Pasar al contenido principal

MEJORA DE LA SOSTENIBILIDAD, SEGURIDAD Y RESILIENCIA DE LA CONEXION ENTRE VIGAS SEGMENTADAS PREFABRICADAS DE HORMIGON MEDIANTE EL USO DE NUEVOS MATERIALES.

RTI2018-099091-B-C21

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Analysis of the shear strength mechanism of slender precast concrete beams with cast-in-place slab and web reinforcement

  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] Precast concrete beams with cast-in-place slabs on top, namely concrete composite beams are frequently used for building concrete bridge decks. In designs, the contribution of cast-in-place slabs to shear strength tends to be omitted. However, given the vast number of existent bridges with this deck typology, significant cost savings could be made when assessing these structures if the slab's shear strength is considered. This paper analyses how cast-in-place slab influences the shear behaviour of concrete composite beams with web reinforcement. For this purpose, an experimental programme of 18 concrete specimens with web reinforcement and rectangular crosssections was run, in which the following parameters varied: cross-sectional depth; existence of an interface between concretes; compressive strengths of the concrete of beams and slabs; differential shrinkage between concretes. It was observed that: the slab contributed to resist shear; the existence of an interface between concretes led to a crack appearing along it that caused the transmitted shear to be divided into two load paths: one through the precast beam and another one through the slab; the slab's concrete strength was that which mainly influenced the element's shear strength; differential shrinkage did not reduce shear strength. Based on experimental observations, a mechanical model is proposed in this paper to assess the composite elements' shear strength, which considers the yielding of both stirrups and the slab's longitudinal reinforcement to be a failure criterion, which well predicted the experimental results. The shear formulations of Eurocode 2, the Level III Approximation of Model Code 2010 and the (b) Formula of ACI 318-19 offered a similar result to the herein proposed method when using the entire composite element effective depth and the weighted average of the concrete strengths of both the beam and slab estimated from the area ratio. Codes significantly underestimated specimens' interface shear., The experimental programme of this research work was undertaken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV; Spain) with concrete supplied by Caplansa. The project was supported by the Spanish Min-istry of Science and Innovation through Projects BIA2015-64672-C4-4-R and RTI2018-099091-B-C21-AR; the Regional Government of Valencia through Project AICO/2018/250; the European Union with FEDER funds. The authors thank the Spanish Ministry of Economy and Business for Grant BES-2016-078010 that supported Lisbel Rueda-Garcia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of high-strength SCC with and without steel fibres on the shear behaviour of dry joints in PCSBs

  • Traver-Abella, Celia
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Albiol Ibáñez, José Ramón|||0000-0003-3049-9693
[EN] The structural behaviour of precast concrete segmental bridges (PCSBs) heavily relies on the strength of the joints between segments. Multi-keyed dry joints are currently the most commonly used solution in these discontinuity zones. Employing high-strength concrete is becoming increasingly common in civil engineering given its higher strength and improved durability. It specifically allows higher prestressing levels in PCSBs. Using self-compacting concrete enhances workability and adding steel fibres improves mechanical properties. The existing scientific literature includes experimental tests to analyse the shear behaviour of castellated dry joints in different concrete types. However, no experimental tests appear specifically for the castellated dry joints made with high-strength self-compacting concrete (HS-SCC) with and without steel fibres. Therefore, this experimental study conducted 31 push-off-type tests to analyse the behaviour and shear capacity of dry joints made of HS-SCC by investigating the influence of adding steel fibres to the concrete mix. The study examined crack patterns, load-displacement behaviour, failure modes and different (cracking, ultimate and residual) loads. The addition of steel fibres improved joints¿ shear capacity. However, brittle behaviour was observed after reaching ultimate load when using HS-SCC, even when steel fibres were added to the concrete mix. Finally, the adequacy of existing formulations was analysed. Standard AASHTO proved to be on the unsafe side for the castellated dry joints specimens made of HS-SCC without steel fibres, and provided a good approximation for the specimens with steel fibres., The authors thank the financial support provided by Grants: PID2021-126397OB-I00 funded by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe"; RTI2018-099091-B-C21-AR by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe" and TED2021-129358B-I00 funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGeneration EU/PRTR". The authors also thank the Spanish Ministry of Universities for Grant FPU18/03310, which supported Celia Traver Abella. This research was undertaken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV; Spain).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental analysis of the shear resistance of precast concrete T-beams with a top cast-in-place slab

