Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Miniaturized multiparametric flexible platform for the simultaneous monitoring of ionic: Application in real urine

  • Moya, Ana
  • Illa, Xavi
  • Giménez, Ignacio
  • Lazo-Fernández, Yoskaly
  • Villa, Rosa
  • Errachid, Abdelhamid
  • Gabriel, Gemma
Biomonitoring is a research topic that has largely relied on cell culture systems. Recently, the development of “Organ-on-a-Chip” (OC) platforms and the need for a continuous monitoring of these systems has increased its interest. However, the biomonitorization in these systems is still at its infancy due to the difficulty to adapt the sensors to microfluidic OC systems. In this work we have fabricated a modular, versatile, scalable, multi-analyte sensing platform, which integrates dissolved oxygen (DO), Na+, K+ and pH sensors for monitoring their concentrations in small volume of biological fluids. The platform is fabricated by means of rapid prototyping techniques using polymeric substrates, and incorporates all the necessary elements to measure the four analytes. It was designed with four gold sensing electrodes, and integrates a gold counter electrode and an Ag/AgCl pseudo-reference electrode for the electrochemical measurements in small volumes (0.83 µL) of samples. The sensors featured good sensitivities of 3.60 ± 0.2 nA (mg L-1) for DO and 69 ± 1 mV decade-1 for pH. Na+ and K+ µISE exhibited sensitivities of 57 ± 1 mV decade-1 and 52 ± 2 mV decade-1, and low limits of detection 5 × 10-6 M and 0.5 × 10-5 M respectively. This platform allows the dynamic measurement of the biological fluids parameters simultaneously, in real time and with a rapid response. The versatility of the platform allows its adaptation in any microfluidic cells culture systems. The novel multi-sensor platform has been validated in controlled buffers and with artificial urine (AU). A proof-of-concept using real mice urine (RU) has been carried out, demonstrating the good behaviour of the multi-sensing platform.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mechanical behavior of surgical meshes for abdominal wall repair: In vivo versus biaxial characterization

  • Simón-Allué, R.
  • Ortillés, A.
  • Calvo, B.
Despite the widespread use of synthetic meshes in the surgical treatment of the hernia pathology, the election criteria of a suitable mesh for specific patient continues to be uncertain. Thus, in this work, we propose a methodology to determine in advance potential disadvantages on the use of certain meshes based on the patient-specific abdominal geometry and the mechanical features of the certain meshes. To that purpose, we have first characterized the mechanical behavior of four synthetic meshes through biaxial tests. Secondly, two of these meshes were implanted in several New Zealand rabbits with a total defect previously created on the center of the abdominal wall. After the surgical procedure, specimen were subjected to in vivo pneumoperitoneum tests to determine the immediate post-surgical response of those meshes after implanted in a healthy specimen. Experimental performance was recorded by a stereo rig with the aim of obtaining quantitative information about the pressure-displacement relation of the abdominal wall. Finally, following the procedure presented in prior works (Simón-Allué et al., 2015, 2017), a finite element model was reconstructed from the experimental measurements and tests were computationally reproduced for the healthy and herniated cases. Simulations were compared and validated with the in vivo behavior and results were given along the abdominal wall in terms of displacements, stresses and strain. Mechanical characterization of the meshes revealed Surgipro TM as the most rigid implant and Neomesh SuperSoft® as the softer, while other two meshes (Neomesh Soft® Neopore®) remained in between. These two meshes were employed in the experimental study and resulted in similar effect in the abdominal wall cavity and both were close to the healthy case. Simulations confirmed this result while showed potential objections in the case of the other two meshes, due to high values in stresses or elongation that may led to discomfort in real tissue. The use of this methodology on human surgery may provide the surgeons with reliable and useful information to avoid certain meshes on specific-patient treatment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Baroreflex sensitivity measured by pulse photoplethysmography

