the University of Manchester Strategic Fund. The RT97 antibody was obtained from the Developmental Studies Hybridoma Bank developed under the auspices of the NICHD and maintained by the University of Iowa, Department of Biology., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Engineered graphene material improves the performance of intraneural peripheral nerve electrodes

  • Rodríguez-Meana, Bruno
  • Valle, Jaume del
  • Viana, Damià
  • Walston, Steven T.
  • Ria, Nicola
  • Masvidal Codina, Eduard
  • Garrido, Jose A.
  • Navarro, Xavier
Limb neuroprostheses aim to restore motor and sensory functions in amputated or severely nerve-injured patients. These devices use neural interfaces to record and stimulate nerve action potentials, creating a bidirectional connection with the nervous system. Most neural interfaces are based on standard metal microelectrodes. In this work, a new generation of neural interfaces which replaces metals with engineered graphene, called EGNITE, is tested. In vitro and in vivo experiments are conducted to assess EGNITE biocompatibility. In vitro tests show that EGNITE does not impact cell viability. In vivo, no significant functional decrease or harmful effects are observed. Furthermore, the foreign body reaction to the intraneural implant is similar compared to other materials previously used in neural interfaces. Regarding functionality, EGNITE devices are able to stimulate nerve fascicles, during two months of implant, producing selective muscle activation with about three times less current compared to larger microelectrodes of standard materials. CNAP elicited by electrical stimuli and ENG evoked by mechanical stimuli are recorded with high resolution but are more affected by decreased functionality over time. This work constitutes further proof that graphene-derived materials, and specifically EGNITE, is a promising conductive material of neural electrodes for advanced neuroprostheses., This research was funded by FLAG-ERA JTC 2017 project GRAFIN and FLAG-ERA JTC 2021 project RESCUEGRAPH, by the Agencia Estatal de Investigación of Spain projects PCI2018-093029 and PCI2021-122075; and by CIBERNED (grant CB06/05/1105) and TERAV (RD21/0017/0008) funds from the Instituto de Salud Carlos III of Spain, co-funded by European Union (NextGenerationEU, Recovery, Transformation and Resilience Plan). ICN2 is supported by the Severo Ochoa Centres of Excellence programme (Grant CEX2021-001214-S), funded by MCIN/AEI/10.13039.501100011033, and by the CERCA Programme of Generalitat de Catalunya; and Project PCI2021-122095-2A financed by MCIN/AEI/10.13039/501 100 011 033 and by the European Union NextGenerationEU/PRTR. The RT97 antibody was obtained from the Developmental Studies Hybridoma Bank, created by the NICHD of the NIH and maintained at the University of Iowa, Department of Biology. E.M.C. acknowledges grant FJC2021-046601-I funded by Agencia Estatal de Investigación of Spain and the European Union NextGenerationEU/PRTR. N.R. acknowledges AyudaPRE2020-093708 provided by MCIN/AEI/10.13039/501 100 011 033 and FSE invierte en tu futuro., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Ethanol solvation of polymer residues in graphene solution-gated field effect transistors

  • Merino, Juan Pedro
  • Brosel-Oliu, Sergi
  • Rius, Gemma
  • Illa, Xavi
  • Vázquez Sulleiro, Manuel
  • Del Corro, Elena
  • Masvidal Codina, Eduard
  • Bonaccini Calia, Andrea
  • Garrido, Jose A.