  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] Precast concrete T-beams with a cast-in-place slab on top are structural elements that are often employed in composite construction. Despite their widespread use, some aspects of their structural behaviour upon shear forces have not yet been studied in depth. Six composite specimens with different T-shaped cross-sections and concrete qualities, and with web reinforcement, were tested to analyse the shear transfer mechanisms and to assess the contribution of the cast-in-place slab to shear strength. The shear strength mechanisms deriving from experimental observations and measurements are provided. This study indicates that: placing a concrete cast-in-place slab on top of a prefabricated T-beam increases its shear strength; interface shear strength plays an essential role in concrete composite elements¿ vertical shear strength; widening the cast-in-place slab width does not increase shear strength in this test programme specimens; the compressive strength of the precast beam¿s concrete significantly influences composite beams¿ shear resistances. The ACI 318-19 formulation best captures the influence of concrete strength on shear strength of the three formulations considered (EC2, MC-10 (Level III) and ACI 318-19). However, all of them tend to underestimate shear strengths compared to the experimental results., Ministerio de Ciencia e Innovacion (MCIN) and Agencia Estatal de Investigacion (AEI) supported the present research work through grants BIA2015-64672-C4-4-R and RTI2018-099091-B-C21-AR, both funded by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe". Author Lisbel Rueda-Garcia was supported by grant BES -2016-078010 funded by MCIN/AEI/10.13039/501100011033 and by "ESF Investing in your future". The project was also carried out with the support of the Regional Government of Valencia through Project AICO/2018/250. The open access charge was funded by CRUE- Universitat Politecnica de Valencia. This research work was under- taken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV; Spain) with concrete supplied by Caplansa.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental analysis of the shear strength of composite concrete beams without web reinforcement

  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] Composite concrete members without web reinforcement are often used in precast construction. The contribution of the cast-in-place concrete topping slab to vertical shear strength has been traditionally disregarded. However, significant cost savings can result from designing and assessing these structures if this contribution is considered. This paper presents the experimental study of a series of 21 monolithic and composite (precast beam and cast-in-place slab) specimens without web reinforcement, and with rectangular and T-shaped cross-sections, failing in shear. The vertical shear strength was analysed by the following test variables: cross-section shape, the existence of an interface between different aged concretes, strengths of the two concretes and the differential shrinkage effect. From these experimental tests, it was concluded that the slab contributed to shear strength, the use of high-strength concrete slightly increased specimens' shear strength and the differential shrinkage did not reduce shear strength. Specimens' failure modes were analysed based on their shear transfer mechanisms, noticing that the arching action in the slab was considerable after critical shear crack formation. The vertical shear strength experimental results were well predicted by the codes' formulations (Eurocode 2, Model Code 2010 and ACI 318-19) when composite beam depth was taken for the calculations instead of beam depth. Codes significantly underestimated the horizontal shear strengths of the composite specimens., This research has been supported by: the Spanish Ministry of Science and Innovation through Research Project BIA2015-64672-C4-4-R and RTI2018-099091-B-C21-AR; the Regional Government of Valencia through Project AICO/2018/250; the European Union with FEDER funds. The experimental programme was developed in the Laboratory of Concrete of the Institute of Concrete Science and Technology (ICITECH) of the Universitat Politècnica de València (UPV) with concrete supplied by Caplansa. The Spanish Ministry of Science and Innovation supported Lisbel Rueda through grant BES-2016-078010.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental study on the shear strength of reinforced concrete composite T-shaped beams with web reinforcement

  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] The current increasing use of precast concrete elements and cast-in-place concrete slabs, namely concrete composite elements, in construction requires a better understanding of their behaviour in shear. In this work, 19 T-shaped composite and monolithic specimens failing in shear were experimentally tested. Their results were compared to study the influence on the shear strength of: the flange width, the presence of an interface between concretes and the strength of the concretes of both beam and slab. The shear transfer mechanisms were analysed by adapting to these specimens a mechanical model previously proposed by the authors for rectangular composite beams. It was concluded that: the composite specimens¿ shear strength did not increase with widening flange width when the specimens showed an extended interface cracking, but increased when their crack pattern was similar to that of the monolithic specimens; the presence of an interface decreased the shear strength; the slab¿s concrete compressive strength modified the composite specimens¿ shear strength when the slab failed in shear, but not when the slab failed in bending or when the interface failed. The shear formulations of EC2, MC-10 Level III and ACI 318-19 gave good estimations when using the weighted average of the compressive strengths of the beam and slab concretes, similarly to those obtained with the proposed model. From the experimental results, the improvement of the interface shear strength of composite beams is proposed as a practical recommendation for increasing their shear strength. At the same time, the slab width and the slab¿s concrete strength could be increased with the same purpose. This work experimental findings and the adaptation of the mechanical model to T-shaped beams lay the groundwork for a future development of a shear design and assessment formulation for concrete composite elements., The authors would like to thank the Ministerio de Ciencia e Innovación (MCIN) and the Agencia Estatal de Investigación (AEI) for their support through grants BIA2015-64672-C4-4-R and RTI2018-099091-B-C21-AR, both funded by MCIN/AEI/ 10.13039/ 501100011033 and by ¿ERDF A way of making Europe¿. Author Lisbel Rueda-García was supported through grant BES-2016-078010 funded by MCIN/AEI/ 10.13039/501100011033 and by ¿ESF Investing in your future¿. The Regional Government of Valencia also supported this research through Project AICO/2018/250. This research work was undertaken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politècnica de València (UPV; Spain) with concrete supplied by Caplansa.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers

