Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 43
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

UWB microwave functional brain activity extraction for Parkinson's disease monitoring

  • Akazzim, Youness|||0000-0002-7957-4044
  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • El Mrabet, Otman
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Microwaves have proven their imaging capabilities to visualize the body composition for medical applications, thanks to their penetration inside biological structures. In this context, this article presents a novel methodology that aims to extract not just the internal morphology, but also the brain’s functional activity using the UWB pulse amplitude modulation (PAM) technique to have simultaneously functional monitoring and imaging capability and apply it to monitor the Parkinson’s disease (PD). The radio-frequency system is composed of two orthogonal sets of double UWB probes operating in the frequency range of 0.5–1.5 GHz. An experimental setup has been devised that avoids complex in vivo testing, albeit allows a system proof-of-concept validation. A bio-tag (BT) consisting of an optically modulated photodiode is used to emulate local medium changes associated with cell activity. The proposed system is used to first extract the modeled brain action potential (AP) to validate the performance of the BT and then to monitor the PD based on the beta frequency band character within basal ganglia–thalamocortical (BGTC) which is a key marker for the PD. The results show a good capability of locating and differentiating the signals generated within the phantom by the BT, alternatively emulating the healthy and PD’s state, based on the frequency. The obtained results of the functional monitoring technique on distinguishing the healthy from nonhealthy brain model activity, as well as in the phantom mimicking the average proprieties of a human head, will serve as a basis for detecting functional diseases in the future., This work was supported in part by Comision Interministerial de Ciencia y Tecnologia (CICYT) PID2019-107885GB-C31, PID2022-136869NB-C31, Catalan Research Group 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR) under Grant 2021 FISDU 00195; in part by the PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya; and in part by the Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Split-ring resonator based microwave microfluidic biosensor for single bioparticle position location and live/dead cell differentiation

  • Ataa-Allah, Houda
  • Ataa Allah, Fatima
  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Aznabet, Mariem
  • El mrabet, Otman
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
© 2026 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This paper presents a novel microwave biosensor integrated with a microfluidic platform for the label-free detection and differentiation of biological particles, including live and dead Escherichia coli (E. coli). The sensor is based on a 50 O microstrip line coupled to an annular split-ring resonator (SRR), designed and fabricated for a high sensitivity response to changes in the dielectric properties on the bioparticle. The integration with a microfluidic channel allows precise control and delivery of biological samples to the sensing region. Experiments demonstrated the sensor’s ability to detect individual microbeads and distinguish between single live and dead bacterial cells through measurable shifts in resonance frequency. Furthermore, by applying an Inverse Fast Fourier Transform (IFFT) to the differential transmission parameter, the system enables the spatial localization of single particles within the microfluidic channel. The results indicate significant potential for point-of-care diagnostics and environmental monitoring applications, highlighting the advantages of microwave biosensing for real-time, single-particle analysis., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC 2021-007609, in part by the Agencia Estatal de Investigación, Spain under Grant CICYT PID2019107885GB-C31, Grant PID2022-136869NB-C31 funded byMICIU / AEI / 10.13039 / 501100011033/ FEDER, UE, and Grant Prueba de Concepto PDC 2022-133091-I00, in part by NextGeneration EU, in part by the CNRST as part of the “PhD-AssociateScholarship–PASS” Program.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Accurate and time-efficient electromagnetic scattering analysis of thick impenetrable planar structures

  • Úbeda Farré, Eduard|||0000-0001-6759-0445
  • Heldring, Alexander|||0000-0003-2011-2096
  • Tapia Folch, Núria
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
© 2025 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., The scattering analysis of perfectly conducting plates, with very small electrical thickness, in the free space is normally carried out through the zero-thickness approximation, which arises from modelling the whole closed surface enclosing the plate as an open surface. The resulting accuracy, though acceptable in many practical applications, deteriorates drastically for growing plate thicknesses or under grazing-angle incidence. In this paper, we provide a thorough description of the recently proposed thick-plate approach, which, while maintaining the agile single-mesh management of the zero-thickness scheme, offers improved accuracy with restricted computational overhead for a wider range of plate thicknesses or plane wave incidences. The computed thick-plate RCS solution deviation as compared with the zero-thickness and full method-of-moment solutions is quantified for an illustrative variety of flat perfectly conducting structures with different electrical dimensions, shapes (rectangular or circular), rim contour (straight or rounded) and plane wave incidence (perpendicular or grazing)., This work is part of the R&D projects PID2020-118410RB-C21, PID2023- 146245OB-C21, PID2022-136869NB-C31, PDC2022-133091-I00 funded by MICIU/AEI/10.13039/501100011033/FEDER/UE (Agencia Estatal de Investigación, Spain and the UE), and the Research Group 2021 SGR 01415 funded by the Catalan Agency for Management of University and Research Grants (AGAUR)., Peer Reviewed, 8 - Treball Decent i Creixement Econòmic, 8.2 - Aconseguir nivells més elevats de productivitat econòmica mitjançant la diversificació, la modernització tecnològica i la innovació, entre d’altres maneres centrant l’atenció en sectors de més valor afegit i ús intensiu de mà d’obra, 8.4 - Millorar progressivament, per a 2030, la producció i el consum eficients dels recursos mundials i procurar desvincular el creixement econòmic de la degradació del medi ambient, de conformitat amb el Marc decennal de programes sobre modalitats sostenibles de consum i producció, començant pels països desenvolupats, 9 - Indústria, Innovació i Infraestructura, 9.4 - Per a 2030, modernitzar les infraestructures i reconvertir les indústries perquè siguin sostenibles, usant els recursos amb més eficàcia i promovent l’adopció de tecnologies i processos industrials nets i racionals ambientalment, i aconseguint que tots els països adoptin mesures d’acord amb les capacitats respectives, 9.5 - Augmentar la investigació científica i millorar la capacitat tecnològica dels sectors industrials de tots els països, en particular els països en desenvolupament, entre d’altres maneres fomentant la innovació i augmentant substancialment, d’aquí al 2030, el nombre de persones que treballen en el camp de la investigació i el desenvolupament per cada milió d’habitants, així com la despesa en investigació i desenvolupament dels sectors públic i privat, 12.6 - Encoratjar les empreses, en especial les grans empreses i les empreses transnacionals, a adoptar pràctiques sostenibles i a incorporar informació sobre la sostenibilitat en el seu cicle de presentació d’informes, 12 - Producció i Consum Responsables
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Magnetoelectric dipole antenna framework supporting orbital angular momentum modes

  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Akazzim, Youness|||0000-0002-7957-4044
  • Blanch Boris, Sebastián|||0000-0002-8757-583X
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Cetiner, Bedri Artug
  • Jofre Roca, Lluís|||0000-0002-0547-901X
The ability to utilize resources to meet the need of growing diversity of communication services and user behavior marks the future of cognitive wireless communication systems. Cognitive wireless technologies for vehicular communications, in combination with Orbital Angular Momentum (OAM) modes aim at extending Non-Line-Of-Sight (NLOS) short-distance communications for smart mobility. In this regard, OAM antenna frameworks need to be developed to support these technologies. In this work, we describe a magnetoelectric dipole antenna framework supporting OAM modes. The framework is derived from moment tensors of specific vector spherical harmonic functions synthesized from dipoles. The antenna framework is discussed in terms of OAM generation, and it is validated numerically and experimentally for l = 1 OAM mode, achieving more than 500MHz operation bandwidth at the frequency of operation of 3.5GHz. Also, for l = 1 OAM mode, the null aligns precisely with the anticipated dimensions numerically computed., This work was financially supported by PDR-2014-2022/56-30157-2021-2A, 2021 SGR 01415 Q0818003F and Metropolis PLEC2021-007609 grants of the Generalitat de Catalunya and European Regional Development Fund (FEDER), by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31 and Prueba de Concepto PDC2022-133091-I00 grants of the Agencia Estatal de Investigación (Spain) and Next Generation EU., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Microwave contactless current-sensing for live/dead differentiation of single bioparticles on a microfluidic platform, Detección de corriente sin contacto de microondas para diferenciación en vivo/muerto de biopartículas individuales en una plataforma microfluidic

