Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 20
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Transparent single layer graphene electrodes for electroretinogram recordings

  • Cruz, Jose Manuel de la
  • Nguyen, Diep
  • Picaud, Serge
  • Hébert, Clement
  • Garrido, Jose A.
Resumen del trabajo presentado al MRS Fall Meeting and Exhibit, celebrado en Boston, Massachusetts (USA) del 1 al 6 de diciembre de 2019., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under Grant Agreement no. 732032 and the FIS2017-85787-R project financed by the Spanish Ministerio de Ciencia, Innovación y Universidades, the Spanish Research Agency (AEI) and the European Development Fund. The ICN2 is funded by the CERCA programme / Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Switchless multiplexing of graphene active sensor arrays for brain mapping

  • Garcia Cortadella, Ramon
  • Schäfer, Nathan
  • Cisneros-Fernández, J.
  • Ré, Lucía
  • Illa, Xavi
  • Schwesig, Gerrit
  • Moya, Ana
  • Santiago, Sara
  • Guirado, Gonzalo
  • Villa, Rosa
  • Sirota, Anton
  • Serra-Graells, Francesc
  • Garrido, Jose A.
  • Guimerà-Brunet, Anton
Sensor arrays used to detect electrophysiological signals from the brain are paramount in neuroscience. However, the number of sensors that can be interfaced with macroscopic data acquisition systems currently limits their bandwidth. This bottleneck originates in the fact that, typically, sensors are addressed individually, requiring a connection for each of them. Herein, we present the concept of frequency-division multiplexing (FDM) of neural signals by graphene sensors. We demonstrate the high performance of graphene transistors as mixers to perform amplitude modulation (AM) of neural signals in situ, which is used to transmit multiple signals through a shared metal line. This technology eliminates the need for switches, remarkably simplifying the technical complexity of state-of-the-art multiplexed neural probes. Besides, the scalability of FDM graphene neural probes has been thoroughly evaluated and their sensitivity demonstrated in vivo. Using this technology, we envision a new generation of high-count conformal neural probes for high bandwidth brain machine interfaces., This work has been funded by the European Union’s Horizon 2020 research and innovation programme under Grant Agreement 732032 (BrainCom), Grant Agreement 85219 and 881603 (Graphene Flagship). The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, funded by the Spanish Research Agency (AEI, Grant SEV-2017-0706), and by the CERCA Programme/Generalitat de Catalunya. R.G.C. and N.S. acknowledge that this work has been done in the framework of the Ph.D. in Electrical and Telecommunication Engineering at the Universitat Autonoma de Barcelona. R.G.C is supported by the International Ph.D. Programme La Caixa - Severo Ochoa (Programa Internacional de Becas “la Caixa”-Severo Ochoa). This work has made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS “NANBIOSIS”, more specifically by the Micro-NanoTechnology Unit of the CIBER in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN) at the IMB-CNM. This work is within the project 2DTecBio (FIS2017-85787-R) funded by the “Ministerio de Ciencia, Innovacion y Universidades” of Spain, the “Agencia Estatal de Investigacion (AEI)”, and the “Fondo Europeo de Desarrollo Regional (FEDER/UE)” and has received funding from Generalitat de Cataluña 2017 SGR 1426., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effect of channel thickness on noise in organic electrochemical transistors

  • Polyravas, Anastasios G.
  • Schäfer, Nathan
  • Curto, Vincenzo F.
  • Bonaccini Calia, Andrea
  • Guimerà-Brunet, Anton
  • Garrido, Jose A.
  • Malliaras, George G.
Organic electrochemical transistors (OECTs) have been widely used as transducers in electrophysiology and other biosensing applications. Their identifying characteristic is a transconductance that increases with channel thickness, and this provides a facile mechanism to achieve high signal amplification. However, little is known about their noise behavior. Here, we investigate noise and extract metrics for the signal-to-noise ratio and limit of detection in OECTs with different channel thicknesses. These metrics are shown to improve as the channel thickness increases, demonstrating that OECTs can be easily optimized to show not only high amplification, but also low noise., This work was funded by the European Union's Horizon 2020 research and innovation programme under Grant Agreement No. 732032 (BrainCom) the King Abdullah University of Science and Technology (KAUST) Office of sponsored Research (OSR) under Award No. OSR-2016-CRG5-3003. Authors also acknowledge funding from the 2DTecBio (FIS2017-85787-R) funded by the Spanish Ministry of Science, Innovation and Universities, the State Research Agency (AEI), and the European Regional Development Fund., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Self-Pixelation Through Fracture in VO2 Thin Films

