Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 20
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Copper underpotential deposition at gold surfaces in contact with a deep eutectic solvent: New insights

  • Sebastián, Paula
  • Gómez, Elvira
  • Climent, Victor
  • Feliu, Juan M.
  • Climent, Victor|||/items/f8d596b7-a0df-492d-8e11-794f68d84268
The electrodeposition of copper on a polycrystalline gold electrode and on Au(hkl) single crystals was investigated in a deep eutectic solvent (DES). The DES employed consisted of a mixture of choline chloride and urea (1:2). The Au(hkl)/DES interface was studied using cyclic voltammetry in the capacitive region. The blank voltammograms showed characteristic features, not previously reported, that demonstrate the surface sensitivity of this solvent. Copper electrodeposition was then studied and it was found that this takes place through the formation of an underpotential deposition (UPD) adlayer, demonstrating the surface sensitivity of this process. Voltammetric profiles showed similarities with those obtained in aqueous solutions containing chloride, suggesting that the copper UPD in this DES is strongly influenced by the presence of chloride.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Surface Sensitive Nickel Electrodeposition in Deep Eutectic Solvent

  • Sebastián, Paula
  • Giannotti, Marina Inés
  • Gómez, Elvira
  • Feliu, Juan M.
The first steps of nickel electrodeposition in a deep eutectic solvent (DES) are analyzed in detail. Several substrates from glassy carbon to Pt(111) were investigated pointing out the surface sensitivity of the nucleation and growth mechanism. For that, cyclic voltammetry and chronoamperometry, in combination with scanning electron microscopy (SEM), were employed. X-ray diffraction (XRD) and atomic force microscopy (AFM) were used to more deeply analyze the Ni deposition on Pt substrates. In a 0.1 M NiCl2 + DES solution (at 70 °C), the nickel deposition on glassy carbon takes place within the potential limits of the electrode in the blank solution. Although, the electrochemical window of Pt|DES is considerably shorter than on glassy carbon|DES, it was still sufficient for the nickel deposition. On the Pt electrode, the negative potential limit was enlarged while the nickel deposit grew, likely because of the lower catalytic activity of the nickel toward the reduction of the DES. At lower overpotentials, different hydrogenated Ni structures were favored, most likely because of the DES co-reduction on the Pt substrate. Nanometric metallic nickel grains of rounded shape were obtained on any substrate, as evidenced by the FE-SEM. Passivation phenomena, related to the formation of Ni oxide and Ni hydroxylated species, were observed at high applied overpotentials. At low deposited charge, on Pt(111) the AFM measurements showed the formation of rounded nanometric particles of Ni, which rearranged and formed small triangular arrays at sufficiently low applied overpotential. This particle pattern was induced by the ⟨111⟩ orientation and related to surface sensitivity of the nickel deposition in DES. The present work provides deep insights into the Ni electrodeposition mechanism in the selected deep eutectic solvent.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Implementing thermometry on silicon surfaces functionalized by lanthanide-doped self-assembled polymer monolayers

  • Piñol, Rafael
  • Antorrena, Guillermo
  • Brites, Carlos
  • Silva, Nuno Joâo O.
  • Murillo, José Luis
  • Cases, Rafael
  • Díez, Isabel
  • Palacio, Fernando
  • Carlos, Luis D.
  • Millán, Ángel
The thermal gradients generated at submicrometer scale by the millions of transistors contained in integrated circuits are becoming the key limiting factor for device integration in micro- and nanoelectronics. Noncontact thermometric techniques with high-spatial resolution are, thus, essential for noninvasive off-chip characterization and heat management on Si surfaces. Here, the first ratiometric luminescent molecular thermometer implemented in a self-assembled polymer monolayer functionalized Si surface is reported. The functionalization of Si surfaces with luminescent thermometers constitutes a proof-of-concept that foretells a wide range of applications in Si-based micro- and nanostructures. The thermometric functionalization of the Si surface with Tb3+ and Eu3+ complexes leads to a thermal sensitivity up to 1.43% K−1, a cycle–recycle reliability of 98.6%, and a temperature uncertainty of less than 0.3 K. The functionalized surface presents reversible bistability that can be used as an optically active molecular demultiplexer., Financial support from the Spanish Ministry of Science and Innovation research grants BFU2009-12763/BFI, MAT2011-259911, TEC2011-29140, and TEC2014-51940, and Project Consolider-Ingenio in Molecular Nanoscience CSD2007-00010 are gratefully acknowledged. Moreover, the work was partially developed in the scope of the project CICECO − Aveiro Institute of Materials (Ref. FCT UID/CTM/50011/2013), financed by Portuguese funds through the FCT/MEC and when applicable cofinanced by FEDER under the PT2020 Partnership Agreement. C.D.S.B. and N.J.O.S. thank the Portuguese Fundação para a Ciência e Tecnologia (FCT) for their grants (SFRH/BPD/89003/2012 and IF/01653/2013, respectively)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Study of Galfenol direct cytotoxicity and remote microactuation in cells

