Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Automatic detection of slow conducting channels during substrate ablation of scar-related ventricular arrhythmias

  • Alcaine, Alejandro
  • Jáuregui, Beatriz
  • Soto-Iglesias, David
  • Acosta, Juan
  • Penela, Diego
  • Fernández-Armenta, Juan
  • Linhart, Markus
  • Andreu, David
  • Mont, Lluis
  • Laguna, Pablo
  • Cámara, Óscar
  • Martínez, Juan Pablo
  • Berruezo, Antonio
Background. Voltage mapping allows identifying the arrhythmogenic substrate during scar-related ventricular arrhythmia (VA) ablation procedures. Slow conducting channels (SCCs), defined by the presence of electrogram (EGM) signals with delayed components (EGM-DC), are responsible for sustaining VAs and constitute potential ablation targets. However, voltage mapping, as it is currently performed, is time-consuming, requiring a manual analysis of all EGMs to detect SCCs, and its accuracy is limited by electric far-field. We sought to evaluate an algorithm that automatically identifies EGM-DC, classifies mapping points, and creates new voltage maps, named "Slow Conducting Channel Maps" (SCC-Maps). Methods. Retrospective analysis of electroanatomic maps (EAM) from 20 patients (10 ischemic, 10 with arrhythmogenic right ventricular dysplasia/cardiomyopathy) was performed. EAM voltage maps were acquired during sinus rhythm and used for ablation. Preprocedural contrast-enhanced cardiac magnetic resonance (Ce-CMR) imaging was available for the ischemic population. Three mapping modalities were analysed: (i) EAM voltage maps using standard (EAM standard) or manual (EAM screening) thresholds for defining core and border zones; (ii) SCC-Maps derived from the use of the novel SCC-Mapping algorithm that automatically identify EGM-DCs measuring the voltage of the local component; and (iii) Ce-CMR maps (when available). The ability of each mapping modality in identifying SCCs and their agreement was evaluated. Results. SCC-Maps and EAM screening identified a greater number of SCC entrances than EAM standard (3.45 ± 1.61 and 2.95 ± 2.31, resp., vs. 1.05 ± 1.10; p<0.01). SCC-Maps and EAM screening highly correlate with Ce-CMR maps in the ischemic population when compared to EAM standard (Lin''s correlation = 0.628 and 0.679, resp., vs. 0.212, p<0.01). Conclusion. The SCC-Mapping algorithm allows an operator-independent analysis of EGM signals showing better identification of the arrhythmogenic substrate characteristics when compared to standard voltage EAM.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Otros (Other)

Editorial: Perspectives of Antiarrhythmic Drug Therapy: Disappointing Past, Current Efforts, and Faint Hopes

  • Nánási, P.P.
  • Pueyo, E.
  • Virág, L.
Present issue is devoted to those areas of cardiac electrophysiology, pathophysiology, and pharmacology which are critically important to improve the efficacy of antiarrhythmic treatment. Cardiac arrhythmia is a leading cause of morbidity and mortality, and the history of anti-arrhythmic drug therapies has been dismal...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Automatic quantification of cardiomyocyte dimensions and connexin 43 lateralization in fluorescence images

  • Oliver-Gelabert, A.
  • García-Mendívil, L.
  • Vallejo-Gil, J.M.
  • Fresneda-Roldán, P.C.
  • Andelová, K.
  • Fañanás-Mastral, J.
  • Vázquez-Sancho, M.
  • Matamala-Adell, M.
  • Sorribas-Berjón, F.
  • Ballester-Cuenca, C.
  • Tribulova, N.
  • Ordovás, L.
  • Diez, E.R.
  • Pueyo, E.
Cardiomyocytes’ geometry and connexin 43 (CX43) amount and distribution are structural features that play a pivotal role in electrical conduction. Their quantitative assessment is of high interest in the study of arrhythmias, but it is usually hampered by the lack of automatic tools. In this work, we propose a software algorithm (Myocyte Automatic Retrieval and Tissue Analyzer, MARTA) to automatically detect myocytes from fluorescent microscopy images of cardiac tissue, measure their morphological features and evaluate the expression of CX43 and its degree of lateralization. The proposed software is based on the generation of cell masks, contouring of individual cells, enclosing of cells in minimum area rectangles and splitting of these rectangles into end-to-end and middle compartments to estimate CX43 lateral-to-total ratio. Application to human ventricular tissue images shows that mean differences between automatic and manual methods in terms of cardiomyocyte length and width are below 4 µm. The percentage of lateral CX43 also agrees between automatic and manual evaluation, with the interquartile range approximately covering from 3% to 30% in both cases. MARTA is not limited by fiber orientation and has an optimized speed by using contour filtering, which makes it run hundreds of times faster than a trained expert. Developed for CX43 studies in the left ventricle, MARTA is a flexible tool applicable to morphometric and lateralization studies of other markers in any heart chamber or even skeletal muscle. This open-access software is available online.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Heart Rate Variability and Exceptional Longevity

  • Hernández-Vicente, A.
  • Hernando, D.
  • Santos-Lozano, A.
  • Rodríguez-Romo, G.
  • Vicente-Rodríguez, G.
  • Pueyo, E.
  • Bailón, R.
  • Garatachea, N.
Centenarians are the paradigm of human extreme longevity and healthy aging, because they have postponed, if not avoided, mayor age-related diseases. The purpose of this study was to investigate potential differences in resting heart rate variability (HRV) between young adults, octogenarians, and centenarians and assess whether HRV variables are predictors of all-cause mortality in centenarians. To this end, three groups of participants: young adults (N = 20; 20.6 ± 2.3 years), octogenarians (N = 18; 84.1 ± 2.6 years), and centenarians (N = 17; 101.9 ± 1.9 years) were monitored for 15 min at rest (seated, without moving or talking) to measure RR intervals, from which HRV was evaluated. Our results showed a clear decrease with age in the main parasympathetic HRV variables, as well as in the standard deviation (SD) of the RR series [SD of normal-to-normal interval (SDNN)] and in low frequency (LF) heart rate (HR) oscillations, although differences between octogenarians and centenarians did not reach statistical significance. In 14 centenarians followed until death, only SDNN showed significant correlation (¿ = 0.536; p = 0.048) with survival prognosis. Additionally, SDNN <19 ms was associated with early mortality (=1 year) in centenarians (Hazard Ratio = 5.72). In conclusion, HRV indices reflecting parasympathetic outflow as well as SDNN and LF all present an age-related reduction, which could be representative of a natural exhaustion of allostatic systems related to age. Moreover, low SDNN values (<19 ms) could be associated with early mortality in centenarians. HRV seems to play a role in exceptional longevity, which could be accounted for by centenarians’ exposome.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Minimally invasive system to reliably characterize ventricular electrophysiology from living donors

  • Oliván-Viguera, A.
  • Pérez-Zabalza, M.
  • García-Mendívil, L.
  • Mountris, K.A.
  • Orós-Rodrigo, S.
  • Ramos-Marquès, E.
  • Vallejo-Gil, J.M.
  • Fresneda-Roldán, P.C.
  • Fañanás-Mastral, J.
  • Vázquez-Sancho, M.
  • Matamala-Adell, M.
  • Sorribas-Berjón, F.
  • Bellido-Morales, J.A.
  • Mancebón-Sierra, F.J.
  • Vaca-Núñez, A.S.
  • Ballester-Cuenca, C.
  • Marigil, M.Á.
  • Pastor, C.
  • Ordovás, L.
  • Köhler, R.
  • Diez, E.
  • Pueyo, E.
Cardiac tissue slices preserve the heterogeneous structure and multicellularity of the myocardium and allow its functional characterization. However, access to human ventricular samples is scarce. We aim to demonstrate that slices from small transmural core biopsies collected from living donors during routine cardiac surgery preserve structural and functional properties of larger myocardial specimens, allowing accurate electrophysiological characterization. In pigs, we compared left ventricular transmural core biopsies with transmural tissue blocks from the same ventricular region. In humans, we analyzed transmural biopsies and papillary muscles from living donors. All tissues were vibratome-sliced. By histological analysis of the transmural biopsies, we showed that tissue architecture and cellular organization were preserved. Enzymatic and vital staining methods verified viability. Optically mapped transmembrane potentials confirmed that action potential duration and morphology were similar in pig biopsies and tissue blocks. Action potential morphology and duration in human biopsies and papillary muscles agreed with published ranges. In both pigs and humans, responses to increasing pacing frequencies and ß-adrenergic stimulation were similar in transmural biopsies and larger tissues. We show that it is possible to successfully collect and characterize tissue slices from human myocardial biopsies routinely extracted from living donors, whose behavior mimics that of larger myocardial preparations both structurally and electrophysiologically.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Commentary: Increased Beat-to-Beat Variability of T-Wave Heterogeneity Measured From Standard 12-Lead Electrocardiogram Is Associated With Sudden Cardiac Death: A Case-Control Study

  • Chauhan, V.S.
  • Martínez, J.P.
  • van der Heyden, M.A.G.
The electrocardiogram (ECG) reflects the electrical activity within the heart. Following the discovery of the small electrical signals in the human heart, the Dutch scientist Willem Einthoven developed sensitive methods for detecting them and recognized their clinical implications (Kligfield, 2002). For his contributions Willem Einthoven, whose scientific roots originated from the Utrecht physiology department (Einthoven, 1885), was awarded the Nobel Prize in 1924. Since then, many enigmas of the ECG have been solved and its intricate information carries valuable clues for clinical decision making. In vivo mapping studies have established that spatial heterogeneity in repolarization is a requisite for re-entrant ventricular arrhythmias by effecting unidirectional conduction block. Important modulators of spatial heterogeneity of repolarization include autonomic tone, ischemia, heart rate and premature or ectopic beats, which can produce temporal heterogeneity in the order of seconds, minutes, or hours depending on their time-constants. In the contemporary era of dynamic surface electrocardiography, a formidable challenge is quantifying spatiotemporal repolarization heterogeneity with sufficient fidelity to image the arrhythmogenic myocardial substrate and thereby provide indices for a patient’s risk of arrhythmic death (Laguna et al., 2016). Hekkanen et al. (2020) performed a large case-control study of 200 victims...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of t wave amplitude, duration and morphology changes during hemodialysis: Relationship with serum electrolyte levels and heart rate

