Pasar al contenido principal

SISTEMAS RADIANTES “X-WAVE” INTEGRADAS DE COMUNICACIONES Y SENSORIZACION

PID2019-107885GB-C31

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 97
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Vehicular mm-Wave Array for Smart Handover

  • Bharath Reddy, G.
  • Ramirez, G. A.
  • Molins-Benlliure, Jaime
  • Romeu, J.
  • Jofre-R., L.
  • Ferrando Bataller, Miguel|||0000-0003-3561-5112
[EN] The emergence of new technologies such as autonomous vehicles and high data rate 5G networks requires advanced antenna types that are capable of fulfilling requirements for highly demanding wireless communication links. The array of microstrip-fed slot-coupled patches is one such type of antenna that provides low return loss and good transient behaviour for broadband applications. A compact size slot-coupled patch antenna subarray and its phased array is proposed in this paper. Two different substrates Rogers TMM4 and Green TapeTM 951 Low Temperature Co-Fired Ceramic (LTCC) are considered for the fabrication of microstrip feedline. The feedline is fabricated on the respective substrates and then mounted on a Rogers RT/duroid 5880 laminate. Ground planes are used on both the front and backside of the antenna array. The antenna is operating in a range of 24.25 GHz - 29.5 GHz. A Smart Array is proposed in this paper which has a good performance in terms of antenna gain and scanning property for 5G application in Smart handovers., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects TEC2016-78028-C3-1- P, PID 2019-107885GB-C31, MDM2016-0600, and Catalan Research Group 2017 SGR 219.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

UWB microwave functional brain activity extraction for Parkinson's disease monitoring

  • Akazzim, Youness|||0000-0002-7957-4044
  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • El Mrabet, Otman
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Microwaves have proven their imaging capabilities to visualize the body composition for medical applications, thanks to their penetration inside biological structures. In this context, this article presents a novel methodology that aims to extract not just the internal morphology, but also the brain’s functional activity using the UWB pulse amplitude modulation (PAM) technique to have simultaneously functional monitoring and imaging capability and apply it to monitor the Parkinson’s disease (PD). The radio-frequency system is composed of two orthogonal sets of double UWB probes operating in the frequency range of 0.5–1.5 GHz. An experimental setup has been devised that avoids complex in vivo testing, albeit allows a system proof-of-concept validation. A bio-tag (BT) consisting of an optically modulated photodiode is used to emulate local medium changes associated with cell activity. The proposed system is used to first extract the modeled brain action potential (AP) to validate the performance of the BT and then to monitor the PD based on the beta frequency band character within basal ganglia–thalamocortical (BGTC) which is a key marker for the PD. The results show a good capability of locating and differentiating the signals generated within the phantom by the BT, alternatively emulating the healthy and PD’s state, based on the frequency. The obtained results of the functional monitoring technique on distinguishing the healthy from nonhealthy brain model activity, as well as in the phantom mimicking the average proprieties of a human head, will serve as a basis for detecting functional diseases in the future., This work was supported in part by Comision Interministerial de Ciencia y Tecnologia (CICYT) PID2019-107885GB-C31, PID2022-136869NB-C31, Catalan Research Group 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR) under Grant 2021 FISDU 00195; in part by the PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya; and in part by the Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Split-ring resonator based microwave microfluidic biosensor for single bioparticle position location and live/dead cell differentiation

  • Ataa-Allah, Houda
  • Ataa Allah, Fatima
  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Aznabet, Mariem
  • El mrabet, Otman
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
© 2026 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This paper presents a novel microwave biosensor integrated with a microfluidic platform for the label-free detection and differentiation of biological particles, including live and dead Escherichia coli (E. coli). The sensor is based on a 50 O microstrip line coupled to an annular split-ring resonator (SRR), designed and fabricated for a high sensitivity response to changes in the dielectric properties on the bioparticle. The integration with a microfluidic channel allows precise control and delivery of biological samples to the sensing region. Experiments demonstrated the sensor’s ability to detect individual microbeads and distinguish between single live and dead bacterial cells through measurable shifts in resonance frequency. Furthermore, by applying an Inverse Fast Fourier Transform (IFFT) to the differential transmission parameter, the system enables the spatial localization of single particles within the microfluidic channel. The results indicate significant potential for point-of-care diagnostics and environmental monitoring applications, highlighting the advantages of microwave biosensing for real-time, single-particle analysis., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC 2021-007609, in part by the Agencia Estatal de Investigación, Spain under Grant CICYT PID2019107885GB-C31, Grant PID2022-136869NB-C31 funded byMICIU / AEI / 10.13039 / 501100011033/ FEDER, UE, and Grant Prueba de Concepto PDC 2022-133091-I00, in part by NextGeneration EU, in part by the CNRST as part of the “PhD-AssociateScholarship–PASS” Program.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Mie scattering with 3D angular spectrum method

  • Lamberg, Joel
  • Zarrinkhat, Faezeh
  • Tamminen, Aleksi
  • Ala-Laurinaho, Juha
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Khaled, Elsayed E. M.
  • Taylor, Zachary
Mie theory is a powerful method to model electromagnetic scattering from a multilayered sphere. Usually, the incident beam is expanded to its vector spherical harmonic representation defined by beam shape coefficients, and the multilayer sphere scattering is obtained by the T-matrix method. However, obtaining the beam shape coefficients for arbitrarily shaped incident beams has limitations on source locations and requires different methods when the incident beam is defined inside or outside the computational domain or at the scatterer surface. We propose a 3D angular spectrum method for defining beam shape coefficients from arbitrary source field distributions. This method enables the placement of the sources freely within the computational domain without singularities, allowing flexibility in beam design. We demonstrate incident field synthesis and spherical scattering by comparing morphology-dependent resonances to known values, achieving excellent matching and high accuracy. The proposed method has significant benefits for optical systems and inverse beam design. It allows for the analysis of electromagnetic forward/backward propagation between optical elements and spherical targets using a single method. It is also valuable for optical force beam design and analysis., Agencia Estatal de Investigación (PID2019-107885GB282 C31/AEI/10.13039, PRE2018-084326); Assessment of the Graft 281 Rejection Using Millimeter Waves; Academy of Finland (327640)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Wireless sensing of concrete setting process

  • González López, Giselle
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Cairó, Ignasi
  • Segura Pérez, Ignacio|||0000-0001-6519-9899
  • Ikumi Montserrat, Tai|||0000-0001-9547-5241
  • Jofre Roca, Lluís|||0000-0002-0547-901X
An RFID-based wireless system to measure the evolution of the setting process of cement-based materials is presented in this paper. The system consists of a wireless RFID temperature sensor that works embedded in concrete, and an external RFID reader that communicates with the embedded sensor to extract the temperature measurement conducted by the embedded sensor. Temperature time evolution is a well known proxy to monitor the setting process of concrete. The RFID sensor consisting of an UWB Bow Tie antenna with central frequency 868 MHz, matched to the EM4325 temperature chip through a T-match structure for embedded operation inside concrete is fully characterized. Results for measurements of the full set up conducted in a real-scenario are provided, This work was supported by the Spanish “Comision Interministerial de Ciencia y Tecnologia” (CICYT) under projects PID2019-107885GB-C31 / AEI / 10.13039/501100011033, MDM2016-0600, and by the “Unidad de Excelencia María de Maeztu”, 2017–2020., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Ultra-wideband narrow wall waveguide-to-microstrip transition using overlapped patches

  • Zhou, Ivan
  • Romeu Robert, Jordi|||0000-0003-0197-5961
An ultrawideband rectangular waveguide to microstrip line transition operating at the whole LMDS and Ka band is presented. The transition is based on exciting three overlapped transversal patches that radiate into the narrow wall of the waveguide, making the design feasible to be used in ¿g/2 spaced phased arrays. Both top-side and bottom-side versions were designed and compared to show their differences. They were validated by means of a manufactured back-to-back (B2B) configuration, with a measured fractional bandwidth of 21.2% (top-side) and 23% (bottom-side). The maximum single transition measured insertion losses were 0.67 dB (top-side) and 0.85 dB (bottom-side) in the whole band of operation, This work was supported by the Spanish “Comision Interministerial de Ciencia y Tecnologia” (CICYT) under projects DI2020-043, Agencia Estatal de Investigación PID2019-107885GBC31/AEI/ 10.13039, and Catalan Research Group 2017 SGR 219., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Coherent UD-WDM RoF Fronthaul network with D-EML transmitter and phase-noise robust receiver

  • Masanas Jiménez, Miquel|||0000-0001-7500-4872
  • Tabares Giraldo, Jeison
  • Prat Gomà, Josep Joan|||0000-0002-9817-4695
This work proposes and tests a simplified coherent uplink architecture for ultra-dense coherent analog mobile Fronthaul with phase noise cancellation based on single sideband modulation of a dual-EML. Results show optical channel spacings of only 1.5 GHz and error-free signal recovery with Δν Tb = 1.2% and 3% with reaching power as low as −46dBm for 100 Mbit/s and −38 dBm for 1 Gbit/s using QPSK modulation., This work was supported by the Spanish Comisión Interministerial de Ciencia y Tecnología (CICYT) Project Versatile Coherent Dual Optical Network (VERSONET) under Grant RTI2018-097051 and in part by the Grant “Proyectos de I+D+i” under Grant PID2019-107885GB- C31., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

M-Port rotationally symmetric antennas for advanced MIMO applications

  • Aldana Alonso, Rubén
  • Molins Benlliure, Jaime
  • Akazzim, Youness|||0000-0002-7957-4044
  • Llanga Vargas, Anibal
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Cabedo Fabrés, Marta
  • Antonino Daviu, Eva
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Ferrando Bataller, Miguel
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Multiple-input multiple-output (MIMO) technology has emerged as a highly promising solution for wireless communication, offering an opportunity to overcome the limitations of traffic capacity in high-speed broadband wireless network access. By utilizing multiple antennas at both the transmitting and receiving Sub-6GHz ends, the MIMO system enhances the efficiency and performance of wireless communication systems [1]. This work presents a comparison of the performance of two families of M-Rotationally Symmetrical MIMO antenna design approaches one based on the Magneto Electric (ME) dipole antenna and a second one based on the Circular Cavity principle intended for their use into advanced MIMO applications like Orthogonal Angular Momentum (OAM) and high capacity channels. A comparison of the relevant performance parameters in terms of frequency bandwidth (both input impedance 𝑺𝒊𝒊 and inter-port isolation 𝑺𝒊j) and radiation pattern are presented for the two Sub-6GHz prototypes., This work was financially supported by PDR-20142022/56-30157-2021-2A grant of the Generalitat de Catalunya and by CICYT PID2019-107885GB-C31, PID2019107885GB-C32, PID2022-136869NB-C31, PID2022136869NB-C33, and Prueba de Concepto PDC2022, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

UWB-modulated microwave imaging for human brain functional monitoring

  • Akazzim, Youness|||0000-0002-7957-4044
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • El Mrabet, Otman
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Morphological microwave imaging has shown interesting results on reconstructing biological objects inside the human body, and these parameters represent their actual biological condition, but not their biological activity. In this paper, we propose a novel microwave technique to locate the low-frequency (f≃1 kHz) -modulated signals produced by a microtag mimicking an action potential and proved it in a cylindrical phantom of the brain region. A set of two combined UWB microwave applicators, operating in the 0.5 to 2.5 GHz frequency band and producing a nsec interrogation pulse, is able to focus its radiated field into a small region of the brain containing the microtag with a modulated photodiode. The illuminating UWB microwave field was first modulated by the low-frequency (f≃1 kHz) electrical signal produced by the photodiode, inducing modulated microwave currents into the microtag that reradiating back towards the focusing applicators. At the receiving end, the low-frequency (f≃1 kHz) -modulated signal was first extracted from the full set of the backscattered signals, then focused into the region of interest and spatially represented in the corresponding region of the brain, resulting in a spatial resolution of the images in the order of 10 mm., This work was financially supported by the CICYT PID2019-107885GB-C31 and PDC2022-133091-I00 grants of the Agencia Estatal de Investigacion (Spain) and the PDR-2014-2022/56-30157-021-2A grant from Generalitat de Catalunya (Spain), as well as support grants for university departments and research units (FI-SDUR) (2021 FISDU 00195). This work was also supported by the National Center for Scientific and Technological Research (CNRST) under Grant Number PPR2/2015/36., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Fast analysis and optimization of sparsely distributed partial modification problems

  • Fang, Xiaoxing
  • Heldring, Alexander|||0000-0003-2011-2096
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
  • Cao, Qunsheng
This article addresses the efficient numerical analysis of sparsely distributed small modifications in a large structure, that is, the sparsely distributed partial modification problem (SDPMP). A hierarchical matrix (H-matrix)-based fast direct solver is adopted to solve the SDPMP in a very short time for each new set of modifications. The main idea of this method is to reuse the parts of the compressed inverse matrix operator that do not change and only recompute the modified parts. In contrast with already existing algorithms designed to tackle a single localized modification, this new approach is still very fast for sparsely distributed small modifications, so it becomes a very attractive option to solve optimization problems efficiently, due to the very cheap analysis of the modified structure at each iteration of the optimization procedure. The efficiency of the solution of SDPMP is demonstrated for several cases involving passive and active metasurfaces and a reconfigurable antenna. As a practical example, a programmable metasurface reflector is optimized with particle swarm optimization to obtain a prescribed reflection pattern., This work was supported in part by the National Nature Science Foundation of China under Grant 61871219; in part by the China Scholarship Council under Grant 201906830042; in part by the Startup Foundation for Introducing Talent of the Nanjing University of Information Science and Technology (NUIST) under Grant 2022r079; in part by the Ministerio de Ciencia e Innovacion (MICINN) under Project PID2019- 107885GB-C31/AEI/10.13039/501100011033, Project PID2020-113832RBC21/AEI/10.13039/501100011033, and Project TEC2017-84817-C2-2-R/AEI/ 10.13039/501100011033; and in part by the Unidad de Excelencia Maria de Maeztu, which is financed by the Agencia Estatal de Investigación, Spain, under Grant MDM-2016-0600/AEI/10.13039/501100011033; and in part by the Catalan Agency for Management of University and Research Grants (AGAUR) under Research Group under Grant 2017 SGR 219., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Vector spherical harmonic analysis and experimental validation of spherical shells illuminated with broadband, millimeter wave Gaussian beams: applications to corneal sensing

  • Zarrinkhat, Faezeh
  • Lamberg, Joel
  • Tamminen, Aleksi
  • Baggio, Mariangela
  • Nefedova, Irina
  • Ala-Laurinaho, Juha
  • Khaled, Elsayed E. M.
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
  • Taylor, Zachary
Coupling to longitudinal modes of thin spherical shells, under Gaussian-beam illumination, was explored with a theoretical method based on Fourier-optics analysis and vector spherical harmonics and was scrutinized with an experimental setup. For the theory part, the illumination frequency band was fixed between 100–600 GHz and the outer spherical shell radius of curvature and thickness are 7.5 mm and 0.5 mm, respectively. The shell material was either the lossless cornea or an aqueous effective media representing the cornea. Six different beam-target strategies were introduced being potential candidates for maximum coupling. Two dispersion-tuned beam ensembles with strongly frequency-dependent phase center location have been created with a fixed incident beam 1/e radius and radius of curvature called forward strategies. These computations of different alignments were continued with four beam ensembles of frequency-invariant phase center, constructed from fits to experimental data, oriented at four different axial locations with respect to the spherical shell center of curvature, they are called reverse strategies. Coupling efficiency for all strategies was calculated for different targets including perfect electrical conductor (PEC) sphere, PEC core covered by a cornea loss-free layer and cornea. All scattering strategies contrasted to scattering from equivalent planar targets as a reference with maximum coupling. The results show that, under an ideal calibration, forward strategies are a closer approximation to the plane-wave condition for the cornea. An experimental setup was assembled to explore the simulation approach in a frequency range between 220 GHz to 330 GHz. Two different quartz samples with permittivity of 4.1 were mounted on a water core, acting for a cornea. The first and second quartz radius and thickness were 7.5 mm and 0.5 mm and 8 mm and 1 mm, respectively. An adequate agreement between theory and experiment was confirmed. A particle optimisation swarm algorithm was applied to extract the thickness and permittivity of quartz from the measured back-scattered field for reverse strategies., Funding. Agencia Estatal de Investigación (PID2019-107885GB-C31/AEI/10.13039, PRE2018-084326); Academy of Finland (327640)., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Low-Profile UWB probe for precise time-domain functional imaging

  • Akazzim, Youness|||0000-0002-7957-4044
  • El Mrabet, Otman
  • Jofre Roca, Lluís|||0000-0002-0547-901X
In this paper a Double Ridge Waveguide (DRW) antenna fed by a microstrip line covering a frequency band from 0.5GHz to 2.5GHz is designed, fabricated, and measured, for functional microwave imaging. The proposed DRW antenna is used as the probe element in a collateral multi-static system to detect a cylindrical target located inside a human brain liquid medium. Also, an approach for the spatial reconstruction accuracy based on maximum time resolution is presented. Measured and simulated results are conducted and discussed., This work was financially supported by CICYT PID2019- 107885GB-C31, MDM2016-0600, and support grants for university departments and research units (FI-SDUR)(2021 FISDU 00195). This work was supported by the National Center for Scientific and Technological Research (CNRST) under grant number PPR2/2015/36., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Short asymmetrical inductive dipole antenna for direct matching to high-Q chips

