Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Determination of benzomercaptans in environmental complex samples by combining zeolitic imidazolate framework-8-based solid-phase extraction and high-performance liquid chromatography with UV detection

  • Martinez-Perez-Cejuela, Hector
  • Mompo-Rosello, Oscar
  • Crespi-Sanchez, Neus
  • Palomino Cabello, Carlos
  • Simo-Alfonso, Ernesto F.
  • Herrero-Martinez, Jose Manuel
  • Catalá-Icardo, Mónica|||0000-0001-5897-8501
[EN] In this work, the synthesis of zeolitic imidazolate framework-8 (ZIF-8) crystals and their subsequent application as effective sorbents for extraction and preconcentration of several benzomercaptans from environmental complex samples is described. These materials were prepared by solvothermal approach varying the concentration of n-butylamine modulator to modify the surface of the metal-organic framework. The resulting materials were characterized by scanning and transmission electron microscopy, powder X-ray diffraction and Fourier transform infrared spectroscopy. The ZIF-8 material that gave the best features was selected as extractive phase and the influence of various parameters (sample pH and elution solvent composition, among others) on the extraction efficiency of target compounds were investigated. Under the optimal conditions of the method, the tested analytes (2-mercaptobenzothiazole, 2-mercaptobenzoxazole and 2-mercapto-6-nitrobenzothiazole) were retained and eluted quantitatively with alkaline 50:50 (v:v) methanol-water mixture. Using the proposed method, low limits of detection, in the range of 16-21 ng L-1 for aqueous samples and 0.4-0.5 mu g kg(-1) for soil samples, were achieved whereas the precision (expressed as relative standard deviation) was lower than 7%. The resulting solid-phase extraction protocol, using the zeolitic material as sorbent, was combined with liquid chromatography and ultraviolet-vis detector and successfully applied to determine traces of these organic pollutants in environmental samples. (C) 2020 Elsevier B.V. All rights reserved., The authors would like to gratefully acknowledge the financial support received from the project RTI2018-095536-B-I00 (Ministry of Science, Innovation and Universities, Spain). Spanish Agencia Estatal de Investigacion (AEI-Spain) and the European Funds for Regional Development (FEDER-European Union) are also gratefully acknowledged for financial support through Project CTQ2016-77155-R (AEI/FEDER, UE).). H. M. P-C. and N.C. thank the support from the Spanish Ministry of Science, Innovation and Universities (MCIU) for FPU pre-doctoral fellowships. The authors extend their appreciation to MCIU for granting the Spanish Network of Excellence in Sample preparation (RED2018-102522-T). This article is based upon work from the Sample Preparation Task Force and Network, supported by the Division of Analytical Chemistry of the European Chemical Society.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Weak anion-exchange mixed-mode materials to selectively extract acidic compounds by stir bar sorptive extraction from environmental waters

  • Nadal, Joan Carles
  • Borrull, Francesc
  • Herrero-Martínez, José Manuel
  • Marcé, Rosa Maria
  • Fontanals, Núria
  • Catalá-Icardo, Mónica|||0000-0001-5897-8501
[EN] In this study, the first example of a polytetrafluoroethylene (PTFE)-based magnet coated with weak anion exchange (WAX) monolith as novel support for stir bar sorptive extraction (SBSE) is presented. Firstly, the PTFE magnets were properly modified and vinylized in order to immobilize polymer monoliths onto its surface. Then, a glycidyl methacrylate monolith was prepared and modified with ethylenediamine (EDA) to create weak anion exchanger via ring opening reaction of epoxy groups. The prepared covalently immobilized EDA-modified monoliths onto PTFE magnet exhibited good stability and reusability. Application of resulting material as stir bar for SBSE was investigated for a series of acidic compounds that includes acesulfame, saccharin, diclofenac or ibuprofen, among others as target compounds. Firstly, the SBSE conditions were optimized to promote the WAX interactions with the target compounds achieving recoveries from 37 to 75% and enable the selective extraction of these compounds as it provided values of% matrix effect from 17 to -13% when they were determined by SBSE followed by liquid chromatography - tandem mass spectrometry. The analytical methodology, was then validated and applied for the determination of the target solutes in environmental water samples, which were found at concentration up to 2500 ng L¿1 in river waters, The authors would like to thank MCIN/AEI/10.23039/501100011033/and FEDER for financial support projects: CTQ2017-88548-P, RTI2018-095536-B-I00 and RED2018-102522-T. J.C. Nadal is also grateful to Universitat Rovira i Virgili (URV) for his PhD grant (2017PMF-PIPF-49). This article is based upon work from the Sample Preparation Task Force and Network, supported by the Division of Analytical Chemistry of the European Chemical Society.
Repositori Institucional UIB
Publicación Artículo científico (JournalArticle)