  • Rodríguez, Laura
  • Del Corro, Elena
  • Conroy, Michele
  • Moore, Kalani
  • Sandiumenge, Felip
  • Domingo, Neus
  • Santiso, José
  • Catalán, Gustau
Vanadium dioxide (VO2) is an archetypal Mott material with a metal–insulator transition (MIT) at near room temperature. In thin films, this transition is affected by substrate-induced strain but as film thickness increases, the strain is gradually relaxed and the bulk properties are recovered. Epitaxial films of VO2 on (001)-oriented rutile titanium dioxide (TiO2) relax substrate strain by forming a network of fracture lines that crisscross the film along well-defined crystallographic directions. This work shows that the electronic properties associated with these lines result in a pattern that resembles a “street map” of fully strained metallic VO2 blocks separated by insulating VO2 stripes. Each block of VO2 is thus electronically self-insulated from its neighbors, and its MIT can be locally induced optically with a laser, or electronically via the tip of a scanning probe microscope so that the films behave functionally as self-patterned pixel arrays., This work was supported from the Spanish Ministry of Economy, Industry and Competitiveness (project: MAT2016- 77100-C2-1-P), the Catalan AGAUR agency for 2017SGR, and the Science Foundation Ireland (SFI 16/US/3344). ICN2 is funded by the CERCA programme/Generalitat de Catalunya and the Severo Ochoa programme (SEV-2017-0706). L.R. particularly acknowledges the support of the Severo Ochoa program and ICN2 for her Ph.D. grant. E.d.C. acknowledges the Spanish “Juan de la Cierva” grant (JC-2015-25201) and the research project FIS2017-85787. M.C. acknowledges funding from SFI Industry Fellowship (18/IF/6282)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Graphene active sensor arrays for long-term and wireless mapping of wide frequency band epicortical brain activity

  • Garcia Cortadella, Ramon
  • Schwesig, Gerrit
  • Jeschke, Christoph
  • Illa, Xavi
  • Gray, Anna L.
  • Savage, Sinead
  • Stamatidou, E.
  • Schiessl, I.
  • Masvidal Codina, Eduard
  • Kostarelos, Kostas
  • Guimerà-Brunet, Anton
  • Sirota, Anton
  • Garrido, Jose A.
Graphene active sensors have demonstrated promising capabilities for the detection of electrophysiological signals in the brain. Their functional properties, together with their flexibility as well as their expected stability and biocompatibility have raised them as a promising building block for large-scale sensing neural interfaces. However, in order to provide reliable tools for neuroscience and biomedical engineering applications, the maturity of this technology must be thoroughly studied. Here, we evaluate the performance of 64-channel graphene sensor arrays in terms of homogeneity, sensitivity and stability using a wireless, quasi-commercial headstage and demonstrate the biocompatibility of epicortical graphene chronic implants. Furthermore, to illustrate the potential of the technology to detect cortical signals from infra-slow to high-gamma frequency bands, we perform proof-of-concept long-term wireless recording in a freely behaving rodent. Our work demonstrates the maturity of the graphene-based technology, which represents a promising candidate for chronic, wide frequency band neural sensing interfaces., This work has been funded by the European Union’s Horizon 2020 research and innovation program under Grant Agreement No. 732032 (BrainCom) and Graphene Flagship Grant Agreements No. 785219 (GrapheneCore2) and 881603 (GrapheneCore3). The ICN2 is supported by the Severo Ochoa Centres of Excellence program, funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706), and by the CERCA Program/Generalitat de Catalunya. R.G.C. is supported by the International Ph.D Program La Caixa-Severo Ochoa (Programa Internacional de Becas “la Caixa”-Severo Ochoa). This work has made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS “NANBIOSIS”, more specifically by the Micro-NanoTechnology Unit of the CIBER in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN) at the IMB-CNM. This work is within the project FIS2017-85787-R funded by the “Ministerio de Ciencia, Innovación y Universidades” of Spain, the “Agencia Estatal de Investigación (AEI)”, and the “Fondo Europeo de Desarrollo Regional (FEDER/UE)”. A.S. and G.S. were also supported by Bundesministerium für Bildung und Forschung [grant number 01GQ0440]. R.G.C. acknowledges that this work has been done in the framework of the Ph.D in Electrical and Telecommunication Engineering at the Universitat Autònoma de Barcelona.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Heat dissipation in few-layer MoS2and MoS2/hBN heterostructure

  • Arrighi, Aloïs
  • Del Corro, Elena
  • Navarro-Urrios, D.
  • Costache, Marius V.
  • Sierra, Juan F.
  • Watanabe, Kenji
  • Taniguchi, Takashi
  • Garrido, Jose A.
  • Valenzuela, Sergio O.
  • Sotomayor Torres, C. M.
  • Sledzinska, Marianna
State-of-the-art fabrication and characterisation techniques have been employed to measure the thermal conductivity of suspended, single-crystalline MoS2 and MoS2/hBN heterostructures. Two-laser Raman scattering thermometry was used combined with real time measurements of the absorbed laser power. Measurements on MoS2 layers with thicknesses of 5 and 14 nm exhibit thermal conductivity in the range between 12 Wm-1 K-1 and 24 Wm-1 K-1. Additionally, after determining the thermal conductivity of the latter MoS2 sample, an hBN flake was transferred onto it and the effective thermal conductivity of the heterostructure was subsequently measured. Remarkably, despite that the thickness of the hBN layer was less than a hal of the thickness of the MoS2 layer, the heterostructure showed an almost eight-fold increase in the thermal conductivity, being able to dissipate more than ten times the laser power without any visible sign of damage. These results are consistent with a high thermal interface conductance G between MoS2 and hBN and an efficient in-plane heat spreading driven by hBN. Indeed, we estimate G ∼ 70 MW m-2 K-1 for hBN layer thermal conductivity of 450 Wm-1 K-1 which is significantly higher than previously reported values. Our work therefore demonstrates that the insertion of hBN layers in potential MoS2-based devices holds the promise for efficient thermal management., This work was partially funded by the European Union under the H2020 FET-OPEN NANOPOLY (GA 289061) and Spanish Ministry of Science projects SIP (PGC2018-101743-B-I00), ADAGIO (PGC2018-094490-B-C22), 2DTecBio (FIS2017-85787-R) and 2DENGINE (PID2019-111773RB- I00/AEI/10.13039/501100011033). E D C acknowledges the Spanish Ministry of Science for the Juan de la Cierva Fellowship (JC-2015-25201) and the Ramon y Cajal fellowship (RYC2019-027879-I). D N U and J F S acknowledge the Ramón y Cajal fellowships RYC2014-15392 and RYC2019-028368-I/AEI/10.13039/501100011033. M V C acknowledges project (Reference No. 103739) funded by the Agencia Estatal de Investigación through the PCI 2019 call. The Catalan Institute of Nanoscience and Nanotechnology (ICN2) is funded by the CERCA program/Generalitat de Catalunya, and is supported by the Severo Ochoa program from Spanish MINECO (Grant No. SEV-2017-0706). K W and T T acknowledge support from the Elemental Strategy Initiative conducted by the MEXT, Japan (Grant Number JPMXP0112101001) and JSPS KAKENHI (Grant Numbers 19H05790 and JP20H00354).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Single and Multisite Graphene-Based Electroretinography Recording Electrodes: A Benchmarking Study

