Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Generation of defective few-layered graphene mesostructures by high-energy ball milling and their combination with FeSiCuNbB microwires for reinforcing microwave absorbing properties

  • López Sánchez, Jesús
  • Peña Moreno, Álvaro
  • Serrano, Aída
  • Del Campo, Adolfo
  • Rodríguez De La Fuente, Óscar
  • Carmona Tejero, Noemí
  • Matatagui Cruz, Daniel
  • Horrillo, María del Carmen
  • Rubio Zazo, Juan
  • Navarro Palma, Elena
  • Marín Palacios, María Pilar
Defective few-layered graphene mesostructures (DFLGMs) are produced from graphite flakes by high-energy milling processes. We obtain an accurate control of the generated mesostructures, as well as of the amount and classification of the structural defects formed, providing a functional material for microwave absorption purposes. Working under far-field conditions, competitive values of minimum reflection loss coefficient (RL_(min)) = −21.76 dB and EAB = 4.77 dB are achieved when DFLGMs are immersed in paints at a low volume fraction (1.95%). One step forward is developed by combining them with the excellent absorption behavior that offers amorphous Fe_(73.5)Si_(13.5)B_(9)Cu_(1)Nb microwires (MWs), varying their filling contents, which are below 3%. We obtain a RLmin improvement of 47% (−53.08 dB) and an EAB enhancement of 137% (4 dB) compared to those obtained by MW-based paints. Furthermore, a f_(min) tunability is demonstrated, maintaining similar RL_(min) and EAB values, irrespective of an ideal matching thickness. In this scenario, the Maxwell-Garnet standard model is valid, and dielectric losses mainly come from multiple reflections, interfacial and dielectric polarizations, which greatly boost the microwave attenuation of MWs. The present concept can remarkably enhance not only the MW attenuation but can also apply to other microwave absorption architectures of technological interest by adding low quantities of DFLGMs.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Real-Time Monitoring of Breath Biomarkers with A Magnetoelastic Contactless Gas Sensor: A Proof of Concept

  • Peña, Álvaro
  • Aguilera, Juan Diego
  • Matatagui, Daniel
  • Presa, Patricia de la
  • Horrillo, Carmen
  • Hernando, Antonio
  • Marín, Pilar
17 páginas, 12 figuras, 1 tabla, In the quest for effective gas sensors for breath analysis, magnetoelastic resonance-based gas sensors (MEGSs) are remarkable candidates. Thanks to their intrinsic contactless operation, they can be used as non-invasive and portable devices. However, traditional monitoring techniques are bound to slow detection, which hinders their application to fast bio-related reactions. Here we present a method for real-time monitoring of the resonance frequency, with a proof of concept for real-time monitoring of gaseous biomarkers based on resonance frequency. This method was validated with a MEGS based on a Metglass 2826 MB microribbon with a polyvinylpyrrolidone (PVP) nanofiber electrospun functionalization. The device provided a low-noise (RMS = 1.7 Hz), fast (<2 min), and highly reproducible response to humidity (Δf = 46–182 Hz for 17–95% RH), ammonia (Δf = 112 Hz for 40 ppm), and acetone (Δf = 44 Hz for 40 ppm). These analytes are highly important in biomedical applications, particularly ammonia and acetone, which are biomarkers related to diseases such as diabetes. Furthermore, the capability of distinguishing between breath and regular air was demonstrated with real breath measurements. The sensor also exhibited strong resistance to benzene, a common gaseous interferent in breath analysis., Author A.P. received funding from grant PRE2019-0875001234, Ministerio de Ciencia e Innovación (MCI), Spain. D.M. received funding from Comfuturo, Consejo Superior de Investigaciones Científicas, Spain. Authors A.P., D.M., P.M. and C.H. received funding from projects RTI2018-095856- B-C21 and RTI2018-095856-B-C22, Ministerio de Ciencia e Innovación, Spain. A.P. and P.M. received funding S2018/NMT-4321, Comunidad de Madrid. J.D.A received funding from Next Generation EU, Ministerio de Trabajo y Economía, Comunidad de Madrid, Spain, Programa Investigo from grant 96-UCM-INV.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Real-time monitoring of breath biomarkers using magnonic wireless sensor based on magnetic nanoparticles