  • Ballesteros Sánchez, Christian|||0000-0002-4395-9057
  • Vega Piña, Sara|||0000-0002-4853-7929
  • Santos Blanco, M. Concepción|||0000-0002-5103-5356
  • Jofre Roca, Lluís|||0000-0002-0547-901X
A planar antenna structure based on a folded asymmetrical dipole is presented, whose geometrical parameters are seen to independently determine either the real or the imaginary parts of the complex radiation impedance. This unique feature allows very efficient and wide-band conjugate matching coupling to non-conventional RF sources of arbitrary internal impedance, i.e., small resistance with large and negative reactance. The antenna theoretical framework is developed and an optimized design to match a photodiode is manufactured and measured. The results show a fractional bandwidth of about 20% in the 28 GHz band., This work was supported by the Spanish Ministry of Economy thanks to the project PID2019-107885GB-C31, the Catalan Research Group 2017 SGR 219, and the Ministry of Education with pre-doctoral grant FPU17/05561 to the first author., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Magnetoelectric dipole antenna framework supporting orbital angular momentum modes

  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Akazzim, Youness|||0000-0002-7957-4044
  • Blanch Boris, Sebastián|||0000-0002-8757-583X
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Cetiner, Bedri Artug
  • Jofre Roca, Lluís|||0000-0002-0547-901X
The ability to utilize resources to meet the need of growing diversity of communication services and user behavior marks the future of cognitive wireless communication systems. Cognitive wireless technologies for vehicular communications, in combination with Orbital Angular Momentum (OAM) modes aim at extending Non-Line-Of-Sight (NLOS) short-distance communications for smart mobility. In this regard, OAM antenna frameworks need to be developed to support these technologies. In this work, we describe a magnetoelectric dipole antenna framework supporting OAM modes. The framework is derived from moment tensors of specific vector spherical harmonic functions synthesized from dipoles. The antenna framework is discussed in terms of OAM generation, and it is validated numerically and experimentally for l = 1 OAM mode, achieving more than 500MHz operation bandwidth at the frequency of operation of 3.5GHz. Also, for l = 1 OAM mode, the null aligns precisely with the anticipated dimensions numerically computed., This work was financially supported by PDR-2014-2022/56-30157-2021-2A, 2021 SGR 01415 Q0818003F and Metropolis PLEC2021-007609 grants of the Generalitat de Catalunya and European Regional Development Fund (FEDER), by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31 and Prueba de Concepto PDC2022-133091-I00 grants of the Agencia Estatal de Investigación (Spain) and Next Generation EU., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Microwave contactless current-sensing for live/dead differentiation of single bioparticles on a microfluidic platform, Detección de corriente sin contacto de microondas para diferenciación en vivo/muerto de biopartículas individuales en una plataforma microfluidic

  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Jofre Cruanyes, Lluís|||0000-0003-2437-259X
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
© 2023 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., The combination of microwave and microfluidic technologies enables the creation of efficient platforms to rapidly quantify live/dead bioparticles in industrial processes, biomedical research and environmental monitoring applications. In this regard, this work demonstrates the differentiation of single live/dead bioparticles with a microwave-microfluidic platform. The system is composed of a contactless current-sensing superheterodyne architecture with broadband frequency-operation bowtie electrodes. Furthermore, the 20mm × 20mm bowtie electrode has been designed and manufactured with a –10 dB frequency range, from 4GHz to 8GHz, and capable of confining the electric field in a micrometric volume. The gap of the bowtie geometry of the electrodes is adjusted to the dimensions of the 50 µm × 50 µm cross-section and 40mm long microfluidic channel. In particular, 10mL sample with 10 9 bacteria/mL flows through the microchannel at 19.8 µL/min, focused with elasto-inertial effect enhanced with 500 ppm of polyethylene oxide. Accordingly, from the signal captured by the electrodes, the energy variation of the applied electric field produced by the bioparticles is sensed by a current-based transimpedance amplifier. Here, the incorporation of the transimpedance amplifier in the measurement system improves the SNR by 4 dB. In addition, the superheterodyne transceiver has been optimized in terms of local oscillator power and bandwidth. Furthermore, the microfluidic system has been adjusted so that the balance of hydrodynamic forces confines bioparticles at the centerline of the microchannel within less than 5 µm. As a result, the system measures the cytoplasmic content of live and dead flowing bacteria with a difference of 6 dB and relative deviation of 3.2%., This work was financially supported by the PID2019- 107885GB-C31 and PDC2022-133091-I00 grants of the Agencia Estatal de Investigación (Spain), and the PDR-2014- 2022/56-30157-2021-2A grant from Generalitat de Catalunya (Spain). In addition, the authors are grateful for the support provided by the Formación de Personal Investigador (PID2019-107885GB-C31, PRE2020-093895) scholarship and the Beatriz Galindo (BGP18/00026) program of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Microwave resonant wireless sensor for enhanced particle detection in microfluidic channels

  • Ataa-Allah, Houda
  • Ataa Allah, Fatima
  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Aznabet, Mariem
  • El mrabet, Otman
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
This paper presents a highly sensitive microwave sensor for bioparticle detection, designed around a ring-gap resonator integrated with a microfluidic channel. The sensor’s structure is optimized to enhance electric field confinement, improving its sensitivity to dielectric variations. Experimental validation using commercial microbeads as bioparticle models demonstrates clear resonance shifts, confirming the sensor’s capability for precise detection of particles up to 5 µm. These results highlight the potential of the proposed approach for realtime, label-free biosensing applications, offering a promising tool for biomedical diagnostics and analytical chemistry., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de Investigación, Spain, under Grant CICYT PID2019- 107885GBC31, Grant PID2022-136869NB-C31, and Grant Prueba de Concepto PDC2022-133091-I00; and in part by the Next Generation EU. Additionally, this work is supported by the CNRST as part of the ”PhD-Associate Scholarship – PASS” Program., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

On the influence of fabrication tolerances in Terahertz photoconductive antennas

  • Vega Piña, Sara|||0000-0002-4853-7929
  • Nuño Gómez, Daniel-Juan|||0000-0002-2418-6351
  • Chang, Yi
  • Gómez Díaz, J. Sebastián
  • Santos Blanco, M. Concepción|||0000-0002-5103-5356
© 2025 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., We present a study of the radiation pattern of photoconductive antennas (PCA) subject to substrate chip defects, aiming at characterizing fabrication tolerances. We show that the asymmetries observed over the cross-polar radiation patterns may be exploited to numerically estimate the most prominent trends of the substrate chip geometrical imperfections. A Figure of Merit (FoM) has been defined, characterized and validated through simulations and experimental measures, proving it is sensitive to both the magnitude and location of the substrate irregularities. The study has been focused on two kinds of substrate defects, the angled dicing and the off-centered antenna gap, and it has considered three planar antenna geometries: dipole, bow-tie and Sierpinski triangle dipole. A numerical antenna factor related to the planar antenna geometry imprinted over the substrate is included in the FoM expression for fair comparison of substrate irregularities among PCAs with different metallic patterns. A simple setup for experimentally obtaining the value of the FoM through collimated beam raster scanning measure of the cross-polar radiation pattern has been proved useful to validate the practical relevance of the FoM. These values asses the substrate chip fabrication quality and help to identify the position and magnitude of the substrate defects that have the greatest impact on the PCA performance., This work was supported by the Spanish Ministerio de Ciencia e In- novaci´on (MICINN) thanks to the project PID2019-107885GB-C31 VER- SONET (RTI2018-097051), the Catalan Research Group grant 2017 SGR 219 and the University and Research Aid Management Agency (AGAUR) with pre-doctoral grant 2021 FISDU 00094 to the first author. (Corresponding author: Sara Vega), Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Nested fast adaptive cross approximation algorithm for solving electromagnetic scattering problems

  • Fang, Xiaoxing
  • Heldring, Alexander|||0000-0003-2011-2096
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
  • Chen, Xinlei
  • Cao, Qunsheng
In this paper, a Nested Fast Adaptive Cross Approximation (NFACA) algorithm is presented to accelerate the solution of electromagnetic scattering problems. It is based on the Fast Adaptive Cross Approximation (FACA) and the Nested Cross Approximation (NCA). In the NFACA, the FACA is applied instead of the ACA or the Chebyshev nodes, to enhance the efficiency. It is shown to have O(N) storage and computational complexity for electrically small problems. Different from the conventional NCA or the Fast Nested Cross Approximation (FNCA), the pivot-selection does not rely on a preliminary selection with Chebyshev nodes or ACA for each group. The NFACA permits the selection of the optimum pivots independently at each level to make the accuracy controllable. Numerical results of several objects are presented to demonstrate the performance of this method. Compared with the FACA and NCA in solving the electromagnetic scattering problems, the NFACA is more efficient both in computational cost and storage. Compared with the FNCA, the NFACA is both faster and more accurate., This work was supported in part by the National Nature Science Foundation of China under Grant 61871219, Grant 61771238, and Grant 61501227; in part by the Post-Graduate Research and Practice Innovation Program of Jiangsu Province under Grant KYCX18_0289; in part by the China Scholarship Council under Grant 201906830042; in part by the Spanish Ministerio de Ciencia e Innovacion (MICINN) under Project TEC2016-78028-C3-1-P, Project PID 2019-107885GB-C31, Project TEC2017-83343-C4-2-R, and Project MDM2016-0600; and in part by the Catalan Research Group 2017 SGR 219., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Calibration alignment sensitivity in corneal terahertz imaging

  • Zarrinkhat, Faezeh
  • Baggio, Mariangela
  • Lamberg, Joel
  • Tamminen, Aleksi
  • Nefedova, Irina
  • Ala-Laurinaho, Juha
  • Khaled, Elsayed E. M.
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Taylor, Zachary
Improving the longitudinal modes coupling in layered spherical structure contributes significantly to corneal terahertz sensing, which plays a crucial role in the early diagnosis of cornea dystrophies. Using a steel sphere to calibrate reflection from the cornea sample assists in enhancing the resolution of longitudinal modes. The requirement and challenges toward applying the calibration sphere are introduced and addressed. Six corneas with different properties are spotted to study the effect of perturbations in the calibration sphere in a frequency range from 100 GHz to 600 GHz. A particle-swarm optimization algorithm is employed to quantify corneal characteristics considering cases of accurately calibrated and perturbed calibrated scenarios. For the first case, the study is carried out with signal-to-noise values of 40 dB, 50 dB and 60 dB at waveguide bands WR-5.1, WR-3.4, and WR-2.2. As expected, better estimation is achieved in high-SNR cases. Furthermore, the lower waveguide band is revealed as the most proper band for the assessment of corneal features. For perturbed cases, the analysis is continued for the noise level of 60 dB in the three waveguide bands. Consequently, the error in the estimation of corneal properties rises significantly (around 30%)., This research was funded by the Agencia Estatal de Investigación PID2019-107885GB-C31/AEI/10.13039, PRE2018-084326, and Academy of Finland Project number 327640., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

MIMO radar antenna with sectorial human torso illumination for an in-cabin breathing detection system

  • López Montero, María José|||0000-0002-2286-7479
  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
The vital sign measurement systems inside vehicles have taken great or impulse in recent years, and the technologies that have been most welcomed are based on wireless measurements that do not interrupt driving and are imperceptible to the driver. There are disorders in breathing patterns, which include the movement of different regions of the human thorax mainly. In this sense, the objective of this paper is to determine the dimensions of a lens-based antenna system and the pointing angles of the radiation main lobe of the six antenna-elements to measure the elongation of six regions of the human torso and determine breathing patterns. The pointing angle is controlled by the position of the antenna behind the lens, and the beamwidth of the lobe depends on the directivity achieved by the antenna. An electronic system to simulate torso elongation is also presented to calibrate and test the sensitivity of the system., This work was supported by the Spanish “Comisión Interministerial de Ciencia y Tecnologia” (CICYT) under projects PID2019-107885GB-C31 and MDM2016-O6OO; Catalan Research Group 2017 SGR 219; and ”Secretaría Nacional de Educación Superior, Ciencia, Tecnología e Innovación” (SENESCYT) from the Ecuadorian government., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

In-cabin MIMO radar system for human dysfunctional breathing detection

  • López Montero, María José|||0000-0002-2286-7479
  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
The integration of wireless sensors into the automotive industry is making vehicles increasingly safe and autonomous. At present, vehicles are equipped with external sensors that facilitate maneuverability and braking and internal sensors that detect presence, seat belt state, and occupant vital signs. Early detection of dysfunctional breathing patterns can reduce the risk of accidents caused by drowsiness or fatigue. In this regard, this work presents an MIMO FMCW Radar System able to distinguish dysfunctional breathing patterns from human torso motion. The torso has been divided into six regions, and the amplitude of the elongation and the frequency of motion of each region have been measured during breathing. An elongation map is then constructed in order to graphically show the dysfunctional breathing patterns. The signal processing includes a peak search algorithm to detect elongation amplitude and a bandpass frequency filter to minimize dc components, random driver motion, and vehicle vibration. A torso elongation emulator phantom has been assembled with materials of skin-like relative permittivity and dc motors for calibration and validation of basic breathing patterns. Finally, the signal of the system is compared with that of a commercial respiration belt, and then the system is tested by performing measurements on people. The MIMO radar system is able to measure, differentiate, and classify patterns associated with dysfunctional breathing such as hyperventilation syndrome and thoracic dominant breathing., This work was supported in part by the Spanish “Comision Interministerial de Ciencia y Tecnologia” (CICYT) under Project PID2019-107885GB-C31 and Project MDM2016- 0600, in part by the Catalan Research Group under Grant 2017 SGR 219, and in part by the “Secretaría Nacional de Educación Superior, Ciencia, Tecnología e Innovación” (SENESCYT) from the Ecuadorian Government, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Improvements in randomized matrix compression methods for numerical analysis of antennas and scatterers

  • López Menchón, Héctor|||0000-0001-5776-1423
  • Heldring, Alexander|||0000-0003-2011-2096
  • Úbeda Farré, Eduard|||0000-0001-6759-0445
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
We propose a randomized Pseudo Skeleton (or CUR) Approximation method to compress the H-matrices of linear systems that arise in the discretization of integral equations in electromagnetic scattering. This method is highly parellelizable and well suited for fine-granularity architectures as GPUs. As the Adaptive Approximation Method (ACA), the method is purely algebraic. The method is tested with standard cases to assess its quality and efficiency, This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019-107885GBC31 / AEI / 10.13039/501100011033, PID2020-113832RBC21 / AEI / 10.13039/501100011033 and PID-2020-118410RB-C21 / AEI / 10.13039/501100011033, PDC2022-133091-I00 / AEI / 10.13039/501100011033, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Microwave monitoring of Parkinson disease using a realistic human head model

  • Akazzim, Youness|||0000-0002-7957-4044
  • Gugliermino, Martina
  • Rodríguez Duarte, David Orlando
  • Tobón Vásquez, Jorge Alberto
  • Vipiana, Francesca
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Parkinson's disease (PD) is a widespread neurode-generative disorder characterized by the loss of dopaminergic neurons from the substantia nigra, causing bradykinesia, tremors, rigidity, and postural instability. In this paper, we present a differential microwave imaging study (MWI) for early-stage PD monitoring that uses the dielectric properties of the basal ganglia, particularly the thalamus. The simulations are carried out using two scenarios: one is based on studying the sensitivity of a realistic human head model. The other is the study of differential microwave imaging to monitor the PD based on the dopamine level changes in the basal ganglia. The MWI system contains 24 printed flexible antennas with a custom-made matching medium covering the head model. The obtained results demonstrate that small variations in dielectric properties within the human head, in particular the thalamus, can be detected, which can be used to monitor Parkinson's disease in a very early stage., This work was financially supported in part by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31, 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR)(2021 FISDU 00195), PDR-2014-2022/56-30157-2021-2 A grant of the Generalitat de Catalunya, and Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovacion y Universidades (Spain). This work was supported in part by the project PON Research and Innovation “Microwave Imaging and Detection powered by Artificial Intelligence for Medical and Industrial Applications (DM 1062/21)”, funded by MUR. It was carried out partially within the Agritech National Research Center, funded by the Next-Generation EU (PNRR, Missione 4, Componente 2, Investimento 1.4, D.D. 1032 17/06/2022, CN00000022., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Supervised machine learning assisted driving stress monitoring MIMO radar system

  • López Montero, María José|||0000-0002-2286-7479
  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Factors such as road traffic, challenging ambient temperature conditions, and extended periods of driving have detrimental effects on the physical and mental well-being of a driver. These factors can alter the stress levels, thereby diminishing his or her capacity to make effective decisions when faced with hazardous situations on the road. In this regard, this study presents a novel approach utilizing a multiple-input multiple-output (MIMO) radar system to accurately assess driver stress levels by measuring both physiological signals and driving behavior. The proposed method, assisted by a machine learning technique, provides comprehensive insights to classify the stress level of a driver into three states: drowsiness, awakeness, and anxiety. The MIMO radar system captures the elongation distance and velocity of six specific regions of the frontal torso of the driver in an advanced driving simulator based on virtual reality. This allows for the extraction of vital physiological parameters such as heart rate, respiratory rhythm, and breathing patterns over time, as well as the identification of changes in driving style determined by variations in their relative position in the seat and control of the steering wheel. Then, a fully connected neural network (FCNN) model is trained with the acquired data, and its performance is evaluated with volunteers submitted to different driving situations that induce stress in the driver. The findings show an accuracy in drowsiness detection of 90%, awakeness of 96% and anxiety of 85%., This work was supported by the Spanish “Comision Interministerial de Ciencia y Tecnologia” (CICYT) under projects PID2019-107885GB-C31, PID2022-136869NB-C31 and MDM2016-O6OO; Catalan Research Group 2017 SGR 219; and ”Secretaría Nacional de Educación Superior, Ciencia, Tecnología e Innovación” (SENESCYT) from the Ecuadorian government., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Simple randomized strategies for low-rank matrix compression

