Pasar al contenido principal

ELECTRO-ELECTRODIALISIS APLICADA A LA INDUSTRIA DE PROCESAMIENTO DE MINERALES DE COBRE PARA LA RECUPERACION DE ANTIMONIO DE LAVADOS DE MINAS Y RECICLAJE DE LA DISOLUCION

PCI2019-103535

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos Programación Conjunta Internacional
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Increasing the sustainability of copper electrorefining: Selective electrodeposition of antimony in the presence of bismuth from highly concentrated hydrochloric acid effluents

  • Hernández-Pérez, Lorena
  • Muñoz-Perez, Alejandro
  • Ortega Navarro, Emma María|||0000-0001-6902-018X
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
  • Montañés, Maria-Teresa|||0000-0002-2620-6926
  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
[EN] Recovering critical materials from effluents of the copper electrorefining would improve the circularity and sustainability of this industry. In this task, selectivity is crucial to separate metals present in multi-component electrolytes and obtain added value products. Electrodeposition can be used to recover metals individually when their reduction takes place at different potentials. Moreover, the preferential deposition of a specific element can also be modulated under galvanostatic control. In this study, the recovery and separation of antimony and bismuth from highly concentrated hydrochloric acid solutions is investigated by means of voltammetry and electrodeposition. In potentiostatic mode, the preferential deposition of antimony takes place at -0.25 VAg/AgCl, although a moderate selectivity is achieved. Under galvanostatic mode, at current densities below the limiting value (i_L), the deposition of bismuth is almost prevented, and the selectivity factor for antimony reaches the highest values. These results prove the feasibility of a highly selective antimony recovery by electrodeposition. When the i_L is exceeded, the selectivity towards antimony drops because more cathodic potentials are reached, which activate the deposition of bismuth and hydrogen evolution, thus decreasing the overall electrodeposition current efficiency. Upon an increase in the proportion of bismuth in the mixtures, high current densities also favor the deposition of this metal but decrease the contribution of hydrogen evolution reaction as compared to solutions with a higher proportion of antimony. Thus, the process can also be conducted at high electrodeposition current densities, yet at the cost of obtaining the product in the form of an alloy., The authors thank the financial support from the Agencia Estatal de Investigacion (AEI/10.13039/501100011033) (Spain) under the project PCI2019-103535 and by FEDER A way of making Europe. Funding for open access charge: CRUE-Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effluents from the copper electrorefining as a secondary source of antimony: Role of mass transfer on the recovery by electrodeposition

  • Hernández-Pérez, Lorena
  • Carrillo-Abad, Jordi
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
  • Montañés, Maria-Teresa|||0000-0002-2620-6926
  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
[EN] The limited availability of antimony has increased the need for exploiting alternative sources to its direct extraction from stibnite deposits. Furthermore, introducing recovery techniques in industries where antimony is released in wastewaters leads to more responsible production routes. In this work, electrodeposition is employed to recover the antimony present in a secondary waste effluent of the copper electrorefining that is highly concentrated in hydrochloric acid. The electrochemical characterization of the system was conducted by voltammetry to identify a range of suitable operating conditions for the potentiostatic and galvanostatic electro-recovery of antimony. In potentiostatic mode, the progress of the secondary electrode reactions of hydrogen and chlorine evolution at potentials more cathodic than ¿0.38 V vs. Ag/AgCl causes the detachment and redissolution of the deposited antimony. Operating under galvanostatic control, similar effects were observed when the limiting current density is exceeded. Current efficiency and specific energy consumption values above 50 % and below 65 kW·h·kg¿1, were achieved below the limiting current density (1.265 mA·cm¿2). The operational range where electrodeposition of antimony is accelerated at increasing current densities can be broadened at intensified hydrodynamic conditions and higher concentrations of antimony. The detrimental effect of the hydrogen evolution reaction on the recovery of antimony decreases at high HCl concentrations., The authors thank the financial support from the Agencia Estatal de Investigacion (AEI/10.13039/501100011033) (Spain) under the project PCI2019-103535 and by FEDER A way of making Europe. Funding for open access charge: CRUE-Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Voltammetric and electrodeposition study for the recovery of antimony from effluents generated in the copper electrorefining process