  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Jofre Cruanyes, Lluís|||0000-0003-2437-259X
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
© 2023 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., The combination of microwave and microfluidic technologies enables the creation of efficient platforms to rapidly quantify live/dead bioparticles in industrial processes, biomedical research and environmental monitoring applications. In this regard, this work demonstrates the differentiation of single live/dead bioparticles with a microwave-microfluidic platform. The system is composed of a contactless current-sensing superheterodyne architecture with broadband frequency-operation bowtie electrodes. Furthermore, the 20mm × 20mm bowtie electrode has been designed and manufactured with a –10 dB frequency range, from 4GHz to 8GHz, and capable of confining the electric field in a micrometric volume. The gap of the bowtie geometry of the electrodes is adjusted to the dimensions of the 50 µm × 50 µm cross-section and 40mm long microfluidic channel. In particular, 10mL sample with 10 9 bacteria/mL flows through the microchannel at 19.8 µL/min, focused with elasto-inertial effect enhanced with 500 ppm of polyethylene oxide. Accordingly, from the signal captured by the electrodes, the energy variation of the applied electric field produced by the bioparticles is sensed by a current-based transimpedance amplifier. Here, the incorporation of the transimpedance amplifier in the measurement system improves the SNR by 4 dB. In addition, the superheterodyne transceiver has been optimized in terms of local oscillator power and bandwidth. Furthermore, the microfluidic system has been adjusted so that the balance of hydrodynamic forces confines bioparticles at the centerline of the microchannel within less than 5 µm. As a result, the system measures the cytoplasmic content of live and dead flowing bacteria with a difference of 6 dB and relative deviation of 3.2%., This work was financially supported by the PID2019- 107885GB-C31 and PDC2022-133091-I00 grants of the Agencia Estatal de Investigación (Spain), and the PDR-2014- 2022/56-30157-2021-2A grant from Generalitat de Catalunya (Spain). In addition, the authors are grateful for the support provided by the Formación de Personal Investigador (PID2019-107885GB-C31, PRE2020-093895) scholarship and the Beatriz Galindo (BGP18/00026) program of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Microwave resonant wireless sensor for enhanced particle detection in microfluidic channels

  • Ataa-Allah, Houda
  • Ataa Allah, Fatima
  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Aznabet, Mariem
  • El mrabet, Otman
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
This paper presents a highly sensitive microwave sensor for bioparticle detection, designed around a ring-gap resonator integrated with a microfluidic channel. The sensor’s structure is optimized to enhance electric field confinement, improving its sensitivity to dielectric variations. Experimental validation using commercial microbeads as bioparticle models demonstrates clear resonance shifts, confirming the sensor’s capability for precise detection of particles up to 5 µm. These results highlight the potential of the proposed approach for realtime, label-free biosensing applications, offering a promising tool for biomedical diagnostics and analytical chemistry., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de Investigación, Spain, under Grant CICYT PID2019- 107885GBC31, Grant PID2022-136869NB-C31, and Grant Prueba de Concepto PDC2022-133091-I00; and in part by the Next Generation EU. Additionally, this work is supported by the CNRST as part of the ”PhD-Associate Scholarship – PASS” Program., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

OAM antennas for NLOS communications

  • Moriones Galve, Pau
  • Aldana Alonso, Rubén
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Molina García-Pardo, José María
  • Pascual García, Juan
  • Ferrando Bataller, Miguel
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
EM waves carrying orbital angular momentum (OAM) have been investigated in relation to their generation and transmission, with increasing interest in their usage and integration into modern communication systems. In the radio domain, the employment of a uniform circular array (UCA) featuring a consistent phase shift between neighboring elements is the most common technique employed in the literature to generate OAM carrying waves. Although offering an understandable solution, the consistent phase shift may not guarantee pure OAM generation and isolation between the different modes when interested on capacity increase with orthogonal multimodal solutions. In this work, the orientation of the elements in the antenna array is reviewed concerning collinear and radial arrangements of its elements, briefly analyzing the generation and transmission performance of different OAM eigenmodes, prioritizing short-range communication use cases. With respect to the latter, this report also addresses considerations about the performance evaluation of different OAM modes in the absence of clear LOS visibility under the aforementioned geometries., Grants PDR-2014-2022/56-30157-2021-2A, 2021 SGR 01415 Q0818003F, Metropolis PLEC2021-007609, PID2022-136869NB-C31, and PDC2022-133091-I00, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Improvements in randomized matrix compression methods for numerical analysis of antennas and scatterers

  • López Menchón, Héctor|||0000-0001-5776-1423
  • Heldring, Alexander|||0000-0003-2011-2096
  • Úbeda Farré, Eduard|||0000-0001-6759-0445
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
We propose a randomized Pseudo Skeleton (or CUR) Approximation method to compress the H-matrices of linear systems that arise in the discretization of integral equations in electromagnetic scattering. This method is highly parellelizable and well suited for fine-granularity architectures as GPUs. As the Adaptive Approximation Method (ACA), the method is purely algebraic. The method is tested with standard cases to assess its quality and efficiency, This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019-107885GBC31 / AEI / 10.13039/501100011033, PID2020-113832RBC21 / AEI / 10.13039/501100011033 and PID-2020-118410RB-C21 / AEI / 10.13039/501100011033, PDC2022-133091-I00 / AEI / 10.13039/501100011033, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Precision time protocol synchronization analysis for single and coincidence qubit detection in quantum networks

  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Saigi, Ferran
  • Rincón Rivera, David|||0000-0003-1294-3842
2025 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., The combination of Quantum and Telecommunications networks, offering unparalleled quantum correlation-based capabilities and making it an ideal choice for certain critical applications, requires precise time synchronization across network nodes. This work analytically and experimentally assessed the application of the IEEE 1588 Precision Time Protocol in achieving time synchronization within quantum networks. As results, operating at a repetition rate of 5MHz, the overall time synchronization precision is 65ns for single-qubit detection and 100ns for double-fold coincidence measurements. Correspondingly, the experimental results highlight the role of time-synchronization precision protocols in multi-node quantum networks and also provide insights for further developments for scalable quantum network infrastructure., This work was financially supported by PID2022-137329OB-C41 and PID2022-136869NB-C31 (MCIN / AEI / 10.13039 / 501100011033 / FEDER, UE), CNS2024-154600, PDC2022-133091-I00, grants of the Agencia Estatal de Investigaci´ on (Spain), Catalan Government University and Research Aid Management Agency (AGAUR) with Research Group grant 2021 SGR 01046, and ALECTORS 2024 grant from Universitat Polit` ecnica de Catalunya- BarcelonaTech (UPC).
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Microwave monitoring of Parkinson disease using a realistic human head model

  • Akazzim, Youness|||0000-0002-7957-4044
  • Gugliermino, Martina
  • Rodríguez Duarte, David Orlando
  • Tobón Vásquez, Jorge Alberto
  • Vipiana, Francesca
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Parkinson's disease (PD) is a widespread neurode-generative disorder characterized by the loss of dopaminergic neurons from the substantia nigra, causing bradykinesia, tremors, rigidity, and postural instability. In this paper, we present a differential microwave imaging study (MWI) for early-stage PD monitoring that uses the dielectric properties of the basal ganglia, particularly the thalamus. The simulations are carried out using two scenarios: one is based on studying the sensitivity of a realistic human head model. The other is the study of differential microwave imaging to monitor the PD based on the dopamine level changes in the basal ganglia. The MWI system contains 24 printed flexible antennas with a custom-made matching medium covering the head model. The obtained results demonstrate that small variations in dielectric properties within the human head, in particular the thalamus, can be detected, which can be used to monitor Parkinson's disease in a very early stage., This work was financially supported in part by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31, 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR)(2021 FISDU 00195), PDR-2014-2022/56-30157-2021-2 A grant of the Generalitat de Catalunya, and Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovacion y Universidades (Spain). This work was supported in part by the project PON Research and Innovation “Microwave Imaging and Detection powered by Artificial Intelligence for Medical and Industrial Applications (DM 1062/21)”, funded by MUR. It was carried out partially within the Agritech National Research Center, funded by the Next-Generation EU (PNRR, Missione 4, Componente 2, Investimento 1.4, D.D. 1032 17/06/2022, CN00000022., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Simple randomized strategies for low-rank matrix compression