  • Bukhari, Syed Hassaan Ahmed
  • Palmieri, Flavio
  • Ramírez, Julia
  • Laguna, Pablo
  • Ruiz, José Esteban
  • Ferreira, Dina
  • Potse, Mark
  • Sánchez, Carlos
  • Pueyo, Esther
Objective: Chronic kidney disease affects more than 10% of the world population. Changes in serum ion concentrations increase the risk for ventricular arrhythmias and sudden cardiac death, particularly in end stage renal disease (ESRD) patients. We characterized how T wave amplitude, duration and morphology descriptors change with variations in serum levels of potassium and calcium and in heart rate, both in ESRD patients and in simulated ventricular fibers. Methods: Electrocardiogram (ECG) recordings from twenty ESRD patients undergoing hemodialysis (HD) and pseudo-ECGs (pECGs) calculated from twenty-two simulated ventricular fibers at varying transmural heterogeneity levels were processed to quantify T wave width (Tw), T wave slope-to-amplitude ratio (TS/A) and four indices of T wave morphological variability based on time warping (dw, dNLw, da and dNLa). Serum potassium and calcium levels and heart rate were measured along HD. Results: dNL with serum potassium, dw with calcium and da with heart rate, after correction for covariates. Median values of partial correlation coefficients were 0.75,−0.74 and −0.90, respectively. For all analyzed T wave descriptors, high inter-patient variability was observed in the pattern of such relationships. This variability, accentuated during the first HD time points, was reproduced in the simulations and shown to be influenced by differences in transmural heterogeneity. Conclusion: Changes in serum potassium and calcium levels and in heart rate strongly affect T wave descriptors, particularly those quantifying morphological variability. Significance: ECG markers have the potential to be used for monitoring serum ion concentrations in ESRD patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Acute stress state classification based on electrodermal activity modeling

  • Greco, A.
  • Valenza, G.
  • Lázaro, J.
  • Garzón-Rey, J. M.
  • Aguiló, J.
  • De la Cámara, C.
  • Bailón, Raquel
  • Scilingo, Enzo Pascuale
Acute stress is a physiological condition that may induce several neural dysfunctions with a significant impact on life quality. Accordingly, it would be important to monitor stress in everyday life unobtrusively and inexpensively. In this paper, we presented a new methodological pipeline to recognize acute stress conditions using electrodermal activity (EDA) exclusively. Particularly, we combined a rigorous and robust model (cvxEDA) for EDA processing and decomposition, with an algorithm based on a support vector machine to classify the stress state at a single- subject level. Indeed, our method, based on a single sensor, is robust to noise, applies a rigorous phasic decomposition, and implements an unbiased multiclass classification. To this end, we analyzed the EDA of 65 volunteers subjected to different acute stress stimuli induced by a modified version of the Trier Social Stress Test. Our results show that stress is successfully detected with an average accuracy of 94.62%. Besides, we proposed a further 4-class pattern recognition system able to distinguish between non-stress condition and three different stressful stimuli achieving an average accuracy as high as 75.00%. These results, obtained under controlled conditions, are the first step towards applications in ecological scenarios.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Atrial Dyssynchrony Measured by Strain Echocardiography as a Marker of Proarrhythmic Remodeling and Oxidative Stress in Cardiac Surgery Patients

  • Sanchez, F.J.
  • Gonzalez, V.A.
  • Farrando, M.
  • Baigorria Jayat, A.O.
  • Segovia-Roldan, M.
  • Garciá-Mendívil, L.
  • Ordovás, L.
  • Prado, N.J.
  • Pueyo, E.
  • Diez, E.R.
Aging leads to structural and electrophysiological changes that increase the risk of postoperative atrial arrhythmias; however, noninvasive preoperative markers of atrial proarrhythmic conditions are still needed. This study is aimed at assessing whether interatrial dyssynchrony determined using two-dimensional speckle tracking echocardiography relates to proarrhythmic structural and functional remodeling. A cohort of 45 patients in sinus rhythm referred for cardiac surgery was evaluated by echocardiography and surface electrocardiogram the day before the intervention. Transmembrane potential, connexin, and potassium channel distribution, inflammatory, and nitrooxidative markers were measured from right atrial tissue obtained from patients. A difference greater than 40 milliseconds between right and left atrial free wall contraction confirmed the presence of interatrial dyssynchrony in 21 patients. No difference in relation with age, previous diseases, and 2-dimensional echocardiographic findings as well as average values of global longitudinal right and left atrial strain were found between synchronic and dyssynchronic patients. Postoperative atrial fibrillation incidence increased from 8.3% in the synchronic group to 33.3% in the dyssynchronic ones. P wave duration showed no difference between groups. Action potentials from dyssynchronous patients decreased in amplitude, maximal rate of depolarization, and hyperpolarized. Duration at 30% of repolarization increased, being markedly shorter at 90% of repolarization. Only the dyssynchronous group showed early and delayed afterdepolarizations. Atrial tissue of dyssynchronous patients displayed lateralization of connexin 40 and increased connexin 43 expression and accumulation of tumor necrosis factor-a in the intercalated disc. Tumor necrosis factor-a did not colocalize, however, with lateralized connexin 40. Nitroxidative marks and KATP channels increased perivascularly and in myocytes. Our results demonstrate that, as compared to a traditional surface electrocardiogram, the novel noninvasive echocardiographic evaluation of interatrial dyssynchrony provides a better identification of nonaged-related proarrhythmic atrial remodeling with increased susceptibility to postoperative atrial fibrillation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of Spatiooral Cardiac Action Potential Variability at Baseline and under ß-Adrenergic Stimulation by Combined Unscented Kalman Filter and Double Greedy Dimension Reduction

  • Sampedro-Puente, D.A.
  • Raphel, F.
  • Fernandez-Bes, J.
  • Laguna, P.
  • Lombardi, D.
  • Pueyo, E.
Objective: Elevated spatiooral variability of human ventricular repolarization has been related to increased risk for ventricular arrhythmias and sudden cardiac death, particularly under ß-adrenergic stimulation (ß-AS). This work presents a methodology for theoretical characterization of temporal and spatial repolarization variability at baseline conditions and in response to ß-AS. For any measured voltage trace, the proposed methodology estimates the parameters and state variables of an underlying human ventricular action potential (AP) model by combining Double Greedy Dimension Reduction (DGDR) with automatic selection of biomarkers and the Unscented Kalman Filter (UKF). Such theoretical characterization can facilitate subsequent characterization of underlying variability mechanisms. Material and Methods: Given an AP trace, initial estimates for the ionic conductances in a stochastic version of the baseline human ventricular O'Hara et al. model were obtained by DGDR. Those estimates served to initialize and update model parameter estimates by the UKF method based on formulation of an associated nonlinear state-space representation and joint estimation of model parameters and state variables. Similarly, ß-AS-induced phosphorylation levels of cellular substrates were estimated by the DGDR-UKF methodology. Performance was tested by building an experimentally-calibrated population of virtual cells, from which synthetic AP traces were generated for baseline and ß-AS conditions. Results: The combined DGDR-UKF methodology led to 25% reduction in the error associated with estimation of ionic current conductances at baseline conditions and phosphorylation levels under ß-AS with respect to individual DGDR and UKF methods. This improvement was not at the expense of higher computational load, which was diminished by 90% with respect to the individual UKF method. Both temporal and spatial AP variability of repolarization were accurately characterized by the DGDR-UKF methodology. Conclusions: A combined DGDR-UKF methodology is proposed for parameter and state variable estimation of human ventricular cell models from available AP traces at baseline and under ß-AS. This methodology improves the estimation performance and reduces the convergence time with respect to individual DGDR and UKF methods and renders a suitable approach for computational characterization of spatiooral repolarization variability to be used for ascertainment of variability mechanisms and its relation to arrhythmogenesis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Omnipolar EGM voltage mapping for atrial fibrosis identification evaluated with an electrophysiological model

  • Riccio, J.
  • Alcaine, A.
  • Rocher, S.
  • Laguna, P.
  • Saiz, J.
  • Martínez, J.P.
Atrial fibrillation (AF) is the most spread heart arrhythmia, whose mechanisms are not completely clear yet. Catheter ablation is a standard treatment, which isolates the area involved in the arrhythmia. Intracardiac electrograms (EGMs) are used to better understand the AF mechanisms and to find appropriate ablation sites. Bipolar EGMs (b-EGMs) are often employed, but their amplitude and shape depend on catheter orientation, limiting reliability. To avoid this uncertainty, an approach insensitive to catheter orientation, referred as Omnipolar EGM (OP-EGM) method, has been introduced, which uses an estimation of the electric field within a group of electrodes, referred as clique. In this work, we compare different mapping approaches based on b-EGMs and OP-EGM signals in simulation including fibrosis, so to evaluate their ability to detect fibrosis and reproduce the spatial distribution of the voltage. Maps have been computed using two clique configurations (square and triangular), introducing or not a previous time alignment of the b-EGMs. OP-EGM signals have been obtained by projecting the electric field along directions of its maximal excursion and its principal components. Results show that the proposed alignment of b-EGMs improves maps based on OP-EGM signals. Both cliques configurations present good performance, in terms of fibrosis detection and correlation with the reference voltage maps.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Unipolar Electrogram Eigenvalue Distribution Analysis for the Identification of Atrial Fibrosis