  • Pereiro-Barceló, Javier
  • Ciurana-Tatay, Álvaro
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Rueda-García, Lisbel|||0000-0002-2061-1656
[EN] Four precast column-to-foundation connection specimens, previously tested under lateral reversed cyclic loading and constant axial load (first-stage tests), were repaired with Carbon Fibre Reinforced Polymer (CFRP) layers in the areas where plastic hinges had formed and were retested under the same loads (second-stage tests). The columns were originally manufactured with ultrahigh-performance concrete (UHPC) with high stee-fibre content (volumetric steel/fibre ratio 1.9%). The steel bars in the connection were replaced with superelastic Ni-Ti SMA bars that crossed the column/foundation interface. Two types of connection between the precast column and the foundation were analysed: protruding bars and smooth pocket bars (SP). The specimens were subjected to the same constant level of relative axial load in both the first and second-stage tests. The objective was to determine whether the initial performance of precast UHPC and SMA reinforced column-to-foundation connections against lateral cyclic loads can be restored after a seismic event by means of simple and economic retrofitting. The effectiveness of the number of strengthening CFRP layers was also studied (two or three CFRP wrapping layers) for each column-to-foundation connection type. The main results for PB and SP connection specimens with respect to the original specimens were respectively: an average strength capacity loss of 8% and 19%, displacement ductility increase of 8% and 42%, dissipated energy 48% and 53% higher and initial stiffness 9.5% and 21% lower. No significant differences were observed in the repairs done with two or three CFRP wrapping layers., This paper forms part of a line of research carried out at the University Institute of Concrete Science and Technology (ICITECH) of the Universitat Politecnica de Valencia. The authors wish to thank the Spanish Ministry of Science and Innovation for the support provided through Projects BIA2012-32645 and RTI2018-099091-B-C21-AR, and Grant BES-2016-078010 from the European Union for the financial support with FEDER funds, and the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Feasibility of iron-based shape memory alloy strips for shear strengthening of damaged RC beams promoting the formation of plastic hinges

  • Traver-Abella, Celia
  • Ruiz Pinilla, Joaquín Guillermo
  • Monserrat-Lopez, Andrea
  • Montoya-Coronado, Luis A.
  • Ribas, Carlos
  • Cladera, Antoni
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Bonet Senach, José Luís|||0000-0002-6687-5307
[EN] This research focuses on the proof of concept of the feasibility of iron-based shape memory alloys strips (Fe-SMA) to strengthen damaged structures by promoting the yielding of longitudinal reinforcement. For this purpose, an experimental campaign on real-scale reinforced concrete beams previously damaged on shear and retested after being strengthened was carried out. The strengthening technique consists of external Fe-SMA strips wrapping the beams. The results show a very significant increase in both shear strength and ductility. In addition, shear predictions were calculated and compared by several design models. This study highlights the potentialities of Fe-SMA as a strengthening technique for damaged beams on shear., The authors would like to thank the financial support provided by Grants: PID2021-126397OB-I00, PID2021-123701OB-C22, BIA2015-64672-C4-4-R and BIA2015-3 64672-C4-3-R by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe."; RTI2018-099091-B-C21-AR and RTI2018-099091-B-C22 by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe" and BIA2015-64672-C4-4-R and BIA2015-64672-C4-3-R (AEI/FEDER, UE); and TED2021-129358B-I00 and TED2021-130272B-C22 funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGeneration EU/PRTR". The Regional Valencian Government also supported this research with Project AICO/2020/295. Andrea Monserrat is supported by the Ministry of Universities (Spain) with the Recovery, Transformation and Resilience Plan (RD 289/2021 and order UNI/551/2021) funded by NextGenerationEU. The authors thank the Spanish Ministry of Science and Innovation for Grant FPU18/03310 that supported Celia Traver Abella. This research work was undertaken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV; Spain), with concrete supplied by Caplansa. They also appreciate the contribution of the re-fer AG Strengthening Solution Company, which provided the memory steel (Fe-SMA strips).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Shear strength of self-compacting concrete dry joints subjected to combined axial, bending and shear forces in precast concrete segmental bridges