  • Hernández-Pérez, Lorena
  • Carrillo-Abad, Jordi
  • Ortega Navarro, Emma María|||0000-0001-6902-018X
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
  • Montañés, Maria-Teresa|||0000-0002-2620-6926
  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
[EN] Antimony is a metalloid with limited availability as a primary resource, but it is commonly found as an impurity in effluents generated in the copper metallurgy. Thus, the development of clean and selective processes to recover antimony from these wastewaters would improve the sustainability of the copper production. In this work, an emulated effluent of the copper electrorefining industry that contains antimony and hydrochloric acid was characterized by means of voltammetric and electrodeposition tests using two different cell configurations: a static cell, and a dynamic cell with a rotating disk electrode (RDE). Voltammograms were obtained at varying hydrochloric acid and antimony concentrations, inversion potentials, scan rates and RDE rotation rates. Two main conclusions were drawn: (a) the deposition of antimony is a mass transfer-controlled process; and (b) an increase in hydrochloric acid concentration improves the deposition of antimony. The diffusion coefficient of antimony species was obtained applying the Randles-Šev¿ík and the Levich equations; both of them providing very similar values (5.29 ± 0.20 · 10¿6 cm2 s¿1). The effective electrodeposition of antimony from highly concentrated hydrochloric acid solutions was demonstrated. The surface examination of the electrodes revealed that compact and adherent deposits of antimony could be obtained under operating conditions that minimize the hydrogen evolution reaction in both potentiostatic and galvanostatic modes. Intensified convective regimes by using the RDE improve the supply of dissolved antimony towards the electrode surface, thus leading to a notorious increase in current density and, consequently, in the rate of antimony deposition., The authors thank the financial support from the Agencia Estatal de Investigacion (AEI/10.13039/501100011033) (Spain) under the project PCI2019-103535 and by FEDER A way of making Europe. Funding for open access charge: CRUE-Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Membrane electrolysis for recovering Sb and Bi from elution solutions of ion-exchange resins used in copper electrorefining: A cyclic voltammetric study

  • Santana-Barros, Kayo
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
  • Machado, André Luiz Vargas
  • Vielmo, Vicente Schaeffer
  • Velizarov, Svetlozar
  • Ferreira, Jane Zoppas
  • Bernardes, Andrea Moura
[EN] Antimony (Sb) and bismuth (Bi), which have been considered critical raw materials by the European Commission, cause inconveniences to copper production when they are present as impurities in copper elec-trorefining solutions. Therefore, ion-exchange resins to extract Sb and Bi from copper-containing electrolytes have typically been applied; after the adsorption of the metals, the elution step is conducted with an HCl solu-tion to desorb them. In the present study, a novel membrane electrolysis system with a cation-exchange mem-brane was proposed to extract Sb and Bi ions from the elution solution, and a cyclic voltammetric study was carried out to evaluate the influence of the most important operating parameters on the process performance, such as Sb, Bi and HCl concentration, dilution factor of the solution, the presence of thiourea as a complexing agent, the presence of iron as an impurity, and temperature. The obtained voltammograms indicated that the simultaneous presence of the metals in solution alters considerably their electrodeposition and oxidation pat-tern when compared to the solutions with pure metals. The reactions of electrodeposition of both metals are not electrochemically reversible and the diffusion control for bismuth is greater than that for antimony. The increase in the concentration of Sb affects its electrodeposition kinetically, whereas that of Bi is affected both kinetically and thermodynamically. The increase in HCl concentration disfavors the electrodeposition of both metals. Diluting the solution reduces the energy consumption and prolongs the membrane lifespan. Increasing the temperature reduces the cathodic potential to deposit the metals but favors the hydrogen evolution reac-tion. The presence of iron as an impurity does not affect the electrodeposition of both metals, whereas the use of thiourea as a complexing agent must be avoided because it impairs their electrodeposition., The authors gratefully acknowledge the financial support given by the funding agencies Ministerio de Universidades de Espana (European Union-Next Generation EU), CNPq (Process 160320/2019-4), Cyted (Network 318RT0551), ERAMIN2 (Network Sb-RECMEMTEC, FINEP-Brazil, ANID-Chile, and Agencia Estatal de Investigacion (AEI) - Spain), Direccin de Investigacion Cientifica y Tecnologica (DICYT) of the Universidad de Santiago de Chile, UFRGS (BIC-IQR838393LRG), Agencia Estatal de Investigacion (AEI) - Spain, through the project PCI2019-103535 (Co-funded by the European Regional Development Fund (FEDER), a way to build Europe). This study was financed in part by the Coordencao de Aperfeicoamento de Pessoal de Nivel Superior-Brasil (CAPES) - Finance Code 001 (Process 88887.364537/2019-00).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Recovery of hydrochloric acid and critical raw materials from an effluent of the copper electrorefining process using electromembrane reactors