  • Villa, Rosa
  • Guimerà-Brunet, Anton
  • Prato, Maurizio
  • Criado, Alejandro
  • Prats Alfonso, Elisabet
The persistence of photoresist residues from microfabrication procedures causes significant obstacles in the technological advancement of graphene-based electronic devices. These residues induce undesired chemical doping effects, diminish carrier mobility, and deteriorate the signal-to-noise ratio, making them critical in certain contexts, including sensing and electrical recording applications. In graphene solution-gated field-effect transistors (gSGFETs), the presence of polymer contaminants makes it difficult to perform precise electrical measurements, introducing response variability and calibration challenges. Given the absence of viable short to midterm alternatives to polymer-intensive microfabrication techniques, a postpatterning treatment involving THF and ethanol solvents was evaluated, with ethanol being the most effective, environmentally sustainable, and safe method for residue removal. Employing a comprehensive analysis with XPS, AFM, and Raman spectroscopy, together with electrical characterization, we investigated the influence of residual polymers on graphene surface properties and transistor functionality. Ethanol treatment exhibited a pronounced enhancement in gSGFET performance, as evidenced by a shift in the charge neutrality point and reduced dispersion. This systematic cleaning methodology holds the potential to improve the reproducibility and precision in the manufacturing of graphene devices. Particularly, by using ethanol for residue removal, we align our methodology with the principles of green chemistry, minimizing environmental impact while advancing diverse graphene technology applications., This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research was funded by the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 881603 (GrapheneCore3) and No. 785219 (GrapheneCore2). We also acknowledge funding from the Generalitat de Catalunya (2021SGR00495 and 2021SGR001534). G.R. thanks the Ayuda RYC-2016-21412, and E.dC thanks the Ayuda RYC2019-027879-I founded by MCIU/AEI/10.13039/501100011033 and by El FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIU/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. This research was funded by the Spanish Ministerio de Ciencia e Innovación (PID2021-126117NA-I00, PID2020-113663RB-I00, PLEC2022-009232) founded by MCIU/AEI/10.13039/501100011033) and by “ERDF A way of making Europe”, also this work was funded by CIBER-BBN (CB06/01/0049). In addition, this work has been funded by PLEC2022-009232 funded by MCIU/AEI/ 10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. The authors acknowledge the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development. M.V.S. thanks Xunta de Galicia (ED481B-2023-126). A.C. acknowledges financial support by Grant ED431H 2020/17 funded by Xunta de Galicia, and by Grant RYC2020-030183-I funded by MCIN/AEI/10.13039/501100011033 and “ESF Investing in your future”. Part of this work was performed under the Maria de Maeztu Units of Excellence Program grant MDM-2017-0720 funded by MCIN/AEI/10.13039/501100011033 and supported by the Severo Ochoa Centres of Excellence programme [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033. M.P. as recipient of the AXA Chair is grateful to AXA Chair in Nanobiotechnology supported by the AXA Research Fund., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Graphene-based microelectrodes with bidirectional functionality for next-generation retinal electronic interfaces

  • Duvan, F. Taygun
  • Cunquero, Marina
  • Masvidal Codina, Eduard
  • Walston, Steven T.
  • Marsal, María
  • Cruz, Jose Manuel de la
  • Viana, Damià
  • Nguyen, Diep
  • Degardin, Julie
  • Illa, Xavi
  • Zhang, Julie M.
  • Bernicola, María del Pilar
  • Macías-Montero, José Gabriel
  • Puigdengoles, Carles
  • Castro-Olvera, Gustavo
  • Del Corro, Elena
  • Dokos, Socrates
  • Chmeissani, Mokhtar
  • Loza-Álvarez, Pablo
  • Picaud, Serge
  • Garrido, Jose A.
This article is part of the themed collection: Graphene and 2D Materials in Healthcare., Neuroelectronic prostheses are being developed for restoring vision at the retinal level in patients who have lost their sight due to photoreceptor loss. The core component of these devices is the electrode array, which enables interfacing with retinal neurons. Generating the perception of meaningful images requires high-density microelectrode arrays (MEAs) capable of precisely activating targeted retinal neurons. Achieving this precision necessitates the downscaling of electrodes to micrometer dimensions. However, miniaturization increases electrode impedance, which poses challenges by limiting the amount of current that can be delivered, thereby impairing the electrode's capability for effective neural modulation. Additionally, it elevates noise levels, reducing the signal quality of the recorded neural activity. This report focuses on evaluating reduced graphene oxide (rGO) based devices for interfacing with the retina, showcasing their potential in vision restoration. Our findings reveal low impedance and high charge injection limit for microscale rGO electrodes, confirming their suitability for developing next-generation high-density retinal devices. We successfully demonstrated bidirectional interfacing with cell cultures and explanted retinal tissue, enabling the identification and modulation of multiple cells' activity. Additionally, calcium imaging allowed real-time monitoring of retinal cell dynamics, demonstrating a significant reduction in activated areas with small-sized electrodes. Overall, this study lays the groundwork for developing advanced rGO-based MEAs for high-acuity visual prostheses., The project leading to these results have received funding from “la Caixa” Foundation (ID 100010434), under the agreement LCF/PR/HR19/52160003 (i-VISION), European Unions