Skip to main content

ANALISIS DE DEFECTOS EN LAMINADOS REFORZADOS CON FIBRAS DEBIDOS A PROCESOS DE FABRICACION Y EFECTO EN EL COMPORTAMIENTO A FATIGA

PID2020-118480RB-C22

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2020
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD CARLOS III DE MADRID

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Rapid fatigue life estimation of drilled CFRP laminates and titanium stacks using thermography

  • Calvo, Jose Vicente|||0000-0001-8488-1762
  • Feito-Sánchez, Norberto|||0000-0001-7330-6404
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Miguélez, María Henar
[EN] In this work, we estimate the fatigue life of drilled Carbon Fiber Reinforced Polymer (CFRP) laminates making use of the temperature evolution of the component. As the self-heating effect due to cyclic loading causes a temperature change in the initial stages of the loading, the slope of the temperature variation ¿T versus the number of cycles can be used to estimate the remaining life. We have validated the applicability of the procedure for drilled laminates under different cutting conditions, and for drilled Ti-CFRP stacks. Infrared thermography was used to obtain the temperature variation during cycling loading. The results proved that the obtained adjusted model can effectively estimate the fatigue life of CFRP laminates with delamination damage or thermal damage with an error of 15%, proving the usefulness of this methodology for drilled and stacked laminates., This research is part of the R + D + i project PID2020-118480RBC21,-C22, and PID2023-151610OB-C21,-C22, funded by MCIN/AEI/ 10.13039/501100011033 and by ERDF A way of making Europe . Grant PRE2018-086277 funded by MCIN/AEI/10.13039/ 501100011033 and by ESF Investing in your future . The funding of the Generalitat Valenciana, Programme PROMETEO 2021/046 and project GV/2021/060 is also acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The role of the interfaces and cross-links on the mechanical behavior of mineralized collagen fibrils. A numerical approach

  • Vercher Martínez, Ana|||0000-0003-3695-6461
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Fuenmayor Fernández, Francisco-Javier|||0000-0003-3594-9593
  • García-Aznar, J. Manuel
[EN] Mechanical properties of bone tissue are highly dependent on its hierarchical structure. The presence of microcracks and diffuse damage in lamellar bone is correlated with the failure of the collagen-mineral interface in mineralized collagen fibrils (MCF). The main goal of this work is to evaluate the mechanical behavior of the interfaces and quantify the stiffness loss of the MCF associated with different failure mechanisms, under controlled in-plane displacement. Additionally, we aim to study the role of the cross-links on the fibril mechanical response, beyond the interface failure. Inter- and intra-microfibrilar cross-links are analyzed. In order to address the first issue, a detailed representative volume of the MCF is analyzed by means of the finite element method, under the assumption of plane strain and periodic boundary conditions. In this model the interfaces between constituents are modeled with an exponential cohesive law. Enzymatic cross-links, located at the molecular terminals connecting each 4D (D = 67 nm) staggered molecules, are represented by non-linear springs. Three in-plane controlled deformations are applied. The results of this work provide the anisotropic stiffness loss of the tissue involved in the different failure mechanisms at the nano-scale length. The initiation of microcracks and the presence of damage zones are compatible with the failure mechanisms observed at interfaces. Interface failure entails a progressive stiffness loss, bringing a non-linear behavior of bone. The strength obtained for the longitudinal maximum deformation is more than 20 times the transverse strength and 3.5 times the shear strength. The quantification of the reduction percentage in the elastic moduli and the shear stiffness when the fibril is damaged, has a potential application in improving failure criteria based on degradation of elastic constants. When longitudinal elongation is applied, the mechanical contribution of the cross-links in delaying the failure initiation of the interface is shown. Likewise, results of this work confirm the scarce influence of the cross-links in the strain range analyzed. Additionally, a threedimensional numerical model of several microfibrils is defined with the aim of analyzing the mechanical relevance of inter- and intra-microfibrilar cross-links, beyond the interface failure. Results confirm that cross-links transfer the load when strain increases, being highlighted the mechanical competence of the trivalent cross-links., The authors acknowledge the Ministerio de Ciencia e Innovacion y Universidades and the European Regional Development Fund (FEDER) for the financial support received through the projects PID2020-118920RB-I00, PID2020-118480RB-C21 and C22 funded by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe", the Ministerio de Ciencia e Innovacion y Universidades MCIN/AEI/10.13039/501100011033 and Europe Union Next Generation EU/PRTR for the projects PDC2021-121368-C21 and C22, CRUE-Universitat Politecnica de Valencia and the Generalitat Valenciana for Programa PROMETEO/2021/046.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Design and mechanics of stackable auxetic S-shaped structures