  • Riccio, Jennifer
  • Rocher Ventura, Sara
  • Martínez Mateu, Laura
  • Alcaine Otín, Alejandro
  • Sáiz Rodríguez, Javier
  • Martínez Cortés, Juan Pablo
  • Laguna Lasaosa, Pablo
Atrial fibrosis plays an important role in the pathogenesis of atrial fibrillation (AF). Low bipolar electrograms (b-EGMs) peak-to-peak voltage areas indicate scar tissue and are considered targets for AF substrate ablation. However, this approach ignores the spatiotemporal information embedded in the signal and the dependence of b-EGMs on catheter orientation. This work proposes an approach to detect fibrosis based on the eigenvalue dominance ratio (EIGDR) in an ensemble (clique) of unipolar electrograms (u-EGMs). A 2-D tissue with a central circular patch of fibrosis has been simulated using the Courtemanche cellular model. Maps of EIGDR have been computed using two sizes of electrode cliques, from the original u-EGMs within the ensemble or after a time alignment of these signals. Performance of each map in detecting fibrosis has been evaluated using receiver operating characteristic curves and detection accuracy. Best results achieve an area under the curve (AUC) of 0.98 and an accuracy (ACC) of 1 when we use as marker the gain in eigenvalue dominance produced by the ensemble alignment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Relationship between Atrial Oscillatory Acetylcholine Release Pattern and f-wave Frequency Modulation: a Computational and Experimental Study

  • Celotto, Chiara
  • Sánchez Tapia, Carlos
  • Mountris, Konstantinos
  • Abdollahpur, Mostafa
  • Sandberg, Frida
  • Laguna Lasaosa, Pablo
  • Pueyo Paúles, Esther
The frequency of fibrillatory waves (f-waves), F f , exhibits significant variation over time, and previous studies suggest that some of this variation is related to respiratory modulation through the autonomic nervous system. In this study, we tested the hypothesis that this variation (ΔF f ) could be related to acetylcholine concentration ([ACh]) release pattern. Electrocardiograms were recorded from seven patients during controlled respiration before and after full vagal blockade, from which f-wave frequency modulation was characterized. Computational simulations in human atrial tissues were performed to assess the effects of [ACh] release pattern on F f and compared to experimental results in humans. A cross-stimulation protocol was applied onto the tissue to initiate a rotor while cyclically varying [ACh] following a sinusoidal waveform of frequency equal to 0.125 Hz. Different mean levels (0.05, 0.075μM/l) and peak-to-peak ranges (0.1, 0.05, 0.025 μM/l) of [ACh] variation were tested. In all patients, an f-wave frequency modulation could be observed. In 57% of the patients, this modulation was significantly reduced after vagal blockade. Simulations confirmed that rotor frequency variations followed the induced [ACh] patterns. Mean F f was dependent on mean [ACh] level, whileΔF f was dependent on [ACh] variation range.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Monitoring blood potassium concentration in hemodialysis patients by quantifying T-wave morphology dynamics

  • Palmieri, F.
  • Gomis, P.
  • Ferreira, D.
  • Ruiz, J.E.
  • Bergasa, B.
  • Martín-Yebra, A.
  • Bukhari, H.A.
  • Pueyo, E.
  • Martínez, J.P.
  • Ramírez, J.
  • Laguna, P.
We investigated the ability of time-warping-based ECG-derived markers of T-wave morphology changes in time (dw) and amplitude (da), as well as their non-linear components (dNLw and dNLa), and the heart rate corrected counterpart (dw,c), to monitor potassium concentration ([K+]) changes (Δ[K+]) in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD). We compared the performance of the proposed time-warping markers, together with other previously proposed [K+] markers, such as T-wave width (Tw) and T-wave slope-to-amplitude ratio (TS/A), when computed from standard ECG leads as well as from principal component analysis (PCA)-based leads. 48-hour ECG recordings and a set of hourly-collected blood samples from 29 ESRD-HD patients were acquired. Values of dw, da, dNLw, dNLa and dw,c were calculated by comparing the morphology of the mean warped T-waves (MWTWs) derived at each hour along the HD with that from a reference MWTW, measured at the end of the HD. From the same MWTWs Tw and TS/A were also extracted. Similarly, Δ[K+] was calculated as the difference between the [K+] values at each hour and the [K+] reference level at the end of the HD session. We found that dw and dw,c showed higher correlation coefficients with Δ[K+] than TS/A—Spearman’s (ρ) and Pearson’s (r)—and Tw—Spearman’s (ρ)—in both SL and PCA approaches being the intra-patient median ρ≥0.82 and r≥0.87 in SL and ρ≥0.82 and r≥0.89 in PCA respectively. Our findings would point at dw and dw,c as the most suitable surrogate of Δ[K+], suggesting that they could be potentially useful for non-invasive monitoring of ESRD-HD patients in hospital, as well as in ambulatory settings. Therefore, the tracking of T-wave morphology variations by means of time-warping analysis could improve continuous and remote [K+] monitoring of ESRD-HD patients and flagging risk of [K+]-related cardiovascular events.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Validity of the polar h7 heart rate sensor for heart rate variability analysis during exercise in different age, body composition and fitness level groups

  • Hernández-Vicente, A.
  • Hernando, D.
  • Marín-Puyalto, J.
  • Vicente-Rodríguez, G.
  • Garatachea, N.
  • Pueyo, E.
  • Bailón, R.
This work aims to validate the Polar H7 heart rate (HR) sensor for heart rate variability (HRV) analysis at rest and during various exercise intensities in a cohort of male volunteers with different age, body composition and fitness level. Cluster analysis was carried out to evaluate how these phenotypic characteristics influenced HR and HRV measurements. For this purpose, sixty-seven volunteers performed a test consisting of the following consecutive segments: sitting rest, three submaximal exercise intensities in cycle-ergometer and sitting recovery. The agreement between HRV indices derived from Polar H7 and a simultaneous electrocardiogram (ECG) was assessed using concordance correlation coefficient (CCC). The percentage of subjects not reaching excellent agreement (CCC > 0.90) was higher for high-frequency power (PHF) than for low-frequency power (PLF) of HRV and increased with exercise intensity. A cluster of unfit and not young volunteers with high trunk fat percentage showed the highest error in HRV indices. This study indicates that Polar H7 and ECG were interchangeable at rest. During exercise, HR and PLF showed excellent agreement between devices. However, during the highest exercise intensity, CCC for PHF was lower than 0.90 in as many as 60% of the volunteers. During recovery, HR but not HRV measurements were accurate. As a conclusion, phenotypic differences between subjects can represent one of the causes for disagreement between HR sensors and ECG devices, which should be considered specifically when using Polar H7 and, generally, in the validation of any HR sensor for HRV analysis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Feasibility of atrial fibrillation detection from a novel wearable armband device

  • Bashar, Syed Khairul
  • Hossain, Md-Billal
  • Lázaro Plaza, Jesús
  • Ding, Eric Y.
  • Noh, Yeonsik
  • Cho, Chae Ho
  • McManus, David D.
  • Fitzgibbons, Timothy P.
  • Chon, Ki H.
Background Atrial fibrillation (AF) is the world’s most common heart rhythm disorder and even several minutes of AF episodes can contribute to risk for complications, including stroke. However, AF often goes undiagnosed owing to the fact that it can be paroxysmal, brief, and asymptomatic. Objective To facilitate better AF monitoring, we studied the feasibility of AF detection using a continuous electrocardiogram (ECG) signal recorded from a novel wearable armband device. Methods In our 2-step algorithm, we first calculate the R-R interval variability–based features to capture randomness that can indicate a segment of data possibly containing AF, and subsequently discriminate normal sinus rhythm from the possible AF episodes. Next, we use density Poincaré plot-derived image domain features along with a support vector machine to separate premature atrial/ventricular contraction episodes from any AF episodes. We trained and validated our model using the ECG data obtained from a subset of the MIMIC-III (Medical Information Mart for Intensive Care III) database containing 30 subjects. Results When we tested our model using the novel wearable armband ECG dataset containing 12 subjects, the proposed method achieved sensitivity, specificity, accuracy, and F1 score of 99.89%, 99.99%, 99.98%, and 0.9989, respectively. Moreover, when compared with several existing methods with the armband data, our proposed method outperformed the others, which shows its efficacy. Conclusion Our study suggests that the novel wearable armband device and our algorithm can be used as a potential tool for continuous AF monitoring with high accuracy.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cardiopulmonary coupling indices to assess weaning readiness from mechanical ventilation

  • Armañac-Julian, Pablo
  • Hernando, David
  • Lázaro, Jesús
  • Haro, Candelaria de
  • Magrans, Rudys
  • Morales, John
  • Moeyersons, Jonathan
  • Sarlabous, Leonardo
  • López-Aguilar, Josefina
  • Subirà, Carles
  • Fernández, Rafael
  • Orini, Michele
  • Laguna, Pablo
  • Varon, Carolina
  • Gil, Eduardo
  • Bailón, Raquel
  • Blanch, Lluís
The ideal moment to withdraw respiratory supply of patients under Mechanical Ventilation at Intensive Care Units (ICU), is not easy to be determined for clinicians. Although the Spontaneous Breathing Trial (SBT) provides a measure of the patients’ readiness, there is still around 15–20% of predictive failure rate. This work is a proof of concept focused on adding new value to the prediction of the weaning outcome. Heart Rate Variability (HRV) and Cardiopulmonary Coupling (CPC) methods are evaluated as new complementary estimates to assess weaning readiness. The CPC is related to how the mechanisms regulating respiration and cardiac pumping are working simultaneously, and it is defined from HRV in combination with respiratory information. Three different techniques are used to estimate the CPC, including Time-Frequency Coherence, Dynamic Mutual Information and Orthogonal Subspace Projections. The cohort study includes 22 patients in pressure support ventilation, ready to undergo the SBT, analysed in the 24 h previous to the SBT. Of these, 13 had a successful weaning and 9 failed the SBT or needed reintubation –being both considered as failed weaning. Results illustrate that traditional variables such as heart rate, respiratory frequency, and the parameters derived from HRV do not differ in patients with successful or failed weaning. Results revealed that HRV parameters can vary considerably depending on the time at which they are measured. This fact could be attributed to circadian rhythms, having a strong influence on HRV values. On the contrary, significant statistical differences are found in the proposed CPC parameters when comparing the values of the two groups, and throughout the whole recordings. In addition, differences are greater at night, probably because patients with failed weaning might be experiencing more respiratory episodes, e.g. apneas during the night, which is directly related to a reduced respiratory sinus arrhythmia. Therefore, results suggest that the traditional measures could be used in combination with the proposed CPC biomarkers to improve weaning readiness.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Estimation of the second ventilatory threshold through ventricular repolarization profile analysis