  • López Menchón, Héctor|||0000-0001-5776-1423
  • Molina Burgués, Robert|||0009-0005-1314-3742
  • Heldring, Alexander|||0000-0003-2011-2096
  • Úbeda Farré, Eduard|||0000-0001-6759-0445
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
We propose a randomized Pseudo Skeleton (or CUR) approximation method to compress the H-matrices of linear systems that arise in the discretization of integral equations in electromagnetic scattering. This method is essentially the Matrix Decomposition Algorithm (MDA) of Michielssen and Boag (1994) with equivalent basis and testing functions equal to a random subset of the original ones. It is highly parellelizable and well suited for fine-granularity architectures as GPUs. As the Adaptive Cross Approximation (ACA), CUR is purely algebraic. The method is tested with standard cases to assess its quality and efficiency., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019-107885GBC31 / AEI / 10.13039/501100011033, PID2022-136869NBC31 / AEI / 10.13039/501100011033, PID2020-113832RBC21 / AEI / 10.13039/501100011033 and PID-2020-118410RB-C21 / AEI / 10.13039/501100011033, PDC2022-133091-I00 / AEI / 10.13039/501100011033, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Magnetòmetre de bombeig òptic amb guia magnètica d’elevada resolució espacial per a detectar gotes magnètiques en un canal microfluídic

  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Els sensors quàntics proporcionen una sensitivitat sense precedents per a detectar camps magnètics, fet que els permet ampliar l’abast habitual d’aplicacions i de contextos d’ús de la magnetometria. Moltes aplicacions també requereixen mesures magnètiques d’elevada resolució espacial en recerca biomèdica, monitoratge ambiental i producció industrial. En aquest aspecte, els magnetòmetres de bombeig òptic (OPM) són candidats destacats, però tenen limitacions a l’escala de les partícules magnètiques micromètriques, per exemple, gotes magnètiques. Per tractar aquesta limitació, aquí estudiem els efectes d’afegir una guia magnètica que fa de pont entre micròmetres i mil·límetres a un OPM en miniatura. Aquest instrument s’utilitza per a detectar gotes magnètiques de Fe3O4 a un flux de fins a 25 gotes per segon en un canal microfluídic. La resolució espacial calculada és de 300 µm i la relació senyal-soroll és més gran que 15 dB per a les diferents mides de gota magnètica estudiades., Aquest estudi ha estat finançat per l’ajuda DR-2014-2022/56-30157-2021-2A de la Generalitat de Catalunya i les ajudes ICYT PID2019-107885GB-C31 i Prueba de Concepto PDC2022-133091-I00 del Ministeri de Ciència, Innovació i Universitats (Espanya).
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Nonlinear microwave susceptibility measurements using intermodulation products on a microfluidic platform

  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • López Montero, María José|||0000-0002-2286-7479
  • Akazzim, Youness|||0000-0002-7957-4044
  • Jofre Cruanyes, Lluís|||0000-0003-2437-259X
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Measuring the nonlinear responses of living cells has enabled an understanding of their behavior and functionality. Currently, this response has been studied at radio and optical frequencies, leaving an unexplored gap in the field of microwaves. This paper presents a system that combines microwave technology with a microfluidic platform to measure the nonlinear susceptibility of living organisms to electromagnetic fields. The applied technique involves feeding the system with two tones (2.1 GHz and 4 GHz) to generate third-order intermodulation products (PIMP) at 5.9 GHz. Nonlinear susceptibility was measured from the power levels of PIMP using a spectrum analyzer. Broadband electrodes based on the slot bowtie geometry were manufactured to operate at 5 GHz with a bandwidth of 4 GHz. Additionally, an engineering process is presented to optimize the power of the internal mixer of the spectrum analyzer to obtain the maximum dynamic range and improve the sensitivity of the system. Nonlinear susceptibility to microwaves was analyzed in four samples: pure ethanol, a mixture of ethanol and dimethyl sulfoxide (DMSO), live Escherichia coli (E. coli), and heat-killed E. coli. The results show that ethanol has zero nonlinear susceptibility, whereas when it is mixed with DMSO, a nonlinear response appears at a value of 4 dB with respect to the nonlinear susceptibility of the system in the absence of a sample. Finally, the nonlinear susceptibility of live E. coli to microwaves was detected, with a difference of 8 dB over the reference value and 6 dB with respect to the heat-killed E. coli sample., This work was supported in part by the Agencia Estatal de Investigación, Spain, under Grant PID2019-107885GB-C31, Grant PID 2022-136869NB-C31, and Grant PDC2022-133091-I00; in part by the Generalitat de Catalunya, Spain, under Grant PDR-2014-2022/56-30157-2021-2A; in part by the ‘‘Formación de Personal Investigador’’ Scholarship under Grant PID2019-107885GB-C31 and Grant PRE2020-093895; and in part by the Beatriz Galindo Program of the Ministerio de Ciencia, Innovación y Universidades, Spain, under Grant BGP18/00026., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Qubit rate modulation-based time synchronization mechanism for multi-node quantum networks

  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
The combination of quantum and telecommunication networks enables to revolutionize the way information is used, offering unparalleled capabilities and making it an ideal choice for many critical applications. In this sense, quantum protocols generally have a unique requirement to have strict time synchronization in order to operate, which generally consume quantum resources of part of the exchanged qubits. Accordingly, work demonstrates and characterizes a temporal alignment mechanism for quantum networks based on frequency testing, allowing to preserve the quantum state of qubits. The time synchronization correction achieved is within 100 ns working at 5 MHz with temporal and relative frequency offsets commonly acquired in quantum links using conventional hardware clocks with temporal stability in the range of 10-8 and 200-ns jitter., This work was supported in part by the Agencia Estatal de Investigación (Spain) under Grant PID2022-137329OB-C41, Grant PID2022-136869NB-C31 (MCIN/AEI/10.13039/501100011033/FEDER, UE), Grant CNS2024-154600, and Grant PDC2022-133091-I00, in part by the Catalan Government University and Research Aid Management Agency (AGAUR) with Research Group under Grant 2021 SGR 01046, and in part by the Technical University of Catalonia (UPC) under Grant ALECTORS 2024.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Resonance-based microwave monitoring of live/dead bacteria in a microfluidic channel

  • Ataa-Allah, Houda
  • Aznabet, Mariem
  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Akazzim, Youness|||0000-0002-7957-4044
  • El mrabet, Otman
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
In this work, we have studied a highly sensitive microwave sensor for the detection of Escherichia coli (E. coli) bacteria at the single-cell level. The proposed system integrates a microwave sensor with a microfluidic channel for bacteria flow control. The microwave sensor is based on a planar microwave annular ring resonator working around 5GHz. Inside the channel, E. coli bacteria have been modeled using dielectric characteristics present in state-of-the-art literature. To enhance field confinement and achieve the highest electric field strength we have introduced two 50um gaps into the resonator. This approach holds great potential for different applications, including food safety control, healthcare diagnosis, and environmental monitoring, where the ability to detect a single E. coli cell is paramount., This work was financially supported in part by ID2019- 107885GBC31, PID2022-136869NB-C31, 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR) (2021 FISDU 00195), PDR-2014- 2022/56-30157-2021-2 Generalitat de Catalunya, and Prueba de Concepto PDC2022-133091-I00 Ministerio de Ciencia, Innovacion y Universidades (Spain)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Magnetoelectric dipole antenna extending NLOS short-distance vehicular communication with orbital angular momentum modes

  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Akazzim, Youness|||0000-0002-7957-4044
  • Towfiq, Asaduzzaman
  • Cetiner, Bedri Artug
  • Blanch Boris, Sebastián|||0000-0002-8757-583X
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
The ability to utilize resources to meet the need of growing diversity in services and user behavior marks the future of cognitive wireless communication systems. Cognitive wireless technologies for vehicular communications, in combination with Orbital Angular Momentum (OAM) modes aim at extending direct Non-Line-Of-Sight (NLOS) short-distance communications for smart mobility. In this regard, OAM antennas need to be developed to support these technologies. To this end, here we describe a compact antenna supporting the first OAM modes. Also, the antenna properties are discussed and are numerically and experimentally validated for OAM modes of l=±1 . Particularly, for the considered OAM modes, the antenna achieves more than 500 MHz operation bandwidth at the frequency of operation of 3.5 GHz. Also, for l=±1 OAM modes, the null beamwidth aligns precisely with the anticipated dimensions theoretically computed., This work was financially supported by PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya and by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31 and Prueba de Concepto PDC2022-133091-I00 and Metropolis PLEC2021-007609 grants of the Ministerio de Ciencia, Inno-vación y Universidades (Spain).
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Optically pumped magnetometer with high spatial resolution magnetic guide for the detection of magnetic droplets in a microfluidic channel