  • Rufo-Martin, Celia
  • Diaz-Alvarez, Jose
  • Miguelez, Maria Henar
  • Youssef, George
  • Infante-García, Diego|||0000-0001-6010-2031
[EN] The emerging auxetic lattices, driven by contemporary advancements in additive manufacturing, have garnered significant attention, with an emphasis on improving structural performance and energy absorption efficiencies while mitigating the contributions of material nonlinearities and instabilities. This research advances the state of the art of thin-strut auxetic structures by introducing a stacking schema to realize 3D S-shaped polystructures with rigid-body motion-dominated deformation, spatial symmetry, and persistent auxeticity. Several generations of these polystructures were 3D printed using vat photopolymerization with varying strut thickness ranging from 1 mm to 3 mm. The additively manufactured structures were mechanically tested under quasi-static and impact loading scenarios, providing physical evidence for the foreseen structural behaviors discussed above. The polystructures yielded load-bearing-to-mass ratios of 4.6 kN/kg, 7.6 kN/kg, and 12.3 kN/kg for t1, t2, and t3, respectively, with less than 10 g of weight, a result of the rigid body motion and the asymmetric rotation of the polystructure beams. Additionally, the impact response highlighted a structure-to-material transition, resulting in similar force maxima for t1 and t2, with 9 and 10 N (structure-dominated), whereas t3 reported a force of up to 49 N (material-dominated). However, irrespective of the strut thickness, the negative Poisson's ratio remained nearly unchanged (-0.22 +/- 0.02), exemplifying the importance of the structural mechanics substantiated by the specific topological design of S-shaped unit cells. The research findings paved the way for the translational potential of S-shaped polystructures in practical applications for mitigating impact, including civilian and military loading conditions., The authors acknowledge the support of the National Science Foundation under Grant No. 2035663 (G.Y.) . Funding from the U.S. Department of Defense (W911NF1410039, W911NF1810477, W911NF2310150, and N00174-23-1-0009) is also acknowledged. The authors are also grateful for internal funding from San Diego State University and Universidad Carlos III de Madrid. In particular, this work was supported by the MCIN/AEI/10.13039/501100011033 and "European Union NextGenerationEU/PRTR" under grant PDC2021-121368-C21; the MCIN/AEI/10.13039/501100011033 under grants PID2020-112628RA-I00 and PID2020-118480RB-C22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Influence of material extrusion parameters on fracture mechanisms of polylactic acid under three-point bending