  • Aguilera, J.D.
  • Arranz, D.
  • Peña, A.
  • Horrillo, Carmen
  • De la Presa, D.
  • Matatagui, D.
8 páginas, 6 figuras, In this paper, an innovative device with gas remote-sensing capability is proposed, which is based on the interaction between magnetic nanoparticles and gases associated with exhaled breath biomarkers that can have a metabolic origin. Magnetite (Fe₃O₄) nanoparticles of around 30 nm have been used. The gas molecules adsorbed on surface modulate the magnetization of the nanoparticles and magnetostatic surface spin waves (MSSW) propagated on an yttrium iron garnet (YIG) thin film are used to detect this modulation by the induced frequency shift. The optimization of the remote gas sensor has been carried out through simulations of a magnetic model. Simulations show the feasibility of developing a high-performance remote sensor by encapsulating the nano- structures in a polytetrafluoroethylene (PTFE) tube and detecting part per million changes in their magnetiza- tion. The results show the possibility of developing new, inexpensive, reusable, contactless magnetic gas sensors employing spin waves as transductor. The developed sensor shows a high sensitivity and selectivity to concen- trations as low as 50 ppm of different breath biomarkers., The authors acknowledge the Spanish Ministry of Science and Innovation for financing the projects RETOS RTI2018-095856-B, RTI2018-095856-B-C22 (AEI/FEDER), RTI2018-095856-B-C21 (AEI/FEDER), PID2021-123112OB-C21 (AEI/FEDER), PDC2022-133039-I00 (AEI/FEDER), Comunidad de Madrid (NANOMAGCOST-CM S2018/NMT-4321 and COST Action CA21101. J.D.A received funding from Next Generation EU, Ministerio de Trabajo y Economía, Comunidad de Madrid, Spain, Programa Investigo from grant 96-UCM-INV. D. M. acknowledges financial support from the Spanish Ministry of Science and Innovation (MCI) through the Ramóon y Cajal grant RYC2021-031166-I. A. P. acknowledges funding from grant PRE2019-0875001234 (MCI)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Beyond conventional characterization: Defect engineering role for sensitivity and selectivity of room-temperature UV-assisted graphene-based NO₂ sensors

  • Peña, Álvaro
  • López-Sánchez, Jesús
  • Sacco, Leandro
  • Vollebregt, Sten
  • Marqués-Marchán, Jorge
  • Horrillo, Carmen
  • Marín, Pilar
  • Matatagui, Daniel
10 páginas, 6 figuras, 1 tabla, The term graphene-based gas sensors may be too broad, as there are many physicochemical differences within the graphene-based materials (GBM) used for chemiresistive gas sensors. These differences condition the sensitivity, selectivity, recovery, and ultimately the sensing performance of these devices towards air pollutants. Continuous ultraviolet irradiation aids in the desorption of gas molecules and enhances sensor performance. Under these conditions, the devices from this work can reliably monitor NO2 and CO at room temperature, below the human-recommended exposure limits, presenting NO2 LoD down to ~20 ppb. By selecting GBMs with different levels of defectivity, which influence gas adsorption dynamics, and through comprehensive charac- terization, including D, D′, D″, 2D, and G Raman bands, graphene-based gas sensors can be tailored to meet specific sensing requirements. This study examines five different non-oxidized GBM to develop tools and gain a deeper understanding of the relationships between GBM properties and their sensing performance. This research introduces a new standard for defect assessment, moving beyond graphene’s D and G Raman band intensity ratio, to facilitate the successful integration of graphene-based gas sensors into everyday applications, such as envi- ronmental monitoring and industrial safety, and potentially impacting other 2D materials, thereby reducing health risks associated with air pollution., Author A. P. received funding from grant PRE2019-0875001234, Ministerio de Ciencia e Innovaci´on (MCIN), Spain. Authors A. P., D. M., P. M., and M-C. H. received funding from project PDC2022-133039- I00 and PID2021-123112OB-C21 from MCIN/AEI/10.13039/ 501100011033, Spain and European Union Next Generation EU/PRTR. D. M. acknowledges financial support from grant RYC2021-031166-I funded by MCIU/AEI/10.13039/501100011033. J. L.-S. acknowledges the financial support from PID2023-151036OA-I00 funded by MCIU/ AEI/10.13039/501100011033 and by the European Union, and from grant RYC2022-035912-I funded by MCIU/AEI/10.13039/ 501100011033 and by the European Social Fund Plus (ESF+). JM thanks the Regional Government of Madrid for the project P2018/NMT- 4321 NANOMAGCOST. M-C. H acknowledges the support from the COST Action CA21101, Peer reviewed