  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Quantum sensors provide unprecedented magnetic field detection sensitivities, enabling these to extend the common magnetometry range of applications and environments of operation. In this framework, many applications also require high spatial resolution magnetic measurements for biomedical research, environmental monitoring and industrial production. In this regard, optically pumped magnetometers (OPMs) are considered as prominent candidates, but are impaired in size with micrometer scale magnetic particles, e.g. magnetic droplets. In order to address this limitation, here we study the effects of adding a micrometer-to-millimeter magnetic guide to a miniature OPM. This device is applied to detect Fe3O4 magnetic droplets flowing at rates up to 25 drop.¿s-1 in a microfluidic channel. The computed spatial resolution is 300¿µm and the measured signal-to-noise ratio is larger than 15¿dB for the different sizes of considered magnetic droplets., This work was financially supported by PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya and by CICYT PID2019-107885GB-C31 and Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Microwave imaging for Parkinson’s disease detection: A phantom-based feasibility study using temperature-controlled dielectric variations

  • Cardinali, Leonardo
  • Rodríguez Duarte, David Orlando
  • Tobón Vásquez, Jorge Alberto
  • Vipiana, Francesca
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Parkinson’s disease (PD) is characterized by pathological changes in the substantia nigra, which in its early stages may manifest as structural and functional asymmetries between the two hemispheres. Microwave imaging has recently emerged as a promising non-invasive tool to detect subtle dielectric variations. In the context of Parkinson’s disease, such contrasts are expected to arise from the underlying physiological alterations in brain tissue, although their magnitude has not yet been fully characterized. In this work, we investigate the feasibility of differential microwave imaging, where detection is based on permittivity contrasts, through a controlled phantom study. A simple two-dimensional head phantom was constructed using a 3D-printed cylindrical container filled with water, incorporating a Teflon tube to represent the substantia nigra. The tube was filled with hot water, whose gradual cooling emulated small dielectric changes. Since the dielectric properties of water vary linearly with temperature over 0.5–3 GHz, we first validated this dependence through both numerical analysis and experimental measurements. Four antennas were then employed in a differential imaging configuration, with image reconstruction performed via the multi-frequency bi-focusing algorithm. The results show that the system can successfully detect a dielectric contrast corresponding to a temperature variation as small as 0.4 °C, equivalent to approximately 0.17% in relative permittivity. While the exact dielectric changes associated with PD remain to be determined, these results demonstrate that the proposed approach is sensitive to very small contrasts, supporting the potential of differential microwave imaging as a candidate tool for future investigations into Parkinson’s disease detection., This work was supported in part by the project “THERAD—Microwave Theranostics for Alzheimer’s Disease”, funded by Compagnia di San Paolo; in part by the project “INSIGHTFOOD—An innovative microwave sensing system for the evaluation and monitoring of food quality and safety”, funded by the Italian Ministry of Foreign Affairs and International Cooperation (MAECI, CUP E13C23000180005); in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de lnvestigacion, Spain, under Grant CICYT PID2019-107885GBC31, Grant PID2022-136869NB-C31, and Grant Prueba de Concepto PDC2022-133091-IO0; and in part by Next Generation EU. It was carried out partially within the Agritech National Research Center, funded by the European Union Next—Generation EU (Piano Nazionale di Ripresa e Resilienza (PNRR)—MISSIONE 4 COMPONENTE 2, INVESTIMENTO 1.4—D.D. 1032 17/06/2022, CN00000022)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

High-sensitivity microwave resonator sensor for aqueous glucose detection using field-concentrating elements

  • Ataa Allah, Fatima
  • Ataa-Allah, Houda
  • El mrabet, Otman
  • Aznabet, Mariem
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
In this article, we present a highly sensitive microwave sensor for determining the concentration of aqueous glucose solutions in the microwave regime. The proposed sensor is based on a single split-ring resonator (SRR) printed on a Rogers RO3003 substrate and operates at 2.9 GHz. The sensitivity of this sensor is enhanced by using a narrow gap of approximately 100 µm, which increases the capacitance of the SRR and, more importantly, produces a localized field enhancement within the gap region. Moreover, the proposed design operates with only 2 µL of sample, a notable improvement over sensors that typically require larger liquid volumes. Both the simulation and measurement results showed a clear linear shift in the resonance frequency over a concentration range of 0–400 mg/dL, with the ability to detect minimal concentration variations as small as 50 mg/dL. These results confirm the effectiveness of the sensor for noninvasive glucose detection and represent a significant advancement in the field of microwave sensing., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de Investigación, Spain, under Grant CICYT PID2019-107885GB- C31, PID2022-136869NB-C31 MICIU / AEI / 10.13039 / 501100011033/ FEDER, UE, and Grant Prueba de Concepto PDC2022-133091-I00; and in part by the Next Generation EU. Additionally, this work is supported by the CNRST as part of the ”PhD-Associate Scholarship– PASS” Program., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Fast direct high frequency MoM solver using Butterfly algebra

  • Heldring, Alexander|||0000-0003-2011-2096
  • Úbeda Farré, Eduard|||0000-0001-6759-0445
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
Butterfly decomposition is a powerful method for compressing the Method of Moments impedance matrix at arbitrarily high frequency. It has been used to accelerate iterative solvers, achieving N log2 N, or “pseudo-linear” complexity per iteration. For direct solvers, pseudo-linear complexity has remained elusive. Presently, the lowest complexity achieved for high frequency impedance matrix factorization appears to be N3/2 logN, with an algorithm based on Butterfly decomposition. Further improvement requires an efficient Butterfly algebra, itself of pseudo-linear complexity. This paper introduces such an algebra, including summation, multiplication, concatenation and splitting of Butterfly decompositions. It is applied to matrix factorization, which is demonstrated both theoretically and through numerical examples to yield N log4 N complexity., This work is part of the R&D projects PID2023-146245OB-C21, PID2022-136869NB-C31 and PDC2022-133091-I00 funded by MICIU/AEI/10.13039/501100011033/FEDER/UE (Agencia Estatal de Investigación, Spain and the EU), and the Research Group 2021 SGR 01415 funded by the Catalan Agency for Management of University and Research Grants (AGAUR)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Time-domain modeling of nonlinear microwave electroporation in biological cells

  • Vico Bondia, Felipe
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Jofre Roca, Lluís|||0000-0002-0547-901X
  • Ferrando Bataller, Miguel
We present a numerical framework to simulate the nonlinear electromagnetic response of biological cells subjected to microwave excitation. Building on recent experimental studies that detect third-order intermodulation products from living cells, our model captures the electrodynamic behavior of membranes via time-dependent conductivity and permittivity changes associated with electroporation. The governing equations are formulated in the time domain, based on a fullwave Maxwell model for TE polarization, and discretized using a semi-implicit scheme coupled with a high-order fast direct solver. Validation against reference solutions in both damped and lossless configurations demonstrates high accuracy and numerical stability. We further illustrate the nonlinear current response of a single cell placed between parallel electrodes under time-varying voltage stimulation. The results highlight the potential of this computational approach to predict nonlinear microwave interactions in cellular environments and to complement experimental microfluidic platforms for future sensing and biomedical applications., This work was supported by the Ministerio de Ciencia e Innovación under research project PID2022-136869NB-C33 and PDC2022-133091-I00 grants of the Agencia Estatal de Investigación (Spain). This study was also supported by the Generalitat Valenciana through project MAOCOM-6G (Code: MFA/2022/056)., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Improvements in randomized matrix compression methods for numerical analysis of antennas and scatterers

  • López Menchón, Héctor
  • Heldring, Alexander
  • Úbeda Farré, Eduard
  • Rius Casals, Juan Manuel
We propose a randomized Pseudo Skeleton (or CUR) Approximation method to compress the H-matrices of linear systems that arise in the discretization of integral equations in electromagnetic scattering. This method is highly parellelizable and well suited for fine-granularity architectures as GPUs. As the Adaptive Approximation Method (ACA), the method is purely algebraic. The method is tested with standard cases to assess its quality and efficiency, This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019-107885GBC31 / AEI / 10.13039/501100011033, PID2020-113832RBC21 / AEI / 10.13039/501100011033 and PID-2020-118410RB-C21 / AEI / 10.13039/501100011033, PDC2022-133091-I00 / AEI / 10.13039/501100011033, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Time-domain modeling of nonlinear microwave electroporation in biological cells