  • Álvarez-Blanco, Mario
  • Arias-Blanco, Adrián
  • Marco, Miguel
  • Miguélez, María Henar
  • Infante-García, Diego|||0000-0001-6010-2031
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
[EN] In this work, a thorough fracture assessment of additive manufactured specimens made by 3D printed polylactic acid (PLA) under three-point bending is presented. This polymer is widely used in additive manufacturing for numerous applications, gaining prominence in fields such as biomechanics. Prismatic fully dense specimens and lattice structure specimens with different raster orientations and densities were fabricated using the material extrusion-based additive manufacturing technique. The objective is to analyse the effect of relevant process parameters on the fracture mechanism of short beam specimens tested under three-point bending. Digital image correlation and computed tomography have been used to measure the full field displacement and internal defects, respectively. Furthermore, the theory of critical distances was applied to assess the mechanical strength of lattice structure specimens. The results have shown the strong influence of raster orientation on the mechanical strength and fracture patterns even for negative air gap values. The transition from brittle to ductile failure was observed when changing density and raster orientation. Lastly, neck-shaped defects were detected in knots of specimens manufactured with a grid pattern. Defects in grid pattern specimens appear due to the prescribed path followed by the extruder during the building process. They were the main source causing a decrease in the mechanical strength and fracture trajectories. The objective of this research is to enhance the knowledge on the mechanical response of 3D printed components and to give an in-depth failure assessment., The authors gratefully acknowledge the funding support received from the Spanish Ministerio de Ciencia e Innovacion for funding the projects PID2020-112628RA-I00 and PID2020-118480RB-C21, -C22, MCIN/AEI / 10.13039/501100011033 and by "ERDF A way of making Europe"; project PDC2021-121368-C21 and C22 funded by MCIN/AEI/ 10.13039/501100011033 and by the "European Union NextGenerationEU/PRTR". The authors also thank the funding received from Madrid Community (Spain) through the project IND2020/IND-17413. The financial support of Generalitat Valenciana and European Social Fund through Programme PROMETEO 2021/046 and CIAPOS/2021/271 is also acknowledged. Lastly, the Universitat Politecnica de Valencia is acknowledged for the financial support through PAID-PD-22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Development of bone surrogates by material extrusion-based additive manufacturing to mimic flexural mechanical behaviour and fracture prediction via phase-field approach

  • Álvarez-Blanco, Mario
  • Marco, Miguel
  • Miguélez, M. Henar
  • Infante-García, Diego|||0000-0001-6010-2031
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
[EN] Background and objective: The limited availability of human bone samples for investigation leads to the demand for alternatives. Bone surrogates are crucial in promoting research on the intricate mechanics of osseous tissue. However, solutions are restricted to commercial brands, which frequently fail to faithfully replicate the mechanical response of bone, or oversimplified customised simulants designed for a specific application. The manufacturing and assessment of reliable bone surrogates made of polylactic acid via material extrusion-based additive manufacturing are presented in this work. Methods: An experimental and numerical study with 3D-printed dog -bone and prismatic specimens was carried out to characterise the polymeric feedstock and analyse the influence of process parameters under three-point bending and quasi-static conditions. Besides, three porcine rib samples were considered as a reference for the development of the artificial bones. Bone surrogates were manufactured from the 3D-scanned real bone geometries. In order to reproduce the trabecular and cortical bone, a lattice structure for the infill and a compact shell surrounding the core were employed. Infill density and shell thickness were evaluated through different printing configurations. Additionally, a computational analysis based on the phase-field approach was conducted to simulate the experimental tests and predict fracture. The modelling considered homogenisation of the infill material. Results: Outcomes demonstrated the potential of the presented methodology. Maximum force and flexural stiffness were compared to real bone properties to find the optimal printing configuration, replicating the flexural mechanical behaviour of bone tissue. Certain configurations accurately reproduce the studied properties. Regarding the numerical model, strength and stiffness prediction was validated with experimental results. Conclusions: The presented methodology enables the manufacturing of artificial bones with accurate geometries and tailored mechanical properties. Furthermore, the described modelling strategy offers a powerful tool for designing bone surrogates., The authors gratefully acknowledge the funding support received from the Spanish Ministerio de Ciencia e Innovacion for funding the projects PID2020-112628RA-I00, PID2020-118480RB-C21 and C22, funded by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe", and the funding received from the Madrid Community (Spain) through the project IND2020/IND-17413. The authors are also grateful for the funding received from Generalitat Valenciana and European Social Fund programmes PROMETEO/2021/046 and CIAPOS/2021/271, and to Universitat Politecnica de Valencia for the grant PAID-PD-22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental and numerical analysis of the influence of intramedullary nail position on the cut-out phenomenon