  • López Menchón, Héctor|||0000-0001-5776-1423
  • Molina Burgués, Robert|||0009-0005-1314-3742
  • Heldring, Alexander|||0000-0003-2011-2096
  • Úbeda Farré, Eduard|||0000-0001-6759-0445
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
We propose a randomized Pseudo Skeleton (or CUR) approximation method to compress the H-matrices of linear systems that arise in the discretization of integral equations in electromagnetic scattering. This method is essentially the Matrix Decomposition Algorithm (MDA) of Michielssen and Boag (1994) with equivalent basis and testing functions equal to a random subset of the original ones. It is highly parellelizable and well suited for fine-granularity architectures as GPUs. As the Adaptive Cross Approximation (ACA), CUR is purely algebraic. The method is tested with standard cases to assess its quality and efficiency., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019-107885GBC31 / AEI / 10.13039/501100011033, PID2022-136869NBC31 / AEI / 10.13039/501100011033, PID2020-113832RBC21 / AEI / 10.13039/501100011033 and PID-2020-118410RB-C21 / AEI / 10.13039/501100011033, PDC2022-133091-I00 / AEI / 10.13039/501100011033, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Technology assessment of aperture coupled slot antenna array in Groove Gapwaveguide for 5G millimeter wave applications

  • Zhou, Ivan
  • Jofre Roca, Lluís|||0000-0002-0547-901X
  • Romeu Robert, Jordi|||0000-0003-0197-5961
A compact triple-layer series fed slot unit array using Groove Gap Waveguide (GGW) technology for 5G millimeter-wave applications is presented in this paper. The design employed a two-step coupling mechanism for the radiating slots. The aperture coupling design when combined with the groove gapWaveguide (GGW) technology allows achieving three different goals: First, a reduction of the array size in the transversal direction, so more unit arrays can be added without grating lobes. Secondly, low insertion losses with high radiation efficiency. And third, a reduction of the manufacturing complexity with good stability against fabrication tolerances of up to 0.1 mm, making the design feasible to be massively deployed. The antenna was fabricated and measured showing good agreement with the numerical simulation results, the antenna provides a peak realized gain of 12.15dB at the central frequency of operation and a fractional bandwidth (FBW) of 9%., This work was supported in part by the Agencia Estatal Investigación under Grant PID2019-107885GB-C31/AEI/10.13039; and in part by the Catalan Research Group under Grant 2017SGR219, Grant MDM2016-O6OO, and Grant DI2020-043., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Acceleration of Born series by change of variables

  • López Menchón, Héctor|||0000-0001-5776-1423
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
  • Heldring, Alexander|||0000-0003-2011-2096
  • Úbeda Farré, Eduard|||0000-0001-6759-0445
In this work, we propose a method to enhance the convergence of the Born series. The Born series is widely used in scattering theory, but its convergence is only guaranteed under certain restrictive conditions which limit the cases where this formulation can be applied. The proposed method, based on modifying the singularities of the resolvent operator by a change of variables, accelerates the convergence of the series or even achieves convergence in otherwise divergent cases. Due to its low computational cost and ease of implementation, the method preserves the advantages of the Born series while it extends its range of application. It can also be applied to a variety of methods relying on the same mathematical principles as the Born series. Numerical examples are provided to show that a significant improvement can be achieved with simple techniques and with a limited knowledge about the operator spectrum., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects TEC2016-78028-C3-1-P, MDM2016-0600, TEC2017-83343-C4-2-R, TEC2017-84817-C2-2-R, PID 2019-107885GB-C31 and Catalan Research Group 2017 SGR 219; and by Secretary of Universities and Research of the Ministry of Business and Knowledge of the Generalitat of Catalonia and European Social Fund under scholarship 2019 FI B00788., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Microstrip-fed 3D-printed H-sectorial horn phased array

  • Zhou, Ivan
  • Pradell i Cara, Lluís|||0000-0003-4026-226X
  • López Villegas, José María
  • Vidal Martínez, Neus
  • Albert Gali, Miquel
  • Jofre Roca, Lluís|||0000-0002-0547-901X
  • Romeu Robert, Jordi|||0000-0003-0197-5961
A 3D-printed phased array consisting of four H-Sectorial horn antennas of 200 g weight with an ultra-wideband rectangular-waveguide-to-microstrip-line transition operating over the whole LMDS and K bands (24.25–29.5 GHz) is presented. The transition is based on exciting three overlapped transversal patches that radiate into the waveguide. The transition provides very low insertion losses, ranging from 0.30 dB to 0.67 dB over the whole band of operation (23.5–30.4 GHz). The measured fractional bandwidth of the phased array including the transition was 20.8% (24.75–30.3 GHz). The antenna was measured for six different scanning angles corresponding to six different progressive phases α, ranging from 0° to 140° at the central frequency band of operation of 26.5 GHz. The maximum gain was found in the broadside direction α = 0°, with 15.2 dB and efficiency η = 78.5%, while the minimum was found for α = 140°, with 13.7 dB and η = 91.2%., This work was supported by MINISTERIO DE CIENCIA, INNOVACIÓN Y UNIVERSIDADES: PID2019-107885GB-C31/AEI/10.13039/501100011033 and DI-2020., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Automatic polyp detection using microwave endoscopy for colorectal cancer prevention and early detection: phantom validation

  • Garrido Atienza, Alejandra|||0000-0003-1371-8962
  • Sont Colomer, Roberto
  • Dghoughi, Walid
  • Marcoval Martínez, Sergi
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Fernández-Esparrach, Glòria
  • Belda Reig, Ignasi
  • Guardiola Garcia, Marta
A system to integrate microwave imaging with optical colonoscopy is presented. The overarching goal is to improve the prevention and early diagnosis of one of the main health and economic burdens of an increasingly aging population, i.e., colorectal cancer. For a colonoscopy, the gold standard for colorectal cancer diagnosis, 22% of polyps are not detected, and the risk of cancer after a negative colonoscopy can be up to 7.9%. To remedy this, a microwave imaging system able to generate an alarm when a polyp is detected is designed, manufactured and validated with a colon phantom composed of tissue-mimicking oil-gelatin materials reproducing the anatomy and dielectric properties of a human colon with a polyp. The acquisition was performed by a miniaturized ring-shaped switched array of 16 antennas attachable at the tip of a conventional colonoscope. This has been conceived to satisfy endoscopy size restrictions, patient safety and intercompatibility with current clinical practice. A Modified Monofocusing imaging method preceded by a previous frame average subtraction as a calibration technique shows a perfect detection of a 10-mm polyp (100% sensitivity and specificity) in the eight analyzed trajectories. The phantom results demonstrate the feasibility of the system in future preclinical trials., The work of Alejandra Garrido was supported by DIN2019-010857. The work of Roberto Sont, Ignasi Belda, and Marta Guardiola was supported in part by the European Union’s Horizon 2020 Research and Innovation Programme under Grant 960251 and in part by the European Institute of Innovation and Technology (EIT). The work of Jordi Romeu was supported by PID2019-107885GB-C31/AEI/10.13039/501100011033., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Magnetòmetre de bombeig òptic amb guia magnètica d’elevada resolució espacial per a detectar gotes magnètiques en un canal microfluídic

  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Els sensors quàntics proporcionen una sensitivitat sense precedents per a detectar camps magnètics, fet que els permet ampliar l’abast habitual d’aplicacions i de contextos d’ús de la magnetometria. Moltes aplicacions també requereixen mesures magnètiques d’elevada resolució espacial en recerca biomèdica, monitoratge ambiental i producció industrial. En aquest aspecte, els magnetòmetres de bombeig òptic (OPM) són candidats destacats, però tenen limitacions a l’escala de les partícules magnètiques micromètriques, per exemple, gotes magnètiques. Per tractar aquesta limitació, aquí estudiem els efectes d’afegir una guia magnètica que fa de pont entre micròmetres i mil·límetres a un OPM en miniatura. Aquest instrument s’utilitza per a detectar gotes magnètiques de Fe3O4 a un flux de fins a 25 gotes per segon en un canal microfluídic. La resolució espacial calculada és de 300 µm i la relació senyal-soroll és més gran que 15 dB per a les diferents mides de gota magnètica estudiades., Aquest estudi ha estat finançat per l’ajuda DR-2014-2022/56-30157-2021-2A de la Generalitat de Catalunya i les ajudes ICYT PID2019-107885GB-C31 i Prueba de Concepto PDC2022-133091-I00 del Ministeri de Ciència, Innovació i Universitats (Espanya).
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Multi-element UWB probe optimization for medical microwave imaging

  • Akazzim, Youness|||0000-0002-7957-4044
  • El Mrabet, Otman
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
The need for non-ionizing techniques for medical imaging applications has led to the use of microwave signals. Several systems have been introduced in recent years based on increasing the number of antennas and frequency bandwidth to obtain high resolution and good accuracy in locating objects. A novel microwave imaging system that reduces the number of required antennas for precise target location appropriate for medical applications is presented. The proposed system consists of four UWB extended gap ridge horn (EGRH) antennas covering the frequency band from 0.5 GHz to 1.5 GHz mounted on a cylindrical phantom that mimics the brain in an orthogonal set of two EGRH probes. This configuration has the ability to control both the longitudinal and transversal dimensions of the reconstructed target’s image, rather than controlling the spatial resolution, by increasing the frequency band that can be easily affected by medium losses. The system is tested numerically and experimentally by the detection of a cylindrical target within a human brain model., This work was financially supported by CICYT PID2019-107885GB-C31, and support grants for university departments and research units (FI-SDUR)(2021 FISDU 00195). This work was also supported by the National Center for Scientific and Technological Research (CNRST) under grant number PPR2/2015/36., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Enhanced robustness of a bridge-type Rf-Mems switch for enabling applications in 5G and 6G communicationsr

  • Casals Terré, Jasmina|||0000-0002-1368-3950
  • Pradell i Cara, Lluís|||0000-0003-4026-226X
  • Heredia, Julio
  • Giacomozzi, Flavio
  • Iannacci, Jacopo
  • Contreras Lizárraga, Adrián
  • Ribó Pal, Miquel
In this paper, new suspended-membrane double-ohmic-contact RF-MEMS switch configurations are proposed. Double-diagonal (DDG) beam suspensions, with either two or three anchoring points, are designed and optimized to minimize membrane deformation due to residual fabrication stresses, thus exhibiting smaller mechanical deformation and a higher stiffness with more release force than previously designed single diagonal beam suspensions. The two-anchor DDGs are designed in two different orientations, in-line and 90¿ -rotated. The membrane may include a window to minimize the coupling to the lower electrode. The devices are integrated in a coplanar-waveguide transmission structure and fabricated using an eight-mask surface-micro-machining process on high-resistivity silicon, with dielectric-free actuation electrodes, and including glass protective caps. The RF-MEMS switch behavior is assessed from measurements of the device S parameters in ON and OFF states. The fabricated devices feature a measured pull-in voltage of 76.5 V/60 V for the windowed/not-windowed two-anchor DDG membranes, and 54 V/49.5 V for the windowed/notwindowed three-anchor DDG membranes, with a good agreement with mechanical 3D simulations. The measured ON-state insertion loss is better than 0.7 dB/0.8 dB and the isolation in the OFF state is better than 40 dB/31 dB up to 20 GHz for the in-line/90¿ -rotated devices, also in good agreement with 2.5D electromagnetic simulations
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Solving electromagnetic scattering in dielectric bodies by Monte Carlo sampling

  • López Menchón, Héctor|||0000-0001-5776-1423
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
  • Úbeda Farré, Eduard|||0000-0001-6759-0445
  • Heldring, Alexander|||0000-0003-2011-2096
In this work, we propose Monte Carlo sampling as a technique to avoid communication overhead in the numerical solution of complex electromagnetic scattering problems. The method is based on statistically sampling a formal representation of the solution of the scattering problem, based on a modified Born series. The sampling process can be independently carried out in different processors with no need for communication between them. This lack of communication makes the algorithm suitable for massively parallel computational environments., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019-107885GB-C31 / AEI / 10.13039/501100011033, PID2020-113832RB- C21 / AEI / 10.13039/501100011033 and TEC2017- 84817-C2-2-R / AEI / 10.13039/501100011033 and the Unidad de Excelencia Maria de Maeztu MDM-2016- 0600/AEI/10.13039/501100011033, which is financed by the Agencia Estatal de Investigaci ´on, Spain, and Catalan Research Group 2017 SGR 219, and Ag`encia de Gesti ´o d’Ajuts Uni- versitaris i de Recerca with grant 2021 FI B2 00096., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Improving the accuracy of the adaptive cross approximation with a convergence criterion based on random sampling

  • Heldring, Alexander|||0000-0003-2011-2096
  • Úbeda Farré, Eduard|||0000-0001-6759-0445
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
The accuracy of the Adaptive Cross Approximation (ACA) algorithm, a popular method for the compression of low rank matrix blocks in Method of Moment computations, is sometimes seriously compromised by unpredictable errors in the convergence criterion. This paper proposes an alternative criterion, based on global sampling of the error in the elements of the ACA compressed matrix. The sampling error depends on the size of the sample but also on the population distribution of the error, which makes it difficult to control the error independently of the underlying problem. However, as argued and demonstrated in the paper, the distribution of the error converges to the same unique probability distribution function for all low rank matrices. Complementing the sampling criterion with a simple mechanism to detect this convergence, we arrive at a criterion that controls the error irrespective of the underlying problem. As a practical example the RCS of a moderate size metallic ogive is computed to illustrate the merits of the proposed criterion. The proposed algorithm may also be useful in other methods that approximate low-rank matrices by interpolation of a reduced set of its elements., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects TEC2016-78028-C3-1-P, TEC2017-84817-C2-2-R, TEC2017-83343-C4-2-R, PID 2019-107885GBC31, MDM2016-0600, and Catalan Research Group 2017 SGR 219., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Efficient analysis of thick curved metal sheets

  • Úbeda Farré, Eduard|||0000-0001-6759-0445
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
The scattering analysis of perfectly conducting plates with the method-of-moment discretization of the Electric-Field Integral Equation has been traditionally carried out according to the thin-sheet approximation, which neglects the current contributions over the plate rims. The plate is then modelled as an open surface and handles a restricted number of unknowns as compared with the canonical modelling as a closed object. The thin-sheet approximation, although used in many practical applications, becomes inaccurate for thick enough plates or plates under plane wave incidence at grazing angles. Recently, a thick-plate approach has been presented to address the time-efficient and accurate scattering analysis of thick plates. This scheme exploits the symmetry properties of fields and currents thereby giving rise to two uncoupled problems with roughly half the number of unknowns of the original problem. In this paper, we extend this thick-plate scheme to the efficient scattering analysis of thick curved sheets., This work was supported by FEDER and the "Spanish Plan Estatal de Investigación Científica y Técnica y de Innovación", under projects: TEC2017-84817-C2-2-R/ AEI/10.13039/501100011033, TEC2016-78028-C3-1-P/AEI/10.13039/501100011033, PID2019-107885GB-C31/AEI/10.13039/501100011033 and the Unidad de Excelencia Maria de Maeztu MDM-2016-0600/AEI/10.13039/501100011033, which is financed by the Agencia Estatal de Investigación, Spain, and Catalan Research Group 2017 SGR 219., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Resonance-based microwave monitoring of live/dead bacteria in a microfluidic channel

  • Ataa-Allah, Houda
  • Aznabet, Mariem
  • Palacios Arias, César Augusto|||0000-0003-1298-8434
  • Akazzim, Youness|||0000-0002-7957-4044
  • El mrabet, Otman
  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
In this work, we have studied a highly sensitive microwave sensor for the detection of Escherichia coli (E. coli) bacteria at the single-cell level. The proposed system integrates a microwave sensor with a microfluidic channel for bacteria flow control. The microwave sensor is based on a planar microwave annular ring resonator working around 5GHz. Inside the channel, E. coli bacteria have been modeled using dielectric characteristics present in state-of-the-art literature. To enhance field confinement and achieve the highest electric field strength we have introduced two 50um gaps into the resonator. This approach holds great potential for different applications, including food safety control, healthcare diagnosis, and environmental monitoring, where the ability to detect a single E. coli cell is paramount., This work was financially supported in part by ID2019- 107885GBC31, PID2022-136869NB-C31, 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR) (2021 FISDU 00195), PDR-2014- 2022/56-30157-2021-2 Generalitat de Catalunya, and Prueba de Concepto PDC2022-133091-I00 Ministerio de Ciencia, Innovacion y Universidades (Spain)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

A multiparametric advection-diffusion reduced-order model for molecular transport in scaffolds for osteoinduction