  • Cruz, José P. de la
  • Nguyen, Diep
  • Illa, Xavi
  • Bousquet, Jessica
  • Pérez-Marín, Antonio Pablo
  • Del Corro, Elena
  • Picaud, Serge
  • Garrido, Jose A.
  • Hébert, Clement
Electroretinography (ERG) is a clinical test employed to understand and diagnose many retinopathies. ERG is usually performed by placing a macroscopic ring gold wire electrode on the cornea while flashing light onto the eye to measure changes in the transretinal potential. However, macroscopic gold electrodes are severely limiting since they do not provide a flexible interface to contact the sensitive corneal tissue, making this technique highly uncomfortable for the patient. Another major drawback is the opacity of gold electrodes, which only allows them to record the ERG signal on the corneal periphery, preventing central ERG recordings. To overcome the limitations of metal-based macroscopic ERG electrodes, flexible electrodes are fabricated using graphene as a transparent, flexible, and sensitive material. The transparency of the graphene is exploited to fabricate microelectrode arrays (MEAs) that are able to perform multisite recording on the cornea. The graphene-based ERG electrodes are benchmarked against the widely used gold electrodes in a P23H rat model with photoreceptor degeneration. This study shows that the graphene-based ERG electrodes can faithfully record ERGs under a wide range of conditions (light intensity, stage of photoreceptor degeneration, etc.) while offering additional benefits for ERG recordings such as transparency and flexibility., J.d.l.C. and D.N. contributed equally to this work. This project received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement nos. 881603 (GrapheneCore3). This work was within the project FIS2017-85787-R funded by the “Ministerio de Ciencia, Innovación y Universidades” of Spain, the “Agencia Estatal de Investigación (AEI),” and the “Fondo Europeo de Desarrollo Regional (FEDER/UE).” Support was also provided by the French state funds managed by the Agence Nationale de la Recherche within the Programme Investissements d'Avenir, LABEX LIFESENSES (ANR-10-LABX-65) and IHU FOReSIGHT (ANR-18-IAHU-0001). The ICN2 is supported by the Severo Ochoa Centres of Excellence program, funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706), and by the CERCAProgram/Generalitat de Catalunya. E.d.C. acknowledges the Spanish MINECO Juan de la Cierva Fellowship JC-2015-25201. This work made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS “NANBIOSIS,” more specifically by the Micro-NanoTechnology Unit of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) at the IMB-CNM. J.d.l.C. would like to thank Laura García for the work on the images and figures throughout the whole paper writing process. E.d.C acknowledges the grant RYC2019-027879-I financed by MCIN/AEI /10.13039/501100011033. The project leading to these results have received funding from “la Caixa” Foundation (ID 100010434), under the agreement LCF/PR/HR19/52160003. These activities are co-funded with 50% by the European Regional Development Fund under the framework of the ERFD Operative Programme for Catalunya 2014–2020 with the support of the Department de Recerca i Universitat (GraphCAT 001-P-001702).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Full-bandwidth electrophysiology of seizures and epileptiform activity enabled by flexible graphene microtransistor depth neural probes