  • Arias-Blanco, A.
  • Marco, M.
  • Larraínzar-Garijo, R.
  • Miguélez, M. H.
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
[EN] Background and objective: Proximal femur fractures, colloquially known as hip fractures, are a common pathology with increasing incidence in the last years due to the enhanced ageing population. Regarding the extracapsular fracture, the treatment for this pathology consists of a fixation of the fragments using an osteosynthesis device, mainly the intramedullary nail. This repairing method implies several complications, which may include the failure of the fixation device, frequently occurring due to the "cut-out" mechanism. The present work focuses on the study of how the position of the cephalic screw, which should be fixed during surgery, affects the cut-out risk. Through experimental tests and numerical models some variables that can be critical for the cut-out phenomenon are analysed. Methods: This study has been carried out through a numerical model based on the finite element method and experimental tests. The digital image correlation technique has been used in experimental tests to measure displacements on the femoral surface with the objective of numerical model validation. Some basic daily activities with different intramedullary nail positions have been analysed through the numerical model, considering variables that can induce the cut-out complication. Results: The results show how the intramedullary nail position clearly influences the cut-out risk, showing that displacements in the upper, anterior and posterior direction increase the cut-out risk, while displacement in the lower direction endangers the intramedullary nail itself. Thus, the centred position is the one which reduces the cut-out risk. Conclusions: This work supposes an improvement in the knowledge of the cut-out phenomenon thanks to the combination of experimental testing and validated numerical models. The effects of different intramedullary nail positions in the femoral head are studied, including a novelty variable as torque, which is critical for the structural integrity of the fixation. The main conclusion of the work is the determination of the central intramedullary nail position as the most favourable one for decreasing the cut-out risk., The authors gratefully acknowledge the funding support received from the Spanish Ministry of Science and Innovation for funding project PID2020-112628RA-I00/AEI/10.13039/501100011033, projects PID2020-118480RB-C21 and -C22 and from the Madrid Community (Spain) through the project IND2020/IND-17413. The financial support of the European Union NextGenerationEU/PRTR through grant number PDC2021-121368-C21 and -C22 and the Generalitat Valenciana through Programme PROMETEO 2021/046 is also acknowledged.& nbsp;
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Aplicación de termografía infrarroja en la estimación de la vida a fatiga en laminados de CFRP taladrados.

  • Calvo, Jose Vicente|||0000-0001-8488-1762
  • Feito-Sánchez, Norberto|||0000-0001-7330-6404
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Miguélez, María Henar
[ES] La aplicación de técnicas no destructivas para evaluar materiales compuestos sometidos a fatiga es un área de creciente interés entre la comunidad científica. Entre las técnicas disponibles, destaca el uso de la termografía infrarroja debido a su asequibilidad, simplicidad y resultados prometedores en investigaciones previas. En este estudio, se aplica la termografía infrarroja con el objetivo de obtener modelos predictivos capaces de estimar el límite de fatiga de laminados gruesos de CFRP (polímero reforzado con fibra de carbono) sometidos a cargas de tracción. Los ensayos experimentales conllevan la monitorización de la temperatura en laminados con características típicas de la industria aeroespacial, a través de una cámara termográfica. La campaña experimental implica la variación de los niveles de daño por taladrado y las cargas cíclicas de tracción. Con los datos obtenidos de la evolución de la temperatura durante la fase inicial de los ensayos de fatiga se obtienen modelos analíticos predictivos del límite de fatiga. Los resultados indican que el modelo propuesto es capaz de predecir de manera eficiente el límite de fatiga con una alta fiabilidad, mostrando una sólida correlación entre las predicciones y los resultados experimentales, por lo que este estudio subraya la utilidad de las técnicas termográficas para evaluar el daño y predecir el límite de fatiga de laminados CFRP en diversas condiciones de carga, Los autores agradecen la financiación a través de los siguientes proyectos: PID2020-118480RB-C21 y C22, financiado por MCIN/AEI/ 10.13039/501100011033 y por FEDER Una manera de hacer Europa ; proyecto PDC2021-121368-C21 y C22 financiado por MCIN/AEI/ 10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR ; ayuda PRE2018-086277 financiada por MCIN/AEI/10.13039 /501100011033 y por FSE Invierte en tu futuro . También agradecen la financiación de la Generalitat Valenciana, programa PROMETEO 2021/046 y el proyecto GV/2021/060.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Influence of machining parameters on fretting fatigue life of Inconel 718