  • Milagro, J.
  • Hernández-Vicente, A.
  • Hernando, D.
  • Casajús, J.A.
  • Garatachea, N.
  • Bailón, R.
  • Pueyo, E.
Under the hypothesis that sympathetic control of ventricular repolarization may change once the second ventilatory threshold (VT2) has been reached, a novel methodology for non-invasive VT2 estimation based on the analysis of the T wave from the electrocardiogram (ECG) is proposed, and potential underlying physiological mechanisms are suggested. 25 volunteers (33.4 ± 5.2 years) underwent an incremental power cycle ergometer test (25 W/minute). During the test, respiratory gas exchange and multi-lead ECG were acquired. The former was employed to determine VT2, used here as a reference, whereas the latter was used to compute the temporal profiles of an index of ventricular repolarization instability (dT) and its low-frequency (LF) oscillations (LFdT). The sudden increases observed in dT and LFdT profiles above an established heart rate threshold were employed to derive VT2 estimates, referred to as VT2dT and VT2LFdT, respectively. Estimation errors of -4.7 ± 25.2 W were obtained when considering VT2dT. Errors were lower than the one-minute power increment of 25 W in 68% of the subjects and lower than 50 W in 89.5% of them. When using VT2LFdT, estimation error was of 15.3 ± 32.4 W. Most of the subjects shared common characteristic dT and LFdT profiles, which could be reflecting changes in the autonomic control of ventricular repolarization before and after reaching VT2. The analysis of ventricular repolarization dynamics during exercise allows non-invasive ECG-based estimation of VT2, possibly in relation to changes in the autonomic control of ventricular electrical activity when VT2 is reached.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Proposal for a home sleep monitoring platform employing a smart glove

  • Lazazzera, Remo
  • Laguna, Pablo
  • Gil, Eduardo
  • Carrault, Guy
The present paper proposes the design of a sleep monitoring platform. It consists of an entire sleep monitoring system based on a smart glove sensor called UpNEA worn during the night for signals acquisition, a mobile application, and a remote server called AeneA for cloud computing. UpNEA acquires a 3-axis accelerometer signal, a photoplethysmography (PPG), and a peripheral oxygen saturation (SpO2) signal from the index finger. Overnight recordings are sent from the hardware to a mobile application and then transferred to AeneA. After cloud computing, the results are shown in a web application, accessible for the user and the clinician. The AeneA sleep monitoring activity performs different tasks: sleep stages classification and oxygen desaturation assessment; heart rate and respiration rate estimation; tachycardia, bradycardia, atrial fibrillation, and premature ventricular contraction detection; and apnea and hypopnea identification and classification. The PPG breathing rate estimation algorithm showed an absolute median error of 0.5 breaths per minute for the 32 s window and 0.2 for the 64 s window. The apnea and hypopnea detection algorithm showed an accuracy (Acc) of 75.1%, by windowing the PPG in one-minute segments. The classification task revealed 92.6% Acc in separating central from obstructive apnea, 83.7% in separating central apnea from central hypopnea and 82.7% in separating obstructive apnea from obstructive hypopnea. The novelty of the integrated algorithms and the top-notch cloud computing products deployed, encourage the production of the proposed solution for home sleep monitoring.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of Atrial Propagation Patterns and Fibrotic Substrate With a Modified Omnipolar Electrogram Strategy in Multi-Electrode Arrays

  • Riccio, J
  • Alcaine, A
  • Rocher, S
  • Martinez-Mateu, L
  • Laranjo, S
  • Saiz, J
  • Laguna, P
  • Martinez, JP
Introduction: The omnipolar electrogram method was recently proposed to try to generate orientation-independent electrograms. It estimates the electric field from the bipolar electrograms of a clique, under the assumption of locally plane and homogeneous propagation. The local electric field evolution over time describes a loop trajectory from which omnipolar signals in the propagation direction, substrate and propagation features, are derived. In this work, we propose substrate and conduction velocity mapping modalities based on a modified version of the omnipolar electrogram method, which aims to reduce orientation-dependent residual components in the standard approach.</p> & nbsp;</p> Methods: A simulated electrical propagation in 2D, with a tissue including a circular patch of diffuse fibrosis, was used for validation. Unipolar electrograms were calculated in a multi-electrode array, also deriving bipolar electrograms along the two main directions of the grid. Simulated bipolar electrograms were also contaminated with real noise, to assess the robustness of the mapping strategies against noise. The performance of the maps in identifying fibrosis and in reproducing unipolar reference voltage maps was evaluated. Bipolar voltage maps were also considered for performance comparison.</p> & nbsp;</p> Results: Results show that the modified omnipolar mapping strategies are more accurate and robust against noise than bipolar and standard omnipolar maps in fibrosis detection (accuracies higher than 85 vs. 80% and 70%, respectively). They present better correlation with unipolar reference voltage maps than bipolar and original omnipolar maps (Pearson''s correlations higher than 0.75 vs. 0.60 and 0.70, respectively).</p> & nbsp;</p> Conclusion: The modified omnipolar method improves fibrosis detection, characterization of substrate and propagation, also reducing the residual sensitivity to directionality over the standard approach and improving robustness against noise. Nevertheless, studies with real electrograms will elucidate its impact in catheter ablation interventions.</p>
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Periodic repolarization dynamics as predictor of risk for sudden cardiac death in chronic heart failure patients

  • Palacios, Saúl
  • Cygankiewicz, Iwona
  • Bayés de Luna, Antoni
  • Pueyo, Esther
  • Martínez, Juan Pablo
The two most common modes of death among chronic heart failure (CHF) patients are sudden cardiac death (SCD) and pump failure death (PFD). Periodic repolarization dynamics (PRD) quantifies low-frequency oscillations in the T wave vector of the electrocardiogram (ECG) and has been postulated to reflect sympathetic modulation of ventricular repolarization. This study aims to evaluate the prognostic value of PRD to predict SCD and PFD in a population of CHF patients. 20-min high-resolution (1000 Hz) ECG recordings from 569 CHF patients were analyzed. Patients were divided into two groups, PRD+ and PRD-, corresponding to PRD values above and below the optimum cutoff point of PRD in the study population. Univariate Cox regression analysis showed that SCD risk in the PRD+ group was double the risk in the PRD- group [ hazard ratio (95% CI) 2.001 (1.127-3.554), p < 0.05]. The combination of PRD with other Holter-based ECG indices, such as turbulence slope (TS) and index of average alternans (IAA), improved SCD prediction by identifying groups of patients at high SCD risk. PFD could be predicted by PRD only when combined with TS [hazard ratio 2.758 (1.572-4.838), p < 0.001]. In conclusion, the combination of PRD with IAA and TS can be used to stratify the risk for SCD and PFD, respectively, in CHF patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

QT variability unrelated to RR variability during stress testing for identification of coronary artery disease

  • González del Castillo, Marta
  • Hernando, David
  • Orini, Michele
  • Laguna, Pablo
  • Viik, Jari
  • Bailón, Raquel
  • Pueyo, Esther
Stress test electrocardiogram (ECG) analysis is widely used for coronary artery disease (CAD) diagnosis despite its limited accuracy. Alterations in autonomic modulation of cardiac electrical activity have been reported in CAD patients during acute ischemia. We hypothesized that those alterations could be reflected in changes in ventricular repolarization dynamics during stress testing that could be measured through QT interval variability (QTV). However, QTV is largely dependent on RR interval variability (RRV), which might hinder intrinsic ventricular repolarization dynamics. In this study, we investigated whether different markers accounting for low-frequency (LF) oscillations of QTV unrelated to RRV during stress testing could be used to separate patients with and without CAD. Power spectral density of QTV unrelated to RRV was obtained based on time-frequency coherence estimation. Instantaneous LF power of QTV and QTV unrelated to RRV were obtained. LF power of QTV unrelated to RRV normalized by LF power of QTV was also studied. Stress test ECG of 100 patients were analysed. Patients referred to coronary angiography were classified into non-CAD or CAD group. LF oscillations in QTV did not show significant differences between CAD and non-CAD groups. However, LF oscillations in QTV unrelated to RRV were significantly higher in the CAD group as compared with the non-CAD group when measured during the first phases of exercise and last phases of recovery. ROC analysis of these indices revealed area under the curve values ranging from 61 to 73%. Binomial logistic regression analysis revealed LF power of QTV unrelated to RRV, both during the first phase of exercise and last phase of recovery, as independent predictors of CAD. In conclusion, this study highlights the importance of removing the influence of RRV when measuring QTV during stress testing for CAD identification and supports the added value of LF oscillations of QTV unrelated to RRV to diagnose CAD from the first minutes of exercise. This article is part of the theme issue 'Advanced computation in cardiovascular physiology: new challenges and opportunities'.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG-based monitoring of blood potassium concentration: Periodic versus principal component as lead transformation for biomarker robustness

  • Palmieri, Flavio
  • Gomis, Pedro
  • Ruiz, José Esteban
  • Ferreira, Dina
  • Martín-Yebra, Alba
  • Pueyo, Esther
  • Martínez, Juan Pablo
  • Ramírez, Julia
  • Laguna, Pablo
Objective: The aim of this study is to compare the performance of two electrocardiogram (ECG) lead-space reduction (LSR) techniques in generating a transformed ECG lead from which T-wave morphology markers can be reliably derived to non-invasively monitor blood potassium concentration ([K+]) in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD). These LSR techniques are: (1) principal component analysis (PCA), learned on the T wave, and (2) periodic component analysis (πCA), either learned on the whole QRST complex (πCB) or on the T wave (πCT). We hypothesized πCA is less sensitive to non-periodic disturbances, like noise and body position changes (BPC), than PCA, thus leading to more reliable T wave morphology markers. Methods: We compared the ability of T wave morphology markers obtained from PCA, πCB and πCT in tracking [K+] in an ESRD-HD dataset, including 29 patients, during and after HD (evaluated by correlation and residual fitting error analysis). We also studied their robustness to BPC using an annotated database, including 20 healthy individuals, as well as to different levels of noise using a simulation set-up (assessed by means of Mann–Whitney U test and relative error, respectively). Results: The performance of both πCB and πCT-based markers in following [K+]-variations during HD was comparable, and superior to that from PCA-based markers. Moreover, πCT-based markers showed superior robustness against BPC and noise. Conclusion: Both πCB and πCT outperform PCA in terms of monitoring [K+] in ESRD-HD patients, as well as of robustness against BPC and low SNR, with πCT showing the highest stability for continuous post-HD monitoring. Significance: The usage of πCA (i) increases the accuracy in monitoring dynamic [K+] variations in ESRD-HD patients and (ii) reduces the sensitivity to BPC and noise in deriving T wave morphology markers. © 2021 The Author(s)
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Reseña (Review)