  • Muixí Ballonga, Alba|||0000-0002-4420-3366
  • Zlotnik, Sergio|||0000-0001-9674-8950
  • Calvet Tordera, Pere
  • Español Pons, Montserrat|||0000-0001-7510-0602
  • Lodoso Torrecilla, Irene|||0000-0003-1849-5243
  • Ginebra Molins, Maria Pau|||0000-0002-4700-5621
  • Díez, Pedro|||0000-0001-6464-6407
  • García González, Alberto|||0000-0003-2841-016X
The version of record is available online at: http://dx.doi.org/10.1007/s10237-022-01577-2, Scaffolds are microporous biocompatible structures that serve as material support for cells to proliferate, differentiate and form functional tissue. In particular, in the field of bone regeneration, insertion of scaffolds in a proper physiological environment is known to favour bone formation by releasing calcium ions, among others, triggering differentiation of mesenchymal cells into osteoblasts. Computational simulation of molecular distributions through scaffolds is a potential tool to study the scaffolds’ performance or optimal designs, to analyse their impact on cell differentiation, and also to move towards reduction in animal experimentation. Unfortunately, the required numerical models are often highly complex and computationally too costly to develop parametric studies. In this context, we propose a computational parametric reduced-order model to obtain the distribution of calcium ions in the interstitial fluid flowing through scaffolds, depending on several physical parameters. We use the well-known Proper Orthogonal Decomposition (POD) with two different variations: local POD and POD with quadratic approximations. Computations are performed using two realistic geometries based on a foamed and a 3D-printed scaffolds. The location of regions with high concentration of calcium in the numerical simulations is in fair agreement with regions of bone formation shown in experimental observations reported in the literature. Besides, reduced-order solutions accurately approximate the reference finite element solutions, with a significant decrease in the number of degrees of freedom, thus avoiding computationally expensive simulations, especially when performing a parametric analysis. The proposed reduced-order model is a competitive tool to assist the design of scaffolds in osteoinduction research., The authors acknowledge the financial support from the Ministerio de Ciencia e Innovación (MCIN/ AEI/10.13039/501100011033) through the grants PID2020-113463RBC32, PID2020-113463RB-C33, CEX2018-000797-S and PID2019-103892RB-I00, and the Generalitat de Catalunya for the Serra Hunter Fellowship of ME and the ICREA Academia Award of MPG., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

A GPU parallel randomized CUR compression method for the Method of Moments

  • López Menchón, Héctor|||0000-0001-5776-1423
  • Heldring, Alexander|||0000-0003-2011-2096
  • Úbeda Farré, Eduard|||0000-0001-6759-0445
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
In this work, we propose a GPU parallel implementation of the randomized CUR (or Pseudo Skeleton) Approximation to compress the -matrices of linear systems that arise in the discretization of integral equations modeling electromagnetic scattering problems. This compression method is highly parallelizable, in contrast with other similar methods such as the Adaptive Cross Approximation. It involves dense linear algebra computations that can be efficiently implemented on a GPU device. Besides, a stochastic convergence criterion is introduced to minimize the communication between the host and the device. Testing the code with standard cases shows the efficiency and accuracy of the method., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019- 107885GB-C31 / AEI / 10.13039/501100011033, PID2020-113832RB-C21 / AEI / 10.13039/501100011033 and PID-2020-118410RB- C21 / AEI / 10.13039/501100011033, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Magnetoelectric dipole antenna extending NLOS short-distance vehicular communication with orbital angular momentum modes

  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Akazzim, Youness|||0000-0002-7957-4044
  • Towfiq, Asaduzzaman
  • Cetiner, Bedri Artug
  • Blanch Boris, Sebastián|||0000-0002-8757-583X
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
The ability to utilize resources to meet the need of growing diversity in services and user behavior marks the future of cognitive wireless communication systems. Cognitive wireless technologies for vehicular communications, in combination with Orbital Angular Momentum (OAM) modes aim at extending direct Non-Line-Of-Sight (NLOS) short-distance communications for smart mobility. In this regard, OAM antennas need to be developed to support these technologies. To this end, here we describe a compact antenna supporting the first OAM modes. Also, the antenna properties are discussed and are numerically and experimentally validated for OAM modes of l=±1 . Particularly, for the considered OAM modes, the antenna achieves more than 500 MHz operation bandwidth at the frequency of operation of 3.5 GHz. Also, for l=±1 OAM modes, the null beamwidth aligns precisely with the anticipated dimensions theoretically computed., This work was financially supported by PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya and by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31 and Prueba de Concepto PDC2022-133091-I00 and Metropolis PLEC2021-007609 grants of the Ministerio de Ciencia, Inno-vación y Universidades (Spain).
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Lens based switched beam antenna for a 5G smart repeater

  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Blanch Boris, Sebastián|||0000-0002-8757-583X
  • Pradell i Cara, Lluís|||0000-0003-4026-226X
  • Barlabe Dalmau, Antoni|||0000-0002-1176-1329
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
  • Albert Galí, Miquel
  • Jofre Roca, Lluís|||0000-0002-0547-901X
  • Mazzucco, Christian
  • Flamini, Roberto
A 16 switched beam lens based antenna with a coverage area of ±30° in the horizontal plane and from 0 to -20° in the vertical plane has been built and tested. The intended use of the antenna is as part of a smart repeater servicing the coverage area of a 5G wireless communication system operating in the n258 band of the 5G Frequency Range 2, from 24.25 to 27.5 GHz. The antenna has been built using state-of-the-art materials and components in order to assess the performance of this antenna concept. The overall antenna losses including the feeding network are of the order of 8 dB and the realized gain in the 80% of the coverage area is above 11 dB., This work was funded in part by AEI: PID2019-107885GB-C31/AEI/10.13039/501100011033 and HUAWEI TECHNOLOGIES Italia S.r.l, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Optically pumped magnetometer with high spatial resolution magnetic guide for the detection of magnetic droplets in a microfluidic channel

  • Jofre Cruanyes, Marc|||0000-0002-8912-6595
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Quantum sensors provide unprecedented magnetic field detection sensitivities, enabling these to extend the common magnetometry range of applications and environments of operation. In this framework, many applications also require high spatial resolution magnetic measurements for biomedical research, environmental monitoring and industrial production. In this regard, optically pumped magnetometers (OPMs) are considered as prominent candidates, but are impaired in size with micrometer scale magnetic particles, e.g. magnetic droplets. In order to address this limitation, here we study the effects of adding a micrometer-to-millimeter magnetic guide to a miniature OPM. This device is applied to detect Fe3O4 magnetic droplets flowing at rates up to 25 drop.¿s-1 in a microfluidic channel. The computed spatial resolution is 300¿µm and the measured signal-to-noise ratio is larger than 15¿dB for the different sizes of considered magnetic droplets., This work was financially supported by PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya and by CICYT PID2019-107885GB-C31 and Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Microwave imaging for Parkinson’s disease detection: A phantom-based feasibility study using temperature-controlled dielectric variations

  • Cardinali, Leonardo
  • Rodríguez Duarte, David Orlando
  • Tobón Vásquez, Jorge Alberto
  • Vipiana, Francesca
  • Jofre Roca, Lluís|||0000-0002-0547-901X
Parkinson’s disease (PD) is characterized by pathological changes in the substantia nigra, which in its early stages may manifest as structural and functional asymmetries between the two hemispheres. Microwave imaging has recently emerged as a promising non-invasive tool to detect subtle dielectric variations. In the context of Parkinson’s disease, such contrasts are expected to arise from the underlying physiological alterations in brain tissue, although their magnitude has not yet been fully characterized. In this work, we investigate the feasibility of differential microwave imaging, where detection is based on permittivity contrasts, through a controlled phantom study. A simple two-dimensional head phantom was constructed using a 3D-printed cylindrical container filled with water, incorporating a Teflon tube to represent the substantia nigra. The tube was filled with hot water, whose gradual cooling emulated small dielectric changes. Since the dielectric properties of water vary linearly with temperature over 0.5–3 GHz, we first validated this dependence through both numerical analysis and experimental measurements. Four antennas were then employed in a differential imaging configuration, with image reconstruction performed via the multi-frequency bi-focusing algorithm. The results show that the system can successfully detect a dielectric contrast corresponding to a temperature variation as small as 0.4 °C, equivalent to approximately 0.17% in relative permittivity. While the exact dielectric changes associated with PD remain to be determined, these results demonstrate that the proposed approach is sensitive to very small contrasts, supporting the potential of differential microwave imaging as a candidate tool for future investigations into Parkinson’s disease detection., This work was supported in part by the project “THERAD—Microwave Theranostics for Alzheimer’s Disease”, funded by Compagnia di San Paolo; in part by the project “INSIGHTFOOD—An innovative microwave sensing system for the evaluation and monitoring of food quality and safety”, funded by the Italian Ministry of Foreign Affairs and International Cooperation (MAECI, CUP E13C23000180005); in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de lnvestigacion, Spain, under Grant CICYT PID2019-107885GBC31, Grant PID2022-136869NB-C31, and Grant Prueba de Concepto PDC2022-133091-IO0; and in part by Next Generation EU. It was carried out partially within the Agritech National Research Center, funded by the European Union Next—Generation EU (Piano Nazionale di Ripresa e Resilienza (PNRR)—MISSIONE 4 COMPONENTE 2, INVESTIMENTO 1.4—D.D. 1032 17/06/2022, CN00000022)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

High-sensitivity microwave resonator sensor for aqueous glucose detection using field-concentrating elements

  • Ataa Allah, Fatima
  • Ataa-Allah, Houda
  • El mrabet, Otman
  • Aznabet, Mariem
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
In this article, we present a highly sensitive microwave sensor for determining the concentration of aqueous glucose solutions in the microwave regime. The proposed sensor is based on a single split-ring resonator (SRR) printed on a Rogers RO3003 substrate and operates at 2.9 GHz. The sensitivity of this sensor is enhanced by using a narrow gap of approximately 100 µm, which increases the capacitance of the SRR and, more importantly, produces a localized field enhancement within the gap region. Moreover, the proposed design operates with only 2 µL of sample, a notable improvement over sensors that typically require larger liquid volumes. Both the simulation and measurement results showed a clear linear shift in the resonance frequency over a concentration range of 0–400 mg/dL, with the ability to detect minimal concentration variations as small as 50 mg/dL. These results confirm the effectiveness of the sensor for noninvasive glucose detection and represent a significant advancement in the field of microwave sensing., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de Investigación, Spain, under Grant CICYT PID2019-107885GB- C31, PID2022-136869NB-C31 MICIU / AEI / 10.13039 / 501100011033/ FEDER, UE, and Grant Prueba de Concepto PDC2022-133091-I00; and in part by the Next Generation EU. Additionally, this work is supported by the CNRST as part of the ”PhD-Associate Scholarship– PASS” Program., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Rayleigh backscattering rejection in single-laser homodyne transceiver for UD-WDM using λ-Shifting

  • Masanas Jiménez, Miquel|||0000-0001-7500-4872
  • Santos Blanco, M. Concepción|||0000-0002-5103-5356
  • Tabares Giraldo, Jeison
  • Polo Querol, Víctor|||0000-0002-8939-9411
  • Prat Gomà, Josep Joan|||0000-0002-9817-4695
With the aim of using a single laser per transceiver in single fiber splitter-based passive optical networks (PON) with coherent homodyne receivers, we apply wavelength shifting in an ultra-dense wavelength division multiplexing (UD-WDM) scheme. The studied architecture is based on a dual-parallel Mach-Zehnder Modulator (DP-MZM) operating in carrier-suppressed single-sideband (CS-SSB). In this configuration, a single laser feeds both the coherent homodyne receiver, and the transmitter, simplifying the wavelength management in the PON. The modulator carries out both data modulation and wavelength shifting. In this study, a bit rate of 4 Gb/s in QPSK is used to test several roll-off factors and channel spacing configurations. The results show that power budget gains of 18 dB are achievable with a channel spacing equal to only the symbol rate., This work was supported in part by the Spanish CICYT Project VERSONET under Grant RTI2018-097051, in part by Proyectos de I+D+i under Grant PID2019-107885GB-C31, and in part by María de Maeztu under Grant MDM2016-0600., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Preliminary phantom-based dynamic calibration techniques assessment for microwave colonoscopy systems

  • Garrido Atienza, Alejandra|||0000-0003-1371-8962
  • Dghoughi, Walid
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Guardiola Garcia, Marta
Early detection and resection of colon polyp is the best way to reduce colorectal cancer (CRC) mortality. The current method for early detection is colonoscopy, which has a limited field of view, and its efficacy is highly dependant on the endoscopist's experience and colon preparation. This work presents a device for combining microwave imaging with optical colonoscopy. The challenges of this new microwave imaging system are presented, such as the unknown distance to the colon mucosa, which leads to undesired scattered fields and, the antenna size limitations. Four dynamic calibration techniques are proposed to remove the effects of the undefined distance from the imaging region to colon mucosa. These calibration methods are based on averaging the colonoscopy trajectory frames and subtracting the calibration set from the current frame. The phantom preliminary results show that these calibration methods completely delete the undesired scatter., A.G. acknowledges the financial support from DIN2019- 010857, M.G., and W.D acknowledge the financial support from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 960251 and from the European Institute of Innovation and Technology (EIT). J.R. acknowledges the financial support from Agencia Estatal Investigacion PID2019-107885GB-C31/AEI/10.13039/., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Characterization of THz radiation by collimated wavefront aperture raster scanning

  • Nuño Gómez, Daniel-Juan|||0000-0002-2418-6351
  • Santos Blanco, M. Concepción|||0000-0002-5103-5356
  • Gomez Diaz, J. Sebastian
  • Romeu Robert, Jordi|||0000-0003-0197-5961
  • Jofre Roca, Lluís|||0000-0002-0547-901X
We present measurements for characterization of the beam profile and polarization pattern of lens-coupled photoconductive antennas (PCAs) at THz frequencies using a setup with antennas at fixed positions and a movable aperture placed in between collimating THz lenses. The measured beam patterns for co-polar and cross-polar components reveal the expected Airy disc and quadrupole behavior, respectively. The temporal evolution of the polarization in the directions of maximum cross-polar component follows a single-cycle circle with opposite handedness at each side of the antennas line-of-sight (LOS). Results are consistent with those obtained with fiber-coupled movable antennas, while enjoying the simplicity of a free-space laser-PCA feed which does not require painstaking laser realignment for each beam direction measure., This work was partly funded by the Ministerio de Economía y Competitividad under projects TEC2016-78028-C3-1-P, PID 2019-107885GB-C31 and MDM2016-0600, and Catalan Research Group 2017 SGR 219., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Optical beam steering network with multiband capability

  • Vega, Sara
  • Nuño Gómez, Daniel-Juan|||0000-0002-2418-6351
  • Santos Blanco, M. Concepción|||0000-0002-5103-5356
A multiwavelength (MW) optical true time delay Network (OTTDN) to feed a phased array antenna (PAA) is presented. Beam steering capabilities can be demonstrated when applying MW tuning. A Dual Electrode Mach Zehnder Modulator (DE-MZM) as radio frequency (RF) external modulating stage allows to tune the operative band avoiding severe Chromatic Dispersion (CD) fading to obtain a flattened response. A working example simulation of a 4 elements array at 8 GHz shows the RF multiband spectral flat response potential of the technique, as well as the network conditions needed for beam steering with free-lobe operation., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects TEC2016-78028-C3-1- P, PID 2019-107885GB-C31, MDM2016-0600, and Catalan Research Group 2017 SGR 219., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

A parallel Monte Carlo method for solving electromagnetic scattering in clusters of dielectric objects

  • López Menchón, Héctor|||0000-0001-5776-1423
  • Úbeda Farré, Eduard|||0000-0001-6759-0445
  • Heldring, Alexander|||0000-0003-2011-2096
  • Rius Casals, Juan Manuel|||0000-0003-0606-5422
In this work, we develop a novel Monte Carlo method for solving the electromagnetic scattering problem for clusters of photonic particles. The method is based on a formal solution of the scattering problem as a modified Born series whose coefficients are found by a conformal transformation. The terms of the Born series are approximated by sampling random elements of its matrix representation, computed by the Method of Moments. Unlike other techniques like the Fast Multiple Method, this Monte Carlo method does not require communication between processors, which makes it suitable for large parallel executions., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019- 107885GB-C31 / AEI / 10.13039/501100011033, PID2020-113832RB-C21 / AEI / 10.13039/501100011033 and TEC2017-84817-C2-2-R / AEI / 10.13039/501100011033 and the Unidad de Excelencia Maria de Maeztu MDM- 2016-0600/AEI/10.13039/501100011033, which is financed by the Agencia Estatal de Investigación, Spain, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Proposal for the deployment of an augmented reality tool for construction safety inspection