  • Infante-García, Diego|||0000-0001-6010-2031
  • Belda Ricardo|||0000-0003-3913-5773
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Díaz-Álvarez, A.
  • Díaz-Álvarez, J.
  • Cantero, J.L.
  • Miguélez, M.H.
[EN] This work focuses on the analysis of the influence of different machining factors on the fretting fatigue behaviour of Inconel 718. Fretting fatigue tests using a flat-to-flat with rounded edges contact were carried out using specimens with different manufacturing process parameters. The results pointed out the high impact that machining parameters possess in the Inconel 718 fatigue lifetime. Tool wear has shown to be the most significant parameter. Residual stresses measured along the direction of fatigue load have proved to be a relevant indicator of the fretting fatigue behaviour. Lastly, surface roughness has been shown to possess a weaker influence., The authors gratefully acknowledge the funding support received from the Spanish Ministerio de Ciencia e Innovación and the FEDER operation program for funding the projects PID2020-118480RB-C22 and PID2020-118480RB-C21 and the Generalitat Valenciana (Programme PROMETEO 2021/046).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Printable and Tunable Bioresin with Strategically Decorated Molecular Structures

  • Rufo-Martín, Celia
  • Díaz-Álvarez, José
  • Miguélez, Henar
  • Youssef, George
  • Infante-García, Diego|||0000-0001-6010-2031
[EN] As personalized medicine rapidly evolves, there is a critical demand for advanced biocompatible materials surpassing current additive manufacturing capabilities. This study presents a novel printable bioresin engineered with tunable mechanical, thermal, and biocompatibility properties through strategic molecular modifications. The study introduces a new bioresin comprising methyl methacrylate (MMA), ethylene glycol dimethacrylate (EGDMA), and a photoinitiator, which is further enhanced by incorporating high molecular weight polymethyl methacrylate (PMMA) to improve biostability and mechanical performance. The integration of printable PMMA presents several synthesis and processing challenges, necessitating substantial modifications to the 3D printing process. Additionally, the bioresin is functionalized with antibacterial silver oxide and bone-growth-promoting hydroxyapatite at various weight ratios to extend its application further. The results demonstrate the agile printability of the novel bioresin and its potential for transformative impact in biomedical applications, offering a versatile material platform for additive manufacturing-enabled personalized medicine. This work highlights the adaptability of the novel printable bioresin for real-life applications and its capacity for multiscale structural tailoring, potentially achieving properties comparable to native tissues and extending beyond conventional additive manufacturing techniques., The authors acknowledge the support of the National Science Foundation under Grant No. 2035663. The authors are also grateful for internal funding from San Diego State University. Funding from the United States Department of Defense (W911NF1410039, W911NF1810477, W911NF2310150, and N00174-23-1-0009) is also acknowledged. Additionally, this work was supported by the MCIN/AEI/10.13039/501100011033 and "European Union NextGenerationEU/PRTR" under grant PDC2021-121368-C21; the MCIN/AEI/10.13039/501100011033 under grants PID2020-112628RA-I00 and PID2020-118480RB-C22; and by the Generalitat Valenciana under grant CIAPOS/2021/271.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Influence of distributed out-of-plane waviness defects on the mechanical behavior of CFRP laminates