  • Bonaccini Calia, Andrea
  • Masvidal Codina, Eduard
  • Smith, Trevor M.
  • Schäfer, Nathan
  • Rathore, Daman
  • Rodríguez-Lucas, Elisa
  • Illa, Xavi
  • Cruz, Jose Manuel de la
  • Del Corro, Elena
  • Prats Alfonso, Elisabet
  • Viana, Damià
  • Bousquet, Jessica
  • Hébert, Clement
  • Martínez Aguilar, Javier
  • Sperling, Justin R.
  • Drummond, Matthew
  • Halder, Arnab
  • Dodd, Abbie
  • Barr, Katharine
  • Savage, Sinead
  • Fornell, Jordina
  • Sort, Jordi
  • Guger, Christoph
  • Villa, Rosa
  • Kostarelos, Kostas
  • Wykes, Rob C.
  • Guimerà-Brunet, Anton
  • Garrido, Jose A.
Mapping the entire frequency bandwidth of brain electrophysiological signals is of paramount importance for understanding physiological and pathological states. The ability to record simultaneously DC-shifts, infraslow oscillations (<0.1 Hz), typical local field potentials (0.1–80 Hz) and higher frequencies (80–600 Hz) using the same recording site would particularly benefit preclinical epilepsy research and could provide clinical biomarkers for improved seizure onset zone delineation. However, commonly used metal microelectrode technology suffers from instabilities that hamper the high fidelity of DC-coupled recordings, which are needed to access signals of very low frequency. In this study we used flexible graphene depth neural probes (gDNPs), consisting of a linear array of graphene microtransistors, to concurrently record DC-shifts and high-frequency neuronal activity in awake rodents. We show here that gDNPs can reliably record and map with high spatial resolution seizures, pre-ictal DC-shifts and seizure-associated spreading depolarizations together with higher frequencies through the cortical laminae to the hippocampus in a mouse model of chemically induced seizures. Moreover, we demonstrate the functionality of chronically implanted devices over 10 weeks by recording with high fidelity spontaneous spike-wave discharges and associated infraslow oscillations in a rat model of absence epilepsy. Altogether, our work highlights the suitability of this technology for in vivo electrophysiology research, and in particular epilepsy research, by allowing stable and chronic DC-coupled recordings., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 881603 (GrapheneCore3). ICN2 is supported by the Severo Ochoa Centres of Excellence programme, funded by the Spanish Research Agency (AEI, grant no. SEV-2017–0706), and by the CERCA Programme/Generalitat de Catalunya. A.B.C. is supported by the International PhD Programme La Caixa-Severo Ochoa (Programa Internacional de Becas ‘la Caixa’-Severo Ochoa). This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) at the IMB-CNM. We also acknowledge funding from the Generalitat de Catalunya (2017 SGR 1426), and the 2DTecBio project (FIS2017-85787-R) funded by the Ministerio de Ciencia, Innovación y Universidades of Spain, the Agencia Estatal de Investigación (AEI) and the Fondo Europeo de Desarrollo Regional (FEDER/UE). Part of this work was co-funded by the European Regional Development Funds (ERDF) allocated to the Programa operatiu FEDER de Catalunya 2014–2020, with the support of the Secretaria d’Universitats i Recerca of the Departament d’Empresa i Coneixement of the Generalitat de Catalunya for emerging technology clusters devoted to the valorization and transfer of research results (GraphCAT 001-P-001702). A.B.C. acknowledges that this work has been carried out within the framework of a PhD in Electrical and Telecommunication Engineering at the Universitat Autònoma de Barcelona. R.C.W. is funded by a Senior Research Fellowship awarded by the Worshipful Company of Pewterers. D.R. is a Biotechnology and Biological Sciences Research Council (BBSRC) LIDo sponsored PhD student. We thank M. Walker and L. Lemieux (UCL Queen Square Institute of Neurology) for their comments on the manuscript., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Improved metal-graphene contacts for low-noise, high-density microtransistor arrays for neural sensing

  • Schaefer, Nathan
  • Garcia-Cortadella, Ramon
  • Calia, Andrea Bonaccini
  • Mavredakis, Nikolaos
  • Illa, Xavi
  • Masvidal Codina, Eduard
  • Cruz, Jose de la
  • Corro, Elena del
  • Rodríguez, Laura
  • Prats-Alfonso, Elisabet
  • Bousquet, Jessica
  • Martínez-Aguilar, Javier
  • Pérez-Marín, Antonio P.
  • Hébert, Clement
  • Villa, Rosa
  • Jiménez, David
  • Guimerà-Brunet, Anton
  • Garrido, Jose A.
Poor metal contact interfaces are one of the main limitations preventing unhampered access to the full potential of two-dimensional materials in electronics. Here we present graphene solution-gated field-effect-transistors (gSGFETs) with strongly improved linearity, homogeneity and sensitivity for small sensor sizes, resulting from ultraviolet ozone (UVO) contact treatment. The contribution of channel and contact region to the total device conductivity and flicker noise is explored experimentally and explained with a theoretical model. Finally, in-vitro recordings of flexible microelectrocorticography (μ-ECoG) probes were performed to validate the superior sensitivity of the UVO-treated gSGFET to brain-like activity. These results connote an important step towards the fabrication of high-density gSGFET μ-ECoG arrays with state-of-the-art sensitivity and homogeneity, thus demonstrating the potential of this technology as a versatile platform for the new generation of neural interfaces., Funding text 1 D.J. and N.M. also acknowledge financial support by Spain’s Ministerio de Ciencia, Innovación y Universidades under Grant No. RTI2018-097876-B-C21 ( MCIU/AEI/FEDER, UE ). Funding text 2 This work has made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) at the IMB-CNM. Funding text 3 The authors wish to thank Narcís Mestres-Andreu (ICMAB-Institut de Ciència de Materials de Barcelona) for giving us access to the ultraviolet ozone cleaner. This work has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreements Nº 785219 (Graphene Flagship Core Project 2) and Nº 732032 (BrainCom). We also acknowledge funding from Generalitat de Catalunya 2017 SGR 1426, and the 2DTecBio (FIS2017-85787-R) funded by Ministry of Science, Innovation and Universities, the State Research Agency (AEI) and the European Regional Development Fund (FEDER/UE). The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706), and is funded by the CERCA programme/Generalitat de Catalunya. R.G.C. and A.B.C. are supported by the International PhD Programme La Caixa - Severo Ochoa (Programa Internacional de Becas “la Caixa"-Severo Ochoa). EDC acknowledges the Spanish MINECO Juan de la Cierva Fellowship JC-2015-25201. D.J. and N.M. also acknowledge financial support by Spain's Ministerio de Ciencia, Innovación y Universidades under Grant No. RTI2018-097876-B-C21 (MCIU/AEI/FEDER, UE). This work has made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) at the IMB-CNM. Funding text 4 This work has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreements Nº 785219 (Graphene Flagship Core Project 2) and Nº 732032 (BrainCom). We also acknowledge funding from Generalitat de Catalunya 2017 SGR 1426 , and the 2DTecBio ( FIS2017-85787-R ) funded by Ministry of Science, Innovation and Universities, the State Research Agency (AEI) and the European Regional Development Fund (FEDER/UE) . The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, funded by the Spanish Research Agency (AEI , grant no. SEV-2017-0706 ), and is funded by the CERCA programme/Generalitat de Catalunya. R.G.C. and A.B.C. are supported by the International PhD Programme La Caixa - Severo Ochoa (Programa Internacional de Becas “la Caixa"-Severo Ochoa). EDC acknowledges the Spanish MINECO Juan de la Cierva Fellowship JC-2015-25201 ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Distortion-Free Sensing of Neural Activity Using Graphene Transistors

