Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A numerical investigation of changes in lens shape during accommodation

  • Cabeza-Gil, I.
  • Grasa, J.
  • Calvo, B.
The purpose of this study was to investigate how the mechanical properties and geometry of the lens influence the changes in lens shape during accommodation. To do so, ex vivo stretching tests of the isolated lens were simulated via finite element analysis. In these tests, the lens is stretched from the accommodated state to the non-accommodated state. Several key characteristics of the lens were studied: the stiffness gradient of the lens material, the distribution of the capsule thickness, the mechanical properties of the capsule and the material comprising the lens, nucleus and cortex, and the influence of two different age-related lens geometries (17 and 29 y/o subjects). To determine the effects on the changes in lens shape during accommodation, changes in the anterior and posterior radius, the lens and nucleus thicknesses and the equatorial lens diameter were analysed. The results suggest that multiple factors exert statistically significant influences on how the lens changes its shape, but two factors predominate over the rest: the stiffness ratio between the nucleus and cortex and the stiffness of the capsule, specifically the posterior surface.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mechanical characterisation of hydrophobic and hydrophilic acrylates used in intraocular lenses through depth sensing indentation

  • Cabeza-Gil, I.
  • Calvo, B.
  • Rico, A.
  • Reinhards-Hervás, C.
  • Rodríguez, J.
In this work, the mechanical behaviour of hydrophilic and hydrophobic acrylates has been characterised by depth sensing indentation. Time-dependent behaviour has been studied using load-relaxation tests. Experiments have been simulated with a finite element software using a visco-hyperelastic material model. The parameters of this model have been determined using deep learning techniques. The developed material models have been used to mechanically simulate a standard compression test of a prototype intraocular lens.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A detailed methodology to model the Non Contact Tonometry: a Fluid Structure Interaction study

  • Redaelli, Elena
  • Grasa, Jorge
  • Calvo, Begoña
  • Rodriguez Matas, Jose Felix
  • Luraghi, Giulia
Understanding the corneal mechanical properties has great importance in the study of corneal pathologies and the prediction of refractive surgery outcomes. Non-Contact Tonometry (NCT) is a non-invasive diagnostic tool intended to characterize the corneal tissue response in vivo by applying a defined air-pulse. The biomarkers inferred from this test can only be considered as indicators of the global biomechanical behaviour rather than the intrinsic biomechanical properties of the corneal tissue. A possibility to isolate the mechanical response of the corneal tissue is the use of an inverse finite element method, which is based on accurate and reliable modelling. Since a detailed methodology is still missing in the literature, this paper aims to construct a high-fidelity finite-element model of an idealized 3D eye for in silico NCT. A fluid-structure interaction (FSI) simulation is developed to virtually apply a defined air-pulse to a 3D idealized eye model comprising cornea, limbus, sclera, lens and humors. Then, a sensitivity analysis is performed to examine the influence of the intraocular pressure (IOP) and the structural material parameters on three biomarkers associated with corneal deformation. The analysis reveals the requirements for the in silico study linked to the correct reproduction of three main aspects: the air pressure over the cornea, the biomechanical properties of the tissues, and the IOP. The adoption of an FSI simulation is crucial to capture the correct air pressure profile over the cornea as a consequence of the air-jet. Regarding the parts of the eye, an anisotropic material should be used for the cornea. An important component is the sclera: the stiffer the sclera, the lower the corneal deformation due to the air-puff. Finally, the fluid-like behavior of the humors should be considered in order to account for the correct variation of the IOP during the test which will, otherwise, remain constant. The development of a strong FSI tool amenable to model coupled structures and fluids provides the basis to find the biomechanical properties of the corneal tissue in vivo.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Improving early detection of keratoconus by Non Contact Tonometry. A computational study and new biomarkers proposal

  • Redaelli, Elena
  • Nana, Michael
  • Calvo, Begoña
  • Rodríguez Matas, José Félix
  • Luraghi, Giulia
  • Rozema, Jos
  • Grasa, Jorge
Keratoconus is a progressive ocular disorder affecting the corneal tissue, leading to irregular astigmatism and decreased visual acuity. The architectural organization of corneal tissue is altered in keratoconus, however, data from ex vivo testing of biomechanical properties of keratoconic corneas are limited and it is unclear how their results relate to true mechanical properties in vivo. This study explores the mechanical properties of keratoconic corneas through numerical simulations of non-contact tonometry (NCT) reproducing the clinical test of the Corvis ST device. Three sensitivity analyses were conducted to assess the impact of corneal material properties, size, and location of the pathological area on NCT results. Additionally, novel asymmetry-based indices were proposed to better characterize corneal deformations and improve the diagnosis of keratoconus. Our results show that the weakening of corneal material properties leads to increased deformation amplitude and altered biomechanical response. Furthermore, asymmetry indices offer valuable information for locating the pathological tissue. These findings suggest that adjusting the Corvis ST operation, such as a camera rotation, could enhance keratoconus detection and provide insights into the relative position of the affected area. Future research could explore the application of these indices in detecting early-stage keratoconus and assessing the fellow eye's risk for developing the pathology
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modeling biological growth of human keratoconus: On the effect of tissue degradation, location and size