Horizon 2020 research and innovation programme under grant agreement no. 881603 (Graphene flagship Core3), and French state funds managed by the Agence Nationale de la Recherche (ANR) within Programme Investissements dAvenir, Laboratoire dExcellence (LABEX) LIFESENSES (ANR-10-LABX-0065) and Institut Hospitalo-Universitaire FOReSIGHT (ANR-18-IAHU-0001). We also acknowledge funding from the Generalitat de Catalunya (2021SGR001534). E. D. C. thanks the Ayuda RYC2019-027879-I founded by MCIU/AEI/10.13039/501100011033 and by El FSE invierte en tu futuro. E. M. C. acknowledges Ayuda FJC2021-046601-I financiada por MCIU/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. This research was funded by the Spanish Ministerio de Ciencia e Innovación (PID2020-113663RB-I00) founded by (MCIU/AEI/10.13039/501100011033) and by “ERDF A way of making Europe”. The ICN2 has been supported by the Severo Ochoa Centres of Excellence programme [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033. This project has also received funding from the European Unions Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement no. 861423 (enTRAIN Vision). Part of this work was performed at the Spanish ICTS Network MICRONANOFABS partially supported by MICINN, and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) at the IMB-CNM. DN has received funding from the doctoral school of Cerveau, cognition, comportement (3C) at Sorbonne Université., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Concurrent functional ultrasound imaging with graphene-based DC-coupled electrophysiology as a platform to study slow brain signals and cerebral blood flow under control and pathophysiological brain states

  • Zhang, Julie M.
  • Masvidal Codina, Eduard
  • Nguyen, Diep
  • Illa, Xavi
  • Degardin, Julie
  • Goulet, Ruben
  • Prats Alfonso, Elisabet
  • Matsoukis, Stratis
  • Guger, Christoph
  • Garrido, Jose A.
  • Picaud, Serge
  • Guimerà-Brunet, Anton
  • Wykes, Rob C.
Current methodology used to investigate how shifts in brain states associated with regional cerebral blood volume (CBV) change in deep brain areas, are limited by either the spatiotemporal resolution of the CBV techniques, and/or compatibility with electrophysiological recordings; particularly in relation to spontaneous brain activity and the study of individual events. Additionally, infraslow brain signals (<0.1 Hz), including spreading depolarisations, DC-shifts and infraslow oscillations (ISO), are poorly captured by traditional AC-coupled electrographic recordings; yet these very slow brain signals can profoundly change CBV. To gain an improved understanding of how infraslow brain signals couple to CBV we present a new method for concurrent CBV with wide bandwidth electrophysiological mapping using simultaneous functional ultrasound imaging (fUS) and graphene-based field effect transistor (gFET) DC-coupled electrophysiological acquisitions. To validate the feasibility of this methodology visually-evoked neurovascular coupling (NVC) responses were examined. gFET recordings are not affected by concurrent fUS imaging, and epidural placement of gFET arrays within the imaging window did not deteriorate fUS signal quality. To examine directly the impact of infra-slow potential shifts on CBV, cortical spreading depolarisations (CSDs) were induced. A biphasic pattern of decreased, followed by increased CBV, propagating throughout the ipsilateral cortex, and a delayed decrease in deeper subcortical brain regions was observed. In a model of acute seizures, CBV oscillations were observed prior to seizure initiation. Individual seizures occurred on the rising phase of both infraslow brain signal and CBV oscillations. When seizures co-occurred with CSDs, CBV responses were larger in amplitude, with delayed CBV decreases in subcortical structures. Overall, our data demonstrate that gFETs are highly compatible with fUS and allow concurrent examination of wide bandwidth electrophysiology and CBV. This graphene-enabled technological advance has the potential to improve our understanding of how infraslow brain signals relate to CBV changes in control and pathological brain states., This research was funded by the European Union's Horizon 2020 research and innovation programme under grant agreement no. 881603 (Graphene flagship Core 3). This project has also received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement no. 861423 (enTRAIN Vision). We acknowledge the LabEx LIFESENSES (ANR-10-LABX-65) and IHU FOReSIGHT (ANR-18-IAHU-01). RW holds a Senior Research Fellowship funded by the Worshipful Company of Pewterers. ICN2 is supported by the Severo Ochoa Centres of Excellence programme (Grant CEX2021-001214-S), funded by MCIN/AEI/10.13039.501100011033, and by the CERCA Programme of Generalitat de Catalunya. E. M. C. acknowledges grant FJC2021-046601-I funded by Agencia Estatal de Investigación of Spain and the European Union NextGenerationEU/PRTR. This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research has been also supported by funding from the Generalitat de Catalunya (2021SGR00495), MCIN/AEI/10.13039/501100011033 and “ERDF A way of making Europe” (grant PID2021-126117NA-I00), and the “European Union NextGenerationEU/PRTR”, (grant PLEC2022-009232), and CIBER-Consorcio Centro de Investigación Biomédica en Red-(CB06/01/0049), Instituto de Salud Carlos III, Ministerio de Ciencia e Innovación., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Ethanol Solvation of Polymer Residues in Graphene Solution-Gated Field Effect Transistors, Ethanol solvation of polymer residues in graphene solution-gated field effect transistors JP Merino, S Brosel-Oliu, G Rius, X Illa, MV Sulleiro… - ACS sustainable chemistry & engineering, 2024

  • Merino, Juan Pedro
  • Brosel-Oliu, Sergi
  • Rius, Gemma
  • Illa, Xavi
  • Vázquez Sulleiro, Manuel
  • Del Corro, Elena
  • Masvidal Codina, Eduard
  • Bonaccini Calia, Andrea
  • Garrido, Jose A.