  • Garcia-Cortadella, Ramon
  • Masvidal Codina, Eduard
  • De la Cruz, Jose M
  • Schäfer, Nathan
  • Schwesig, Gerrit
  • Jeschke, Christoph
  • Martinez-Aguilar, Javier
  • Sanchez-Vives, Maria V
  • Villa, Rosa
  • Illa, Xavi
  • Sirota, Anton
  • Guimerà, Anton
  • Garrido, Jose A
Graphene solution-gated field-effect transistors (g-SGFETs) are promising sensing devices to transduce electrochemical potential signals in an electrolyte bath. However, distortion mechanisms in g-SGFET, which can affect signals of large amplitude or high frequency, have not been evaluated. Here, a detailed characterization and modeling of the harmonic distortion and non-ideal frequency response in g-SGFETs is presented. This accurate description of the input-output relation of the g-SGFETs allows to define the voltage- and frequency-dependent transfer functions, which can be used to correct distortions in the transduced signals. The effect of signal distortion and its subsequent calibration are shown for different types of electrophysiological signals, spanning from large amplitude and low frequency cortical spreading depression events to low amplitude and high frequency action potentials. The thorough description of the distortion mechanisms presented in this article demonstrates that g-SGFETs can be used as distortion-free signal transducers not only for neural sensing, but also for a broader range of applications in which g-SGFET sensors are used., This work had been funded by the European Union's Horizon 2020 research and innovation programme under Grant Agreement No. 785219 (Graphene Flagship) and Grant Agreement No. 732032 (BrainCom). The authors also acknowledge funding form Generalitat de Catalunya 2017 SGR 1426, and the 2DTecBio (FIS2017‐85787‐R) funded by the Spanish Ministry of Science, Innovation and Universities, the State Research Agency (AEI), and the European Regional Development Fund. The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, funded by the Spanish Research Agency (AEI, grant no. SEV‐2017‐0706), and by the CERCA Programme/Generalitat de Catalunya. R.G.C. acknowledges that this work had been done in the framework of the Ph.D. in Electrical and Telecommunication Engineering at the Universitat Autònoma de Barcelona. R.G.C. was supported by the International PhD Programme La Caixa—Severo Ochoa (Programa Internacional de Becas “la Caixa”‐Severo Ochoa). This work made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS “NANBIOSIS”, more specifically by the Micro‐NanoTechnology Unit of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER‐BBN) at the IMB‐CNM., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Switchless multiplexing of graphene active sensor arrays for brain mapping

  • Garcia Cortadella, Ramon|||0000-0002-1506-6534
  • Schaefer, Nathan|||0000-0002-2392-3858
  • Cisneros-Fernández, Jose|||0000-0002-5497-7103
  • Ré, Lucia
  • Illa, Xavi|||0000-0002-3212-1128
  • Schwesig, Gerrit
  • Moya Lara, Ana|||0000-0001-6793-9133
  • Santiago Malagon, Sara|||0000-0002-1206-1455
  • Guirado, Gonzalo|||0000-0003-2128-7007
  • Villa, Rosa|||0000-0003-2735-3204
  • Sirota, Anton|||0000-0002-4700-6587
  • Serra Graells, Francesc|||0000-0002-7274-1911
  • Garrido, Jose|||0000-0001-5621-1067
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
Sensor arrays used to detect electrophysiological signals from the brain are paramount in neuroscience. However, the number of sensors that can be interfaced with macroscopic data acquisition systems currently limits their bandwidth. This bottleneck originates in the fact that, typically, sensors are addressed individually, requiring a connection for each of them. Herein, we present the concept of frequency-division multiplexing (FDM) of neural signals by graphene sensors. We demonstrate the high performance of graphene transistors as mixers to perform amplitude modulation (AM) of neural signals in situ, which is used to transmit multiple signals through a shared metal line. This technology eliminates the need for switches, remarkably simplifying the technical complexity of state-of-the-art multiplexed neural probes. Besides, the scalability of FDM graphene neural probes has been thoroughly evaluated and their sensitivity demonstrated in vivo. Using this technology, we envision a new generation of high-count conformal neural probes for high bandwidth brain machine interfaces.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Distortion-free sensing of neural activity using graphene transistors