  • Ramos Hurtado, Jorge
  • Muñoz La Rivera, Felipe
  • Mora Serrano, Javier|||0000-0001-7142-2559
  • Deraemaeker, Arnaud
  • Valero Moreno, José Ignacio
The construction site is a hazardous place. The dynamic, complex interaction between workers, machinery, and the environment leads to dangerous risks. In response to such risks, the goal is to fulfill the zero accidents philosophy, which requires the development of safety skills among workers and the provision of tools for risk prevention. In pursuit of that vision, this work studies collective protective equipment (CPE). Traditional methodologies propose visual inspections using checklists, the effectiveness of which depends on the quality of the inspection by the safety advisor (SA). This paper analyses the traditional process of safety inspections in building projects: the traditional methods, main pain points, and bottlenecks are identified, along with the key performance indicators (KPIs) needed to complete these processes correctly. Because of this, a methodology that digitises the CPE inspection process is proposed. Augmented reality (AR) is used as a 3D viewer with an intuitive interface for the SA, and, accordingly, functional requirements are detailed and different information layers and user interfaces for AR applications are proposed. In addition, the workflow and KPIs are shown. To demonstrate the feasibility of the proposal, a proof of concept is developed and evaluated. The relevance of this work lies in providing background for the use of AR in safety inspection processes on construction sites and in offering methodological recommendations for the development and evaluation of these applications., This work has been supported by the Ministry of Science, Innovation and Universities of Spain (MICIU) through the BIMIoTICa project (RTC-2017-6454-7) and by the CONICYT for its economic support to Felipe Muñoz, beneficiary of a pre-doctoral grant (CONICYT—PCHA/International Doctorate/2019-72200306). The authors also acknowledge the financial support from the Spanish Ministry of Economy and Competitiveness, through the “Severo Ochoa Centre of Excellence (2019–2023) under the grant CEX2018-000797-S funded by MCIN/AEI/10.13039/501100011033”., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Improvements in randomized matrix compression methods for numerical analysis of antennas and scatterers

  • López Menchón, Héctor
  • Heldring, Alexander
  • Úbeda Farré, Eduard
  • Rius Casals, Juan Manuel
We propose a randomized Pseudo Skeleton (or CUR) Approximation method to compress the H-matrices of linear systems that arise in the discretization of integral equations in electromagnetic scattering. This method is highly parellelizable and well suited for fine-granularity architectures as GPUs. As the Adaptive Approximation Method (ACA), the method is purely algebraic. The method is tested with standard cases to assess its quality and efficiency, This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019-107885GBC31 / AEI / 10.13039/501100011033, PID2020-113832RBC21 / AEI / 10.13039/501100011033 and PID-2020-118410RB-C21 / AEI / 10.13039/501100011033, PDC2022-133091-I00 / AEI / 10.13039/501100011033, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

High-sensitivity microwave resonator sensor for aqueous glucose detection using field-concentrating elements

  • Ataa Allah, Fatima
  • Ataa-Allah, Houda
  • El mrabet, Otman
  • Aznabet, Mariem
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
In this article, we present a highly sensitive microwave sensor for determining the concentration of aqueous glucose solutions in the microwave regime. The proposed sensor is based on a single split-ring resonator (SRR) printed on a Rogers RO3003 substrate and operates at 2.9 GHz. The sensitivity of this sensor is enhanced by using a narrow gap of approximately 100 µm, which increases the capacitance of the SRR and, more importantly, produces a localized field enhancement within the gap region. Moreover, the proposed design operates with only 2 µL of sample, a notable improvement over sensors that typically require larger liquid volumes. Both the simulation and measurement results showed a clear linear shift in the resonance frequency over a concentration range of 0–400 mg/dL, with the ability to detect minimal concentration variations as small as 50 mg/dL. These results confirm the effectiveness of the sensor for noninvasive glucose detection and represent a significant advancement in the field of microwave sensing., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de Investigación, Spain, under Grant CICYT PID2019-107885GB- C31, PID2022-136869NB-C31 MICIU / AEI / 10.13039 / 501100011033/ FEDER, UE, and Grant Prueba de Concepto PDC2022-133091-I00; and in part by the Next Generation EU. Additionally, this work is supported by the CNRST as part of the ”PhD-Associate Scholarship– PASS” Program., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Magnetòmetre de bombeig òptic amb guia magnètica d’elevada resolució espacial per a detectar gotes magnètiques en un canal microfluídic

  • Jofre Cruanyes, Marc
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Els sensors quàntics proporcionen una sensitivitat sense precedents per a detectar camps magnètics, fet que els permet ampliar l’abast habitual d’aplicacions i de contextos d’ús de la magnetometria. Moltes aplicacions també requereixen mesures magnètiques d’elevada resolució espacial en recerca biomèdica, monitoratge ambiental i producció industrial. En aquest aspecte, els magnetòmetres de bombeig òptic (OPM) són candidats destacats, però tenen limitacions a l’escala de les partícules magnètiques micromètriques, per exemple, gotes magnètiques. Per tractar aquesta limitació, aquí estudiem els efectes d’afegir una guia magnètica que fa de pont entre micròmetres i mil·límetres a un OPM en miniatura. Aquest instrument s’utilitza per a detectar gotes magnètiques de Fe3O4 a un flux de fins a 25 gotes per segon en un canal microfluídic. La resolució espacial calculada és de 300 µm i la relació senyal-soroll és més gran que 15 dB per a les diferents mides de gota magnètica estudiades., Aquest estudi ha estat finançat per l’ajuda DR-2014-2022/56-30157-2021-2A de la Generalitat de Catalunya i les ajudes ICYT PID2019-107885GB-C31 i Prueba de Concepto PDC2022-133091-I00 del Ministeri de Ciència, Innovació i Universitats (Espanya)., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

MIMO radar antenna with sectorial human torso illumination for an in-cabin breathing detection system

  • López Montero, María José
  • Palacios Arias, César Augusto
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
The vital sign measurement systems inside vehicles have taken great or impulse in recent years, and the technologies that have been most welcomed are based on wireless measurements that do not interrupt driving and are imperceptible to the driver. There are disorders in breathing patterns, which include the movement of different regions of the human thorax mainly. In this sense, the objective of this paper is to determine the dimensions of a lens-based antenna system and the pointing angles of the radiation main lobe of the six antenna-elements to measure the elongation of six regions of the human torso and determine breathing patterns. The pointing angle is controlled by the position of the antenna behind the lens, and the beamwidth of the lobe depends on the directivity achieved by the antenna. An electronic system to simulate torso elongation is also presented to calibrate and test the sensitivity of the system., This work was supported by the Spanish “Comisión Interministerial de Ciencia y Tecnologia” (CICYT) under projects PID2019-107885GB-C31 and MDM2016-O6OO; Catalan Research Group 2017 SGR 219; and ”Secretaría Nacional de Educación Superior, Ciencia, Tecnología e Innovación” (SENESCYT) from the Ecuadorian government., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

UWB microwave functional brain activity extraction for Parkinson's disease monitoring

  • Akazzim, Youness
  • Palacios Arias, César Augusto
  • Jofre Cruanyes, Marc
  • El Mrabet, Otman
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Microwaves have proven their imaging capabilities to visualize the body composition for medical applications, thanks to their penetration inside biological structures. In this context, this article presents a novel methodology that aims to extract not just the internal morphology, but also the brain’s functional activity using the UWB pulse amplitude modulation (PAM) technique to have simultaneously functional monitoring and imaging capability and apply it to monitor the Parkinson’s disease (PD). The radio-frequency system is composed of two orthogonal sets of double UWB probes operating in the frequency range of 0.5–1.5 GHz. An experimental setup has been devised that avoids complex in vivo testing, albeit allows a system proof-of-concept validation. A bio-tag (BT) consisting of an optically modulated photodiode is used to emulate local medium changes associated with cell activity. The proposed system is used to first extract the modeled brain action potential (AP) to validate the performance of the BT and then to monitor the PD based on the beta frequency band character within basal ganglia–thalamocortical (BGTC) which is a key marker for the PD. The results show a good capability of locating and differentiating the signals generated within the phantom by the BT, alternatively emulating the healthy and PD’s state, based on the frequency. The obtained results of the functional monitoring technique on distinguishing the healthy from nonhealthy brain model activity, as well as in the phantom mimicking the average proprieties of a human head, will serve as a basis for detecting functional diseases in the future., This work was supported in part by Comision Interministerial de Ciencia y Tecnologia (CICYT) PID2019-107885GB-C31, PID2022-136869NB-C31, Catalan Research Group 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR) under Grant 2021 FISDU 00195; in part by the PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya; and in part by the Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Acceleration of Born series by change of variables

  • López Menchón, Héctor
  • Rius Casals, Juan Manuel
  • Heldring, Alexander
  • Úbeda Farré, Eduard
In this work, we propose a method to enhance the convergence of the Born series. The Born series is widely used in scattering theory, but its convergence is only guaranteed under certain restrictive conditions which limit the cases where this formulation can be applied. The proposed method, based on modifying the singularities of the resolvent operator by a change of variables, accelerates the convergence of the series or even achieves convergence in otherwise divergent cases. Due to its low computational cost and ease of implementation, the method preserves the advantages of the Born series while it extends its range of application. It can also be applied to a variety of methods relying on the same mathematical principles as the Born series. Numerical examples are provided to show that a significant improvement can be achieved with simple techniques and with a limited knowledge about the operator spectrum., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects TEC2016-78028-C3-1-P, MDM2016-0600, TEC2017-83343-C4-2-R, TEC2017-84817-C2-2-R, PID 2019-107885GB-C31 and Catalan Research Group 2017 SGR 219; and by Secretary of Universities and Research of the Ministry of Business and Knowledge of the Generalitat of Catalonia and European Social Fund under scholarship 2019 FI B00788., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

A GPU parallel randomized CUR compression method for the Method of Moments

  • López Menchón, Héctor
  • Heldring, Alexander
  • Úbeda Farré, Eduard
  • Rius Casals, Juan Manuel
In this work, we propose a GPU parallel implementation of the randomized CUR (or Pseudo Skeleton) Approximation to compress the -matrices of linear systems that arise in the discretization of integral equations modeling electromagnetic scattering problems. This compression method is highly parallelizable, in contrast with other similar methods such as the Adaptive Cross Approximation. It involves dense linear algebra computations that can be efficiently implemented on a GPU device. Besides, a stochastic convergence criterion is introduced to minimize the communication between the host and the device. Testing the code with standard cases shows the efficiency and accuracy of the method., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019- 107885GB-C31 / AEI / 10.13039/501100011033, PID2020-113832RB-C21 / AEI / 10.13039/501100011033 and PID-2020-118410RB- C21 / AEI / 10.13039/501100011033, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Simple randomized strategies for low-rank matrix compression

  • López Menchón, Héctor
  • Molina Burgués, Robert
  • Heldring, Alexander
  • Úbeda Farré, Eduard
  • Rius Casals, Juan Manuel
We propose a randomized Pseudo Skeleton (or CUR) approximation method to compress the H-matrices of linear systems that arise in the discretization of integral equations in electromagnetic scattering. This method is essentially the Matrix Decomposition Algorithm (MDA) of Michielssen and Boag (1994) with equivalent basis and testing functions equal to a random subset of the original ones. It is highly parellelizable and well suited for fine-granularity architectures as GPUs. As the Adaptive Cross Approximation (ACA), CUR is purely algebraic. The method is tested with standard cases to assess its quality and efficiency., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019-107885GBC31 / AEI / 10.13039/501100011033, PID2022-136869NBC31 / AEI / 10.13039/501100011033, PID2020-113832RBC21 / AEI / 10.13039/501100011033 and PID-2020-118410RB-C21 / AEI / 10.13039/501100011033, PDC2022-133091-I00 / AEI / 10.13039/501100011033, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Short asymmetrical inductive dipole antenna for direct matching to high-Q chips

  • Ballesteros Sánchez, Christian
  • Vega Piña, Sara
  • Santos Blanco, M. Concepción
  • Jofre Roca, Lluís
A planar antenna structure based on a folded asymmetrical dipole is presented, whose geometrical parameters are seen to independently determine either the real or the imaginary parts of the complex radiation impedance. This unique feature allows very efficient and wide-band conjugate matching coupling to non-conventional RF sources of arbitrary internal impedance, i.e., small resistance with large and negative reactance. The antenna theoretical framework is developed and an optimized design to match a photodiode is manufactured and measured. The results show a fractional bandwidth of about 20% in the 28 GHz band., This work was supported by the Spanish Ministry of Economy thanks to the project PID2019-107885GB-C31, the Catalan Research Group 2017 SGR 219, and the Ministry of Education with pre-doctoral grant FPU17/05561 to the first author., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Lens based switched beam antenna for a 5G smart repeater

  • Romeu Robert, Jordi
  • Blanch Boris, Sebastián
  • Pradell i Cara, Lluís
  • Barlabe Dalmau, Antoni
  • Rius Casals, Juan Manuel
  • Albert Galí, Miquel
  • Jofre Roca, Lluís
  • Mazzucco, Christian
  • Flamini, Roberto
A 16 switched beam lens based antenna with a coverage area of ±30° in the horizontal plane and from 0 to -20° in the vertical plane has been built and tested. The intended use of the antenna is as part of a smart repeater servicing the coverage area of a 5G wireless communication system operating in the n258 band of the 5G Frequency Range 2, from 24.25 to 27.5 GHz. The antenna has been built using state-of-the-art materials and components in order to assess the performance of this antenna concept. The overall antenna losses including the feeding network are of the order of 8 dB and the realized gain in the 80% of the coverage area is above 11 dB., This work was funded in part by AEI: PID2019-107885GB-C31/AEI/10.13039/501100011033 and HUAWEI TECHNOLOGIES Italia S.r.l, Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Fast analysis and optimization of sparsely distributed partial modification problems

  • Fang, Xiaoxing
  • Heldring, Alexander
  • Rius Casals, Juan Manuel
  • Cao, Qunsheng
This article addresses the efficient numerical analysis of sparsely distributed small modifications in a large structure, that is, the sparsely distributed partial modification problem (SDPMP). A hierarchical matrix (H-matrix)-based fast direct solver is adopted to solve the SDPMP in a very short time for each new set of modifications. The main idea of this method is to reuse the parts of the compressed inverse matrix operator that do not change and only recompute the modified parts. In contrast with already existing algorithms designed to tackle a single localized modification, this new approach is still very fast for sparsely distributed small modifications, so it becomes a very attractive option to solve optimization problems efficiently, due to the very cheap analysis of the modified structure at each iteration of the optimization procedure. The efficiency of the solution of SDPMP is demonstrated for several cases involving passive and active metasurfaces and a reconfigurable antenna. As a practical example, a programmable metasurface reflector is optimized with particle swarm optimization to obtain a prescribed reflection pattern., This work was supported in part by the National Nature Science Foundation of China under Grant 61871219; in part by the China Scholarship Council under Grant 201906830042; in part by the Startup Foundation for Introducing Talent of the Nanjing University of Information Science and Technology (NUIST) under Grant 2022r079; in part by the Ministerio de Ciencia e Innovacion (MICINN) under Project PID2019- 107885GB-C31/AEI/10.13039/501100011033, Project PID2020-113832RBC21/AEI/10.13039/501100011033, and Project TEC2017-84817-C2-2-R/AEI/ 10.13039/501100011033; and in part by the Unidad de Excelencia Maria de Maeztu, which is financed by the Agencia Estatal de Investigación, Spain, under Grant MDM-2016-0600/AEI/10.13039/501100011033; and in part by the Catalan Agency for Management of University and Research Grants (AGAUR) under Research Group under Grant 2017 SGR 219., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Enhanced robustness of a bridge-type Rf-Mems switch for enabling applications in 5G and 6G communicationsr

  • Casals Terré, Jasmina
  • Pradell i Cara, Lluís
  • Heredia, Julio
  • Giacomozzi, Flavio
  • Iannacci, Jacopo
  • Contreras Lizárraga, Adrián
  • Ribó Pal, Miquel
In this paper, new suspended-membrane double-ohmic-contact RF-MEMS switch configurations are proposed. Double-diagonal (DDG) beam suspensions, with either two or three anchoring points, are designed and optimized to minimize membrane deformation due to residual fabrication stresses, thus exhibiting smaller mechanical deformation and a higher stiffness with more release force than previously designed single diagonal beam suspensions. The two-anchor DDGs are designed in two different orientations, in-line and 90¿ -rotated. The membrane may include a window to minimize the coupling to the lower electrode. The devices are integrated in a coplanar-waveguide transmission structure and fabricated using an eight-mask surface-micro-machining process on high-resistivity silicon, with dielectric-free actuation electrodes, and including glass protective caps. The RF-MEMS switch behavior is assessed from measurements of the device S parameters in ON and OFF states. The fabricated devices feature a measured pull-in voltage of 76.5 V/60 V for the windowed/not-windowed two-anchor DDG membranes, and 54 V/49.5 V for the windowed/notwindowed three-anchor DDG membranes, with a good agreement with mechanical 3D simulations. The measured ON-state insertion loss is better than 0.7 dB/0.8 dB and the isolation in the OFF state is better than 40 dB/31 dB up to 20 GHz for the in-line/90¿ -rotated devices, also in good agreement with 2.5D electromagnetic simulations, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Magnetoelectric dipole antenna framework supporting orbital angular momentum modes

  • Jofre Cruanyes, Marc
  • Akazzim, Youness
  • Blanch Boris, Sebastián
  • Romeu Robert, Jordi
  • Cetiner, Bedri Artug
  • Jofre Roca, Lluís
The ability to utilize resources to meet the need of growing diversity of communication services and user behavior marks the future of cognitive wireless communication systems. Cognitive wireless technologies for vehicular communications, in combination with Orbital Angular Momentum (OAM) modes aim at extending Non-Line-Of-Sight (NLOS) short-distance communications for smart mobility. In this regard, OAM antenna frameworks need to be developed to support these technologies. In this work, we describe a magnetoelectric dipole antenna framework supporting OAM modes. The framework is derived from moment tensors of specific vector spherical harmonic functions synthesized from dipoles. The antenna framework is discussed in terms of OAM generation, and it is validated numerically and experimentally for l = 1 OAM mode, achieving more than 500MHz operation bandwidth at the frequency of operation of 3.5GHz. Also, for l = 1 OAM mode, the null aligns precisely with the anticipated dimensions numerically computed., This work was financially supported by PDR-2014-2022/56-30157-2021-2A, 2021 SGR 01415 Q0818003F and Metropolis PLEC2021-007609 grants of the Generalitat de Catalunya and European Regional Development Fund (FEDER), by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31 and Prueba de Concepto PDC2022-133091-I00 grants of the Agencia Estatal de Investigación (Spain) and Next Generation EU., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Ultra-wideband narrow wall waveguide-to-microstrip transition using overlapped patches