  • Vargas-Estevez, Carolina
  • Blanquer, Andreu
  • Dulal, Prabesh
  • Pérez del Real, Rafael
  • Duch, Marta
  • Ibáñez, Elena
  • Barrios, Leonardo
  • Murillo Rodríguez, Gonzalo
  • Torras, Núria
  • Nogués, Carme
  • Stadler, Bethanie J. H.
  • Plaza, José Antonio
  • Esteve i Tintó, Jaume
Remote microactuators are of great interest in biology and medicine as minimally-invasive tools for cellular stimulation. Remote actuation can be achieved by active magnetostrictive transducers which are capable of changing shape in response to external magnetic fields thereby creating controlled displacements. Among the magnetostrictive materials, Galfenol, the multifaceted iron-based smart material, offers high magnetostriction with robust mechanical properties. In order to explore these capabilities for biomedical applications, it is necessary to study the feasibility of material miniaturization in standard fabrication processes as well as evaluate the biocompatibility. Here we develop a technology to fabricate, release, and suspend Galfenol-based microparticles, without affecting the integrity of the material. The morphology, composition and magnetic properties of the material itself are characterized. The direct cytotoxicity of Galfenol is evaluated in vitro using human macrophages, osteoblast and osteosarcoma cells. In addition, cytotoxicity and actuation of Galfenol microparticles in suspension are evaluated using human macrophages. The biological parameters analyzed indicate that Galfenol is not cytotoxic, even after internalization of some of the particles by macrophages. The microparticles were remotely actuated forming intra- and extracellular chains that did not impact the integrity of the cells. The results propose Galfenol as a suitable material to develop remote microactuators for cell biology studies and intracellular applications., This study was supported by the Spanish Government through the project MINAHE 5 (No. TEC2014-51940-C1) and ENVBIOPORAL (No. MAT2014-57960-C3-3-R), the predoctoral FPI grant (No. BES- 2012-052105), the NANONEURO project PIE201350E110 (CSIC) and the Generalitat de Catalunya (2014-SGR-524). A.B. was supported by a predoctoral grant from the Universitat Aut onoma de Barcelona. We wish to thank as well the IMB-CNM Clean Room (Barcelona, Spain), Prof. William P. Robbins of University of Minnesota (Minneapolis, USA) for his support to perform the magnetostrictive measurements and the Institute for Rock Magnetism (Minneapolis, USA) for its facilities., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effective ionic-liquid microemulsion based electrodeposition of mesoporous Co-Pt films for methanol oxidation catalysis in alkaline media

  • Serrà, Albert
  • Gómez, Elvira
  • Golosovsky, Igor V.
  • Nogués, Josep
  • Vallés, Elisa
Pt-based direct methanol fuel cells are attracting increasing interest as environmentally friendly alternative energy sources. However, the high price of Pt and the difficulty to prepare favourable morphologies for catalysis (e.g., mesoporous materials) are hampering their development into feasible products. Here, we demonstrate a novel approach to efficiently grow mesoporous films of Pt-poor alloys (CoPt and CoPt), based on electrodeposition in ionic liquid-in-water (IL/W) microemulsions. The high proportion of the electrolytic aqueous solution in the IL/W microemulsion favors a significant deposition rate, while the presence of IL drops induces the formation of highly mesoporous films. The mesoporous alloys, with pores in the 8-11 nm range, exhibit excellent durability in acidic and alkaline aggressive media, maintaining their peculiar morphology. The structures are very efficient for the catalysis of methanol electro-oxidation in alkaline media, with minimal poisoning of the catalysts. These results pave the way to develop simple, versatile environmentally friendly fuel cell catalysts to commercialize new viable ecological alternative energy sources., This work was supported by the EU ERDF (FEDER) fund and the Spanish Government grant TEC2014-51940-C2-2-R from Ministerio de Economía y Competitividad (MINECO). The partial support from the 2014-SGR-1015 project from the Generalitat de Catalunya and the Russian grants RFBR 16-02-00058 and RG14.B25.31.0025 is also acknowledged. A. S. thanks the Ministerio de Educación, Cultura y Deporte for a predoctoral grant (FPU). The authors thank the CCiT-UB for the use of their equipment. ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Highly efficient electrochemical and chemical hydrogenation of 4-nitrophenol using recyclable narrow mesoporous magnetic CoPt nanowires