  • Garcia Cortadella, Ramon|||0000-0002-1506-6534
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • De la Cruz, Jose|||0000-0001-9656-9653
  • Schaefer, Nathan|||0000-0002-2392-3858
  • Schwesig, Gerrit
  • Jeschke, C.
  • Martínez-Aguilar, Javier
  • Sánchez Vives, María V.|||0000-0002-8437-9083
  • Villa, Rosa|||0000-0003-2735-3204
  • Illa, Xavi|||0000-0002-3212-1128
  • Sirota, Anton|||0000-0002-4700-6587
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Garrido, Jose|||0000-0001-5621-1067
Graphene solution-gated field-effect transistors (g-SGFETs) are promising sensing devices to transduce electrochemical potential signals in an electrolyte bath. However, distortion mechanisms in g-SGFET, which can affect signals of large amplitude or high frequency, have not been evaluated. Here, a detailed characterization and modeling of the harmonic distortion and non-ideal frequency response in g-SGFETs is presented. This accurate description of the input-output relation of the g-SGFETs allows to define the voltage- and frequency-dependent transfer functions, which can be used to correct distortions in the transduced signals. The effect of signal distortion and its subsequent calibration are shown for different types of electrophysiological signals, spanning from large amplitude and low frequency cortical spreading depression events to low amplitude and high frequency action potentials. The thorough description of the distortion mechanisms presented in this article demonstrates that g-SGFETs can be used as distortion-free signal transducers not only for neural sensing, but also for a broader range of applications in which g-SGFET sensors are used.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Multiplexed neural sensor array of graphene solution-gated field-effect transistors

  • Schaefer, Nathan|||0000-0002-2392-3858
  • Garcia Cortadella, Ramon|||0000-0002-1506-6534
  • Martínez-Aguilar, Javier
  • Schwesig, Gerrit
  • Illa, Xavi|||0000-0002-3212-1128
  • Moya Lara, Ana|||0000-0001-6793-9133
  • Santiago Malagon, Sara|||0000-0002-1206-1455
  • Hébert, Clément|||0000-0001-9667-033X
  • Guirado, Gonzalo|||0000-0003-2128-7007
  • Villa, Rosa|||0000-0003-2735-3204
  • Sirota, Anton|||0000-0002-4700-6587
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Garrido, Jose|||0000-0001-5621-1067
Electrocorticography (ECoG) is a well-established technique to monitor electrophysiological activity from the surface of the brain and has proved crucial for the current generation of neural prostheses and brain-computer interfaces. However, existing ECoG technologies still fail to provide the resolution necessary to accurately map highly localized activity across large brain areas, due to the rapidly increasing size of connector footprint with sensor count. This work demonstrates the use of a flexible array of graphene solution-gated field-effect transistors (gSGFET), exploring the concept of multiplexed readout using an external switching matrix. This approach does not only allow for an increased sensor count, but due to the use of active sensing devices (i.e. transistors) over microelectrodes it makes additional buffer transistors redundant, which drastically eases the complexity of device fabrication on flexible substrates. The presented results pave the way for upscaling the gSGFET technology towards large-scale, high-density μECoG-arrays, eventually capable of resolving neural activity down to a single neuron level, while simultaneously mapping large brain regions.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Improved metal-graphene contacts for low-noise, high-density microtransistor arrays for neural sensing

  • Schaefer, Nathan|||0000-0002-2392-3858
  • Garcia Cortadella, Ramon|||0000-0002-1506-6534
  • Bonaccini Calia, Andrea|||0000-0002-7873-4296
  • Mavredakis, Nikolaos|||0000-0003-3630-9416
  • Illa, Xavi|||0000-0002-3212-1128
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • De la Cruz, Jose|||0000-0001-9656-9653
  • Del Corro, Elena|||0000-0001-6452-9139
  • Rodríguez Domínguez, Laura|||0000-0002-6669-1962
  • Prats Alfonso, Elisabet|||0000-0002-7320-1896
  • Bousquet, Jessica|||0000-0001-5721-8092
  • Martínez-Aguilar, Javier
  • Pérez-Marín, Antonio Pablo|||0000-0003-1843-8273
  • Hébert, Clément|||0000-0001-9667-033X
  • Villa, Rosa|||0000-0003-2735-3204
  • Jiménez, David|||0000-0002-8148-198X
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Garrido, Jose|||0000-0001-5621-1067
Poor metal contact interfaces are one of the main limitations preventing unhampered access to the full potential of two-dimensional materials in electronics. Here we present graphene solution-gated field-effect-transistors (gSGFETs) with strongly improved linearity, homogeneity and sensitivity for small sensor sizes, resulting from ultraviolet ozone (UVO) contact treatment. The contribution of channel and contact region to the total device conductivity and flicker noise is explored experimentally and explained with a theoretical model. Finally, in-vitro recordings of flexible microelectrocorticography (μ-ECoG) probes were performed to validate the superior sensitivity of the UVO-treated gSGFET to brain-like activity. These results connote an important step towards the fabrication of high-density gSGFET μ-ECoG arrays with state-of-the-art sensitivity and homogeneity, thus demonstrating the potential of this technology as a versatile platform for the new generation of neural interfaces.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Effect of channel thickness on noise in organic electrochemical transistors

