Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Long-term performance of magnetic force microscopy tips grown by focused electron beam induced deposition

  • Escalante-Quiceno, Alix Tatiana
  • Novotný, Ondřej
  • Neuman, Jan
  • Magén, César
  • Teresa, José María de
This article belongs to the Special Issue Advanced Sensing for Scanning Probe Microscopy., High-resolution micro- and nanostructures can be grown using Focused Electron Beam Induced Deposition (FEBID), a direct-write, resist-free nanolithography technology which allows additive patterning, typically with sub-100 nm lateral resolution, and down to 10 nm in optimal conditions. This technique has been used to grow magnetic tips for use in Magnetic Force Microscopy (MFM). Due to their high aspect ratio and good magnetic behavior, these FEBID magnetic tips provide several advantages over commercial magnetic tips when used for simultaneous topographical and magnetic measurements. Here, we report a study of the durability of these excellent candidates for high-resolution MFM measurements. A batch of FEBID-grown magnetic tips was subjected to a systematic analysis of MFM magnetic contrast for 30 weeks, using magnetic storage tape as a test specimen. Our results indicate that these FEBID magnetic tips operate effectively over a long period of time. The magnetic signal was well preserved, with a maximum reduction of 60% after 21 weeks of recurrent use. No significant contrast degradation was observed after 30 weeks in storage., This research received financial support from grant PDC2021-120852-C21 funded by MCIN/AEI/10.13039/501100011033, the European Union NextGenerationEU/PRTR, and Gobierno de Aragón through grant E13_20R., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Focused helium ion and electron beam-induced deposition of organometallic tips for dynamic atomic force microscopy of biomolecules in liquid

  • Allen, Frances I.
  • Teresa, José María de
  • Onoa, Bibiana
We demonstrate the fabrication of sharp nanopillars of high aspect ratio onto specialized atomic force microscopy (AFM) microcantilevers and their use for high-speed AFM of DNA and nucleoproteins in liquid. The fabrication technique uses localized charged-particle-induced deposition with either a focused beam of helium ions or electrons in a helium ion microscope (HIM) or scanning electron microscope (SEM). This approach enables customized growth onto delicate substrates with nanometer-scale placement precision and in situ imaging of the final tip structures using the HIM or SEM. Tip radii of <10 nm are obtained and the underlying microcantilever remains intact. Instead of the more commonly used organic precursors employed for bio-AFM applications, we use an organometallic precursor (tungsten hexacarbonyl) resulting in tungsten-containing tips. Transmission electron microscopy reveals a thin layer of carbon on the tips. The interaction of the new tips with biological specimens is therefore likely very similar to that of standard carbonaceous tips, with the added benefit of robustness. A further advantage of the organometallic tips is that compared to carbonaceous tips they better withstand UV–ozone cleaning treatments to remove residual organic contaminants between experiments, which are inevitable during the scanning of soft biomolecules in liquid. Our tips can also be grown onto the blunted tips of previously used cantilevers, thus providing a means to recycle specialized cantilevers and restore their performance to the original manufacturer specifications. Finally, a focused helium ion beam milling technique to reduce the tip radii and thus further improve lateral spatial resolution in the AFM scans is demonstrated., TEM characterization at the Molecular Foundry at Lawrence Berkeley National Laboratory was supported by the Office of Science, Office of Basic Energy Sciences, of the U.S. Department of Energy under Contract no. DE-AC02-05CH11231. B.O. acknowledges financial support from the Howard Hughes Medical Institute. J.M.D.T. acknowledges financial support from grants PID2020-112914RB-I00 and PDC2021-120852-C21 funded by MCIN/AEI/10.13039/501100011033 and the European Union NextGenerationEU/PRTR, and from grant E13_23R funded by Gobierno de Aragón., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Focused electron beam induced deposition of magnetic tips for improved magnetic force microscopy

  • Escalante-Quiceno, Alix Tatiana
  • Vega Fernández, Victoria
  • Martín, José Ignacio
  • Hierro-Rodríguez, Aurelio
  • Hlawacek, Gregor
  • Jaafar, Miriam
  • Asenjo Barahona, Agustina
  • Magén, César
  • Teresa, José María de
The combination of focused electron beam induced deposition (FEBID) and magnetic force microscopy (MFM) has opened up new possibilities in nanoscale magnetic imaging. FEBID offers precise control over the dimensions and magnetic properties of the MFM probes, enabling the development of high-performance magnetic tips with enhanced capabilities compared to conventional ones. These improved tips offer superior resolution, sensitivity, and versatility in nanoscale magnetic surface characterization. Here, we compare the performance of a commercial MFM tip and a FEBID-grown Fe tip in a Ni80Fe20/NdCo5 film. The FEBID tip exhibited superior lateral resolution for topography imaging, likely due to its sharper and well-defined geometry, with a tip diameter of approximately 20 nm. MFM measurements further confirmed this advantage, revealing better-defined magnetic domains and higher magnetic contrast with the FEBID-functionalized probes compared to the commercial tip. This improvement can be attributed to the possibility to optimize the tip-sample magnetic interaction for the FEBID tip. By reducing the lift height of the second pass, we were able to bring the tip closer to the sample, enhancing the magnetic signal without introducing significant topographic artifacts. Overall, these findings highlight the potential of FEBID for creating high-resolution and high-sensitivity MFM tips., This research received financial support from the grants PDC2021–120852-C21 and PID2023-146451OB-I00 funded by MCIN/AEI/10.13039/ 501100011033 and by the European Union NextGenerationEU/PRTR, and by Gobierno de Aragón through grant E13_23R. Authors acknowledge the use of the facilities as well as the technical advice provided by the National Facility ELECMI ICTS, node “Laboratorio de Microscopias Avanzadas (LMA)” at “Universidad de Zaragoza”. Financial support through a short-term scientific mission funded by the COST Action CA19140—Focused Ion Technology for Nanomaterials, supported by COST (European Cooperation in Science and Technology) is acknowledged https://www.fit4nano.eu/. V. V. F. acknowledges the support from the Severo Ochoa Predoctoral Fellowship Program (Nos. PA-22-BP21-124). This work has been supported by Spanish MCIN/AEI/10.13039/501100011033/FEDER,UE under grant PID2022-136784NB. M. J. and A. A. acknowledge the project TED2021-130957B-C55., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Long-term performance of magnetic force microscopy tips grown by focused electron beam induced deposition