Determination of benzomercaptans in environmental complex samples by combining zeolitic imidazolate framework-8-based solid-phase extraction and high-performance liquid chromatography with UV detection

  • Martínez Pérez-Cejuela, Héctor
  • Mompó Roselló, Óscar
  • Crespí Sánchez, Neus
  • Palomino Cabello, Carlos
  • Catalá Icardo, Mónica
  • Simó Alfonso, Ernesto F.
  • Herrero Martínez, José Manuel
[eng] In this work, the synthesis of zeolitic imidazolate framework-8 (ZIF-8) crystals and their subsequent application as effective sorbents for extraction and preconcentration of several benzomercaptans from environmental complex samples is described. These materials were prepared by solvothermal approach varying the concentration of n-butylamine modulator to modify the surface of the metal-organic frame- work. The resulting materials were characterized by scanning and transmission electron microscopy, pow- der X-ray diffraction and Fourier transform infrared spectroscopy. The ZIF-8 material that gave the best features was selected as extractive phase and the influence of various parameters (sample pH and elu- tion solvent composition, among others) on the extraction efficiency of target compounds were inves- tigated. Under the optimal conditions of the method, the tested analytes (2-mercaptobenzothiazole, 2- mercaptobenzoxazole and 2-mercapto-6-nitrobenzothiazole) were retained and eluted quantitatively with alkaline 50:50 (v:v) methanol-water mixture. Using the proposed method, low limits of detection, in the range of 16–21 ng L −1 for aqueous samples and 0.4–0.5 μg kg −1 for soil samples, were achieved whereas the precision (expressed as relative standard deviation) was lower than 7%. The resulting solid-phase ex- traction protocol, using the zeolitic material as sorbent, was combined with liquid chromatography and ultraviolet-vis detector and successfully applied to determine traces of these organic pollutants in envi- ronmental samples.
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Global evaluation of the chemical hazard of recycled tire crumb rubber employed on worldwide synthetic turf football pitches

  • Armada Álvarez, Daniel
  • Llompart Vizoso, María del Pilar
  • Celeiro Montero, María
  • García Castro, Pablo
  • Ratola, Nuno
  • Dagnac, Thierry
  • de Boer, Jacob
Social and environmental concern about the use of crumb rubber from end-of-life car tires in the construction of different sport and recreational facilities is increasing due to the presence of hazardous compounds. The aim of this research was the assessment of 42 organic chemicals, including polycyclic aromatic hydrocarbons (PAHs), phthalates, adipates, antioxidants and vulcanisation agents in a large number of infill samples (91) from synthetic turf football pitches of diverse characteristics and geographical origin. Samples were taken worldwide, in 17 countries on 4 continents, to show the global dimension of this problem. Ultrasound assisted extraction was employed to extract the target compounds, followed by gas chromatography coupled to tandem-mass spectrometry (UAE-GC–MS/MS). Seventy-eight crumb rubber samples as well as thirteen samples of alternatives materials, such as cork granulates, thermoplastic elastomers and coconut fibre, were analyzed. The results highlight the presence of all target PAH in most rubber samples at concentrations up to μg g−1, including the eight ECHA (European Chemicals Agency) PAHs considered as carcinogenic, and anthracene (ANC), pyrene (PYR) and benzo[ghi]perylene (B[ghi]P), catalogued as substances of very high concern (SVHC). Endocrine disruptors such as some plasticizers (mainly phthalates), and other compounds like benzothiazole (BTZ) and 2-mercaptobenzothiazole (MBTZ) were found reaching the mg g−1 level. This confirms the presence of the hazardous substances in the recycled crumb rubber samples collected all around the world. Three crumb rubber samples exceeded the limit of 20 μg g−1 for the sum of the eight ECHA PAHs. Regarding the chemical composition of other infill alternatives, cork appears to be adequate, while the thermoplastic elastomers contained high levels of some plasticizers. In addition, the plastic infill as well as the crumb rubber both are microplastics. Microplastics are considered contaminants of emerging concern since they do not biodegrade and remain in the environment for a long time
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Assessment of the bioaccessibility of PAHs and other hazardous compounds present in recycled tire rubber employed in synthetic football fields

