DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación
Artículo científico (JournalArticle)
Simultaneous local heating/thermometry based on plasmonic magnetochromic nanoheaters
A crucial challenge in nanotherapies is achieving accurate and real‐time control of the therapeutic action, which is particularly relevant in local thermal therapies to minimize healthy tissue damage and necrotic cell deaths. Here, a nanoheater/thermometry concept is presented based on magnetoplasmonic (Co/Au or Fe/Au) nanodomes that merge exceptionally efficient plasmonic heating and simultaneous highly sensitive detection of the temperature variations. The temperature detection is based on precise optical monitoring of the magnetic‐induced rotation of the nanodomes in solution. It is shown that the phase lag between the optical signal and the driving magnetic field can be used to detect viscosity variations around the nanodomes with unprecedented accuracy (detection limit 0.0016 mPa s, i.e., 60‐fold smaller than state‐of‐the‐art plasmonic nanorheometers). This feature is exploited to monitor the viscosity reduction induced by optical heating in real‐time, even in highly inhomogeneous cell dispersions. The magnetochromic nanoheater/thermometers show higher optical stability, much higher heating efficiency and similar temperature detection limits (0.05 °C) compared to state‐of‐the art luminescent nanothermometers. The technological interest is also boosted by the simpler and lower cost temperature detection system, and the cost effectiveness and scalability of the nanofabrication process, thereby highlighting the biomedical potential of this nanotechnology., This work was supported by the Spanish Ministry of Economy, Industry and Competitivenes (MINECO) projects MAT2013‐48628‐R, MAT2016‐77391‐R, and PCIN‐2016‐093 (H2020 M‐ERA.NET). Z.L. acknowledges the Chinese Scholarship Council (CSC) Program (201506950059) for financial support. The 2017‐SGR‐292 project of the Generalitat de Catalunya is acknowledged. The ICN2 was funded by the Centres de Recerca de Catalunya (CERCA) programme/Generalitat de Catalunya. The ICN2 was supported by the Severo Ochoa programme (MINECO, No. SEV‐2013‐0295). A.L.‐O. and P.V. acknowledge funding from the Basque Government (No. PI2015_1_19), MINECO and the European Regional Development Fund (FEDER) (No. FIS2015 64519 R). A.L.‐O. acknowledges the support from Juan de la Cierva grant. This work was also supported by MINECO under the Maria de Maeztu Units of Excellence (MDM‐2016‐0618). J.S. acknowledges the financial support by the European Research Council (SPIN‐PORICS 2014‐Consolidator Grant, Agreement No. 648454)., Peer reviewed
Proyecto:
MINECO / Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016 MAT2013‐48628‐R
,
MINECO / Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016 MAT2016‐77391‐R
,
MINECO / Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016 PCIN‐2016‐093
,
EC / H2020 685451
,
MINECO / Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016 SEV‐2013‐0295
,
MINECO / Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016 FIS2015-64519-R
,
MINECO / Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016 MDM‐2016‐0618
,
EC / H2020 648454