  • Traver-Abella, Celia
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] Castellated dry joints between segmental elements represent zones of discontinuity that affect the behaviour of precast concrete segmental bridges (PCSBs). These joints must be capable of transmitting combined axial, bending and shear forces. Under service conditions, the joints in PCSBs are designed to be closed, but can be allowed to be open under failure conditions. Experimental and numerical dry joint studies have focused mainly on the behaviour of dry joints subjected to direct shear with different confinement levels. However, the number of studies and tests with castellated dry joints under axial, bending and shear forces is very limited. Although self-compacting concrete (SCC) use is becoming increasingly common in precast concrete, shear resistance behaviour significantly differs between elements made of conventional vibrated concrete (CC) and SCC. No experimental tests of castellated dry joints made of normal-strength self-compacting concrete (NS-SCC) have been found. This work presents an experimental programme of 24 tests to understand the shear transfer mechanism through NS-SCC single-keyed and multi-keyed dry joints subjected to combined axial, bending and shear forces. In this work, a new test for push-off dry joint specimens subjected to combined shear and axial forces with or without eccentricity was designed. Significant differences were observed between closed and open joints regarding cracking patterns, joint kinematics, resistance mechanisms and failure mode. The experimental test results were compared to the provisions from AASHTO and Fouré. The analysed expressions generally overestimated closed and open joints¿ shear capacity., The authors would like to thank the financial support provided by Grants: PID2021 126397OB-I00 funded by MCIN/AEI/10.13039/501100011033 and by ERDF A way of making Europe ; RTI2018 099091-B-C21-AR by MCIN/AEI/10.13039/501100011033 and by ERDF A way of making Europe and TED2021 129358B-I00 funded by MCIN/AEI/ 10.13039/501100011033 and by the European Union NextGeneration EU/PRTR . The authors thank the Spanish Ministry of Universities for Grant FPU18/03310, which supported Celia Traver Abella. This research was undertaken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV; Spain). Funding for open access charge: CRUE-Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of steel fibres on the shear behaviour of SCC dry joints in precast segmental bridges

  • Traver-Abella, Celia
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Albiol Ibáñez, José Ramón|||0000-0003-3049-9693
[EN] The purpose of connections in precast concrete segmental bridges (PCSBs) is to transmit significant compressive and shear forces, ensuring the stability and stiffness of the structure. Castellated dry joints are increasingly used for the connection of precast concrete elements in these regions of discontinuity. Due to the low tensile strength of concrete, the use of steel fibres to improve the shear strength of this joint type has become widespread. In addition, in recent decades self-compacting concrete (SCC) has become popular in the precast industry due to its workability and ease of placement. Although there are experimental campaigns that studied the influence of steel fibres on the shear capacity of castellated dry joints, experimental tests using normal strength self-compacting concrete (NS-SCC), with and without steel fibres, have not been found. Therefore, this research analyses the influence of adding steel fibres to NS-SCC to improve the mechanical behaviour and shear strength of castellated dry joints in PCSBs. An experimental campaign of 37 push-off-type tests was conducted to assess their effect on the cracking, failure mode, shear strength and residual strength of the joint. The study revealed improvements in post-peak behaviour and shear capacity, which became more significant for higher steel fibre contents. A comparison to other authors¿ experimental results was made and indicated lower shear strength when using SCC. Additionally, the AASHTO formulation overestimated the shear strength of the NS-SCC joints tested in this study, except for the specimens with 80 kg/m3 of steel fibres., The authors thank the financial support provided by Grants: PID2021-126397OB-I00 funded by MCIN/AEI/10.13039/501100011033 and by ERDF A way of making Europe ; RTI2018-099091-B-C21-AR by MCIN/AEI/10.13039/501100011033 and by ERDF A way of making Europe and TED2021-129358B-I00 funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGeneration EU/PRTR . The authors also thank the Spanish Ministry of Universities for Grant FPU18/03310, which supported Celia Traver Abella. This research was undertaken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV; Spain). Funding for open access charge: CRUE-Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Towards the Development of a Formulation for Obtaining the Shear Strength of Concrete Composite Beams, Hacia el desarrollo de una formulación para la obtención de la resistencia a cortante de vigas compuestas de hormigón