Emerging evidence for a mechanistic link between low-frequency oscillation of ventricular repolarization measured from the electrocardiogram T-wave vector and arrhythmia

  • Taggart, P.
  • Pueyo, E.
  • Van Duijvenboden, S.
  • Porter, B.
  • Bishop, M.
  • Sampedro-Puente, D. A.
  • Orini, M.
  • Hanson, B.
  • Rinaldi, C. A.
  • Gill, J. S.
  • Lambiase, P.
Strong recent clinical evidence links the presence of prominent oscillations of ventricular repolarization in the low-frequency range (0.04-0.15 Hz) to the incidence of ventricular arrhythmia and sudden death in post-MI patients and patients with ischaemic and non-ischaemic cardiomyopathy. It has been proposed that these oscillations reflect oscillations of ventricular action potential duration at the sympathetic nerve frequency. Here we review emerging evidence to support that contention and provide insight into possible underlying mechanisms for this association.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Monitoring of serum potassium and calcium levels in end-stage renal disease patients by ecg depolarization morphology analysis

  • Bukhari, Syed Hassaan Ahmed
  • Sánchez, Carlos
  • Ruiz, José Esteban
  • Potse, Mark
  • Laguna, Pablo
  • Pueyo, Esther
Objective: Non-invasive estimation of serum potassium, [K+], and calcium, [Ca2+], can help to prevent life-threatening ventricular arrhythmias in patients with advanced renal disease, but current methods for estimation of electrolyte levels have limitations. We aimed to develop new markers based on the morphology of the QRS complex of the electrocardiogram (ECG). Methods: ECG recordings from 29 patients undergoing hemodialysis (HD) were processed. Mean warped QRS complexes were computed in two-minute windows at the start of an HD session, at the end of each HD hour and 48 h after it. We quantified QRS width, amplitude and the proposed QRS morphology-based markers that were computed by warping techniques. Reference [K+] and [Ca2+] were determined from blood samples acquired at the time points where the markers were estimated. Linear regression models were used to estimate electrolyte levels from the QRS markers individually and in combination with T wave morphology markers. Leave-one-out cross-validation was used to assess the performance of the estimators. Results: All markers, except for QRS width, strongly correlated with [K+] (median Pearson correlation coefficients, r, ranging from 0.81 to 0.87) and with [Ca2+] (r ranging from 0.61 to 0.76). QRS morphology markers showed very low sensitivity to heart rate (HR). Actual and estimated serum electrolyte levels differed, on average, by less than 0.035 mM (relative error of 0.018) for [K+] and 0.010 mM (relative error of 0.004) for [Ca2+] when patient-specific multivariable estimators combining QRS and T wave markers were used. Conclusion: QRS morphological markers allow non-invasive estimation of [K+] and [Ca2+] with low sensitivity to HR. The estimation performance is improved when multivariable models, including T wave markers, are considered. Significance: Markers based on the QRS complex of the ECG could contribute to non-invasive monitoring of serum electrolyte levels and arrhythmia risk prediction in patients with renal disease
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Strain Echocardiography to Predict Postoperative Atrial Fibrillation

  • Sanchez, Francisco Javier
  • Pueyo, Esther
  • Diez, Emiliano Raúl
Postoperative atrial fibrillation (POAF) complicates 15% to 40% of cardiovascular surgeries. Its incidence progressively increases with aging, reaching 50% in octogenarians. This arrhythmia is usually transient but it increases the risk of embolic stroke, prolonged hospital stay, and cardiovascular mortality. Though many pathophysiological mechanisms are known, POAF prediction is still a hot topic of discussion. Doppler echocardiogram and, lately, strain echocardiography have shown significant capacity to predict POAF. Alterations in oxidative stress, calcium handling, mitochondrial dysfunction, inflammation, fibrosis, and tissue aging are among the mechanisms that predispose patients to the perfect "atrial storm". Manifestations of these mechanisms have been related to enlarged atria and impaired function, which can be detected prior to surgery. Specific alterations in the atrial reservoir and pump function, as well as atrial dyssynchrony determined by echocardiographic atrial strain, can predict POAF and help to shed light on which patients could benefit from preventive therapy.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Editorial: Atrial Fibrillation: Technology for Diagnosis, Monitoring, and Treatment

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Analysis of age-related left ventricular collagen remodeling in living donors: Implications in arrhythmogenesis

  • García-Mendívil, Laura
  • Pérez-Zabalza, María
  • Mountris, Konstantinos
  • Duwé, Sam
  • Smisdom, Nick
  • Pérez, Marta
  • Luján, Lluis
  • Wolfs, Esther
  • Driesen, Ronald B.
  • Vallejo-Gil, José María
  • Fresneda-Roldán, Pedro Carlos
  • Fañanás-Mastral, Javier
  • Vázquez-Sancho, Manuel
  • Matamala-Adell, Marta
  • Sorribas-Berjón, Juan Fernando
  • Bellido-Morales, Javier André
  • Mancebón-Sierra, Francisco Javier
  • Vaca-Núñez, Alexander Sebastián
  • Ballester-Cuenca, Carlos
  • Oliván-Viguera, Aida
  • Diez, Emiliano
  • Ordovás, Laura
  • Pueyo, Esther
Age-related fibrosis in the left ventricle (LV) has been mainly studied in animals by assessing collagen content. Using second-harmonic generation microscopy and image processing, we evaluated amount, aggregation and spatial distribution of LV collagen in young to old pigs, and middle-age and elder living donors. All collagen features increased when comparing adult and old pigs with young ones, but not when comparing adult with old pigs or middle-age with elder individuals. Remarkably, all collagen parameters strongly correlated with lipofuscin, a biological age marker, in humans. By building patient-specific models of human ventricular tissue electrophysiology, we confirmed that amount and organization of fibrosis modulated arrhythmia vulnerability, and that distribution should be accounted for arrhythmia risk assessment. In conclusion, we characterize the age-associated changes in LV collagen and its potential implications for ventricular arrhythmia development. Consistency between pig and human results substantiate the pig as a relevant model of age-related LV collagen dynamics. © 2022 The Author(s)
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modelización matemática y simulación computacional de la variabilidad espacio-temporal en la actividad eléctrica cardíaca

  • Pueyo Paules, Esther
The electrical activity of the heart is the result of complex biophysical and biochemical processes occurring at different scales ranging from submicroscopic to macroscopic. The variability arising from these processes has important effects on cardiac function under both physiological and pathological conditions. In this review, mathematical modeling and simulation of cardiac electrical variability at the level of the cell, tissue and whole organ will be reviewed. A set of studies will be presented, which investigate the role that the stochastic gating of ion channels of cardiac cell membranes plays in the generation of electrical voltage variations along time. Also, methodologies for the development, calibration and evaluation of populations of mathematical models able to represent variations in cardiac electrophysiology across space, i.e. among cells, tissues or individuals, will be described. In particular, methods based on state-space representations, dimension reduction techniques and nonlinear adaptive filtering will be presented and their capacity to replicate experimentally measured spatio-temporal variability will be illustrated. The importance of these methodologies will be shown as a means to ascertain the mechanisms underlying variability, to establish the link between variability and cardiac arrhythmias (irregularities in heart beating) and to propose clinical markers for diagnosis, monitoring and treatment of cardiac diseases.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

QT interval Adaptation to Heart Rate Changes in Atrial Fibrillation as a Predictor of Sudden Cardiac Death

  • Martin-Yebra, A.
  • Sornmo, L.
  • Laguna, P.
Objective: The clinical significance of QT interval adaptation to heart rate changes has been poorly investigated in atrial fibrillation (AF), since QT delineation in the presence of f-waves is challenging. Therefore, the objective of the present study is to investigate new techniques for QT adaptation estimation in permanent AF. Methods: A multilead strategy based on generalized periodic component analysis is proposed for QT delineation, involving a spatial, linear transformation which emphasizes Twave periodicity and attenuates f-waves. QT adaptation is modeled by a linear, time-invariant filter, whose impulse response describes the dependence between the current QT interval and the preceding RR intervals, followed by a memoryless, possibly nonlinear, function. The QT adaptation time lag is determined from the estimated impulse response. Results: Using simulated ECGs in permanent AF, the transformed lead was found to offer more accurate QT delineation and time lag estimation than did the original ECG leads for a wide range of f-wave amplitudes (the time lag estimation error was found to be -0.2+/-0.6 s for SNR = 12 dB). In a population with chronic heart failure and permanent AF, the time lag estimated from the transformed lead was found to have the strongest, statistically significant association with sudden cardiac death (SCD) (hazard ratio = 3.49), whereas none of the original, orthogonal leads had any such association. Conclusions: Periodic component analysis provides more accurate QT delineation and improves time lag estimation in AF. A prolonged adaptation time of the QT interval to heart rate changes is associated with a high risk for SCD. Significance: This study demonstrates that SCD risk markers, originally developed for sinus rhythm, can also be used in AF, provided that Twave periodicity is emphasized. The time lag is a potentially useful marker for identifying patients at high risk for SCD, guiding clinicians in adopting effective therapeutic decisions. IEEE
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Dynamical mechanism for generation of arrhythmogenic early afterdepolarizations in cardiac myocytes: insights from in silico electrophysiological models