  • Armada Álvarez, Daniel
  • Martínez Fernández, Antía
  • Celeiro Montero, María
  • Dagnac, Thierry
  • Llompart Vizoso, María del Pilar
Recycled tire crumb rubber (RTCR) surfaces contain harmful and carcinogenic substances, which can be ingested by the users of these facilities, mainly athletes and children. In this work, the potential in-vitro oral bioaccessibility of eighteen polycyclic aromatic hydrocarbons (PAHs) from RTCR employed as infill in synthetic football fields was studied in human synthetic body fluids (saliva, gastric, duodenal and bile), prepared according the Unified Bioaccessibility Method. Solid-phase extraction (SPE) using commercial sorbents and a new green material based on cork (cork industry by-product) were used to isolate the bioaccessible PAHs before gas chromatography-tandem mass spectrometry analysis. The method was optimized and validated attending the analytical figures of merit. The feasibility of cork biosorbent for the extraction of the compounds was demonstrated, as well as the suitability of the UBM method to perform the digestion with good precision. The application to real samples collected from football fields demonstrated the presence of 17 of the 18 target PAHs in the biofluids. Most volatile PAHs such as NAP, ACY, ACE, FLU, PHN and ANC, achieved the highest bioaccessibility percentage levels. The carcinogenic B[a]P was detected in 75 % of the samples at concentrations up to 2.5 ng g−1 (bioaccessible fraction). Children exposure assessment was carried out to identify potential risk. Other hazardous and environmentally problematic compounds such as N-(1,3-Dimethylbutyl)-N′-phenyl-p-phenylenediamine-quinone (6PPD-quinone), recently related with the dead of coho salmon, and hexamethoxymethylmelamine (HMMM), among others, were also detected. This is the first study in which the bioaccesibility from real crumb rubber samples of 15 out of the 16 PAHs considered as priority pollutants by the United States Environmental Protection Agency (EPA) and the presence of 6PPD-quinone and HMMM in the bioaccessible fractions is reported
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Vitamin E determination in edible oils by reversed-phase dispersive liquid-liquid microextraction and screen-printed carbon electrodes

  • Diuzheva, Alina
  • Fernández Martínez, Elena
  • Vidal, Lorena
  • Andruch, Vasil
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
A novel simple, environmentally friendly and portable method to determine vitamin E in edible oils based on reversed-phase dispersive liquid-liquid microextraction combined with electrochemical detection using screen-printed carbon electrodes (SPCEs) has been developed. Vitamin E was extracted from oil samples into a 4 M HCl aqueous solution and determined by differential pulse voltammetry using SPCEs. The extraction conditions optimized by experimental design (i.e., Plackett-Burman and central composite designs) were: aqueous 4 M HCl extractant volume, 43 µL; extraction time, 2 min; centrifugation time, 10 min; and centrifugation speed, 3000 rpm. The proposed method requires a standard addition calibration approach, and the working range showed good linearity from 0 to 20 mg L−1, with a correlation coefficient ranging from 0.990 to 0.995 (N=5). The methodological limit of detection was between 1 and 3 mg L−1. The repeatability of the proposed method was evaluated at 15 mg L−1, and the relative standard deviation ranged between 10 and 15% (n=5). For the quantification of vitamin E in ten commercial samples of olive, sesame, soybean, sunflower and a mixture of sunflower and corn oils, the volume of the extractant phase (i.e., 4 M HCl aqueous solution) was increased up to 100 µL and satisfactory recoveries were obtained in the range of 85-115%, confirming the applicability of the method.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Electrochemical Sensor for the Determination of Methylthiouracil in Meat Samples