  • Vico Bondia, Felipe
  • Romeu Robert, Jordi
  • Jofre Cruanyes, Marc
  • Jofre Roca, Lluís
  • Ferrando Bataller, Miguel
We present a numerical framework to simulate the nonlinear electromagnetic response of biological cells subjected to microwave excitation. Building on recent experimental studies that detect third-order intermodulation products from living cells, our model captures the electrodynamic behavior of membranes via time-dependent conductivity and permittivity changes associated with electroporation. The governing equations are formulated in the time domain, based on a fullwave Maxwell model for TE polarization, and discretized using a semi-implicit scheme coupled with a high-order fast direct solver. Validation against reference solutions in both damped and lossless configurations demonstrates high accuracy and numerical stability. We further illustrate the nonlinear current response of a single cell placed between parallel electrodes under time-varying voltage stimulation. The results highlight the potential of this computational approach to predict nonlinear microwave interactions in cellular environments and to complement experimental microfluidic platforms for future sensing and biomedical applications., This work was supported by the Ministerio de Ciencia e Innovación under research project PID2022-136869NB-C33 and PDC2022-133091-I00 grants of the Agencia Estatal de Investigación (Spain). This study was also supported by the Generalitat Valenciana through project MAOCOM-6G (Code: MFA/2022/056)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

High-sensitivity microwave resonator sensor for aqueous glucose detection using field-concentrating elements

  • Ataa Allah, Fatima
  • Ataa-Allah, Houda
  • El mrabet, Otman
  • Aznabet, Mariem
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
In this article, we present a highly sensitive microwave sensor for determining the concentration of aqueous glucose solutions in the microwave regime. The proposed sensor is based on a single split-ring resonator (SRR) printed on a Rogers RO3003 substrate and operates at 2.9 GHz. The sensitivity of this sensor is enhanced by using a narrow gap of approximately 100 µm, which increases the capacitance of the SRR and, more importantly, produces a localized field enhancement within the gap region. Moreover, the proposed design operates with only 2 µL of sample, a notable improvement over sensors that typically require larger liquid volumes. Both the simulation and measurement results showed a clear linear shift in the resonance frequency over a concentration range of 0–400 mg/dL, with the ability to detect minimal concentration variations as small as 50 mg/dL. These results confirm the effectiveness of the sensor for noninvasive glucose detection and represent a significant advancement in the field of microwave sensing., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de Investigación, Spain, under Grant CICYT PID2019-107885GB- C31, PID2022-136869NB-C31 MICIU / AEI / 10.13039 / 501100011033/ FEDER, UE, and Grant Prueba de Concepto PDC2022-133091-I00; and in part by the Next Generation EU. Additionally, this work is supported by the CNRST as part of the ”PhD-Associate Scholarship– PASS” Program., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Magnetòmetre de bombeig òptic amb guia magnètica d’elevada resolució espacial per a detectar gotes magnètiques en un canal microfluídic

  • Jofre Cruanyes, Marc
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Els sensors quàntics proporcionen una sensitivitat sense precedents per a detectar camps magnètics, fet que els permet ampliar l’abast habitual d’aplicacions i de contextos d’ús de la magnetometria. Moltes aplicacions també requereixen mesures magnètiques d’elevada resolució espacial en recerca biomèdica, monitoratge ambiental i producció industrial. En aquest aspecte, els magnetòmetres de bombeig òptic (OPM) són candidats destacats, però tenen limitacions a l’escala de les partícules magnètiques micromètriques, per exemple, gotes magnètiques. Per tractar aquesta limitació, aquí estudiem els efectes d’afegir una guia magnètica que fa de pont entre micròmetres i mil·límetres a un OPM en miniatura. Aquest instrument s’utilitza per a detectar gotes magnètiques de Fe3O4 a un flux de fins a 25 gotes per segon en un canal microfluídic. La resolució espacial calculada és de 300 µm i la relació senyal-soroll és més gran que 15 dB per a les diferents mides de gota magnètica estudiades., Aquest estudi ha estat finançat per l’ajuda DR-2014-2022/56-30157-2021-2A de la Generalitat de Catalunya i les ajudes ICYT PID2019-107885GB-C31 i Prueba de Concepto PDC2022-133091-I00 del Ministeri de Ciència, Innovació i Universitats (Espanya)., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

UWB microwave functional brain activity extraction for Parkinson's disease monitoring

  • Akazzim, Youness
  • Palacios Arias, César Augusto
  • Jofre Cruanyes, Marc
  • El Mrabet, Otman
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Microwaves have proven their imaging capabilities to visualize the body composition for medical applications, thanks to their penetration inside biological structures. In this context, this article presents a novel methodology that aims to extract not just the internal morphology, but also the brain’s functional activity using the UWB pulse amplitude modulation (PAM) technique to have simultaneously functional monitoring and imaging capability and apply it to monitor the Parkinson’s disease (PD). The radio-frequency system is composed of two orthogonal sets of double UWB probes operating in the frequency range of 0.5–1.5 GHz. An experimental setup has been devised that avoids complex in vivo testing, albeit allows a system proof-of-concept validation. A bio-tag (BT) consisting of an optically modulated photodiode is used to emulate local medium changes associated with cell activity. The proposed system is used to first extract the modeled brain action potential (AP) to validate the performance of the BT and then to monitor the PD based on the beta frequency band character within basal ganglia–thalamocortical (BGTC) which is a key marker for the PD. The results show a good capability of locating and differentiating the signals generated within the phantom by the BT, alternatively emulating the healthy and PD’s state, based on the frequency. The obtained results of the functional monitoring technique on distinguishing the healthy from nonhealthy brain model activity, as well as in the phantom mimicking the average proprieties of a human head, will serve as a basis for detecting functional diseases in the future., This work was supported in part by Comision Interministerial de Ciencia y Tecnologia (CICYT) PID2019-107885GB-C31, PID2022-136869NB-C31, Catalan Research Group 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR) under Grant 2021 FISDU 00195; in part by the PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya; and in part by the Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Simple randomized strategies for low-rank matrix compression

  • López Menchón, Héctor
  • Molina Burgués, Robert
  • Heldring, Alexander
  • Úbeda Farré, Eduard
  • Rius Casals, Juan Manuel
We propose a randomized Pseudo Skeleton (or CUR) approximation method to compress the H-matrices of linear systems that arise in the discretization of integral equations in electromagnetic scattering. This method is essentially the Matrix Decomposition Algorithm (MDA) of Michielssen and Boag (1994) with equivalent basis and testing functions equal to a random subset of the original ones. It is highly parellelizable and well suited for fine-granularity architectures as GPUs. As the Adaptive Cross Approximation (ACA), CUR is purely algebraic. The method is tested with standard cases to assess its quality and efficiency., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019-107885GBC31 / AEI / 10.13039/501100011033, PID2022-136869NBC31 / AEI / 10.13039/501100011033, PID2020-113832RBC21 / AEI / 10.13039/501100011033 and PID-2020-118410RB-C21 / AEI / 10.13039/501100011033, PDC2022-133091-I00 / AEI / 10.13039/501100011033, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Fast direct high frequency MoM solver using Butterfly algebra

  • Heldring, Alexander
  • Úbeda Farré, Eduard
  • Rius Casals, Juan Manuel
Butterfly decomposition is a powerful method for compressing the Method of Moments impedance matrix at arbitrarily high frequency. It has been used to accelerate iterative solvers, achieving N log2 N, or “pseudo-linear” complexity per iteration. For direct solvers, pseudo-linear complexity has remained elusive. Presently, the lowest complexity achieved for high frequency impedance matrix factorization appears to be N3/2 logN, with an algorithm based on Butterfly decomposition. Further improvement requires an efficient Butterfly algebra, itself of pseudo-linear complexity. This paper introduces such an algebra, including summation, multiplication, concatenation and splitting of Butterfly decompositions. It is applied to matrix factorization, which is demonstrated both theoretically and through numerical examples to yield N log4 N complexity., This work is part of the R&D projects PID2023-146245OB-C21, PID2022-136869NB-C31 and PDC2022-133091-I00 funded by MICIU/AEI/10.13039/501100011033/FEDER/UE (Agencia Estatal de Investigación, Spain and the EU), and the Research Group 2021 SGR 01415 funded by the Catalan Agency for Management of University and Research Grants (AGAUR)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Magnetoelectric dipole antenna framework supporting orbital angular momentum modes