  • Barrio, R.
  • Martínez, M. A.
  • Serrano, S.
  • Pueyo, E.
We analyze the dynamical mechanisms underlying the formation of arrhythmogenic early afterdepolarizations (EADs) in two mathematical models of cardiac cellular electrophysiology: the Sato et al. biophysically detailed model of a rabbit ventricular myocyte of dimension 27 and a reduced version of the Luo-Rudy mammalian myocyte model of dimension 3. Based on a comparison of the two models, with detailed bifurcation analysis using spike-counting techniques and continuation methods in the simple model and numerical explorations in the complex model, we locate the point where the first EAD originates in an unstable branch of periodic orbits. These results serve as a basis to propose a conjectured scheme involving a hysteresis mechanism with the creation of alternans and EADs in the unstable branch. This theoretical scheme fits well with electrophysiological experimental data on EAD generation and hysteresis phenomena. Our findings open the door to the development of novel methods for pro-arrhythmia risk prediction related to EAD generation without actual induction of EADs.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cardiac cells stimulated with an axial current-like waveform reproduce electrophysiological properties of tissue fibers

  • Monasterio, Violeta
  • Pueyo, Esther
  • Rodríguez-Matas, José Félix
  • Carro, Jesús
Background and objective: In silico electrophysiological models are generally validated by comparing simulated results with experimental data. When dealing with single-cell and tissue scales simultaneously, as occurs frequently during model development and calibration, the effects of inter-cellular coupling should be considered to ensure the trustworthiness of model predictions. The hypothesis of this paper is that the cell-tissue mismatch can be reduced by incorporating the effects of conduction into the single-cell stimulation current. Methods: Five different stimulation waveforms were applied to the human ventricular O'Hara-Rudy cell model. The waveforms included the commonly used monophasic and biphasic (symmetric and asymmetric) pulses, a triangular waveform and a newly proposed asymmetric waveform (stimulation A) that resembles the transmembrane current associated with AP conduction in tissue. A comparison between single-cell and fiber simulated results was established by computing the relative difference between the values of AP-derived properties at different scales, and by evaluating the differences in the contributions of ionic conductances to each evaluated property. As a proof of the benefit, we investigated multi-scale differences in the simulation of the effects induced by dofetilide, a selective IKr blocker with high torsadogenic risk, on ventricular repolarization at different pacing rates. Results: Out of the five tested stimulation waveforms, stimulation A produced the closest correspondence between cell and tissue simulations in terms of AP properties at steady-state and under dynamic pacing and of ionic contributors to those AP properties. Also, stimulation A reproduced the effects of dofetilide better than the other alternative waveforms, mirroring the ’beat-skipping’ behavior observed at fast pacing rates in experiments with human tissue. Conclusions: The proposed stimulation current waveform accounts for inter-cellular coupling effects by mimicking cell excitation during AP conduction. The proposed waveform improves the correspondence between simulation scales, which could improve the trustworthiness of single-cell simulations without adding computational cost. © 2022
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effects of missing data on heart rate variability metrics

  • Cajal, Diego
  • Hernando, David
  • Lázaro, Jesús
  • Laguna, Pablo
  • Gil, Eduardo
  • Bailón, Raquel
Heart rate variability (HRV) has been studied for decades in clinical environments. Currently, the exponential growth of wearable devices in health monitoring is leading to new challenges that need to be solved. These devices have relatively poor signal quality and are affected by numerous motion artifacts, with data loss being the main stumbling block for their use in HRV analysis. In the present paper, it is shown how data loss affects HRV metrics in the time domain and frequency domain and Poincaré plots. A gap-filling method is proposed and compared to other existing approaches to alleviate these effects, both with simulated (16 subjects) and real (20 subjects) missing data. Two different data loss scenarios have been simulated: (i) scattered missing beats, related to a low signal to noise ratio; and (ii) bursts of missing beats, with the most common due to motion artifacts. In addition, a real database of photoplethysmography-derived pulse detection series provided by Apple Watch during a protocol including relax and stress stages is analyzed. The best correction method and maximum acceptable missing beats are given. Results suggest that correction without gap filling is the best option for the standard deviation of the normal-to-normal intervals (SDNN), root mean square of successive differences (RMSSD) and Poincaré plot metrics in datasets with bursts of missing beats predominance (p<0.05), whereas they benefit from gap-filling approaches in the case of scattered missing beats (p<0.05). Gap-filling approaches are also the best for frequency-domain metrics (p<0.05). The findings of this work are useful for the design of robust HRV applications depending on missing data tolerance and the desired HRV metrics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Reliability of pulse photoplethysmography sensors: Coverage using different setups and body locations

  • Armañac-Julián, Pablo
  • Kontaxis, Spyridon
  • Rapalis, Andrius
  • Marozas, Vaidotas
  • Laguna, Pablo
  • Bailón, Raquel
  • Gil, Eduardo
  • Lázaro, Jesús
Pulse photoplethysmography (PPG) is a simple and economical technique for obtaining cardiovascular information. In fact, PPG has become a very popular technology among wearable devices. However, the PPG signal is well-known to be very vulnerable to artifacts, and a good quality signal cannot be expected for most of the time in daily life. The percentage of time that a given measurement can be estimated (e.g., pulse rate) is denoted coverage (C), and it is highly dependent on the subject activity and on the configuration of the sensor, location, and stability of contact. This work aims to quantify the coverage of PPG sensors, using the simultaneously recorded electrocardiogram as a reference, with the PPG recorded at different places in the body and under different stress conditions. While many previous works analyzed the feasibility of PPG as a surrogate for heart rate variability analysis, there exists no previous work studying coverage to derive other cardiovascular indices. We report the coverage not only for estimating pulse rate (PR) but also for estimating pulse arrival time (PAT) and pulse amplitude variability (PAV). Three different datasets are analyzed for this purpose, consisting of a tilt-table test, an acute emotional stress test, and a heat stress test. The datasets include 19, 120, and 51 subjects, respectively, with PPG at the finger and at the forehead for the first two datasets and at the earlobe, in addition, for the latter. C ranges from 70% to 90% for estimating PR. Regarding the estimation of PAT, C ranges from 50% to 90%, and this is very dependent on the PPG sensor location, PPG quality, and the fiducial point (FP) chosen for the delineation of PPG. In fact, the delineation of the FP is critical in time for estimating derived series such as PAT due to the small dynamic range of these series. For the estimation of PAV, the C rates are between 70% and 90%. In general, lower C rates have been obtained for the PPG at the forehead. No difference in C has been observed between using PPG at the finger or at the earlobe. Then, the benefits of using either will depend on the application. However, different C rates are obtained using the same PPG signal, depending on the FP chosen for delineation. Lower C is reported when using the apex point of the PPG instead of the maximum flow velocity or the basal point, with a difference from 1% to even 10%. For further studies, each setup should first be analyzed and validated, taking the results and guidelines presented in this work into account, to study the feasibility of its recording devices with respect to each specific application.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Atrial fibrosis identification with unipolar electrogram eigenvalue distribution analysis in multi-electrode arrays

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher, Sara
  • Martinez-Mateu, Laura
  • Saiz, Javier
  • Invers-Rubio, Eric
  • Guillem, Maria S.
  • Martínez, Juan Pablo
  • Laguna, Pablo
Atrial fbrosis plays a key role in the initiation and progression of atrial fbrillation (AF). Atrial fbrosis is typically identifed by a peak-to-peak amplitude of bipolar electrograms (b-EGMs) lower than 0.5 mV, which may be considered as ablation targets. Nevertheless, this approach disregards signal spatiotemporal information and b-EGM sensitivity to catheter orientation. To overcome these limitations, we propose the dominant-to-remaining eigenvalue dominance ratio (EIGDR) of unipolar electrograms (u-EGMs) within neighbor electrode cliques as a waveform dispersion measure, hypothesizing that it is correlated with the presence of fbrosis. A simulated 2D tissue with a fbrosis patch was used for validation. We computed EIGDR maps from both original and time-aligned u-EGMs, denoted as R and RA, respectively, also mapping the gain in eigenvalue concentration obtained by the alignment, ΔRA. The performance of each map in detecting fbrosis was evaluated in scenarios including noise and variable electrode-tissue distance. Best results were achieved by RA, reaching 94% detection accuracy, versus the 86% of b-EGMs voltage maps. The proposed strategy was also tested in real u-EGMs from fbrotic and non-fbrotic areas over 3D electroanatomical maps, supporting the ability of the EIGDRs as fbrosis markers, encouraging further studies to confrm their translation to clinical settings.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Ventilatory Thresholds Estimation Based on ECG-derived Respiratory Rate

  • Garcia, Diego
  • Kontaxis, Spyridon
  • Hernandez-Vicente, Adrian
  • Hernando, David
  • Milagro, Javier
  • Pueyo, Esther
  • Garatachea, Nuria
  • Bailon, Raquel
  • Lazaro, Jesus
The purpose of this work is to study the feasibility of estimating the first and second ventilatory thresholds (VT1 and VT2, respectively) by using electrocardiogram (ECG)-derived respiratory rate during exercise testing. The ECGs of 25 healthy volunteers during cycle ergometer exercise test with increasing workload were analyzed. Time-varying respiratory rate was estimated from an ECG-derived respiration signal obtained from QRS slopes' range method. VT1 and VT2 were estimated as the points of maximum change in respiratory rate slope using polynomial spline smoothing. Reference VT1 and VT2 were determined from the ventilatory equivalents of O2 and CO2. Estimation errors (in watts) of -13.96 (54.84) W for VT1 and -8.06 (39.63) Wfor VT2 (median (interquartile range)) were obtained, suggesting that ventilatory thresholds can be estimated from solely the ECG signal.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A meshless fragile points method for rule-based definition of myocardial fiber orientation