  • Calvo, Jose Vicente|||0000-0001-8488-1762
  • Quiñonero-Moya, Antonio Ramón|||0000-0002-2370-7960
  • Feito-Sánchez, Norberto|||0000-0001-7330-6404
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Miguélez, María Henar
[EN] One of the most common defects induced during manufacturing of laminates is out-of-plane fibre waviness. This defect significantly affects the mechanical behavior of the laminate and reduces fatigue life and the load capacity of the material. Therefore, it is important to understand the impact of fibre waviness on the performance of composite laminates. In this work, multiple out-of-plane waves have been introduced throughout a Carbon Fibre Reinforced Polymer (CFRP) laminate at different thickness positions. The specimens were tested under tensile loading and an analysis of the surface of the laminate has been carried out by means of Digital Image Correlation (DIC). The results obtained by DIC were able to predict the apparent strain of the laminate quite accurately, as well as locate up to seven undulations at different depths. It was proved that a laminate with multiple wrinkles has 16% less tensile load strength. The results were used to validate different Finite Element (FE) models of the laminate showing a good agreement. These simple models were able to predict the initiation and propagation of failure in both the matrix and the fibre., This research is part of the R + D + i project PID2020-118480RB-C21 and C22, funded by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe". Grant PDC2021-121368-C21 and C22 funded by MCIN/AEI/10.13039/501100011033 and by the "European Union NextGenerationEU/PRTR". Grant PRE2018-086277 and PRE2021-097626 funded by MCIN/AEI/10.13039/501100011033 and by "ESF Investing in your future". The funding of the Generalitat Valenciana, Programme PROMETEO 2021/046 and project GV/2021/060, is also acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Development, 3D printing, and mechanics of novel auxetic unit cell monostructures

  • Rufo-Martín, Celia
  • Díaz-Álvarez, José
  • Miguélez, María Henar
  • Koohbor, Behrad
  • Youssef, George
  • Infante-García, Diego|||0000-0001-6010-2031
[EN] Complex structures with unique mechanics are pivotal to advancing additive manufacturing, enabling applications where traditional methods are impractical. This study presents a novel 3D auxetic S-shaped monostructure designed for scalability, tunability, and printability using vat photopolymerization. Unit cell geometries were fabricated and experimentally evaluated under quasi-static loading conditions, with full-field analyses providing insights into their structural performance. Benchmarking against common auxetic structures (re-entrant and star topologies) highlighted the superior capabilities of the proposed design. The S-shaped monostructures exhibited geometric insensitivity in their force-displacement responses, with a stiffness of similar to 180 N/m, withstanding large displacements of 11 mm without fracture or self-contact and supporting forces up to 1.8 N (i.e., 95 times their weight) before fully recovering upon unloading. Computational and experimental results demonstrated robust spatial auxeticity, persisting up to 85 % of axial global displacement due to geometry-driven rigid body motion, independent of base material properties. The S-shaped structures achieved superior auxetic performance (nu(maxti) approximate to -0.43) compared to re-entrant (nu(maxti) approximate to -0.30) and star (nu(maxti) approximate to - 0.05) counterparts, with a monotonic and reversible auxetic response throughout loading. Strain contour analyses from digital image correlation validated the reduced stress concentrations and rigid body-dominated mechanism. The exceptional auxeticity and mechanical resilience of the S-shaped monostructures suggest promising applications in advanced designs, including 3D stackable configurations for impact mitigation applications., The authors acknowledge the support of the National Science Foundation under Grant No. 2035663 (G.Y.) and Grant No. 2035660 (B. K.) . The authors are also grateful for internal funding from San Diego State University, Rowan University, and Universidad Carlos III de Madrid. In particular, this work was supported by the MCIN/AEI/10.13039/501100011033 and "European Union NextGenerationEU/PRTR" under grant PDC2021-121368-C21; the MCIN/AEI/10.13039/501100011033 under grants PID2020-112628RA-I00 and PID2020-118480RB-C22. Funding from the U.S. Department of Defense (W911NF1410039, W911NF1810477, W911NF2310150, and N00174-23-1-0009) is also acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Modeling the delamination failure under compressive loads in CFRP laminates based on digital image correlation analysis