  • Escalante-Quiceno, Alix Tatiana
  • Novotný, Ondrej
  • Neuman, Jan
  • Magén, César
  • De Teresa, José María
High-resolution micro- and nanostructures can be grown using Focused Electron Beam Induced Deposition (FEBID), a direct-write, resist-free nanolithography technology which allows additive patterning, typically with sub-100 nm lateral resolution, and down to 10 nm in optimal conditions. This technique has been used to grow magnetic tips for use in Magnetic Force Microscopy (MFM). Due to their high aspect ratio and good magnetic behavior, these FEBID magnetic tips provide several advantages over commercial magnetic tips when used for simultaneous topographical and magnetic measurements. Here, we report a study of the durability of these excellent candidates for high-resolution MFM measurements. A batch of FEBID-grown magnetic tips was subjected to a systematic analysis of MFM magnetic contrast for 30 weeks, using magnetic storage tape as a test specimen. Our results indicate that these FEBID magnetic tips operate effectively over a long period of time. The magnetic signal was well preserved, with a maximum reduction of 60% after 21 weeks of recurrent use. No significant contrast degradation was observed after 30 weeks in storage.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Focused Helium Ion and Electron Beam-Induced Deposition of Organometallic Tips for Dynamic Atomic Force Microscopy of Biomolecules in Liquid

  • Allen, Frances I.
  • De Teresa, José María
  • Onoa, Bibiana
We demonstrate the fabrication of sharp nanopillars of high aspect ratio onto specialized atomic force microscopy (AFM) microcantilevers and their use for high-speed AFM of DNA and nucleoproteins in liquid. The fabrication technique uses localized charged-particle-induced deposition with either a focused beam of helium ions or electrons in a helium ion microscope (HIM) or scanning electron microscope (SEM). This approach enables customized growth onto delicate substrates with nanometer-scale placement precision and in situ imaging of the final tip structures using the HIM or SEM. Tip radii of <10 nm are obtained and the underlying microcantilever remains intact. Instead of the more commonly used organic precursors employed for bio-AFM applications, we use an organometallic precursor (tungsten hexacarbonyl) resulting in tungsten-containing tips. Transmission electron microscopy reveals a thin layer of carbon on the tips. The interaction of the new tips with biological specimens is therefore likely very similar to that of standard carbonaceous tips, with the added benefit of robustness. A further advantage of the organometallic tips is that compared to carbonaceous tips they better withstand UV–ozone cleaning treatments to remove residual organic contaminants between experiments, which are inevitable during the scanning of soft biomolecules in liquid. Our tips can also be grown onto the blunted tips of previously used cantilevers, thus providing a means to recycle specialized cantilevers and restore their performance to the original manufacturer specifications. Finally, a focused helium ion beam milling technique to reduce the tip radii and thus further improve lateral spatial resolution in the AFM scans is demonstrated.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Substrate compatibility of Cryo-FIBID processes with the Co2(CO)8 precursor

  • Escalante-Quiceno, A. T.
  • Magén, C.
  • De Teresa, J. M.
Cryo-FIBID (focused ion beam induced deposition at cryogenic conditions) is an advanced nanofabrication technique that enables the controlled deposition of materials with high spatial resolution by condensing a precursor on a cooled substrate before ion beam irradiation. In this study, Cryo-FIBID using a Ga+ source and the Co2(CO)8 precursor was used to deposit cobalt layers on a variety of substrates, including metals, semiconductors, insulators, and graphene, without the need for conductive coatings on insulating surfaces. The microstructural and compositional properties of the deposits were probed by means of several microscopy techniques, which indicate that the deposits consist of homogeneous and compact cobalt-based thin layers. The investigation has revealed that two deposition parameters, the initial thickness of the condensed precursor layer and the Ga+ irradiation fluence, have a significant impact on the composition, microstructure and thickness of the final deposit. Interestingly, it was found that the cobalt content in the grown deposits depends strongly on the substrate material. Whereas deposits with a high cobalt content ( 60 at.%) are produced on Si, Au and Al substrates, the use of SiO2, graphene and SrTiO3 substrates gives rise to deposits with a lower cobalt content ( 40 at.%). The set of results highlights the versatility of Cryo-FIBID toward the growth of patterned cobalt-based structures on a wide range of substrates.