  • Mountris, Konstantinos A.
  • Pueyo, Esther
Background and objective: Rule-based methods are commonly used to estimate the arrangement of myocardial fibers by solving the Laplace problem with appropriate Dirichlet boundary conditions. Existing algorithms are using the Finite Element Method (FEM) to solve the Laplace–Dirichlet problem. However, meshless methods are under development for cardiac electrophysiology simulation. The objective of this work is to propose a meshless rule based method for the determination of myocardial fiber arrangement without requiring a mesh discretization as it is required by FEM. Methods: The proposed method employs the Fragile Points Method (FPM) for the solution of the Laplace–Dirichlet problem. FPM uses simple discontinuous trial functions and single-point exact integration for linear trial functions that set it as a promising alternative to the Finite Element Method. We derive the FPM formulation of the Laplace–Dirichlet and we estimate ventricular and atrial fiber arrangements according to rules based on histology findings for four different geometries. The obtained fiber arrangements from FPM are compared with the ones obtained from FEM by calculating the angle between the fiber vector fields of the two methods for three different directions (i.e., longitudinal, sheet, transverse). Results:The fiber arrangements that were generated with FPM were in close agreement with the generated arrangements from FEM for all three directions. The mean angle difference between the FPM and FEM vector fields were lower than for the ventricular fiber arrangements and lower than for the atrial fiber arrangements. Discussion:The proposed meshless rule-based method was proven to generate myocardial fiber arrangements with very close agreement with FEM while alleviates the requirement for a mesh of the latter. This is of great value for cardiac electrophysiology solvers that are based on meshless methods since they require a well defined myocardial fiber arrangement to simulate accurately the propagation of electrical signals in the heart. Combining a meshless solution for both the determination of the fibers and the electrical signal propagation can allow for solution that do not require the definition of a mesh. To our knowledge, this work is the first one to propose a meshless rule-based method for myocardial fiber arrangement determination.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Blunted autonomic reactivity to mental stress in depression quantified by nonlinear cardiorespiratory coupling indices

  • Kontaxis, Spyridon
  • Laguna, Pablo
  • García Pages, Esther
  • Posadas-de Miguel, Mar
  • Siddi, Sara
  • Luisa Bernal, Maria
  • Maria Haro, Josep
  • Aguiló, Jordi
  • de la Camara, Concepción
  • Bailón, Raquel
  • Gil, Eduardo
In this study, differences in autonomic reactivity to mental stress between Major Depressive Disorder (MDD) patients and healthy control (HC) subjects are assessed by nonlinear cardiorespiratory coupling indices derived from the Real Wavelet Biphase. The degree and strength of Quadratic Phase Coupling (QPC) between interacting oscillations of Heart Rate Variability (HRV) and respiration are quantified before, during and after the execution of acognitive task. Results show that the QPC strength and QPC degree between the respiration and the respiratory sinus arrhythmia component of HRV were lower in HC compared to MDD during stress, suggesting that the parasympathetic branch was less inhibited in MDD patients. During recovery, only in HC group, this degree of QPC increased, while the respiratory rate was reduced, compared to the basal stage. The degree of QPC between the respiration and components of HRV in the low frequency band ([0.04, 0.15] Hz) increased in HC during stress, compared to the basal stage, while remained unchanged in MDD patients. These results imply that depression is associated with blunted autonomic reactivity to mental stress
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The role of ß-adrenergic stimulation in QT interval adaptation to heart rate during stress test

  • Pérez, Cristina
  • Cebollada, Rubén
  • Mountris, Konstantinos A.
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Pueyo, Esther
The adaptation lag of the QT interval after heart rate (HR) has been proposed as an arrhythmic risk marker. Most studies have quantified the QT adaptation lag in response to abrupt, step-like changes in HR induced by atrial pacing, in response to tilt test or during ambulatory recordings. Recent studies have introduced novel methods to quantify the QT adaptation lag to gradual, ramp-like HR changes in stress tests by evaluating the differences between the measured QT series and an estimated, memoryless QT series obtained from the instantaneous HR. These studies have observed the QT adaptation lag to progressively reduce when approaching the stress peak, with the underlying mechanisms being still unclear. This study analyzes the contribution of β-adrenergic stimulation to QT interval rate adaptation in response to gradual, ramp-like HR changes. We first quantify the QT adaptation lag in Coronary Artery Disease (CAD) patients undergoing stress test. To uncover the involved mechanisms, we use biophysically detailed computational models coupling descriptions of human ventricular electrophysiology and β-adrenergic signaling, from which we simulate ventricular action potentials and ECG signals. We characterize the adaptation of the simulated QT interval in response to the HR time series measured from each of the analyzed CAD patients. We show that, when the simulated ventricular tissue is subjected to a time-varying β-adrenergic stimulation pattern, with higher stimulation levels close to the stress peak, the simulated QT interval presents adaptation lags during exercise that are more similar to those measured from the patients than when subjected to constant β-adrenergic stimulation. During stress test recovery, constant and time-varying β-adrenergic stimulation patterns render similar adaptation lags, which are generally shorter than during exercise, in agreement with results from the patients. In conclusion, our findings support the role of time-varying β-adrenergic stimulation in contributing to QT interval adaptation to gradually increasing HR changes as those seen during the exercise phase of a stress test.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Atrial fibrillation episode patterns as predictor of clinical outcome of catheter ablation

  • Saiz Vivó, Javier
  • Corino, Valentina D. A.
  • Martín Yebra, Alba
  • Mainardi, Luca T.
  • Hatala, Robert
  • Sörnmo, Leif
Methods for characterization of atrial fibrillation (AF) episode patterns have been introduced without establishing clinical significance. This study investigates, for the first time, whether post-ablation recurrence of AF can be predicted by evaluating episode patterns. The dataset comprises of 54 patients (age 56 ± 11 years; 67% men), with an implantable cardiac monitor, before undergoing the first AF catheter ablation. Two parameters of the alternating bivariate Hawkes model were used to characterize the pattern: AF dominance during the monitoring period (log(mu)) and temporal aggregation of episodes (beta1). Moreover, AF burden and AF density, a parameter characterizing aggregation of AF burden, were studied. The four parameters were computed from an average of 29 AF episodes before ablation. The risk of AF recurrence after catheter ablation using the Hawkes parameters log(mu) and beta1, AF burden, and AF density was evaluated. While the combination of AF burden and AF density is related to a non-significant hazard ratio, the combination of log(mu) and beta1 is related to a hazard ratio of 1.95 (1.03–3.70; p < 0.05). The Hawkes parameters showed increased risk of AF recurrence within 1 year after the procedure for patients with high AF dominance and high episode aggregation and may be used for pre-ablation risk assessment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Enhancing safety in hyperbaric environments through analysis of autonomic nervous system responses: a comparison of dry and humid conditions

  • Sánchez, Carlos
  • Hernando, Alberto
  • Bolea, Juan
  • Izquierdo, David
  • Rodríguez, Germán
  • Olea, Agustín
  • Lozano, María Teresa
  • Peláez-Coca, María Dolores
Diving can have significant cardiovascular effects on the human body and increase the risk of developing cardiac health issues. This study aimed to investigate the autonomic nervous system (ANS) responses of healthy individuals during simulated dives in hyperbaric chambers and explore the effects of the humid environment on these responses. Electrocardiographic- and heart-rate-variability (HRV)-derived indices were analyzed, and their statistical ranges were compared at different depths during simulated immersions under dry and humid conditions. The results showed that humidity significantly affected the ANS responses of the subjects, leading to reduced parasympathetic activity and increased sympathetic dominance. The power of the high-frequency band of the HRV after removing the influence of respiration, PHF⊥¯, and the number of pairs of successive normal-to-normal intervals that differ by more than 50 ms divided by the total number of normal-to-normal intervals, pNN50¯, indices were found to be the most informative in distinguishing the ANS responses of subjects between the two datasets. Additionally, the statistical ranges of the HRV indices were calculated, and the classification of subjects as “normal” or “abnormal” was determined based on these ranges. The results showed that the ranges were effective at identifying abnormal ANS responses, indicating the potential use of these ranges as a reference for monitoring the activity of divers and avoiding future immersions if many indices are out of the normal ranges. The bagging method was also used to include some variability in the datasets’ ranges, and the classification results showed that the ranges computed without proper bagging represent reality and its associated variability. Overall, this study provides valuable insights into the ANS responses of healthy individuals during simulated dives in hyperbaric chambers and the effects of humidity on these responses.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Otros (Other)

Advances in Wearable Photoplethysmography Applications in Health Monitoring

  • Nardelli, Mimma
  • Bailón, Raquel
In the last few years, interest in wearable technology for physiological signal monitoring is rapidly growing, especially during and after the COVID-19 pandemic.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Decomposing photoplethysmogram waveforms into systolic and diastolic waves, with application to hyperbaric environments

  • Hernando, Alberto
  • Peláez-Coca, María Dolores
  • Gil, Eduardo
Objective: A new algorithm to decompose the photoplethysmogram (PPG) pulse in two waves related with the systolic and diastolic parts, was applied to identify alterations in the morphology of the PPG pulse due to the pressure. Approach: Each pulse was decomposed into two waves: the first one a Gaussian related with the systolic peak, and the second one was modelled as a lognormal curve associated with the diastolic part. From these two waves, 13 parameters related with the width (W1, W2 and W2/W1), the time instant (T1, T2, T21, TBB), the amplitude (A1, A2, A2/A1) and the areas (D1, D2, D2/D1) were estimated. These parameters were computed from subjects inside a hyperbaric chamber, involving five stages at different pressure: 1 atm, 3 atm, 5 atm, 3 atm and 1 atm. Main results: There was a significant increase in the values of A1, A2, W1, T1, and D1, and a decrease in the ratios when the pressure increased, that suggest a vasoconstriction when the pressure increased. There is also an increase in the values of , T2, T12, and W2 along the protocol, that implies a dependency of some parameters with the pulse-to-pulse interval. Significance: This methodology allows extracting a large set of parameters related with the PPG morphology that are affected by the change of pressure inside hyperbaric environments.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG ventricular repolarization dynamics during exercise: Temporal profile, relation to heart rate variability and effects of age and physical health