  • Marco, Andrea
  • Canals, Antonio
  • Morallon, Emilia
  • Aguirre Pastor, Miguel Ángel
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Marco, Andrea|||/items/ed30abdd-8076-4a93-a527-2b2d5366f59f
  • Morallon, Emilia|||/items/a15cf511-9365-4c40-afcb-ea29d4418244
Two analytical methods based on miniaturized electrochemical sensors, voltammetric and amperometric sensors, have been developed for the determination of 6-methyl-2-thiouracil (MTU) in meat consumption samples (beef liver and foie). A multivariate approach has been considered to optimize the experimental procedure including extraction and electrochemical detection. Under optimal conditions and at a typical working potential of 1.55 V (vs Ag pseudo-reference electrode), response is linear in the range 0 to 20 µg L−1 MTU concentration range. The empirical limit of detection is 0.13 µg L−1, lower than the maximum concentration established by legislation. The electrochemical methods have been used to analyze MTU-spiked meat samples, and recovery values varying between 85 and 95% with coefficients of variation <30%. The analytical methods developed with the miniaturized electrochemical sensors can successfully determine the concentration of MTU in real meat samples with high accuracy, being the results obtained similar to those provided by other methods such as UV-Vis spectrophotometry. Finally, the degree of sustainability of the electrochemical sensors-based developed method has been quantified by means of the Analytical Eco-Scale.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Dispersive liquid–liquid microextraction of Cd, Hg and Pb from medicines prior to ICP OES determination according to the United States Pharmacopeia

  • Pinheiro, Fernanda C.
  • Aguirre Pastor, Miguel Ángel
  • Nóbrega, Joaquim A.
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
A simple, sensitive and matrix-effect free analytical method for simultaneous determination of Cd, Hg and Pb in drug samples (i.e., commercial dosage tablets) by inductively coupled plasma optical emission spectrometry (ICP OES) has been developed. According to the United States Pharmacopeia (USP) Chapter 232, those metals are considered elemental impurities from class 1 and they must be assessed in pharmaceutical production as well as in quality control evaluation. In order to increase the sensitivity of the analysis, dispersive liquid–liquid microextraction (DLLME) was performed and seven factors affecting analyte extraction were optimized by multivariate analysis. A microvolume of analyte enriched phase was directly introduced into the plasma using a multi-nebulizer, providing a high enrichment factor. When compared to conventional ICP OES analysis, DLLME improves the limit of quantitation (LOQ) values on average 40-fold for all analytes. Consequently, LOQ values were significantly lower than their permissible daily exposure limits for oral drugs. Accuracy was evaluated by addition and recovery experiments following USP recommendations in eight commercial drug samples. Recovery and RSD values were within the range of 90–108% and 1–9%, respectively.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Dispersive liquid-liquid microextraction based on deep eutectic solvent for elemental impurities determination in oral and parenteral drugs by inductively coupled plasma optical emission spectrometry

  • Pinheiro, Fernanda C.
  • Aguirre Pastor, Miguel Ángel
  • Nóbrega, Joaquim A.
  • González-Gallardo, Nerea
  • Ramón, Diego J.
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Ramón, Diego J.|||/items/cede7c2c-35fe-43e3-8148-905611ae6646
  • González-Gallardo, Nerea|||/items/cb9393bb-82cb-4197-b0eb-b0839aa18ee5
A simple, fast, sensitive and green pretreatment method for determination of Cd, Co, Hg, Ni, Pb and V in oral and parenteral drug samples using inductively coupled plasma optical emission spectrometry (ICP OES) has been developed. According to United States Pharmacopoeia (USP), those metals must be reported in all pharmaceutical products for quality control evaluation (i.e., elemental impurities from classes 1 and 2A of USP Chapter 232). To improve the analytical capabilities of ICP OES, a dispersive liquid-liquid microextraction (DLLME) has performed using a safe, cheap and biodegradable deep eutectic solvent (DES) as extractant solvent (a mixture of 2:1 molar ratio of DL-menthol and decanoic acid). Seven parameters affecting the microextraction efficiency have carefully optimized by multivariate analysis. Under optimized conditions, the DES-based DLLME-ICP OES procedure improved limit of quantitation (LOQ) values on range from 12 to 85-fold and afforded an enrichment factor on average 60-times higher than those obtained to direct ICP OES analysis. Consequently, LOQ values for Cd, Co, Hg, Ni, Pb and V have been on average 10-times lower than target limits recommended for drugs from parenteral route of administration. Trueness has evaluated by addition and recovery experiments following USP recommendations for three oral drug samples in liquid dosage form and three parenteral drugs. Recovery and RSD values have been within the range of 90-109% and 1-6%, respectively. All analytes were below the repectives LOQ values, hence, lower than the limits proposed by USP Chapter 232.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Reversed-phase dispersive liquid–liquid microextraction for elemental analysis of gasoline by inductively coupled plasma optical emission spectrometry