  • Zhou, Ivan
  • Romeu Robert, Jordi
An ultrawideband rectangular waveguide to microstrip line transition operating at the whole LMDS and Ka band is presented. The transition is based on exciting three overlapped transversal patches that radiate into the narrow wall of the waveguide, making the design feasible to be used in ¿g/2 spaced phased arrays. Both top-side and bottom-side versions were designed and compared to show their differences. They were validated by means of a manufactured back-to-back (B2B) configuration, with a measured fractional bandwidth of 21.2% (top-side) and 23% (bottom-side). The maximum single transition measured insertion losses were 0.67 dB (top-side) and 0.85 dB (bottom-side) in the whole band of operation, This work was supported by the Spanish “Comision Interministerial de Ciencia y Tecnologia” (CICYT) under projects DI2020-043, Agencia Estatal de Investigación PID2019-107885GBC31/AEI/ 10.13039, and Catalan Research Group 2017 SGR 219., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Low-Profile UWB probe for precise time-domain functional imaging

  • Akazzim, Youness
  • El Mrabet, Otman
  • Jofre Roca, Lluís
In this paper a Double Ridge Waveguide (DRW) antenna fed by a microstrip line covering a frequency band from 0.5GHz to 2.5GHz is designed, fabricated, and measured, for functional microwave imaging. The proposed DRW antenna is used as the probe element in a collateral multi-static system to detect a cylindrical target located inside a human brain liquid medium. Also, an approach for the spatial reconstruction accuracy based on maximum time resolution is presented. Measured and simulated results are conducted and discussed., This work was financially supported by CICYT PID2019- 107885GB-C31, MDM2016-0600, and support grants for university departments and research units (FI-SDUR)(2021 FISDU 00195). This work was supported by the National Center for Scientific and Technological Research (CNRST) under grant number PPR2/2015/36., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Microwave monitoring of Parkinson disease using a realistic human head model

  • Akazzim, Youness
  • Gugliermino, Martina
  • Rodríguez Duarte, David Orlando
  • Tobón Vásquez, Jorge Alberto
  • Vipiana, Francesca
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Parkinson's disease (PD) is a widespread neurode-generative disorder characterized by the loss of dopaminergic neurons from the substantia nigra, causing bradykinesia, tremors, rigidity, and postural instability. In this paper, we present a differential microwave imaging study (MWI) for early-stage PD monitoring that uses the dielectric properties of the basal ganglia, particularly the thalamus. The simulations are carried out using two scenarios: one is based on studying the sensitivity of a realistic human head model. The other is the study of differential microwave imaging to monitor the PD based on the dopamine level changes in the basal ganglia. The MWI system contains 24 printed flexible antennas with a custom-made matching medium covering the head model. The obtained results demonstrate that small variations in dielectric properties within the human head, in particular the thalamus, can be detected, which can be used to monitor Parkinson's disease in a very early stage., This work was financially supported in part by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31, 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR)(2021 FISDU 00195), PDR-2014-2022/56-30157-2021-2 A grant of the Generalitat de Catalunya, and Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovacion y Universidades (Spain). This work was supported in part by the project PON Research and Innovation “Microwave Imaging and Detection powered by Artificial Intelligence for Medical and Industrial Applications (DM 1062/21)”, funded by MUR. It was carried out partially within the Agritech National Research Center, funded by the Next-Generation EU (PNRR, Missione 4, Componente 2, Investimento 1.4, D.D. 1032 17/06/2022, CN00000022., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Optical beam steering network with multiband capability

  • Vega, Sara
  • Nuño Gómez, Daniel-Juan
  • Santos Blanco, M. Concepción
A multiwavelength (MW) optical true time delay Network (OTTDN) to feed a phased array antenna (PAA) is presented. Beam steering capabilities can be demonstrated when applying MW tuning. A Dual Electrode Mach Zehnder Modulator (DE-MZM) as radio frequency (RF) external modulating stage allows to tune the operative band avoiding severe Chromatic Dispersion (CD) fading to obtain a flattened response. A working example simulation of a 4 elements array at 8 GHz shows the RF multiband spectral flat response potential of the technique, as well as the network conditions needed for beam steering with free-lobe operation., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects TEC2016-78028-C3-1- P, PID 2019-107885GB-C31, MDM2016-0600, and Catalan Research Group 2017 SGR 219., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Mie scattering with 3D angular spectrum method

  • Lamberg, Joel
  • Zarrinkhat, Faezeh
  • Tamminen, Aleksi
  • Ala-Laurinaho, Juha
  • Rius Casals, Juan Manuel
  • Romeu Robert, Jordi
  • Khaled, Elsayed E. M.
  • Taylor, Zachary
Mie theory is a powerful method to model electromagnetic scattering from a multilayered sphere. Usually, the incident beam is expanded to its vector spherical harmonic representation defined by beam shape coefficients, and the multilayer sphere scattering is obtained by the T-matrix method. However, obtaining the beam shape coefficients for arbitrarily shaped incident beams has limitations on source locations and requires different methods when the incident beam is defined inside or outside the computational domain or at the scatterer surface. We propose a 3D angular spectrum method for defining beam shape coefficients from arbitrary source field distributions. This method enables the placement of the sources freely within the computational domain without singularities, allowing flexibility in beam design. We demonstrate incident field synthesis and spherical scattering by comparing morphology-dependent resonances to known values, achieving excellent matching and high accuracy. The proposed method has significant benefits for optical systems and inverse beam design. It allows for the analysis of electromagnetic forward/backward propagation between optical elements and spherical targets using a single method. It is also valuable for optical force beam design and analysis., Agencia Estatal de Investigación (PID2019-107885GB282 C31/AEI/10.13039, PRE2018-084326); Assessment of the Graft 281 Rejection Using Millimeter Waves; Academy of Finland (327640)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Magnetoelectric dipole antenna extending NLOS short-distance vehicular communication with orbital angular momentum modes

  • Jofre Cruanyes, Marc
  • Akazzim, Youness
  • Towfiq, Asaduzzaman
  • Cetiner, Bedri Artug
  • Blanch Boris, Sebastián
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
The ability to utilize resources to meet the need of growing diversity in services and user behavior marks the future of cognitive wireless communication systems. Cognitive wireless technologies for vehicular communications, in combination with Orbital Angular Momentum (OAM) modes aim at extending direct Non-Line-Of-Sight (NLOS) short-distance communications for smart mobility. In this regard, OAM antennas need to be developed to support these technologies. To this end, here we describe a compact antenna supporting the first OAM modes. Also, the antenna properties are discussed and are numerically and experimentally validated for OAM modes of l=±1 . Particularly, for the considered OAM modes, the antenna achieves more than 500 MHz operation bandwidth at the frequency of operation of 3.5 GHz. Also, for l=±1 OAM modes, the null beamwidth aligns precisely with the anticipated dimensions theoretically computed., This work was financially supported by PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya and by CICYT PID2019-107885GB-C31, PID2022-136869NB-C31 and Prueba de Concepto PDC2022-133091-I00 and Metropolis PLEC2021-007609 grants of the Ministerio de Ciencia, Inno-vación y Universidades (Spain)., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Vector spherical harmonic analysis and experimental validation of spherical shells illuminated with broadband, millimeter wave Gaussian beams: applications to corneal sensing

  • Zarrinkhat, Faezeh
  • Lamberg, Joel
  • Tamminen, Aleksi
  • Baggio, Mariangela
  • Nefedova, Irina
  • Ala-Laurinaho, Juha
  • Khaled, Elsayed E. M.
  • Romeu Robert, Jordi
  • Rius Casals, Juan Manuel
  • Taylor, Zachary
Coupling to longitudinal modes of thin spherical shells, under Gaussian-beam illumination, was explored with a theoretical method based on Fourier-optics analysis and vector spherical harmonics and was scrutinized with an experimental setup. For the theory part, the illumination frequency band was fixed between 100–600 GHz and the outer spherical shell radius of curvature and thickness are 7.5 mm and 0.5 mm, respectively. The shell material was either the lossless cornea or an aqueous effective media representing the cornea. Six different beam-target strategies were introduced being potential candidates for maximum coupling. Two dispersion-tuned beam ensembles with strongly frequency-dependent phase center location have been created with a fixed incident beam 1/e radius and radius of curvature called forward strategies. These computations of different alignments were continued with four beam ensembles of frequency-invariant phase center, constructed from fits to experimental data, oriented at four different axial locations with respect to the spherical shell center of curvature, they are called reverse strategies. Coupling efficiency for all strategies was calculated for different targets including perfect electrical conductor (PEC) sphere, PEC core covered by a cornea loss-free layer and cornea. All scattering strategies contrasted to scattering from equivalent planar targets as a reference with maximum coupling. The results show that, under an ideal calibration, forward strategies are a closer approximation to the plane-wave condition for the cornea. An experimental setup was assembled to explore the simulation approach in a frequency range between 220 GHz to 330 GHz. Two different quartz samples with permittivity of 4.1 were mounted on a water core, acting for a cornea. The first and second quartz radius and thickness were 7.5 mm and 0.5 mm and 8 mm and 1 mm, respectively. An adequate agreement between theory and experiment was confirmed. A particle optimisation swarm algorithm was applied to extract the thickness and permittivity of quartz from the measured back-scattered field for reverse strategies., Funding. Agencia Estatal de Investigación (PID2019-107885GB-C31/AEI/10.13039, PRE2018-084326); Academy of Finland (327640)., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Coherent UD-WDM RoF Fronthaul network with D-EML transmitter and phase-noise robust receiver

  • Masanas Jiménez, Miquel
  • Tabares Giraldo, Jeison
  • Prat Gomà, Josep Joan
This work proposes and tests a simplified coherent uplink architecture for ultra-dense coherent analog mobile Fronthaul with phase noise cancellation based on single sideband modulation of a dual-EML. Results show optical channel spacings of only 1.5 GHz and error-free signal recovery with Δν Tb = 1.2% and 3% with reaching power as low as −46dBm for 100 Mbit/s and −38 dBm for 1 Gbit/s using QPSK modulation., This work was supported by the Spanish Comisión Interministerial de Ciencia y Tecnología (CICYT) Project Versatile Coherent Dual Optical Network (VERSONET) under Grant RTI2018-097051 and in part by the Grant “Proyectos de I+D+i” under Grant PID2019-107885GB- C31., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Supervised machine learning assisted driving stress monitoring MIMO radar system

  • López Montero, María José
  • Palacios Arias, César Augusto
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Factors such as road traffic, challenging ambient temperature conditions, and extended periods of driving have detrimental effects on the physical and mental well-being of a driver. These factors can alter the stress levels, thereby diminishing his or her capacity to make effective decisions when faced with hazardous situations on the road. In this regard, this study presents a novel approach utilizing a multiple-input multiple-output (MIMO) radar system to accurately assess driver stress levels by measuring both physiological signals and driving behavior. The proposed method, assisted by a machine learning technique, provides comprehensive insights to classify the stress level of a driver into three states: drowsiness, awakeness, and anxiety. The MIMO radar system captures the elongation distance and velocity of six specific regions of the frontal torso of the driver in an advanced driving simulator based on virtual reality. This allows for the extraction of vital physiological parameters such as heart rate, respiratory rhythm, and breathing patterns over time, as well as the identification of changes in driving style determined by variations in their relative position in the seat and control of the steering wheel. Then, a fully connected neural network (FCNN) model is trained with the acquired data, and its performance is evaluated with volunteers submitted to different driving situations that induce stress in the driver. The findings show an accuracy in drowsiness detection of 90%, awakeness of 96% and anxiety of 85%., This work was supported by the Spanish “Comision Interministerial de Ciencia y Tecnologia” (CICYT) under projects PID2019-107885GB-C31, PID2022-136869NB-C31 and MDM2016-O6OO; Catalan Research Group 2017 SGR 219; and ”Secretaría Nacional de Educación Superior, Ciencia, Tecnología e Innovación” (SENESCYT) from the Ecuadorian government., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Solving electromagnetic scattering in dielectric bodies by Monte Carlo sampling

  • López Menchón, Héctor
  • Rius Casals, Juan Manuel
  • Úbeda Farré, Eduard
  • Heldring, Alexander
In this work, we propose Monte Carlo sampling as a technique to avoid communication overhead in the numerical solution of complex electromagnetic scattering problems. The method is based on statistically sampling a formal representation of the solution of the scattering problem, based on a modified Born series. The sampling process can be independently carried out in different processors with no need for communication between them. This lack of communication makes the algorithm suitable for massively parallel computational environments., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019-107885GB-C31 / AEI / 10.13039/501100011033, PID2020-113832RB- C21 / AEI / 10.13039/501100011033 and TEC2017- 84817-C2-2-R / AEI / 10.13039/501100011033 and the Unidad de Excelencia Maria de Maeztu MDM-2016- 0600/AEI/10.13039/501100011033, which is financed by the Agencia Estatal de Investigaci ´on, Spain, and Catalan Research Group 2017 SGR 219, and Ag`encia de Gesti ´o d’Ajuts Uni- versitaris i de Recerca with grant 2021 FI B2 00096., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Rayleigh backscattering rejection in single-laser homodyne transceiver for UD-WDM using λ-Shifting

  • Masanas Jiménez, Miquel
  • Santos Blanco, M. Concepción
  • Tabares Giraldo, Jeison
  • Polo Querol, Víctor
  • Prat Gomà, Josep Joan
With the aim of using a single laser per transceiver in single fiber splitter-based passive optical networks (PON) with coherent homodyne receivers, we apply wavelength shifting in an ultra-dense wavelength division multiplexing (UD-WDM) scheme. The studied architecture is based on a dual-parallel Mach-Zehnder Modulator (DP-MZM) operating in carrier-suppressed single-sideband (CS-SSB). In this configuration, a single laser feeds both the coherent homodyne receiver, and the transmitter, simplifying the wavelength management in the PON. The modulator carries out both data modulation and wavelength shifting. In this study, a bit rate of 4 Gb/s in QPSK is used to test several roll-off factors and channel spacing configurations. The results show that power budget gains of 18 dB are achievable with a channel spacing equal to only the symbol rate., This work was supported in part by the Spanish CICYT Project VERSONET under Grant RTI2018-097051, in part by Proyectos de I+D+i under Grant PID2019-107885GB-C31, and in part by María de Maeztu under Grant MDM2016-0600., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Characterization of THz radiation by collimated wavefront aperture raster scanning

  • Nuño Gómez, Daniel-Juan
  • Santos Blanco, M. Concepción
  • Gomez Diaz, J. Sebastian
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
We present measurements for characterization of the beam profile and polarization pattern of lens-coupled photoconductive antennas (PCAs) at THz frequencies using a setup with antennas at fixed positions and a movable aperture placed in between collimating THz lenses. The measured beam patterns for co-polar and cross-polar components reveal the expected Airy disc and quadrupole behavior, respectively. The temporal evolution of the polarization in the directions of maximum cross-polar component follows a single-cycle circle with opposite handedness at each side of the antennas line-of-sight (LOS). Results are consistent with those obtained with fiber-coupled movable antennas, while enjoying the simplicity of a free-space laser-PCA feed which does not require painstaking laser realignment for each beam direction measure., This work was partly funded by the Ministerio de Economía y Competitividad under projects TEC2016-78028-C3-1-P, PID 2019-107885GB-C31 and MDM2016-0600, and Catalan Research Group 2017 SGR 219., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

M-Port rotationally symmetric antennas for advanced MIMO applications

  • Aldana Alonso, Rubén
  • Molins Benlliure, Jaime
  • Akazzim, Youness
  • Llanga Vargas, Anibal
  • Jofre Cruanyes, Marc
  • Cabedo Fabrés, Marta
  • Antonino Daviu, Eva
  • Romeu Robert, Jordi
  • Ferrando Bataller, Miguel
  • Jofre Roca, Lluís
Multiple-input multiple-output (MIMO) technology has emerged as a highly promising solution for wireless communication, offering an opportunity to overcome the limitations of traffic capacity in high-speed broadband wireless network access. By utilizing multiple antennas at both the transmitting and receiving Sub-6GHz ends, the MIMO system enhances the efficiency and performance of wireless communication systems [1]. This work presents a comparison of the performance of two families of M-Rotationally Symmetrical MIMO antenna design approaches one based on the Magneto Electric (ME) dipole antenna and a second one based on the Circular Cavity principle intended for their use into advanced MIMO applications like Orthogonal Angular Momentum (OAM) and high capacity channels. A comparison of the relevant performance parameters in terms of frequency bandwidth (both input impedance 𝑺𝒊𝒊 and inter-port isolation 𝑺𝒊j) and radiation pattern are presented for the two Sub-6GHz prototypes., This work was financially supported by PDR-20142022/56-30157-2021-2A grant of the Generalitat de Catalunya and by CICYT PID2019-107885GB-C31, PID2019107885GB-C32, PID2022-136869NB-C31, PID2022136869NB-C33, and Prueba de Concepto PDC2022, Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Efficient analysis of thick curved metal sheets