  • Lázaro, Jesús
  • Gil, Eduardo
  • Orini, Michele
  • Laguna, Pablo
  • Bailón, Raquel
Novel methods for assessing baroreflex sensitivity (BRS) using only pulse photoplethysmography (PPG) signals are presented. Proposed methods were evaluated with a data set containing electrocardiogram (ECG), blood pressure (BP), and PPG signals from 17 healthy subjects during a tilt table test. The methods are based on a surrogate of a index, which is defined as the power ratio of RR interval variability (RRV) and that of systolic arterial pressure series variability (SAPV). The proposed a index surrogates use pulse-to-pulse interval series variability (PPV) as a surrogate of RRV, and different morphological features of the PPG pulse which have been hypothesized to be related to BP, as series surrogates of SAPV. A time-frequency technique was used to assess BRS, taking into account the non-stationarity of the protocol. This technique identifies two time-varying frequency bands where RRV and SAPV (or their surrogates) are expected to be coupled: the low frequency (LF, inside 0.04–0.15 Hz range), and the high frequency (HF, inside 0.15–0.4 Hz range) bands. Furthermore, time-frequency coherence is used to identify the time intervals when the RRV and SAPV (or their surrogates) are coupled. Conventional a index based on RRV and SAPV was used as Gold Standard. Spearman correlation coefficients between conventional a index and its PPG-based surrogates were computed and the paired Wilcoxon statistical test was applied in order to assess whether the indices can find significant differences (p < 0.05) between different stages of the protocol. The highest correlations with the conventional a index were obtained by the a-index-surrogate based on PPV and pulse up-slope (PUS), with 0.74 for LF band, and 0.81 for HF band. Furthermore, this index found significant differences between rest stages and tilt stage in both LF and HF bands according to the paired Wilcoxon test, as the conventional a index also did. These results suggest that BRS changes induced by the tilt test can be assessed with high correlation by only a PPG signal using PPV as RRV surrogate, and PPG morphological features as SAPV surrogates, being PUS the most convenient SAPV surrogate among the studied ones.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic dysfunction increases cardiovascular risk in the presence of sleep apnea

  • Milagro, Javier
  • Deviaene, Margot
  • Gil, Eduardo
  • Lazaro, Jesús
  • Buyse, Bertien
  • Testelmans, Dries
  • Borzée, Pascal
  • Willems, Rik
  • Van Huffel, Sabine
  • Bailón, Raquel
  • Varon, Carolina
The high prevalence of sleep apnea syndrome (SAS) and its direct relationship with an augmented risk of cardiovascular disease (CVD) have raised SAS as a primary public health problem. For this reason, extensive research aiming to understand the interaction between both conditions has been conducted. The advances in non-invasive autonomic nervous system (ANS) monitoring through heart rate variability (HRV) analysis have revealed an increased sympathetic dominance in subjects suffering from SAS when compared with controls. Similarly, HRV analysis of subjects with CVD suggests altered autonomic activity. In this work, we investigated the altered autonomic control in subjects suffering from SAS and CVD simultaneously when compared with SAS patients, as well as the possibility that ANS assessment may be useful for the early stage identification of cardiovascular risk in subjects with SAS. The analysis was performed over 199 subjects from two independent datasets during night-time, and the effects of the physiological response following an apneic episode, sleep stages, and respiration on HRV were taken into account. Results, as measured by HRV, suggest a decreased sympathetic dominance in those subjects suffering from both conditions, as well as in subjects with SAS that will develop CVDs, which was reflected in a significantly reduced sympathovagal balance (p < 0.05). In this way, ANS monitoring could contribute to improve screening and diagnosis, and eventually aid in the phenotyping of patients, as an altered response might have direct implications on cardiovascular health.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Failure damage mechanical properties of thoracic and abdominal porcine aorta layers and related constitutive modeling: phenomenological and microstructural approach