  • Serrà, Albert
  • Alcobé, Xavier
  • Sort, Jordi
  • Nogués, Josep
  • Vallés, Elisa
Toxic nitro-compounds, such as 4-nitrophenol, are one of the most common wastewater industrial pollutants. Thus, efficient ways to neutralize them are actively pursued. Here novel procedures to degrade these types of compounds based on the use of mesoporous magnetic nanowires are demonstrated. Fully-mesoporous magnetic narrow (25 nm) CoPt nanowires with an extraordinary effective area are grown using ionic liquid-in-water microemulsions in alumina templates. These mesoporous nanowires are shown to be efficient catalysts for the hydrogenation of 4-nitrophenol by electrocatalysis. Additionally, these nanowires also present exceptional conventional catalytic activity when used in conjunction with NaBH, particularly when magnetic stirring is utilized. In fact, magnetically actuated mesoporous CoPt nanowires drastically outperform all state-of-the-art 4-nitrophenol catalysts. Additionally, given their magnetic character, these nanowires can be easily recycled and reused. Thus, the outstanding catalytic performance of mesoporous CoPt nanowires makes them excellent candidates for wastewater treatment agents., This work was supported by the EU ERDF (FEDER) fund and the Spanish Government grants TEC2014-51940-C2-2-R and MAT2014-57960-C3-1-R from Ministerio de Economía y Competitividad (MINECO) –the latter cofinanced by FEDER. Partial funding from the European Research Council (Consolidator Grant, project n. 648454, SPIN-PORICS) and the Generalitat de Catalunya (2014-SGR-1015 project) is acknowledged. ICN2 acknowledges support from the Severo Ochoa Program (MINECO, Grant SEV-2013-0295)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Suspended Planar-Array Chips for Molecular Multiplexing atthe Microscale

  • Torras, Núria
  • Agusil, Juan Pablo
  • Vázquez, Patricia
  • Duch, Marta
  • Hernández-Pinto, Alberto M.
  • Samitier, Josep
  • De la Rosa, Enrique J.
  • Esteve, Jaume
  • Suárez González, Teresa
  • Pérez-García, Lluïsa
  • Plaza, José Antonio
A novel suspended planar-array chips technology is described, which effectively allows molecular multiplexing using a single suspended chip to analyze extraordinarily small volumes. The suspended chips are fabricated by combining silicon-based technology and polymer-pen lithography, obtaining increased molecular pattern flexibility, and improving miniaturization and parallel production. The chip miniaturization is so dramatic that it permits the intracellular analysis of living cells., This work was supported by the EU ERDF (FEDER) funds and the Spanish Government grants TEC2011‐29140‐C03‐01/02 and TEC2014‐51940‐C2‐1/2. PV was supported by a JAE‐DOC contract (FSE funding)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Synthesis of graphene-based photocatalysts for water splitting by laser-induced doping with ionic liquids