  • Villa, Rosa
  • Guimerà-Brunet, Anton
  • Prato, Maurizio
  • Criado, Alejandro
  • Prats Alfonso, Elisabet
The persistence of photoresist residues from microfabrication procedures causes significant obstacles in the technological advancement of graphene-based electronic devices. These residues induce undesired chemical doping effects, diminish carrier mobility, and deteriorate the signal-to-noise ratio, making them critical in certain contexts, including sensing and electrical recording applications. In graphene solution-gated field-effect transistors (gSGFETs), the presence of polymer contaminants makes it difficult to perform precise electrical measurements, introducing response variability and calibration challenges. Given the absence of viable short to midterm alternatives to polymer-intensive microfabrication techniques, a postpatterning treatment involving THF and ethanol solvents was evaluated, with ethanol being the most effective, environmentally sustainable, and safe method for residue removal. Employing a comprehensive analysis with XPS, AFM, and Raman spectroscopy, together with electrical characterization, we investigated the influence of residual polymers on graphene surface properties and transistor functionality. Ethanol treatment exhibited a pronounced enhancement in gSGFET performance, as evidenced by a shift in the charge neutrality point and reduced dispersion. This systematic cleaning methodology holds the potential to improve the reproducibility and precision in the manufacturing of graphene devices. Particularly, by using ethanol for residue removal, we align our methodology with the principles of green chemistry, minimizing environmental impact while advancing diverse graphene technology applications., This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research was funded by the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 881603 (GrapheneCore3) and No. 785219 (GrapheneCore2). We also acknowledge funding from the Generalitat de Catalunya (2021SGR00495 and 2021SGR001534). G.R. thanks the Ayuda RYC-2016-21412, and E.dC thanks the Ayuda RYC2019-027879-I founded by MCIU/AEI/10.13039/501100011033 and by El FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIU/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. This research was funded by the Spanish Ministerio de Ciencia e Innovación (PID2021-126117NA-I00, PID2020-113663RB-I00, PLEC2022-009232) founded by MCIU/AEI/10.13039/501100011033) and by “ERDF A way of making Europe”, also this work was funded by CIBER-BBN (CB06/01/0049). In addition, this work has been funded by PLEC2022-009232 funded by MCIU/AEI/ 10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. The authors acknowledge the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development. M.V.S. thanks Xunta de Galicia (ED481B-2023-126). A.C. acknowledges financial support by Grant ED431H 2020/17 funded by Xunta de Galicia, and by Grant RYC2020-030183-I funded by MCIN/AEI/10.13039/501100011033 and “ESF Investing in your future”. Part of this work was performed under the Maria de Maeztu Units of Excellence Program grant MDM-2017-0720 funded by MCIN/AEI/10.13039/501100011033 and supported by the Severo Ochoa Centres of Excellence programme [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033. M.P. as recipient of the AXA Chair is grateful to AXA Chair in Nanobiotechnology supported by the AXA Research Fund., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

An artefact-resilient wide bandwidth bidirectional graphene neural interface

  • Prokop, Michał
  • Esparza-Iaizzo, Martín
  • Masvidal Codina, Eduard
  • Illa, Xavi
  • Codadu, Neela K.
  • Rathore, Daman
  • Ria, Nicola
  • Kostarelos, Kostas
  • Del Corro, Elena
  • Garcia Cortadella, Ramon
  • Wykes, Rob C.