  • Vidal, Ezequiel
  • Lorenzetti, Anabela S.
  • Álvarez, Mónica B.
  • Domini, Claudia E.
  • Aguirre Pastor, Miguel Ángel
  • Vidal, Lorena
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
In this work a green and fast sample preparation method based on reversed-phase dispersive liquid–liquid microextraction (RP-DLLME) was developed for the separation and preconcentration of several elements (i.e., Ag, As, Ba, Cd, Cr, Cu, Hg, Mn, Mo, Ni, Pb, S, Se, Sn and V) in gasoline samples before determination by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). The extraction procedure was carried out in a reverse mode, since a small volume of the aqueous phase (i.e., 8 M HCl) is used to extract a relatively high volume of the organic phase (i.e., gasoline sample). Unlike conventional DLLME, in RP-DLLME the analytes were extracted from the organic phase into the aqueous phase. The experimental conditions for the microextraction procedure were: 5 g of sample, 8 M HCl as the extractant phase, mechanical agitation by vortex as the dispersion system, 115 μL of extractant volume, and 2 min extraction and 5 min centrifugation time. Under optimized extraction conditions the enrichment factor ranged between 3 and 53, and the limits of detection ranged between 0.02 and 50 μg kg−1. The proposed analytical method was validated and successfully used to analyze three gasoline samples. All gasoline samples were spiked at 100 μg kg−1 for all analytes, except sulfur (in this case at 1000 μg kg−1), obtaining recovery and RSD values within the range of 88–109% and 2–9%, respectively.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Magnetic deep eutectic solvents in microextraction techniques

  • Aguirre Pastor, Miguel Ángel
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
Magnetic deep eutectic solvents (MDESs) have recently produced a torrent of pioneering applications in endless areas of sample preparation. By including a magnetic nanomaterial (e.g., magnetic nanoparticles) or a paramagnetic anion (e.g., [FeCl4]-) in their structure, MDESs exhibit a strong response under the application of an external magnetic field. Furthermore, the use of MDESs, as a sorbent or solvent in extraction techniques, have been scarcely employed to develop green analytical methods, characterized by the avoid of time-consuming steps and the use of toxic organic solvents, as well as the application of small amounts of MDESs, for the determination of organic and inorganic contaminants, drugs, proteins, among others in environmental, food and biological matrices. This review highlights the application of MDESs in sample preparation in analytical chemistry. Challenges and future outlooks of new MDESs are also presented.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Disolventes eutécticos: nuevas estrategias como fase extractante y como membrana líquida soportada

  • Zapater, Cristina
  • Rubio, Iván
  • Aguirre Pastor, Miguel Ángel
  • Vidal, Lorena
  • Canals, Antonio
  • Zapater, Cristina|||/items/167e0084-0fbb-4747-9758-ade350b2e3e2
  • Rubio, Iván|||/items/772cfa96-2abc-46bb-a27a-eefd47ad6c5d
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
En el presente estudio se ha evaluado la viabilidad analítica de emplear disolventes eutécticos (DES) hidrofóbicos e hidrofílicos en procedimientos de microextracción. Por un lado, el DES hidrofílico compuesto por cloruro de colina (ChCl) y etilenglicol (EG) (ChCl:EG, relación molar 1:2) se utilizó como fase extractante en la técnica de (micro)extracción líquido-líquido dispersiva (DLLME, Dispersive Liquid-Liquid Microextraction) para la extracción de cuatro bisfenoles (i.e., BPA, BPF, BPAP y BPAF) en aceites comestibles, comparando su rendimiento analítico con el de su compuesto puro (EG) y su variante magnética (ChCl:EG:FeCl3·6H2O, relación molar 1:4:1). Por otro lado, se ha utilizado un DES hidrofóbico como membrana líquida soportada (SLM, Supported Liquid Membrane) en la técnica de extracción por electromembrana (EME, Electromembrane Extraction) de diferentes antiinflamatorios para su determinación en muestras de agua y orina. En ambos estudios, la determinación se realizó mediante cromatografía de líquidos acoplada a un detector de diodos en serie (LC-DAD).
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

A novel non-invasive colorectal cancer diagnostic method: Volatile organic compounds as biomarkers