  • Polyravas, Anastasios G.|||0000-0003-1620-5310
  • Schaefer, Nathan|||0000-0002-2392-3858
  • Curto, Vicenzo Fabio|||0000-0002-0571-7903
  • Bonaccini Calia, Andrea|||0000-0002-7873-4296
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Garrido, Jose|||0000-0001-5621-1067
  • Malliaras, George|||0000-0002-4582-8501
Organic electrochemical transistors (OECTs) have been widely used as transducers in electrophysiology and other biosensing applications. Their identifying characteristic is a transconductance that increases with channel thickness, and this provides a facile mechanism to achieve high signal amplification. However, little is known about their noise behavior. Here, we investigate noise and extract metrics for the signal-to-noise ratio and limit of detection in OECTs with different channel thicknesses. These metrics are shown to improve as the channel thickness increases, demonstrating that OECTs can be easily optimized to show not only high amplification, but also low noise.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Graphene active sensor arrays for long-term and wireless mapping of wide frequency band epicortical brain activity

  • Garcia Cortadella, Ramon|||0000-0002-1506-6534
  • Schwesig, Gerrit
  • Jeschke, Christoph
  • Illa, Xavi|||0000-0002-3212-1128
  • Gray, Anna L.
  • Savage, Sinead|||0000-0002-1761-9390
  • Stamatidou, Emmanouela
  • Schiessl, Ingo|||0000-0001-9599-6194
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Kostarelos, Kostas|||0000-0002-2224-6672
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Sirota, Anton|||0000-0002-4700-6587
  • Garrido, Jose|||0000-0001-5621-1067
Graphene active sensors have demonstrated promising capabilities for the detection of electrophysiological signals in the brain. Their functional properties, together with their flexibility as well as their expected stability and biocompatibility have raised them as a promising building block for large-scale sensing neural interfaces. However, in order to provide reliable tools for neuroscience and biomedical engineering applications, the maturity of this technology must be thoroughly studied. Here, we evaluate the performance of 64-channel graphene sensor arrays in terms of homogeneity, sensitivity and stability using a wireless, quasi-commercial headstage and demonstrate the biocompatibility of epicortical graphene chronic implants. Furthermore, to illustrate the potential of the technology to detect cortical signals from infra-slow to high-gamma frequency bands, we perform proof-of-concept long-term wireless recording in a freely behaving rodent. Our work demonstrates the maturity of the graphene-based technology, which represents a promising candidate for chronic, wide frequency band neural sensing interfaces.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Self-pixelation through fracture in VO2 thin films

  • Rodríguez Domínguez, Laura|||0000-0002-6669-1962
  • Del Corro, Elena|||0000-0001-6452-9139
  • Conroy, Michele
  • Moore, Kalani
  • Sandiumenge Ortiz, Felip|||0000-0003-1336-1529
  • Domingo Marimon, Neus|||0000-0002-5229-6638
  • Santiso, José|||0000-0003-4274-2101
  • Catalan, Gustau|||0000-0003-0214-4828
Vanadium dioxide (VO2) is an archetypal Mott material with a metal-insulator transition (MIT) at near room temperature. In thin films, this transition is affected by substrate-induced strain but as film thickness increases, the strain is gradually relaxed and the bulk properties are recovered. Epitaxial films of VO2 on (001)-oriented rutile titanium dioxide (TiO2) relax substrate strain by forming a network of fracture lines that crisscross the film along well-defined crystallographic directions. This work shows that the electronic properties associated with these lines result in a pattern that resembles a "street map" of fully strained metallic VO2 blocks separated by insulating VO2 stripes. Each block of VO2 is thus electronically self-insulated from its neighbors, and its MIT can be locally induced optically with a laser, or electronically via the tip of a scanning probe microscope so that the films behave functionally as self-patterned pixel arrays.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Characterization of optogenetically-induced cortical spreading depression in awake mice using graphene micro-transistor arrays

  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Smith, Trevor M.|||0000-0002-5495-8906
  • Rathore, Daman
  • Gao, Yunan|||0000-0003-1228-1252
  • Illa, Xavi|||0000-0002-3212-1128
  • Prats-Alfonso, Elisabet
  • Del Corro, Elena|||0000-0001-6452-9139
  • Bonaccini Calia, Andrea|||0000-0002-7873-4296
  • Rius, Gemma|||0000-0003-0552-1043
  • Martín Fernández, Iñigo|||0000-0001-5388-8611
  • Guger, Christoph
  • Reitner, Patrick
  • Villa, Rosa|||0000-0003-2735-3204
  • Garrido, Jose|||0000-0001-5621-1067
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Wykes, Robert C.|||0000-0002-6141-6822
Objective. The development of experimental methodology utilizing graphene micro-transistor arrays to facilitate and advance translational research into cortical spreading depression (CSD) in the awake brain. Approach. CSDs were reliably induced in awake nontransgenic mice using optogenetic methods. High-fidelity DC-coupled electrophysiological mapping of propagating CSDs was obtained using flexible arrays of graphene soultion-gated field-effect transistors (gSGFETs). Main results. Viral vectors targetted channelrhopsin expression in neurons of the motor cortex resulting in a transduction volume 1 mm3. 5-10 s of continous blue light stimulation induced CSD that propagated across the cortex at a velocity of 3.0 0.1 mm min-1. Graphene micro-transistor arrays enabled high-density mapping of infraslow activity correlated with neuronal activity suppression across multiple frequency bands during both CSD initiation and propagation. Localized differences in the CSD waveform could be detected and categorized into distinct clusters demonstrating the spatial resolution advantages of DC-coupled recordings. We exploited the reliable and repeatable induction of CSDs using this preparation to perform proof-of-principle pharmacological interrogation studies using NMDA antagonists. MK801 (3 mg kg-1) suppressed CSD induction and propagation, an effect mirrored, albeit transiently, by ketamine (15 mg kg-1), thus demonstrating this models' applicability as a preclinical drug screening platform. Finally, we report that CSDs could be detected through the skull using graphene micro-transistors, highlighting additional advantages and future applications of this technology. Significance. CSD is thought to contribute to the pathophysiology of several neurological diseases. CSD research will benefit from technological advances that permit high density electrophysiological mapping of the CSD waveform and propagation across the cortex. We report an in vivo assay that permits minimally invasive optogenetic induction, combined with multichannel DC-coupled recordings enabled by gSGFETs in the awake brain. Adoption of this technological approach could facilitate and transform preclinical investigations of CSD in disease relevant models.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Carbon incorporation in MOCVD of MoS2 thin films grown from an organosulfide precursor