  • Peña Baquedano, Juan Antonio
  • Martínez, Miguel A.
  • Peña, Estefanía
Despite increasing experimental and analytical efforts to investigate the irreversible effects of arterial tissue failure, the underlying mechanisms are still poorly understood. The goal of this study was to characterize the failure properties of the intact wall and each separated layer (intima, media, and adventitia) of the descending thoracic and infrarenal abdominal aorta and to test the hypothesis that the failure properties of layer-separated tissue depend on the location of the aorta. To test this hypothesis, we performed uniaxial tests to study the mechanical behavior of both intact and layer-separated porcine aortic tissue samples taken from descending thoracic and infrarenal abdominal aorta until complete failure. The fracture stress is higher in the infrarenal abdominal aorta than in the equivalent descending thoracic aorta. It was also found that the extrapolation of the elastic mechanical properties from the physiological to the supra-physiological regime for characterizing the mechanical response of the aorta would be inappropriate. Finally, we report values of constitutive parameters using phenomenological and microstructural damage models based on continuum damage mechanics theory. The phenomenological damage model gives an excellent fit to the experimental data compared to the microstructural damage model. Although the fitting results of the phenomenological model are better, the microstructural models can include physically motivated aspects obtained from experiments.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effect of haptic geometry in C-loop intraocular lenses on optical quality

  • Cabeza-Gil, I.
  • Pérez-Gracia, J.
  • Remón, L.
  • Calvo, B.
The biomechanical stability of intraocular lenses (IOLs) must achieve high-quality optical performance and clinical outcomes after cataract surgery. For this reason, the quality and performance features of the IOLs should be previously analysed following the Standard ISO 11979-2 and ISO 11979-3. The ISO 11979-3 tries to reproduce the behaviour of the IOL in the capsular bag by compressing the lens between two clamps. With this test, it has been demonstrated that the haptic design is a crucial factor to obtain biomechanical stability. Hence, the main goal of this study was to design an aberration-free aspheric IOL and to study the influence of haptic geometry on the optical quality. For that purpose, 5 hydrophobic IOLs with different haptic design were manufactured and their biomechanical stability was compared experimentally and numerically. The IOLs were classified as stiff and flexible designs depending on their haptic geometry. The biomechanical response was measured by means of the compression force, the axial displacement, the angle of contact or contact area, the decentration, the tilt and the strain energy. The results suggest that in vitro and in silico compression tests present similar responses for the IOLs analysed. Furthermore, the flexible IOL designs presented better biomechanical stability than stiff designs. These results were correlated with the optical performance, where the optical quality decreases with worst biomechanical stability. This numerical methodology provides an indisputable advance regarding IOL designs, leading to reduce costs by exploring a feasible space of solutions during the product design process and prior to manufacturing.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Crystal size dependence of dipolar ferromagnetic order between Mn6 molecular nanomagnets

  • Burzurí, E.
  • Martínez-Pérez, M. J.
  • Muntó, M.
  • Barrios, L. A.
  • Ventosa, N.
  • Roubeau, O.
  • Veciana, J.
  • Aromí, G.
  • Luis, F.
We study how crystal size influences magnetic ordering in arrays of molecular nanomagnets coupled by dipolar interactions. Compressed fluid techniques have been applied to synthesize crystals of Mn6 molecules (spin S = 12) with sizes ranging from 28 µm down to 220 nm. The onset of ferromagnetic order and the spin thermalization rates have been studied by means of ac susceptibility measurements. We find that the ordered phase remains ferromagnetic, as in the bulk, but the critical temperature Tc decreases with crystal size. Simple magnetostatic energy calculations, supported by Monte Carlo simulations, account for the observed drop in Tc in terms of the minimum attainable energy for finite-sized magnetic domains limited by the crystal boundaries. Frequency-dependent susceptibility measurements give access to the spin dynamics. Although magnetic relaxation remains dominated by individual spin flips, the onset of magnetic order leads to very long spin thermalization time scales. The results show that size influences the magnetism of dipolar systems with as many as 1011 spins and are relevant for the interpretation of quantum simulations performed on finite lattices.