  • Úbeda Farré, Eduard
  • Rius Casals, Juan Manuel
The scattering analysis of perfectly conducting plates with the method-of-moment discretization of the Electric-Field Integral Equation has been traditionally carried out according to the thin-sheet approximation, which neglects the current contributions over the plate rims. The plate is then modelled as an open surface and handles a restricted number of unknowns as compared with the canonical modelling as a closed object. The thin-sheet approximation, although used in many practical applications, becomes inaccurate for thick enough plates or plates under plane wave incidence at grazing angles. Recently, a thick-plate approach has been presented to address the time-efficient and accurate scattering analysis of thick plates. This scheme exploits the symmetry properties of fields and currents thereby giving rise to two uncoupled problems with roughly half the number of unknowns of the original problem. In this paper, we extend this thick-plate scheme to the efficient scattering analysis of thick curved sheets., This work was supported by FEDER and the "Spanish Plan Estatal de Investigación Científica y Técnica y de Innovación", under projects: TEC2017-84817-C2-2-R/ AEI/10.13039/501100011033, TEC2016-78028-C3-1-P/AEI/10.13039/501100011033, PID2019-107885GB-C31/AEI/10.13039/501100011033 and the Unidad de Excelencia Maria de Maeztu MDM-2016-0600/AEI/10.13039/501100011033, which is financed by the Agencia Estatal de Investigación, Spain, and Catalan Research Group 2017 SGR 219., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Optically pumped magnetometer with high spatial resolution magnetic guide for the detection of magnetic droplets in a microfluidic channel

  • Jofre Cruanyes, Marc
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Quantum sensors provide unprecedented magnetic field detection sensitivities, enabling these to extend the common magnetometry range of applications and environments of operation. In this framework, many applications also require high spatial resolution magnetic measurements for biomedical research, environmental monitoring and industrial production. In this regard, optically pumped magnetometers (OPMs) are considered as prominent candidates, but are impaired in size with micrometer scale magnetic particles, e.g. magnetic droplets. In order to address this limitation, here we study the effects of adding a micrometer-to-millimeter magnetic guide to a miniature OPM. This device is applied to detect Fe3O4 magnetic droplets flowing at rates up to 25 drop.¿s-1 in a microfluidic channel. The computed spatial resolution is 300¿µm and the measured signal-to-noise ratio is larger than 15¿dB for the different sizes of considered magnetic droplets., This work was financially supported by PDR-2014-2022/56-30157-2021-2A grant of the Generalitat de Catalunya and by CICYT PID2019-107885GB-C31 and Prueba de Concepto PDC2022-133091-I00 grants of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Preliminary phantom-based dynamic calibration techniques assessment for microwave colonoscopy systems

  • Garrido Atienza, Alejandra
  • Dghoughi, Walid
  • Romeu Robert, Jordi
  • Guardiola Garcia, Marta
Early detection and resection of colon polyp is the best way to reduce colorectal cancer (CRC) mortality. The current method for early detection is colonoscopy, which has a limited field of view, and its efficacy is highly dependant on the endoscopist's experience and colon preparation. This work presents a device for combining microwave imaging with optical colonoscopy. The challenges of this new microwave imaging system are presented, such as the unknown distance to the colon mucosa, which leads to undesired scattered fields and, the antenna size limitations. Four dynamic calibration techniques are proposed to remove the effects of the undefined distance from the imaging region to colon mucosa. These calibration methods are based on averaging the colonoscopy trajectory frames and subtracting the calibration set from the current frame. The phantom preliminary results show that these calibration methods completely delete the undesired scatter., A.G. acknowledges the financial support from DIN2019- 010857, M.G., and W.D acknowledge the financial support from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 960251 and from the European Institute of Innovation and Technology (EIT). J.R. acknowledges the financial support from Agencia Estatal Investigacion PID2019-107885GB-C31/AEI/10.13039/., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Microstrip-fed 3D-printed H-sectorial horn phased array

  • Zhou, Ivan
  • Pradell i Cara, Lluís
  • López Villegas, José María
  • Vidal Martínez, Neus
  • Albert Gali, Miquel
  • Jofre Roca, Lluís
  • Romeu Robert, Jordi
A 3D-printed phased array consisting of four H-Sectorial horn antennas of 200 g weight with an ultra-wideband rectangular-waveguide-to-microstrip-line transition operating over the whole LMDS and K bands (24.25–29.5 GHz) is presented. The transition is based on exciting three overlapped transversal patches that radiate into the waveguide. The transition provides very low insertion losses, ranging from 0.30 dB to 0.67 dB over the whole band of operation (23.5–30.4 GHz). The measured fractional bandwidth of the phased array including the transition was 20.8% (24.75–30.3 GHz). The antenna was measured for six different scanning angles corresponding to six different progressive phases α, ranging from 0° to 140° at the central frequency band of operation of 26.5 GHz. The maximum gain was found in the broadside direction α = 0°, with 15.2 dB and efficiency η = 78.5%, while the minimum was found for α = 140°, with 13.7 dB and η = 91.2%., This work was supported by MINISTERIO DE CIENCIA, INNOVACIÓN Y UNIVERSIDADES: PID2019-107885GB-C31/AEI/10.13039/501100011033 and DI-2020., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Microwave imaging for Parkinson’s disease detection: A phantom-based feasibility study using temperature-controlled dielectric variations

  • Cardinali, Leonardo
  • Rodríguez Duarte, David Orlando
  • Tobón Vásquez, Jorge Alberto
  • Vipiana, Francesca
  • Jofre Roca, Lluís
Parkinson’s disease (PD) is characterized by pathological changes in the substantia nigra, which in its early stages may manifest as structural and functional asymmetries between the two hemispheres. Microwave imaging has recently emerged as a promising non-invasive tool to detect subtle dielectric variations. In the context of Parkinson’s disease, such contrasts are expected to arise from the underlying physiological alterations in brain tissue, although their magnitude has not yet been fully characterized. In this work, we investigate the feasibility of differential microwave imaging, where detection is based on permittivity contrasts, through a controlled phantom study. A simple two-dimensional head phantom was constructed using a 3D-printed cylindrical container filled with water, incorporating a Teflon tube to represent the substantia nigra. The tube was filled with hot water, whose gradual cooling emulated small dielectric changes. Since the dielectric properties of water vary linearly with temperature over 0.5–3 GHz, we first validated this dependence through both numerical analysis and experimental measurements. Four antennas were then employed in a differential imaging configuration, with image reconstruction performed via the multi-frequency bi-focusing algorithm. The results show that the system can successfully detect a dielectric contrast corresponding to a temperature variation as small as 0.4 °C, equivalent to approximately 0.17% in relative permittivity. While the exact dielectric changes associated with PD remain to be determined, these results demonstrate that the proposed approach is sensitive to very small contrasts, supporting the potential of differential microwave imaging as a candidate tool for future investigations into Parkinson’s disease detection., This work was supported in part by the project “THERAD—Microwave Theranostics for Alzheimer’s Disease”, funded by Compagnia di San Paolo; in part by the project “INSIGHTFOOD—An innovative microwave sensing system for the evaluation and monitoring of food quality and safety”, funded by the Italian Ministry of Foreign Affairs and International Cooperation (MAECI, CUP E13C23000180005); in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de lnvestigacion, Spain, under Grant CICYT PID2019-107885GBC31, Grant PID2022-136869NB-C31, and Grant Prueba de Concepto PDC2022-133091-IO0; and in part by Next Generation EU. It was carried out partially within the Agritech National Research Center, funded by the European Union Next—Generation EU (Piano Nazionale di Ripresa e Resilienza (PNRR)—MISSIONE 4 COMPONENTE 2, INVESTIMENTO 1.4—D.D. 1032 17/06/2022, CN00000022)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Improving the accuracy of the adaptive cross approximation with a convergence criterion based on random sampling

  • Heldring, Alexander
  • Úbeda Farré, Eduard
  • Rius Casals, Juan Manuel
The accuracy of the Adaptive Cross Approximation (ACA) algorithm, a popular method for the compression of low rank matrix blocks in Method of Moment computations, is sometimes seriously compromised by unpredictable errors in the convergence criterion. This paper proposes an alternative criterion, based on global sampling of the error in the elements of the ACA compressed matrix. The sampling error depends on the size of the sample but also on the population distribution of the error, which makes it difficult to control the error independently of the underlying problem. However, as argued and demonstrated in the paper, the distribution of the error converges to the same unique probability distribution function for all low rank matrices. Complementing the sampling criterion with a simple mechanism to detect this convergence, we arrive at a criterion that controls the error irrespective of the underlying problem. As a practical example the RCS of a moderate size metallic ogive is computed to illustrate the merits of the proposed criterion. The proposed algorithm may also be useful in other methods that approximate low-rank matrices by interpolation of a reduced set of its elements., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects TEC2016-78028-C3-1-P, TEC2017-84817-C2-2-R, TEC2017-83343-C4-2-R, PID 2019-107885GBC31, MDM2016-0600, and Catalan Research Group 2017 SGR 219., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Automatic polyp detection using microwave endoscopy for colorectal cancer prevention and early detection: phantom validation

  • Garrido Atienza, Alejandra
  • Sont Colomer, Roberto
  • Dghoughi, Walid
  • Marcoval Martínez, Sergi
  • Romeu Robert, Jordi
  • Fernández-Esparrach, Glòria
  • Belda Reig, Ignasi
  • Guardiola Garcia, Marta
A system to integrate microwave imaging with optical colonoscopy is presented. The overarching goal is to improve the prevention and early diagnosis of one of the main health and economic burdens of an increasingly aging population, i.e., colorectal cancer. For a colonoscopy, the gold standard for colorectal cancer diagnosis, 22% of polyps are not detected, and the risk of cancer after a negative colonoscopy can be up to 7.9%. To remedy this, a microwave imaging system able to generate an alarm when a polyp is detected is designed, manufactured and validated with a colon phantom composed of tissue-mimicking oil-gelatin materials reproducing the anatomy and dielectric properties of a human colon with a polyp. The acquisition was performed by a miniaturized ring-shaped switched array of 16 antennas attachable at the tip of a conventional colonoscope. This has been conceived to satisfy endoscopy size restrictions, patient safety and intercompatibility with current clinical practice. A Modified Monofocusing imaging method preceded by a previous frame average subtraction as a calibration technique shows a perfect detection of a 10-mm polyp (100% sensitivity and specificity) in the eight analyzed trajectories. The phantom results demonstrate the feasibility of the system in future preclinical trials., The work of Alejandra Garrido was supported by DIN2019-010857. The work of Roberto Sont, Ignasi Belda, and Marta Guardiola was supported in part by the European Union’s Horizon 2020 Research and Innovation Programme under Grant 960251 and in part by the European Institute of Innovation and Technology (EIT). The work of Jordi Romeu was supported by PID2019-107885GB-C31/AEI/10.13039/501100011033., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Microwave resonant wireless sensor for enhanced particle detection in microfluidic channels

  • Ataa-Allah, Houda
  • Ataa Allah, Fatima
  • Palacios Arias, César Augusto
  • Aznabet, Mariem
  • El mrabet, Otman
  • Jofre Cruanyes, Marc
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
This paper presents a highly sensitive microwave sensor for bioparticle detection, designed around a ring-gap resonator integrated with a microfluidic channel. The sensor’s structure is optimized to enhance electric field confinement, improving its sensitivity to dielectric variations. Experimental validation using commercial microbeads as bioparticle models demonstrates clear resonance shifts, confirming the sensor’s capability for precise detection of particles up to 5 µm. These results highlight the potential of the proposed approach for realtime, label-free biosensing applications, offering a promising tool for biomedical diagnostics and analytical chemistry., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC2021-007609; in part by the Agencia Estatal de Investigación, Spain, under Grant CICYT PID2019- 107885GBC31, Grant PID2022-136869NB-C31, and Grant Prueba de Concepto PDC2022-133091-I00; and in part by the Next Generation EU. Additionally, this work is supported by the CNRST as part of the ”PhD-Associate Scholarship – PASS” Program., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

In-cabin MIMO radar system for human dysfunctional breathing detection

  • López Montero, María José
  • Palacios Arias, César Augusto
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
The integration of wireless sensors into the automotive industry is making vehicles increasingly safe and autonomous. At present, vehicles are equipped with external sensors that facilitate maneuverability and braking and internal sensors that detect presence, seat belt state, and occupant vital signs. Early detection of dysfunctional breathing patterns can reduce the risk of accidents caused by drowsiness or fatigue. In this regard, this work presents an MIMO FMCW Radar System able to distinguish dysfunctional breathing patterns from human torso motion. The torso has been divided into six regions, and the amplitude of the elongation and the frequency of motion of each region have been measured during breathing. An elongation map is then constructed in order to graphically show the dysfunctional breathing patterns. The signal processing includes a peak search algorithm to detect elongation amplitude and a bandpass frequency filter to minimize dc components, random driver motion, and vehicle vibration. A torso elongation emulator phantom has been assembled with materials of skin-like relative permittivity and dc motors for calibration and validation of basic breathing patterns. Finally, the signal of the system is compared with that of a commercial respiration belt, and then the system is tested by performing measurements on people. The MIMO radar system is able to measure, differentiate, and classify patterns associated with dysfunctional breathing such as hyperventilation syndrome and thoracic dominant breathing., This work was supported in part by the Spanish “Comision Interministerial de Ciencia y Tecnologia” (CICYT) under Project PID2019-107885GB-C31 and Project MDM2016- 0600, in part by the Catalan Research Group under Grant 2017 SGR 219, and in part by the “Secretaría Nacional de Educación Superior, Ciencia, Tecnología e Innovación” (SENESCYT) from the Ecuadorian Government, Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Microwave contactless current-sensing for live/dead differentiation of single bioparticles on a microfluidic platform, Detección de corriente sin contacto de microondas para diferenciación en vivo/muerto de biopartículas individuales en una plataforma microfluidic

  • Palacios Arias, César Augusto
  • Jofre Cruanyes, Marc
  • Jofre Cruanyes, Lluís
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
© 2023 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., The combination of microwave and microfluidic technologies enables the creation of efficient platforms to rapidly quantify live/dead bioparticles in industrial processes, biomedical research and environmental monitoring applications. In this regard, this work demonstrates the differentiation of single live/dead bioparticles with a microwave-microfluidic platform. The system is composed of a contactless current-sensing superheterodyne architecture with broadband frequency-operation bowtie electrodes. Furthermore, the 20mm × 20mm bowtie electrode has been designed and manufactured with a –10 dB frequency range, from 4GHz to 8GHz, and capable of confining the electric field in a micrometric volume. The gap of the bowtie geometry of the electrodes is adjusted to the dimensions of the 50 µm × 50 µm cross-section and 40mm long microfluidic channel. In particular, 10mL sample with 10 9 bacteria/mL flows through the microchannel at 19.8 µL/min, focused with elasto-inertial effect enhanced with 500 ppm of polyethylene oxide. Accordingly, from the signal captured by the electrodes, the energy variation of the applied electric field produced by the bioparticles is sensed by a current-based transimpedance amplifier. Here, the incorporation of the transimpedance amplifier in the measurement system improves the SNR by 4 dB. In addition, the superheterodyne transceiver has been optimized in terms of local oscillator power and bandwidth. Furthermore, the microfluidic system has been adjusted so that the balance of hydrodynamic forces confines bioparticles at the centerline of the microchannel within less than 5 µm. As a result, the system measures the cytoplasmic content of live and dead flowing bacteria with a difference of 6 dB and relative deviation of 3.2%., This work was financially supported by the PID2019- 107885GB-C31 and PDC2022-133091-I00 grants of the Agencia Estatal de Investigación (Spain), and the PDR-2014- 2022/56-30157-2021-2A grant from Generalitat de Catalunya (Spain). In addition, the authors are grateful for the support provided by the Formación de Personal Investigador (PID2019-107885GB-C31, PRE2020-093895) scholarship and the Beatriz Galindo (BGP18/00026) program of the Ministerio de Ciencia, Innovación y Universidades (Spain)., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

A multiparametric advection-diffusion reduced-order model for molecular transport in scaffolds for osteoinduction

  • Muixí Ballonga, Alba
  • Zlotnik, Sergio
  • Calvet Tordera, Pere
  • Español Pons, Montserrat
  • Lodoso Torrecilla, Irene
  • Ginebra Molins, Maria Pau
  • Díez, Pedro
  • García González, Alberto
The version of record is available online at: http://dx.doi.org/10.1007/s10237-022-01577-2, Scaffolds are microporous biocompatible structures that serve as material support for cells to proliferate, differentiate and form functional tissue. In particular, in the field of bone regeneration, insertion of scaffolds in a proper physiological environment is known to favour bone formation by releasing calcium ions, among others, triggering differentiation of mesenchymal cells into osteoblasts. Computational simulation of molecular distributions through scaffolds is a potential tool to study the scaffolds’ performance or optimal designs, to analyse their impact on cell differentiation, and also to move towards reduction in animal experimentation. Unfortunately, the required numerical models are often highly complex and computationally too costly to develop parametric studies. In this context, we propose a computational parametric reduced-order model to obtain the distribution of calcium ions in the interstitial fluid flowing through scaffolds, depending on several physical parameters. We use the well-known Proper Orthogonal Decomposition (POD) with two different variations: local POD and POD with quadratic approximations. Computations are performed using two realistic geometries based on a foamed and a 3D-printed scaffolds. The location of regions with high concentration of calcium in the numerical simulations is in fair agreement with regions of bone formation shown in experimental observations reported in the literature. Besides, reduced-order solutions accurately approximate the reference finite element solutions, with a significant decrease in the number of degrees of freedom, thus avoiding computationally expensive simulations, especially when performing a parametric analysis. The proposed reduced-order model is a competitive tool to assist the design of scaffolds in osteoinduction research., The authors acknowledge the financial support from the Ministerio de Ciencia e Innovación (MCIN/ AEI/10.13039/501100011033) through the grants PID2020-113463RBC32, PID2020-113463RB-C33, CEX2018-000797-S and PID2019-103892RB-I00, and the Generalitat de Catalunya for the Serra Hunter Fellowship of ME and the ICREA Academia Award of MPG., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Wireless sensing of concrete setting process