  • Jofre Cruanyes, Marc
  • Akazzim, Youness
  • Blanch Boris, Sebastián
  • Romeu Robert, Jordi
  • Cetiner, Bedri Artug
  • Jofre Roca, Lluís
The ability to utilize resources to meet the need of growing diversity of communication services and user behavior marks the future of cognitive wireless communication systems. Cognitive wireless technologies for vehicular communications, in combination with Orbital Angular Momentum (OAM) modes aim at extending Non-Line-Of-Sight (NLOS) short-distance communications for smart mobility. In this regard, OAM antenna frameworks need to be developed to support these technologies. In this work, we describe a magnetoelectric dipole antenna framework supporting OAM modes. The framework is derived from moment tensors of specific vector spherical harmonic functions synthesized from dipoles. The antenna framework is discussed in terms of OAM generation, and it is validated numerically and experimentally for l = 1 OAM mode, achieving more than 500MHz operation bandwidth at the frequency of operation of 3.5GHz. Also, for l = 1 OAM mode, the null aligns precisely with the anticipated dimensions numerically computed., This work was financially supported by PDR-2014-2022/56-30157-2021-2A, 2021 SGR 01415 Q0818003F and Metropolis PLEC2021-007609 grants of the Generalitat de Catalunya and European Regional Development Fund (FEDER), by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31 and Prueba de Concepto PDC2022-133091-I00 grants of the Agencia Estatal de Investigación (Spain) and Next Generation EU., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Microwave monitoring of Parkinson disease using a realistic human head model

  • Akazzim, Youness
  • Gugliermino, Martina
  • Rodríguez Duarte, David Orlando
  • Tobón Vásquez, Jorge Alberto
  • Vipiana, Francesca
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Parkinson's disease (PD) is a widespread neurode-generative disorder characterized by the loss of dopaminergic neurons from the substantia nigra, causing bradykinesia, tremors, rigidity, and postural instability. In this paper, we present a differential microwave imaging study (MWI) for early-stage PD monitoring that uses the dielectric properties of the basal ganglia, particularly the thalamus. The simulations are carried out using two scenarios: one is based on studying the sensitivity of a realistic human head model. The other is the study of differential microwave imaging to monitor the PD based on the dopamine level changes in the basal ganglia. The MWI system contains 24 printed flexible antennas with a custom-made matching medium covering the head model. The obtained results demonstrate that small variations in dielectric properties within the human head, in particular the thalamus, can be detected, which can be used to monitor Parkinson's disease in a very early stage., This work was financially supported in part by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31, 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR)(2021 FISDU 00195), PDR-2014-2022/56-30157-2021-2 A grant of the Generalitat de Catalunya, and Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovacion y Universidades (Spain). This work was supported in part by the project PON Research and Innovation “Microwave Imaging and Detection powered by Artificial Intelligence for Medical and Industrial Applications (DM 1062/21)”, funded by MUR. It was carried out partially within the Agritech National Research Center, funded by the Next-Generation EU (PNRR, Missione 4, Componente 2, Investimento 1.4, D.D. 1032 17/06/2022, CN00000022., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Magnetoelectric dipole antenna extending NLOS short-distance vehicular communication with orbital angular momentum modes

  • Jofre Cruanyes, Marc
  • Akazzim, Youness
  • Towfiq, Asaduzzaman
  • Cetiner, Bedri Artug
  • Blanch Boris, Sebastián
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
The ability to utilize resources to meet the need of growing diversity in services and user behavior marks the future of cognitive wireless communication systems. Cognitive wireless technologies for vehicular communications, in combination with Orbital Angular Momentum (OAM) modes aim at extending direct Non-Line-Of-Sight (NLOS) short-distance communications for smart mobility. In this regard, OAM antennas need to be developed to support these technologies. To this end, here we describe a compact antenna supporting the first OAM modes. Also, the antenna properties are discussed and are numerically and experimentally validated for OAM modes of l=±1 . Particularly, for the considered OAM modes, the antenna achieves more than 500 MHz operation bandwidth at the frequency of operation of 3.5 GHz. Also, for l=±1 OAM modes, the null beamwidth aligns precisely with the anticipated dimensions theoretically computed., This work was financially supported by PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya and by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31 and Prueba de Concepto PDC2022-133091-I00 and Metropolis PLEC2021-007609 grants of the Ministerio de Ciencia, Inno-vación y Universidades (Spain)., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Optically pumped magnetometer with high spatial resolution magnetic guide for the detection of magnetic droplets in a microfluidic channel

  • Jofre Cruanyes, Marc
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Quantum sensors provide unprecedented magnetic field detection sensitivities, enabling these to extend the common magnetometry range of applications and environments of operation. In this framework, many applications also require high spatial resolution magnetic measurements for biomedical research, environmental monitoring and industrial production. In this regard, optically pumped magnetometers (OPMs) are considered as prominent candidates, but are impaired in size with micrometer scale magnetic particles, e.g. magnetic droplets. In order to address this limitation, here we study the effects of adding a micrometer-to-millimeter magnetic guide to a miniature OPM. This device is applied to detect Fe3O4 magnetic droplets flowing at rates up to 25 drop.¿s-1 in a microfluidic channel. The computed spatial resolution is 300¿µm and the measured signal-to-noise ratio is larger than 15¿dB for the different sizes of considered magnetic droplets., This work was financially supported by PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya and by CICYT PID2019-107885GB-C31 and Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Microwave imaging for Parkinson’s disease detection: A phantom-based feasibility study using temperature-controlled dielectric variations

  • Cardinali, Leonardo
  • Rodríguez Duarte, David Orlando
  • Tobón Vásquez, Jorge Alberto
  • Vipiana, Francesca
  • Jofre Roca, Lluís
Parkinson’s disease (PD) is characterized by pathological changes in the substantia nigra, which in its early stages may manifest as structural and functional asymmetries between the two hemispheres. Microwave imaging has recently emerged as a promising non-invasive tool to detect subtle dielectric variations. In the context of Parkinson’s disease, such contrasts are expected to arise from the underlying physiological alterations in brain tissue, although their magnitude has not yet been fully characterized. In this work, we investigate the feasibility of differential microwave imaging, where detection is based on permittivity contrasts, through a controlled phantom study. A simple two-dimensional head phantom was constructed using a 3D-printed cylindrical container filled with water, incorporating a Teflon tube to represent the substantia nigra. The tube was filled with hot water, whose gradual cooling emulated small dielectric changes. Since the dielectric properties of water vary linearly with temperature over 0.5–3 GHz, we first validated this dependence through both numerical analysis and experimental measurements. Four antennas were then employed in a differential imaging configuration, with image reconstruction performed via the multi-frequency bi-focusing algorithm. The results show that the system can successfully detect a dielectric contrast corresponding to a temperature variation as small as 0.4 °C, equivalent to approximately 0.17% in relative permittivity. While the exact dielectric changes associated with PD remain to be determined, these results demonstrate that the proposed approach is sensitive to very small contrasts, supporting the potential of differential microwave imaging as a candidate tool for future investigations into Parkinson’s disease detection., This work was supported in part by the project “THERAD—Microwave Theranostics for Alzheimer’s Disease”, funded by Compagnia di San Paolo; in part by the project “INSIGHTFOOD—An innovative microwave sensing system for the evaluation and monitoring of food quality and safety”, funded by the Italian Ministry of Foreign Affairs and International Cooperation (MAECI, CUP E13C23000180005); in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de lnvestigacion, Spain, under Grant CICYT PID2019-107885GBC31, Grant PID2022-136869NB-C31, and Grant Prueba de Concepto PDC2022-133091-IO0; and in part by Next Generation EU. It was carried out partially within the Agritech National Research Center, funded by the European Union Next—Generation EU (Piano Nazionale di Ripresa e Resilienza (PNRR)—MISSIONE 4 COMPONENTE 2, INVESTIMENTO 1.4—D.D. 1032 17/06/2022, CN00000022)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Microwave resonant wireless sensor for enhanced particle detection in microfluidic channels