  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] In the design and assessment of precast concrete beams with a slab cast on top, namely concrete composite beams, engineers still face in practice unsolved shear-related issues, such as the contribution to shear strength of the slab, the concrete strength to be considered in shear formulations or the influence of the interface between concretes in the shear behaviour. In the present research, 69 shear tests were performed on monolithic and composite beams, with rectangular or T-shaped cross-section, with or without transverse reinforcement and with different concrete qualities, to experimentally analyse the issues mentioned above. The study of the shear transfer mechanisms at failure led to formulating a model for explaining the observed results. Based on this model, a shear strength predictive formulation for concrete composite beams with web reinforcement has been developed, which has been verified with the experimental results from this research and 24 additional tests from the literature. This formulation provides accurate predictions compared to the shear strength formulations of current codes EC2, MC-10 and ACI 318-19. The proposed model lays the foundations for the future development of a user-friendly formulation for calculating the shear strength of concrete composite beams., [ES] En el diseño y evaluación de vigas prefabricadas de hormigón con una losa superior hormigonada in situ, es decir, vigas compuestas de hormigón, los ingenieros siguen enfrentándose en la práctica a problemas no resueltos relacionados con el cortante, como la contribución de la losa a la resistencia a cortante, la resistencia del hormigón que se ha de considerar en las formulaciones de cortante o la influencia de la interfaz entre hormigones en el comportamiento a cortante. En la presente investigación se han realizado 69 ensayos a cortante en vigas monolíticas y compuestas, de sección rectangular o en T, con o sin armadura transversal y con diferentes calidades de los hormigones, para analizar experimentalmente las cuestiones mencionadas anteriormente. El estudio de los mecanismos de transferencia de cortante condujo a la formulación de un modelo para explicar los resultados observados. A partir de este modelo, se ha desarrollado una formulación para predecir la resistencia a cortante en vigas compuestas de hormigón con armadura de cortante, la cual se ha verificado con los resultados experimentales de esta investigación y 24 ensayos adicionales de la literatura. Esta formulación proporciona resultados precisos comparados con las formulaciones de resistencia a cortante de los códigos actuales EC2, MC-10 y ACI 318-19. El modelo propuesto sienta las bases para el futuro desarrollo de una formulación fácil de usar para el cálculo de la resistencia a cortante de vigas compuestas de hormigón., Ministerio de Ciencia e Innovación (MCIN) and Agencia Estatal de Investigación (AEI) supported the present research work through grants BIA2015-64672-C4-4-R and RTI2018-099091-B-C21-AR, both funded by MCIN/ AEI/ 10.13039/501100011033 and by ERDF A way of making Europe . Author Lisbel Rueda-García was supported by grant BES-2016-078010 funded by MCIN/AEI/ 10.13039/501100011033 and by ESF Investing in your future . The project was also carried out with the support of the Regional Government of Valencia through Project AICO/2018/250. This research work was undertaken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politècnica de València (UPV; Spain) with concrete supplied by Caplansa.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Cyclic response of precast column-to-foundation connection using UHPC and Ni-Ti SMA reinforcements in columns

  • Pereiro-Barceló, Javier
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Albiol Ibáñez, José Ramón|||0000-0003-3049-9693
[EN] Earthquakes are catastrophic natural events with a special impact on reinforced concrete structures due to the horizontal loads that they introduce into structures. To adequately resist an earthquake, a precast structure must have a high deformation capacity, dissipate energy in each earthquake cycle, undergo less damage and fewer residual deformations. To achieve all this, the behaviour of precast columns made with UPHC was herein experimentally analysed. Steel rebars were replaced with Ni-Ti shape memory alloy (SMA) bars with super elasticity (SE) in the critical zone of the column-to-foundation connection. The Ni-Ti SMA bars crossed the interface between the column and foundation. Two types of connection with the foundation were studied: smooth pocket type and protruding bar type. Columns were subjected to constant compression and a cyclic lateral load. Rocking behaviour was observed at the connection critical section. The use of advanced materials allowed a moment-rotation behaviour of the connection to be developed without any significant damage. Low residual deformations were observed while testing because of both the damage in UHPC was low and the superelasticity of the Ni-Ti SMA bars., This paper forms part of a research line carried out at the Institute of Concrete Science and Technology (ICITECH) of the Universitat Politecnica de Valencia. The authors wish to thank to the Government of Spain Ministry of Economy and Competitiveness for the support it pro-vided through Project BIA2012-32645, to the Government of Spain Ministry of Science and Innovation for the project RTI2018-099091-B-C21-AR, and the grant BES-2016-078010, to the European Union for the financial support with FEDER funds and to the Government of Spain Ministry of Education, Culture and Sports for grant FPU12/01451.