  • Guimerà-Brunet, Anton
  • Garrido, Jose A.
The ability to simultaneously record and modulate neural activity is critical for next-generation bidirectional neural interfaces aiming to enable adaptive neuromodulation therapies for neurological disorders. Active graphene transistor technologies are particularly promising for neural recordings, as they extend the ability to monitor brain activity at very low frequencies and support multiplexed operation for high-density neural interfaces. However, their limited charge injection capacity makes them unsuitable for stimulation. In this work, we present a bidirectional neural interface that combines nanoporous reduced graphene oxide (rGO) microelectrodes for high charge-injection focal stimulation and graphene solution-gated field-effect transistors (gSGFETs) for brain activity monitoring. Using scalable cleanroom microfabrication techniques, we monolithically integrate these two graphene-based technologies into fully flexible neural probes, leveraging their complementary functionalities within a single-device platform. We evaluate the performance of the hybrid devices both in saline and in vivo, with a particular focus on transistor performance during stimulation. Our results demonstrate that the recording capability of this bidirectional neural interface, including the monitoring of infraslow and local field potential activity, is not compromised during stimulation, opening avenues for future development of adaptive infraslow-based neuromodulation therapies., This research was funded by the European Union’s Horizon 2020 research and innovation program under grant agreement no. 881603 (Graphene Flagship Core 3) and the European Union’s Horizon Europe research and innovation program under grant agreement 101070865 (MINIGRAPH) and 101130650 (META-BRAIN). The ICN2 has been supported by the Severo Ochoa Centers of Excellence program [SEV-2017-0706]. ICN2 and IMB-CNM are currently supported by the Severo Ochoa Centers of Excellence and Maria de Maeztu Units of Excellence program, grant CEX2021-001214-S and grant CEX2023- 001397-M, respectively, both funded by MCIN and MCIU/AEI/10.13039.501100011033. ICN2 is also supported by the CERCA Program of Generalitat de Catalunya. This research is also funded by the Spanish Ministerio de Ciencia e Innovación (PID2020−113663RB-I00 and PID2021-126117NA-I00) founded by MCIU/AEI/10.13039/ 501100011033) and by “ERDF A way of making Europe”, PLEC2022-009232, PCI2021-122095-2A and CNS2023-144492, funded by MCIU/AEI /10.13039/501100011033 and the European Union Next-GenerationEU/PRTR. N. R. acknowledges grant PRE2020-093708 founded by MCIN/AEI /10.13039/501100011033 and by FSE. E. M. C. acknowledges grant FJC2021-046601-I funded by Agencia Estatal de Investigacion of Spain and the European Union Next-GenerationEU/PRTR. This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research was supported by CIBER -Consorcio Centro de Investigación Biomédica en Red- (CB06/01/0049), Instituto de Salud Carlos III, Ministerio de Ciencia e Innovación. The project that gave rise to these results received the support of a fellowship from the “la Caixa” Foundation (ID 100010434). M. P. acknowledges grant with fellowship code LCF/BQ/DI21/11860021., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (SEV-2017-0706), With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), With funding from the Spanish government through the "María de Maeztu Unit of Excellence" accreditation (CEX2023-001397-M), Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damia|||0000-0001-8558-986X
  • Walston, Steven T.|||0000-0003-4567-8926
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Illa, Xavi|||0000-0002-3212-1128
  • Rodríguez-Meana, Bruno|||0000-0003-0052-7446
  • Del Valle, Jaume|||0000-0002-6703-8244
  • Hayward, Andrew
  • Dodd, Abbie
  • Loret, Thomas|||0000-0001-9171-9819
  • Prats-Alfonso, Elisabet
  • de la Oliva, Natalia|||0000-0002-1263-2705
  • Palma, Marie
  • Del Corro, Elena|||0000-0001-6452-9139
  • del Pilar Bernicola, María
  • Rodríguez-Lucas, Elisa
  • Gener, Thomas|||0000-0001-9209-9228
  • de la Cruz, Jose Manuel
  • Torres-Miranda, Miguel
  • Duvan, Fikret Taygun|||0000-0002-3377-9351
  • Ria, Nicola|||0000-0002-0082-0952
  • Sperling, Justin R.|||0000-0002-1708-2474
  • Martí-Sánchez, Sara|||0000-0003-4283-1489
  • Spadaro, Maria Chiara|||0000-0002-6540-0377
  • Hébert, Clément|||0000-0001-9667-033X
  • Savage, Sinead|||0000-0002-1761-9390
  • Arbiol i Cobos, Jordi|||0000-0002-0695-1726