  • Ataa-Allah, Houda
  • Ataa Allah, Fatima
  • Palacios Arias, César Augusto
  • Aznabet, Mariem
  • El mrabet, Otman
  • Jofre Cruanyes, Marc
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
This paper presents a highly sensitive microwave sensor for bioparticle detection, designed around a ring-gap resonator integrated with a microfluidic channel. The sensor’s structure is optimized to enhance electric field confinement, improving its sensitivity to dielectric variations. Experimental validation using commercial microbeads as bioparticle models demonstrates clear resonance shifts, confirming the sensor’s capability for precise detection of particles up to 5 µm. These results highlight the potential of the proposed approach for realtime, label-free biosensing applications, offering a promising tool for biomedical diagnostics and analytical chemistry., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de Investigación, Spain, under Grant CICYT PID2019- 107885GBC31, Grant PID2022-136869NB-C31, and Grant Prueba de Concepto PDC2022-133091-I00; and in part by the Next Generation EU. Additionally, this work is supported by the CNRST as part of the ”PhD-Associate Scholarship – PASS” Program., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Nonlinear microwave susceptibility measurements using intermodulation products on a microfluidic platform

  • Palacios Arias, César Augusto
  • Jofre Cruanyes, Marc
  • López Montero, María José
  • Akazzim, Youness
  • Jofre Cruanyes, Lluís
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Measuring the nonlinear responses of living cells has enabled an understanding of their behavior and functionality. Currently, this response has been studied at radio and optical frequencies, leaving an unexplored gap in the field of microwaves. This paper presents a system that combines microwave technology with a microfluidic platform to measure the nonlinear susceptibility of living organisms to electromagnetic fields. The applied technique involves feeding the system with two tones (2.1 GHz and 4 GHz) to generate third-order intermodulation products (PIMP) at 5.9 GHz. Nonlinear susceptibility was measured from the power levels of PIMP using a spectrum analyzer. Broadband electrodes based on the slot bowtie geometry were manufactured to operate at 5 GHz with a bandwidth of 4 GHz. Additionally, an engineering process is presented to optimize the power of the internal mixer of the spectrum analyzer to obtain the maximum dynamic range and improve the sensitivity of the system. Nonlinear susceptibility to microwaves was analyzed in four samples: pure ethanol, a mixture of ethanol and dimethyl sulfoxide (DMSO), live Escherichia coli (E. coli), and heat-killed E. coli. The results show that ethanol has zero nonlinear susceptibility, whereas when it is mixed with DMSO, a nonlinear response appears at a value of 4 dB with respect to the nonlinear susceptibility of the system in the absence of a sample. Finally, the nonlinear susceptibility of live E. coli to microwaves was detected, with a difference of 8 dB over the reference value and 6 dB with respect to the heat-killed E. coli sample., This work was supported in part by the Agencia Estatal de Investigación, Spain, under Grant PID2019-107885GB-C31, Grant PID 2022-136869NB-C31, and Grant PDC2022-133091-I00; in part by the Generalitat de Catalunya, Spain, under Grant PDR-2014-2022/56-30157-2021-2A; in part by the ‘‘Formación de Personal Investigador’’ Scholarship under Grant PID2019-107885GB-C31 and Grant PRE2020-093895; and in part by the Beatriz Galindo Program of the Ministerio de Ciencia, Innovación y Universidades, Spain, under Grant BGP18/00026., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Microwave contactless current-sensing for live/dead differentiation of single bioparticles on a microfluidic platform, Detección de corriente sin contacto de microondas para diferenciación en vivo/muerto de biopartículas individuales en una plataforma microfluidic

  • Palacios Arias, César Augusto
  • Jofre Cruanyes, Marc
  • Jofre Cruanyes, Lluís
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
© 2023 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., The combination of microwave and microfluidic technologies enables the creation of efficient platforms to rapidly quantify live/dead bioparticles in industrial processes, biomedical research and environmental monitoring applications. In this regard, this work demonstrates the differentiation of single live/dead bioparticles with a microwave-microfluidic platform. The system is composed of a contactless current-sensing superheterodyne architecture with broadband frequency-operation bowtie electrodes. Furthermore, the 20mm × 20mm bowtie electrode has been designed and manufactured with a –10 dB frequency range, from 4GHz to 8GHz, and capable of confining the electric field in a micrometric volume. The gap of the bowtie geometry of the electrodes is adjusted to the dimensions of the 50 µm × 50 µm cross-section and 40mm long microfluidic channel. In particular, 10mL sample with 10 9 bacteria/mL flows through the microchannel at 19.8 µL/min, focused with elasto-inertial effect enhanced with 500 ppm of polyethylene oxide. Accordingly, from the signal captured by the electrodes, the energy variation of the applied electric field produced by the bioparticles is sensed by a current-based transimpedance amplifier. Here, the incorporation of the transimpedance amplifier in the measurement system improves the SNR by 4 dB. In addition, the superheterodyne transceiver has been optimized in terms of local oscillator power and bandwidth. Furthermore, the microfluidic system has been adjusted so that the balance of hydrodynamic forces confines bioparticles at the centerline of the microchannel within less than 5 µm. As a result, the system measures the cytoplasmic content of live and dead flowing bacteria with a difference of 6 dB and relative deviation of 3.2%., This work was financially supported by the PID2019- 107885GB-C31 and PDC2022-133091-I00 grants of the Agencia Estatal de Investigación (Spain), and the PDR-2014- 2022/56-30157-2021-2A grant from Generalitat de Catalunya (Spain). In addition, the authors are grateful for the support provided by the Formación de Personal Investigador (PID2019-107885GB-C31, PRE2020-093895) scholarship and the Beatriz Galindo (BGP18/00026) program of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Qubit rate modulation-based time synchronization mechanism for multi-node quantum networks

  • Jofre Cruanyes, Marc
The combination of quantum and telecommunication networks enables to revolutionize the way information is used, offering unparalleled capabilities and making it an ideal choice for many critical applications. In this sense, quantum protocols generally have a unique requirement to have strict time synchronization in order to operate, which generally consume quantum resources of part of the exchanged qubits. Accordingly, work demonstrates and characterizes a temporal alignment mechanism for quantum networks based on frequency testing, allowing to preserve the quantum state of qubits. The time synchronization correction achieved is within 100 ns working at 5 MHz with temporal and relative frequency offsets commonly acquired in quantum links using conventional hardware clocks with temporal stability in the range of 10-8 and 200-ns jitter., This work was supported in part by the Agencia Estatal de Investigación (Spain) under Grant PID2022-137329OB-C41, Grant PID2022-136869NB-C31 (MCIN/AEI/10.13039/501100011033/FEDER, UE), Grant CNS2024-154600, and Grant PDC2022-133091-I00, in part by the Catalan Government University and Research Aid Management Agency (AGAUR) with Research Group under Grant 2021 SGR 01046, and in part by the Technical University of Catalonia (UPC) under Grant ALECTORS 2024., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Precision time protocol synchronization analysis for single and coincidence qubit detection in quantum networks

  • Jofre Cruanyes, Marc
  • Saigi, Ferran
  • Rincón Rivera, David
2025 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., The combination of Quantum and Telecommunications networks, offering unparalleled quantum correlation-based capabilities and making it an ideal choice for certain critical applications, requires precise time synchronization across network nodes. This work analytically and experimentally assessed the application of the IEEE 1588 Precision Time Protocol in achieving time synchronization within quantum networks. As results, operating at a repetition rate of 5MHz, the overall time synchronization precision is 65ns for single-qubit detection and 100ns for double-fold coincidence measurements. Correspondingly, the experimental results highlight the role of time-synchronization precision protocols in multi-node quantum networks and also provide insights for further developments for scalable quantum network infrastructure., This work was financially supported by PID2022-137329OB-C41 and PID2022-136869NB-C31 (MCIN / AEI / 10.13039 / 501100011033 / FEDER, UE), CNS2024-154600, PDC2022-133091-I00, grants of the Agencia Estatal de Investigaci´ on (Spain), Catalan Government University and Research Aid Management Agency (AGAUR) with Research Group grant 2021 SGR 01046, and ALECTORS 2024 grant from Universitat Polit` ecnica de Catalunya- BarcelonaTech (UPC)., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