  • Hernández-Pérez, Lorena
  • Tomaskova, B.
  • Montañés, Maria-Teresa|||0000-0002-2620-6926
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
[EN] Highly concentrated acids are used to regenerate ion-exchange resins that are applied for the removal of metallic impurities (i.e. antimony, arsenic and bismuth) from spent copper electrorefining baths, thus generating acidic effluents. In this work, the recovery of critical raw materials and HCl from a real effluent is evaluated by electrodeposition using reactors with and without membrane separators. First, four reduction peaks were detected by cyclic voltammetry, and their correspondence to the pairs Cu(II)/Cu(I), As(III)/As, Sb(III)/Sb, Bi(III)/Bi, and Cu (I)/Cu was confirmed by potentiostatic electrodeposition and elemental analysis of the deposits. A high selectivity towards antimony deposition over arsenic and copper was achieved at the least cathodic applied potential (¿ 0.25 VAg/AgCl), obtaining a deposit with 85 wt% of antimony and bismuth as the second most deposited metal. At more cathodic potentials, deposition of copper takes place and the antimony content in the deposits decreases. Galvanostatic electrodeposition tests were carried out using a three-compartment reactor. Results showed that the transport rate of Cl- ions through the anion-exchange membrane is too slow to recover highly concentrated HCl in a separate compartment. However, electrodeposition of the main elements present in the real effluent makes possible obtaining impurity-free HCl (4.8 M) in the cathodic compartment. The complete recovery of antimony (100 %) and almost complete recovery of bismuth (95 %) and copper (90 %) were achieved after 4 h working at ¿ 100 mA¿cm¿ 2. Tests conducted with a single-compartment reactor confirmed that formation of chlorine gas at the anode causes the redissolution of the metals deposited at the cathode, thus revealing that electromembrane reactors improve the electrodeposition current efficiency, The authors thank the financial support from the Agencia Estatal de Investigacion ¿ AEI/10.13039/501100011033) (Spain) under the project PCI2019 103535 and by FEDER A way of making Europe.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Interplay between Forced Convection and Electroconvection during the Overlimiting Ion Transport through Anion-Exchange Membranes: A Fourier Transform Analysis of Membrane Voltage Drops