  • Fantaci, Benedetta
  • Calvo, Begoña
  • Rodríguez, José Félix
Keratoconus is a non-inflammatory bilateral disease, that usually occurs in the inferior-temporal region, where the cornea bulges out and becomes thinner, due to the gradual loss of structural organization in corneal tissue. Degenerated extracellular matrix and fibers breakage have been observed in keratoconic corneas, that may promote the progression of the pathology. While keratoconus histopathology has been widely described in literature, its etiology is still not clear. Being able to fully understand keratoconus growing process could be crucial to detect its development and improve prevention strategies. This work proposes a novel continuum-based keratoconus growth model. The proposed framework accounts for the structural changes occurring in the underlying tissue during the progression of the disease, as indicated in experiments. The developed formulation is able to replicate the typical bulging and thinning of keratoconic corneas, as well as different forms in terms of shape, as they are commonly classified in clinics (nipple, oval and globus cones). The cone that is obtained constitutes a permanent deformed state, not pressure dependent. The resulting model may help to better understand the etiology of the behavior of this disease with the aim of improving the diagnosis and the treatment of the pathology.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Non-contact tonometry: predicting intraocular pressure using a material—corneal thickness—independent methodology

  • Redaelli, Elena
  • Calvo, Begoña
  • Rodriguez Matas, Jose Felix
  • Luraghi, Giulia
  • Grasa, Jorge
Introduction: Glaucoma, a leading cause of blindness worldwide, is primarily caused by elevated intraocular pressure (IOP). Accurate and reliable IOP measurements are the key to diagnose the pathology in time and to provide for effective treatment strategies. The currently available methods for measuring IOP include contact and non contact tonometers (NCT), which estimate IOP based on the corneal deformation caused by an external load, that in the case of NCT is an air pulse. The deformation of the cornea during the tonometry is the result of the coupling between the IOP, the mechanical properties of the corneal tissue, the corneal thickness, and the external force applied. Therefore, there is the need to decouple the four contributions to estimate the IOP more reliably.Methods: This paper aims to propose a new methodology to estimate the IOP based on the analysis of the mechanical work performed by the air jet and by the IOP during the NCT test. A numerical eye model is presented, initially deformed by the action of a falling mass to study the energy balance. Subsequently, Fluid-Structure Interaction (FSI) simulations are conducted to simulate the action of Corvis ST.Results and discussion: The new IOP estimation procedure is proposed based on the results of the simulations. The methodology is centred on the analysis of the time of maximum apex velocity rather than the point of first applanation leading to a new IOP estimation not influenced by the geometrical and mechanical corneal factors.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Minimally Invasive Glaucoma Surgery Procedure in the Human Eye. A Fluid Structure Interaction Study

  • Redaelli, Elena
  • Perri, Letizia Maria
  • Calvo, Begoña
  • Grasa, Jorge
  • Luraghi, Giulia
Aqueous humor is a clear fluid pressurized at an intraocular pressure (IOP) within a range of 8–20 mmHg in healthy conditions that fills and shapes the anterior and posterior chambers of the eye. It is typically drained through the trabecular meshwork, but reduced permeability of this structure can lead to impaired drainage, elevated IOP, and the development of glaucoma. Minimally invasive glaucoma surgeries (MIGS) offer a treatment option by implanting micro stents to create alternative pathways for aqueous humor drainage. Despite their potential, limited research has explored the biomechanical changes in ocular tissues and the hydrodynamic interactions following MIGS implantation. This paper aims to study the aqueous humor flow after the surgery by means of computational simulations. For the first time, the implantation process has been simulated to assess residual stresses on ocular structures post‐implantation. Then, this study introduces a Fluid–Structure Interaction (FSI) simulation to model the aqueous humor dynamics after MIGS implantation. The results demonstrate the necessity of FSI simulations, as they reveal the interplay between the eye's biomechanical properties and the aqueous humor dynamics. The advantage of using an FSI simulation is its ability to capture the aqueous humor dynamics, providing a more realistic representation compared to the Computational Fluid Dynamic (CFD) simulations found in the literature. Using only CFD, the outflow velocity of the aqueous humor through the stent is approximately 1e−4 m/s, whereas with an FSI approach, the velocity reaches up to 0.8 m/s as the deformation of the ocular tissues has a substantial impact on the flow dynamics and cannot be neglected. This novel methodology can be potentially used for visualizing and quantifying the aqueous humor flow as a function of implant design, position and dimensions in order to design next‐generation MIGS devices and optimize implantation strategies, offering significant advancements in glaucoma treatment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Comparative evaluation of the mechanical properties of amniotic membranes for corneal grafting: Effects of cryopreservation, lyophilization, and dehydration