  • Pérez del Pino, Ángel
  • González Campo, Arántzazu
  • Giraldo, Sandra
  • Peral, José
  • Gyorgy, Eniko
  • Logofatu, Constantin
  • deMello, Andrew J.
  • Puigmartí Luis, Josep
The synthesis of metal-free graphene-based photocatalysts has received great attention recently due to their expected contributions to the development of solar-based hydrogen generation via water-splitting in a low cost and ecological manner. In this work, a new method for the generation of nitrogen-doped graphene-based powder employing an alternative solution to commonly used toxic and hazardous organic solvents is presented. The procedure involves ultraviolet pulsed laser irradiation of graphene oxide (GO) flakes dispersed in 1-butyl-3-methylimidazolium [bmim]-based ionic liquids using both chloride and acetate anions. The structural and compositional analysis using transmission electron microscopy, X-ray photoelectron and infrared spectroscopy indicate that the irradiated GO becomes partially reduced and doped with graphitic, pyrrolic and pyridinic nitrogen species. Interestingly, the relative content of the nitrogen functionalities is controlled by the anion in the ionic liquid and its concentration, with the obtained graphene-based powders showing higher photocatalytic activity than GO. Furthermore, a remarkable synergistic effect is observed for GO-[bmim]-acetate powder (acting as co-catalyst) in combination with anatase TiO2 nanoparticles. The presented method opens new research avenues for the cost-effective mass production of graphene-based photocatalysts for water splitting applications., The authors thank the financial support of the Spanish Ministry of Economy, Industry and Competitiveness under the projects ENE2014-56109-C3-3-R and HIDROPILSOL (CTQ2013-47103-R), in addition to the MAT2016-77852-C2-1-R (AEI/FEDER, UE). JPL acknowledges funding from the Swiss National Science Foundation (the project no. 200021_160174) and the EU (ERC-2015-STG microCrysFact 677020). SG thanks to MINECO for a FPI predoctoral grant and the project TEC2014-51940-C2-2 (EU ERDF, FEDER). ICMAB acknowledges financial support from the Spanish Ministry of Economy, Industry and Competitiveness, through the “Severo Ochoa” Programme for Centres of Excellence in R&D (SEV- 2015- 0496). The authors also thank Dr. Nuria Aliaga and Ms.Wenjie Qian for their assistance in centrifugation and separation processes., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Silicon-nanowire based attachment of silicon chips for mouse embryo labelling

  • Durán, S.
  • Novo, S.
  • Duch, M.
  • Gómez-Martínez, Rodrigo
  • Fernández-Regúlez, Marta
  • San Paulo, A.
  • Nogués, C.
  • Esteve i Tintó, Jaume
  • Ibáñez, E.
  • Plaza, José Antonio
© 2015 The Royal Society of Chemistry. The adhesion of small silicon chips to cells has many potential applications as direct interconnection of the cells to the external world can be accomplished. Hence, although some typical applications of silicon nanowires integrated into microsystems are focused on achieving a cell-on-a-chip strategy, we are interested in obtaining chip-on-a-cell systems. This paper reports the design, technological development and characterization of polysilicon barcodes featuring silicon nanowires as nanoscale attachment to identify and track living mouse embryos during their in vitro development. The chips are attached to the outer surface of the Zona Pellucida, the cover that surrounds oocytes and embryos, to avoid the direct contact between the chip and the embryo cell membrane. Two attachment methodologies, rolling and pushpin, which allow two entirely different levels of applied forces to attach the chips to living embryos, are evaluated. The former consists of rolling the mouse embryos over one barcode with the silicon nanowires facing upwards, while in the latter, the barcode is pushed against the embryo with a micropipette. The effect on in vitro embryo development and the retention rate related to the calculated applied forces are stated. Field emission scanning electron microscopy inspection, which allowed high-resolution imaging, also confirms the physical attachment of the nanowires with some of them piercing or wrapped by the Zona Pellucida and revealed extraordinary bent silicon nanowires., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Nanometric metal-film thickness measurement based on a planar spiral coils stack

  • Vargas-Estevez, Carolina
  • Robaina, Roberto R.
  • Pérez del Real, Rafael
  • Plaza, José Antonio
This paper presents a sensor composed of a differential arrangement of coils capable ofmeasuring nanometric metallic film thickness. Experimental results achieved aluminum thickness measurements as lowas 20 nmwith a sensitivity of 3.8 mV/nm. This makes this sensor a flexible, nondestructive, and cheap alternative for metallic thickness measurement down to nanometric scale., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Technological development of intracellular polysilicon-chromium-gold chips for orthogonal chemical functionalization