  • González López, Giselle
  • Romeu Robert, Jordi
  • Cairó, Ignasi
  • Segura Pérez, Ignacio
  • Ikumi Montserrat, Tai
  • Jofre Roca, Lluís
An RFID-based wireless system to measure the evolution of the setting process of cement-based materials is presented in this paper. The system consists of a wireless RFID temperature sensor that works embedded in concrete, and an external RFID reader that communicates with the embedded sensor to extract the temperature measurement conducted by the embedded sensor. Temperature time evolution is a well known proxy to monitor the setting process of concrete. The RFID sensor consisting of an UWB Bow Tie antenna with central frequency 868 MHz, matched to the EM4325 temperature chip through a T-match structure for embedded operation inside concrete is fully characterized. Results for measurements of the full set up conducted in a real-scenario are provided, This work was supported by the Spanish “Comision Interministerial de Ciencia y Tecnologia” (CICYT) under projects PID2019-107885GB-C31 / AEI / 10.13039/501100011033, MDM2016-0600, and by the “Unidad de Excelencia María de Maeztu”, 2017–2020., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Multi-element UWB probe optimization for medical microwave imaging

  • Akazzim, Youness
  • El Mrabet, Otman
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
The need for non-ionizing techniques for medical imaging applications has led to the use of microwave signals. Several systems have been introduced in recent years based on increasing the number of antennas and frequency bandwidth to obtain high resolution and good accuracy in locating objects. A novel microwave imaging system that reduces the number of required antennas for precise target location appropriate for medical applications is presented. The proposed system consists of four UWB extended gap ridge horn (EGRH) antennas covering the frequency band from 0.5 GHz to 1.5 GHz mounted on a cylindrical phantom that mimics the brain in an orthogonal set of two EGRH probes. This configuration has the ability to control both the longitudinal and transversal dimensions of the reconstructed target’s image, rather than controlling the spatial resolution, by increasing the frequency band that can be easily affected by medium losses. The system is tested numerically and experimentally by the detection of a cylindrical target within a human brain model., This work was financially supported by CICYT PID2019-107885GB-C31, and support grants for university departments and research units (FI-SDUR)(2021 FISDU 00195). This work was also supported by the National Center for Scientific and Technological Research (CNRST) under grant number PPR2/2015/36., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Technology assessment of aperture coupled slot antenna array in Groove Gapwaveguide for 5G millimeter wave applications

  • Zhou, Ivan
  • Jofre Roca, Lluís
  • Romeu Robert, Jordi
A compact triple-layer series fed slot unit array using Groove Gap Waveguide (GGW) technology for 5G millimeter-wave applications is presented in this paper. The design employed a two-step coupling mechanism for the radiating slots. The aperture coupling design when combined with the groove gapWaveguide (GGW) technology allows achieving three different goals: First, a reduction of the array size in the transversal direction, so more unit arrays can be added without grating lobes. Secondly, low insertion losses with high radiation efficiency. And third, a reduction of the manufacturing complexity with good stability against fabrication tolerances of up to 0.1 mm, making the design feasible to be massively deployed. The antenna was fabricated and measured showing good agreement with the numerical simulation results, the antenna provides a peak realized gain of 12.15dB at the central frequency of operation and a fractional bandwidth (FBW) of 9%., This work was supported in part by the Agencia Estatal Investigación under Grant PID2019-107885GB-C31/AEI/10.13039; and in part by the Catalan Research Group under Grant 2017SGR219, Grant MDM2016-O6OO, and Grant DI2020-043., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

On the influence of fabrication tolerances in Terahertz photoconductive antennas

  • Vega Piña, Sara
  • Nuño Gómez, Daniel-Juan
  • Chang, Yi
  • Gómez Díaz, J. Sebastián
  • Santos Blanco, M. Concepción
© 2025 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., We present a study of the radiation pattern of photoconductive antennas (PCA) subject to substrate chip defects, aiming at characterizing fabrication tolerances. We show that the asymmetries observed over the cross-polar radiation patterns may be exploited to numerically estimate the most prominent trends of the substrate chip geometrical imperfections. A Figure of Merit (FoM) has been defined, characterized and validated through simulations and experimental measures, proving it is sensitive to both the magnitude and location of the substrate irregularities. The study has been focused on two kinds of substrate defects, the angled dicing and the off-centered antenna gap, and it has considered three planar antenna geometries: dipole, bow-tie and Sierpinski triangle dipole. A numerical antenna factor related to the planar antenna geometry imprinted over the substrate is included in the FoM expression for fair comparison of substrate irregularities among PCAs with different metallic patterns. A simple setup for experimentally obtaining the value of the FoM through collimated beam raster scanning measure of the cross-polar radiation pattern has been proved useful to validate the practical relevance of the FoM. These values asses the substrate chip fabrication quality and help to identify the position and magnitude of the substrate defects that have the greatest impact on the PCA performance., This work was supported by the Spanish Ministerio de Ciencia e In- novaci´on (MICINN) thanks to the project PID2019-107885GB-C31 VER- SONET (RTI2018-097051), the Catalan Research Group grant 2017 SGR 219 and the University and Research Aid Management Agency (AGAUR) with pre-doctoral grant 2021 FISDU 00094 to the first author. (Corresponding author: Sara Vega), Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Calibration alignment sensitivity in corneal terahertz imaging

  • Zarrinkhat, Faezeh
  • Baggio, Mariangela
  • Lamberg, Joel
  • Tamminen, Aleksi
  • Nefedova, Irina
  • Ala-Laurinaho, Juha
  • Khaled, Elsayed E. M.
  • Rius Casals, Juan Manuel
  • Romeu Robert, Jordi
  • Taylor, Zachary
Improving the longitudinal modes coupling in layered spherical structure contributes significantly to corneal terahertz sensing, which plays a crucial role in the early diagnosis of cornea dystrophies. Using a steel sphere to calibrate reflection from the cornea sample assists in enhancing the resolution of longitudinal modes. The requirement and challenges toward applying the calibration sphere are introduced and addressed. Six corneas with different properties are spotted to study the effect of perturbations in the calibration sphere in a frequency range from 100 GHz to 600 GHz. A particle-swarm optimization algorithm is employed to quantify corneal characteristics considering cases of accurately calibrated and perturbed calibrated scenarios. For the first case, the study is carried out with signal-to-noise values of 40 dB, 50 dB and 60 dB at waveguide bands WR-5.1, WR-3.4, and WR-2.2. As expected, better estimation is achieved in high-SNR cases. Furthermore, the lower waveguide band is revealed as the most proper band for the assessment of corneal features. For perturbed cases, the analysis is continued for the noise level of 60 dB in the three waveguide bands. Consequently, the error in the estimation of corneal properties rises significantly (around 30%)., This research was funded by the Agencia Estatal de Investigación PID2019-107885GB-C31/AEI/10.13039, PRE2018-084326, and Academy of Finland Project number 327640., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Nested fast adaptive cross approximation algorithm for solving electromagnetic scattering problems

  • Fang, Xiaoxing
  • Heldring, Alexander
  • Rius Casals, Juan Manuel
  • Chen, Xinlei
  • Cao, Qunsheng
In this paper, a Nested Fast Adaptive Cross Approximation (NFACA) algorithm is presented to accelerate the solution of electromagnetic scattering problems. It is based on the Fast Adaptive Cross Approximation (FACA) and the Nested Cross Approximation (NCA). In the NFACA, the FACA is applied instead of the ACA or the Chebyshev nodes, to enhance the efficiency. It is shown to have O(N) storage and computational complexity for electrically small problems. Different from the conventional NCA or the Fast Nested Cross Approximation (FNCA), the pivot-selection does not rely on a preliminary selection with Chebyshev nodes or ACA for each group. The NFACA permits the selection of the optimum pivots independently at each level to make the accuracy controllable. Numerical results of several objects are presented to demonstrate the performance of this method. Compared with the FACA and NCA in solving the electromagnetic scattering problems, the NFACA is more efficient both in computational cost and storage. Compared with the FNCA, the NFACA is both faster and more accurate., This work was supported in part by the National Nature Science Foundation of China under Grant 61871219, Grant 61771238, and Grant 61501227; in part by the Post-Graduate Research and Practice Innovation Program of Jiangsu Province under Grant KYCX18_0289; in part by the China Scholarship Council under Grant 201906830042; in part by the Spanish Ministerio de Ciencia e Innovacion (MICINN) under Project TEC2016-78028-C3-1-P, Project PID 2019-107885GB-C31, Project TEC2017-83343-C4-2-R, and Project MDM2016-0600; and in part by the Catalan Research Group 2017 SGR 219., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Resonance-based microwave monitoring of live/dead bacteria in a microfluidic channel

  • Ataa-Allah, Houda
  • Aznabet, Mariem
  • Palacios Arias, César Augusto
  • Akazzim, Youness
  • El mrabet, Otman
  • Jofre Cruanyes, Marc
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
In this work, we have studied a highly sensitive microwave sensor for the detection of Escherichia coli (E. coli) bacteria at the single-cell level. The proposed system integrates a microwave sensor with a microfluidic channel for bacteria flow control. The microwave sensor is based on a planar microwave annular ring resonator working around 5GHz. Inside the channel, E. coli bacteria have been modeled using dielectric characteristics present in state-of-the-art literature. To enhance field confinement and achieve the highest electric field strength we have introduced two 50um gaps into the resonator. This approach holds great potential for different applications, including food safety control, healthcare diagnosis, and environmental monitoring, where the ability to detect a single E. coli cell is paramount., This work was financially supported in part by ID2019- 107885GBC31, PID2022-136869NB-C31, 2021 SGR 01415, Metropolis PLEC2021-007609, (FI-SDUR) (2021 FISDU 00195), PDR-2014- 2022/56-30157-2021-2 Generalitat de Catalunya, and Prueba de Concepto PDC2022-133091-I00 Ministerio de Ciencia, Innovacion y Universidades (Spain)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Split-ring resonator based microwave microfluidic biosensor for single bioparticle position location and live/dead cell differentiation

  • Ataa-Allah, Houda
  • Ataa Allah, Fatima
  • Palacios Arias, César Augusto
  • Aznabet, Mariem
  • El mrabet, Otman
  • Jofre Cruanyes, Marc
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
© 2026 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This paper presents a novel microwave biosensor integrated with a microfluidic platform for the label-free detection and differentiation of biological particles, including live and dead Escherichia coli (E. coli). The sensor is based on a 50 O microstrip line coupled to an annular split-ring resonator (SRR), designed and fabricated for a high sensitivity response to changes in the dielectric properties on the bioparticle. The integration with a microfluidic channel allows precise control and delivery of biological samples to the sensing region. Experiments demonstrated the sensor’s ability to detect individual microbeads and distinguish between single live and dead bacterial cells through measurable shifts in resonance frequency. Furthermore, by applying an Inverse Fast Fourier Transform (IFFT) to the differential transmission parameter, the system enables the spatial localization of single particles within the microfluidic channel. The results indicate significant potential for point-of-care diagnostics and environmental monitoring applications, highlighting the advantages of microwave biosensing for real-time, single-particle analysis., This work was supported in part by the Generalitat de Catalunya and European Regional Development Fund (FEDER) under Grant PDR-2014-2022/56-30157-2021-2A, Grant 2021 SGR 01415 Q0818003F, and Grant Metropolis PLEC 2021-007609, in part by the Agencia Estatal de Investigación, Spain under Grant CICYT PID2019107885GB-C31, Grant PID2022-136869NB-C31 funded byMICIU / AEI / 10.13039 / 501100011033/ FEDER, UE, and Grant Prueba de Concepto PDC 2022-133091-I00, in part by NextGeneration EU, in part by the CNRST as part of the “PhD-AssociateScholarship–PASS” Program., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

UWB-modulated microwave imaging for human brain functional monitoring

  • Akazzim, Youness
  • Jofre Cruanyes, Marc
  • El Mrabet, Otman
  • Romeu Robert, Jordi
  • Jofre Roca, Lluís
Morphological microwave imaging has shown interesting results on reconstructing biological objects inside the human body, and these parameters represent their actual biological condition, but not their biological activity. In this paper, we propose a novel microwave technique to locate the low-frequency (f≃1 kHz) -modulated signals produced by a microtag mimicking an action potential and proved it in a cylindrical phantom of the brain region. A set of two combined UWB microwave applicators, operating in the 0.5 to 2.5 GHz frequency band and producing a nsec interrogation pulse, is able to focus its radiated field into a small region of the brain containing the microtag with a modulated photodiode. The illuminating UWB microwave field was first modulated by the low-frequency (f≃1 kHz) electrical signal produced by the photodiode, inducing modulated microwave currents into the microtag that reradiating back towards the focusing applicators. At the receiving end, the low-frequency (f≃1 kHz) -modulated signal was first extracted from the full set of the backscattered signals, then focused into the region of interest and spatially represented in the corresponding region of the brain, resulting in a spatial resolution of the images in the order of 10 mm., This work was financially supported by the CICYT PID2019-107885GB-C31 and PDC2022-133091-I00 grants of the Agencia Estatal de Investigacion (Spain) and the PDR-2014-2022/56-30157-021-2A grant from Generalitat de Catalunya (Spain), as well as support grants for university departments and research units (FI-SDUR) (2021 FISDU 00195). This work was also supported by the National Center for Scientific and Technological Research (CNRST) under Grant Number PPR2/2015/36., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

A parallel Monte Carlo method for solving electromagnetic scattering in clusters of dielectric objects

  • López Menchón, Héctor
  • Úbeda Farré, Eduard
  • Heldring, Alexander
  • Rius Casals, Juan Manuel
In this work, we develop a novel Monte Carlo method for solving the electromagnetic scattering problem for clusters of photonic particles. The method is based on a formal solution of the scattering problem as a modified Born series whose coefficients are found by a conformal transformation. The terms of the Born series are approximated by sampling random elements of its matrix representation, computed by the Method of Moments. Unlike other techniques like the Fast Multiple Method, this Monte Carlo method does not require communication between processors, which makes it suitable for large parallel executions., This work was partly funded by the Ministerio de Ciencia e Innovacion (MICINN) under projects PID2019- 107885GB-C31 / AEI / 10.13039/501100011033, PID2020-113832RB-C21 / AEI / 10.13039/501100011033 and TEC2017-84817-C2-2-R / AEI / 10.13039/501100011033 and the Unidad de Excelencia Maria de Maeztu MDM- 2016-0600/AEI/10.13039/501100011033, which is financed by the Agencia Estatal de Investigación, Spain, and Catalan Research Group 2017 SGR 219 and grant 2021 FI B2 00096., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Proposal for the deployment of an augmented reality tool for construction safety inspection

  • Ramos Hurtado, Jorge
  • Muñoz La Rivera, Felipe
  • Mora Serrano, Javier
  • Deraemaeker, Arnaud
  • Valero Moreno, José Ignacio
The construction site is a hazardous place. The dynamic, complex interaction between workers, machinery, and the environment leads to dangerous risks. In response to such risks, the goal is to fulfill the zero accidents philosophy, which requires the development of safety skills among workers and the provision of tools for risk prevention. In pursuit of that vision, this work studies collective protective equipment (CPE). Traditional methodologies propose visual inspections using checklists, the effectiveness of which depends on the quality of the inspection by the safety advisor (SA). This paper analyses the traditional process of safety inspections in building projects: the traditional methods, main pain points, and bottlenecks are identified, along with the key performance indicators (KPIs) needed to complete these processes correctly. Because of this, a methodology that digitises the CPE inspection process is proposed. Augmented reality (AR) is used as a 3D viewer with an intuitive interface for the SA, and, accordingly, functional requirements are detailed and different information layers and user interfaces for AR applications are proposed. In addition, the workflow and KPIs are shown. To demonstrate the feasibility of the proposal, a proof of concept is developed and evaluated. The relevance of this work lies in providing background for the use of AR in safety inspection processes on construction sites and in offering methodological recommendations for the development and evaluation of these applications., This work has been supported by the Ministry of Science, Innovation and Universities of Spain (MICIU) through the BIMIoTICa project (RTC-2017-6454-7) and by the CONICYT for its economic support to Felipe Muñoz, beneficiary of a pre-doctoral grant (CONICYT—PCHA/International Doctorate/2019-72200306). The authors also acknowledge the financial support from the Spanish Ministry of Economy and Competitiveness, through the “Severo Ochoa Centre of Excellence (2019–2023) under the grant CEX2018-000797-S funded by MCIN/AEI/10.13039/501100011033”., Peer Reviewed, Postprint (published version)