  • Schaefer, Christian M.|||0000-0001-7994-2962
  • Caicedo Roque, Jose Manuel|||0000-0002-5192-4989
  • Sauthier, Guillaume|||0000-0003-3566-3878
  • Bousquet, Jessica|||0000-0001-5721-8092
  • Hébert, Clément|||0000-0001-9667-033X
  • Sperling, Justin R.|||0000-0002-1708-2474
  • Perez-Tomas, Amador|||0000-0002-0551-3142
  • Santiso, José|||0000-0003-4274-2101
  • Del Corro, Elena|||0000-0001-6452-9139
  • Garrido, Jose|||0000-0001-5621-1067
With the rise of two-dimensional (2D) transition-metal dichalcogenide (TMD) semiconductors and their prospective use in commercial (opto)electronic applications, it has become key to develop scalable and reliable TMD synthesis methods with well-monitored and controlled levels of impurities. While metal-organic chemical vapor deposition (MOCVD) has emerged as the method of choice for large-scale TMD fabrication, carbon (C) incorporation arising during MOCVD growth of TMDs has been a persistent concern-especially in instances where organic chalcogen precursors are desired as a less hazardous alternative to more toxic chalcogen hydrides. However, the underlying mechanisms of such unintentional C incorporation and the effects on film growth and properties are still elusive. Here, we report on the role of C-containing side products of organosulfur precursor pyrolysis in MoS2 thin films grown from molybdenum hexacarbonyl Mo(CO)6 and diethyl sulfide (CH3CH2)2S (DES). By combining in situ gas-phase monitoring with ex situ microscopy and spectroscopy analyses, we systematically investigate the effect of temperature and Mo(CO)6/DES/H2 gas mixture ratios on film morphology, chemical composition, and stoichiometry. Aiming at high-quality TMD growth that typically requires elevated growth temperatures and high DES/Mo(CO)6 precursor ratios, we observed that temperatures above DES pyrolysis onset (â 600 °C) and excessive DES flow result in the formation of nanographitic carbon, competing with MoS2 growth. We found that by introducing H2 gas to the process, DES pyrolysis is significantly hindered, which reduces carbon incorporation. The C content in the MoS2 films is shown to quench the MoS2 photoluminescence and influence the trion-To-exciton ratio via charge transfer. This finding is fundamental for understanding process-induced C impurity doping in MOCVD-grown 2D semiconductors and might have important implications for the functionality and performance of (opto)electronic devices.
Dipòsit Digital de Documents de la UAB
Publicación Artículo preliminar (WorkingPaper)

Heat dissipation in few-layer MoS2 and MoS2/hBN heterostructure

  • Arrighi, Aloïs|||0000-0002-9774-852X
  • Del Corro, Elena|||0000-0001-6452-9139
  • Navarro Urrios, Daniel|||0000-0001-9055-1583
  • Costache, Marius Vasile|||0000-0001-7432-6175
  • Sierra, Juan F.|||0000-0002-5438-0534
  • Watanabe, Kenji|||0000-0003-3701-8119
  • Taniguchi, Takashi|||0000-0002-1467-3105
  • Garrido, Jose|||0000-0001-5621-1067
  • Valenzuela, Sergio O.|||0000-0002-4632-8891
  • Sotomayor Torres, Clivia M.|||0000-0001-9986-2716
  • Sledzinska, Marianna|||0000-0001-8592-1121
State-of-the-art fabrication and characterization techniques have been employed to measure the thermal conductivity of suspended, single-crystalline MoS2 and MoS2/hBN heterostructures. Two-laser Raman scattering thermometry was used combined with real time measurements of the absorbed laser power, which allowed us to determine the thermal conductivities without any assumptions. Measurements on MoS2 layers with thicknesses of 5 and 14 exhibit thermal conductivity in the range between 12 and 24 Wm-1K-1. Additionally, after determining the thermal conductivity of a selected MoS2 sample, an hBN flake was transferred onto it and the effective thermal conductivity of the heterostructure was subsequently measured. Remarkably, despite that the thickness of the hBN layer was less than a third of the thickness of the MoS2 layer, the heterostructure showed an almost eight-fold increase in the thermal conductivity, being able to dissipate more than 10 times the laser power without any visible sign of damage. These results are consistent with a high thermal interface conductance between MoS2 and hBN and an efficient in-plane heat spreading driven by hBN. Indeed, we estimate G 70 MWm-2K-1 which is significantly higher than previously reported values. Our work therefore demonstrates that the insertion of hBN layers in potential MoS2 based devices holds the promise for efficient thermal management.