  • Durán, S.
  • Duch, M.
  • Patiño, T.
  • Torres, A.
  • Penon, O.
  • Gómez-Martínez, Rodrigo
  • Barrios, Lizandra
  • Esteve i Tintó, Jaume
  • Nogués, C.
  • Pérez-García, L.
  • Plaza, José Antonio
© 2014 Elsevier B.V. Increasingly, advances in microtechnologies are focused on obtaining new chips intended for applications in fields such as nanomedicine and cell biology, taking advantage of the ability of microelectronics to manufacture devices with cell dimensions and a large variety of features. Here, we report a technology for the fabrication of multi-material chips, using polysilicon and gold as device layers, to be used as bi-functional cell-internalizable devices. In our case, one of the main technological challenges is to overcome the low adherence between these two materials, especially because of their small contact-area, only 9 μm2. Thus, in order to circumvent this difficulty a chromium adherent-layer was deposited in between. After fabrication, the devices following this design can be successfully internalized inside living macrophages without affecting their viability. The advantage of having multiple material layers in one device is the potential to render multi-tasking chips, as once they are appropriately functionalized, we can provide the chip the ability of being multi-functional. Hence, and as a proof of concept, two different proteins, Wheat Germ Agglutinin (WGA) and Concanavalin (ConA), were immobilized on the chip surface through self-assembled monolayers using orthogonal chemistry. The results of this work show a well-controlled fabrication, the bi-functional capabilities and no cell-toxicity of intracellular polysilicon-chromium-gold chips. Eventually, two different dyes (Oregon Green® 488 and BODIPY® 581/591) were used to bi-functionalize each surface of the multi-material chip in order to demonstrate that functional chips can also be internalized in living cells. These devices have a promising future as intracellular functional platforms for biosensing, drug delivery and diagnosis., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Combination of PDMS microfilters and micromixers based on flexible thermoplastic films for size sorting and mixing of microparticles

  • Lee, M.
  • Lopez-Martinez, M.J.
  • Baraket, Abdoullatif
  • Zine, N.
  • Esteve i Tintó, Jaume
  • Plaza, José Antonio
  • Ahmed, N.
  • Elaissari, Abdelhamid
  • Jaffrezic-Renault, Nicole
  • Errachid, Abdelhamid
© 2015 Wiley Periodicals, Inc. We present a study for the development of flexible microfilters based on sealing microstructured poly(dimethylsiloxane) (PDMS) to different functionalized thermoplastic films [polyimide (PI), polyethylene naphthalate (PEN), and polyethylene terephthalate (PET)]. The microfilter was manufactured by soft-lithography and replica molding and then combined with plasma activation and chemical treatment using 3-(aminopropyl)triethoxysilane (APTES). To demonstrate the functionality of the PDMS microfilters, poly(lactic-co-glycolic acid) (PLGA) microparticles (MPS) were filtered through the microfluidic device based on the three thermoplastic films. Subsequently, the mixing capabilities of a passive PDMS micromixer was observed with the injection of polymeric MPS (fluorescent and nonfluorescent) as fluidic mixers are not generally effective at mixing particles. On mixing nonfluorescent MPS (∼<10-30 μm in diameter) a mixing performance of 13.3% at 5 mm was observed. Therefore, a PDMS microfiltering device was integrated with a PDMS micromixer using a simple and cost effective home-made polymeric connector for filtration at a size sorting of 11 μm. The results exhibit that the combination of the two microfluidic devices can be achieved with size sorting and mixing of MPS with an improved mixing performance of 62.5% at 3 mm., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Traceability of human sperm samples by direct tagging with polysilicon microbarcodes

  • Novo, S.
  • Mora-Espí, I.
  • Gómez-Martínez, Rodrigo
  • Barrios, Lizandra
  • Ibáñez, E.
  • Such, X.
  • Duch, M.
  • Mora, X.
  • Plaza, José Antonio
  • Nogués, C.
© 2015 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved. The increasing number of patients undergoing assisted reproductive technology (ART) treatments and of cycles performed in fertility centres has led to some traceability errors. Although the incidence of mismatching errors is extremely low, any error is unacceptable, therefore different strategies have been developed to further minimize these errors, such as manual double-witnessing or electronic witnessing systems. More recently, our group developed a direct tagging method consisting of attaching microbarcodes directly to the zona pellucida of human oocytes/embryos. Here, this method is taken a step further by using these microbarcodes to tag human semen samples, demonstrating that the barcodes are not toxic and do not interfere in the selection of motile spermatozoa nor in the cryopreservation of the sperm samples. In addition, when this tagging system was applied to an animal model (rabbit), pregnancy rate and kitten viability were not affected., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Polysilicon-chromium-gold intracellular chips for multi-functional biomedical applications