  • Hernández-Pérez, Lorena
  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
  • Montañés, Maria-Teresa|||0000-0002-2620-6926
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
[EN] Electrodialysis (ED) applications have expanded in recent years and new modes of operation are being investigated. Operation at overlimiting currents involves the phenomenon of electroconvection, which is associated with the generation of vortices. These vortices accelerate the process of solution mixing, making it possible to increase the transport of ions across the membranes. In this work, frequency analysis is applied to investigate the interaction between different parameters on the development of electroconvection near anion-exchange membranes, which would provide a basis for the development of ED systems with favored electroconvection. Chronopotentiometric curves are registered and Fast Fourier Transform analysis is carried out to study the amplitude of the transmembrane voltage oscillations. Diverse behaviors are detected as a function of the level of forced convection and current density. The synergistic combination of forced convection and overlimiting currents leads to an increase in the signal amplitude, which is especially noticeable at frequencies around 0.1 Hz. Fast Fourier Transform analysis allows identifying, for a given system, the conditions that lead to a transition between stable and chaotic electroconvection modes., This research was funded by the Agencia Estatal de Investigacion (AEI/10.13039/501100011033) (Spain) under the project PCI2019-103535 and by FEDER A way of making Europe.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Tesis doctoral (DoctoralThesis)

Estudio electroquímico para la recuperación de antimonio de efluentes del electro-refinado de cobre por electrodeposición