  • Fantaci, B.
  • Calvo, B.
  • Mesa, A.M.
  • Ortillés, A.
In both human and veterinary ophthalmology, stromal to full-thickness corneal defects can be treated using several techniques that involve various biomaterials, which support healing while preserving vision. Among these, the amniotic membrane stands out due to its multifaceted biological properties, including anti-inflammatory, antimicrobial, and regenerative capabilities. Three main preservation methods (cryopreservation, dehydration, and lyophilization) have been developed to facilitate amniotic membrane clinical use. However, these methods may significantly alter its mechanical and structural integrity, which are critical for graft success. This study investigates the mechanical performance of bovine amniotic membranes for veterinary use, preserved using the above-mentioned techniques, by means of uniaxial tensile and inflation tests in a non-biological in vitro setting. Structural and chemical differences are also analyzed using scanning electron microscopy and energy-dispersive X-ray spectroscopy. Despite structural differences arose among the samples, these differences did not alter or worsen the structural resistance of the membranes. All samples withstood 5 inflation cycles of 200 mmHg without leaking.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Biomechanically informed patient-specific in silico models for laser refractive surgery

  • Fantaci, Benedetta
  • Redaelli, Elena
  • Martí, Mònica
  • Julio, Gemma
  • Barraquer, Anton
  • Lamarca, Jose
  • Grasa, Jorge
  • Calvo, Begoña
Purpose: Corneal biomechanics plays a key role in the planning and outcomes of laser refractive surgery. This study presents a validated methodology for simulating patient-specific refractive treatments, focusing on the optomechanical effects of the three most commonly performed procedures: PRK, LASIK, and SMILE. Methods: For the first time, patient-specific mechanical properties of the cornea were incorporated into finite element simulations. These properties were estimated using an artificial neural network trained on in silico data from fluid–structure interaction models of non-contact tonometry. The tool takes as input corneal deformation images acquired with the Corvis ST device, intraocular pressure (IOP), and corneal geometry obtained from Pentacam imaging. IOP is estimated independently of corneal geometry and mechanical properties using a novel algorithm developed in prior studies. The methodology was tested on a cohort of 58 eyes from 29 patients who underwent one of the three procedures. Results: By integrating patient-specific geometry, IOP, and biomechanical characterization, the proposed framework successfully simulated postoperative corneal responses, yielding a mean dioptric error of +0.40 ± 0.30 D relative to clinical outcomes. Among the three procedures, SMILE produced the highest mechanical impact on the corneal model. Conclusion: This study introduces a personalized, biomechanically informed approach to simulate corneal behavior following refractive surgery. The proposed framework enhances surgical planning and improves prediction of postoperative refractive stability, offering a step toward personalized refractive correction and safer, more predictable clinical outcomes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Corneal deformation mapping and FE-based strain analysis via digital image correlation: Biomechanical changes after CXL and laser refractive surgery

  • Fantaci, Benedetta
  • Frechilla, Alejandro
  • Frigelli, Matteo
  • Büchler, Philippe
  • Kling, Sabine
  • Calvo, Begoña
Accurate assessment of corneal mechanical properties is critical for understanding ocular biomechanics, predicting refractive surgery outcomes, and optimizing cross-linking (CXL) treatments. Conventional uniaxial tensile testing is limited by non-physiological boundary conditions and simplified stress distributions. Inflation testing more closely reproduces the in vivo stress state but has traditionally lacked spatially distributed deformation mapping. In this work, we present an integrated experimental–computational protocol combining inflation testing of freshly enucleated porcine eyes with high-resolution three-dimensional digital image correlation (3D-DIC). Fifteen corneas were analyzed across three cohorts: (i) de-epithelialized controls, (ii) CXL-treated (standard Dresden protocol), and (iii) anterior stromal ablation via femtosecond laser. Samples were subjected to controlled intraocular pressure (IOP) elevations up to 40 mmHg. The 3D-DIC approach provided dense, pointwise displacement and strain maps across the anterior surface, successfully quantifying the localized stiffening effects of CXL and the increased compliance induced by stromal ablation. The surface kinematics was post-processed using a membrane-theory formulation to resolve principal in-plane strains, from which a regional strain metric was derived for inverse modeling with a fully three-dimensional finite element model to estimate anisotropic hyperelastic parameters of porcine corneal tissue. Overall, the method establishes an end-to-end route from physiologic loading to regional surface strain quantification and constitutive parameter identification, enabling quantitative evaluation of treatment-induced biomechanical changes in the cornea.