  • Patiño, T.
  • Soriano, J.
  • Amirthalingam, E.
  • Durán, S.
  • González-Campo, Arántzazu
  • Duch, M.
  • Ibáñez, E.
  • Barrios, Lizandra
  • Plaza, José Antonio
  • Pérez-García, L.
  • Nogués, C.
The development of micro- and nanosystems for their use in biomedicine is a continuously growing field. One of the major goals of such platforms is to combine multiple functions in a single entity. However, achieving the design of an efficient and safe micro- or nanoplatform has shown to be strongly influenced by its interaction with the biological systems, where particle features or cell types play a critical role. In this work, the feasibility of using multi-material pSi-Cr-Au intracellular chips (MMICCs) for multifunctional applications by characterizing their interactions with two different cell lines, one tumorigenic and one non-tumorigenic, in terms of biocompatibility, internalization and intracellular fate, has been explored. Moreover, the impact of MMICCs on the induction of an inflammatory response has been assessed by evaluating TNFα, IL1b, IL6, and IL10 human inflammatory cytokines secretion by macrophages. Results show that MMICCs are biocompatible and their internalization efficiency is strongly dependent on the cell type. Finally as a proof-of-concept, MMICCs have been dually functionalized with transferrin and pHrodo™ Red, SE to target cancer cells and detect intracellular pH, respectively. In conclusion, MMICCs can be used as multi-functional devices due to their high biocompatibility, non-inflammatory properties and the ability of developing multiple functions., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Nanostructured materials for photodynamic therapy: synthesis, characterization and in vitro activity

  • Alea-Reyes, María E.
  • Rodrigues, M.
  • Serrà, A.
  • Mora, M.
  • Sagristá, M.L.
  • González, A.
  • Durán, S.
  • Duch, M.
  • Plaza, José Antonio
  • Vallés, E.
  • Russell, D.A.
  • Pérez-García, L.
Three nanostructured vehicles are proposed as potential carriers for photosensitizers to be used in photodynamic therapy: spherical nanoparticles, hexahedral microparticles and cylindrical magnetic nanorods. A comparative study of their photodynamic properties was performed, and the influence of their size and the amount of loaded porphyrin was considered to discuss their effects in the observed photodynamic activity. All the vehicles have a gold surface, allowing functionalization with a disulfide-containing porphyrin as the photosensitizer, as well as with a PEG-containing thiol to improve their biocompatibility and water solubility. The activity of the porphyrin loaded in each vehicle was assessed through in vitro photocytotoxicity studies using HeLa cells. A synergic effect for the porphyrin toxicity was observed in all of the vehicles. The zinc-containing porphyrin showed better production of singlet oxygen, and proved more photocytotoxic both in solution and loaded in any of the vehicles. The magnetism of the nanorods allows targeting with a magnetic field, but causes their aggregation, hampering the porphyrin's activity. Microparticles showed lower cell internalization but their bigger size allowed a high porphyrin loading, which translated into high photocytotoxicity. The highest cell internalization and photocytotoxicity was observed for the porphyrin-loaded nanoparticles, suggesting that a smaller size is favored in cell uptake., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Ultrasensitive photonic microsystem enabling sub-micrometric monitoring of arterial oscillations for advanced cardiovascular studies