  • Hernández Pérez, Lorena
[ES] Esta Tesis Doctoral se centra en la recuperación mediante electrodeposición del Sb presente en un efluente residual proveniente de la metalurgia del cobre. El efluente en el que se basa este estudio se produce en el proceso de regeneración con HCl concentrado de las resinas de intercambio iónico de una de las subetapas del electro-refinado del cobre. Se trata de un electrolito ácido que contiene diversas impurezas, entre las que destacan, Sb y Bi, que son considerados materias primas críticas por la Unión Europea, debido al riesgo de suministro que presentan y a su importancia en la economía. El objetivo de esta Tesis es la recuperación del Sb y la reutilización del HCl. Para alcanzar ambos propósitos se ha estudiado el empleo de la electrodeposición como operación de separación para el tratamiento del efluente. Este proceso se ha investigado mediante técnicas electroquímicas, en particular, voltametría cíclica y de barrido lineal. En primer lugar, se ha realizado el estudio con disoluciones sintéticas que emulan el efluente generado en las metalurgias chilenas. La caracterización electroquímica de la disolución de Sb en medio HCl ha evidenciado que la reducción del Sb(III) a Sb metálico está limitada por la transferencia de materia y que una concentración elevada de HCl favorece la recuperación del Sb. Los ensayos de electrodeposición han destacado la relevancia de las reacciones secundarias, la reacción de evolución del hidrógeno (HER) y la generación de cloro, y su influencia negativa sobre la deposición de Sb. La HER tiene lugar en el cátodo y conlleva la generación de burbujas de hidrógeno a elevadas densidades de corriente, que reducen la superficie útil del electrodo de trabajo e incluso causan el desprendimiento del depósito de Sb. Por su parte, la generación de cloro gas en el ánodo provoca la redisolución de los depósitos de Sb desprendidos a causa de la HER. Tras la realización de estos ensayos se ha concluido que se puede aumentar la tasa de recuperación de Sb si se tienen mayores concentraciones del elemento en la disolución o si se mejoran las condiciones hidrodinámicas. Se ha analizado también cómo influye la presencia de Bi en la disolución sintética durante la electrodeposición del Sb. El potencial de reducción de ambos elementos es similar, lo que implica que la recuperación individual de Sb sea compleja. No obstante, si se trabaja bajo condiciones en las que no se supere la densidad de corriente límite del sistema, se logra una elevada selectividad hacia el Sb. Si la concentración de Bi en la disolución es superior a la de Sb, se electrodepositan ambos elementos, pero se logra un elevado valor de eficiencia de corriente debido a que la influencia de la HER sobre el Bi no es tan fuerte. A continuación, se ha estudiado la aplicación de las técnicas previamente analizadas con un efluente real, facilitado por una empresa española. Se ha verificado que las conclusiones obtenidas con las disoluciones sintéticas son aplicables al efluente real. En particular, se ha confirmado que, al aumentar la densidad de corriente aplicada, la deposición de Sb se ve mermada debido a la relevancia del resto de reacciones: la reducción de los demás elementos y la evolución del medio. Los depósitos obtenidos contienen algunos de los elementos presentes en el efluente real: Sb, Bi, As y Cu, siendo mayoritario el primero. Como resultado, se ha concluido que es posible purificar el HCl mediante la electrodeposición de los elementos contenidos en el electrolito. Finalmente, se ha planteado la posibilidad de sustituir el HCl empleado como regenerante por un disolvente eutéctico profundo, debido a la alta solubilidad de metales y su procedencia de fuentes renovables. En particular, la investigación se ha llevado a cabo con la oxalina, la cual presenta una elevada capacidad de disolución para el Sb y una amplia ventana de potencial que beneficiaría la aplicación de la técnica de electrodeposición para la recuperación del Sb., [CA] Esta Tesi Doctoral se centra en la recuperació mitjançant electrodeposició del Sb present en un efluent residual provinent de la metal·lúrgia del coure. L'efluent en què es basa este estudi es produïx en el procés de regeneració amb HCl concentrat de les resines d'intercanvi iònic d'una de les subetapes de l'electro-refinat del coure. Es tracta d'un electròlit àcid que conté diverses impureses, entre les quals destaquen, Sb i Bi, que són considerats matèries primeres crítiques per la Unió Europea, a causa del risc de subministrament que presenten i a la seua importància en l'economia. L'objectiu d'esta Tesi és la recuperació del Sb i la reutilització de l'HCl. Per assolir aquests dos propòsits s'ha estudiat l'ús de l'electrodeposició com a operació de separació per al tractament de l'efluent. Este procés s'ha investigat mitjançant tècniques electroquímiques, en particular, voltametria cíclica i de rastreig lineal. En primer lloc, s'ha realitzat l'estudi amb dissolucions sintètiques que emulen l'efluent generat a les metal·lúrgies xilenes. La caracterització electroquímica de la dissolució de Sb en medi HCl ha evidenciat que la reducció del Sb(III) a Sb metàl·lic està limitada per la transferència de matèria i que una concentració elevada de HCl afavorix la recuperació del Sb. Els assajos d'electrodeposició han destacat la rellevància de les reaccions secundàries, la reacció d'evolució de l'hidrogen (HER) i la generació de clor, i la seua influència negativa sobre la deposició de Sb. La HER té lloc al càtode i comporta la generació de bambolles d'hidrogen a elevades densitats de corrent, la qual cosa reduïx la superfície útil de l'elèctrode de treball i fins i tot causa el despreniment del depòsit de Sb. Per la seua banda, la generació de clor gas a l'ànode provoca la redissolució dels depòsits de Sb despresos a causa de la HER. Després de la realització d'estos assajos s'ha conclòs que es pot augmentar la taxa de recuperació de Sb si es tenen majors concentracions de l'element en la dissolució o si es milloren les condicions