  • Calvo, Jose Vicente|||0000-0001-8488-1762
  • Feito-Sánchez, Norberto|||0000-0001-7330-6404
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Miguélez, María Henar
[EN] Laminate composite materials such as CFRPs are highly susceptible to delamination, being one of the common failure modes in composite laminates. The combination of severe delamination with uniaxial compressive loads leads to the loss of stability and structure failure. In this study, the authors present an experimental and numerical analysis of this effect in laminates. A series of tests were carried out with four different specimens including delamination-free plates and plates with incipient delamination with different damage size and location. 3D Digital Imagen Correlation technique was applied to predict the buckling initiation and propagation and to validate the numerical models implemented, showing good agreement between the numerical and experimental results. Model material failure includes Hashin criterion and cohesive zone model (CZM) to predict delamination. Finally, numerical models have been used to predict the crack initiation and progression in the rest of samples., This research was funded by the FEDER programme and the Spanish Ministry of Science and Innovation, under projects DPI2017-89197-C2-1-R, DPI2017-89197-C2-2-R, PID2020-118480RB-C21, PID2020-118480RB-C22 and the associated predoctoral subprogram PRE2018-086277. The funding of the Generalitat Valenciana, Programme PROMETEO 2021/046 and project GV 2021/156, is also acknowledged.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

The role of the interfaces and cross-links on the mechanical behavior of mineralized collagen fibrils. A numerical approach

  • Vercher-Martínez, Ana
  • Giner, Eugenio
  • Fuenmayor, F. Javier
  • García-Aznar, J. Manuel
Mechanical properties of bone tissue are highly dependent on its hierarchical structure. The presence of microcracks and diffuse damage in lamellar bone is correlated with the failure of the collagen-mineral interface in mineralized collagen fibrils (MCF). The main goal of this work is to evaluate the mechanical behavior of the interfaces and quantify the stiffness loss of the MCF associated with different failure mechanisms, under controlled in-plane displacement. Additionally, we aim to study the role of the cross-links on the fibril mechanical response, beyond the interface failure. Inter- and intra-microfibrilar cross-links are analyzed. In order to address the first issue, a detailed representative volume of the MCF is analyzed by means of the finite element method, under the assumption of plane strain and periodic boundary conditions. In this model the interfaces between constituents are modeled with an exponential cohesive law. Enzymatic cross-links, located at the molecular terminals connecting each 4D ( ) staggered molecules, are represented by non-linear springs. Three in-plane controlled deformations are applied. The results of this work provide the anisotropic stiffness loss of the tissue involved in the different failure mechanisms at the nano-scale length. The initiation of microcracks and the presence of damage zones are compatible with the failure mechanisms observed at interfaces. Interface failure entails a progressive stiffness loss, bringing a non-linear behavior of bone. The strength obtained for the longitudinal maximum deformation is more than 20 times the transverse strength and 3.5 times the shear strength. The quantification of the reduction percentage in the elastic moduli and the shear stiffness when the fibril is damaged, has a potential application in improving failure criteria based on degradation of elastic constants. When longitudinal elongation is applied, the mechanical contribution of the cross-links in delaying the failure initiation of the interface is shown. Likewise, results of this work confirm the scarce influence of the cross-links in the strain range analyzed. Additionally, a three-dimensional numerical model of several microfibrils is defined with the aim of analyzing the mechanical relevance of inter- and intra-microfibrilar cross-links, beyond the interface failure. Results confirm that cross-links transfer the load when strain increases, being highlighted the mechanical competence of the trivalent cross-links.