  • Rodríguez-Rodríguez, Rosalía
  • Nils Ackermann, Tobias
  • Plaza, Jose Antonio
  • Simonsen, Ulf
  • Matchkov, Vladimir
  • Llobera, Andreu
  • Munoz-Berbel, Xavier
The research leading to these results has received funding from the GISCERV program (NGG-227, Ministerio de Economia y Competitividad) and SOAR project (Convocatoria 2015 de Ayudas Fundación BBVA a Investigadores y Creadores Culturales). This work was partially funded by the European Commission (Contract No. 317916, Liphos), Ministerio de Economía y Competitividad (MINAHE 5 MINECO/ICTI 2013–2016/TEC2014-51940-C2), and EU ERDF (FEDER) funds. XM-B was supported by the Ramón y Cajal program (Spanish Government). VM acknowledges funding from the Danish Heart Foundation (No. 4004-00102B) and the Novo Nordisk Foundation (No. NNF14OC001273). This work has made use of the Spanish ICTS Network MICRONANOFABS (Ministry of Economy, Industry and Competitiveness). We acknowledge support of the publication fee by the CSIC Open Access Publication Support Initiative through its Unit of Information Resources for Research (URICI)., Cardiovascular diseases are the first cause of death globally. Their early diagnosis requires ultrasensitive tools enabling the detection of minor structural and functional alterations in small arteries. Such analyses have been traditionally performed with video imaging-based myographs, which helped to investigate the pathophysiology of the microvessels. Since new vascular questions have emerged, substantial modifications are necessary to improve the performance of imaging and tracking software, reducing the cost and minimizing the microvessel cleaning and manipulation. To address these limitations, we present a photonic microsystem fabricated in polydimethylsiloxane and integrating micro-optical elements and a lightguide-cantilever for sub-micrometric analysis of small arteries (between 125 and 400μm of basal diameter). This technology enables simultaneous measurement of arterial distension, stiffness, vasomotion, and heartbeat and without the need for advanced imaging system. The microsystem has a limit of detection of 2μm, five times lower than video imaging-based myographs, is two times more sensitive than them (0.5 μm/mmHg), reduces variability to half and doubles the linear range reported in these myographs. More importantly, it allows the analysis of intact arteries preserving the integrity and function of surrounding tissues. Assays can be conducted in three configurations according to the surrounding tissue: (i) isolated arteries (in vitro) where the surrounding tissue is partially removed, (ii) non-isolated arteries (in vivo) with surrounding tissue partially removed, and (iii) intact arteries in vivo preserving surrounding tissue as well as function and integrity. This technology represents a step forward in the prediction of cardiovascular risk., info:eu-repo/semantics/acceptedVersion
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Highly efficient electrochemical and chemical hydrogenation of 4-nitrophenol using recyclable narrow mesoporous magnetic CoPt nanowires

  • Serrà, Albert|||0000-0003-0147-3400
  • Alcobé, Xavier
  • Sort, Jordi|||0000-0003-1213-3639
  • Nogués, Josep|||0000-0003-4616-1371
  • Vallés, Elisa
Toxic nitro-compounds, such as 4-nitrophenol, are one of the most common wastewater industrial pollutants. Thus, efficient ways to neutralize them are actively pursued. Here novel procedures to degrade this type of compounds based on the use of mesoporous magnetic nanowires are demonstrated. Fully-mesoporous magnetic narrow (25 nm) CoPt nanowires with an extraordinary effective area are grown by ionic liquid-in-water microemulsions in alumina templates. These mesoporous nanowires are shown to be efficient catalysts for the hydrogenation of 4-nitrophenol by electro-catalysis. Additionally, these nanowires also present an exceptional conventional catalytic activity when used in conjunction with NaBH4, particularly when magnetic stirring is utilized. In fact, magnetically actuated mesoporous CoPt nanowires drastically outperform all state-of-the-art 4-nitrophenol catalysts. Additionally, given their magnetic character, these nanowires can be easily recycled and reused. Thus, the outstanding catalytic performance of mesoporous CoPt nanowires makes them excellent candidates for wastewater treatment agents.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Magnetically-actuated mesoporous nanowires for enhanced heterogeneous catalysis