hidrodinàmiques. S'ha analitzat també com influïx la presència de Bi en la dissolució sintètica durant l'electrodeposició del Sb. El potencial de reducció dels dos elements és similar, la qual cosa implica que la recuperació individual de Sb siga complexa. No obstant això, si es treballa sota condicions en què no se supere la densitat de corrent límit del sistema, s'aconseguix una elevada selectivitat cap al Sb. Si la concentració de Bi en la dissolució és superior a la de Sb, s'electrodepositen ambdós elements, però s'aconseguix un elevat valor d'eficiència de corrent pel fet que la influència de la HER sobre el Bi no és tan forta. A continuació, s'ha estudiat l'aplicació de les tècniques prèviament analitzades amb un efluent real, facilitat per una empresa espanyola. S'ha verificat que les conclusions obtingudes amb les dissolucions sintètiques són aplicables al efluent real. En particular, s'ha confirmat que, en augmentar la densitat de corrent aplicada, la deposició de Sb es veu minvada a causa de la rellevància de la resta de reaccions: la reducció dels altres elements i l'evolució del medi. Els depòsits obtinguts contenen alguns dels elements presents en el efluent real: Sb, Bi, As i Cu, sent majoritari el primer. Com a resultat, s'ha conclòs que és possible purificar l'HCl mitjançant l'electrodeposició dels elements continguts en l'electròlit. Finalment, s'ha plantejat la possibilitat de substituir l'HCl emprat com regenerant per un dissolvent eutèctic profund, a causa de l'alta solubilitat de metalls i la seua procedència de fonts renovables. En particular, la investigació s'ha dut a terme amb l'oxalina, la qual presenta una elevada capacitat de dissolució per al Sb i una àmplia finestra de potencial que beneficiaria l'aplicació de la tècnica d'electrodeposició per a la recuperació del Sb captat durant el procés de regeneració de les resines., [EN] This Doctoral Thesis focuses on the recovery by electrodeposition of Sb present in an effluent from the copper metallurgy. The effluent on which this study is based is generated during the regeneration with concentrated hydrochloric acid of the ion exchange resins used in one of the sub-stages of copper electro-refining. It is an acid electrolyte containing several impurities, among them, Sb and Bi, which are considered critical raw materials by the European Union due to their supply risk and economic relevance. The aim of this Thesis is the recovery of Sb and reuse of HCl. To achieve both objectives, electrodeposition has been studied as a separation operation for the treatment of the effluent. This operation has been investigated through electrochemical techniques, primarily, cyclic and linear sweep voltammetry. First, the study has been conducted with synthetic solutions emulating the effluent generated in the Chilean metallurgy industries. The electrochemical characterization of the Sb solution in the HCl medium has shown that, mass-transfer limits the reduction of Sb(III) to metallic Sb and a high HCl concentration favors the recovery of Sb. From the electrodeposition tests the relevance and negative influence on Sb deposition of the secondary reactions, the hydrogen evolution reaction (HER) and the chlorine generation, has been proven. The HER occurs at the cathode and involves the generation of hydrogen bubbles at high current densities, which decrease the effective surface area of the working electrode and even cause the detachment of the Sb deposits. The chlorine generation at the anode leads to the redissolution of the Sb deposits detached by the HER. After conducting these experiments, it has been concluded that it is possible to increase the Sb recovery rate, if higher concentrations of this element are present in the solution or the hydrodynamic conditions of the electrodeposition process are improved. The influence of the presence of Bi in the synthetic solution on the Sb electrodeposition has also been investigated. The reduction potential of both elements is similar, implying that the individual recovery of Sb by electrodeposition is challenging. However, if the operating conditions do not imply exceeding the limiting current density of the system, a high electrodeposition selectivity towards Sb is achieved. If the concentration of Bi in the solution is higher than that of Sb, the simultaneous electrodeposition of both elements takes place, but, on the contrary, a high value of current efficiency is obtained because the influence of the HER on Bi reduction is not as significant as that on Sb deposition. The application of the previously analyzed techniques has been studied with a real effluent, that was provided by a Spanish company. It has been proven that the conclusions obtained with the synthetic solutions can be applied to a real effluent. It has been confirmed that, as the applied current density increases, the Sb deposition worsens due to the relevance of the other reactions that take place during the process: the reduction of the other elements and the evolution of the medium. The deposits obtained contain some elements present in the real effluent: Sb, Bi, As and Cu, the most significant being the first. From this study, it has been concluded that purifying the HCl by removing the elements contained in the electrolyte via electrodeposition is possible. Finally, the possibility of replacing the HCl used as a regenerant with a deep eutectic solvent has been considered based on their properties, among which are a high solubility of metals and their synthesis from renewable sources. In particular, the research has been carried out with oxaline, which presents a high dissolution capacity for Sb and a wide potential window that would benefit the application of the electrodeposition technique to recover Sb captured during the resins regeneration process., Me gustaría agradecer la financiación a la Agencia Estatal de Investigación (AEI/10.13039/501100011033) (España) bajo el proyecto PCI2019-103535, gracias al cual he podido desarrollar la presente Tesis Doctoral, y a FEDER Una manera de hacer Europa