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Puig, Maria Victoria|||0000-0002-1490-4153
  • Yvert, Blaise|||0000-0002-8850-7935
  • Navarro, X. (Xavier)|||0000-0001-9849-902X
  • Kostarelos, Kostas|||0000-0002-2224-6672
  • Garrido, Jose|||0000-0001-5621-1067
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm ). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Engineered Graphene Material Improves the Performance of Intraneural Peripheral Nerve Electrodes

  • Rodríguez-Meana, Bruno|||0000-0003-0052-7446
  • Del Valle, Jaume|||0000-0002-6703-8244
  • Viana, Damia|||0000-0001-8558-986X
  • Walston, Steven T.|||0000-0003-4567-8926
  • Ria, Nicola|||0000-0002-0082-0952
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Garrido, Jose|||0000-0001-5621-1067
  • Navarro, X. (Xavier)|||0000-0001-9849-902X
Limb neuroprostheses aim to restore motor and sensory functions in amputated or severely nerve-injured patients. These devices use neural interfaces to record and stimulate nerve action potentials, creating a bidirectional connection with the nervous system. Most neural interfaces are based on standard metal microelectrodes. In this work, a new generation of neural interfaces which replaces metals with engineered graphene, called EGNITE, is tested. In vitro and in vivo experiments are conducted to assess EGNITE biocompatibility. In vitro tests show that EGNITE does not impact cell viability. In vivo, no significant functional decrease or harmful effects are observed. Furthermore, the foreign body reaction to the intraneural implant is similar compared to other materials previously used in neural interfaces. Regarding functionality, EGNITE devices are able to stimulate nerve fascicles, during two months of implant, producing selective muscle activation with about three times less current compared to larger microelectrodes of standard materials. CNAP elicited by electrical stimuli and ENG evoked by mechanical stimuli are recorded with high resolution but are more affected by decreased functionality over time. This work constitutes further proof that graphene-derived materials, and specifically EGNITE, is a promising conductive material of neural electrodes for advanced neuroprostheses.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Ethanol Solvation of Polymer Residues in Graphene Solution-Gated Field Effect Transistors

  • Merino, Juan Pedro
  • Brosel-Oliu, Sergi
  • Rius, Gemma|||0000-0003-0552-1043
  • Illa, Xavi|||0000-0002-3212-1128
  • Vázque Sulleiro, Manuel|||0000-0002-9688-7771
  • Del Corro, Elena|||0000-0001-6452-9139
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Bonaccini Calia, Andrea|||0000-0002-7873-4296
  • Garrido, Jose|||0000-0001-5621-1067
  • Villa, Rosa|||0000-0003-2735-3204
  • Guimerà-Brunet, Anton
  • Prato, Maurizio|||0000-0002-8869-8612
  • Criado, Alejandro|||0000-0002-9732-513X
  • Prats Alfonso, Elisabet|||0000-0002-7320-1896
The persistence of photoresist residues from microfabrication procedures causes significant obstacles in the technological advancement of graphene-based electronic devices. These residues induce undesired chemical doping effects, diminish carrier mobility, and deteriorate the signal-to-noise ratio, making them critical in certain contexts, including sensing and electrical recording applications. In graphene solution-gated field-effect transistors (gSGFETs), the presence of polymer contaminants makes it difficult to perform precise electrical measurements, introducing response variability and calibration challenges. Given the absence of viable short to midterm alternatives to polymer-intensive microfabrication techniques, a postpatterning treatment involving THF and ethanol solvents was evaluated, with ethanol being the most effective, environmentally sustainable, and safe method for residue removal. Employing a comprehensive analysis with XPS, AFM, and Raman spectroscopy, together with electrical characterization, we investigated the influence of residual polymers on graphene surface properties and transistor functionality. Ethanol treatment exhibited a pronounced enhancement in gSGFET performance, as evidenced by a shift in the charge neutrality point and reduced dispersion. This systematic cleaning methodology holds the potential to improve the reproducibility and precision in the manufacturing of graphene devices. Particularly, by using ethanol for residue removal, we align our methodology with the principles of green chemistry, minimizing environmental impact while advancing diverse graphene technology applications.