OAM antennas for NLOS communications

  • Moriones Galve, Pau
  • Aldana Alonso, Rubén
  • Jofre Cruanyes, Marc
  • Molina García-Pardo, José María
  • Pascual García, Juan
  • Ferrando Bataller, Miguel
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
EM waves carrying orbital angular momentum (OAM) have been investigated in relation to their generation and transmission, with increasing interest in their usage and integration into modern communication systems. In the radio domain, the employment of a uniform circular array (UCA) featuring a consistent phase shift between neighboring elements is the most common technique employed in the literature to generate OAM carrying waves. Although offering an understandable solution, the consistent phase shift may not guarantee pure OAM generation and isolation between the different modes when interested on capacity increase with orthogonal multimodal solutions. In this work, the orientation of the elements in the antenna array is reviewed concerning collinear and radial arrangements of its elements, briefly analyzing the generation and transmission performance of different OAM eigenmodes, prioritizing short-range communication use cases. With respect to the latter, this report also addresses considerations about the performance evaluation of different OAM modes in the absence of clear LOS visibility under the aforementioned geometries., Grants PDR-2014-2022/56-30157-2021-2A, 2021 SGR 01415 Q0818003F, Metropolis PLEC2021-007609, PID2022-136869NB-C31, and PDC2022-133091-I00, Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Resonance-based microwave monitoring of live/dead bacteria in a microfluidic channel

  • Ataa-Allah, Houda
  • Aznabet, Mariem
  • Palacios Arias, César Augusto
  • Akazzim, Youness
  • El mrabet, Otman
  • Jofre Cruanyes, Marc
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
In this work, we have studied a highly sensitive microwave sensor for the detection of Escherichia coli (E. coli) bacteria at the single-cell level. The proposed system integrates a microwave sensor with a microfluidic channel for bacteria flow control. The microwave sensor is based on a planar microwave annular ring resonator working around 5GHz. Inside the channel, E. coli bacteria have been modeled using dielectric characteristics present in state-of-the-art literature. To enhance field confinement and achieve the highest electric field strength we have introduced two 50um gaps into the resonator. This approach holds great potential for different applications, including food safety control, healthcare diagnosis, and environmental monitoring, where the ability to detect a single E. coli cell is paramount., This work was financially supported in part by ID2019- 107885GBC31, PID2022-136869NB-C31, 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR) (2021 FISDU 00195), PDR-2014- 2022/56-30157-2021-2 Generalitat de Catalunya, and Prueba de Concepto PDC2022-133091-I00 Ministerio de Ciencia, Innovacion y Universidades (Spain)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Split-ring resonator based microwave microfluidic biosensor for single bioparticle position location and live/dead cell differentiation

  • Ataa-Allah, Houda
  • Ataa Allah, Fatima
  • Palacios Arias, César Augusto
  • Aznabet, Mariem
  • El mrabet, Otman
  • Jofre Cruanyes, Marc
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
© 2026 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This paper presents a novel microwave biosensor integrated with a microfluidic platform for the label-free detection and differentiation of biological particles, including live and dead Escherichia coli (E. coli). The sensor is based on a 50 O microstrip line coupled to an annular split-ring resonator (SRR), designed and fabricated for a high sensitivity response to changes in the dielectric properties on the bioparticle. The integration with a microfluidic channel allows precise control and delivery of biological samples to the sensing region. Experiments demonstrated the sensor’s ability to detect individual microbeads and distinguish between single live and dead bacterial cells through measurable shifts in resonance frequency. Furthermore, by applying an Inverse Fast Fourier Transform (IFFT) to the differential transmission parameter, the system enables the spatial localization of single particles within the microfluidic channel. The results indicate significant potential for point-of-care diagnostics and environmental monitoring applications, highlighting the advantages of microwave biosensing for real-time, single-particle analysis., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC 2021-007609, in part by the Agencia Estatal de Investigación, Spain under Grant CICYT PID2019107885GB-C31, Grant PID2022-136869NB-C31 funded byMICIU / AEI / 10.13039 / 501100011033/ FEDER, UE, and Grant Prueba de Concepto PDC 2022-133091-I00, in part by NextGeneration EU, in part by the CNRST as part of the “PhD-AssociateScholarship–PASS” Program., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Accurate and time-efficient electromagnetic scattering analysis of thick impenetrable planar structures

  • Úbeda Farré, Eduard
  • Heldring, Alexander
  • Tapia Folch, Núria
  • Rius Casals, Juan Manuel
© 2025 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., The scattering analysis of perfectly conducting plates, with very small electrical thickness, in the free space is normally carried out through the zero-thickness approximation, which arises from modelling the whole closed surface enclosing the plate as an open surface. The resulting accuracy, though acceptable in many practical applications, deteriorates drastically for growing plate thicknesses or under grazing-angle incidence. In this paper, we provide a thorough description of the recently proposed thick-plate approach, which, while maintaining the agile single-mesh management of the zero-thickness scheme, offers improved accuracy with restricted computational overhead for a wider range of plate thicknesses or plane wave incidences. The computed thick-plate RCS solution deviation as compared with the zero-thickness and full method-of-moment solutions is quantified for an illustrative variety of flat perfectly conducting structures with different electrical dimensions, shapes (rectangular or circular), rim contour (straight or rounded) and plane wave incidence (perpendicular or grazing)., This work is part of the R&D projects PID2020-118410RB-C21, PID2023- 146245OB-C21, PID2022-136869NB-C31, PDC2022-133091-I00 funded by MICIU/AEI/10.13039/501100011033/FEDER/UE (Agencia Estatal de Investigación, Spain and the UE), and the Research Group 2021 SGR 01415 funded by the Catalan Agency for Management of University and Research Grants (AGAUR)., Peer Reviewed, 8 - Treball Decent i Creixement Econòmic, 8.2 - Aconseguir nivells més elevats de productivitat econòmica mitjançant la diversificació, la modernització tecnològica i la innovació, entre d’altres maneres centrant l’atenció en sectors de més valor afegit i ús intensiu de mà d’obra, 8.4 - Millorar progressivament, per a 2030, la producció i el consum eficients dels recursos mundials i procurar desvincular el creixement econòmic de la degradació del medi ambient, de conformitat amb el Marc decennal de programes sobre modalitats sostenibles de consum i producció, començant pels països desenvolupats, 9 - Indústria, Innovació i Infraestructura, 9.4 - Per a 2030, modernitzar les infraestructures i reconvertir les indústries perquè siguin sostenibles, usant els recursos amb més eficàcia i promovent l’adopció de tecnologies i processos industrials nets i racionals ambientalment, i aconseguint que tots els països adoptin mesures d’acord amb les capacitats respectives, 9.5 - Augmentar la investigació científica i millorar la capacitat tecnològica dels sectors industrials de tots els països, en particular els països en desenvolupament, entre d’altres maneres fomentant la innovació i augmentant substancialment, d’aquí al 2030, el nombre de persones que treballen en el camp de la investigació i el desenvolupament per cada milió d’habitants, així com la despesa en investigació i desenvolupament dels sectors públic i privat, 12.6 - Encoratjar les empreses, en especial les grans empreses i les empreses transnacionals, a adoptar pràctiques sostenibles i a incorporar informació sobre la sostenibilitat en el seu cicle de presentació d’informes, 12 - Producció i Consum Responsables, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

UWB-modulated microwave imaging for human brain functional monitoring

  • Akazzim, Youness
  • Jofre Cruanyes, Marc
  • El Mrabet, Otman
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Morphological microwave imaging has shown interesting results on reconstructing biological objects inside the human body, and these parameters represent their actual biological condition, but not their biological activity. In this paper, we propose a novel microwave technique to locate the low-frequency (f≃1 kHz) -modulated signals produced by a microtag mimicking an action potential and proved it in a cylindrical phantom of the brain region. A set of two combined UWB microwave applicators, operating in the 0.5 to 2.5 GHz frequency band and producing a nsec interrogation pulse, is able to focus its radiated field into a small region of the brain containing the microtag with a modulated photodiode. The illuminating UWB microwave field was first modulated by the low-frequency (f≃1 kHz) electrical signal produced by the photodiode, inducing modulated microwave currents into the microtag that reradiating back towards the focusing applicators. At the receiving end, the low-frequency (f≃1 kHz) -modulated signal was first extracted from the full set of the backscattered signals, then focused into the region of interest and spatially represented in the corresponding region of the brain, resulting in a spatial resolution of the images in the order of 10 mm., This work was financially supported by the CICYT PID2019-107885GB-C31 and PDC2022-133091-I00 grants of the Agencia Estatal de Investigacion (Spain) and the PDR-2014-2022/56-30157-021-2A grant from Generalitat de Catalunya (Spain), as well as support grants for university departments and research units (FI-SDUR) (2021 FISDU 00195). This work was also supported by the National Center for Scientific and Technological Research (CNRST) under Grant Number PPR2/2015/36., Peer Reviewed, Postprint (published version)