  • Alustiza, Miren
  • Ripoll-Seguer, Laura
  • Canals, Antonio
  • Murcia Pomares, Óscar
  • Martínez-Roca, Alejandro
  • García-Heredia, Anabel
  • Giner-Calabuig, Mar
  • Jover, Rodrigo
  • Vidal, Lorena
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
Introduction: Population-based fecal tests for colorectal cancer (CRC) screening have shown to reduce mortality thanks to the early detection of the disease. However, currently available fecal tests are limited in their sensitivity and specificity. Our aim is to look for volatile organic compounds in fecal samples as biomarkers for CRC detection. Material and Methods: Eighty participants were included; 24 had adenocarcinoma, 24 had adenomatous polyps and 32 presented no neoplasms. Fecal samples were collected 48 h preceding the colonoscopy from all participants, except CRC patient samples that were collected after 3–4 weeks from the colonoscopy. Magnetic headspace adsorptive extraction (Mag-HSAE) followed by thermal desorption-gas chromatography-mass spectrometry (TD-GC–MS) was performed on stool samples to identify volatile organic compounds as biomarkers. Results: p-Cresol was significantly more abundant in the cancer samples (P < 0.001) with an area under the curve (AUC) of 0.85 (CI 95%; 0.737–0.953), having a sensitivity and specificity of 83% and 82%, respectively. In addition, 3(4H)-dibenzofuranone,4a,9b-dihydro-8,9b-dimethyl- (3(4H)-DBZ) was also more abundant in the cancer samples (P < 0.001) with an AUC of 0.77 (CI 95%; 0.635–0.905), sensitivity of 78% and specificity of 75%. When combined (p-cresol and 3(4H)-DBZ), the AUC was 0.86, sensitivity 87% and specificity 79%. p-Cresol also appeared to be promising as a biomarker for pre-malignant lesions with an AUC of 0.69 (CI 95%; 0.534–0.862), sensitivity 83% and specificity 63%, P = 0.045. Conclusions: Volatile organic compounds emitted from feces and determined by a sensitive analytical methodology (Mag-HSAE-TD-GC–MS), employing a magnetic graphene oxide as extractant phase, could be used as a potential screening technology for CRC and pre-malignant lesions.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Evaluation of 2-hydroxyethyl methacrylate as comonomer in the preparation of water-compatible molecularly imprinted polymers for triazinic herbicides

  • Díaz-Álvarez, Myriam
  • Martín Esteban, Antonio
  • Turiel Trujillo, Esther
10 Pág., In this work, the preparation and evaluation of water-compatible molecularly imprinted polymers for triazines using 2-hydroxyethyl methacrylate and methacrylic acid as comonomers is described. Four sets of molecularly imprinted and non-imprinted polymers for propazine were prepared at varying monomer molar ratios (from 4:0 to 1:3), and evaluated for the recognition of several triazines directly in aqueous media. The evaluation was performed by loading 1 ml of an aqueous solution containing 500 ng of each selected triazine, washing with 500 μl of acetonitrile, and eluting with 500 μl of methanol followed by 2 × 500 μl of a solution of methanol containing 10% of acetic acid. Final determinations were performed by high-performance liquid chromatography-ultraviolet detection. Improvement in molecular recognition of triazines in water was obtained on those molecularly imprinted polymers incorporating 2-hydroxyethyl methacrylate in 3:1 or 2:2 molar ratios, being the former selected as optimum providing recoveries for propazine up to 80%. A molecularly imprinted solid-phase extraction protocol was developed to ensure that triazines-selective recognition takes place inside selective binding sites in pure water media. Finally, the developed method was successfully applied to the determination of the selected triazines in environmental waters providing limits of detection from 0.16 and the 0.5 μg/L concentration range., This article is based upon work from the National Thematic Network on Sample Treatment (RED-2018-102522-T) funded by the Spanish Ministry of Science, Innovation and Universities, and the Sample Preparation Study Group and Network, supported by the Division of Analytical Chemistry of the European Chemical Society., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Green molecularly imprinted polymers for sustainable sample preparation

  • Martín Esteban, Antonio
15 Pág., The use of molecularly imprinted polymers in sample preparation as selective sorbent materials has received great attention during the last years leading to analytical methods with unprecedented selectivity. However, with the progressive implementation of Green Analytical Chemistry principles, it is necessary to critically review the greenness of synthesis and further use of molecularly imprinted polymers in sample preparation. Accordingly, in the present review, the different steps and strategies for the preparation of molecularly imprinted polymers, the used reagents, as well as their incorporation to microextraction techniques are reviewed from a green perspective and recent alternatives to make the use of molecularly imprinted polymers more sustainable are provided., This article is based upon work from the National Thematic Network on Sample Treatment (RED-2018-102522-T) funded by the Spanish Ministry of Science, Innovation and Universities, and the Sample Preparation Study Group and Network, supported by the Division of Analytical Chemistry of the European, Peer reviewed