  • Hernández-Vicente, Adrián
  • Hernando, David
  • Vicente-Rodríguez, Germán
  • Bailón, Raquel
  • Garatachea, Nuria
  • Pueyo, Esther
Periodic repolarization dynamics (PRD) is a novel electrocardiographic marker of cardiac repolarization instability with powerful risk stratification capacity for total mortality and sudden cardiac death. Here, we use a time-frequency analysis approach to continuously quantify PRD at rest and during exercise, assess its dependence on heart rate variability (HRV) and characterize the effects of age (young adults/middle-aged adults/older adults), body mass index (non-overweight/overweight) and cardiorespiratory fitness level (fit/unfit). Sixty-six male volunteers performed an exercise test. RR and dT variabilities (RRV, dTV), as well as the fraction of dT variability unrelated to RR variability, were computed based on time-frequency representations. The instantaneous LF power of dT (PdTV), representing the same concept as PRD, and of its RRV-unrelated component (PdTVuRRV) were quantified. dT angle was found to mostly oscillate in the LF band. Overall, 50-70% of PdTV was linearly unrelated to RRV. The onset of exercise caused a sudden increase in PdTV and PdTVuRRV, which returned to pre-exercise levels during recovery. Clustering analysis identified a group of overweight and unfit individuals with significantly higher PdTV and PdTVuRRV values at rest than the rest of the population. Our findings shed new light on the temporal profile of PRD during exercise, its relationship to HRV and the differences in PRD between subjects according to phenotypic characteristics. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Acute Cardiorespiratory Coupling Impairment in Worsening Sleep Apnea-Related Intermittent Hypoxemia

  • Hietakoste, Salla
  • Armañac-Julián, Pablo
  • Karhu, Tuomas
  • Bailón, Raquel
  • Sillanmäki, Saara
  • Töyräs, Juha
  • Leppänen, Timo
  • Myllymaa, Sami
  • Kainulainen, Samu
Objective: Hypoxic load is one of the main characteristics of obstructive sleep apnea (OSA) contributing to sympathetic overdrive and weakened cardiorespiratory coupling (CRC). Whether this association changes with increasing hypoxic load has remained obscure. Therefore, we aimed to study our hypothesis that increasing hypoxic load acutely decreases the CRC. Methods: We retrospectively analyzed the electrocardiography and nasal pressure signals in 5-min segment pairs ( n = 36 926) recorded during clinical polysomnographies of 603 patients with suspected OSA. The segment pairs were pooled into five groups based on the hypoxic load severity described with the the total integrated area under the blood oxygen saturation curve during desaturations. In these severity groups, we determined the frequency-domain heart rate variability (HRV) parameters, the HRV and respiratory high-frequency (HF, 0.15–0.4 Hz) peaks, and the difference between those peaks. We also computed the spectral HF coherence between HRV and respiration in the HF band. Results: The ratio of low-frequency (LF, 0.04–0.15 Hz) to HF power increased from 1.047 to 1.805 ( p < 0.001); the difference between the HRV and respiratory HF peaks increased from 0.001 Hz to 0.039 Hz ( p < 0.001); and the spectral coherence between HRV and respiration in the HF band decreased from 0.813 to 0.689 ( p < 0.001) as the hypoxic load increased. Conclusion and Significance: The vagal modulation decreases and CRC weakens significantly with increasing hypoxic load. Thus, the hypoxic load could be utilized more thoroughly in contemporary OSA diagnostics to better assess the severity of OSA-related cardiac stress.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Hypoxaemic load in sleep apnoea is associated with acute changes in T-wave amplitude

  • Sillanmäki, Saara
  • Ebrahimian, Serajeddin
  • Hietakoste, Salla
  • Hernando, David
  • Bailon, Raquel
  • Leppänen, Timo
  • Kainulainen, Samu
AimsObstructive sleep apnoea (OSA) imposes significant stress on the cardiovascular system and the heart. While long-term cardiac effects are understood, the immediate impact of hypoxaemia on the heart's electrophysiology lacks understanding. Our study aims to explore desaturation severity on cardiovascular repolarisation.MethodsWe retrospectively analysed ECGs from full diagnostic polysomnographies from 492 patients with suspected OSA. The analyses were conducted before, during and after 9137 nocturnal apnoea- or hypopnoea-related desaturations. The mean andsdof T-wave amplitude change from the baseline level to the level during and after desaturations (ΔTamp_meanand ΔTamp_SD) were calculated. To investigate the modulatory effects of desaturation severity, the data were divided into subgroups based on the desaturation duration (Tdes; 10 s≤Tdes<20 s, 20 s≤Tdes<30 s, 30 s≤Tdes<45 s and Tdes≥45 s) and magnitude of blood oxygen saturation drop (change in peripheral oxygen saturation (ΔSpO2); 3%≤ΔSpO2<4.5%, 4.5%≤ΔSpO2<6%, 6%≤ΔSpO2<7.5% and ΔSpO2≥7.5%) for men and women.ResultsDesaturations caused significant (p<0.01) changes in ΔTamp_meanduring and after desaturations. In men, the median ΔTamp_meanduring and after deep (ΔSpO2≥7.5%) desaturations were 21 µV and 24 µV, respectively. In women, the median ΔTamp_meanin deep desaturations was 15 µV during and 21 µV after desaturations. Similarly, the ΔTamp_SDincreased during and after deep desaturations. In regression analysis, the desaturation depth was an independent predictor for ventricular repolarisation instability.ConclusionWe found an association between the severity of nocturnal desaturations and cardiac repolarisation instability. These findings hold particular importance, as repolarisation instability has been linked with cardiovascular morbidity and could potentially serve as a trigger for arrhythmias and sudden cardiac death.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmographic Waveform and Pulse Rate Variability Analysis in Hyperbaric Environments

  • Peláez-Coca, Mª Dolores
  • Hernando, Alberto
  • Lozano, Mª Teresa
  • Sánchez, Carlos
  • Izquierdo, David
  • Gil, Eduardo
The main aim of this work is to identify alterations in the morphology of the pulse photoplethysmogram (PPG) signal, due to the exposure of the subjects to a hyperbaric environment. Additionally, their Pulse Rate Variability (PRV) is analysed to characterise the response of their Autonomic Nervous System (ANS). To do that, 28 volunteers are introduced into a hyperbaric chamber and five sequential stages with different atmospheric pressures (1 atm; descent to 3 and 5 atm; ascent to 3 and 1 atm) are performed. In this work, nineteen morphological parameters of the PPG signal are analysed: the amplitude of the PPG pulse; eight parameters related to pulse width; eight parameters related to pulse area; and the two slopes of the PPG pulse. Also, classical time and frequency parameters of PRV are computed. The relative change of all the parameters was calculated with respect to the initial baseline state at 1 atm. Notable widening of the pulses width is observed in the four stages analysed, together with a decrease in the PPG amplitude at the last ascent stages. The PPG area increases with pressure, with no significant changes when the initial pressure is recovered. These changes in PPG waveform may be caused by an increase in the systemic vascular resistance as a consequence of vasoconstriction. This phenomenon suggests a sympathetic activation, causing a vasoconstriction in the skin circulation, especially in the extremities. However, the PRV results show an augmented parasympathetic activity and a reduction in the parameters that characterise the sympathetic response. So, only a sympathetic activation is detected in the peripheral region, as reflected by PPG morphology. The information regarding the ANS and the cardiovascular response that can be extracted from the PPG signal, as well as its compatibility with wet conditions make this signal the most suitable for studying the physiological response in hyperbaric environments, including scuba diving activities.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Detection of Walk Tests in Free-Living Activities Using a Wrist-Worn Device

  • Sokas D.
  • Paliakaite B.
  • Rapalis A.
  • Marozas V.
  • Bailón R.
  • Petrenas A.
Exercise testing to assess the response to physical rehabilitation or lifestyle interventions is administered in clinics thus at best can be repeated only few times a year. This study explores a novel approach to collecting information on functional performance through walk tests, e.g., a 6-min walk test (6MWT), unintentionally performed in free-living activities. Walk tests are detected in step data provided by a wrist-worn device. Only those events of minute-to-minute variation in walking cadence, which is equal or lower than the empirically determined maximal SD (e.g., 5-steps), are considered as walk test candidates. Out of detected walk tests within the non-overlapping sliding time interval (e.g., 1-week), the one with the largest number of steps is chosen as the most representative. This approach is studied on a cohort of 99 subjects, assigned to the groups of patients with cardiovascular disease (CVD) and healthy subjects below and over 40-years-old, who were asked to wear the device while maintaining their usual physical activity regimen. The total wear time was 8, 864 subject-days after excluding the intervals of occasionally discontinued monitoring. About 82% (23/28) of patients with CVD and 88% (21/24) of healthy subjects over 40-years-old had at least a single 6MWT over the 1st month of monitoring. About 52% of patients with CVD (12/23) and 91% (19/21) of healthy subjects over 40-years-old exceeded 500 m. Patients with CVD, on average, walked 46 m shorter 6MWT distance (p = 0.04) compared to healthy subjects. Unintentional walk testing is feasible and could be valuable for repeated assessment of functional performance outside the clinical setting. © Copyright © 2021 Sokas, Paliakaite, Rapalis, Marozas, Bailón and Petrenas.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Model-Based Evaluation of Methods for Respiratory Sinus Arrhythmia Estimation

  • Morales J.
  • Moeyersons J.
  • Armanac P.
  • Orini M.
  • Faes L.
  • Overeem S.
  • Van Gilst M.
  • Van Dijk J.
  • Van Huffel S.
  • Bailon R.
  • Varon C.
Objective: Respiratory sinus arrhythmia (RSA) refers to heart rate oscillations synchronous with respiration, and it is one of the major representations of cardiorespiratory coupling. Its strength has been suggested as a biomarker to monitor different conditions, and diseases. Some approaches have been proposed to quantify the RSA, but it is unclear which one performs best in specific scenarios. The main objective of this study is to compare seven state-of-the-art methods for RSA quantification using data generated with a model proposed to simulate, and control the RSA. These methods are also compared, and evaluated on a real-life application, for their ability to capture changes in cardiorespiratory coupling during sleep. Methods: A simulation model is used to create a dataset of heart rate variability, and respiratory signals with controlled RSA, which is used to compare the RSA estimation approaches. To compare the methods objectively in real-life applications, regression models trained on the simulated data are used to map the estimates to the same measurement scale. Results, and conclusion: RSA estimates based on cross entropy, time-frequency coherence, and subspace projections showed the best performance on simulated data. In addition, these estimates captured the expected trends in the changes in cardiorespiratory coupling during sleep similarly. Significance: An objective comparison of methods for RSA quantification is presented to guide future analyses. Also, the proposed simulation model can be used to compare existing, and newly proposed RSA estimates.