  • Serrà, Albert|||0000-0003-0147-3400
  • Grau Abarca, Sergi|||0000-0002-7035-4870
  • Gimbert-Suriñach, Carolina|||0000-0002-4412-7607
  • Sort, Jordi|||0000-0003-1213-3639
  • Nogués, Josep|||0000-0003-4616-1371
  • Vallés, Elisa
We study the optimization of the catalytic properties of entirely magnetic Co-Pt compact and mesoporous nanowires of different diameters (25-200 nm) by using magnetic actuation. The nanowires are a single-entity, robust, magnetic-catalyst with a huge catalytically-active surface area. We show that apart from conventional parameters, like the size and morphology of the nanowires, other factors can be optimized to enhance their catalytic activity. In particular, given the magnetic character of the nanowires, rotating magnetic fields are a very powerful approach to boost the performance of the catalyst. In particular, the magnetic field induces them to act as nano-stirrers, improving the local flow of material towards the active sites of the catalyst. We demonstrate the versatility of the procedure by optimizing (i) the degradation of different types of pollutants (4-nitrophenol and methylene blue) and (ii) hydrogen production. For example, by using as little as 0.1 mg mL⁻¹ of 25 nm wide Co-Pt mesoporous nanowires (with ∼3 nm pore size) as catalysts, kinetic normalized constants knor as high as 20,667 and 21,750 s⁻¹ g⁻¹ for 4-nitrophenol and methylene blue reduction, respectively, are obtained. In addition, activity values for hydrogen production from borohydride are as high as 25.0 L H₂ g⁻¹ min⁻¹, even at room temperature. These values outperform any current state-of-the-art proposed catalysis strategies for water remediation reactions by at least 10-times and are superior to most advanced approaches to generate hydrogen from borohydride. The recyclability of the nanowires together with the simplicity of the synthetic method makes this approach (using not only Co-Pt, but also other mesoporous magnetic catalysts) very appealing for very diverse types of catalytic applications.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Asymmetrically coupled resonators for mass sensing

  • Márquez, Salomón|||0000-0001-8434-6778
  • Alvarez, Mar|||0000-0003-4590-4401
  • Plaza, José A.|||0000-0002-8595-5580
  • Villanueva, Luis Guillermo|||0000-0003-3340-2930
  • Dominguez, Carlos|||0000-0002-5972-7285
  • Lechuga, Laura M.|||0000-0001-5187-5358
Mechanically coupled resonators have been applied in the last years to the development of nanomechanical mass-sensors based on the detection of the different vibration modes of the system by measuring on a single resonator. Their sensitivity and capability for detecting multiple analytes strongly depends on the design and coupling strength between the mechanically coupled resonators in an array format. We present a theoretical and experimental study of the behavior of an asymmetrically coupled array of four different resonators. These doubly clamped beam resonators are elastically coupled by an overhang region of varying length along the transversal axis of the array. The results show that parameters such as the gap between microbeams and the overhang length affect the coupling strength, tuning the system from highly disordered and highly localized (weak coupling) to highly delocalized (strong coupling). In the strong coupling and partially localized case, the distances between resonant peaks are larger, reaching higher eigenfrequency values. In this case, relative changes in a specific eigenstate, due to an added mass, can be markedly large due to the energy distribution over a single microbeam. A strong coupling also facilitates performing the detection on the relative frequency shift mode, which can usually be resolved with better precision than the amplitude changes.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Effective ionic-liquid microemulsion based electrodeposition of mesoporous Co-Pt films for methanol oxidation catalysis in alkaline media

  • Serrà, Albert|||0000-0003-0147-3400
  • Gomez, Elvira|||0000-0002-9223-6357
  • Golosovsky, Igor V.|||0000-0002-2667-4711
  • Nogués, Josep|||0000-0003-4616-1371
  • Vallés, Elisa
Pt-based direct methanol fuel cells are attracting increasing interest as environmentally friendly alternative energy sources. However, the high price of Pt and the difficulty to prepare favourable morphologies for catalysis (e.g., mesoporous materials) are hampering their development into feasible products. Here, we demonstrate a novel approach to efficiently grow mesoporous films of Pt-poor alloys (CoPt and CoPt), based on electrodeposition in ionic liquid-in-water (IL/W) microemulsions. The high proportion of the electrolytic aqueous solution in the IL/W microemulsion favors a significant deposition rate, while the presence of IL drops induces the formation of highly mesoporous films. The mesoporous alloys, with pores in the 8-11 nm range, exhibit excellent durability in acidic and alkaline aggressive media, maintaining their peculiar morphology. The structures are very efficient for the catalysis of methanol electro-oxidation in alkaline media, with minimal poisoning of the catalysts. These results pave the way to develop simple, versatile environmentally friendly fuel cell catalysts to commercialize new viable ecological alternative energy sources.